+ All Categories
Home > Technology > Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Date post: 25-May-2015
Category:
Upload: jon-zickermann
View: 359 times
Download: 0 times
Share this document with a friend
Description:
Undergraduate Research Project for Microsystems and Nanotechnology Minor
Popular Tags:
30
UNIVERSITY OF WISCONSIN-PLATTEVILLE GE4000 Project Report Static Force Activity in Nanofluidic Channels Jon Zickermann 12/14/2012 This project hopes to contribute to the progress that has been made in the field of nanofluidics. This report will take a look a set of nanofluidic channels. Surface topography will measured along with the forces and surface charges when the samples are submerged in water. Two methods of moving fluids will be considered – flow by pressure gradients and electroosmotic flow. To minimize pressure drop through a nanofluidic system, surface treatments should avoided where flow rate is the primary focus. For electroosmotic flow, fluorine surface would be optimal despite the rougher surface. Both surface treatments had regressions that appeared to be a combination of both the gold and plain glass surfaces.
Transcript
Page 1: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

University of Wisconsin-Platteville

GE4000 Project Report

Static Force Activity in Nanofluidic Channels

Jon Zickermann

12/14/2012

This project hopes to contribute to the progress that has been made in the field of nanofluidics. This report will take a look a set of nanofluidic channels. Surface topography will measured along with the forces and surface charges when the samples are submerged in water. Two methods of moving fluids will be considered – flow by pressure gradients and electroosmotic flow. To minimize pressure drop through a nanofluidic system, surface treatments should avoided where flow rate is the primary focus. For electroosmotic flow, fluorine surface would be optimal despite the rougher surface. Both surface treatments had regressions that appeared to be a combination of both the gold and plain glass surfaces.

Page 2: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Table of ContentsIntroduction.................................................................................................................................................2

Background..................................................................................................................................................2

Atomic Force Microscopy........................................................................................................................2

Equipment...........................................................................................................................................5

AFM Physics.........................................................................................................................................8

Nanofluidics.............................................................................................................................................8

Project Goals.............................................................................................................................................11

Results and Discussion...............................................................................................................................11

Surface Roughness................................................................................................................................11

Force Curves - SiNi Tip...........................................................................................................................13

Plain Glass..........................................................................................................................................13

Br Treated..........................................................................................................................................13

Fluorine Treated................................................................................................................................13

Force Curves – Spherical Tip..................................................................................................................14

Plain Glass..........................................................................................................................................14

Br Treated..........................................................................................................................................14

Fluorine Treated................................................................................................................................14

Force Curve Data...................................................................................................................................15

MATLAB Results.....................................................................................................................................15

Charge Density Regressions...................................................................................................................17

Conclusions................................................................................................................................................18

Acknowledgements...................................................................................................................................19

Appendix...................................................................................................................................................19

Plain Glass Surface Topography.............................................................................................................19

Br Surface Topography Images..............................................................................................................20

Fluorine Surface Topography Images....................................................................................................21

Force Curve Calibration Data.................................................................................................................23

Charge Density Distributions.................................................................................................................23

Works Cited...............................................................................................................................................24

Page 1 of 27

Page 3: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

IntroductionMicro and nanofluidics pose to greatly contribute to the fields of chemistry, physics and biology in the upcoming years. One example is in lab-on-a-chip systems, especially for mixing liquids at the nanoscale. As the field of nanofluidics matures, new ideas and concepts are being applied to lab-on-a-chip systems. The fundamental differences at the nanoscale physics in contrast with macroscale physics offer additional advantages to those devices that use nanopores or nanochannels. However,nanoscale physics and the effects on fluids have yet to be fully explored, especially in nanofluidics.

This project hopes to contribute to the progress that has been made in the field of nanofluidics. This report will take a look a set of nanofluidic channels fabricated and treated at The Ohio State University. Surface topography will measured along with the forces when the samples are submerged in water. The research was coordinated by Dr. Yan Wu and carried out by Jon Zickermann.

