+ All Categories
Home > Documents > Hydraulic Turbines

Hydraulic Turbines

Date post: 19-Feb-2016
Category:
Upload: dawit-abraham
View: 24 times
Download: 0 times
Share this document with a friend
Description:
Different type of hydraulic turbine design
Popular Tags:
111
5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com 1 CONTENTS ABOUT COMPANY 4 NPO Privod LLC 4 1. TURBOGENERATORS, SYNCHRONOUS, TWO POLE, AIR COOLED 6 1.1. TTK line turbogenerators with capacity 16…225 MW 6 1.2. T (TS) -series turbogenerators with 2.5…63 MW capacities 8 1.3. TK - series turbogenerators with 1.5…63 MW capacities 10 1.4. GTG - series turbogenerators with 2.5…8 MW capacities 11 1.5. Special-version turbogenerators 12 2. HYDRO TURBINES GENERATORS 14 3. SMALL CAPACITY GENERATORS 16 3.1. SG and SGD synchronous generators 16 3.2. SG-600-2 NF3 and SGV 600-2 NF3 synchronous generators 17 3.3. Synchronous diesel generators 18 3.4. GS synchronous generators 19 3.5. SGTK synchronous generators 20 4. GENERATOR EXCITATION CONTROL SYSTEMS 21 4.1. Brushless diode excitation systems (SVBD) 21 4.1.1. Synchronous generators excitation control cabinets ShUVGM 21 4.1.2 Rotor protection cabinets ShZR and resistor blocks BR. 23 4.1.3. Control systems for synchronous generators’ brushless exciters ShUVG 24 4.2. Static generator excitation systems STS(N) 25 5. TURBOGENERATOR LIFE SUPPORT SYSTEMS 26 5.1. Air cleaner and air recirculation unit 26 5.2. Water recirculation devices in air coolers 26 5.3. Oil supply device for turbogenerator bearings 26 6. TWO POLE SYNCHRONOUS MOTORS, HIGH-SPEED 27 6.1. STDM-series motors with 630…2,000 kW capacities 27 6.2. STD - series motors with 2,500...12,500 kW capacities 29 6.3.STD motors, special version 31 6.4. STDP-series motors, explosion proof 33 6.5. SDG2 motor to operate gas pressurizers 35 6.6. RVSD Frequency-regulated, explosion proof synchronous motor with 14,000 kW capacity 36 6.7. TDS motors with 20,000 and 31,500 kW capacities 37 7. SALIENT POLE SYNCHRONOUS MOTORS 38 7.1. SDK2- and DSK-series compressor motors 38 7.2. SDKP2-series compressor explosion proof synchronous motors 40 7.3. SDN general purpose motors 41 7.4. Vertical synchronous motors SVD for driving vertical hydraulic pumps 42 7.4.1. Vertical synchronous motors, series SVD 143, SVD 173, and SVD 215 42 7.4.2. Vertical synchronous motors, series SVD 325, SVD 375 43 7.5. Synchronous motors SDE2-15-34-6 44 7.6. Synchronous motors SDEUM-16-28-6 45
Transcript
Page 1: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

1

CONTENTS

ABOUT COMPANY 4

NPO Privod LLC 4

1. TURBOGENERATORS, SYNCHRONOUS, TWO POLE, AIR COOLED 6

1.1. TTK line turbogenerators with capacity 16…225 MW 6

1.2. T (TS) -series turbogenerators with 2.5…63 MW capacities 8

1.3. TK - series turbogenerators with 1.5…63 MW capacities 10

1.4. GTG - series turbogenerators with 2.5…8 MW capacities 11

1.5. Special-version turbogenerators 12

2. HYDRO TURBINES GENERATORS 14

3. SMALL CAPACITY GENERATORS 16

3.1. SG and SGD synchronous generators 16

3.2. SG-600-2 NF3 and SGV 600-2 NF3 synchronous generators 17

3.3. Synchronous diesel generators 18

3.4. GS synchronous generators 19

3.5. SGTK synchronous generators 20

4. GENERATOR ExCITATION CONTROL SYSTEMS 21

4.1. Brushless diode excitation systems (SVBD) 21

4.1.1. Synchronous generators excitation control cabinets ShUVGM 21

4.1.2 Rotor protection cabinets ShZR and resistor blocks BR. 23

4.1.3. Control systems for synchronous generators’ brushless exciters ShUVG 24

4.2. Static generator excitation systems STS(N) 25

5. TURBOGENERATOR LIfE SUPPORT SYSTEMS 26

5.1. Air cleaner and air recirculation unit 26

5.2. Water recirculation devices in air coolers 26

5.3. Oil supply device for turbogenerator bearings 26

6. TWO POLE SYNCHRONOUS MOTORS, HIGH-SPEED 27

6.1. STDM-series motors with 630…2,000 kW capacities 27

6.2. STD - series motors with 2,500...12,500 kW capacities 29

6.3.STD motors, special version 31

6.4. STDP-series motors, explosion proof 33

6.5. SDG2 motor to operate gas pressurizers 35

6.6. RVSD Frequency-regulated, explosion proof synchronous motor with 14,000 kW capacity 36

6.7. TDS motors with 20,000 and 31,500 kW capacities 37

7. SALIENT POLE SYNCHRONOUS MOTORS 38

7.1. SDK2- and DSK-series compressor motors 38

7.2. SDKP2-series compressor explosion proof synchronous motors 40

7.3. SDN general purpose motors 41

7.4. Vertical synchronous motors SVD for driving vertical hydraulic pumps 42

7.4.1. Vertical synchronous motors, series SVD 143, SVD 173, and SVD 215 42

7.4.2. Vertical synchronous motors, series SVD 325, SVD 375 43

7.5. Synchronous motors SDE2-15-34-6 44

7.6. Synchronous motors SDEUM-16-28-6 45

Page 2: Hydraulic Turbines

2

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

8. ExCITATION SYSTEMS fOR SYNCHRONOUS MOTORS 46

8.1. Excitation control cabinet for brushless exciters of synchronous motors (ShUVD) 46

8.2. TRN 1P thyristor voltage regulator 47

8.3. Static thyristor excitation systems for synchronous motors type STSN 48

8.4. VTE 10-315 and VTE 630/150 T series analog thyristor exciters for synchronous motors 49

9. ASYNCHRONOUS ExPLOSION PROOf MOTORS WITH A SHORT CIRCUITED ROTOR 50

9.1. VAO series motors 50

9.2. VАО-2500 and VАО-5000 motors 54

9.3. VASO-series explosion proof vertical motors 55

9.4. VAOV series vertical motors 56

10. ExPLOSION PROOf, THREE PHASE ASYNCHRONOUS MOTORS WITH A

SHORT CIRCUITED ROTOR 57

10.1. DAZO4 - series ventilated motors 57

10.2. DAO - type ventilated motors 59

10.3. AOD - type ventilated two - speed motors 60

10.4. AZO - series closed - ventilation motors 61

10.5. DAB special asynchronous motors 62

10.6. DA4 asynchronous motors 62

10.7. DAZ series enclosed two-pole motors 63

10.8. VASV vertical water-cooled special motors 64

10.9. DASO vertical motors 64

10.10. Special asynchronous motors with variable frequency drive 65

10.10.1. Explosion proof asynchronous squirrel-cage motor DARB 1200 6 NF2 65

10.10.2. Asynchronous squirrel-cage DARG 3500 8 UM4 66

10.10.3. Modernized arc-type stator asynchronous motor DADM 750-150 NF1 66

10.11. Vertical asynchronous motors for driving hydraulic pumps 67

10.11.1. AVDN series vertical asynchronous motors 67

10.11.2. AVDN and AVDZ series vertical asynchronous motors for nuclear power plants and thermal power plants 68

10.11.3. DAVD series vertical two-speed asynchronous motors 69

11. MOTORS fOR OPERATION AT NUCLEAR POWER PLANTS 70

11.1. Motors for driving main circulation pumps of nuclear power plants 70

11.1. Vertical closed asynchronous motor DAVZ-8000-6 AM U5 70

11.2. Asynchronous vertical two-speed motor DAVDZ-7100/2800-10000-6/8 AM U5 71

11.3. Motors for driving pumps and high-speed machines 72

11.3.1. Closed asynchronous motors DAZA 72

12. ELECTRICALLY DRIVEN GAS COMPRESSOR UNITS (EGPU) 73

12.1. EGPU on the basis of electric drives fabricated under license of TMEIC; basic configuration of flow diagram 73

12.2. EGPU on the basis of electric drives from MAN Diesel&Turbo, flow diagram – single unit (MOPICO and HOFIM) 75

12.3. Packaged modular EGPU’s 79

12.4. Electrically driven 12.5 MW gas compressor units EGPU (non-controlled) 80

12.5. Electrically driven 12.5 MW gas compressor units EGPU (controlled) 82

12.6. Set of equipment for reconstructing electrically driven gas compressor unit of 12.5 MW 83

12.7. High-speed variable-frequency electric drives EPRV 84

Page 3: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

3

13. TRANSfORMING EQUIPMENT 85

13.1. High voltage frequency converters HV-VFD 85

13.2. High voltage soft starters SSM-HV 86

14. TRACTION ELECTRICAL EQUIPMENT 87

14.1. Traction generators for main-line freight gas turbine locomotives 87

14.1.1. Traction machine ATG-7370/600-6000 N2 87

14.1.2. Synchronous traction generators for main-line freight gas turbine locomotive GT1h 88

14.2. GST traction alternators 89

14.3. GPT 840-750N2 direct current generator 90

14.3. ASTM 2800/600-1000 N2 synchronous traction unit 91

14.4. ASTG 2800/400-1000 N2 and ASTG2 2800/400-1000 N2 synchronous traction units 92

14.5. VST exciters 93

14.6. EDU-133 traction motors 94

14.7. EDU-136 traction motors 95

14.8. DAT asynchronous traction motors 96

14.9. 4PNJ-200MA direct current motors 97

14.10. DTK-800M N1 Direct-current traction motor 98

14.11. DTK-810M NF1 direct-current traction motor 99

14.12. DPT direct current motors 100

14.13. 5SG, 6SG, 7SG starter-generators 101

14.14. DAVT-280-15-4/6/12 N2 (N5) asynchronous traction motor 102

14.15. DATE-170 N2 and DAT-170 N2 asynchronous traction motors 103

14.16. AMVR-37 asynchronous motor for motor-fan 104

14.17. Kicking coils 105

14.17.1. DSF-1L N2 power line filter kicking coil for subway cars 105

14.17.2. DS-2 smoothing kicking coil 105

14.18. Set of electric equipment and automation for locomotives 106

14.18.1. PK-1000L - series electropneumatic contactors 106

14.18.2. PPK-8000L-series electropneumatic switches 107

14.19. DPT-196M N2 traction motor 108

14.20. Privod-TRL1 set of traction electric equipment for trolleybuses with reostatic-contactor control systems 108

14.21. DPT-110 N2 traction motor for trolleybus 109

15. GOST CONVENTIONS 110

15.1. Embodiment (in compliance with GOST 2479) 110

15.2. Cooling method (in compliance with GOST 20459) 110

15.3. Protection level (in compliance with GOST 14254) 110

15.4. Climatic versions (in compliance with GOST 15150) 111

15.5. Categories of location (in compliance with GOST 15150) 111

15.6. Rated operation mode (in compliance with GOST К 52776) 111

15.7. Explosion protection types and levels (in compliance with GOST R MEK 60079-0) 111

Page 4: Hydraulic Turbines

4

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

NPO Privod LLC

occupies leading positions in design, manufacturing and supplies of electrical generating equipment of low and medium power, traction equipment for railway transport.The list of the products supplied by NPO Privod LLC includes over 1,500 positions of electric machines and controlling equipment - gas turbine generators, hydro turbines generators, synchronous and asynchronous motors, electric traction equipment, etc.

ProductsTurbogenerators

Power Output range – 1.5 - 225 MW � for electrical energy generation based on the steam and gas turbines applications. The Turbogenerators have enhanced efficiency and advanced technical design.

Hydro turbines generators

Power Output range – up to 300 MW � for electrical energy generation based on the hydraulic turbines applications.

Hydrо turbines of wide power output range, with both vertical and horizontal design and are manufactured according to GOST and customer’s specific technical requirements.

Synchronous motors

Capacity range 0.315 – 31.5 MW � for pump drives, compressor drives, gas blowers, air blowers and other high-speed equipment applications; � specialized compressor motors with a range of 0.315 - 1 MW.

Asynchronous motors

Capacity range – 6.5 kW – 12.5 MW, rotation speed - 115 - 8,600 rpm � for pump drives, ventilators, smoke exhausters, air blowers, air cooling machines, and other applications; � for nuclear plants.

Horizontal and vertical motors are produced for various climate conditions, with explosion protection.

Electrical gas-pumping units (EGPU) and sets of materiel equipment for EGPU revamp

Capacity range – 4.0 – 8.2 MW rotation speed – 8,000 – 8,600 rpm. � for natural gas compression and transportation through main gas pipelines.

High-speed, gearless, and frequency-regulated gas-pumping units with the rotors on magnetic bearings.

The electric energy consumed by our gas-pumping units is lower by about 30% compare to the equipment provided by other manufacturers. The customer’s capital costs and installation costs are also reduced. The gas pumps can operate in a wide range of ambient conditions – from -60 to +45 °C.

Traction electrical equipment

� for main-line (cargo and passenger) diesel locomotives; � traction motors for subway cars.

New products

The unique experience in the new equipment designing enables NPO Privod LLC to develop high-tech products. The team of designers has a wealth of experience in the designing of new machines, including the development of new projects, customization, diagnostics, and consultancy on operation and maintenance of the output products.

Page 5: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

5

Certification of management system and products

The integrated management system, based on the principles established by three international standards, is introduced on the production site (Electrotyazhmash- Privod LLC): - Quality management system as per ISO 9001:2008; - Environmental management system as per ISO 14001:2004; - Occupational health and safety management system as per OHSAS 18001:2007. As for the production of electrical equipment for the railroad stock, the quality management system has a certificate of conformity to the requirements of GOST R ISO 9001:2008. The products of the Company, for which the Russian legislation provides for obligatory certification, have certificates of conformity. We are licensed to produce equipment for the nuclear power industry and have a certificate of conformity to the operation conditions at Gazprom JSC facilities. NPO Privod LLC cooperates with independent expert organizations: Bureau Veritas General Conditions and FSUE VO Safety. All our equipment can be certified upon customer’s request.

Products Deliveries

The products are in strong demand both in Russia, and abroad. The equipment supplied by NPO Privod LLC is used at power facilities in Africa, Asia, Middle East, and Latin American countries. Total capacity of the equipment, that works in 35 countries worldwide exceeds 50,000 MW.The permanent customers of the Company include leaders of the oil, gas and power industries, transport machinery companies, metallurgical engineering companies and other large facilities.

5, Moldavskaya Str., Moscow, 121467, Russia+7 (495) [email protected]

Page 6: Hydraulic Turbines

6

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

1. TURBOGENERATORS, SYNCHRONOUS, TWO POLE, AIR COOLED

1.1. TTK line turbogenerators with capacity 16…225 MW

TTK tubular body turbogenerators provide electric energy output in connection with steam (P) or gas (G) turbines.

Cooling system closed cycle air cooling with two sectioned air coolers or open cycle cooling system

Cooling method closed cycle ventilation – ICW37A81

open cycle ventilation – IC31

Excitation system static or brushless system

Protection level closed cycle ventilation – IP54

open cycle ventilation – IP21 or IP54

Temperature classification: isolation / application

class F/class В

Rated operating conditions S1

Supplied in compliance with GOST 533 and individual customer's requirements.

TTK Turbogenerators construction is patented.

Delivery set includes: turbogenerator, excitation system, thermal control sensors, mounting equipment, start-up frequency converters (for gas turbines), foundation fastenings, spare parts, and operation documents.

Generator typeCapacity

Voltage, VPhase

connection pattern

Rotation speed, rpm

Efficiency, %

Weight, kg

EmbodimentkW kVA

ТТК-16-2 N3-P 16000 20000 10500 star 3000 98.2 37200 IM 1301

ТТК-16-2 N3-G 16000 20000 10500 star 3000 98.2 37800 IM 1101

ТТК-20,4-C-2R N3-G * 20400 25500 10500 star 3000 98.2 32300 IM 1101

ТТК-25-2 N3-P 25000 31250 6300 delta 3000 98.2 56000 IM 1301

ТТК-25-2 N3-P 25000 31250 10500 star 3000 98.2 56000 IM 1301

ТТК-25-2 N3-G 25000 31250 6300 delta 3000 98.2 55500 IM 1101

ТТК-25-2 N3-G 25000 31250 10500 star 3000 98.2 55500 IM 1101

ТТК-32-C-2 N3-P 32000 40000 10500 star 3000 98.3 53300 IM 1301

ТТК-32-C-2 N3-P 32000 40000 6300 delta 3000 98.3 53300 IM 1301

ТТК-32-C-2 N3-G 32000 40000 10500 star 3000 98.3 53500 IM 1101

ТТК-32-C-2 N3-G 32000 40000 6300 delta 3000 98.3 53500 IM 1101

ТТК-37-C-2R * 37000 46250 10500 star 3000 98.0 54800 IM 1005

ТТК-37-C-2R * 37000 46250 11000 star 3000 98.0 54800 IM 1005

ТТК-37-C-2R * 37000 43530 13800 star 3600 98.0 54800 IM 1005

ТТК-40-2 N3-P 40000 50000 6300 delta 3000 98.4 69500 IM 1301

ТТК-40-2 N3-P 40000 50000 6300 star 3000 98.4 69500 IM 1301

ТТК-40-2 N3-P 40000 50000 10500 star 3000 98.4 69500 IM 1301

ТТК-40-2 N3-G 40000 50000 6300 delta 3000 98.4 70300 IM 1101

ТТК-40-2 N3-G 40000 50000 6300 star 3000 98.4 70300 IM 1101

ТТК-40-2 N3-G 40000 50000 10500 star 3000 98.4 70300 IM 1101

ТТК-50-C-2 N3-P 50000 62500 10500 star 3000 98.4 80300 IM 1101

ТТК-50-C-2 N3-G 50000 62500 10500 star 3000 98.4 81000 IM 1101

ТТК-63-2 N3-P 63000 78750 6300 delta 3000 98.4 104000 IM 7101

ТТК-63-2 N3-P 63000 78750 10500 star 3000 98.4 104000 IM 7101

ТТК-63-2 N3-G 63000 78750 10500 star 3000 98.4 104800 IM 7306

ТТК-80-2 N3-P 80000 100000 10500 star 3000 98.4 116000 IM 7101

ТТК-80-2 N3-G 80000 100000 10500 star 3000 98.4 116000 IM 7306

ТТК-90-2 N3-P 90000 112500 10500 star 3000 98.4 139600 IM7101

ТТК-90-2 N3-G 90000 112500 10500 star 3000 98.4 140000 IM 7306

ТТК-110-2 N3-P 110000 137500 10500 star 3000 98.45 158500 IM 7101

Page 7: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

7

Generator typeCapacity

Voltage, VPhase

connection pattern

Rotation speed, rpm

Efficiency, %

Weight, kg

EmbodimentkW kVA

ТТК-110-2 N3-G 110000 137500 10500 star 3000 98.45 160500 IM 7306

ТТК-125-2 N3-P 125000 156250 10500 star 3000 98.43 159700 IM 7101

ТТК-125-2 N3-G 125000 156250 10500 star 3000 98.43 159700 IM 7306

ТТК-160-2 N3-P 160000 188000 15750 star 3000 98.5 207500 IM 7101

ТТК-160-2 N3-G 160000 188000 15750 star 3000 98.5 210000 IM 7306

ТТК-225-2 N3-P** 225000 264700 15750 star 3000 98,65 278000 IM 1301

ТТК-225-2 N3-G** 225000 264700 15750 star 3000 98,65 280000 IM 1101

Note: * rated power at incoming cooling air temperature +15 °C, weight of generator is shown without AFCS

** Turbogenerator fits in foundation aperture of TVV-220-2ЕN3 generator.

Embodiment:

IM 1005 - feet-based machines with two bearing shields and a single cylindrical shaft end

IM 1101 - high feet-based machines with two bearing shields and a single cylindrical shaft end

IM 1301 - high feet-based machines with one bearing shield and a single cylindrical shaft end

IM 7101 - high feet-based machines with pedestal bearings, without fundament or base plates and with a single cylindrical shaft end

IM 7306 - high feet-based machines with pedestal bearings, without fundament or base plates and with two flanged shaft ends

ТТК - XX С 2 O N (NF) 3 (4) G (P)

G -connected to gas turbineP - connected to steam turbine

category of location

climatic version

open-loop ventilation

number of poles

compact line

rated capacity, MW

tubular body turbogenerator

Page 8: Hydraulic Turbines

8

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

1.2. T (TS)-series turbogenerators with 2.5…63 MW capacities

T-series Turbogenerators coupled with steam (P) or gas (G) turbine are designed for power generation.

Cooling system closed-loop air cooling with water air coolers or open-lop air cooling

Cooling method IC31 - ТС 10 2R NF3

ICW37A71 or IC31 – Turbogenerators with the capacity of 12, 16, 20 and 25 MW

ICW37A71 – other units

Excitation system static or brushless

Location of HV leads of turbogenerators

T-2, 5-2, T-4-2, T-6-2, T-8-2, T-12-2, TS-32-2, T-50-2, TS-63-2 - lower

TS-10-2R or TS-12-2R - side

T-16-2 – lower or side

TS-20-2 and T-25-2 – upper, lower, or side

T-32-2 – upper or lower

Protection level IP44 – Turbogenerators T-2, 5-2, T-4-2, T-6-2 and T-12-2

IP55 - Turbogenerators T-25-2Z N3-G, T-25-2Z N3-P

IP54 - Turbogenerators Т-25-2R N3-G, T-25-2 with the capacity of 16, 20, 32, 50 MW, TS-63-2

Rated operating conditions S1

Manufactured in compliance with GOST 533 and customer’s specific technical requirements.

Design of turbogenerator T-25-2 is protected with utility patent No. 37439; design of turbogenerator TS-63-2 is protected with utility patent No. 36585

Certificates of conformity: No. ROSS RU.MH07.N00338 for T-25-2 N3;No. ROSS RU.MH08.N00077 for Т-16-2R NF3.1;No. ROSS RU.MH08.N00059 for Т-12-2R NF3.

Delivery set includes: turbogenerator, excitation system, thermal control sensors, mounting equipment, foundation fastenings, spare parts, and operation documents.

Generator typeCapacity

Voltage, VPhase

connection pattern

Rotation speed, rpm

Efficiency, %

Weight, kg

EmbodimentkW kVA

Т-2,5-2 N3 P 2500 3125 3150 star 3000 97.0 12500 IM 7011

Т-2,5-2 N3 P 2500 3125 6300 star 3000 97.0 12500 IM 7011

Т-2,5-2 N3 P 2500 3125 10500 star 3000 96.8 12500 IM 7011

Т-4-2 N3 P 4000 5000 3150 star 3000 97.3 15000 IM 7011

Т-4-2 N3 P 4000 5000 6300 star 3000 97.3 15000 IM 7011

Т-4-2 N3 P 4000 5000 10500 star 3000 97.0 15000 IM 7011

Т-6-2 N3 P 6000 7500 3150 star 3000 97.6 22500 IM 7011

Т-6-2 N3 P 6000 7500 6300 star 3000 97.6 20000 IM 7011

Т-6-2 N3 P 6000 7500 10500 star 3000 97.6 20000 IM 7011

Т-8-2 N3 P 8000 10000 6300 star 3000 97.6 27000 IM 7011

Т-12-2 N3 P 12000 15000 6300 star 3000 97.65 28025 IM 7011

Т-12-2 N3 P 12000 15000 10500 star 3000 97.65 28825 IM 7011

ТS-12-2R NF3 (G) 12000 15000 6300 star 3000 97.65 39815 IM 7211

ТS-12-2R NF3 (G) 12000 15000 10500 star 3000 97.65 39815 IM 7211

Т-16-2R NF3.1 (G) 16000 20000 6300 star 3000 97.8 61580 IM 7211

Т-16-2R NF3.1 (G) 16000 20000 10500 star 3000 97.8 61580 IM 7211

Т-16-2 N3-G 16000 20000 6300 star 3000 98.0 61800 IM 7211

Т-16-2 N3-G 16000 20000 10500 star 3000 98.0 61800 IM 7211

Т-16-2 N3-P 16000 20000 6300 star 3000 97.8 52000 IM 7121

Т-16-2 N3-P 16000 20000 10500 star 3000 97.8 52000 IM 7121

Page 9: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

9

Generator typeCapacity

Voltage, VPhase

connection pattern

Rotation speed, rpm

Efficiency, %

Weight, kg

EmbodimentkW kVA

ТS-20-2 N3-G 20000 25000 6300 delta 3000 98.0 66600 IM 7211

ТS-20-2 N3-G 20000 25000 10500 star 3000 98.0 66600 IM 7211

ТS-20-2 N3-P 20000 25000 6300 delta 3000 98.0 56500 IM 7121

ТS-20-2 N3-P 20000 25000 10500 star 3000 98.0 56500 IM 7121

Т-25-2Z N3-G 25000 31250 6300 delta 3000 98.0 85550 IM 7211

Т-25-2Z N3-G 25000 31250 10500 star 3000 98.0 85550 IM 7211

Т-25-2Z N3-P 25000 31250 6300 delta 3000 98.0 75500 IM 7121

Т-25-2Z N3-P 25000 31250 6300 star 3000 98.0 75500 IM 7121

Т-25-2Z N3-P 25000 31250 10500 star 3000 98.0 75500 IM 7121

Т-25-2R N3-G 25000 31250 6300 delta 3000 98.0 85600 IM 7211

Т-25-2R N3-G 25000 31250 6300 star 3000 98.0 85500 IM 7211

Т-25-2R N3-G 25000 31250 10500 star 3000 98.0 85600 IM 7211

ТS-32-2 NF3-P 32000 40000 6300 delta 3000 98.2 78800 IM 7121

ТS-32-2 NF3-P 32000 40000 10500 star 3000 98.2 78800 IM 7121

Т-32-2 V3-P 32000 40000 6300 delta 3000 98.4 77300 IM 7121

Т-32-2 V3-P 32000 40000 10500 star 3000 98.4 77300 IM 7121

Т-32-2 V3-G 32000 40000 6300 delta 3000 98.4 80200 IM 7321

Т-32-2 V3-G 32000 40000 10500 star 3000 98.4 80200 IM 7321

Т-35-2 N3-P 35000 41176.5 6300 delta 3000 98.4 77300 IM 7121

Т-50-2 N3-P 50000 62500 6300 delta 3000 98.2 143000 IM 7121

Т-50-2 N3-P 50000 62500 10500 star 3000 98.2 143000 IM 7121

ТS-63-2 V3-P 63000 78750 6300 delta 3000 98.4 143000 IM 7121

ТS-63-2 V3-P 63000 78750 10500 star 3000 98.4 143000 IM 7121

Т (ТS) - XX - 2 R (Z) - N (V, T, NF) 3 (3.1) G (P)

G - connected to gas turbine P - connected to steam turbine

category of location

climatic version

R-open-loop ventilation Z-closed-loop ventilation

number of poles

capacity, MW

Т – turbogenerator ТS – turbogenerator, special version

Page 10: Hydraulic Turbines

10

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

1.3. TK-series turbogenerators with 1.5…63 MW capacities

Turbogenerators with open-loop ventilation coupled with gas (G) turbines are designed for power generation as a part of steam turbine power plants.

