2
Components, options and accessories Mounting the equipment/ Adaptation plate Dimensions/Free space Electrical power connection ITEM DESCRIPTION DIMENSIONS A EQUIPMENT LENGTH 587 mm B EQUIPMENT WIDTH 341 mm C EQUIPMENT HEIGHT 481 mm D EQUIPMENT HEIGHT WITH AUTOMATIC FEEDER (APPROX.) 577 mm E EQUIPMENT LENGTH WITH ELECTRICAL CABINET OPEN 838 mm LN ~ 230V 50 Hz + PE 3N ~ 400V/230V 50 Hz + PE EQUIPMENT No. OUTPUT 1 PHASE 3 PHASES 230 VAC 400 VAC Y Micron MOD 2 21.39 A 10.95 A 4 31.82 A 10.95 A 6 42.26 A 15.65 A 2 Ø6-12mm ITEM A 92 mm B -- C 381 mm D 571 mm E 49 mm F 249 mm G 334 mm M8 M8 D E A G F B C B Meler Gluing Solutions, S.A P.I. Los Agustinos, calle G, nave D-43 E - 31160 ORCOYEN Navarra (España) Tel.: + 34 948 351 110 Fax: + 34 948 351 130 e-mail: [email protected] www.meler.eu GLUING SOLUTIONS Fitting straight short Warning light VP system Low level detector Adaptation plate Hose Automatic feeder E A C D 3 L3 N PE L1 L2 L3 N PE LN ~ 230V 50 Hz + PE 3N ~ 400V/230V 50 Hz + PE Pneumatic and hose connection P= 0 bar 1 9/16“ 6 x 1 3 5 2 4 6 3 Ø8mm Ø10mm P max = 6 bar 2 1 3 5 2 4 6 4 Note: Both the air supply intake of the equipment such as air supply to the solenoid valve of the automatic feeder must be different. QUICK START GUIDE: MICRON MOD Warning: Risk of electrical shock. Carelessness may produce injury or death. Warning: Hot zone with high temperatures. Risk of burns. Use thermal protective equipment. Warning: System under pressure. Risk of burns or particle projection. Use thermal protective equipment and googles. Warning: Important information for the correct use of the system. May include one or several of the previous hazards, and therefore must be kept in mind to avoid damage and injury. Warning: The micron MOD melters are equipment with current technology and with certain foreseeable risks. Therefore, only allow qualified personnel with sufficient training and experience to use, install or repair this equipment. In case of doubts in the moment of installation, refer to the corresponding instructions manual. If you want this guide in other language, see the website: http://www.meler.eu/Products/manuals-documentation.aspx M8 M8 1
Transcript
Page 1: Guía puesta en marcha rápida serie micrón mod ENG

Components, options and accessories

Mounting the equipment/ Adaptation plate

Dimensions/Free space

Electrical power connection

ITEM DESCRIPTION DIMENSIONSA EQUIPMENT LENGTH 587 mm

B EQUIPMENT WIDTH 341 mm

C EQUIPMENT HEIGHT 481 mm

D EQUIPMENT HEIGHT WITH AUTOMATIC FEEDER (APPROX.)

577 mm

E EQUIPMENT LENGTH WITH ELECTRICAL CABINET OPEN 838 mm

LN ~ 230V 50 Hz + PE3N ~ 400V/230V 50 Hz + PE

EQUIPMENT No. OUTPUT 1 PHASE 3 PHASES230 VAC 400 VAC Y

Micron MOD 2 21.39 A 10.95 A4 31.82 A 10.95 A6 42.26 A 15.65 A

2

Ø6-12mm

ITEMA 92 mmB --C 381 mmD 571 mmE 49 mmF 249 mmG 334 mm

M8M8

MATERIAL/MATERIAL

TRATAMIENTO/TREATMENT

VALIDADO/COMFIRMDIBUJADO/DESIGN

NOMBRE/NAME

FECHA/DATE

TITULO/TITLEESCALA/SCALE

REFERENCIA/REFERENCE

SUS. A/REPLACES

CATEGORIA/RATE

DENOMINACION/DENOMINATION

HOJA Nº/SHEET NUMBER

C.T.B.

11/10/2011

201020160

CHASIS MICRON 10 PISTON 20132 de 2

Este plano es propiedad exclusiva de MELER APLICADORES DE HOT - MELT S.A. Todos los derechos reservados. This drawing is owned sole of MELER APLICADORES DE HOT- MELT S.A. All rights reserved.