Background

Atomic Force MicroscopyAtomic Force Microscopes (AFMs) can allow imaging at the nanoscale which is beyond the limits of optical imaging, i.e., traditional optical microscopes. Conceptually, AFMs can be traced back to 1980s, specifically U.S. Patent 4,724,318by Gerd Binning (Seo & Jhe, 2007). AFMs use a microscopic technique imaging a surface topography by using attractive and repulsive interaction forces between a few atoms attached at a tip on a cantilever and a sample. In the case of attractive forces, there are three main contributions causing AFM. These are short-range chemical forces, van der Waals forces and electrostatic forces. As the effective ranges of these forces are different, one of them is dominant depending on distance.

van Der Waals interactions are based on the Coulomb interaction between electrically neutral atoms which are locally charged by thermal and/or quantum fluctuations. van Der Waals interactions are

governed byF=−A H R

6 z2, where AH is the Hamaker constant (typically 1eV), R is the radius of the

cantilever tip and z is the distance between the tip and the sample.Electrostatic forces are generated between a charged or conductive tip and sample which have a potential difference (V). This force is

governed by F=−π εoRV 2

z where εo is the dielectric constant. Additionally, ionic repulsion forces are

encountered at close ranges. As an atom approaches another atom, the electronic wave function will be overlapped and a very strong repulsion will be generated. This is also referred to as the Pauli exclusion. The last force of note is the capillary force, which is noticeable when a tip is close to the water layer, a liquid bridge called a meniscus is formed between the tip and the sample. This meniscus layer causes an attractive force (the capillary force) between the tip and the sample.

Page 2 of 27

Page 4: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

In this project, three modes of AFM were used: contact, tapping and force modes. The first two were used for surface roughness measurement, especially tapping mode. In contact mode, the probe (cantilever and tip) is scanned over the surface (or the sample is scanned under the probe) in an x-y raster pattern. The feedback loop maintains a constant cantilever deflection, and consequently a substantial, constant force on the sample. In contact mode, also referred to as AC mode, the probe also moves with a small vertical oscillation which is significantly faster than the raster scan rate. This leads to the force on the sample is modulated such that the average force on the sample is equal to that in contact mode.When the probe is modulated with the tip in contact with a sample, the sample surface resists the oscillation and the cantilever bends. The variation in cantilever deflection amplitude at the frequency of modulation is a measure of the relative stiffness of the surface.

Figure 1: Basic AFM Conceptual Operation (Geisse)

Page 3 of 27

Page 5: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Figure 2: Basic Contact vs. Tapping Mode (Wu, 2011)

Page 4 of 27

Page 6: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Figure 3: Summary of Forces with AFMs (JPK Instruments)

Page 5 of 27

Page 7: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Equipment

Atomic Force MicroscopeThe AFM used for the project is the MFP-3D-BIO by Asylum Research. The unit offers a 90x90µm range for scanning in the x and y axis with a 0.5nm resolution and a 5 µm Z axis range with a 0.25nm resolution. Vibration reduction uses theHerzanAVI-200 unit, capable of responding to undesired oscillations at 5-20ms(Asylum Research, 2009).

Figure 4: The MFP-3D-BIO (Asylum Research, 2009)

Figure 5: Active Vibration Filtering Unit(Herzan)

Cantilever Probes

Surface RoughnessProbesSurface roughness was measured using the basic budget tips used by most students using for classes (such as Chemistry 4520Nanoscale Characterization and Fabrication at University of Wisconsin - Platteville). The tips are shaped like a polygon based pyramid. Tip radii are typically around 7nm and height is 10-15μm.

Page 6 of 27

Page 8: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Figure 6: Dimensions of the Budget Tip Used

iDrive SystemForce curve measurement utilized the iDrive system. The iDriveNbFeB magnet is fully enclosed and sealed within the cantilever holder which allows for unobstructed bottom view of samples and prevents sample contamination. The iDrive system allows for probe actuation using electrical currents as show below:

Figure 7: Schematic diagram showing the Lorentz Force exerted onto the cantilever(Asylum Research)

Figure 8: iDrive Probe Holder

Page 7 of 27

Page 9: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

SiNi Triangular TipsTwo shapes of cantilevered tips were used for force curve measurement. The SiNItips are softer than the economical probes and are compatible for the iDrive system.

Lever Shape TriangularLever Thickness 0.4µmLever Width 13.4µmLever Length 100µmSpring constant (N/m) 0.09Resonant freq. (kHz) 32Tip shape 4-sided pyramidTip height 3µmTip radius <40nmTip angle <35° front

<35° sideCoating 40nm Au on tip side

50nm Au on reflex sideTable 1: Values for the SiNi Tip(Asylum Research)

Figure 9: SiNi Probe

Spherical TipsThe spherical tips, like the triangular SiNi tips, are softer than the standard probes. However, the spherical tip probes are gold-coated and offer a higher surface area than typical pyramid/cone shape tips.