Turbogenerators TK with closed-loop ventilation coupled with steam (P) turbines are designed for power generation as apart of steam turbine power plants.

Embodiment IM 1001

Cooling system turbogenerators with open-loop ventilation – air cooling (can be equipped with air treatment and recirculation unit)

turbogenerators with closed-loop ventilation – through water air cooler, located at the top of the casing

Cooling method IC31 - Turbogenerators with open-loop ventilation

ICW37A81 - Turbogenerators with closed-loop ventilation

Excitation system brushless

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST 533 and customer’s specific technical requirements.

Design of Turbogenerators with open-loop ventilation is protected with utility patent No. 29188.

Certificates of conformity:No. ROSS RU. MH08. N 00064 for TK-6-2R N3;No. ROSS RU. MH08. N 00060 for TK-2.5-2R NF3.

Delivery set includes: turbogenerator, excitation system, thermal control sensors, mounting equipment, foundation fastenings, spare parts, and operation documents.

Generator typeCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

ТК-1,5-2R NF3 1500 1875 6300 3000 95.8 7600

ТК-1,5-2R NF3 1500 1875 10500 3000 96.0 7600

ТК-1,5-2Z NF3 1500 1875 6300 3000 96.0 7600

ТК-1,5-2Z NF3 1500 1875 10500 3000 96.0 7600

ТК-2,5-2R NF3 2500 3125 6300 3000 96.8 12700

ТК-2,5-2R NF3 2500 3125 10500 3000 96.7 12700

ТК-2,5-2Z N3 2500 3125 6300 3000 96.8 10500

ТК-2,5-2Z N3 2500 3125 10500 3000 96.7 10500

ТК-4-2R NF3 4000 5000 6300 3000 97.0 13000

ТК-4-2R NF3 4000 5000 10500 3000 97.0 13000

ТК-4-2Z N3 4000 5000 6300 3000 97.2 13500

ТК-4-2Z N3 4000 5000 10500 3000 97.0 13500

ТК-6-2R NF3 6000 7500 6300 3000 97.4 20040

ТК-6-2R NF3 6000 7500 10500 3000 97.4 20040

ТК-6-2Z N3 6000 7500 6300 3000 97.4 18000

ТК-6-2Z N3 6000 7500 10500 3000 97.4 18000

Т К - X - 2 R (Z) NF (N) 3

category of location

climatic version

R-open-loop ventilation, Z-closed-loop ventilation

number of poles

capacity, MW

mounted in a housing

turbogenerator

Page 11: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

11

1.4. GTG-series turbogenerators with 2.5…8 MW capacities

GTG Turbogenerators coupled with gas (G) turbines are designed to operate as part of gas turbine power stations.

Embodiment IM 7211

Cooling system open-loop

Cooling method IC31

Excitation system brushless

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST 533 and customer’s specific technical requirements.

Design of Turbogenerators is protected with utility patent No. 29188.

Certificates of conformity:

No. ROSS PU. MH02. N 00058 for GTG-2, 5-2R NF3 and GTG-4-2R NF3;

No. ROSS PU. MH08. N 00068 for GTG-6-2R NF3.

Delivery set includes: turbogenerator, excitation system, thermal control sensors, mounting equipment, foundation fastenings, spare parts, and operation documents. Can be equipped with air treatment and recirculation unit.

Generator typeCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

GTG-2,5-2R NF3 2500 3125 6300 3000 96.8 13900

GTG-2,5-2R NF3 2500 3125 10500 3000 96.7 13900

GTG-4-2R NF3 4000 5000 6300 3000 97.2 15550

GTG-4-2R NF3 4000 5000 10500 3000 97.0 15550

GTG-6-2R NF3 6000 7500 6300 3000 97.5 20500

GTG-6-2R NF3 6000 7500 10500 3000 97.5 20500

GTG-8-2R NF3* 8000 10000 6300 3000 97.6 27360

GTG-8-2R NF3* 8000 10000 10500 3000 97.5 27360

* GTG-8-2R NF3 generator may be delivered with closed-loop ventilation

GTG - XX - 2 - R NF 3

category of location

climatic version

open-loop ventilation

number of poles

capacity, MW

gas turbogenerator

Page 12: Hydraulic Turbines

12

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

1.5. Special-version turbogenerators

T-2.5-3600 T3 and T-4-3600 T3 are three phase turbogenerators with frequency of 60 Hz and Rotation speed of 3,600 rpm, equipped with electric excitation unit; they are designed to operate with steam turbine in non-explosive environment in the tropics.

TK-2.5 2Z T3 three phase turbogenerator, frequency - 50 Hz, voltage - 6,600 V, Rotation speed - 3,000 rpm, brushless excitation system, is designed for electric power generation in operation with a steam turbine in explosion-proof atmosphere in the tropics.

TM-4-3600 T3 three phase turbogenerator with frequency of 60 Hz, Rotation speed of 3,600 rpm and brushless exciter is designed to operate with steam turbine in non-explosive environment in the tropics.

T-6-2R T3.1 two plug-in friction bearing turbogenerator with brushless exciter, open loop type ventilation and side outputs location is installed in transportable automatic power stations with marine gas turbine motor drive in the tropics.

T-6-2Z N3.1 two plug-in friction bearing turbogenerator with brushless exciter, close loop type ventilation and side outputs location is designed to operate with gas-turbine motor drive under temperate conditions.

T-6-2Z T3.1 two plug-in type friction bearing turbogenerator with brushless exciter, close loop type ventilation and side outputs location is designed to operate with gas-turbine motor drive in the tropics.

T-6-2R N3 turbogenerator with top location of the stator lead is designed to operate with gas turbine motor.

T-12-2E N3 turbogenerator with top location of the stator lead is designed to be installed in packaged or floating gas-turbine power stations.

TP-12-2 N3 (T3) EP turbogenerator with the following explosion protection type “Case filling or blowing under P excess pressure valve IExpxIIT5X in compliance with GOST R 51330.0.” is designed for continuous running with a top pressure recovery turbine (TPRT).

T-12-2.2 N3 two pillar type friction bearing turbogenerator with bottom location of the stator lead is designed to operate with steam turbines drive.

TT-12-2A N3 turbogenerator with bottom location of the stator lead and open loop type ventilation is designed to operate with GTER-12 gas turbine drive.

T-4.5-2I T3, T-5-2I T3, T-6-2I Т3, T-7.5 -2I Т3, T-7, 7-2I T3, and T-12-2 T3 turbogenerators with one pillar type bearing are designed for electric power generation in operation with a steam turbine (50 Hz AC) in the tropics.

T-25-3600 T3 turbogenerator with bottom location of the stator lead and closed-loop type ventilation, on two pillar type friction bearings, without base plate is designed for electric power generation in operation with a steam turbine (60 Hz AC) in the tropics.

Delivery set includes: turbogenerator, excitation system, thermal control sensors, mounting equipment, foundation accessories, spare parts, and operation documents.

Generator typeCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

Т-2.5-3600 Т3 2500 3125 6300 3600 96.5 12500

ТК-2.5-2Z Т3 2500 3125 6600 3000 96.8 10500

Т-4-3600 Т3 4000 5000 6300 3600 96.6 15000

ТМ-4-3600 Т3 4000 5000 6300 3600 96.6 15000

Т-4.5-2I Т3 4500 5625 11000 3000 97.2 20000

Т-5-2I Т3 5000 6250 11000 3000 97.4 21120

Т-6-2R Т3.1 6000 7500 6300 3000 97.3 16000

Т-6-2R Т3.1 6000 7500 10500 3000 97.3 16000

Т-6-2Z N3.1 6000 7500 6300 3000 97.3 16800

Т-6-2Z N3.1 6000 7500 10500 3000 97.3 16800

Т-6-2Z Т3.1 6000 7500 6300 3000 97.3 16800

Т-6-2Z Т3.1 6000 7500 10500 3000 97.3 16800

Т-6-2I Т3 6000 7500 6600 3000 97.6 23500

Т-6-2I Т3 6000 7500 11000 3000 97.6 24000

Page 13: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

13

Generator typeCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

Т-6-2E N3 6000 7500 6300 3000 97.48 22850

Т-7.5-2I Т3 7500 9375 11000 3000 97.7 26100

Т-7.7-2I Т3 7700 9625 11000 3000 97.6 26100

Т-12-2 Т3 12000 15000 6600 3000 98.0 29000

Т-12-2 Т3 12000 15000 11000 3000 98.0 30450

Т-12-2E N3 12000 15000 6300 3000 97.65 29800

Т-12-2E N3 12000 15000 10500 3000 97.65 30400

ТP 12-2 N3 (Т3) 12000 15000 6300 3000 97.65 28600

ТP 12-2 N3 (Т3) 12000 15000 10500 3000 97.65 29400

ТP 12-2 N3 (Т3) 12000 15000 11000 3000 97.65 29800

Т-12-2.2 N3 12000 15000 6300 3000 97.65 29880

Т-12-2.2 N3 12000 15000 10500 3000 97.65 30680

Т-12-2А N3 12000 15000 10500 3000 97.65 31800

Т-25-3600 Т3 25000 31250 10500 3600 97.7 59900

Т (ТP, ТК) - X - 2 - R (Z) I (E, А) N(Т) 3 (3.1)

category of location

climatic version

E - for packaged and floating power stations,A - for delivery to Argentina,I - for delivery to India

R - open ventilation loopZ - close ventilation loop

number of poles

capacity, MW

T-turbogeneratorTP-ventilated turbogeneratorTK- casing-type turbogenerator

Т (ТМ) - XX - 3600 Т 3

category of location

climatic version

rotation speed, rpm

capacity, MW

T-turbogeneratorTM – marine turbogenerator

Page 14: Hydraulic Turbines

14

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

2. HYDRO TURBINES GENERATORSThe production facilities of NPO Privod LLC allow the manufacture of air-cooled hydro turbines generators with a wide range of capacities, from 1 to 300 MW, vertical or horizontal types of constructions, thus ensuring that almost any customer’s requirements are met. The team of the Company’s specialists and designers of the engineering center of Electrotyazhmash-Hydroengineering LLC have a wealth of experience in designing of the new hydro turbines generators and retrofitting of the obsolete ones at the operated hydropower stations both in Russia and abroad.

The hydro turbines generators are delivered complete with auxiliary systems (excitation, cooling, braking, fire-extinguishing, thermal control and others), sets of spare parts, tools and accessories for installation and for guaranteed and designed commercial operation.

Fabrication is in line with GOST 5616-89 and specific technical requirements of the customer.

List of hydro turbines generators in production, with facilities at which they operate:

Type of hydro turbine

generatorCapacity, kW

Rotation speed, rpm

Voltage, V Embodiment Qnty Operating companyYear of supply

Country

VGS 260/20-24 680 250 6300 vertical 1 Kuzu Gusarksaya HPS 1955 Uzbekistan

VGS 260/20-24 680 250 6300 vertical 2 Skorodninskaya HPS 1957 Russia

VGS 260/34-24 1250 250 6300 vertical 1 Mozhayskaya HPS 1958 Russia

VGS 260/34-24 1250 250 6300 vertical 1 Sheshnevskaya HPS 1959 Russia

SGG 1600-600 1600 600 6300 horizontal 2 Gergebilskaya HPS 1959 Russia

GS 213/15-24 200 250 400/230 1 HPS Krasnoy Armii 1960 Turkmenistan

VGSP 213/24-28 400 214.3 6300 vertical 2 Kudrinskaya HPS 1960 Kazakhstan

VGSP 215/24-16 800 375 6300 vertical 2 Antonovskaya HPS 1960 Kazakhstan

VGSP 213/15-20 320 300 400/230 vertical 1 HPS Aksu 1961 Kazakhstan

VGSP 215/20-20 500 300 6300 vertical 2 HPS Murgab 1961 Tajikistan

VGSP 213/29-14 1000 428.6 6300 vertical 2 Uslenovskaya HPS 1961 Russia

SGG 2500-750 2500 7500 6300 horizontal 3 Zeykhurskaya HPS 1961-1963 Azerbaijan

VGSP 325/69-28 4000 214.3 6300 vertical 1 HPS Ladyzhinskaya 1962 Russia

VGSP 213/24-28 400 214.3 400/230 vertical 1 Okulovskaya HPS 1963 Russia

VGS 260/24-24 840 250 6300 vertical 1 HPS of the Shershinskoye water reservoir

1963 Russia

VGS 260/34-24 1250 250 6300 vertical 1 Belokholunitskaya HPS 1963 Russia

VGS 375/79-24 8800 250 6300 vertical 1 Tsentralnaya HPS 1963 Russia

VGSP 213/29-14 1000 428,6 6300 vertical 2 Sergeyevskaya HPS 1964 Kazakhstan

VGS 260/34-24 1250 250 6300 vertical 4 Ruzskaya HPS 1964 Russia

VGS 4500-375 4500 375 6300 vertical 1 Sosenskaya HPS 1964 Russia

VGS 525/150-20 46000 300 10500 vertical 1 Kubanskaya HPS-2 1964 Russia

VGS 213/24-14 800 428.6 6300 vertical 3 HPS Vanch 1966 Georgia

VGSP 215/20-20 500 300 6300 vertical 1 HPS Shudisand 1967 Kirghizia

VGSP 215/20-20 500 300 6300 vertical 2 HPS Shudsksand 1967 Tajikistan

VGS 275/140-10 14350 600 6300 vertical 2 HPS Chamezgi 1967 Abkhazia

SGG 2000-600 2000 600 6300 horizontal 5 HPS Khorog 1967-1972 Tajikistan

VGS 325/89-14 10000 428.6 6300 vertical 3 Atbashinskaya HPS 1969-1970 Kirghizia

VSG 260/31-18Т 1600 333.3 6300 vertical 2 HPS Mansur 1972 Morocco

VSG 260/31-18 1600 333.3 6300 vertical 1 Vazuzskaya hydrosystem 1972 Russia

VSG 260/31-18 1600 333.3 6300 vertical 2 HPS 34 of Mozhaysky waterworks

1997 Russia

SV-260/65-12 6000 500 6300 vertical 1 Sengileyevskaya HPS 2005 Russia

Page 15: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

15

Type of hydro turbine

generatorCapacity, kW

Rotation speed, rpm

Voltage, V Embodiment Qnty Operating companyYear of supply

Country

SV-465/215-16 56100 375 10500 vertical 1 HPS Argel 2005 Armenia

VGSМ-1525/135-120 66000 50 10500 vertical 3 Saratovskaya HPS 2005-2007 Russia

SV-328/79-32 NF4 3550 187,5 10500 vertical 4 Yegorlykskaya HPS 2 2009 Russia

SV-448/140-18 ТВ4 43470 400 13800 vertical 2 HPS Baytun 2011 Panama

SV-783/105-40 52250 150 13800 vertical 1 HPS Rukatayo 2011 Chile

SV-640/140-30 50000 200 10500 vertical 2 Gotsatlinskaya HPS 2012 Russia

Generators in the process of fabrication

Type of hydro turbines

generatorCapacity, kW

Rotation speed, rpm

Voltage, V Embodiment Qnty Operating companyYear of supply

Country

VGSM 1525/135-120 66000 50 10500 vertical 2 Saratovskaya HP 2013-2014 Russia

SV-360/100-16 16150 450 13800 vertical 3 HPS Sarapuyo 2015 Equador

SV-580/190-24 68000 300 13800 vertical 3 HPS Ayurikin 2015 Equador

SV-845/135-40 73000 150 10500 vertical 7 Ust-Hantaiskaya HPS 2014-2021 Russia

VGS (VGSМ, SV, VSG, GS) - XXX / YY - NF (Т) 4

category of location

climatic version

number of poles

stator core, size, cm

stator core diameter, cm

VGS - synchronous vertical hydro-generatorVGSM – modernized synchronous vertical hydrogeneratorSV - synchronous verticalVSG - synchronous vertical hydro-generator GS – synchronous hydrogenerator

SGG XXXX - YYY NF 4

category of location

climatic version

rotation speed, rpm

capacity, kW

synchronous horizontal hydrogenerator

Page 16: Hydraulic Turbines

16

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

3. SMALL CAPACITY GENERATORS

3.1. SG and SGD synchronous generators

SG 16-31.5-6 Nf3 synchronous generator is designed for power generation with gas turbine, and SGD 16-31.5-2 Nf2 synchronous generator – with diesel motors.

They are installed in transportable power stations.

Embodiment IM 1001

Cooling system air cooling, open-loop

Cooling method IC01

Excitation system brushless

Protection level IP22

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007 and customer’s specific technical requirements.

Delivery set includes: generator, exciter, control station, spare parts, and operation documents.

Type of productCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

SG16-31.5-6 NF2 1000 1250 6300 1000 95.0 5450

SGD16-31.5-6 NF2 1000 1250 6300 1000 95.2 5600

SG (SGD) - 16 - 31.5 - 6 NF 2category of location

climatic version

number of poles

stator core size, cm

size designation

synchronous diesel generator

Page 17: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

17

3.2. SG-600-2 Nf3 and SGV-600-2 Nf3 synchronous generators

The SG-600-2 Nf3 and SGV-600-2 Nf3 synchronous generators are designed to generate power as part of pneumatic electric generator units on the basis of energy derived from gas pressure differences in gas production, transportation and distribution systems

Embodiment IM 1103

Height of rotation axis 300 mm

Cooling system open-loop. Generator is cooled with the natural gas passing through the shell (about 98% methane) in compliance with GOST 51.40-93. Cooling of the excitation control unit – air self-cooling

Excitation system brushless. Generator SGV2 600 2 NF3 allows connection to mains by self-synchronization

Protection level IP10

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007 and customer’s specific technical requirements.

Delivery set includes: generator, excitation system with control unit, spare parts, and operation documents.

Type of generatorCapacity

Voltage, V Rotation speed, rpmEfficiency,

%Power factor Weight, kg

kW kVA

SG-600-2 NF3 600 750 400 3000 89.0 0.8 2040

SGV-600-2 NF3 600 750 10500 3000 90.0 0.8 2050

SGV2-600-2 NF3 600 750 10500 3000 90.0 0.8 2050

SG (SGV) - 2 - 600 - 2 NF 3category of location

climatic version

number of poles

capacity, kW

series

synchronous generator (high-voltage synchronous generator )

Page 18: Hydraulic Turbines

18

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

3.3. Synchronous diesel generators

Synchronous diesel generators are designed to generate power as a part of diesel power plants. Designed for use as a main or standby three phase AC power supply driven by combustion motors.

Embodiment IIM 1305 – GSD generatorsIM 1101 – SGDP generators

Cooling system air cooling, open-loop

Cooling method IC01 - GSD-800-750 NF2 (NF4), GSD-1000-1000 NF4IC31 - GSD-1650-1000 NF2 (N2, T2), GSD-1600-1000 NF4, GSD-1100-1000 NF2 ICW37A71 - SGDP-3150-12 N3

Excitation system brushless

Protection level IP23 - GSD-800-750 NF4IP44 – other generators

Explosion protection type and level

ExpIIT3 - SGDP-3150-12 U3

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007 and customer’s specific technical requirements.

Delivery set includes: exciter, excitation controller, excessive pressure monitor (for SGDP-3150-12N3), component parts, and operation documents.

Type of generatorCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

GSDF-800-750 NF3 (Т3) 800 1000 6300 750 95.0 6600

GSD-800-750 NF2 800 1000 6300 750 95.2 6010

GSD-800-750 NF2 800 1000 10500 750 95.5 6110

GSD-800-750 NF4 800 1000 400 750 95.2 5750

GSD-1000-1000 NF4 1000 1250 400 1000 96.1 5650

GSD-1000-1000 NF4 1000 1250 6300 1000 95.9 5450

GSD-1000-1000 NF4 1000 1250 11000 1000 95.9 5450

GSD-1100-1000 NF2 1100 1375 6300 1000 96.2 6180

GSD-1100-1000 NF2 1100 1375 10500 1000 96.0 6145

GSD-1600-1000 NF4 1600 2000 10500 1000 95.5 9000

GSD-1650-1000 NF2 (N2, Т2) 1650 2062 6300 1000 95.8 9000

GSD-1650-1000 NF2 (N2, Т2) 1650 2062 10500 1000 95.5 9000

SGDP-3150-12 N3 3150 3938 6300 500 96.0 24000

GSD F - XXX - XXX NF (N, Т) 2 (3, 4)

category of location

climatic version

rotation speed

capacity, kW

flanged

synchronous diesel generator

SGDP - 3150 - 12 N 3

category of location

climatic version

number of poles

capacity, kW

synchronous, ventilated diesel generator

Page 19: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

19

3.4. GS synchronous generators

The synchronous diesel generators are designed to generate three phase AC electric power as a part of a bio-energy plant.

Embodiment IM 1001

Cooling system air cooling, open-loop

Cooling method IC01

Excitation system brushless

Protection level IP22

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007 and customer’s specific technical requirements.

Delivery set includes: generator, exciter, control station, half-coupling, key, spare parts, and operation documents.

Type of generatorCapacity

Voltage, V Rotation speed, rpm Efficiency, % Weight, kgkW kVA

GS-600-1500 NF2 600 750 6300 1500 95.75 3700

GS-630-1500 NF2 630 787.5 400 1500 96.04 3700

GS - XXX - 1500 NF 2

category of location

climatic version

rotation speed

capacity, kW

synchronous generator

Page 20: Hydraulic Turbines

20

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

3.5. SGTK synchronous generators

The synchronous diesel generators are designed for application in modern high efficiency power generators based on gas piston engines manufactured by Kawasaki Heavy Industries (Japan).

Cooling system air cooling, open-loop

Cooling method open-loop IC 01 ventilation

Excitation system static or brushless

Protection level IP23

Temperature classification: isolation / application

Class F/ Class B

Rated operating conditions S1

Manufactured in compliance with GOST 52776 and customer’s specific technical requirements.

SGTK synchronous generators construction is patented.

Special characteristics:

� unique embodiment; � low noise level; � low vibration level; � high efficiency index; � high efficiency cooling system; � easy maintenance; � high level technical design.

Type of generatorCapacity

Voltage, VPhase

connection pattern

Rotation speed, rpm

Efficiency, %

Weight, kg

EmbodimentkW кVA

SGTK-5200-750 NF4 5200 6500 10500 star 750 97,3 24500 IM 1101

SGTK-7800-750 NF4 7800 9750 10500 star 750 97,5 29500 IM 1101

* Design according to installation type (GOST 2479): IM 1101 - Machines with feet, two bearing shields and one cylindrical shaft end

SGTK - 5200 (7800) - 750 NF 4

category of location

climatic version

rotation speed

capacity, kW

synchronous generator

Page 21: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

21

4. GENERATOR ExCITATION CONTROL SYSTEMS

4.1. Brushless diode excitation systems (SVBD) The SVBD-type excitation systems are fabricated in compliance with the technical specifications KNPG 651441.004 TU and meet the requirements of GOST 21558-2000. The SVBD-type excitation systems have a certificate of conformity to GOST-R No. 0716430.

Depending on the generator type capacity, the SVBD system consists of the following assembly units: � diode brushless exciter (VBD or 2VBD); � generator excitation control cabinet (ShUBGM); � rotor protection cabinet (ShZR), as required; � dropping resistor, consisting of one or several resistor blocks (BR), as required.

4.1.1. Synchronous generators excitation control cabinets ShUVGMDigital control systems for brushless exciters of synchronous generators ShUVGM are designed for the following functions:

� supplying of the excitation windings of the exciters for synchronous turbine generators with automatically controlled current; � initial excitation of the generator to the set point; � adjustment of the generator voltage to the mains voltage; � line and dedicated load operation in all permissible modes – from idling to rated load; � operation in the auto and manual control modes with bumpless switching between the modes; � bumpless switching between the channels for a two-channel system; � excitation forcing in the case of voltage drop at the generator’s busbars; � limitation of the minimal excitation by the generator performance curve; � limitation of the forcing excitation current value by the set level and duration; � excitation winding overload limitation; � generator field suppression in the case of emergency and normal shutdown; � communication with the higher-level ACS. � control via digital interface from ACS (telecontrol); � provision of protections for excitation system and generator (protection of brushless exciter against abnormal modes and loss of excitation, generator protection against

rotor overheating, overcurrent and overvoltage, high stator voltage and underfrequency protection, reverse power protection etc).

The ShUVGM excitation control systems provide supplying of the excitation windings of the brushless exciters for synchronous turbine generators with the capacity of up to 60 MW and higher with automatically controlled direct current.

Manufactured in compliance with GOST R 21558-2000 and customer’s specific technical requirements.

Excitation system power supply (independent, self excitation) according to Customer’s needs

Delivery set includes: � control cabinet; � set of feeding transformers, type OLS-1.25/6(10) U2 – 3 pcs, or 3-phase transformers 6000(10500)V/380V, 4 (6) kVA - 1(2) pcs. on request; � set of spare parts and accessories; � operation documents.

Page 22: Hydraulic Turbines

22

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

ShUVGM Series Excitation Control Cabinets

Main technical parameters ShUVGM--(S)-250-1(2)-xx-xxx ShUVGM--(S)-PSS-2E-20-100 T

XX-XXX 8-80 10-100 (А) 15-100 (A)

Automatic excitation control with/without power system stabilizer

without PSS c PSS

Rated rectified voltage, V 80 100 100 100

Rated rectified current, A 8 10 15 20

Ceiling current factor, p.u., (relatively to Ife rated), min 2,5 2 2 2,5

Ceiling time, sec, min 20(50) 20(50) 20(50) 20(50)

Rated power supply voltage, V

AC/DC 380 380 380 380

Auxiliary DC 27 or 220 (110) 220 (110) 220 (110) 220 (110)

Service One-sided One-sided, Two-sided

One-sided, Two-sided

One-sided, Two-sided

Protection rating IP21 or other – upon request

Climatic version NF, U, Т

Location category 4

Overall dimensions LxBxH 600х400х1100 800х600х2000 - One-sided, 600х600х2000 - Two-sided

Recommended generator capacity Up to 12 МW Up to 25 МW Up to 60 МW Over 60 МW

Designation of excitation control cabinets ShUVGM-S-250-2Е-15-100 А Nf4 means the following:

ShUVGM - -S- - 250 - 1 (2) Е - 15 - 100 А NF (F, N) 4

location category

climatic version

A – autosynchronizer (option)

rated rectified voltage, V

rated current of cabinet (rectified), A

natural cooling

number of control channels for control and power parts

regulator series

- independent, S – self-excitation

microprocessor-based generator excitation control cabinet

features of ShUVGM-(S)-250 series cabinets:

� Communication interfaces Profibus DP, RS-485 (Modbus RTU protocol), Ethernet (Modbus TCP protocol); � Integrated generator protections (27, 59, 81O, 81U, 32R, 40Q, 25); � Programmable I/O’s of the ARV controller (automatic excitation control); � Advanced service functions (event log, oscillograph, recorder); � Real time clock; � control via digital interface from ACS (telecontrol).

