+ All Categories
Home > Documents > High Speed Links

High Speed Links

Date post: 12-Jan-2016
Category:
Upload: jase
View: 64 times
Download: 0 times
Share this document with a friend
Description:
High Speed Links. F. Vasey, CERN, PH-ESE. High speed links in LHC and commercial applications On-going common projects for LHC Phase I upgrades Towards HL-LHC Conclusions. 1. High Speed Links in LHC. Trigger. Timing/triggers/ sync. Control/monitoring. Switching network. CPU. - PowerPoint PPT Presentation
Popular Tags:
23
2 October 2013 [email protected] 1 High Speed Links 1. High speed links in LHC and commercial applications 2. On-going common projects for LHC Phase I upgrades 3. Towards HL-LHC 4. Conclusions F. Vasey, CERN, PH-ESE
Transcript
Page 1: High Speed Links

[email protected] 12 October 2013

High Speed Links  

1. High speed links in LHC and commercial applications2. On-going common projects for LHC Phase I upgrades3. Towards HL-LHC4. Conclusions

F. Vasey, CERN, PH-ESE

Page 2: High Speed Links

[email protected]

1. High Speed Links in LHC

22 October 2013

CPU

CPU

CPU

CPU

CPU

CPU

Switching network

Front-end DAQ interfaceFront-end DAQ

interfaceFront-end DAQ interfaceFront-end DAQ

interface 1

Front-end DAQ interface N

Front-end DAQ interface 2

Timing/triggers/sync Control/monitoringTrigger

Page 3: High Speed Links

[email protected]

1.1 Many different Link types Readout - DAQ:

Unidirectional Event frames. High rate Point to point

Trigger data: Unidirectional High constant data rate Short and constant latency Point to point

Detector Control System Bidirectional Low/moderate rate (“slow

control”) Bus/network or point to

point Timing: Clock, triggers,

resets Precise timing (low jitter

and constant latency) Low latency Fan-out network

(with partitioning)

3

Different link types remain physically separate, each with their own specific implementation

2 October 2013

Page 4: High Speed Links

[email protected]

1.2 For instance: Links in ATLAS

42 October 2013

Detector Purpose Media Dir. Rate Mbits/s

Quantity Comment

Pixel TTC/DCS/DAQ

Optical Down/up

40 (80) 250 Custom

SCT TTC/DCS/DAQ

Optical Down/up

40 8200 Custom

TRT TTC/DCS LVDS-Cu

Down 40 400 Custom

DAQ/DCS LVDS – Optical

Up 40 –1600 400 GOL

Ecal TTC Optical Down 80 TTC link

DCS LVDS-Cu

Down/Up

SPAC

DAQ Optical Up 1600 1600 Glink

Trigger Copper

Up Sub-det. Analog

Hcal TTC Optical Down 80 TTC link

DCS Copper

Down/up

CAN

DAQ Optical Up 1600 512 Glink

Trigger Copper

Up Analog

CSC, RPC, TGC DAQ Optical Up 1600 1200 Glink

MDT DAQ Optical Up 1600 1200 GOL

CSC TTC Optical Down 1600 200 Glink

CSC, RPC, TGC, MDT

DCS Copper

Down/up

CAN

RPC Trigger Optical Up 1600 Glink

Page 5: High Speed Links

[email protected]

1.3 For instance: Links in CMS

52 October 2013

Detector Purpose Media Dir. Rate Mbits/s

Quantity Comment

Pixel - strip TTC/DCS Optical Down/up

80 3.250 CCU, Custom

DAQ Optical Up 40Msamp~320

40.000 Custom analog

Ecal TTC/DCS Optical Down/up

80 3.000 CCU, Custom

DAQ Optical Up 800 3.000 GOL

Trigger Optical Up 800 5.300 GOL

Hcal TTC Optical Down 80 160

DCS Electrical

Down/up

n/a 160

DAQ & Trig Optical Up 1600 2.000 GOL

Muons TTC Optical Down 80 240 DT

DCS Optical Down/up

80 150 RPC

DAQ Electrical

Up parallel 800 DT

Trigger Optical Up 1.600 600 RPC

Trigger Electrical

Up parallel 800 DT,CSC

Page 6: High Speed Links

[email protected] 62 October 2013

1.4 High Speed Optical Links in LHC

Large quantity o(100k), large diversity Majority running @ o(1Gbps) From full custom to qualified COTS