Figure 10: Example of Spherical Tip AFM Probe (Interaction between fine particles)

Page 8 of 27

Page 10: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

AFM PhysicsTwo methods of determining the force measured by the probe are used by the software provide by Asylum Research: the thermal method and Sader method. Both methods differ by the method used to calculate the spring rate,k , used from the definition of Hooke’s Law F=kδ . The thermal method is used primarily in the project

The thermal method determines the spring rate as follows according to Asylum Research:

Figure 11: Thermal Method Calculations (Asylum Research)

The Sader method for a triangular tip determines the spring rate as:

k tri=D0d

2 L3 (1+ 4d3

b3 )−1

whered= d

√1+ b2

4 L2

,D 0=k rect4 L3

b,ℜ= ρωb2

4 η.

The MATLAB scripts will calculate the electrical charge and Debye length. The Debye length is effectively the distance where electrical charges have an effect. The Debye length for this experiment is defined as:

LD=√ ε0 εT k BT

2N A e2 I

where ε 0 is the permittivity of free space,ε Tis the dielectric constant, eis the elementary charge, I is the

ionic strength of the electrolyte, and N Ais the Avogadro constant(Debye Length, 2007), (Attard, 1996).

Page 9 of 27

Page 11: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Nanofluidics

NanophysicsNanofluidics is commonly defined as any liquid system where movement and control over liquids in or around objects with one dimension at most 100 nm. Others limit dimensions to 10-50nm at most (Mukhopadhyay, 2006).Nanofluidicsapplies to fluids inside nanoscale channels, porous alumina and nanoscale conduits. Currently, the primary application of nanofluidics is in lab-on-a-chip applications, specifically separation and analysis of DNA strands.Nanofluidics can also be utilized in diodes or field-effect transistors. However, the application of nanofluidics could eventually extend tosuch nanoscale systems like nanopumps, many of which are currently used at the larger microscale. Currently, nanophysics are still not fully understood. A table of the most common non-dimensional constants that can be used to characterize micro and nanoscale physics for fluids is as follows:

Table 2: Common Nondimensional Constants (Oosterbroek, 1999), (Eijkel & van den Berg, 2005)

The biggest difference between macroscale fluid dynamics and micro and nanoscale fluid mechanics is the effects due to very low Reynolds numbers. At the micro and nanoscale, surface tension dominates and the no-slip condition which is assumed at the macroscale does not apply.The greater amount of slip favors more efficient flow.

Figure 12: No-slip Assumption versus Slip Flow (Boundary slip and nanobubble study in micro/nanofluidics using atomic forcemicroscopy, 2009)

Two primary methods of fluid transport for micro and nanofluidics are utilized to move fluids: pressure gradients and voltage potentials (electroosmotic flow). For flow by pressure gradients, velocity can be calculated as follows:

Page 10 of 27

Page 12: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

V⃗= h2

12η (−dPdx )(1+ 6bh )

assuming the width of the channel is much greater than height. Here, η is the fluid viscosity, b is the

critical unit of length and dPdx

is the pressure gradient. It should be noted that the term 6bh

is the

contribution due to the slip condition. For electroosmotic flow, the charactering equation is:

V=−ϵξEη (1+ b

LD ) V 0

ξ

wherebLD

and V 0

ξ are contributions due to the slip condition and

ϵξEη

is the contribution from the

Helmholtz-Smoluchowsky velocity(Eijkel J. , 2007).

Nanofluidics offer many advantages for some applications and disadvantages if used in the improper systems. Scaling down microfluidic systems down to nanofluidic sizes offers the possibility to confine molecules to very small spaces and subject them to controlled forces. Additionally, there is the potential for precise control of liquid flow and molecular behavior at the nanoscale. However, nanofluidic systems are harder to fabricate compared to microfluidic counterparts. Additionally, there is a higher tendency for channels to get clogged and lower signal quality when trying to send voltages.

Figure 13: Example Difference Between Nano and Micro Channels (Daiguji, 2009)

NanofabricationSince the field of nanofluidics is years away from maturation, there is no standard method of fabrication for nanofluidic devices. As with most micro and nanodevices, fabrication can be described by either top-down or bottom-up methods. Building a nanofluidic device using top-down methods is accomplished from using photolithography methods on a substrate silicon wafer, which is how most Micro electromechanical systems (MEMS) devices are fabricated. From the top-down methods, nanofluidic

Page 11 of 27

Page 13: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

devices can be integrated on a MEMS chip on one wafer. Traditional top-down methods offer an economical method to nanofluidic device fabrication. For bottom-up techniques, self-assembled monolayers (SAMs) can be used with biological materials to form a molecular monolayer on the substrate. Additionally, carbon nanotubes (CNTs) offers an alternative, however, this method is still in development and is years away from any nanofluidic applications. While not as economical, bottom-up methods can precise shapes at the nanoscale.