DPTO. OFICINA TECNICA

REV./

REV.

-----

------

D

E

A

G F

B C

B

Meler Gluing Solutions, S.AP.I. Los Agustinos, calle G, nave D-43E - 31160 ORCOYEN Navarra (España)Tel.: + 34 948 351 110 Fax: + 34 948 351 130e-mail: [email protected] www.meler.eu

GLUING SOLUTIONS

Fitting straight short

Warning lightVP system

Low level detector

Adaptation plate

Hose

Automatic feeder EA

C

D

3

L3 N PE L1 L2 L3 N PE

LN ~ 230V 50 Hz + PE 3N ~ 400V/230V 50 Hz + PE

Pneumatic and hose connection

P= 0 bar 1

9/16“

6 x1 3 5

2 4 6 3

Ø8mm

Ø10mm

Pmax= 6 bar

2

1 3 5

2 4 64

Note: Both the air supply intake of the equipment such as air supply to the solenoid valve of the automatic feeder must be different.

QUICK START GUIDE: MICRON MOD

Warning: Risk of electrical shock. Carelessness may produce injury or death. Warning: Hot zone with high temperatures. Risk of burns. Use thermal protective equipment. Warning: System under pressure. Risk of burns or particle projection. Use thermal protective equipment and googles. Warning: Important information for the correct use of the system. May include one or several of the previous hazards, and therefore must be kept in mind to avoid damage and injury.

Warning: The micron MOD melters are equipment with current technology and with certain foreseeable risks. Therefore, only allow qualified personnel with sufficient training and experience to use, install or repair this equipment.

In case of doubts in the moment of installation, refer to the corresponding instructions manual. If you want this guide in other language, see the website: http://www.meler.eu/Products/manuals-documentation.aspx

M8M81

Page 2: Guía puesta en marcha rápida serie micrón mod ENG

Control board

External I/O connections (optional)

Automatic feeder pneumatic connection Connecting the suction tube

Placing the suction tube Introduce the suction tube in the adhesive container.

Connecting control detectors Both detectors are wired in the electrical cabinet.

Starting up the melter equipment

Note: To adjust the programmable times using the timer refer to chapter 4 of the corresponding instructions manual.

8

12

11

9

3

10

7

6

4 5

1. Tank indicator LED 2. Hose indicator LED 3. Gun indicator LED 4. Temperature set point 5. Actual temperature 6. ON/OFF switch 7. Standby function 8. Temperature OK LED and active pump 9. Time scheduling 10. Left/right button - channel selection 11. Up/down button - temperature modification

1 6 01 6 0

1 5 01 5 0

1 2 3 4 5 6 7 8

CN 5Control card

1 common and voltage out + 2 input for inhibitor output 1 3 input for inhibitor output 2 4 input for inhibitor output 3 5 input for inhibitor output 4 6 input for inhibitor output 5 7 input for inhibitor output 6 8 without connection

OUTPUT DISABLE

Valores por defecto

LED DISPLAY COMPONENT HEATING COMPONENT STATUS

constantly lit constant low temperature

blinking slowly as need (according to PID parameters) temperature near set point

blinking rapidly programming or display change in set point values

off not heating temperature reached

On/Off

1

2

P pneumatic P hydraulic

Ratio 1:13,6

2

Ø4-8mm

Temp. OK

1. If it does not have a pressure regulator (PR): 2. If it does have a pressure regulator (PR):

2

1

Ø10 mm

Ø10 mmINLET

OUTLET

2 1Ø10 mm Ø10 mm

INLETOUTLET

3 Ø10 mmConnect 2 and 3

2

3

1 Loosen slightly the three fixing screws indicated counterclockwise.

Place the swievel elbow to the desired position.

Tighten the three fixing screws to the position of the elbow clockwise.

LOAD DETECTOR

CLOSED LID DETECTORYellow button: reset equipment Black button: reset acoustic signal

-- - 5 5

-- - 1 0

º C

Selecting the overheating value/ Standby Temperature adjustment

Return to initial parameter

Select the element

Modify temperatureNext display to record the value:

Next display to record the value:

Below of 40ºC, temperature display and heating OFF

Tank’s set point Tª value by default

For more information about the different functions of the control board, refer to the corresponding instructions manual.

3

1

2

4

o f f 4 0 º C

1 6 0 1 6 0

OVERHEATING 10< Increase Tª < 25

STANDBY

25< Decrease Tª % < 55

1

1


Recommended