Additional functions of ShUVGM-(S)-250 series cabinets:

A - Autosynchronizer integrated in the ARV controller (option).

Page 23: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

23

Обозначение типа шкафов управления возбуждения ШУВГМ-(С)-PSS-2Е-20-100 УХЛ4 расшифровывается следующим образом:

SHuVGM - S - PSS - 1 (2) Е - 20 - 100 Т NF (U, Т) 4

location category

climatic version

Т – telecontrol (option)

rated rectified voltage, V

rated current of cabinet (rectified), A

natural cooling

number of control channels for control and power parts

регулятор сильного действия

S - self-excitation – independent excitation

microprocessor-based generator excitation control cabinet

features of ShUVGM-(S)- PSS series cabinets:

� the utilized controller passed the comprehensive tests at the TSO RDO branch office (Transmission System Operator Regional Dispatching Office) and is recommended for use at the power plants of the Unified Energy System of Russia for generators of any capacity;

� advanced service functions (event log, oscillograph, recorder); � real time clock;

4.1.2 Rotor protection cabinets ShZR and resistor blocks BR.The cabinets are designed for protection of the rotor winding against commutation and transition overvoltages and against rotor fault to ground.

Delivery set: � Rotor protection cabinet; � Resistor block(s) BR-20; � Set of spare parts and accessories; � Operation documents

Main technical parameters ShZR-500-300

Rated voltage, V 300

Rated current, A 500

Rates supply voltage, V

control AC 220

control DC 220

Servicing One-sided

Protection class IP21 or other – upon request of the customer

Climatic version 4

Location category NF, U, Т

Overall dimensions LxBxH 600х600х2000

Resistor blocks BR are designed for bypassing the rotor winding in case of activation of the excitation system protections.

Main technical parameters БР-20

Power, W 21500

Protection class IP21 or other – upon request of the customer

Location category 4

Climatic version NF, U, Т

Overall dimensions LxBxH 780х750х900

Page 24: Hydraulic Turbines

24

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

4.1.3. Control systems for synchronous generators’ brushless exciters ShUVG

Digital excitation control systems ShUVG are designed for supplying of the excitation windings of the exciters for synchronous turbine generators with automatically controlled current and have the following functions:

� initial excitation; � excitation field suppression; � adjustment of the generator voltage to the mains voltage before connection of the generator to the mains; � equipment monitoring and fault diagnostics; � adjustment and control in the normal and emergency operating conditions of the turbine generator; � communication with the higher-level control and monitoring; � package of protections for the excitation system equipment and generator (brushless exciter against abnormal conditions and loss of excitation; generator rotor against

overloading and overheating; generator against stator overvoltage and underfrequency).

ShUVG-200 Nf4 is designed for excitation control of generators GTG, TK, and T with the capacity of up to 8 MW.

ShUVG-220 Nf4, ShUVG-240 Nf4 are designed for excitation control of generators GTG, TK, T, and TS with the capacity of up to 32 MW.

Manufactured in compliance with GOST 21558-2009 and specific technical requirements of the customer.

features:

ShUVG-200 Nf4: � compact cabinet; � IP44 protection class; � function of the turbine generator’s parameters recording in the normal and emergency conditions with the adjustable discretization of the registered parameters

recording, the nominal value is 0.1 sec; user-friendly function of records archive copying and data viewing using a FLASH memory; � two industrial interfaces RS-485 for communication with ACS of the power plant and backup panel; � function of ShUVG-200 remote control and parameters setting, using the backup operator’s panel; � autosynchronizer functions at the software level, for connection to the mains by the precise synchronization method; the necessity to use a separate cabinet for the

autosynchronizer is eliminated; � generator’s reactive power unloading for normal generator shutdown;

ShUVG-220 Nf4, ShUVG-240 Nf4: � function of remote control and parameters setting, using the backup operator’s panel, via RS-485

Delivery set: � control cabinet; � set of feeding transformers, type OLS-1,25/6(10) U2 (for ShUVG-220 NF4 and ShUVG-240 NF4 – 3 pcs, for ShUVG-200 NF4, ShUVG-200 NF4 – 1 pc) – upon request; � set of spare parts and accessories (including software for ShUVG adjustment using the digital communication channel); � operation documents.

Main technical parameters ShUVG-200 Nf4ShUVG-220 Nf4

ShUVG-240 Nf4

Rated excitation winding voltage, V 60 90

Rated current, A up to 25

Current forcing ratio, power units 2

Forcing duration, sec, not less than 50

Rated supply voltage, V

AC 220 3х380

control DC 27 or 220 110 or 220

Servicing One-sided ShUVG-220 NF4 one-sided;

ShUVG-240 NF4 two-sided

ShUVG - 2 0 (2; 4) 0 NF 4

location category

climatic version

for brushless exciters

0 – in one-sided service cabinet of compact design with one matching transformer2 – in one-sided service cabinet with one matching transformer4 – in two-sided service cabinet with two matching transformers

two-channel system with the AVR automatic excitation controller and excitation current controller

generator excitation control cabinet

Page 25: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

25

4.2. Static generator excitation systems STS(N)

Static generator excitation systems with energization from the generator’s busbars (STS) and with energization from an independent source or after the generator breaker (STSN) are designed for the following functions:

� supplying of the excitation windings of the generators with automatically controlled current in the normal and emergency operating conditions; � initial excitation of the generator to the set point; � adjustment of the generator voltage to the mains voltage; � line and dedicated load operation in all permissible modes – from idling to rated load; � operation in the auto and manual control modes with bumpless switching between the modes; � bumpless switching between the channels for a two-channel system; � excitation forcing in the case of voltage drop at the generator’s busbars; � limitation of the minimal excitation by the generator performance curve; � limitation of the forcing excitation current value by the set level and duration; � excitation winding overload limitation; � generator field suppression in the case of emergency and normal shutdown; � communication with the higher-level ACS � provision of protections for excitation system and generator (against loss of excitation, generator rotor overheating, rotor overcurrent and overvoltage,

generator protection against high stator voltage and underfrequency protection etc.).

Manufactured in compliance with GOST 21558-2000 and specific technical requirements of the customer.

Main technical parameters

Rated excitation current, A from 300 to 3,000

Rated excitation voltage, V from 120 to 450

Rectifier transformer supply voltage, kV 6.3; 10.5; 13.8; 15.75; 20

Protection class IP21, IP22, IP23 or other upon request of the customer

Climatic version NF, U, Т

Location category 4

Generator and transfer protections (as per ANSI Code), integrated in the excitation systems or as a separate cabinet*: � overexcitation protection (24); � positive-sequence undervoltage protection (27); � reverse power protection (32); � excitation loss protection (40); � negative-sequence current protection (46); � phase-to-phase fault current protection (50); � generator breaker failure protection (50BF); � voltage-dependent current protection (51V); � stator winding earth fault protection* (51N, 59N); � generator overvoltage protection (59); � rotor earth fault protection (64); � generator’s longitudinal differential protection* (87); � rectifier transformer’s protections; � other protections as agreed upon with the customer.

*Supplied optionally upon request of the customer.

STS(N) 1 (2) P(E) XX - XXX - 2,5 NF (U, Т) 4

location category

climatic version

voltage forcing ratio

rated rectified current, A

rated voltage, V

P – forced coolingE –natural cooling

number of control channels for control and power parts

STS – self-exitation STSN – idepended power supply

A backup excitation input cabinet (ShVRV) can be supplied based on a supplementary agreement.

Page 26: Hydraulic Turbines

26

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

5. TURBOGENERATOR LIfE SUPPORT SYSTEMS5.1. Air cleaner and air recirculation unit

The air cleaner and air recirculation unit is designed to run in conjunction with TK-series open loop ventilation turbogenerators, and serves to clean and pre-heat air flowing into the generator.

The air flowing into the generator is heated by means of utilizing heat removed from operational losses. The cooling air recirculation system ensures generator start-up and operations within a temperature range of 60 °C below zero to 5 °C above zero.

Climatic version – NF.

Category of location – 3.

The air-mixing chamber should be located inside the generator container, and the air cleaning chamber should be stationed on the container roof.

Parameters and performance data Norms

Rated capacity of air flow, m3/hour 4.68

Efficiency of dust particles removal, size 10 mkm and more, % 98

Hydraulic friction, Pa 415

Module weight, kg 1,290

5.2. Water recirculation devices in air coolers

The devices are designed to arrange closed loop water recirculation in air coolers of T32 generators preventing condensation during cold seasons.

Performance data of devicesfor turbogenerators

20 and 32 MWfor turbogenerators

25 and 63 MW

Maximum water flow, m3/hour 170 250

Size, mm 2,583х2,720х1,850 2,640х2,784х1,832

Weight, kg 2,600 2,800

5.3. Oil supply device for turbogenerator bearings

The oil supply device is designed to provide lubrication to bearings of TS-20, T-16, and T-25 turbogenerators with the capacity of 20-32 MW during their joint operation with a gas turbine.

Performance data of device Norms

Oil flow rate for 2 bearings, l/min 110

Oil pressure at input of bearings, MPa min 0,03, max 0,1

Size, mm 3,450х3,120х980

Weight, kg 4,290

Page 27: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

27

6. TWO POLE SYNCHRONOUS MOTORS, HIGH-SPEED

6.1. STDM-series motors with 630…2,000 kW capacities

STDM-series synchronous turbomotors with the capacity of 630...2,000 kW with 50 Hz AC three phase power supply are designed to operate pumps, compressors, gas pressurizers, air blowers and other fast-running devices operated in the enclosed rooms with explosion-proof atmospheres in conditions of temperate climates.

Embodiment IM 7211, IM 7311

Cooling system motors with closed-loop ventilation – air cooling, with integrated air coolers operated on fresh water (or on sea water, as greed upon with the manufacturer)

motors with open-loop ventilation - air cooling, heated air is discharged through louvers in the stator casing

Cooling method closed-loop ventilation - ICW37A71

open-loop ventilation - IC31

Excitation system from digital thyristor excitation systems STSN or VTE10-315-series analog thyristor exciters (on request)

Start direct or reactance start, depending on the value of flywheel moments of driven equipment. Frequency starts from thyristor frequency converters (thyristor starter) are possible -as agreed upon with the manufacturer.

Protection level closed-loop ventilation - IР44open-loop ventilation - IР22

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, thermal control sensors, pressure switch sensor, foundation fastenings, mounting equipment, spare parts, and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage,

VRotation speed, rpm Efficiency, % Weight, kg

STDM-630-2R NF4 630 6000 3000 95.9 3800

STDM-630-2R NF4 630 10000 3000 95.7 3800

STDM-630-2Z NF4 630 6000 3000 95.9 4400

STDM-630-2Z NF4 630 10000 3000 95.7 4400

STDM-800-2R NF4 800 6000 3000 96.1 4000

STDM-800-2R NF4 800 10000 3000 95.9 4000

STDM-800-2Z NF4 800 6000 3000 96.1 4600

STDM-800-2Z NF4 800 10000 3000 95.9 4600

STDM-1000-2R NF4 1000 6000 3000 96.5 4500

STDM-1000-2R NF4 1000 10000 3000 96.1 4500

STDM-1000-2Z NF4 1000 6000 3000 96.5 5000

STDM-1000-2Z NF4 1000 10000 3000 96.1 5000

STDM-1250-2R NF4 1250 6000 3000 96.9 6000

STDM-1250-2R NF4 1250 10000 3000 96.5 6000

STDM-1250-2Z NF4 1250 6000 3000 96.9 6400

STDM-1250-2Z NF4 1250 10000 3000 96.5 6400

STDM-1600-2R NF4 1600 6000 3000 97.0 6200

STDM-1600-2R NF4 1600 10000 3000 96.7 6200

STDM-1600-2Z NF4 1600 6000 3000 97.0 7000

STDM-1600-2Z NF4 1600 10000 3000 96.7 7000

STDM-2000-2R NF4 2000 6000 3000 97.0 6600

STDM-2000-2R NF4 2000 10000 3000 96.9 6600

Page 28: Hydraulic Turbines

28

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

STDM-2000-2Z NF4 2000 6000 3000 97.0 7500

STDM-2000-2Z NF4 2000 10000 3000 96.9 7500

STDM - XXXX - 2 R (Z) NF 4

category of location

climatic version

R-open-loop ventilation,Z-closed-loop ventilation

number of poles

capacity, kW

three phase synchronous modernized motor

Page 29: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

29

6.2. STD - series motors with 2,500...12,500 kW capacities

STD-series synchronous turbomotors with the capacity of 2,500...12,500 kW with 50 Hz AC three phase power supply are designed to operate pumps, compressors, gas pressurizers, air blowers and other fast-running devices operated in the enclosed rooms with explosion-proof atmospheres in conditions of temperate climates.

Embodiment IM 7211, IM 7311

Cooling system motors below 8,000 kW and 12.5 MW – air cooling, closed- or open-loop

10 MW Motors - air cooling, closed-loop

motors with closed-loop ventilation have integrated air coolers operated on fresh water (or on sea water, as greed upon with the manufacturer)

in motors with open-loop ventilation, heated air is discharged through louvers in the stator casing

motors with the capacity of 6,300; 8,000 kW with open-loop ventilation are manufactured with integrated coarse and fine air intake filters and ducts for air removal outside the service area

Cooling method closed-loop ventilation - ICW37A71

open-loop ventilation - IC31

Excitation system from digital thyristor excitation systems STSN or VTE10-315-series analog thyristor exciters (on request), or from brushless exciters type BVU

Start direct or reactance start, depending on the value of flywheel moments of driven equipment. Frequency starts from thyristor frequency converters (thyristor starter) are possible -as agreed upon with the manufacturer

Protection level closed-loop ventilation - IР44open-loop ventilation - IР22

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, thermal control sensors, pressure switch sensor, foundation fastenings, mounting equipment, spare parts, and operation documents. On customer’s request, the motor can be equipped with excitation device, soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage,

VRotation speed, rpm Efficiency, % Weight, Kg

STD-2500-2R NF4 2500 6000 3000 97.2 10000

STD-2500-2R NF4 2500 10000 3000 97.0 10000

STD-2500-2Z NF4 2500 6000 3000 97.2 11100

STD-2500-2Z NF4 2500 10000 3000 97.0 11100

STD-3150-2R NF4 3150 6000 3000 97.3 11060

STD-3150-2R NF4 3150 10000 3000 97.2 11060

STD-3150-2Z NF4 3150 6000 3000 97.3 12300

STD-3150-2Z NF4 3150 10000 3000 97.2 12300

STD-4000-2R NF4 4000 6000 3000 97.5 11580

STD-4000-2R NF4 4000 10000 3000 97.4 11580

STD-4000-2Z NF4 4000 6000 3000 97.5 12920

STD-4000-2Z NF4 4000 10000 3000 97.4 12920

STD-4000-2RG NF4 4000 6000 3000 97.5 11710

STD-4000-2RG NF4 4000 10000 3000 97.4 11710

STD-5000-2R NF4 5000 6000 3000 97.6 13700

STD-5000-2R NF4 5000 10000 3000 97.5 13700

STD-5000-2Z NF4 5000 6000 3000 97.6 14700

STD-5000-2Z NF4 5000 10000 3000 97.5 14700

STD-6300-2 NF4 6300 6000 3000 97.6 21390

STD-6300-2 NF4 6300 10000 3000 97.5 21100

STD-6300-2RB NF4 6300 6000 3000 97.6 22830

Page 30: Hydraulic Turbines

30

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

STD-6300-2RB NF4 6300 10000 3000 97.5 22130

STD-6300-2R NF4 6300 6000 3000 97.6 22000

STD-8000-2 NF4 8000 6000 3000 97.9 23950

STD-8000-2 NF4 8000 10000 3000 97.7 23000

STD-8000-2R NF4 8000 6000 3000 97.9 23950

STD-8000-2R NF4 8000 10000 3000 97.7 23000

STD-8000-2RB NF4 8000 6000 3000 97.9 23950

STD-8000-2RB NF4 8000 10000 3000 97.7 23000

STD-10000-2 NF4 10000 6000 3000 97.8 26520

STD-10000-2 NF4 10000 10000 3000 97.9 26000

STD-12500-2 NF4 12500 6000 3000 97.9 29500

STD-12500-2 NF4 12500 10000 3000 97.8 28900

STD-12500-2R NF4 12500 6000 3000 97.9 29500

STD-12500-2R NF4 12500 10000 3000 97.8 28900

STD - XXXX - 2 R (Z) G (B) NF 4

category of location

climatic version

B-with side outputs G-for EGPU drive (only for STD-4000-2GR NF4)

R-open-loop ventilation,Z-closed-loop ventilation

number of poles

capacity, kW

three phase synchronous motor

Page 31: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

31

6.3. STD motors, special version

STD-series special synchronous turbomotors with 50 or 60 Hz AC three phase power supply are designed to operate pumps, compressors, gas pressurizers, air blowers and other fast-running devices.

Embodiment IM 7211

Cooling system motors below 8,000 kW – air cooling, closed- or open-loop

10,000 kW Motors - air cooling, closed-loop

motors with closed-loop ventilation have integrated air coolers operated on fresh or sea water

in motors with open-loop ventilation, heated air is discharged through louvers in the stator casing

Cooling method closed-loop ventilation – ICW37A71 open-loop ventilation – IC31

Excitation system from digital thyristor excitation systems STSN or VTE10 315-series analog thyristor exciters (on request)

Start direct start from full mains voltage or reactance start, depending on the value of flywheel moments of driven equipment. Frequecny starts from thyristor frequency converters (thyristor starter) are possible - as agreed upon with the manufacturer

Protection level closed-loop ventilation – IР44 open-loop ventilation – IР22

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, exciter, electric heaters for motors in tropical versions, foundation fastenings, mounting equipment, spare parts for exciter and motor, and operation documents.

Type of motor Capacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, Kg

50 Hz

STD-1000-2 Т4 1000 10000 3000 95.8 6980

STD-1250-2 Т4 1250 11000 3000 96.3 7580

STD-1600-2 Т4 1600 6000 3000 96.6 7980

STD-1600-2 Т4 1750 6300 3000 96.4 7980

STD-1600-2 Т4 1600 6600 3000 96.4 7980

STD-1600-2 Т4 1600 11000 3000 96.5 7980

STD-1600-2 Т4 1600 10000 3000 96.4 7980

STD-3150-2 Т4 3150 11000 3000 96.7 12300

STD-4000-2 Т3 4000 6600 3000 97.0 14700

STD-4000-2 Т3 4000 11000 3000 96.9 14700

STD-10000-2 Т3 10000 11000 3000 97.7 29700

STD - XXXX - 2 Т 3

category of location

climatic version

number of poles

capacity, kW

three phase synchronous motor

Page 32: Hydraulic Turbines

32

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

60 Hz

STD-800-3600 Т4 800 6000 3600 95.3 5130

STD-1000-3600Р NF4 1000 10000 3600 95.0 5600

STD-1600-3600 Т4 1600 6000 3600 96.6 7580

STD-1600-3600 Т4 1600 10000 3600 96.2 7580

STD-2500-3600 Т4 2500 10000 3600 96.7 11100

STD-3150-3600Z NF4 3150 6000 3600 96.6 12285

STD-10000-3600 NF4 10000 6000 3600 97.5 26800

STD - XXXX - 3600 R (Z) Т (NF) 4

category of location

climatic version

R-open-loop ventilation, Z-closed-loop ventilation

rotation speed, rpm

capacity, kW

three phase synchronous motor

Page 33: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

33

6.4. STDP-series motors, explosion proof

STDP-series synchronous turbomotors with the capacity of 1,250...12,500 kW with 50 Hz AC three phase power supply are designed to operate pumps, compressors, gas pressurizers, air blowers and other fast-running devices in explosion dangerous rooms of all classes (except for explosion dangerous areas of outside installations of class V-IG).

Embodiment IM 7211

Cooling system air cooling, closed-loop

10,000 kW Motors - air cooling, closed-loop

air is cooled with two sections of integrated air coolers operated on fresh or sea water

In motors with open-loop ventilation, heated air is discharged through louvers in the stator casing

Cooling method ICW37A71

Excitation system from brushless exciters of BVUP series

Start direct start from full mains voltage or reactance start, depending on the value of flywheel moments of driven equipment

Protection level IР44

Explosion protection type and level IExpxIIT5X

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, brushless excitation of BVUP series, thermal control sensors, switch of type DN 2.5, resistance level control unit BKS-3I, foundation fastenings, mounting equipment, spare parts to the motor, operation documents. On customer’s request, the motor can be equipped with excitation control cabinet, soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

STDP-1250-2 NF4 1250 6000 3000 96.5 7030

STDP-1250-2 NF4 1250 10000 3000 96.2 7030

STDP-1600-2 NF4 1600 6000 3000 96.7 7630

STDP-1600-2 NF4 1600 10000 3000 96.6 7630

STDP-2000-2 NF4 2000 6000 3000 96.9 8030

STDP-2000-2 NF4 2000 10000 3000 96.9 8030

STDP-2500-2 NF4 2500 6000 3000 96.8 11150

STDP-2500-2 NF4 2500 10000 3000 96.6 11150

STDP-3150-2 NF4 3150 6000 3000 97.1 12350

STDP-3150-2 NF4 3150 10000 3000 96.8 12350

STDP-4000-2 NF4 4000 6000 3000 97.2 12970

STDP-4000-2 NF4 4000 10000 3000 96.9 12970

STDP-5000-2 NF4 5000 6000 3000 97.3 14750

STDP-5000-2 NF4 5000 10000 3000 97.2 14750

STDP-6300-2 NF4 6300 6000 3000 97.4 21600

STDP-6300-2 NF4 6300 10000 3000 97.4 21600

STDP-6300-2B NF4 6300 6000 3000 97.4 21950

STDP-6300-2B NF4 6300 10000 3000 97.4 21750

STDP-8000-2 NF4 8000 6000 3000 97.6 23000

STDP-8000-2 NF4 8000 10000 3000 97.6 23000

STDP-8000-2B NF4 8000 6000 3000 97.6 22800

STDP-8000-2B NF4 8000 10000 3000 97.6 23000

STDP-10000-2 NF4 10000 6000 3000 97.7 27000

STDP-10000-2 NF4 10000 10000 3000 97.6 26500

STDP-12500-2 NF4 12500 6000 3000 97.7 29500

STDP-12500-2 NF4 12500 10000 3000 97.7 28900

Page 34: Hydraulic Turbines

34

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

STDP - XXXX - 2 B NF 4category of location

climatic version

with side outputs

number of poles

capacity, kW

three phase synchronous motor, ventilated

Page 35: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

35

6.5. SDG2 motor to operate gas pressurizers

SDG2 synchronous turbomotor with 50 or 60 Hz AC three phase power supply is designed for driving natural gas pressurizer EGPU at gas compressor plants.

Embodiment IM 7311

Cooling system air cooling, open-loop, with fans on shaft and additional axial fan installed on casing

Cooling method IC31

Excitation system from digital thyristor excitation systems STSN or VTE630/150T-series analog thyristor exciters (on request)direct, reactance-free asynchronous starts from full mains voltage are possible

Protection level IР44

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, exciter, foundation fastenings, mounting equipment, spare parts exciter and motor operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V cos Rotation speed, rpm

Efficiency, %

Weight, Kg

SDG2-12500-2R NF3.1 12500 10000 0,9 3000 97.8 36000

SDG2 - 12500 - 2 Р NF 3.1

category of location

climatic version

open-loop ventilation

number of poles

capacity, kW

two-pole synchronous motor to operate gas pressurizer

Page 36: Hydraulic Turbines

36

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

6.6. RVSD frequency-regulated, explosion proof synchronous motor with 14,000 kW capacity

RVSD-14000-2R Nf4 electric motor with open loop type ventilation is a part of frequency regulated electric drive feeding from the thyristor frequency converter. It is designed to drive centrifugal mechanisms in explosion hazard zones of the 1st and 2nd class under Russian GOST 51330.9. 50 or 60 Hz AC three phase power supply.

Electric motor of this type can be used at pumping plants of oil-trunk pipelines or compressor plants at gas pipe lines instead of gas-turbine motors (as an alternative to gas turbine motors with lower efficiency).

The particular feature of RVSD-14000-2R Nf4 is than it is possible to regulate Rotation speed from 50 to 105 % (1,500-3,150 rpm), that allows supporting the required pressure in the oil pipeline and excluding excess demand energy.

Embodiment IM 7011

Cooling system air cooling, open-loop

Cooling method IC31

Excitation system from asynchronous brushless exciter with digital control system integrated in the converter

Start direct start from full mains voltage or reactance start, depending on the value of flywheel moments of driven equipment

Protection level IP44

Explosion protection type and level IExpxIIT5X. Purging and maintenance of differential static pressureinside the motor should be effected with a pressurizer fan installed in the air treatment unit

Rated operating conditions S1

On customer’s request, the motor can be equipped with frequency converter HV-VFD.

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

A pressurizer fan, an air cleaning unit and a thyristor frequency converter are not included in the delivery set.

Type of motorRated capacity,

kWRated voltage, V

Synchronous rotation speed, rpm

cos Efficiency,

%Weight, Kg

RVSD-14000-2R NF4 14000 6000 1500...3150 0.9 97.7 34400

RVSD - 14000 - 2 Р NF 4

category of location

climatic version

open-loop ventilation

number of poles

capacity, kW

frequency-regulated, explosion proof synchronous motor

Page 37: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

37

6.7. TDS motors with 20,000 and 31,500 kW capacities

TDS turbo-motors with 50 Hz AC power supply are designed to operate high-pressure compressors at metallurgical factories.

Embodiment IM 7321

Cooling system air-cooling, closed loop, with water air coolers

Cooling method ICW37A71

Excitation system from digital thyristor excitation systems STSN

Motor start frequency-regulated, from thyristor converter

Protection level IP44

Rated operating conditions S1

On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Manufactured in compliance with GOST R 52776-2007.

Delivery set includes: motor, exciter, starter, foundation fastenings, mounting equipment, spare parts to exciter and motor, and operation documents.

Type of motor Capacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, Kg

TDS-20000-2 NF4 20000 10000 3000 97.6 57300

TDS-31500-2 NF4 31500 10000 3000 97.5 82900

Note: weight of motors does not include weight of exciters.

TDS - XXXXX - 2 NF 4

category of location

climatic version

number of poles

capacity, kW

synchronous turbomotor

Page 38: Hydraulic Turbines

38

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

7. SALIENT POLE SYNCHRONOUS MOTORS

7.1. SDK2- and DSK-series compressor motors

SDK2- and DSK-series synchronous compressor motors with 50 or 60 Hz AC three phase power supply are designed to operate piston compressors and are used in oil refining, metallurgical, machinery and other industries.

