Solutions throughout the world
United KingdomBabcock Wanson UK
7 Elstree Way - Borehamwood Hertfordshire WD6 1SA (UK)Tel: (44) (0) 20 8953 7111 - Fax: (44) (0) 20 8207 5177 - E-mail: [email protected]
FranceBabcock Wanson
106-110 rue du Petit-le-Roy 94550 Chevilly-Larue (France)Tel: 01 49 78 44 00 - Fax: 01 46 86 14 16 - E-mail: [email protected]
ItalyBabcock Wanson Italiana
Via Roma 147 – 20040 Cavenago Brianza-Milano (Italy)Tel: (39) 02 959 121 - Fax: (39) 02 950 192 52 - E-mail: [email protected]
MoroccoBabcock Wanson Maroc
Piste d’Aïn Bordja - Aïn Sebaa 21600 Casablanca (Morocco)Tel: (212) 22 35 23 47 - Fax: (212) 22 35 23 09 - E-mail: [email protected]
PortugalBabcock Wanson Caldeiras
Rua dos Transitários - 182 Salas BS e BT4455-565 Perafita (Portugal)Tel: (351) 229 999 490 - Fax: (351)229 999 659 - E-mail: [email protected]
SpainCalderas y Proyectos Babcock Wanson
Carretera Bilbao-Plentzia, 31Edificio Inbisa - Planta 1a - Dp. 107 48950 Erandio (Vizcaya)Tel: (34) 94 4 52 30 36 - Fax: (34) 94 452 30 54 - E-mail: [email protected]
SwitzerlandBabcock Wanson AG
Oberebene Strasse 63 - 5620 Bremgarten (Switzerland)Tel: (41) 56 631 95 80 - Fax : (41) 56 631 95 88- E-mail: [email protected]
Central Europe areaCNIM-Babcock Central Europe
Grafická 848/18 150 00, Praha 5.Tel: +420 (0) 257 286 880 - Fax: +420 (0) 257 310 848 - E-mail: [email protected]
www.babcock-wanson.com
T H E B O I L E R H O U S E S O L U T I O NE Q U I P M E N T
HW Pack:
❚ A complete package : ✓ Boiler with Insulation✓ Burner (Gas or fuel oil)✓ Multifunction Control Panel ✓ Full commissioning and after sales support
❚ 5-year guarantee on the pressure shell❚ Perfectly matched boiler / burner❚ Guaranteed performance
NEW
BS EN ISO 9001:2000FM29856
Hot Water BoilerHW Pack
21 models: from 105 to 4150 kW
Product Description:
❚ 21 models from 105 to 4150 kW net heat output.❚ Innovative and fully proven construction that guarantees high efficiency and long life
due to its low furnace heat loading.❚ Reverse flame design with radial fire tubes for low stress operation.❚ Gas or fuel oil fired with reduced emissions and high combustion efficiency due to the
perfect burner/boiler match.❚ Progressive 2-stage or fully modulating burner control depending on output.❚ Very high efficiency throughout the range. ❚ Maximum operating pressure: 5 bar.❚ Furnace access without removing the
burner.❚ Left or right opening door.❚ Freely expanding main furnace tube.❚ Reinforced thermal insulation and
soundproofing.❚ Epoxy coated sheet steel jacket (RAL
5015).❚ Easy cleaning and maintenance.❚ Combustion turbulators in stainless
steel.
Key Features1 Burner2 Flame viewing port3 Furnace door4 Insulated Jacket5 Water Inlet6 Relief Valve connection7 Instrumentation connection8 Water Outlet9 Fire tubes10 Stainless steel turbulators11 Combustion chamber12 Chimney connection13 Flue gas plenum14 Inspection door15 Condensate drain
Advantages:
❚ Complete package: guaranteedperformance.
❚ Increased reliability.❚ Factory tested.❚ Easy to install.❚ ALL EQUALS = Reduced operating
costs.
Technical Support andService:
❚ Full Commissioning and AfterSales services.
❚ Warranty extensions in conjunctionwith maintenance contracts.
❚ Full parts supply services.
BABCOCK WANSON as one of the leading suppliers ofThermal Solutions and Industrial Boiler Systems for morethan 60 years, remain at the forefront of boiler technologyand are now pleased to offer the HW Pack Hot Water Boiler, a complete boiler package with guaranteed performance.
Ancillaries:
❚ Circulating pumps.
❚ Safety Valve.
❚ Condensate drain Pump.
❚ Skid packages.
❚ Water treatment.
ModelNumber
L L1 P P1 H H1 Ø Dry
weightkg
HW 105 795 753 1100 805 790 410 180 233
HW 150 845 803 1305 1010 840 435 180 263
HW 200 915 875 1430 1105 980 525 200 443
HW 230 915 875 1430 1105 980 525 200 533
HW 290 965 925 1610 1245 1030 550 250 533
HW 315 965 925 1610 1245 1030 550 250 533
HW 410 1140 1100 1890 1450 1210 655 300 835
HW 470 1140 1100 1890 1450 1210 655 300 835
HW 530 1210 1170 2045 1555 1280 690 300 1020
HW 590 1210 1170 2045 1555 1280 690 300 1020
HW 700 1275 1235 2260 1820 1335 715 350 1151
HW 810 1275 1235 2260 1820 1335 715 350 1151
HW 940 1350 1310 2560 2070 1415 755 400 1698
HW 1040 1350 1310 2560 2070 1415 755 400 1698
HW 1180 1460 1400 2760 2220 1510 820 400 1986
HW 1460 1545 1485 2850 2470 1590 865 450 2396
HW 1790 1615 1555 3230 2620 1660 900 500 2971
HW 2360 1610 1610 3535 2970 1950 965 450 3850
HW 2960 1800 1800 3955 3320 2150 1070 500 5200
HW 3550 1800 1800 4255 3620 2150 1070 500 5800
HW 4150 2000 2000 4790 4024 2360 1700 600 8000
MODELNet heatOutput
Efficiency 30%rated power
MAX.Operating
pressure bar
MAX. Outlet
temperature °C
MIN. Inlet
temperature °C
Watercapacity
litres
Inlet/OutletNB
Pressure Drop at
Δ 20°C mbars
HW 105 105 93.4 5 100 55 109 50 15.3HW 150 153 93.2 5 100 55 149 50 17.1HW 200 200 93.6 5 100 55 187 65 19.8HW 230 234 93.1 5 100 55 187 65 40.6HW 290 290 93 5 100 55 216 65 40.6HW 315 316 92.7 5 100 55 216 65 51HW 410 414 93.4 5 100 55 430 80 39.6HW 470 470 92.9 5 100 55 430 80 67.5HW 530 532 93.6 5 100 55 534 100 13.5HW 590 588 93.1 5 100 55 534 100 17.1HW 700 706 93.3 5 100 55 652 100 38.5HW 810 813 92.5 5 100 55 652 100 53HW 940 948 93.5 5 100 55 822 125 45HW 1040 1047 93 5 100 55 822 125 56HW 1180 1188 94.2 5 100 55 1105 125 65HW 1460 1466 93.6 5 100 55 1236 125 46HW 1790 1798 93.1 5 100 55 1432 150 52HW 2360 2360 92.2 6 100 50 2163 150 37HW 2960 2960 92 6 100 50 3155 200 35HW 3550 3550 92.2 6 100 50 3292 200 50HW 4150 4150 92.3 6 100 50 4839 200 70
HW 105 to 150
Dimensions
Technical characteristics
HW 200 to 1790
HW 2360 to 4150
Non contractual values