Safety Lifeline Tester Operating Instruction
Transcript
Page 1: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

SafetyLifeline Tester

Operating Instruction

Page 2: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

1

1. With the cable tester clamp side up, remove the 6 cap headscrews and the top plate clamp using the 6mm A llen key.(Figures 1 and 2).

Figure 1

Figure 2

2. Slide the cable through the slots, replace the top clamp plateand the 6 cap head screws and tighten up using the 6mm Allenkey. Note the position of the clamp in Figure 4.

Figure 3

Figure 4

2

Gap here

Clamp againstblock

Page 3: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

43

3. Remove the 150 load spreading bridge with adjustablefeet by unscrewing the 2 M4 cap screws on the underside ofthe unit. (Figure 5).

Figure 5

5. Remove the M12 round locking adaptor from the inside sloton the bottom of the portable tensioner by first unlocking /slackening the allen screw. (Figures 7 and 8).

Figure 7

Figure 8

4. Make sure that the jaw on the tester is fully closed. Check thisby looking at the mm scale on the main body of the tester whichshould be near the zero indicator. (Figure 6).

Figure 6

Page 4: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

65

6. Remove the operating ball handle from the tester byunscrewing anti-clockwise taking care not to remove the bearingand pressure washers. (Figures 9, 10, 11 and 12).

Figure 10

Figure 9

Figure 11

Figure 12

Page 5: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

87

7. Fit the M22/AF hexagon operating nut in place of the handle.(Figures 13 and 14).

Figure 13

Figure 14

8. Attach the 0-25kN gauge to the Model 2000/C tester bypulling back on the body coupler and clicking into place. Turningthe gauge will allow for easy reading (gauge only moveable withcoupler system fitted). (Figures 15 and 16).

Figure 15

Figure 16

Page 6: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

� ����

10. Operate withthe M22 ratchetspanner toprogressivelyincrease the loadon the swage andnote the readingson the gauge.(Figure 19).

Figure 19

9. The Model 2000/C test should be located over the buttonadaptor on the opposite end to the swage under test. (Figures 17and 18).

Figure 17

Figure 18

Turn operating nut by hand to apply enough tension to securetester.

Turn clockwise

Page 7: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

����

11. The following can be used with the appropriate L/H or R/Hnut. (Figure 21).

85160-00 R/H threaded swage85162-00 L/H threaded swage20502-00 Extended L/H swage

Figure 21

12. The following can be used with the supplied collar. (Figures22, 23, 24).

RH/LH nut

Figure 23Figure 22

Figure 24

Page 8: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

����

.31 Swage Joiner: use of the extra cable clamp is required.(Figures 25, 26, 27, 28). Please note the difference of the ends ofthe clamp as it is designed to locate slightly over the end block.

Figure 28

Figure 26

Figure 27

Figure 25

Page 9: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

����

If any signs of slippage are detected the swage joint mustbe rejected and replaced.

For mechanically fixed end and intermediate anchorssecured to structural steelwork the fixing bolts shall besubjected to a torque check to the recommended values.If the tightening torque value is not achieved the fixingbolts shall be replaced.

For systems supplied in kit form by the swagedconnections between the absorber or terminationand cable has been proof tested to 15kN.Therefore, the system can be directly installed on to thestructure without the need for proof testing on siteprovided the maximum predicted end load does notexceed 15 kN. If the predicted end load is greater than 15kN then a proof test to the maximum predicted end loadshall be carried out as described below.

For systems supplied as individual parts the swageconnection will need to be completed on site using therecommended hexagonal dies with a minimum of 3 swagebites. The connection shall be proof tested to themaximum predicted end load before installation of thesystem. After swaging it is recommended that the acrossflats dimension is checked. The maximum across flatsdimension is 11.2 mm. Any swages greater than 11.2 mmmust be rejected.

It is recommended that the Hydrajaws test kit is used toperform all the proof tests described below.

For swage testing, apply the recommended test load andhold for 3 minutes, checking for any slippage of the cablefrom the swage. This will be indicated by the gauge notholding load and separation of the swage slip indicator(85025) away from the end of the swage termination.

14. Test Load

Page 10: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

�� ��

15. Testing procedure of non “slip indicator” cable swages.(Figures 29, 30, 31, 32, 33). Remove the extension bars byunscrewing the 2 6mm cap head screws using the 5mm balldriver.

Place the kurled adaptor into the end of the block and fix withthe 3mm countersunk screw and collar. Do not overtighten the

.etator ot eerf eb dluohs rotpada delrunk eht sa wercs mm3

Figure 29

Figure 30

Figure 31

Collar

3mmscrew

Page 11: Hydrajaws 8mm Cable Tester Operating Manual - SAYFA

2019

Figure 32 Figure 33


Recommended