Embodiment IM 5710 – console-type motors IM 7111 - SDK2 17 39 12F NF4

Cooling method IC01

Excitation system from digital thyristor excitation systems STSN or VTE10-315-series analog thyristor exciters (on request)

Protection level IP10

Rated operating conditions S1

On customer’s request, the motor can be equipped with soft starter SSM-HV, frequency converter HV-VFD.

Manufactured in compliance with GOST R 52776-2007, GOST 18200 and customer’s specific technical requirements.

Delivery set includes: motor, thyristor exciter, thermal control sensors, foundation fastenings, device for installation and removal of rotor, spare parts and operation documents.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

SDK2-16-24-12С NF4 315 6000 500 92.3 2460

SDK2-16-24-12С NF4 315 10000 500 91.9 2470

SDK2-16-29-12С Т4 315 3000 500 92.7 2750

SDK2-16-29-12С Т4 315 6000 500 92.7 2750

SDK2-16-29-14С NF4 (Т4) * 320 3000 514 93.0 3130

SDK2-16-29-14С NF4 (Т4) * 320 6000 514 93.0 3130

SDK2-16-29-12С Т4 * 400 6000 600 93.1 2750

SDK2-16-24-10С NF4 400 6000 600 93.9 2550

SDK2-16-24-10С NF4 400 10000 600 93.9 2670

SDK2-16-24-10С Т4 400 6000 600 93.5 2560

SDK2-16-29-12F NF4 400 6000 500 94.0 4100

SDK2-17-26-16К NF4 500 6000 375 93.0 3900

SDK2-16-36-12С NF4 500 6000 500 93.7 3250

SDK2-17-26-12С NF4 630 3000 500 93.7 3600

SDK2-17-26-12С NF4 630 6000 500 94.5 3600

SDK2-17-26-12С NF4 630 10000 500 94.5 3640

SDK2-17-26-12С Т4 630 3000 500 94.1 3550

SDK2-17-26-12С Т4 630 6000 500 94.1 3550

SDK2-17-26-12С Т4 630 6600 500 94.1 3550

SDK2-17-29-14С NF4 (Т4) * 630 3000 514 94.3 4030

SDK2-17-29-14С NF4 (Т4) * 630 6000 514 94.3 4030

SDK2-16-44-10С NF4 630 10000 600 95.0 3780

SDK2-16-44-10С Т4 710 6000 600 95.3 3800

SDK2-16-44-10С NF4 800 6000 600 96.0 3770

SDK2-17-39-12F NF4 1000 6000 500 95.0 5930

SDK2-17-39-12F NF4 1000 10000 500 94.0 5550

* 60 Hz motor

Page 39: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

39

SDK 2 17 (16) - XX - YY F (C) NF (Т) 4

category of location

climatic version

C-console version (no shaft),F - one support version (flange)

number of poles

stator core size, cm

size designation

series

synchronous compressor motor

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

DSK 173/16-16А NF4 315 3000 375 92.0 3220

DSK-315-500-6М NF4 315 6000 500 92.0 2460

DSK-315-500-10М NF4 315 10000 500 92.0 2410

DSK-400-600-6М NF4 400 6000 600 94.0 2544

DSK-400-600-10М NF4 400 10000 600 95.0 2630

DSK-630-500-6М NF4 630 6000 500 94.5 3400

DSK-630-500-10М NF4 630 10000 500 94.5 3420

DSK-710-600-6М NF4 (Т4) 710 6000 600 95.3 3854

DSK - XXX - YYY - 6 (10) М (А) NF (Т) 4

category of location

climatic version

modification index

voltage, kV

rotation speed, rpm

capacity, kW

synchronous compressor motor

Page 40: Hydraulic Turbines

40

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

7.2. SDKP2-series compressor explosion proof synchronous motors

SDKP2-series compressor explosion proof synchronous motors 50 or 60 HZ AC three phase with power supply are designed for operation in explosion dangerous areas for driving piston compressors and are used in oil refining, metallurgical, machine building and other industries.

Embodiment IM 5710

Cooling system open- or closed-loop ventilation

Cooling method closed-loop ventilation – ICW37A81 open-loop ventilation – ICW37A31

Excitation system from digital thyristor excitation systems STSN or VTE10-315-series analog thyristor exciters (on request)

Explosion protection type and level IExpxIIT5

Protection level IP44

Rated operating conditions S1

On customer’s request, the motor is equipped with exciter, soft starter SSM-HV, frequency converter HV-VFD. Manufactured in compliance with GOST R 52776-2007, GOST 18200 and customer’s specific technical requirements.

Delivery set includes: motor, air cooler and blowdown valve (for closed-loop ventilation), pressure switch sensors, thermal control sensors, device for rotor installation and removal, foundation fastenings, flanges (for closed-loop ventilation), spare parts, and operation documents

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm

Efficiency, %

Ventilation cycleWeight,

Kg

SDKP2-16-24-12С NF4 315 6000 500 92.2 closed-loop 3700

SDKP2-16-24-12С NF4 315 6000 500 92.2 open-loop 3240

SDKP2-16-24-12С NF4 315 10000 500 91.9 open-loop 3500

SDKP2-16-29-12С NF4 400 6000 500 93.0 closed-loop 4000

SDKP2-16-29-12С NF4 400 6000 500 93.0 open-loop 3540

SDKP2-16-36-14С Т2* 400 6000 514 93.2 open-loop 4600

SDKP2-16-36-12С NF4 500 6000 500 93.7 closed-loop 4650

SDKP2-16-36-12С NF4 500 6000 500 93.7 open-loop 4190

SDKP2-16-29-10С NF4 500 6000 600 94.0 closed-loop 4000

SDKP2-16-29-10С NF4 500 6000 600 94.0 open-loop 3540

SDKP2-17-26-16К NF4 500 6000 375 93.6 closed-loop 5675

SDKP2-17-26-12С NF4 630 6000 500 94.0 closed-loop 5210

SDKP2-17-26-12С NF4 630 6000 500 94.0 open-loop 4740

SDKP2-17-26-12С NF4 630 10000 500 93.8 open-loop 4880

SDKP2-17-31-12С NF4 710 10000 500 94.3 open-loop 5830

SDKP2-17-31-12С NF4 800 6000 500 94.5 closed-loop 5650

SDKP2-17-31-12С NF4 800 6000 500 94.5 open-loop 5180

* 60 Hz motor

SDKP2 2 - 16 (17) - XX - YY К NF (Т) 2 (4)

category of location

climatic version

console design (w/o shaft)

number of poles

stator core size, cm

size designation

series

synchronous motor, ventilated, compressor motor

Page 41: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

41

7.3. SDN general purpose motors

SDN synchronous motors with 50 or 60 Hz AC three phase power supply are designed to operate pump drive motors, running in pumps station system and other mechanisms.

Embodiment IM 7311

Cooling system air cooling, open-loop self-ventilation

Cooling method IC01

Excitation system from brushless exciter with digital control system or from brushless asynchronous exciter with the possibility to control the rotation speed

Protection level IP10

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, excitation system, temperature monitoring equipment, spare parts and accessories, and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V cos Rotation speed, rpm

Efficiency, %

Weight, Kg

SDN-1000-600 N3 1000 10000 0.9 600 95.0 9540

SDN-630-750 N3 630 10000 0.9 750 94.63 5765

SDN-1250-1000 NF4 1250 6000 0.9 1000 96.0 8100

SDN - XXX - YYY N, NF 3

category of location

climatic version

rotation speed, rpm

capacity, kW

synchronous motor

Page 42: Hydraulic Turbines

42

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

7.4. Vertical synchronous motors SVD for driving vertical hydraulic pumps

7.4.1. Vertical synchronous motors, series SVD 143, SVD 173, and SVD 215

Vertical synchronous motors, series SVD 143, SVD 173, and SVD 215, energized from 3-phase, 50 Hz, AC mains, are designed for driving hydraulic pumps operated in the structure of a pumping station and other arrangements.

Embodiment IM 8425

Cooling system air, self-ventilated, open-loop, with hot air discharge through shutter in the stator louvers

Cooling method ICA01

Excitation system by static thyristor exciters

Protection class IP23

Rated operating conditions S1

Upon request of the customer, the motors can be fabricated with contact rings for connection of the pump blades turning device and with oil coolers enabling the use of sea water. These requirements must be specified in the order.

The motors are manufactured in compliance with GOST R 52776-2007 standard and specific technical requirements of the customer.

Delivery set includes: the motor, excitation system, thermal control equipment, spare parts, installation devices kit, and operation documents.

Product type Power, kW Voltage, V cos Speed, rpm Efficiency, % Weight, kg

SVD 143-630-6-12 NF4 630 6000 0,9 500 94.3 7700

SVD 143-1000-6-12 NF4 1000 6000 0.9 500 94.5 8600

SVD 143-1250-6-12 NF4 1250 6000 0.9 500 95.0 9400

SVD 143-1000-6-10 NF4 1000 6000 0.9 600 94.3 8800

SVD 143-1600-6-10 NF4 1600 6000 0.9 600 95.3 10500

SVD 143-1250-6-8 NF4 1250 6000 0.9 750 94.6 8700

SVD 143-1600-6-8 NF4 1600 6000 0.9 750 95.1 9300

SVD 173-1600-6-16 NF4 1600 6000 0.9 375 95.0 13300

SVD 173-1600-6-12 NF4 1600 6000 0.9 500 95.2 12900

SVD 173-2000-6-12 NF4 2000 6000 0.9 500 95.3 13800

SVD 215-2500-6-16 NF4 2500 6000 0.9 375 95.5 20600

SVD 215-3150-6-12 NF4 3150 6000 0.9 500 95.4 22800

SVD 215-3150-6-10 NF4 3150 6000 0.9 600 95.0 21700

SVD 143 (173,215) - XXXX - Y - 8 (10, 12,16) (К) (М) NF 4

location category

climatic version

with sea water coolers

with contact rings

number of poles

rated line voltage, kV

rated motor shaft power, kW

outer diameter of stator core, cm

vertical synchronous motor

Page 43: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

43

7.4.2. Vertical synchronous motors, series SVD 325, SVD 375

Vertical synchronous motors, series SVD 325, SVD 375, energized from 3-phase, 50 Hz, AC mains, are designed for driving centrifugal and axial vertical hydraulic pumps operated in the structure of a pumping station.

Embodiment IM 8425

Cooling system closed-loop, by integrated fans, with water air coolers installed on the stator casing

Cooling method ICW37А81

Excitation system by static thyristor exciters

Protection class IP43 -With allowance for installation in a building structure chamber

Rated operating conditions S1

Upon request of the customer, the motors can be fabricated with an opening in the shaft for connection of the pump blades turning drive. This requirement must be specified in the order.

The motors are manufactured in compliance with GOST R 52776-2007 standard and specific technical requirements of the customer.

Delivery set includes: the motor, excitation system, thermal control equipment, spare parts, installation devices kit, and operation documents.

Product type Power, kW Voltage, V cos Speed, rpm Efficiency, % Weight, kg

SVD 325-5000-6-24 NF4 5000 6000 0.9 250 95.5 51400

SVD 325-5000-10-18 NF4 5000 10000 0.9 333 95.0 51000

SVD 325-5000-6-18 NF4 5000 6000 0.9 333 95.2 47400

SVD 325-5000-6-16 NF4 5000 6000 0.9 375 95.3 46400

SVD 325-5000-10-16 NF4 5000 10000 0.9 375 95.2 47200

SVD 325-8000-10-16 NF4 8000 10000 0.9 375 95.9 58300

SVD 375-8000-10-32 NF4 8000 10000 0.9 187.5 95.8 104200

SVD 375-10000-10-24 NF4 10000 10000 0.9 250 96.3 100300

SVD 375-12500-10-24 NF4 12500 10000 0.9 250 96.9 117400

SVD 375-12500-10-28 NF4 12500 10000 0.9 214.3 96.7 123600

SVD 325 (375) - XXXXХ - Y - 16 (18, 24, 28, 32) NF 4

location category

climatic version

number of poles

rated line voltage, kV

rated motor shaft power, kW

outer diameter of stator core, cm

vertical synchronous motor

Page 44: Hydraulic Turbines

44

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

7.5. Synchronous motors SDE2-15-34-6

Synchronous motors SDE are designed for operation from AC mains, 50 Hz, as a driving motor for converter sets of excavators and similar machinery.

Embodiment IM 1102

Cooling system motors with the axial-radial ventilation system with the forced cooling air supply from a top-mounted fan with an individual drive, which is installed on the top of the stator casing on the side of the contact rings

Cooling method open-loop ventilation - ICA06

Excitation system the motors are excited by thyristor exciters or cross-field exciters. Excitation system is not included in the delivery set.

Start direct, at the rated mains voltage, or from a transformer. Three motor starts with the 5-min. interval are allowed. Next start shall be after cooling of the motor down to the ambient temperature. Average number of motor starts during operation shall be not more than 10 times a day.

Protection class IP21

Rated operating conditions S1

The motors are manufactured in compliance with GOST R 52776-2007 standard and specific technical requirements of the customer.

Delivery set includes: the motor, set of spare parts and accessories, and operation documents.

Product type Power, kW Voltage, V cos Speed, rpm Efficiency, % Weight, kg

SDE2-15-34-6N2 h 630 mm; 500 mm 630 6000 0.9 1000 94.2 5100

SDE2-15-34-6T2 h 630 mm; 500 mm 630 6000 0.9 1000 94.2 5100

SDE2-15-34-6F2 h 630 mm; 500 mm 630 6000 0.9 1000 94.2 5100

SDE2-15-34-6T2 h 500 mm 630 6000 0.9 1000 94.2 5100

SDE2 - 15 - 34 6 N (F, Т) 2

location category

climatic version

number of poles

stator core length in cm

size number

excavator synchronous motor, series 2

Page 45: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

45

7.6. Synchronous motors SDEUM-16-28-6

Synchronous motors SDEUM are designed for operation from AC mains, 50 Hz, as a driving motor for converter sets of excavators and similar machinery.

Embodiment IM 1102

Cooling system air, in the self-ventilation mode. The motors are ventilated by the fan blades installed on the rotor with the cooling air intake from the excavator body and hot air discharge into the body.

Cooling method open loop ventilation – ICA01

Excitation system the motors are excited by thyristor exciters or cross-field exciters. Excitation system is not included in the delivery set.

Start direct, asynchronous, at the rated mains voltage. The motor is started when the generator is not loaded. Two successive cold starts of the motor are allowed (motors have the ambient air temperature). After two starts, there shall be a 30-min. pause. Average number of motor starts during operation shall be not more than 10 times a day.

Protection class IP10

Group of operating conditions in terms of the impact of the ambient mechanical factors

М25

Rated operating conditions S1

The motors are manufactured in compliance with GOST R 52776-2007 standard and specific technical requirements of the customer.

Delivery set includes: the motor, set of spare parts and accessories, and operation documents.

Product type Power, kW Voltage, V cos Speed, rpm Efficiency, % Weight, kg

SDEUM-16-28-6N2 750 6000 0.9 1000 95.0 5150

SDEUM-16-28-6F2 750 6000 0.9 1000 95.0 5150

SDEUM-16-28-6Т2 750 6000 0.9 1000 95.0 5150

SDEUM - 16 - 28 6 N (F, Т) 2

location category

climatic version

number of poles

stator core length in cm

size number

excavator synchronous motor, series 2

Page 46: Hydraulic Turbines

46

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

8. ExCITATION SYSTEMS fOR SYNCHRONOUS MOTORS

8.1. Excitation control cabinet for brushless exciters of synchronous motors (ShUVD)

Excitation control cabinet ShUVD-1E-60-6 and ShUVD-2Е-60-8 are designed for excitation control of motors STDP, STD, SDN and similar motors with the capacity up to 31,500 kW with brushless exciters.

ShUVD-1Е - two-channel system, one DECS-200 digital controller and one analog controller with parametric control;

ShUVD-2Е - two-channel system, two ARVSD digital controllers.

ShUVD are manufactured on the basis of digital microprocessor regulators and highly reliable foreign-made components and ensures: � automatic field injection at reactor or across-the-line starting of the motor; � automatic current control of brushless exciter of synchronous motors; � implementation of control functions and data; � connection to the top-level of control over Modbus protocol (RS-485); � protection of the excitation system’s equipment and motor (short-circuit protection of the inverter, off-design operation protection of the brushless exciter,

protection from loss of excitation, overload protection of the motor rotor, motor protection from long-running starting operation); � display panel with the Russian menu on the front panel of the cabinet for ease of diagnostics and exciter control (ShUVD-2Е); � two-channel version possible; � possibility to manufacture in accordance with the required dimensions, operating conditions, and specific requirements of the customer.

Protection level IP43, IP54

Climatic version NF

Category of location 4

Manufactured in compliance with GOST 21558-2009 and customer’s specific technical requirements.

Delivery set includes: � control cabinet; � supplying transformer OLS-1.25/6(10) N2 type -1 pcs.; � set of spare parts and accessories; � operation documents.

Basic technical parameters:

Rated voltage of exciter coil, V 60

Rated current, А 6

Current boosting ratio, relative unit 1.4 - 2.0

Duration of boosting, sec. 10 - 60

Rated supply voltage:

alternating, V ~ 220

operational, direct, V 220

ShUVD - 1(2) Е - XXX - YYY NF (О, Т) 3 (4)

category of location

climatic version

rated rectified current

rated rectified voltage

self-cooling

number in schematic design

control cabinet for exciter of the motor

Page 47: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

47

8.2. TRN 1P thyristor voltage regulator

TRN-1P-xxx-YYY-Nf4 thyristor voltage regulator is designed for supplying regulated three phase voltage to stator coil of a brushless asynchronous exciter for synchronous motors STDP, STD, SDN with the capacity up to 12,500 kW for operation in the local control mode or for external setting from frequency converter (VFD).

TRN 1P regulator ensures the following motor operation modes: � voltage boosting in the manual regulation mode within the maximum output voltage. Excitation boosting operates in case of voltage drop on the motor stator

below the setting; � local control of the voltage setting in the whole regulation range; � voltage setting control on the basis of the external setting; � operability in case of short-term (not more than 60 s) change in the mains voltage within 50 - 140 %; � relay boosting time limitation.

During operation in the remote control mode, regulator TRN 1 P ensures maintenance of the voltage in line with the external setting, e.g. from VFD.

Selection between the local and remote operation modes is effected with a switch on the front panel of the TRN 1P cabinet.

TRN 1P regulator has the following protections: � overheating protection of the power section of the regulator; � short-circuit protection of thyristors; � phase loss protection.

Manufactured in compliance with GOST 21558-2009 and customer’s specific technical requirements.

Basic technical parameters:

Rated output current, A 20-300

Limit output voltage, V 380

Current boosting ratio, min. 1.4

Max. boosting duration, s, max. 60

AC supply voltage for operating circuits (rated value), V 220

Permissible voltage deviations, % +10, -15

AC supply voltage frequency, Hz 50

Permissible frequency deviations, Hz -3, +2

Rated voltage for motor stator voltage measuring circuits (effective value), V 100

Rated current for motor stator current measuring circuits (effective value), A 5

Power consumed by the equipment:

220 V AC, kW, max. 0.3

From voltage measuring transformers (per phase), VA, max. 1

From current measuring transformers (per phase), VA, max. 1

TRN - 1 P - XXX - YYY - NF 4

category of location

climatic version

limit output supply voltage of the exciter stator coil, V

permissible long-term AC, A

forced thyristor cooling

number of channels

thyristor voltage regulator

Page 48: Hydraulic Turbines

48

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

8.3. Static thyristor excitation systems for synchronous motors type STSNDigital static thyristor excitation systems STSN are designed for power supply to excitant wiring and excitation current in synchronous electric

motors of STDM, STD, SDK, SDKP, DSK, TDS, and their analogues with power control level up to 31,500 kW.

Excitatory systems STSN provide excitation current control in synchronous electric motors under the following

conditions: � direct start; � operating with frequency transformer and smooth start equipment; � operating under normal and emergency conditions.

STSN excitatory system functions: � forced current – 1.4 - 2.0 x rated value; � limited duration and period of forced operating; � maintenance of excitatory current level, ±1 % precision level under the conditions of voltage fluctuations range 70 – 110 % of rated level or rotor

temperature change; � limited maximum and minimum excitation current; � suppression of excitation field when motor is offline, during power outages, or in presence of field suppression signal; � local and remote control of excitatory current; range – from minimum to maximum level; � operating under the conditions of short-term (up to 60 sec) supply voltage changes from 50 to 140 %; � reactive stator current regulation and power ration – in automatic mode; � connection to top level of automatic control systems.

Integrated protection systems: � thyristor transformer maximum current protection; � asynchronous movements protection; � starter resistor overheat protection; � field break protection; � prolonged start protection; � power supply phase outage protection; � power income voltage decrease protection; � power income frequency decrease protection; � i2t rotor of motor overheat protection; � DC chains isolation control.

Protection level IP21, IP41, IP54

Climatic version NF, U, Т

Category of location 3, 4

Manufactured in accordance with GOST 21558-2009 and customer's specific technical requirements.

Product type Power, kW Rated voltage, VRated rectified

current, Aforcing current ratio,

not less thanWeight (exciter + transformer),

kg

Exciters for STDM, STD, SDN, SVD, SDKP, SDK, DSK

STSN-1Е (2E)-48-315 15.1 48 315 1.6 300 + 323

STSN-1Е (2E)-60-315 18.9 60 315 1.6 300 + 364

STSN-1Е (2E)-75-315 23.6 75 315 1.6 300 + 379

STSN-1Е (2E)-115-315 36.2 115 315 1.6 300 + 580

STSN-1Е (2E)-150-315 47.3 150 315 1.6 300 + 618

STSN-1Е (2E)-230-315 72.5 230 315 1.6 300 + 839

STSN - 1 (2) P (Е) - XXX - YYY NF (U, Т) 3 (4)

category of location

climatic version

rated exciter current (rectified), A

rated rectified voltage, V

P – forced coolingE – self-cooling

number of channels

static thyristor system with independent power supply (auxiliary power supply via matching transformer)

Page 49: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

49

8.4. VTE 10-315 and VTE 630/150 T series analog thyristor exciters for synchronous motors

VTE 10-315/*T Nf4 (O4) series thyristor exciters with rated current of 315A are designed to supply power to the excitation coil, and to control the excitation currents of STDM, STD, SDK, SDKP, and DSK series synchronous electric motors.

VTE 10-315/*T Nf4 (O4) series thyristor exciters can be manufactured in three versions: � version 0 - standard (w/o module MR or module MRRT); � version 1 – with module MR; � version 2 – with module MRRT.

VTE 630/150T Nf3.1 (In=630A, Un=150V) thyristor exciter is designed for supplying power to excitation coil and excitation current control of motor SDG2 12500 2R NF3.1.

VTE 10-315 and VTE 630/150T series thyristor exciters can be manufactured for similar motors on customer’s request.

Protection level IP20

Exciters are Manufactured in compliance with GOST 24688 81 and customer’s specific requirements.

Delivery set of exciter VTE10-315/*T Nf4 (U4) includes: main module MO, anode module MA (for exciters with Un=150V and Un=230V), module with backup control system MR (for version 1, supplied on request), module with backup control system and current reverse MRRT (or version 2, supplied on request), module of starting resistors MPS, matching power transformer, set of spare pars and accessories, and operation documents.

Delivery set of exciter VTE 630/150T Nf3.1 includes: thyristor converter cabinet, control and monitoring cabinet, starting resistor cabinet, matching power transformer, set of spare pars and accessories, and operation documents.

* Rated voltages (Un): 48 V, 75 V, 115 V, 150 V, 230 V

Type of exciter Capacity, kW Rated voltage, VRated direct

current, A

Ratio of boosting current

Efficiency, %

Weight (exciter and starting resistance)

+ transformer, kg

Exciters for STDM, STD, SDKP, SDK, DSK

VTE10-315/48Т NF4 (О4) 15.1 48 315 1.80 91.4 350+390

VTE10-315/75Т NF4 (О4) 23.6 75 315 1.80 93.0 431+665

VTE10-315/115Т NF4 (О4) 36.2 115 315 1.80 94.1 505+865

VTE10-315/150Т NF4 (О4) 47.3 150 315 1.80 94.2 603+665

VTE10-315/230Т NF4 (О4) 72.5 230 315 1.80 95.3 643+865

Exciters for SDG 2-12500-2

VTE-630/150Т NF3.1 94.5 150 630 3.00 94.5 991+1500

VT Е 10 - XXX / YYY Т NF (U) 4 (3.1)

category of location

climatic version

connection to mains via transformer

rated rectified voltage, V

rated rectified current, A

number of modification

air self-cooling

thyristor exciter

Page 50: Hydraulic Turbines

50

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

9. ASYNCHRONOUS ExPLOSION PROOf MOTORS WITH A SHORT CIRCUITED ROTOR

9.1. VAO series motors

Asynchronous explosion proof VAO motors with 50 or 60 Hz AC power supply are designed to drive pumps, fans, smoke exhausters, air blowers and other mechanisms. they are used for transfer of hydrocarbons in gas and dust hazardous mines and in explosive areas of premises referred to as explosive categories 1, 2, 3 and groups T1, T2, T3, T4 (as per electric devices installation classification).

Embodiment IM 1001

Cooling system air-to-air, closed-loop ventilation

Cooling method IC0151

Explosion protection type and level IExdIIBT4 and PB ExdI - motors VAO2, VAO5

IExdeIICT4 - motors VAO3

IExdIIBT4 - motors VAO 560

2ExdIICТ3 - motors VAO 800

Protection level IP54

Rated operating conditions S1

The motors are produced in compliance with GOST R 52776-2007 and individual customer's performance specifications.

Design of motors is protected with utility patent No. 42922.