Project GoalsMultiple objectives were outlined at the start of the project. The first was to understand the operation principle of dynamic AFM imaging and static force curve measurements. The next objective is to learn the impact of surface treatment of micro-nanofluidic channel wall on slip flow and electrokinectic flow. Another goal is to perform surface topography measurements and surface roughness measurements using AFM inside nanofluidic channels. These samples are nanochannels of depths of 80, 250 and 450nm. One set of nanochannels were treated with bromine and another set treated with fluorine by ShauryaPrakash at The Ohio StateUniversity. The next goal is to prepare an electrolyte solution with different pH and concentration. Finally, static force curve activity at the nanofluidic channel wall in electrolyte solutions will be measured. Basic adhesion forces can be calculated from the built-in software supplied by Asylum Research. The electrical charges and the level of charge versus distance from substrate surface will be calculated using a program written by Dr. Yan Wu.

Figure 14: Example Graphs to be Created (Wu, 2011)

If time does not allow, data will be calculated from only deionized water where the pH level is 6.0.

Results and Discussion

Surface RoughnessThe values calculated from the AFM software were taken at three points. The design of the nanochannel resembled a “Y” shape when observed from the top. The three points were taken at each “leg” at approximately the same location for each sample. The AFM scans were ran at approximately 0.20 to 0.40Hz for maximum accuracy and feedback precision. Scans that calculated surface RMS values

Page 12 of 27

Page 14: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

that appeared to be outliers were rejected and, if possible, rescanned with the probe recalibrated or repositioned.

80nm 250nmPlain 0.950 1.314Br 1.607 1.485F 4.926 4.615

Table 3: Average Surface Roughness RMS Values in Nanometers

80nm 250nm 450nm0.0

1.0

2.0

3.0

4.0

5.0

Nanochannel Comparison

PlainBrF

Channel DepthAver

age

Surf

ace

Roug

hnes

s RM

S (n

m)

Figure 15: Visual Comparison of Surface RMS Values by Channel Depth

0.00.51.01.52.02.53.03.54.04.5

Nanochannel Comparison

PlainBrF

Average Sample Values

Aver

age

Surf

ace

Roug

hnes

s RM

S (n

m)

Figure 16: Average Sample Values

Page 13 of 27

Page 15: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Force Curves - SiNi Tip

Plain Glass

Br Treated

Fluorine Treated

Page 14 of 27

Page 16: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Force Curves – Spherical Tip

Plain Glass

Br Treated

Fluorine Treated

Page 15 of 27

Page 17: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Force Curve DataAs state before, average surface attraction forces can be calculated from the Asylum Research. Using a continuous scan, multiple samples can be acquired with relative ease, allowing eliminating outliers. Additionally, the same data can be used for MATLAB calculations.

Table 4: Force data from SiNi Tip

µ (nN) σ (nN)Plain 27.60 0.0249Br 18.05 0.0019F 15.33 2.7500

Table 5: Force data from Spherical Tip

MATLAB Results

Plain Br F Gold10

100

1000

Debye length

Leng

th (n

m)

Page 16 of 27

µ (nN) σ (nN)Plain 6.30 0.078Br 21.97 0.405F 1.06 0.144

Page 18: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Plain Br F Gold0.000

0.001

0.002

0.003

0.004

0.005

0.006

0.007

Charge Density

Char

ge D

ensit

y (C

/m^2

)

Page 17 of 27

Page 19: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Charge Density Regressions

Plain Surface

Br Surface

Fluorine Surface

Page 18 of 27

Page 20: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Gold Surface

ConclusionsSurface topography scans reveal that treatments increase the roughness of the nanochannels, especially fluorine solutions, which on average had a 4nm increase in RMS value in surface roughness. These conclusions can bedetermined by visual inspection of the images generated from the AFM, where the bumps on the surface appear smoother on the untreated samples compared to the rough edges common to the surfaces of the fluorine treated samples.Therefore, to minimize pressure drop through a nanofluidic system, surface treatments should avoided where flow rate is the primary focus and pressure drop needs to be minimized.

Force measurement scans with the triangular tip reveal that bromine treatment produces a positive charge buildup that strongly attracts electrical charges, whereas fluorine treatment produces a repulsive force that resisted the cantilever tip. The same scans ran with the spherical tip indicate that the attraction forces are stronger. These increases can be attributed to the larger surface area which allows for more charges to build on the tip surface. The plain surface sample attraction force is stronger than any other force, spherical or triangular tip.