Tuned to specific application and environment Developed by independent teams

Successful adoption of technology in HEP

Page 7: High Speed Links

[email protected] 72 October 2013

1.5 High Speed Links in LHC: Lessons Learned

Increase Link Bandwidth amortize system cost better

Share R&D effort use limited resources optimally

Strengthen quality assurance Programs Identify problems early Test at system level

Joint ATLAS/CMS NOTE ATL-COM-ELEC-2007-001

CMS-IN-2007/066 https://edms.cern.ch/document/882775/3.8

Page 8: High Speed Links

[email protected] 82 October 2013

1.6 High Speed (short distance) Links outside LHC

Rapid progress driven by: Successful standardization effort

100 GbE standard ratified in 2010 by IEEE Availability of hardware cores embedded in FPGAs

50+ x 10G transceivers in modern FPGAs Commercial availability of MSA-based hardware

Commodity 10G and 40G devices Emerging 100G and 400G engines

Current LAN rates @ o(10Gbps), ramping up to 40Gbps

Widening performance gap compared to HEP But consider:

Specific environmental constraints Long development time: vintage 2000 hardware in LHC

Page 9: High Speed Links

[email protected] 92 October 2013

2. On-going Development Projects for LHC Phase I Upgrades

Initially aiming at a single SLHC target Launched in 2008 Timely developments for phase I upgrades

Working Groups Microelectronics User Group (MUG) Optoelectronics Working Group (Opto WG)

Common Projects Rad Hard Optical Link

GigaBit Transceiver (GBT) project (chip-set) & GBT-FPGA project

Versatile Link (VL) project (opto) & Gigabit Link Interface Board (GLIB)

Many others …

Page 10: High Speed Links

[email protected] 102 October 2013

2.1 Rad Hard Optical Link Common Project

Requirements: General

Bi-directional High data rate: 4.8Gbits/s Low and constant latency (for TTC and trigger data paths) Error detection and correction

Environment Radiation hard ASICs (130nm) and radiation qualified opto-electronics at

Front-End Magnetic Field tolerant devices at Front-End Flexible chip interface (e-links) to adapt to various architectures Compatibility with legacy fibre plants

Back-end COTS High-end FPGAs with embedded transceivers

GBT-FPGA firmware Parallel optics

Commitment to deliver to ATLAS, CMS and LHCb in 2014-2015

Page 11: High Speed Links

[email protected] 11

2.2 Impact on System Architecture Custom development for

difficult Front-End Firmware only for COTS-

based Back-End Evaluation platform for

system-tests

CPU

CPU

CPU

CPU

CPU

CPU

Switching network

Front-end interface

Front-end interface

Front-end interface

Timing/triggers/sync

Control/monitoring

Trigger

DCS network

Rad-hard optical links

2 October 2013

Page 12: High Speed Links

[email protected] 122 October 2013

2.3 GBT Project Status Project started in 2008

GBT (Serializer/Deserializer) 1st iteration (GBT-Serdes) in

2009 2nd iteration (GBTx) in 2012 Packaging in 2013 3rd iteration and prod in 2014

GBLD (Laser Driver) Final iteration (V4.1/V5) in 2013

GBTIA (Pin Diode Receiver) Final iteration (V3) in 2012

GBTSCA (Slow Control ASIC) Final version expected in 2014

GBT-FPGA firmware Available Tracking major FPGA families

Project delivers Chipset for Front-End GBT-FPGA Back-End firmware

Page 13: High Speed Links

[email protected] 132 October 2013

2.4 VL Project Status Kick-off: April08 Proof of concept: Sep09 Feasibility demo: Sep11 Project delivers

Custom built Rad Hard VTRx Production readiness: Apr14 Early delivery of rad-soft VTTX to