Delivery set includes: motor, thermal image temperature indicators or resistance temperature detectors, spare parts, bearing extractor (on request), and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorExplosion protection

markingCapacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

VAO2-450 low voltage motors

VAO2-450-200/380-2 N2 IExdIIBT4 200 380 3000 94.1 2370

VAO2-450-250/380-2 N2 IExdIIBT4 250 380 3000 94.3 2370

VAO2-450 motors, 3000 rpm

VAO2-450-160-2 N2 IExdIIBT4 160 6000 3000 92.36 1765

VAO2-450S-2 N2 (N5)IExdIIBT4

PB ExdI200 6000 3000 94.1 1760

VAO2-450S-2 N2 (N5)IExdIIBT4

PB ExdI200 6000 3600 93.6 1760

VAO2-450S-2 F2 (F5) IExdIIBT4 200 6000 3600 93.6 1760

VAO2-450S-2 Т2 (Т5)IExdIIBT4

PB ExdI200 6000 3000 94.1 1760

VAO2-450S-2 Т2 (Т5)IExdIIBT4

PB ExdI200 6000 3600 93.6 1760

VAO2-450М-2 N2 (N5)IExdIIBT4

PB ExdI250 6000 3000 94.3 1800

VAO2-450М-2 N2 (N5)IExdIIBT4

PB ExdI250 6000 3600 93.8 1800

VAO2-450М-2 F2 IExdIIBT4 250 6000 3600 93.8 1800

VAO2-450М-2 Т2 (Т5)IExdIIBT4

PB ExdI250 6000 3000 94.3 1800

VAO2-450М-2 Т2 (Т5)IExdIIBT4

PB ExdI250 6000 3600 93.8 1800

VAO2-450LА-2 Т3 IExdIIBT4 315 6600 3000 94.7 2055

VAO2-450LА-2 N2 (N5)IExdIIBT4

PB ExdI315 6000 3000 94.4 2050

Page 51: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

51

Type of motorExplosion protection

markingCapacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

VAO2-450LА-2 N2 (N5)IExdIIBT4

PB ExdI315 6000 3600 93.9 2050

VAO2-450LА-2 F2 (F5)IExdIIBT4

PB ExdI315 6000 3600 93.9 2050

VAO2-450LА-2 Т2 (Т5)IExdIIBT4

PB ExdI315 6000 3000 94.4 2050

VAO2-450LА-2 Т2 (Т5)IExdIIBT4

PB ExdI315 6000 3600 93.9 2050

VAO2-450-315-2D N2 IExdIIBT4 315 10000 3000 94.64 2350

VAO2-450LB-2 N2 (N5)IExdIIBT4

PB ExdI400 6000 3000 94.9 2330

VAO2-450LB-2 N2 (N5)IExdIIBT4

PB ExdI400 6000 3600 94.4 2330

VAO2-450LB-2 F2 IExdIIBT4 400 6000 3600 94.4 2330

VAO2-450LB-2 Т2 (Т5)IExdIIBT4

PB ExdI400 6000 3000 94.9 2330

VAO2-450LB-2 Т2 (Т5)IExdIIBT4

PB ExdI400 6000 3600 94.4 2330

VAO2-450LB-2 Т2 (Т5) IExdIIBT4 400 6600 3000 94.5 2320

VAO2-450-200-2D N2 IExdIIBT4 200 10000 3000 94.4 2080

VAO2-450 motors, 1500 rpm

VAO2-450-160-4 N2 IExdIIBT4 160 6000 1500 94.2 2045

VAO2-450-200-4 N2 (N5)IExdIIBT4

PB ExdI200 6000 1500 94.85 2250

VAO2-450-200/3-4 N2 IExdIIBT4 200 3000 1500 94.92 2250

VAO2-450-200-4D N2 IExdIIBT4 200 10000 1500 94.6 2160

VAO2-450-250-4 N2 (N5)IExdIIBT4

PB ExdI250 6000 1500 94.87 2470

VAO2-450-250-4D N2 IExdIIBT4 250 10000 1500 94.63 2380

VAO2-450-250/3,3-4 Т2 IExdIIBT4 250 3300 1500 94.92 2315

VAO2-450-315-4 N2 (N5)IExdIIBT4

PB ExdI315 6000 1500 95.43 2780

VAO2-450-315/3,3-4 Т2 IExdIIBT4 315 3300 1500 95.04 2505

VAO2-450-400-4 N2 (N5)IExdIIBT4

PB ExdI400 6000 1500 95.21 4330

VAO2-450-315-4D N2 IExdIIBT4 315 10000 1500 94.6 2680

VAO2-450-400-4D N2 IExdIIBT4 400 10000 1500 94.8 3100

VAO5-450 motors, 1500 rpm

VAO5-450-200-4 N2 IExdIIBT4 200 6000 1500 94.0 2140

VAO5-450-200-4 N5 PB ExdI 200 6000 1500 93.30 2090

VAO5-450-250-4 N2 IExdIIBT4 250 6000 1500 94.3 2285

VAO5-450-250-4 N5 PB ExdI 250 6000 1500 93.8 2240

VAO5-450-315-4 N2 IExdIIBT4 315 6000 1500 94.7 2585

VAO5-450-315-4 N5 PB ExdI 315 6000 1500 94.2 2530

VAO5-450-400-4 N2 IExdIIBT4 400 6000 1500 95.0 3155

VAO5-450-400-4 N5 PB ExdI 400 6000 1500 95.0 3105

Page 52: Hydraulic Turbines

52

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

Type of motorExplosion protection

markingCapacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

VAO2-560 motors

VAO2-560-400-8 N2 IExdIIBT4 400 6000 750 94.57 4130

VAO2-560-400-4 N2 (N5)IExdIIBT4

PB ExdI400 6000 1500 95.21 4440

VAO2-560-400-2D N2 IExdIIBT4 400 10000 3000 91.94 4190

VAO2-560-500-4 N2 (N5)IExdIIBT4

PB ExdI500 6000 1500 94.71 5200

VAO2-560-500-2 N2 IExdIIBT4 500 6000 3000 94.21 4150

VAO2-560-500-2D N2 IExdIIBT4 500 10000 3000 93.14 4380

VAO2-560-630-4 N2 (N5)IExdIIBT4

PB ExdI630 6000 1500 95.82 5370

VAO2-560-630-2 N2 IExdIIBT4 630 6000 3000 93.75 4400

VAO2-560-630-2D N2 IExdIIBT4 630 10000 3000 93.57 4850

VAO2-560-800-6 N2 IExdIIBT4 800 6000 1000 94.82 4950

VAO2-560-800-4 N2 IExdIIBT4 800 6000 1500 95.26 4750

VAO2-560-800-2 N2 IExdIIBT4 800 6000 3000 94.66 4870

VAO2-560-800-2D N2 IExdIIBT4 800 10000 3000 94.34 5280

VAO2-560-1000-2 N2 IExdIIBT4 1000 6000 3000 94.94 5250

VAO5-560 motors

VAO5-560-400-2D N2 IExdIIBT4 400 10000 3000 95.5 3490

VAO5-560-500-2 N2 IExdIIBT4 500 6000 3000 95.8 3400

VAO5-560-500-2D N2 IExdIIBT4 500 10000 3000 94.8 3810

VAO5-560-630-2D N2 IExdIIBT4 630 10000 3000 95.2 4100

VAO5-560-630-2 N2 IExdIIBT4 630 6000 3000 95.5 3865

VAO2-630 motors

VAO2-630-800-4 N2 (N5)IExdIIBT4

PB ExdI800 6000 1500 95.26 5000

VAO2-630-800-6 N2 IExdIIBT4 800 6000 1000 94.82 5000

VAO3-450 motors

VAO3-450S-2 N2 IIC IExdeIICT4 200 6000 3000 94.1 1760

VAO3-450М-2 N2 IIC IExdeIICT4 250 6000 3000 94.3 1800

VAO3-450LA-2 N2 IIC IExdeIICT4 315 6000 3000 94.4 2050

VAO3-450LB-2 N2 IIC IExdeIICT4 400 6000 3000 94.9 2330

VAO-560 motors

VAO-560-1000-2D N2 (NF4) IExdIIBT4 1000 10000 3000 95.9 4980

VAO-560-1250-2 N2 (NF4) IExdIIBT4 1250 6000 3000 95.9 5060

VAO-560-1250-2D N2 (NF4) IExdIIBT4 1250 10000 3000 95.9 5458

VAO-560-1600-2 N2 (NF4) IExdIIBT4 1600 6000 3000 96.2 5453

VAO-560-1600-2D N2 (NF4) IExdIIBT4 1600 10000 3000 96.2 5620

VAO-560-2000-2 N2 (NF4) IExdIIBT4 2000 6000 3000 96.5 5695

VAO-630 motors

VAO-630-1000-4 N2 (N5)1Ех d IIB T4 Gb

PB ExdI1000 6000 1500 95.7 6515

VAO-630-1250-4 N2 (N5)1Ех d IIB T4 Gb

PB ExdI1250 6000 1500 95.9 6905

VAO-630-1600-4 N2 (N5)1Ех d IIB T4 Gb

PB ExdI1600 6000 1500 96.1 7590

Page 53: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

53

Type of motorExplosion protection

markingCapacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

VAO-630-2000-4 N2 (N5)1Ех d IIB T4 Gb

PB ExdI2000 6000 1500 96.3 8395

VAO-630-1000-4D N2 (N5)1Ех d IIB T4 Gb

PB ExdI1000 10000 1500 95.6 6425

VAO-630-1250-4D N2 (N5)1Ех d IIB T4 Gb

PB ExdI1250 10000 1500 95.8 6695

VAO-630-1600-4D N2 (N5)1Ех d IIB T4 Gb

PB ExdI1600 10000 1500 96.0 7262

VAO-630-2000-4D N2 (N5)1Ех d IIB T4 Gb

PB ExdI2000 10000 1500 96.2 7450

VAO-800 motors

VAO-800-630-12 NF4 2ExdIICТЗ 630 6000 500 94.8 12755

VAO-800-630-12М NF4 (to drive mills)

2ExdIICТЗ 630 6000 500 95.15 12755

VAO-800-630-10 NF4 2ExdIICТЗ 630 6000 600 94.6 12000

VAO-800-800-10 NF4 2ExdIICТЗ 800 6000 600 94.9 12000

VAO-800-1000-12 NF4 2ExdIICТЗ 1000 6000 500 94.7 11530

VAO-800-1250-16NF4 2ExdIICТЗ 1250 6000 375 95.9 17645

VAO-800-1000-10 NF4 2ExdIICТЗ 1000 6000 600 95.5 13338

Advanced development: VAO5-560-4 N2.

VAO 2 (3, 5) - XXX LA (S, M, LB) - YY D N (F, NF, T) 2 (3, 4, 5) IIC

sub-group sign

category of location

climatic version

voltage 10 kV

number of poles

stand size

height of rotation axis, mm

series

explosion proof, asynchronous, ventilated

Page 54: Hydraulic Turbines

54

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

9.2. VАО-2500 and VАО-5000 motors

Asynchronous motors VAO-2500 and VAO-5000 with a three phase AC 50 Hz power supply are designed as drives of horizontal oil pumps and other quick-moving mechanisms in areas of explosion hazard and for external class 2 machinery (in compliance with GOST R IEC 60079-10-1-2008).

Embodiment IM 1001

Cooling system air-to-air system, closed-loop ventilation system

Cooling method ICA 0151

Explosion protection type and level IExdIIBT4 Gb

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007, GOST R IEC 60079-0, GOST R IEC 60079-1 and TU 3341-010-59162910-2007.

Delivery set includes: motor, spare parts, and maintenance documentation. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

VAO-2500-6000-2 NF4 (N2) 2500 6000 3000 96.8 9460

VAO-2500/10000-2 NF4 (N2) 2500 10000 3000 96.6 9460

VAO-5000-6000-2 NF4 (N2) 5000 6000 3000 97.3 14890

VAO-5000/10000-2 NF4 (N2) 5000 10000 3000 97.3 15150

VAO - XXXX - YYYY - 2 NF(N) 4 (2)

category of location according to GOST 15150

climatic version

number of poles

voltage, V

rated capacity, kW

explosion proof, asynchronous, ventilated

Page 55: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

55

9.3. VASO-series explosion proof vertical motors

VASO asynchronous explosion proof vertical motors with AC 380 V, 50 Hz power supply are designed to operate as a gearless drive of air coolers and water towers.

The motors may be used as part of electric speed controlled drives, in which Rotation speed is controlled by frequency converters (on special request).

Magneto-liquid sealer can be used in VASO-series motors.

Cooling system air cooling

Cooling method IC0141

Explosion protection type and level

IIExdIIBT4; IExdeIIBT4 or IExdeIICT3 - VASO4 motor

IExdIIBT4 or IExdeIICT4 – VASO5 motor

Protection level IP54 or IP55. In case of magnetoliquid sealer installation in motors VASO4, protection level is IP55

Rated operating conditions S1

Manufactured in compliance with GOST 52776-2007, GOST R 51330.0 and customer's specific technical requirements.

Delivery set includes: motor, spare parts, and operation documents. Upon customer's request, the motors may be delivered with magneto-liquid sealants. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motor Explosion protection markingCapacity,

kWVoltage, V

Rotation speed, rpm

Efficiency, % Mounting type Weight, Kg

VASO4-6,5-12 IExdIIBT4 6.5 380 500 82.0 IM 4011 200

VASO4-13-12 IExdIIBT4, IExdeIICT3 13 380 500 89.7 IM 4333 510

VASO4-15-12 IExdIIBT4 15 380 500 89.7 IM 4333 510

VASO4-22-14 IExdIIBT4, IExdeIICT3 22 380 428.6 89.7 M 9633 1110

VASO5-22-14 IExdIIBT4, IExdeIICT4 22 380 428.6 90.3 M 9633 780

VASO4-30-14 IExdIIBT4, IExdeIICT3 30 380 428.6 90.3 M 9633 1225

VASO4-30-32 IExdIIBT4 30 380 187.5 86.18 M 9633 1020

VASO5-30-14 IExdIIBT4, IExdeIICT4 30 380 428.6 91.7 M 9633 870

VASO4-37-24 IExdIIBT4, IExdеIIBT4, IExdeIICT3 37 380 250 89.33 M 9633 1580

VASO4-55-24 IExdIIBT4, IExdеIIBT4, IExdeIICT3 55 380 250 90.95 M 9633 1980

VASO4-75-24 IExdIIBT4, IExdеIIBT4, IExdeIICT3 75 380 250 91.85 M 9633 2342

VASO4-37-14 IExdIIBT4, IExdeIICT3 37 380 428.6 90.5 M 9633 1316

VASO5-37-14 IExdIIBT4, IExdeIICT4 37 380 428.6 90.7 M 9633 960

VASO5-37-24 IExdIIBT4 37 380 250 90.93 M 9633 1530

VASO5-55-24 IExdIIBT4 55 380 250 91.76 M 9633 1840

VASO5-75-24 IExdIIBT4 75 380 250 92.33 M 9633 2105

VASO4-75-34 IExdIIBT4 75 380 176.5 90.87 M 9633 3630

VASO4-90-24 IExdIIBT4 90 380 250 92.3 M 9633 2765

VASO 4 (5) - XX - YY N (F, NF) 1category of location

climatic version

number of poles

capacity, kW

series

explosion proof, asynchronous, special, ventilated

Page 56: Hydraulic Turbines

56

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

9.4. VAOV series vertical motors

VAOV series asynchronous vertical motors with three phase 50 HZ AC power supply are designed to operate shore pumps to maintain formation pressure (3,000 rpm) and oil-trunk pipeline booster pumps (1,500 rpm).

Embodiment IM 4011

Cooling system air-to-air, closed-loop ventilation

Cooling method IC0151

Explosion protection type and level

IExdIIBT4

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, monitoring sensors, spare parts, bearing extractor (upon the request), and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

VAOV-200-2 N2 200 6000 3000 93.02 1967

VAOV-250-2 N2 250 6000 3000 93.45 2022

VAOV-315-2 N2 315 6000 3000 94.2 2200

VAOV-400-2 N2 400 6000 3000 94.74 2450

VAOV-500-2 N2 500 6000 3000 95.4 2900

VAOV-400-4 NF1 400 6000 1500 95.0 3500

VAOV-400-4D NF1 400 10000 1500 94.5 3450

VAOV-800-4 NF1 800 6000 1500 95.7 6510

VAOV-800-4D NF1 800 10000 1500 95.4 7085

VAOV-1250-4 NF1 1250 6000 1500 96.0 8515

VAOV-1250-4D NF1 1250 10000 1500 95.9 8500

VAOV-2000-4 NF1 2000 6000 1500 96.6 10300

VAOV-2000-4D NF1 2000 10000 1500 96.2 10250

VAOV-2000-6D NF1 2000 10000 1000 96.45 15000

VAOV - XXX - 2 (4, 6) D NF (N) 1 (2)

category of location

climatic version

voltage 10 kV

number of poles

capacity, kW

explosion proof, asynchronous, ventilated, vertical

Page 57: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

57

10. ExPLOSION PROOf, THREE PHASE ASYNCHRONOUS MOTORS WITH A SHORT CIRCUITED ROTOR

10.1. DAZO4 - series ventilated motors

Asynchronous ventilated motors DAZO4-series with three phase AC 50 Hz power supply are designed to operate pumps, air blowers, fans, smoke exhausters, mills and other mechanisms operating in temperate climates, after such application is confirmed.

Embodiment IM 1001. Motors are connected with the driven equipment by couplings, transferring no thrust loads of the motor shaft

Cooling system air cooling, self-ventilation mode

Cooling method ICА01А61

Protection level IP44, DAZO4M motor - IP54

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, spline, foundation fastenings, bearing extractor (upon the request), thermal control sensors, spare parts and operational documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

1500 rpm

DAZO4-560Х-4D N1 1000 10000 1500 95.0 4520

DAZO4-560Х-4 N1 1250 6000 1500 95.5 4840

DAZO4-560Yk-4D N1 1250 10000 1500 95.3 5200

DAZO4-560Yk-4 N1 1600 6000 1500 95.8 5570

DAZO4-560Y-4D N1 1600 10000 1500 95.6 5580

DAZO4-560Y-4 N1 2000 6000 1500 96.0 6040

1000 rpm

DAZO4-560Х-6D N1 800 10000 1000 94.9 4610

DAZO4-560Х-6 N1 1000 6000 1000 95.5 4930

DAZOМ-560-79-6 N1 (to drive mills)

1000 6000 1000 95.0 6700

DAZO4-560Yk-6D N1 1000 10000 1000 95.2 5310

DAZO4-560Yk-6 N1 1250 6000 1000 95.8 5630

DAZO4-560Y-6D N1 1250 10000 1000 95.5 5670

DAZO4-560Y-6 N1 1600 6000 1000 96.0 6140

750 rpm

DAZO4М-560Х-8D N1 630 10000 750 94.4 5785

DAZO4М-560Х-8 N1 630 6000 750 94.7 5875

DAZO4-560Х-8 N1 630 3000 750 95.2 4690

DAZO4М-560Yk-8D N1 800 10000 750 94.7 6275

DAZO4М-560Yk-8 N1 800 6000 750 95.0 6325

DAZO4М-560Y-8D N1 1000 10000 750 95.0 6660

DAZO4М-560Y-8 N1 1000 6000 750 95.3 6690

DAZO4М-560-1250-8N1 1250 6000 750 95.5 7472

600 rpm

DAZO4-560ХК-10 N1 (with 2 terminal boxes)

400 3000 600 94.77 4200

DAZO4-560ХК-10 N1 400 6000 600 93.6 4200

DAZO4-560Х-10 N1 500 6000 600 94.1 4500

DAZO4-560Х-10D N1 500 10000 600 93.8 4510

DAZO4-560Yk-10 N1 630 6000 600 94.6 5260

Page 58: Hydraulic Turbines

58

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

DAZO4-560Yk-10D N1 630 10000 600 94.3 5280

DAZO4-560Y-10 N1 800 6000 600 94.9 5620

DAZO4-560Y-10D N1 800 10000 600 94.6 5650

500 rpm

DAZO4-560ХК-12 N1 315 6000 500 92.9 4200

DAZO4-560Х-12 N1 400 6000 500 93.4 4500

DAZO4-560Х-12D N1 400 10000 500 93.1 4500

DAZO4-560Yk-12 N1 500 6000 500 93.9 5250

DAZO4-560Yk-12D N1 500 10000 500 93.6 5260

DAZO4-560Y-12 N1 630 6000 500 94.4 5600

DAZO4-560Y-12D N1 630 10000 500 94.1 5610

DAZO 4 М - 560 XXX - YY N 1

category of location

climatic version

number of poles

rated capacity, kW (stator core size)

height of rotation axis, mm

modernized

series

asynchronous closed ventilated motor

Page 59: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

59

10.2. DAO-type ventilated motors

DAO-type asynchronous ventilated motors with 50Hz AC three phase power supply are designed for driving the equipment under heavy-duty start conditions in explosion proof and non-fire atmosphere.

Embodiment IM 1001

Cooling system air cooling

Cooling method IC0161

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, key, foundation fastenings, bearing extractor, thermal control sensors, spare parts, and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

DAO-1250-750-6 N1 1250 6000 750 95.5 17300

DAO-1250-1000-6 N1 1250 6000 1000 95.0 11640

DAO-2000-500-6 N1 2000 6000 500 95.7 15000

DAO-2000-1000-10 N1 2000 10000 1000 95.6 15350

Advanced development: DAO-2000-1000-6N1.

DAO - XXXX - YYY 6 (10) N 1

category of location

climatic version

voltage, kV

rotation speed, rpm

capacity, kW

asynchronous ventilated motor

Page 60: Hydraulic Turbines

60

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

10.3. AOD-type ventilated two-speed motors

AOD-type asynchronous ventilated two-speed motors with three phase AC 50 Hz power supply are designed to operate forced-draft mechanisms of thermal power stations.

Embodiment IM 1001. Motors are manufactured with two stator coils operated separately

Cooling system air cooling

Cooling method IC0161

Protection level IP54

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, foundation fastenings, bearing extractor, thermal control sensors, spare parts, and operation documents.

Type of motorCapacity,

kWVoltage, V

Synchronous rotation speed, rpm

Efficiency, % Weight, Kg

AOD-800Х-8/10 N1 630/400 6000 750/600 93.6/93.4 9330

AOD-800Y-6/8 N1 1600/1000 6000 1000/750 95.0/94.7 11770

AOD-1000/500-8/10 N1 1000/500 6000 750/600 94.6/93.97 19000

AOD-1250/725-8/10 N1 1250/725 6000 750/600 95.13/94.62 19000

AOD - 800 - Y (Х) 6/8 (8/10) N 1

category of location

climatic version

number of poles

motor size designation (stator core size)

height of rotation axis, mm

asynchronous ventilated two-speed

AOD - XXXX/XXX - 8/10 N 1

category of location

climatic version

number of poles

capacity, kW

asynchronous ventilated two-speed

Page 61: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

61

10.4. AZO - series closed-ventilation motors

AZO - series asynchronous closed ventilated motors with three phase AC 50HZ power supply are designed to operate compressors, pumps and high inertia mass mechanisms.

Embodiment IM 1001

Cooling system air-cooling, self-ventilation mode

Cooling method IC0151

Protection level IP44

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, thermal image temperature indicator, oiler, spare parts, bearing extractor (on the request), and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

AZO-450S-2 N1 (Т2) 200 6000 3000 94.1 1810

AZO-450М-2 N1(Т2) 250 6000 3000 94.3 1850

AZO-450LА-2 N1 (Т2) 315 6000 3000 94.3 1840

AZO-450LВ-2 N1 (Т2) 400 6000 3000 94.5 2160

AZO - 450 S (M, LA, LB) - 2 N (Т) 1 (2)

category of location

climatic version

number of poles

stator core size

height of rotation axis, mm

asynchronous closed-ventilation motor

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

AZO-450-200-4 N2 200 6000 1500 94.85 2275

AZO-450-200-4D N2 200 10000 1500 94.0 2440

AZO-450-250/660-2 N2 250 660/380 3000 94.58 1620

AZO-450-250-4 N2 250 6000 1500 94.87 2500

AZO-450-300-4 N2 300 6000 1500 94.72 2820

AZO-560-500-4 N2 * 500 6000 1500 95.0 4700

AZO-560-500-2 N2 * 500 6000 3000 92.05 3900

AZO-560-630-6 Т2 630 6600 1000 95.1 4950

* Liquid oiling

AZO XXX - YYY - Z D N (Т) 1(2)

category of location

climatic version

voltage 10 kV

number of poles

capacity, kW

height of rotation axis, mm

asynchronous closed-ventilation motor

Page 62: Hydraulic Turbines

62

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

10.5. DAB special asynchronous motors

Asynchronous special DAB motors with three phase AC 50Hz power supply are designed to operate the screw compressors of drilling machines and other mechanisms.

Embodiment IM 1001

Cooling system air cooling

Cooling method IC0151

Protection level IP44

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, thermal image temperature indicator, oiler, spare parts, bearing extractor (on the request), and operation documents.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

DAB-450S-2 NF2 200 6000 3000 94.1 1760

DAB-450М-2 Т2 200 3300 3000 93.3 1910

DAB-450М-2 N2 250 6000 3000 93.9 1935

DAB - 450 S (М) - 2 NF (N, Т) 2

category of location

climatic version

number of poles

stator core size

height of rotation axis, mm

asynchronous motor for drilling rig

10.6. DA4 asynchronous motorsDA4 asynchronous motors with three phase AC 50Hz power supply are designed to operate pumps and other mechanisms.

Embodiment IM 1001

Cooling system air cooling, open-loop ventilation

Cooling method IC01

Protection level IP23

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, thermal control sensors, spare parts, and operation documents. On customer’s request, the motor can be equipped with soft starter SSM-HV and frequency converter HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm cos

Efficiency, %

Weight, Kg

DA4-560Х-8D N3 630 10000 750 0.79 94.9 5300

DA4-560У-8D N3 1250 10000 750 0.8 95.4 6150

DA 4 - 560 Х (N) - 8 D N 3

category of location

climatic version

voltage 10 kV

number of poles

motor size (stator core size)

height of rotation axis, mm

series

asynchronous motor

Page 63: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

63

10.7. DAZ series enclosed two-pole motorsDAZ series enclosed asynchronous motors with squirrel-cage rotor are designed for driving pumps, compressors, gas injectors, air compressors and other high-speed machines operated in the moderate climate regions. Motors with the capacity from 3,150 to 8,000 kW for energization from the 6,000 or 10,000 V mains.

Embodiment horizontal, on feet, with one working shaft end

Cooling system closed-loop, with water air coolers

Rated operating conditions S1

The motors are manufactured in compliance with GOST R 52776-2007 and specific technical requirements of the customer.

Delivery set includes: the motor, key, base plate mountings, spare parts, and operation documents.

Type of motorCapacity,

kWVoltage, V

Synchronous speed, rpm

Efficiency, % Weight, Kg

DAZ-3150/6000-NF4 3150 6000 3000 97.2 8700

DAZ-3150/10000-NF4 3150 10000 3000 96.9 8700

DAZ-4000/6000-NF4 4000 6000 3000 97.3 9200

DAZ-4000/10000NF4 4000 10000 3000 96.8 9500

DAZ-5000/6000-NF4 5000 6000 3000 97.5 10400

DAZ-5000/10000NF4 5000 10000 3000 97.0 10400

DAZ-6300/6000-NF4 6300 6000 3000 97.6 12500

DAZ-6300/10000NF4 6300 10000 3000 97.4 12500

DAZ-8000/6000-NF4 8000 6000 3000 97.6 14400

DAZ-8000/10000NF4 8000 10000 3000 97.4 14400

DAZ - ХХХХ / YYYYY NF 4

location category

climatic version

rotation speed, rpm

capacity, kW

enclosed asynchronous motor

Page 64: Hydraulic Turbines

64

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

10.8. VASV vertical water-cooled special motors

VASV asynchronous vertical special motors are designed to provide gearless drive to cooling tower fans from the mains of alternating 6,000 V current.