Information from the MATLAB tells more about the force modulation from the AFM. Untreated, the charge distribution is virtually identical to the typical models, as expected. This offers a template to compare the other samples against. Inspection of the charts created by Excel show that the charges in the bromine treated surface reach far from the substrate surface as indicated by the large Debye lengths. This is consistent to the force curves generated by the AFM software, where the cantilever probe “jumped in” to the surface substrate at a faster rate than any other surface treatments. The fluorine surface has a large concentration of charges near the surface, however, compared to the plain and bromine treated surfaces, the charges are repelling them. For electroosmotic flow, fluorine surface would be optimal despite the rougher surface.Both surface treatments had regressions that appeared to be a combination of both the gold and plain glass surfaces.

Page 19 of 27

Page 21: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

AcknowledgementsThe author wishes to thank Dr. Yan Wu for her patience and help on this project. Additionally, help from peers doing research in the University of Wisconsin - Platteville cleanroom was very nice in helping the author start his research in the early days in this project. Finally, the author would like to recognize Dr. MichealMomot for allowing the author to share a cleanroom key for easy access to the University of Wisconsin - Platteville cleanroom.

Appendix

Plain Glass Surface Topography

Page 20 of 27

Page 22: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Br Surface Topography Images

Page 21 of 27

Page 23: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Fluorine Surface Topography Images

Page 22 of 27

Page 24: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Page 23 of 27

Page 25: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Force Curve Calibration Datak (mN/m) Q Freq (kHz)

Plain 83.32 15.2 31.267Br 87.26 15.2 30.947F 85.29 15.3 30.733

Table 6: Air Calibration Data for SiNi Tip

k (mN/m) Q Freq (kHz)Plain 87.34 25.0 21.336Br 84.82 25.1 21.319F 89.85 24.9 21.568

Table 7: Air Calibration Data for Spherical Tip

Charge Density Distributions

Plain Surface

Br Surface

Page 24 of 27

Page 26: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Fluorine Surface

Gold Surface

Works CitedDebye Length. (2007, January 22). Retrieved December 19, 2012, from Duke University:

http://people.duke.edu/~ad159/files/p142/2.pdf

Boundary slip and nanobubble study in micro/nanofluidics using atomic force microscopy. (2009, November 28). Soft Matter, pp. 29-66.

Asylum Research. (2009, August 12). MFP-3D AFMs - Extensive Suite of System, Environmental, and Application Options Enabling Users to Broaden AFM Capabilities by Asylum Research. Retrieved December 16, 2012, from A to Z Nano: http://www.azonano.com/article.aspx?ArticleID=2343

Asylum Research. (n.d.). iDrive™ Magnetic Actuated Cantilever . Retrieved from Asylum Research: http://www.asylumresearch.com/Products/iDrive/iDrive.shtml

Asylum Research. (n.d.). The Physics of Atomic Force Microscopy. Retrieved December 2012, from Asylum Research: http://www.asylumresearch.com/Applications/EquationCard.pdf

Page 25 of 27

Page 27: Ge4000 report - Static Force Curve Activity in Nanofluidic Channels

Attard, P. (1996). Electrolytes and the Electric Double Layer. Adv. Chem. Phys.

Daiguji, H. (2009, July 1). Ion transport in nanofluidic channels. Chemical Society Reviews, pp. 903-913.

Eijkel, J. (2007). Liquid Slip in Micro-and Nanofluidic: Recent Research and its Possible Implications. Lab-on-a-Chip, pp. 299-301.

Eijkel, J. C., & van den Berg, A. (2005, April 8). Nanofluidics: what is it and what can we expect from it? pp. 249-267.

Geisse, N. (n.d.). AFM and Combined Optical Techniques. Retrieved December 16, 2012, from Asylum Research: http://tinyurl.com/asylumresearchafm

Herzan. (n.d.). Active Vibration Control - TS Series . Retrieved December 17, 2012, from Herzan: http://www.herzan.com/products/active-vibration-control/ts-series.html#TS%20MODELS

Interaction between fine particles. (n.d.). Retrieved December 2012, from http://www.mpip-mainz.mpg.de/documents/akbu/pages/particles.htm

JPK Instruments. (n.d.). A Pratical Guide to AFM Force Spectroscopy and Data Analysis. JPK Instruments.

Mukhopadhyay, R. (2006, November 1). WHAT DOES NANOFLUIDICS HAVE TO OFFER? PLENTY, SAY EXPERTS. Analytical Chemisty, pp. 7380-7382.

Oosterbroek, E. (1999). Modeling, design and realization of microfluidic components.

Seo, Y., & Jhe, W. (2007, December 17). Atomic force microscopy and spectroscopy. REPORTS ON PROGRESS IN PHYSICS, pp. 71-94.

Wu, Y. (2011). Advanced AFM. Plattevile, WI.

Page 26 of 27


Recommended