CMS-Cal-Trig: Dec13 Recommendations for

Fibre and connectors Backend optics

Evaluation Interface boards (GLIB) Experiments

Design their own system Select passive and backend components

based on VL recommendations and on their own constraints

Page 14: High Speed Links

[email protected] 14

2.5 Packaging and Interconnects Status

GBT 20x20 BGA with on-

package crystal and decoupling capacitors

CERN<>IMEC<>ASE 5 iterations to freeze

design 1-4 weeks per iteration 6 months to first prototype Mask error, re-spin,

+2months

VL High speed PCB simulation

and design Injection-moulded ULTEM

2xLC connector latch and pcb support

Prototyping started 2009, moulded parts delivered 2013

2 October 2013

Page 15: High Speed Links

[email protected] 152 October 2013

2.6 Rad Hard Optical Link Project Effort

6 years of development Launched in 2008 Delivery in 2014-15

6 institutes involved CERN, FNAL, IN2P3, INFN, Oxford, SMU Estimated 80 MY + 2-3 MCHF development

effort

Page 16: High Speed Links

[email protected] 162 October 2013

3. Towards HL-LHC

Higher Data-rate Lower Power Smaller Footprint Enhanced Radiation Resistance

Not to be forgotten: Fast electrical links Radiation-soft links

Not all in same link

Page 17: High Speed Links

[email protected] 172 October 2013

3.1 Higher Data-Rate and Lower Power

Requires migrating to a more advanced technology node: 65nm

Qualify technology Establish stable support framework and design tools for full

duration of development Design new ASICs taking advantage of technology

Either high speed (multiply by two) Or low power (divide by four)

VL Opto components 10G capable But will need to qualify new emerging components

Electrical interconnects and packaging become performance limiters

Build up expertise Train with relevant simulation and design Tools Establish relationships with selected suppliers

Page 18: High Speed Links

[email protected] 182 October 2013

3.2 Smaller Footprint

GBT package size can be shrunk by limiting the number of IO pads and going to fine pitch BGA

Will affect host board design

VTRx concept has been pushed to its size limit: SF-VTRx

Not sufficient for some tracker layouts

Tracker frontends will need custom packaging

Industry to be approached

VTRx

SF-VTRx

Page 19: High Speed Links

[email protected] 192 October 2013

3.3 Enhanced Radiation Resistance

ASICs likely to be OK

Active opto devices tested up to now do not resist fluences beyond 1016 cm-2

Still OK for HL-LHC Tk, not for pixels

Tight margins Are there

alternatives for fluences beyond 1016 cm-2 ?

Reconsider Passives?

modulators

Tx

Rx

HL-LHC TK

HL-LHC TK

Page 20: High Speed Links

[email protected] 202 October 2013

3.4 Si-Photonics, a paradigm changing technology?

Si is an excellent optical material with high refractive index (but indirect

bandgap) Is widely available in high quality grade Can be processed with extreme precision using deep submicron CMOS

processing techniques So, why not build a photonic circuit in a CMOS Si-wafer?

Page 21: High Speed Links

[email protected] 212 October 2013

3.5 Si-Photonics, status in the community

Commercial devices tested at CERN and ANL

Excellent functional performance Moderate radiation resistance

limited by controller ASIC failure On-going collaborations with

one academic and two industrial partners

Simulation tools in hands Selected building blocks

under test No usable conclusion so far,

much more work needed Packaging is challenging

Assess radiation hardness first ! Luxtera QSFP+ Si-Photonics chip

Page 22: High Speed Links

[email protected] 222 October 2013

3.6 Not to be forgotten

Fast electrical data links are not obsolete !!! Short distance, on-board serial links Aggregation to high speed opto-hubs Very high radiation fields (HL-LHC pixels) Develop expertise and tools

Detectors with modest radiation levels may not need custom front-ends Qualify COTS and/or Radiation-soft components Shortlist recommended parts Continuously track market evolution

Page 23: High Speed Links

23

4. Conclusions High speed links are the umbilical cord of the experiments Meeting the HL-LHC challenge will require:

Qualifying new, emerging technologies Designing electronics, interconnects, packages and perhaps even

optoelectronics Maintaining expertise, tools and facilities Investing with a few selected industrial partners

The community is healthy, but small and fragmented Working groups and common projects put in place for phase I

upgrades are effective and should be continued in phase II Additional projects and working groups could be created

WG on fast electrical links & signal integrity, and radiation-soft links Project on Si-photonics for HEP applications

Manpower is the real bottleneck, time is the contingency Development time remains very long

6 years, 6 institutes, 80 MY were required to reach production readiness for phase I

Widening gap with industry

Development

Service

Commercial liaison

Design

Common projects

Working groups

People


Recommended