Embodiment IM 3731

Cooling system water-cooled (closed-loop water recirculation system is installed inside the stator)

Protection level IP54 or IP55

Rated operating conditions S1

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, spare parts, and operation documents. On customer’s request, the motor can be equipped with soft starters SMM-HV and frequency converters HV-VFD.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

VASV-200-52 N1 200 6000 115.4 86.7 11000

VASV - 200 - 52 N 1

category of location

climatic version

number of poles

capacity, kW

asynchronous vertical water-cooled special motor

10.9. DASO vertical motors

DASO asynchronous vertical motors with three phase AC 380V 50Hz power supply are designed to operate as a gearless drive for air-coolers and fans of cooling towers.

Embodiment IM 9633

Cooling system air cooling, open-loop ventilation

Protection level IP54

Rated operating conditions S1

The motors can be manufactured with the use of acid-resistant coating, glass-ceramic tribolubrication, and magnetoliquid sealer.

Manufactured in compliance with GOST R 52776-2007 and customer’s specific technical requirements.

Delivery set includes: motor, spare parts, and operation documents. On customer’s request, the motor can be equipped with electric heaters, temperature monitors, and magnetoliquid sealer.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm Efficiency, % Weight, Kg

DASO-50-34 N1 50 380 176.5 90.1 2000

DASO-75-34 N1 75 380/660 176.5 90.0 3400

DASO - XX - 34 N 1

category of location

climatic version

number of poles

capacity, kW

asynchronous, special, air-cooled motor

Page 65: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

65

10.10. Special asynchronous motors with variable frequency drive

10.10.1. Explosion proof asynchronous squirrel-cage motor DARB 1200 6 Nf2

With marking 2ЕхеНТ3Х in compliance with GOST R 52350.7 is designed for variable frequency drives for main equipment of drilling rigs (drill winch, mud pumps, and rotor).

Embodiment IIM1003 in compliance with GOST 2479 – with one operating cone shaft end, in compliance with GOST 12081 – with key, in compliance with GOST 23360 – with two bearing shields

Cooling system air cooling

Cooling method IСА 36 in compliance with GOST 20459

Protection level GOST 14254, GOST 17494:

terminal box - IP56;

cooling air inlet and outlet - IP23;

forced ventilation fan motor - IP 44

Rated operating conditions S1

The motor is manufactured with grease-lubricated SKF roller bearings. Design of bearing blocks enables refilling of grease without motor disassembly.

The motor is equipped with resistance temperature detectors with unique sensor curve 100P, measuring the temperature of stator coil and bearing blocks. To prevent the stator coil moistening, the motor is equipped with flexible heating elements, installed directly on the coil.

The motor is reversible and enables operation at any rotation direction in the whole range of rotation speed regulation.

The following is delivered complete with the motor: spare parts, including bearing extractor (on the customer’s request), and operation documents.

The motor is manufactured in compliance with GOST R 52776, GOST R 52350.0, and GOST R 52350.7.

Type of motorCapacity,

kWVoltage, V Rotation speed, rpm

Current frequency, HZ

Power factorEfficiency,

%Weight,

kg

DARB-1200-6 NF2 1200 660 1000 to 2000 50 0.84 95.0 3800

DARB - 1200 - 6 - NF2

climatic version and location category

number of poles

capacity, kW

asynchronous regulated motor for driving main equipment of drilling rigs

Page 66: Hydraulic Turbines

66

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

10.10.2. Asynchronous squirrel-cage DARG 3500 8 UM4

The motor is designed for operation as a part of electric propulsion system of a vessel with propulsion and steering column (PSC).

The motor enables operation on vessels with the unlimited navigating zone, including vessels of the ice navigation category of the maximum class “Icebreaker 6”.

The motor is reversible and enables operation at any rotation direction in the whole range of rotation speed regulation by changing the phase, value and frequency of the supplied power provided by the frequency converter.

Embodiment IM1001 in compliance with GOST 2479 – on feet, with one operating cylindrical shaft end, in compliance with GOST 12080– with key, in compliance with GOST 23360 – with two end shields

Cooling system air cooling

Cooling method through water-air cooler

coolant – sea water

Rated operating conditions S1

The following is delivered complete with the motor: spare parts, and operation documents.

The motor is manufactured in compliance with GOST R 52776 and Russian Maritime Register of Shipping «Rules of Technical Inspection for Building of Ships and Fabrication of Materials and Items for Ships».

Type of motor Capacity, kW Voltage, VRotation speed,

rpmCurrent

frequency, HZPower factor

Efficiency,%

Weight, kg

DARG-3500-8 ОМ4 3500 2х1800 750 50 0.85 97.0 14900

DARG - 3500 - 8 - UМ 4

climatic version and location category

number of poles

capacity, kW

asynchronous, regulated propulsion motor

10.10.3. Modernized arc-type stator asynchronous motor DADM 750-150 Nf1

Modernized arc-type stator asynchronous motor DADM with energization from the three-phase mains, AC, 50Hz. The motor is designed for driving pump jacks of low-flow oil wells. The motor is not designed for operation in a medium containing dangerous concentrations of explosion- and fire-dangerous and corrosive substances.

Embodiment IM1001

Cooling system air-air, closed-loop ventilation

Cooling method IC41

Rated operating conditions S1

The motors are manufactured in compliance with GOST R 52776-2007 and specific technical requirements of the customer.

Delivery set includes: the motor, base frame, spare parts, bearings extractor (upon request of the customer), and operation documents.

Type of motor Capacity, kW Voltage, V Rotation speed, rpm Efficiency,% Weight, kg

DADM 750-150 NF1 3.0 380/220 200 67.0 570

DADM - 750 - 150 - NF1

climatic version and location category

stator size, mm

motor diameter designation, mm

arc-type stator asynchronous motor

Page 67: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

67

10.11. Vertical asynchronous motors for driving hydraulic pumps

10.11.1. AVDN series vertical asynchronous motors

AVDN series vertical asynchronous motors with energization from the three-phase mains, AC, 50Hz are designed for driving hydraulic pumps.

Embodiment IM8425

Cooling system air, with self-ventilation , open-loop, with hot air discharge through the louvers in the stator casing

Cooling method ICA01

Protection class IP23

Rated operating conditions S1

Upon request of the customer, the motors can be fabricated with contact rings for connection of the pump blades turning device and with oil coolers enabling the use of sea water. This request must be specified in the order.

The motors are manufactured in compliance with GOST R 52776-2007 and specific technical requirements of the customer.

Delivery set includes: the motor, thermal control equipment, spare parts, set of installation devices, and operation documents. The motor can be equipped with the soft starter UPP-V V upon request of the customer.

Type of motor Capacity, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

AVDN 118-315-6-12 N3 315 6000 500 91.7 5300

AVDN 118-315-6-10 N3 315 6000 600 91.8 5000

AVDN 118-400-6-8 N3 400 6000 750 92.5 5100

AVDN 118-500-6,6-10 МТ3 500 6600 600 92.5 6200

AVDN 118-630-6-12 N3 630 6000 500 93.2 6700

AVDN 118-630-6-10 N3 630 6000 600 93.5 6200

AVDN 118-800-6-10 N3 800 6000 600 93.9 6700

AVDN 118-800-6-8 N3 800 6000 750 93.8 6200

AVDN 118-800-6,6-8 МТ3 800 6600 750 93.5 6700

AVDN 118-1000-6-8 N3 1000 6000 750 94.4 6700

AVDN 143-500-6-16 N3 500 6000 375 92.3 7300

AVDN 143-630-6-16 N3 630 6000 375 93.1 8600

AVDN 143-800-6-12 N3 800 6000 500 94.2 8200

AVDN 143-1000-3-12 N3 1000 3000 500 94.0 8900

AVDN 143-1000-6-12 N3 1000 6000 500 94.2 8900

AVDN 143-1000-6-10 N3 1000 6000 600 94.2 8300

AVDN 143-1250-6-10 N3 1250 6000 600 94.4 9000

AVDN 173-800-6-16 N3 800 6000 375 93.5 10700

AVDN 173-1000-6-16 N3 1000 6000 375 93.8 11800

AVDN 173-1250-6-16 N3 1250 6000 375 94.2 12900

AVDN 173-1000-6-12 КМТ3 1000 6000 500 93.5 11800

AVDN 173-1000-6,6-12 КМТ3 1000 6600 500 93.5 11800

AVDN 173-1250-3-12 N3 1250 3000 500 94.2 11600

AVDN 173-1250-6-12 N3 1250 6000 500 94.2 11600

AVDN 173-1600-6-12 N3 1600 6000 500 94.5 12300

AVDN 173-1600-6-10 N3 1600 6000 600 94.6 11600

AVDN 215-1600-6-16 N3 1600 6000 375 94.5 15100

AVDN 215-2500-6-16 N3 2500 6000 375 94.7 20300

AVDN 215-2500-6-12 N3 2500 6000 500 94.8 17700

Page 68: Hydraulic Turbines

68

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

AVDN 118 (143,173,215) - XXXX - Y - 8 (10,12,16) (К) (М) N (Т) 3

location category

climatic version

with sea water coolers

with contact rings

number of poles

rated line voltage, kV

rated motor shaft power, kW

outer diameter of core, cm

vertical asynchronous motor, standard type

10.11.2. AVDN and AVDZ series vertical asynchronous motors for nuclear power plants

and thermal power plants

AVDN and AVDZ series vertical asynchronous motors with energization from the three-phase mains, AC, 50Hz are designed for driving hydraulic pumps of the cooling systems at the nuclear power plants and thermal power plants.

Embodiment IM8021, IM8425

Cooling system air, with self-ventilation , open-or closed-loop

Cooling method ICA01, ICA21, ICW37A71, ICW37A81

Protection class IP23, IP44

Rated operating conditions S1

Upon request of the customer, the motors can be fabricated with oil coolers enabling the use of sea water. This request must be specified in the order.

The motors are fabricated in line with GOST R 52776-2007 and specific technical requirements of the customer.

Type of motor Capacity, kW Voltage, VRotation

speed, rpmEfficiency, %

Protection class

EmbodimentCooling method

Weight, kg

AVDZ 118-800-6-8 АМ3 800 6000 750 94.0 IP 44 IM8021 ICW37A71 6300

AVDN 118-1000-6-8 АМN3 1000 6000 750 94.1 IP 23 IM8425 ICA01 6100

AVDZ 173-1600-6-12 ТМ3 1600 6000 500 93.8 IP 44 IM8425 ICW37A71 15800

AVDN 173-1250-6-16 АN3 1250 6000 375 93.7 IP 23 IM8425 ICA01 12900

AVDZ 215-2000-6-16 Т3 2000 6000 375 94.0IP 23

IM8425ICA21

22100IP 44* ICW37A81*

AVDZ 215-2000-6-20 МТ3 2000 6000 300 94.5IP 23

IM8425ICA21

26100IP 44* ICW37A81*

AVDZ 215-2500-6-20 N3 2500 6000 500 94.5 IP54 IM8425 ICW37A71 21800

AVDZ 215-2500-6-20 N3 2500 6000 300 94.7IP 23

IM8425ICA21

25000IP 44* ICW37A81*

AVDZ 235-4000-10-16 КNF3 4000 10000 375 95.4 IP44 IM8425 ICW37A81 44200

AVDZ 235-5000-10-16 МNF3 5000 10000 375 95.5 IP44 IM8425 ICW37A81 45700

Delivery set includes: the motor, thermal control equipment, spare parts, set of installation devices, and operation documents.

* Ensured when the motor is installed in a building structure chamber.

Page 69: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

69

AVDZ(N) 118 (173,215) - XXXX - Y - 8 (12,16,20) (А) (C) (М) N (NFТ,ТМ) 3

location category

climatic version

with sea water coolers

with contact rings

for nuclear power plants

number of poles

rated line voltage, kV

rated motor shaft power, kW

outer diameter of core, cm

vertical asynchronous motor, enclosed or protected (standard) type

10.11.3. DAVD series vertical two-speed asynchronous motors

DAVD series vertical two-speed asynchronous motors with energization from the three-phase mains, AC, 50 Hz are designed for driving vertical hydraulic pumps.

Embodiment IM8425

Cooling system air, with self-ventilation , open-or closed-loop

Cooling method ICA01, ICW37A71, ICW37A81

Protection class IP 23, IP 44*

Rated operating conditions S1

Upon request of the customer, the motors can be manufactured with contact rings for connection of the pump blades turning device and with oil coolers enabling the use of sea water. This request must be specified in the order.

The motors are fabricated in line with GOST R 52776-2007 and specific technical requirements of the customer.

Delivery set includes: the motor, thermal control equipment, spare parts, set of installation devices, and operation documents.

Type of motor Capacity, kW Voltage, VRotation

speed, rpmEfficiency, %

Protection class

Cooling method

Weight, kg

DAVD 173-500/315-6-12/16 NF3 500/315 6000 600/500 90.8/90.0 IP 23 ICA01 10000

DAVD 173-1000/500-6-12/16 NF3 1000/500 6000 500/375 93.2/91.1 IP 23 ICA01 12400

DAVD 173-1600/1000-6-12/16 NF3 1600/1000 6000 600/500 93.6/93.5 IP 23 ICA01 13200

DAVD 215-2500/1600-6-20/24 М3 2500/1600 6000 300/250 94.0/93.0 IP 44 ICW37A71 29500

DAVD 235-3150/1600-6-20/24 NF3 3150/1600 6000 300/250 94.2/93.3 IP 44* ICW37A81 39900

DAVD 235-4000/2500-6-20/24 NF3 4000/2500 6000 300/250 94.5/93.6 IP 44* ICW37A81 41700

* Ensured when the motor is installed in a building structure chamber.

DAVD 173 (215,235) - ХХXX / YYYY - Z - 12/16 (20/24) (М) NF (М) 3, 4

location category

climatic version

equipped with sea water coolers

number of poles for first/second speed

rated line voltage, kV

rated motor shaft power for fist/second speed, kW

outer diameter of core, cm

vertical two-speed asynchronous motor

Page 70: Hydraulic Turbines

70

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

11. MOTORS fOR OPERATION AT NUCLEAR POWER PLANTS

11.1. Motors for driving main circulation pumps of nuclear power plants

11.1.1. Vertical closed asynchronous motor DAVZ-8000-6 AM U5

Vertical closed asynchronous motor DAVZ -8000-6 AM U5 with squirrel-cage rotor, energized from the three-phase mains, AC, 50Hz, is designed for driving main circulation pumps GCNA 1713 of power units VVER for nuclear power plants.

Embodiment IM 8721

Cooling system air cooling, closed loop with water coolers

Cooling method ICW37A71

Protection level IP55

Rated operating conditions S1

Manufactured according to TU 3381-025-59162910-2009.

Delivery set includes: motor, package of operation documents on the motor, package of operation documents on the components, package of drawings for installation devices, spare parts, and set of installation devices. .

Type of motor Operating modeCapacity,

kWVoltage, V Rotation speed, rpm

Efficiency, %

Weight, Kg

DAVZ-8000-6 АМ U5Cold water mode 8000

6000 100095.7

52250Hot water mode 5300 94.7

DAVZ - 8000 - 6 А М U 5

category of location

climatic version

equipped with sea water coolers

for nuclear power plants

number of poles

rated capacity, kW

asynchronous vertical closed motor

Page 71: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

71

11.1.2. Asynchronous vertical two-speed motor DAVDZ-7100/2800-10000-6/8 AM U5

Asynchronous vertical closed two-speed motor DAVDZ with squirrel-cage rotor, energized from the three-phase mains, AC, 50Hz, is designed for driving main circulation pumps GCNA-1391 of power units VVER for nuclear power plants.

Embodiment IM 8221

Cooling system air cooling, closed-loop with water coolers

Cooling method ICW37A71

Protection level IP55

Rated operating conditions S1

Manufactured according to TU 3381-026-59162910-2009.

Delivery set includes: motor, package of operation documents on the motor, package of operation documents on the components, package of drawings for installation devices, spare parts, and set of installation devices.

Type of motor Operating modeCapacity,

kWVoltage, V Rotation speed, rpm

Efficiency, %

Weight, Kg

DAVDZ-7100/2800-10000-6/8 АМ U5Cold water mode 7100/2800

100001000/750 95.0/93.0

45500Hot water mode 5000 1000 94.5

DAVDZ - 7100/2800 - 10000 - 6 /8 А М U 5

category of location

climatic version

equipped with sea water coolers

for nuclear power plants

number of poles

rated voltage, V

rated capacity, kW

asynchronous vertical two-speed closed motor

Page 72: Hydraulic Turbines

72

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

11.2. Motors for driving pumps and high-speed machines

11.2.1. Closed asynchronous motors DAZA

Closed two-pole asynchronous motors DAZA with squirrel-cage rotor are designed for driving pumps and other high-speed machines for operation at the nuclear power plants. Motors with the power of 1,600 kW for energization from the 6,000 V mains.

Embodiment horizontal, on feet, with one working shaft end. Motors with journal bearings with circulating lubrication system

Cooling system closed, with water coolers

Rated operating conditions S1

The motors are fabricated in line with GOST R 52776-2007 and specific technical requirements of the customer.

Delivery set includes: the motor, key, base plate mountings, spare parts, and operation documents.

Type of motor Capacity, kW Voltage, VSynchronous rotation

speed, rpmEfficiency, % Weight, kg

DAZA-1600/6000-NF4 1600 6000 3000 96.3 4938/5150*

* With base plate mountings

DAZA - 1600 / 6000 NF 4

location category

climatic version

voltage, V

capacity, kW

asynchronous closed motor

Page 73: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

73

12. ELECTRICALLY DRIVEN GAS COMPRESSOR UNITS (EGPU)

12.1. EGPU on the basis of electric drives fabricated under license of TMEIC; basic configuration of flow diagramFactors ensuring the improved reliability:

Due to the use of a frequency converter and electromagnetic suspension of the rotor, the reliability indicators and service life of EGPU are increased and the costs for maintenance and repair reduced, that is:

� Wear-out of mechanical and electrical equipment is reduced due to the absence of limitation for the number of starts and shutdowns (the use of a frequency converter as a soft starter);

� Probability of failures is reduced due to the smooth change in the operating conditions of the compressor workshop; � Direct connection “electric motor – pressure blower” is ensured due to the use of high-speed motors; � Torque multiplier is eliminated from the configuration of EGPU; � Lubrication system for the motor and compressor bearings is eliminated and therefore there is no possibility of ignition and no

necessity for oil stock; � Start-up readiness of the machine is improved; the start-up time is reduced; � Wear-out of the shaft necks of the motor and compressor is eliminated due to the use of magnetic bearings; � Due to the use of an automatic control system for EGPU and compressor workshop, the control accuracy is improved and the remote control of EGPU and compressor

workshop provided, which enables unmanned technology of the equipment maintenance; the costs for the maintenance personnel are reduced.

EGPU on the basis of electric drives fabricated under license of TMEIC; basic configuration of flow diagram.

EGPU components Main parametersEGPU-4.0/8200- 56/1.26(1.44)-R

Lysva-VOSTOK

EGPU-6.3/8200- 56/1.44-R Kedr

EGPU-8.0/8200- 56/1.44-R Lysva

EGPU-12.5/6500- 56/1.44-PCh-MP

Lysva

EGPU Manufacturer –

Elektrotyazhmash-Privod LLC

Drive rating, MW 4.0 6.3 8.0 12.5

Throughput capacity, million nm3/day 12.5 12 15 20

Rated speed of blower shaft, rpm 8200 8200 8200 6500

Embodiment Indoor

Сlimatic version as per GOST 15150

NF

EGPU weight, tons, (motor + blower) 34.5 38.1 39.5 48

Weight of heaviest unit, tons, not more than

22 22 22 25

EGPU overall dimensions, mm 5350х2200х2700 5350х2200х2700 6150х2100х2500 7000х3600х3200

ELECTRIC MOTOR Manufacturer -TMEIC /

Elektrotyazhmash-Privod LLC

Type Asynchronous

Rated Efficiency, % 97.3 96.7 97 97.5

Rotor speed, rpm 8200 8200 8200 6500

Speed range, % 50-105

Rated input Voltage, V 3300 6000 6660 7000

Rated current, А 870 747 852 1 245

Type of bearings Active electromagnetic suspension

Cooling type Air, open-loop

Specified life, hrs 200 000

Motor weight as supplied, tons 12.5 16.1 17.5 23

Overall dimensions of motor, mm 2600х2200х2700 2600х2200х2700 3200x2100x2500 3500x3600x3200

Page 74: Hydraulic Turbines

74

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

EGPU components Main parametersEGPU-4.0/8200- 56/1.26(1.44)-R

Lysva-VOSTOK

EGPU-6.3/8200- 56/1.44-R Kedr

EGPU-8.0/8200- 56/1.44-R Lysva

EGPU-12.5/6500- 56/1.44-PCh-MP

Lysva

BLOWER

Rated power consumed by blower, MW 3.89 6.10 7.20 12.00

Throughput capacity, million nm3/day 12.5 12.5 16.5 25.0

Polytrophic Efficiency, % 84 85.7 85.1 84.7

Rotor speed, rpm 8200 8200 8200 6500

Type of bearings Active electromagnetic suspension

Sealing type Dry, gasdynamic

Pressure ratio 1.26 1.44 1.44 1.44

Max. discharge pressure, MPa 5.49 5.49 5.49 7.45

Weight, tons 22 22 22 25

Overall dimensions, mm 2250х1840х1500 2250х1840х1500 2250х1840х1500 2700х2240х1800

FREQUENCY CONVERTER

Manufacturer -TMEIC / Elektrotyazhmash-Privod

LLC

Output power of converter, kVA 5924 9790 11161 16212

Rated current, А 900 785 895 1300

Rated voltage, V 3800 7200 7200 7200

Output voltage frequency, Hz 137/143.8 137/143.8 137/143.8 109.3/114.8

Efficiency, % (not less than) 97

Overall dimensions (LxBxH), mm 5900x1770x2550 9100x1770x2550 9100x1770x2550 9100x1770x2550

Weight, tons 11 22.2 22.2 22.2

HEAT EXCHANGER

Cooling fluid consumption, l/min 360 690 690 690

Weight, tons 2.4 2.4 2.4 2.4

Overall dimensions (LxBxH), mm 4900x1480x2475

Quantity, pcs 1 2 2 3

EGPU - 4.0 / 8200 - 56 / 1.26 (1.44) - Р Lysva-VOSTOK

conditional designation of machine

supplied for revamping compressor workshops of compressor plants

rated pressure ratio (compression ratio)

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas compressor unit

Page 75: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

75

12.2. EGPU on the basis of electric drives from MAN Diesel&Turbo, flow diagram – single unit (MOPICO and HOfIM) The design of MOPICO and HOFIM EGPU’s has no couplings and complex sealing as well as no lube system and gear. The machine is equipped with a high-speed asynchronous motor cooled by process gas. The common rotor of the compressor and motor is supported by two magnetic bearings. Depending on the operating flow rate and pressure, the systems can be supplied with a single or twin compressor unit (tandem), which is widely used in the oil and gas industry. In the latter case, two compressors symmetrically installed on the shaft prevent axial displacement of the rotor.

Benefits:

� safe for environment; no emissions of harmful substances; � minimal requirements for operation and maintenance; � small size and weight; � ideal solution for remote control and operation in the auto mode; � wide operating range due to the improved dynamic characteristics of the rotor.

Configurations for serial or parallel operation.

EGPU on the basis of MOPICO

EGPU components Main parametersEGPU 7.8/12000-128/1.80

(1.35)-R Lysva-MBM-7.8EGPU 8.2/8600-56/1.44-R

Lysva-MBM -8.2EGPU 14.5/9500-128/1.80 (1.35)-R Lysva-MBM -14.5

EGPU

Type of single unit MOPICO MOPICO MOPICO

Rated power, MW 7.8 8.2 14.5

Throughput capacity, million nm3/day 12.1 16.5 18.1

Rated Rotor speed, rpm 12000 8600 9500

Embodiment Indoor; recommended temperature: +5 °С

EGPU weight, tons 29.8 41.3 40

Weight of heaviest component, tons (not more than) 12 18 16

Overall dimensions, mm 7200x4400x3800 4950x4680x3600 7650x4870x4700

ELECTRIC MOTOR

Type M33 MGV1 RMB2-100 M43

Rated Efficiency, % 94 94.7 94

Rotor speed, rpm 12000 8400 9500

Speed range, % 32 - 105 40-105 32 - 105

Rated input Voltage, V 6000 5650 6000

Rated current, А 1000 1140 1800

Cooling type By process gas

Specified life, hrs 160000

Weight, tons 9.5 18 16

Page 76: Hydraulic Turbines

76

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

EGPU components Main parametersEGPU 7.8/12000-128/1.80

(1.35)-R Lysva-MBM-7.8EGPU 8.2/8600-56/1.44-R

Lysva-MBM -8.2EGPU 14.5/9500-128/1.80 (1.35)-R Lysva-MBM -14.5

NATURAL GAS BLOWER

Type RM40 RM50 RM50

Rated power consumed by blower, MW 7.8 8.271 14.5

Number of stages 2 2 2

Throughput capacity for serial connection of stages, million nm3/day 12.1 16.5 18.1

Throughput capacity for parallel connection of stages, million nm3/day 23.8 – 36.7

Polytrophic Efficiency, % 86 85 87

Rotor speed, rpm 12000 8400 9500

Pressure ratio for serial connection of stages 1.80 1.44 1.80

Pressure ratio for parallel connection of stages 1.35 – 1.35

Max. discharge pressure, MPa 13.5 5.49 13.5

Weight, tons 5.4 16 10

FREQUENCY CONVERTER

Output power of converter, kVA 10500 14000 19700

Rated current, А 1000 1350 1800

Rated voltage, V 6000 6000 6000

Output voltage frequency, Hz 200 143 160

Efficiency, % (not less than) 98 98 98

Overall dimensions (LxBxH), mm 9200x1700x2700 11400x1200x2530 14000x1700x2700

Weight, tons 10 13.5 13

HEAT EXCHANGER

Cooling fluid consumption, l/min 800 600 1000

Overall dimensions (LxBxH), mm 8400x2300x1900 4560x2220x2400 9700x2300x1900

2.2 3.5 2.5

EGPU - 7.8 / 12000 - 128 / 1.80 - R Lysva-MBM

conditional designation of machine

supplied for revamping compressor workshops of compressor plants

rated pressure ratio (compression ratio)

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas pumping unit

Page 77: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

77

EGPU on the basis of MOPICO

EGPU components Main parametersEGPU 7.8/12000-

148/3.00-R Lysva-MBKh-7.8

EGPU 7.8/12000- 222/9.00 (3.00)-R Lysva-MBKh-7.8

EGPU 14.5/9500- 167/3.00-R Lysva-

MBKh-14.5

EGPU 14.5/9500- 222/9.00 (3.00)-R Lysva-MBKh-14.5

EGPU

Type of single unit HOFIM HOFIM HOFIM HOFIM

Rated power, MW 7.8 7.8 14.5 14.5

Throughput capacity, million nm3/day 8.2 8.2 13.8 13.8

Rated rotor speed, rpm 12000 9500

Embodiment Indoor; recommended temperature: +5 °С

EGPU weight, tons 31 43 55 79

Weight of heaviest unit, tons, not more than 12 12 25 22

Overall dimensions, mm 7200x4400x3800 7200x4400x3800 6600x4870x4700 7650x4870x4700

ELECTRIC MOTOR

Type M33 M43

Rated Efficiency, % 94 94

Rotor speed, rpm 12000 9500

Speed range, % 32 - 105 32 - 105

Rated input Voltage, V 6000 6000

Rated current, А 1000 1800

Cooling type By process gas

Specified life, hrs 160000

Weight, tons 9.5 16

NATURAL GAS BLOWER

Type RB35 RB45

Rated power consumed by blower, MW 7.8 14.5

No. of casings 1 2 1 2

No. of working stages per casing, min/max min 3 / max 6 min 3 / max 6 min 3 / max 6 min 3 / max 6

Throughput capacity for serial connection of stages, million nm3/day 1.9 3.2

Throughput capacity for parallel connection of stages, million nm3/day – 3.3 – 4.5

Polytrophic Efficiency for serial connection of stages, % 83 84

Polytrophic Efficiency for parallel connection of stages – 80 – 80

Rotor speed, rpm 12000 9500

Pressure ratio for serial connection of stages

3.00 9.00 3.00 9.00

Pressure ratio for serial connection of stages – 3.00 – 3.00

Max. permissible discharge pressure, MPa 15.0 22.5 17.0 22.5

Weight, tons 12 12+12 25 22+20

Page 78: Hydraulic Turbines

78

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

EGPU components Main parametersEGPU 7.8/12000-

148/3.00-R Lysva-MBKh-7.8

EGPU 7.8/12000- 222/9.00 (3.00)-R Lysva-MBKh-7.8

EGPU 14.5/9500- 167/3.00-R Lysva-

MBKh-14.5

EGPU 14.5/9500- 222/9.00 (3.00)-R Lysva-MBKh-14.5

FREQUENCY CONVERTER

Output power of converter, kVA 10500 19700

Rated current, А 1000 1800

Rated voltage, V 6000

Output voltage frequency, Hz 200 160

Efficiency, % (not less than) 98

Overall dimensions (LxBxH), mm 9200x1700x2700 14000x1700x2700

Weight, tons 10 13

HEAT EXCHANGER

Cooling fluid consumption, l/min 800 1000

Overall dimensions (LxBxH), mm 8400x2300x1900 9700x2300x1900

Weight, tons 2.2 2.5

EGPU - 7.8 / 12000 - 1.48 / 3.00 - R Lysva-MBKh

conditional designation of machine

supplied for revamping compressor workshops of compressor plants

rated pressure ratio (compression ratio)

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas pumping unit

Page 79: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

79

12.3. Packaged modular EGPU’sEGPU’s are made in packaged modular configuration as individual transportable modules with a set of equipment and auxiliary systems.

Separate elements of EGPU have a packaged modular design of increased operational compatibility, which provides reduction of the scope construction and assembly works on the site, possibility for conduction of the required tests on the modules at the factory before shipment, and possibility for the assembly both outdoors and in an easy-to-assemble hangar-type shelter or in existing permanent buildings.

The EGPU delivery set includes: � natural gas pressure blower unit; � electric motor unit; � frequency converter unit; � automatic control system and auxiliary systems unit; � frequency converter cooling heat exchanger; � matching transformer.

EGPU components Main parametersEGPU-8.0/8200-56/1.44-PCh-MP-

BK EGPU -12.5/6500-56/1.44- PCh-

MP-BK

Manufacturer

EGPU -

Elektrotyazhmash-Privod LLC

Rated power, MW 8.0 12.5

Volume throughput capacity, million nm3/day 16.0 20.0

Сlimatic version as per GOST 15150 NF

Weight of heaviest unit, not more than, tons 25 30

Noise level at 1m to EGPU units, dBA 80

Full service life, hrs 200 000

MOTOR

ТМЕIC/- Elektrotyazhmash-

Privod LLC

Type of electric motor Asynchronous

Rated active power, MW 8.0 12.5

Power supply voltage, kV 6700 10000

Rated stator current, A 842 1245

Efficiency, % (not less than) 97.0 97.7

Power factor 0.85 0.85

Rated speed of rotor, rpm 8200 6500

Speed range, % 50-105

Type of cooling Air, open-loop

IC3A5 as per GOST 20459-87

Type of bearings Active electromagnetic suspension

Protection IР44

Weight, tons 16.0 20.0

Overall dimensions of motor unit, mm 4000х3000х3000 4000х4000х3000

NATURAL GAS BLOWER

Type of blower GE ВСL502 GE ВСL502

Volume throughput capacity, million nm3/day 16.0 22.0

Gas pressure after blower, MPa 5.49 5.49

Rated compression ratio 1.44 1.44

Polytrophic efficiency, % 86.8 87.0

Rated rotor speed, rpm 8200 6500

Type of bearings Active electromagnetic suspension

Sealing type Dry, gasdynamic

Weight, tons 17.5 20. 5

Overall dimensions of blower unit, mm 4000х4000х3000 4000х4000х3000

Page 80: Hydraulic Turbines

80

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

EGPU components Main parametersEGPU-8.0/8200-56/1.44-PCh-MP-

BK EGPU -12.5/6500-56/1.44- PCh-

MP-BK

FREQUENCY CONVERTER

Rated power, кВА 12470 13500

Output voltage, V 7200 7 000

Efficiency, % (not less than) 96.0 97.0

Protection IР31 IР42

Weight, tons 20.3 23.7

Overall dimensions of frequency converter unit, mm 9000х3500х3500 11000х4000х4000

Example of designation for EGPU -8.0/8200-56/1.44-PCh-MP-BK:

EGPU - 8.0 / 8200 - 56 / 1.44 - PCh - MP-BK

magnetic suspension – packaged modular

frequency converter

rated pressure ratio

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas compressor unit

12.4. Electrically driven 12.5 MW gas compressor units EGPU (non-controlled) Electrically driven gas compressor units EGPU-12.5/3000-76/1.23-R Lysva, non-controlled, with an electric motor of 12,500 kW, with the speed of 3,000 rpm and centrifugal blower 370-18-2. Designed for compression and transportation of natural gas through main gas pipelines.

Used for revamping the operated EGPU’s, where synchronous electric motor STD-12500-2 UKhL4 is replaced with synchronous electric motor SDG2-12500-2R UKhL3.1, and standard flow tube for 30 million nm3/ a day is installed in the existing pressurizer 370-18-2.

EGPU components Main parameters EGPU-12.5/3000-76/1.23-R Lysva

EGPU

Manufacturer - Elektrotyazhmash-Privod LLC

Rated power of drive, MW 12.5

Throughput capacity, million nm3/day 30

Rated speed of blower shaft, rpm 4800

EGPU weight, tons, (motor+blower) 87

Weight of heaviest unit, tons, not more than 47.8

ELECTRIC MOTOR

Manufacturer - Elektrotyazhmash-Privod LLC

Series SDG2-12500-2Р NFЗ 1

Type Synchronous

Rated efficiency, % 97.8

Rated speed of rotor, rpm 3000

Rated input voltage, V 107

Rated current, A 502

Cooling type Air

Specified life, hrs 100 000

Motor weight as supplied, tons 39.15

Overall dimensions of motor, mm 5800x3184x2730

Page 81: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

81

EGPU components Main parameters EGPU-12.5/3000-76/1.23-R Lysva

BLOWER

Manufacturer –

JSC Kompressor Komplex

Type 370-18-2

Rated power, consumed by blower, MW 8.05

Throughput capacity, million nm3/day 30.0

Polytrophic efficiency, % 84

Rated speed of rotor, rpm 4800

Pressure ratio 1.221

Max. discharge pressure, MPa 7.45

Weight, tons 47.8

START-UP FREQUENCY CONVERTER

Manufacturer –

OJSC Electrovipryamitel

Rated power, MW 13

Starting current, A 900

Rated voltage, V 10000

Mains frequency , Hz 50

Overall dimensions (LхBхH), mm 10640х2000х2780

Weight, tons 6.5

EXCITATION SYSTEM Manufacturer – Elektrotyazhmash-Privod LLC

Type VTTs-SD-Shch-NF4

Rated rectified current, A 320

Rated rectified voltage, V 230

Efficiency, % 95.3

EGPU - 12.5 / 3000 - 76 / 1.23 - Р Lysva

conditional designation of machine

supplied for revamping compressor workshops of compressor plants

rated pressure ratio

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas compressor unit

Page 82: Hydraulic Turbines

82

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

12.5. Electrically driven 12.5 MW gas compressor units EGPU (controlled) Electrically driven gas compressor units EGPU-12.5/5200-76/1.23-R Lysva, with a high-speed frequency-controlled motor with the power of 12,500 kW, with the speed of 5,200 rpm and centrifugal blower 370-18-2. Designed for compression and transportation of natural gas through main gas pipelines.

Used for revamping the operated EGPU’s, where synchronous electric motor STD-12500-2 UKhL4 is replaced with synchronous electric motor from TMEIC (Toshiba Mitsubishi-Electric Industrial Systems Corporation, Japan). Standard flow tube for 30 million nm3/day is installed in the existing blower 370-18-2; and the step-up gear is used as an intermediate bearer for the drive line, connecting the motor and blower.

EGPU components Main parameters EGPU-12.5/5200-76/1.23-R Lysva

EGPU Manufacturer – Elektrotyazhmash-

Privod LLC

Rated power of drive, MW 12.5

Throughput capacity, million nm3/day 30

Rated speed of blower shaft, rpm 5200

EGPU weight, tons, (motor + blower) 71.8

Weight of heaviest unit, tons, not more than 47.8

MOTORManufacturer –

TMEIC / Elektrotyazhmash-Privod LLC

Series TMEIC

Type Synchronous

Rated efficiency, % 96.5

Rated speed of rotor, rpm 5200

Rated input voltage, V 3600

Rated current, A 2085

Cooling type Air

Specified life, hrs 100000

Weight of motor as supplied, tons 24

Overall dimensions of motor, mm 5493.5x2800x3561

BlowerManufacturer –

JSC Kompressor Komplex

Type 370-18-2

Rated power, consumed by blower, MW 7.60

Throughput capacity, million nm3/day 30.0

Polytrophic efficiency, % 84

Rated speed of rotor, rpm 4800

Pressure ratio 1.226

Max. discharge pressure, MPa 6.1

Weight, tons 47.8

Frequency converterManufacturer –

TMEIC / Elektrotyazhmash-Privod LLC

Output power of converter, kVA 13500

Rated current, A 2100

Rated voltage, V 3600

Output current frequency, Hz 86.7

Efficiency, % ( not less than) 97

Overall dimensions (LxBxH), mm 8200x4000x2400

EGPU - 12.5 / 5200 - 76 / 1.23 - Р «Lysva»

conditional designation of machine

supplied for revamping compressor workshops of compressor plants

rated pressure ratio

rated operating pressure, atm

rotation speed, rpm

rated power, MW

electrically driven gas compressor unit

Page 83: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

83

12.6. Set of equipment for reconstructing electrically driven gas compressor unit of 12.5 MWSet of equipment KMCh EGPU-12.5/3000-76/1.44 (1.32)-R and electric motor with the power of 12,500 kW, rotational speed of 3,000 rpm and SPCH 370-23-3 pressure-tight changeable flow tube. Designed for compression and transportation of natural gas through main gas pipelines.

KMCh is used for revamping the operated EGPU’s, which electric motor STD-12500-2 UKhL4 with the open-loop ventilation is replaced with electric motor STD-12500-2R UKhL4 with the open-loop ventilation. Pressure-tight changeable flow tube (SPCh) is installed in the cylinder of centrifugal pressurizer 370-18-2.

EGPU components Main parameters KMCh EGPU-12,5/3000-76/1,44 (1,32)-R

EGPU Manufacturer –

Elektrotyazhmash-Privod LLC

Rated power of drive, MW 12.5

Rated speed of blower shaft, rpm 5000

Weight of heaviest unit, tons, not more than 28.9

MOTORManufacturer –

Elektrotyazhmash-Privod LLC

Series STD-12500-2Р NF4

Type synchronous

Rated efficiency, % 97.8

Rated speed of rotor, rpm 3000

Stator current, A 1368/820

Cooling type air

Specified life, hrs 200000

Weight of motor as supplied, tons 28.9

Overall dimensions, mm 5485x3225x2160

Type SPCh370-23-3

BLOWERManufacturer –

JSC Kompressor Komplex

Rated power, consumed by blower, MW 12.40

Pressure ratio 1.44 1.32

Polytrophic efficiency, % 84 82

Throughput capacity, million nm3/day 25 32.2

Rated speed of rotor, rpm 5000

Max. discharge pressure, MPa 7.45

Overall dimensions, mm 1720x3621

START-UP FREQUENCY CONVERTER

Manufacturer – OJSC Electrovipryamitel

Rated power, MW 13

Starting current, A 900

Rated voltage, V 10000

Mains frequency, Hz 50

Overall dimensions (LxBxH), mm 10640x2000x2780

Weight, tons 6.5

KMCh EGPU - 12.5 / 3000 - 76 / 1.44 (1.32) - Р

supplied for revamping compressor workshops of compressor plants

rated pressure ratio (compression ratio)

rated operating pressure, atm

rated speed of motor, rpm

rated power, MW

electrically driven gas compressor unit

set of equipment

Page 84: Hydraulic Turbines

84

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

12.7. High-speed variable-frequency electric drives EPRV

High-speed variable-frequency electric drives are designed for direct-driven high-speed machines, including centrifugal blowers used as a part of electrically driven gas compressor machines.

Electric drives comprise a high speed frequency regulated electric motor and a rotor on the magnetic suspension and GST inverter (frequency converter) with the required components. If necessary, the electric drive can be equipped with automatic control system upon the customer’s request.

Embodiment IM 1001

Cooling system air, open-loop

Cooling method IC31

Protection class motor – IP23; frequency converter – IP20

Rated operating conditions S1

Noise level not more than 85 dBA

They are fabricated and supplied under TMEIC license.

Delivery set includes: the motor, HV frequency converter, automatic control system, spare parts, and operation documents.

Product type Power, kW Rotation speed, rpm Voltage before converter, kVRange of rotation speed

variation, % of rated

EPRV-4000-8200 NF4 4000 8200 3.0 50-105

EPRV-6300-8200 NF4 6300 8200 3.3 50-105

EPRV-8000-8200 NF4 8000 8200 3.9 50-105

EPRV - XXXX - 8200 NF 4

location category

climatic version

motor speed, rpm

capacity, kW

high-speed variable-frequency electric drive

Page 85: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

85

13. TRANSfORMING EQUIPMENT

13.1. High voltage frequency converters HV-VfD

High voltage frequency converters are designed to control the rotation speed and rotation moment in synchronous and asynchronous AC electrical motors.

frequency converters HV-VfD can be used to adjust frequency in electric drives of water and oil pumps (including the submersible pumps), ventilators, compressors (including piston compressors), high-speed electrically driven gas pumping machines, exhausters, blowers, extruders, ventilators etc. used in systems of powerful compressors and turbogenerators smooth start at oil, gas, metallurgical, paper-making facilities and the energy plants, on marine vessels, open sea rigs, coast line rigs and for other applications.

Rated voltage, V 3000*, 3300*, 6000, 6600*, 10000, 11000* (technical parameters of HV-VFD with the voltage parameters given are provided upon request)

Output frequency up to 200 Hzfrequency regulation precision ± 0,5%125% Overrun regimen functioning 1 minIncoming power factor over 95%Efficiency over 97%Cooling forced air coolingControl system sensor-free vector control + PWM (pulse width modulation)Protection level IP20Atmosphere type II (manufacturing facilities atmosphere)

Technical parameters of HV-VFD-xxx-6 NF4

Motor capacity, kW 315 400 500 630 710 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000... 14000

Rated voltage, V 6000

Rated output current, A 40 53 61 70 93 105 120 160 215 250 325 375 430 600 800 1000... 1700

Size: HxWxD, mm 3300х2643х1000 4200x2643x1000 Upon request

Weight, kg 2955 3409 Upon request

Technical parameters of HV-VFD-xxx-10 NF4

Motor capacity, kW 315 400 500 630 800 1000 1250 1600 2000 2500 2800 3150 4000 5000 6300 8000… 31500

Rated voltage, V 10000

Rated output current, А 40 40 40 53 61 70 93 105 120 160 215 250 325 375 430 600... 2400

Size: HxWxD, mm 3,300x2,643x1,000 4,200x2,643x1,000 Upon request

Weight, kg 2955 3409 Upon request

Note: technical parameters are agreed during the project planning

VFD - HV - XXX - YYY NF 4

category of location

climatic version

rated voltage, V

rated capacity, kW

high voltage

frequency converter

Page 86: Hydraulic Turbines

86

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

13.2. High voltage soft starters SSM-HV

High voltage soft starters are designed for starting synchronous and asynchronous motors under smooth voltage rise and motor current limitation at a set level.

High voltage soft starters SSM-HV can be used for soft starting of water and oil pumps (including the submersible pumps), fans, compressors (including piston compressors), exhausters, blowers, extruders, starting of low power sources (diesel generators, long power lines, etc.), etc. used at oil, gas, metallurgical, paper-making facilities and the energy plants, on marine vessels, open sea rigs, coast line rigs and other applications.

SSM-HV for 8,000-31,500 kW motors ensures the motor start by underfrequency relay.

Rated voltage, V 3000*, 3300*, 6000, 6600*, 10000, 11000*, 13800*, 15000* (* technical parameters of SSM-HV and voltage parameters are provided upon request)

frequency, Hz 50/60 ± 2

Current range, A 60-2,500 in long-term regimen

Protection level IP21

Atmosphere type II

SSM-HV can be used as a system component or separately, with different options, including linear and/or shunt contactors, power switcher, fuses, motor protection relay, control systems, etc. Complex multi-motor systems with soft start can be based on SSM-HV.

Technical parameters of SSM-HV-xxx-6 NF4

Motor capacity, kW 315 400 500 630 710 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500

Rated voltage, V 6000

Rated output current, A 200 400 600 Upon request

Size: HxWxD, mm 915x915x2315 915x915x2315 1778x915x 2315 Upon request

Weight, kg 554 554 951 Upon request

Technical parameters of SSM-HV-xxx-10 NF4

Motor capacity, kW 500 630 800 1000 1250 1600 2000 2500 2800 3150 4000 5000 6300 8000 10000 12500 20000 31500

Rated voltage, V 10000

Rated output current, A 200 400 Upon request

Size: HxWxD, mm 2600x2300x1340 Upon request

Weight, kg 2133 2133 Upon request

Note: technical parameters are agreed during the project planning.

SSM - HV - XXX - YYY NF 4category of location

climatic version

rated voltage, V

rated capacity, kW

high voltage

soft starter

Page 87: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

87

14. TRACTION ELECTRICAL EQUIPMENT

14.1. Traction generators for main-line freight gas turbine locomotives

14.1.1. Traction machine ATG-7370/600-6000 N2

Traction machine ATG-7370/600-6000 N2 is designed for feeding traction motors through a rectifier unit of traction commutator motors and is included in the structure of the GT1 gas turbine locomotive, designed for freight trains in the workshops equipped with a gas supply system

Machine structure:

Synchronous traction generator GST 7370-6000-2U2

Synchronous auxiliary generator GSV 600-6000-2U2

Transmission “traction generator- auxiliary generator”

Embodiment IM 1001

Cooling method ICA37

Excitation independent, by contact rings

Protection class IP 54 – for generator, IP 23 – for contact rings assembly

Generator current type alternating, three-phase

Insulation class stator winding - F, rotor winding - Н, contact rings - F

Rated operating conditions S1

Corresponds to GOST 2582 and is manufactured according to technical requirements ТU3381-111-05810695-2006.

Delivery set includes: traction machine, spare parts, and operation documents.

Parameters

Values

GST 7370-6000-2N2GSV 600-6000-2N2

Intermittent operation Continuous operation

Capacity, kW 7370 7370 600

Max. line voltage, V 1200 1200 400

Current, Аat voltage

2x2560925

2x2390990

2x720

Power factor соs ϕ, power units . 0.9 0.6

Frequency, Hz 100

Rotation speed, rpm 6000

Efficiency, % 96.5 91.0

Max. rectified voltage value, V 1500 -

Excitation current in continuous operation (max.), A 300 250

GST - 7370 - 6000 - 2 N 2location category

climatic version

number of poles

rotation speed, rpm

capacity, kW

synchronous traction generator

GSV - 600 - 6000 - 2 N 2location category

climatic version

number of poles

rotation speed, rpm

capacity, kW

synchronous auxiliary generator

Page 88: Hydraulic Turbines

88

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.1.2. Synchronous traction generators for main-line freight gas turbine locomotive GT1h

Synchronous traction generators GST 7500/8150-5400-2N2 is designed for feeding traction motors through a rectifier unit of traction commutator motors and is included in the structure of the power train of the GT1h gas turbine locomotive, designed for freight trains equipped with a gas supply system.

Embodiment IM 1001

Cooling method ICA37

Excitation independent, by contact rings

Protection class IP 54 – for generator, IP 23 – for contact rings assembly

Generator current type alternating, three-phase

Insulation class stator winding - F, rotor winding - Н, contact rings – not less than F

Rated operating conditions S1

Corresponds to GOST 2582 and is manufactured according to technical requirements IBZhK.528565.003 TU

Delivery set includes: the generator, spare parts, and operation documents.

Parameters Values

Continuous operation Intermittent operation

Capacity, kW 7500 8150 8150

Max. line voltage, V 623

Max. short-term phase current for 5 min., A 6500

Phase current, A, at line voltage, V2x5550

4162x4100

6232x5550

459

Power factor соs ϕ, power units 0,92

Frequency, Hz 90

Speed, s-1 (rpm) 90 (5400)

Efficiency, % 97,0

Excitation current in continuous operation (max.), A 290

Weight of generator, kg 13120

GST - 7500 / 8150 - 5400 / 2 - N 2

location category

climatic version

number of poles

rotation speed, rpm

generator power, for intermittent operation, kW

generator power, for continuous operation, kW

synchronous traction generator

Page 89: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

89

14.2. GST traction alternators

The GST synchronous salient alternators are used to convert the mechanical energy of diesel motors of locomotives into electric energy, and to supply power to direct current electric traction motors through a rectifying module. The alternators are mounted to the diesel locomotive’s haul.

Embodiment IM 1305 - GST 1050-1000 NF2 IM 1309 – other units

Cooling method IC01 (self-ventilation) - GST 1050-1000 NFL2IC37 (independent ventilation) – other unitscooling air is taked from outside through air filters

Excitation GST 1400-1500 N2 (NFL2) - Independent, through clip ringsother units - Independent, from single-phase exciter type VSTgenerator GST 1050-1000 NF2 has an ancillary stator coil for power supply of auxiliary and excitation systems’ electric drives of diesel-locomotive shunters

Protection level IР21

Insulation class GST 1050-1000 NF2: stator coil - H, rotor coil - F, slip rings - ВGST 1400-1000 N2 (NF2): stator and rotor coil - F, slip rings - В GST 1400-1500 N2 (NF2): stator and rotor - Н, slip rings – min. F GST 2800-1000 N2: stator and rotor coil – F, slip rings - В

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with:

GST 1050-1000 NF2 - TU3381 042 05810695 2004;

GST 1400-1000 N2 (NF2) - TU16 05810695 023 95;

GST 1400-1500 N2 (NF2) - TU3381 135 05810695 2009;

GST 2800-1000 N2 - TU16 05810695 011 93.

The embodiment of the generators is protected by utility model patent No. 32268.

Certificates of conformity:

GST 2800-1000 N2 - No. SSFJT RU. CT03.B.08109;

GST 1400-1000 N2 (NF2) - No. SSFJT RU. CT03.B.08110.

GST 1400-1500 N2 (NF2) - No. SSFJT RU. CT03.A.09292.

Delivery set includes: an alternator, spare parts, and operation documents.

Type of alternator Active power, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

GST 1050-1000 NF2 1050 1000/505 1000 94.0/94.5 4500

GST 1400-1000 N2, NF2 1400 280/175 1000 95.8/95.5 5130

GST 1400-1500 NF2 1400 280/175 1500 95.8/95.0 4000

GST 2800-1000 N2 2800 580/360 1000 95.9/95.0 6000

GST XXXX - YYYY N (NF) 2category of location

climatic version

rotation speed, rpm

capacity, kW

synchronous traction alternator

Page 90: Hydraulic Turbines

90

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.3. GPT 840-750N2 direct current generator

The GPT 840-750N2 direct current generator is designed to supply power to traction motors and is a component of TEM-18 locomotives.

Embodiment IM 9809

Cooling method IC01

Excitation independent

Protection level IP00

Insulation class F

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with TU 3381-091-05810695-2004.

Delivery set includes: generator, spare parts, and operation documents.

Type of generator Capacity, kW Rated voltage, V Current, A Rotation speed, rpmEfficiency

%Weight, kg

GPT 840-750 N2 840 636/870 1320/966 750 94.3 4850

GPT - 840 - 750 N 2category of location

climatic version

rotation speed, rpm

capacity, kW

direct current motor generator

Page 91: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

91

14.3. ASTM 2800/600-1000 N2 synchronous traction unit

ASTM 2800/600-1000 N2 synchronous traction unit is designed to supply power to traction motors through the rectifying module. It also supplies power to excitation systems for auxiliary systems of locomotives and power consumers, and to the electric circuits of passenger train cars.

Unit structure traction and auxiliary synchronous generators combined in a single casing

Embodiment IM 1305 or IM 1309

Cooling method IC37

Excitation independent

Protection level IP21

Insulation class F, slip rings – В

Climatic version N

Category of location 2

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with TU 16-05810695-040-2004.

Delivery set includes: unit, spare parts, and operation documents.

Description of parameter Traction generator

Auxiliary generator

Power supply coil Auxiliary power supply coil

Rated capacity, kW

with power supplying 2470 600 171

w/o power supplying 2800 - 260

Rated value of linear voltage, V

with power supplying 580/465 2х1200 400

w/o power supplying 580/366 - 400

Rated value of current (phase), A

with power supplying 2х1300/2х1650 150 405

w/o power supplying 2х1520/2х2400 - 565

Rated Rotation speed, rpm 1000 1000

Efficiency, % 95.5/95.0 91.0

Weight, kg 7350

ASTM - 2800 / 600 - 1000 N 2

category of location

climatic version

rotation speed, rpm

capacity of auxiliary generator, kW

capacity of traction generator, kW

modernized synchronous traction unit

Page 92: Hydraulic Turbines

92

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.4. ASTG 2800/400-1000 N2 and ASTG2 2800/400-1000 N2 synchronous traction units

ASTG 2800/400-1000 N2 synchronous traction unit is designed for diesel units of main line cargo locomotives 2TE25K with commutator motors EDU 133Tz, and as an upgrade for previously manufactured locomotives

ASTG2-2800/400-1000 N2 synchronous traction unit is designed to feed asynchronous traction motors through back-to-back module, to feed self-excitation systems and power consumers of supporting systems and cargo locomotives equipped with asynchronous motor drive (2TE25 and TE25A locomotives).

Unit structure traction and auxiliary synchronous generators combined in a single casing

Embodiment IM 1309

Cooling method IC37

Excitation independent

Protection level IP21

Insulation class Н – stator coils of ASTG2 unit F – stator coils of ASTG, and rotors and slip rings of ASTG and ASTG2 units

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with:ASTG 2800/400-1000 N2 - TU 16-05810695-040-2004, ASTG2-2800/400-1000 N2 - TU 3381-112-05810695-2008. Conformity certificate:ASTG2 2800/400-1000 N2 - No. SSFJT RU. CT03.B.07571.

Delivery set includes: unit, spare parts, and operational documents.

Type of generator Generator Capacity, kW Voltage, VRotation speed,

rpmEfficiency, % Weight, kg

ASTG 2800/400-1000 N2traction 2800 580/366 1000 95.5/95.0

7350auxiliary 400 400 1000 91.0

ASTG2-2800/400-1000 N2traction 2800 1450 1000 95.5

7350auxiliary 400 400 1000 91.0

ASTG 2 - 2800 / 400 - 1000 N 2

category of location

climatic version

rotation speed, rpm

capacity of the auxiliary generator, kW

capacity of traction generator, kW

design number

synchronous traction unit

Page 93: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

93

14.5. VST exciters

The VST synchronous traction exciters are designed to excite traction generators of locomotives. The exciter is an inverted one-phase synchronous alternating current machine with salient poles.

Embodiment IM 1103

Cooling method IC01

Excitation independent, up to 110 V

Protection level IP21

Insulation class F – Armature, Poles, Slip rings

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with ТU 16-05810695-012-93.

Conformity certificate № SSFJT RU. CT03.B.00292D

Delivery set includes: exciter, spare parts, and operational documents.

Type of exciter Active power, kW Voltage, V Rotation speed, rpm Efficiency, % Weight, kg

VST 16-3300 NF2 16 220/230 1700/3300 72,0 355

VST 26-3300 N2 (NF2) 26 215/287 2470/3300 76,0 360

VST XX - 3300 N (NF) 2

category of location

climatic version

rotation speed, rpm

active capacity, kW

synchronous traction exciter

Page 94: Hydraulic Turbines

94

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.6. EDU-133 traction motors

The EDU-133 Nf1 traction four-pole direct current motors are designed to drive the wheel pairs of locomotives.

Embodiment MOS rollers and frame suspension. Motors are equipped with plug-in roller bearings. Design of seals for armature bearings prevents leaking of grease from bearings and entry of dust and moisture.

Cooling method IC17

Excitation series

Protection level IPX5

Insulation class Н – armature F – poles

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with TU16 05810695 035 97. Conformity certificate:EDU-133TR - No. SSFJT RU. CT03.B.08073.

Delivery set includes: motors (6 pcs), spare parts, and operation documents

Type of motor Active power, kW

Rated voltage , V Rated current, A

Rotation speed, rpm Efficiency, %

Weight, kg

EDU-133C NF1414 506/780 890/577 600/2320 92.0 3350

EDU-133ТР-C NF1

EDU-133Р NF1414 506/780 890/577 600/2320 92.0 2950

EDU-133ТР-Р NF1

EDU-133P NF1414 506/780 890/577 600/2320 92.0 3100

EDU-133ТР-P NF1

EDU-133К NF1414 506/780 890/577 600/2320 92.0 3100

EDU-133ТР-К NF1

EDU - 133 ТР - C(R, K, P) NF 1

category of location

climatic version

C - circulation type of lubrication system; P - lubricating pad system;K - MOS roller;R - frame suspension

adjusting interphase connecting rod

design number

universal electric motor

Page 95: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

95

14.7. EDU-136 traction motors

EDU-136R NF1 DC traction motor with laminated frame is designed to drive wheel pair of TEP 70 main- line diesel locomotives and other motorized tipcarts.

Taking into account its overall and linkage dimensions and performance characteristics the motor is replaceable by EDU 133 R motor.

Ventilation of motors is of independent forced type. Method of cooling is ICA 17.

Type of motor Active power, kW Rated voltage , V Rated current, A Rotation speed, rpm Efficiency, % Weight, kg

EDU-136Р NF1 414 506/780 890/577 600/2320 92.0 2650

EDU 136 R NF 1

climatic version

climatic version

frame suspension

design number

universal electric motor

Page 96: Hydraulic Turbines

96

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.8. DAT asynchronous traction motors

DAT-350-6 Nf1, DAT-470-8 Nf1 asynchronous traction motors with short-circuit rotor to drive wheels pairs of main line six-axle cargo locomotives of series 2TE25T, TE25T with capacity of 2,500 kW in the section and locomotives of series 2TE35, TE35 with capacity of 3,500 kW in the section (only DAT-470-8 NF1) with traction AC power transmission. Motors are equipped with elements for thrust suspension with the use of motor thrust bearings.

Embodiment IM 9403 design of motor bearings’ seals prevents leaking of grease from bearing blocks and entry of dust and moisture from both inside and outside.

Cooling method IC17

Power supply from synchronous traction generator through static frequency converter based on voltage invertor on IGBT transistors with maximum pulse-width modulation of 1.5 kHz

Protection level IPX5

Insulation class H

Rated operating conditions S1

Comply with GOST 2582 and Manufactured in compliance with TU3355 114 05810695 2006.

Conformity certificate for DAT 350 6 NF1 - No. SSFJT RU. CT 03.A.06119.

Delivery set includes: motor, rotation velocity sensors and temperature sensors, spare parts, and operation documents.

Type of motor Capacity, kW Voltage, V Phase current, А Rotation speed, rpm Efficiency, % Weight, kg

DAT-350-6 NF1 350 800/1410 470/306 2300 92.3 2350

DAT-470-8 NF1 470 909/1410 417 2380 92.3 2300

DAT - XXX - Y NF 1

category of location

climatic version

number of poles

capacity, kW

asynchronous traction motor

Page 97: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

97

14.9. 4PNJ-200MA direct current motors

4PNJ-200MA direct current motors are designed to drive the blowing of braking resistors in locomotives.

Embodiment IM 2003

Cooling method IC01

Excitation series

Protection level IP23

Insulation class H

Climatic version NF

Category of location 2

Rated operating conditions S1

Comply with GOST 2582 81 and Manufactured in compliance with TU16 05810695 045 99.

Declaration of conformity No. SSFJT RU. CT03.B.0064D.

Delivery set includes: motor, spare parts, and operation documents.

Type of motor Rated capacity , kW Rated voltage , V Rated current, А Rotation speed, rpm Efficiency, % Weight, kg

4PNJ-200MA 60 340 197 3000 89.4 350

4 PN J 200 М А

modification

length of the core stamping

dimension

for railway transport

protected with self-ventilation

series designation

Page 98: Hydraulic Turbines

98

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.10. DTK-800M N1 Direct-current traction motor

Six-pole direct-current traction motor is designed to drive sets of wheels of DC electric passenger locomotives EP2K with overhead system rated voltage of 3 kW. Motor is manufactured with plug-in type roller bearings. Seal design of armature bearings prevents oil bleeding from bearings and entry of dust and moisture in bearings both from inside and outside.

Embodiment frame suspension

Cooling method IC17

Excitation series

Protection level IPX5

Insulation class H

Comply with GOST 2582 and Manufactured in compliance with TU3355 122 05810695 2007.

Delivery set includes: motors (6 pcs), spare parts, and operation documents

Description of parameter DTK-800М N1

Rated operating conditions S2 (60 min) S1

Rated capacity, kW 800 720

Rated voltage, V 1500 (3000/2)

Rated armature current, А 565 510

Rated Rotation speed, rpm 945 980

Efficiency, % 94.2 94.2

Maximum rotation speed, rpm 1720

Weight, kg 3850

DTK - 800 М N 1

category of location

climatic version

modernized

hourly capacity of traction motor, kW

direct-current traction motor

Page 99: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

99

14.11. DTK-810M Nf1 direct-current traction motor

Six pole direct-current traction motor is designed to drive sets of wheels of DC main line cargo locomotives 2ES6 with overhead system rated voltage of 3 kW. Motor is manufacture with plug-in type roller bearings. Seal design of armature bearings prevents oil bleeding from bearings and entry of dust and moisture in bearings both from inside and outside.

Embodiment thrust suspension

Cooling method IC17

Excitation independent

Protection level IPX5

Insulation class H

Comply with GOST 2582 and Manufactured in compliance with TU 3355-115-59162910-2008.

Delivery set includes: motor (8 pcs), spare parts, and operation documents.

Description of parameter DTK-810 N1

Rated operating conditions S2 (60 min) S1

Rated capacity, kW 810 745

Rated voltage, V 1500 (3000/2)

Rated current, А 575 525

Rated Rotation speed, rpm 750 770

Efficiency, % 94.25 94.5

Maximum rotation speed, rpm 1800

Weight, kg 4800

DTK - 810 N 1

category of location

climatic version

hourly capacity of the traction motor, kW

rotational traction motor

Page 100: Hydraulic Turbines

100

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.12. DPT direct current motors

DPT direct current motors are designed to operate the compressor units of locomotives

Embodiment IM 1003

Cooling method IC01

Protection level IP22

Insulation class H

Comply with GOST 2582 and Manufactured in compliance with TU16 05810695 046 98.

Delivery set includes: motor, spare parts, and operation documents.

Declaration of conformity: No. SSFJT RU. CT03.B.00663D

Type of motor Excitation Capacity, kW Voltage, V Rated current, А Rotation speed, rpm Weight, kg

DPT-25 NF2 mixed 25 110 276 1000 550

DPT-25 NF2 series 25 110 276 1000 550

DPT-37 NF2 mixed 37 110 400 1450 550

DPT - XX NF 2

category of location

climatic version

capacity, kW

direct current motor

Page 101: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

101

14.13. 5SG, 6SG, 7SG starter-generators

5SG, 6SG, 7SG starter-generators are designed to start-up diesel generators and to operate as an auxiliary generator of the locomotive.

Embodiment IM 1003

Cooling method IC01

Excitation generator mode - independentstarter mode - successive

Protection level IP21

Insulation class H

Rated operating conditions starter (breakaway mode and motoring mode) - S2 (10 sec)generator - S6 and S1

Comply with GOST 2582 and Manufactured in compliance with:

5SG N2 (UF2, Т2) - TU 16 05810695 041 98;

6SG N2 - IBJK.527612.019 TU;

7SG N2 - TU 3355 109 05810695 2005.

Declaration of conformity No. SSFJT RU. CTOZ.B.00665D for 5SG.

Declaration of conformity No. SSFJT RU.CTOZ.B.00156D for 6SG.

Delivery set includes: starter-generator, spare parts, and operation documents.

Type of motor Operating conditions Capacity, kWArmature voltage, V

Maximum load duration, %

Current, A Rotation speed, rpm

5SG NF2 (N2, Т2)S1 50 110 100 455 1050/3333

S6 62/32 110 50 564/291 1050/3333

6SG N2S1 60 110 100 546 1050/3300

S6 70/40 110 50 636/364 1050/3300

7SG N2 S1 55 110 100 500 800/2300

5 (6, 7) SG N (NF, Т) 2

category of location

climatic version

starter-generator

design number

Page 102: Hydraulic Turbines

102

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.14. DAVT-280-15-4/6/12 N2 (N5) asynchronous traction motor

DAVT-280-15 asynchronous explosion proof three-speed traction motor with a short-circuit rotor is designed to drive mine self-propelled cars with load-carrying capacity of 15 tons, working in gaseous-and- dusty mines where potash and shale are extracted.

Embodiment IM 2001with grease-lubricated rolling bearings. Bearing blocks have devices for grease removal and refilling without motor disassembly

Cooling method IC40

Protection level IP54

Insulation class H

Rated operating conditions S4

Comply with GOST R 52776-2007 and Manufactured in compliance with TU 16-05810695-062-2000.

Delivery set includes: motor, and operation documents.

Type of motorNumber of

polesCapacity, kW Voltage, V

Rotation speed, rpm

Power factor Efficiency, % Weight, kg

DAVT-280-15-4 N2 (N5) 4 22 660 1500 0.967 79.9 930

DAVT-280-15-6 N2 (N5) 6 46 660 1000 0.921 82.1 930

DAVT-280-15-12 N2 (N5) 12 23 660 500 0.727 83.6 930

DAVT - 280 - 15 - X N 2 (5)

category of location

climatic version

number of poles

car load capacity, tons

height of rotation axis, mm

asynchronous explosion proof traction motor

Page 103: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

103

14.15. DATE-170 N2 and DAT-170 N2 asynchronous traction motors

DATE-170-4N2 asynchronous, squirrel-cage traction motor is designed for driving mounted wheels of the lead and other subway cars types 81-720, 81-721, 81-740, 81-741.

DAT-170-4N2 asynchronous, squirrel-cage traction motor is designed for driving mounted wheels of the lead and other subway cars types 81-760/761.

Embodiment M 9703

Power supply from frequency converter and voltage inverter with formation of voltage curve on the principle of pulse-width modulation at voltage rise rate of 1 kV/μs

Cooling method IC01

Protection level motor - IP20 input equipment - IP54

Insulation class H

Rated operating conditions S2 (60 min)

Comply with GOST R 52776-2007, GOST 2582 and Manufactured in compliance with TU3355 077 05810695 2003.

Delivery set includes: motor, and operation documents.

Type of motor Capacity, kW Voltage, VCurrent frequency

of the stator, HzRotation speed, rpm

rated/maxEfficiency % Weight, kg

DATE-170-4 N2 170 530 43 1290/3600 92.0 805

DAT-170-4 N2 170 530 43 1290/3600 92.0 780

DATE - 170 - 4 N 2

category of location

climatic version

number of poles

capacity, kW

asynchronous traction motor for electric locomotives

Page 104: Hydraulic Turbines

104

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.16. AMVR-37 asynchronous motor for motor-fan

AMVR-37 asynchronous three phase current motor with an external rotor is designed to operate axial motor-fans cooling water and oil in locomotives’ diesel motors.

Embodiment vertical

Insulation class H

Rated operating conditions S3 (50%)

Comply with GOST 2582 and Manufactured in compliance with TU 3324-102-05810695-2007.

Delivery set includes: motor, and operation documents

Type of motor Rated capacity, kW Rated voltage, V Rotation speed, rpm Efficiency, % Weight, kg

AMVR-37-U3 37 400 1500 92 144

AMVR - 37 - U 3

category of location

climatic version

capacity, kW

asynchronous integrated for motor-fan with controlled Rotation speed

Page 105: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

105

14.17. Kicking coils

14.17.1. DSf-1L N2 power line filter kicking coil for subway cars

DSf-1L N2 power line filter kicking coil is designed to operate as a part of an asynchronous drive to decrease pulsation of current consumed from power mains and for installation on lead and other subway cars.

Cooling method IC40

Protection level kicking coil - IP00 terminal box - IP54

Insulation class H

Climatic version N

Category of location 2

Comply with GOST 9219 and Manufactured in compliance with TU3459 093 05810695 2005.

Delivery set includes: motor, and operation documents.

Description of parameter Value

Rated voltage, V 750

Rated current, A 470

Maximum current, A 1100

Induction under current 1000 A, mH 8

Weight, not exceeding, kg 1270

Overall dimensions:

length, mm 1140

width, mm 880

height, mm 460

14.17.2. DS-2 smoothing kicking coil

DS-2 Nf smoothing kicking coil is designed for reduction of current pulsation In the circuit of a one phase rectifier energizing auxiliary power consumers of the locomotive.

Cooling method IC40 (self-ventilated)

Protection level IP00

Insulation class F

Climatic version N

Category of location 3

Rated operating conditions S1

Delivery set includes: kicking coil, data sheet.

Description of parameter Value

Rated voltage, V 150

Rated current, A 100

Mains frequency, Hz 60...200

Induction under current 30 A, mH 15

Weight, not exceeding, kg 85

Overall dimensions:

length, mm 410

width, mm 255

height, mm 350

Page 106: Hydraulic Turbines

106

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.18. Set of electric equipment and automation for locomotives14.18.1. PK-1000L - series electropneumatic contactors

PK-1000L - series electropneumatic contactors are designed to perform switchover operations in power circuits of direct current traction electric motors on locomotives.

Protection level IP00

Climatic version N, NF, Т

Category of location 3

Manufactured in compliance with GOST 9219 and TU 3457-050-05810695-2004.

Delivery set includes: contactor; spare parts, and operation documents.

Description of parameterType of contactor

PК-1146L PК-1148L PК-1218L PК-1416L PК-1616L

Contacts of main circuit

Rated voltage of insulation, V 1000 1000 1000 1000 1000

Rated cut-off current, A 1000 1000 500 500 500

Number of poles 1 1 2 4 6

Contacts of auxiliary circuit

Rated voltage, V 1000 1000 1000 1000 1000

Rated current, A 6.3 6.3 6.3 6.3 6.3

Contacts embodiment 2c 1o 1c 2o 1c 2o 2c 1o 2c 1o

Weight, kg 18 18 22 27 32

Note: c - closing contact, o - opening contact

PК - 1 1 (2, 4, 6) 1 (4) 6 (8) L

manufacturer's index

embodiment of auxiliary contacts

symbolic notation based on rated current value

number of switched circuits

notation of series

pneumatic contactor

Page 107: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

107

14.18.2. PPK-8000L-series electropneumatic switches

PPK-8000L-series electropneumatic switches are designed to switch over de-energized electric circuits of direct current traction motors, and are used as reversing gear or braking switches.

Protection level IP00

Climatic version N, NF, Т

Category of location 3

Comply with GOST 9219 and Manufactured in compliance with TU3457 053 05810695 2005.

Delivery set includes: switch, spare parts, and operation documents.

Description of parameterType of switch

PPK-8023L PPK-8042L PPK-8064L PPK-8122L

Rated voltage of insulation, V 900 900 900 900

Contacts of main circuit

Rated current, A 1000 1000 1000 900

Contacts of auxiliary circuit

Rated voltage, V 75 110 110 110

Rated current, A 2 2 2 2

Pneumatic drive

Rated voltage of gate coil, V 75 110 110 110

Rated value of air pressure, MPa 0.5 0.5 0.5 0.5

PPK - 8 02 (04, 06, 12) 2 (3, 4) L

manufacturer's index

embodiment

number of switched circuits

notation of series

pneumatic cam-operated switch

Page 108: Hydraulic Turbines

108

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

14.19. DPT-196M N2 traction motor

DPT-196M N2 direct current traction motor is designed to convert the generator’s electric power into mechanical energy for movement of tractor DET 320 and its modifications.

Embodiment IM 1109

Cooling method IC37 (independent ventilation)

Protection level IP20

Rated operating conditions S1

Comply with GOST R 52776-2007 and Manufactured in compliance with TU 3355-094-05810695-2004.

Delivery set includes: motor, spare parts, and operation documents.

Type of motor Capacity, kW Rated voltage , V Current, ARotation speed, rpm,

rated/max.Efficiency % Weight, kg

DPT-196М N2 196 300 710 420/2250 90 2550

DPT - 196 М N 2

category of location

climatic version

modification

capacity, kW

direct current motor

14.20. Privod-TRL1 set of traction electric equipment for trolleybuses with reostatic-contactor control systems

Privod-TRL1 set of traction electric equipment for trolleybus Trolza 5275 05 is used as a traction electric drive on trolleybuses with reostatic-contactor control systems.

Comply with GOST 9219.

Delivery set includes: interference-suppressing choke RP-1 N2, switch box PK-1 N3, resistor bank BR-1 N2, resistor bank BR 2 N2,

trolleybus driver controller KVT-1 N2, contactor reverse controller RK-1 N2, cam-shaft controller KG-1 N3, and operation documents.

Description of parameter Value

Rated voltage of power circuit, V 550

Rated voltage of control circuit, V 24

Average current in start-up mode, not exceeding, A 350

Weight of set, not exceeding, kg 1270

Page 109: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

109

14.21. DPT-110 N2 traction motor for trolleybus

DPT-110 N2 direct current traction motor is designed for trolleybuses with relay-contactor control systems.

Embodiment IM 1103

Cooling method IC01

Excitation mixed

Protection level at air inlet - IP33 at air outlet - IP20

Insulation class H

Rated operating conditions S2 (60 min)

Comply with GOST R 52776-2007 and Manufactured in compliance with TU 3355-099-05810695-2004.

Delivery set includes: motor, spare parts, and operation documents.

Type of motor Capacity, kW Rated voltage , V Current, АRotation speed, rpm,

rated/maxEfficiency % Weight, kg

DPT-110 N2 110 550 220 1430/3900 90.9 700

DPT - 110 N 2

category of location

climatic version

capacity, kW

DC traction motor

Page 110: Hydraulic Turbines

110

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

15. GOST CONVENTIONS

15.1. Embodiment (in compliance with GOST 2479) Designation Description

IM 1001 Machines with feet, two bearing shields and one cylindrical shaft end

IM 3731 Machines without feet and two bearing shields, with a flange inaccessible from the back side, with one cylindrical shaft end

IM 4011Machines without feet and two bearing shields; free cylindrical shaft end is directed downwards; flange on the stand is accessible from the back side, located on the side of the free shaft end

IM 5710 Machines without bearing shields, with a stand on raised feet and base plates without shaft end

IM 7011 Machines with pillar type bearing, with feet and base plate with one cylindrical shaft end

IM 7111 Machines with one pillar type bearing on raised feet and base plates with one flanged shaft end

IM 7211 Machines with two pillar type bearings on a common base plate, with one cylindrical shaft end

IM 7311 Machines with pillar type bearings on raised feet and base plate with one cylindrical shaft end

IM 7321 Machines with pillar type bearings on separate plates with one cylindrical shaft end

IM 8721 Machines with vertical shaft, with thrust plate over rotor, with flywheel, with one cylindrical shaft end

IМ 9633 Machines of special embodiment with two bearing shields, on feet in the horizontal plane, with one cone shaft end

15.2. Cooling method (in compliance with GOST 20459)Designation Description

IC01 Protected machine with self-ventilation; the fan is located on the machine's shaft

IC31 Cooling by fans installed in the rotor shaft, inlet and outlet channels (louvers), or air treatment units installed on the machine casing

IC40 Enclosed machine with self-cooling without external fan

IC0141 Enclosed machine with finned or smooth stand, ventilated by external fan installed ion the machine’s shaft

IC0151 Air-cooling of machines by self-ventilation using a cooler integrated in the machine and using ambient air

IC0161 Air-cooling of machines by self-ventilation using a cooler installed on the machine and using ambient air

ICW37A31 Air-cooling of machines by self-ventilation using a cooler installed on the machine and using water

ICW37A71Enclosed machine with air cooling and integrated water cooler; water in the cooler is circulated by a separate pump independent of the cooled machine or from water system

ICW37A81 Enclosed machine with air cooling and built-on water cooler; water in the cooler is circulated by a separate pump or from water system

15.3. Protection level (in compliance with GOST 14254)Designation Description

IP10 Protected against foreign solids with the diameter ≥ 50 mm; no water ingress protection

IP20 Protected against foreign solids with the diameter ≥ 12,5 mm; no water ingress protection

1Р21 Protected against foreign solids with the diameter ≥ 12,5 mm and against vertically falling water drops

IP22Protected against foreign solids with the diameter ≥ 12,5 mm and against vertically falling water drops, when the enclosure is at the angle of 15°

IP23 Protected against foreign solids with the diameter ≥ 12,5 mm and against water falling as rain

IP33 Protected against foreign solids with the diameter ≥ 2,5 mm and against water falling as rain

IP44 Protected against foreign solids with the diameter ≥ 1,0 mm and against complete sprinkling

IP54 Dust-protected against foreign solids and protected against complete sprinkling

IP55 Dust-protected against foreign solids and protected against water jets

Page 111: Hydraulic Turbines

5, Moldavskaya Str., Moscow, 121467, Russia +7 (495) 411-77-57, [email protected], www.oilgassystems.com

111

15.4. Climatic versions (in compliance with GOST 15150)Designation Climatic version of products

Products are designed for operation on shore, rivers and lakes

N For macroclimatic areas with temperate climates

NF For macroclimatic areas with temperate and cold climates

F For macroclimatic areas with cold climates

T For macroclimatic areas with both dry and wet tropical climates

UFor all macroclimatic areas on land, except for macroclimatic areas with extremely cold climates(general climatic version)

15.5. Categories of location (in compliance with GOST 15150)Designation Characteristics

1 For open air operations (impacted by set of climatic factors specific to the macroclimatic area)

2For operations under the shed or within premises (space) where air temperature and humidity fluctuations differ only insignificantly from the open air fluctuations, and there is relatively free access to outside air – for example, in tents, cargo platforms, trailers, metal containers without thermal insulation, and in the shell of category 1 packaged products (no direct sun light and precipitation impact)

3

For operations in closed premises (space) with natural ventilation and no artificially controlled climates, where air temperature and humidity fluctuations and sand and dust impacts are significantly smaller than in the open air – for example, in metal premises with thermal insulation, brick and concrete premises, wooden premises (no precipitation or direct sun light impact; significantly reduced wind forces; significantly reduced or no impact from scattered sunlight and moisture condensate)

4For operations in premises (space) with artificially controlled climates – for example, in closed heated premises or in cooled and ventilated industrial and other types of premises, including well- ventilated underground premises (no impact from precipitation, direct sun light, wind, or dust and sand; significantly reduced or no impact from scattered sunlight and moisture condensate)

5For operations in premises (space) with high humidity (for example, in non - heated and non - ventilated underground premises, including mines, cellars, in the soil; on vessels or boats that may have water for long periods of time, or have frequent moisture condensation on the walls and ceiling, namely in some cargo holds, certain textile and hydrometallurgical industry workshops, and others)

15.6. Rated operation mode (in compliance with GOST К 52776)Designation Description

S1 Long-term operation

15.7. Explosion protection types and levels (in compliance with GOST R MEK 60079-0)

Designation Description

IExdIIBT4 GbExplosion proof electrical equipment, group II, sub-group IIB, with the type of explosion protection “explosion proof enclosure d” for temperature class T4

IExdeIIBT4Explosion proof electrical equipment, group II, sub-group IIB, with the type of explosion protection “explosion proof enclosure d”, provided by protection of type “е”, for temperature class Т4

IExdeIICT3Explosion proof electrical equipment, group II, sub-group IIC, with the type of explosion protection “explosion proof enclosure d”, provided by protection of type “е”, for temperature class Т2

IExdeIICT4Explosion proof electrical equipment, group II, sub-group IIC, with the type of explosion protection “explosion proof enclosure d”, provided by protection of type “е”, for temperature class T4

IExpxIIT5XExplosion proof electrical equipment of group II with the type of explosion protection “casing filling or purging under Px excess pressure valve”, for temperature class T5; manufacturer does not provide installation of protective devices

PB Exdl Mining explosion proof electrical equipment of group I with the type of explosion protection ”explosion-proof enclosure d”

2ExdIICТ3Explosion proof electrical equipment of advanced protection against explosion group II, sub-group IIC, with the type of explosion protection

”explosion proof enclosure d”, for temperature class T3


Recommended