HYSPEC - HYSPEC - Hy Hy brid brid Spec Spec trometer trometer for the Single Crystal and for the Single Crystal and Polarized Neutron Studies at Polarized Neutron Studies at the SNS the SNS Steve Shapiro and Igor Zaliznyak Steve Shapiro and Igor Zaliznyak Center for Neutron Scattering and Neutron Scattering Group Brookhaven National Laboratory Brookhaven National Laboratory • Unique in its class • Highest flux on small samples • Easily adapted for polarized neutron studies
Transcript
Page 1: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC - HYSPEC - HyHybrid brid SpecSpectrometer for trometer for the Single Crystal and Polarized the Single Crystal and Polarized

Neutron Studies at the SNSNeutron Studies at the SNSSteve Shapiro and Igor ZaliznyakSteve Shapiro and Igor Zaliznyak

Center for Neutron Scattering and Neutron Scattering Group

Brookhaven National LaboratoryBrookhaven National Laboratory

• Unique in its class

• Highest flux on small samples

• Easily adapted for polarized neutron studies

Page 2: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

OutlineOutline

• Motivation (SMS)• Science Case (SMS)• IDT and Budget (SMS)• Conceptual Design (IZ)• Performance and Comparison(IZ)• Summary (IZ)

Page 3: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

StatusStatus Fall, 1999

BNL initiates an effort to design a spectrometer for the SNS December, 2000

Concept of the Hybrid Spectrometer formulated and adopted March, 2001

First presented to EFAC. Received positive reply Fall, 2001

Instrument Development Team formed October: Workshop on the Hybrid Spectrometer held at BNL Refined HYSPEC concept presented to EFAC

January, 2002 HYSPEC IDT filed Letter of Intent with SNS

April, 2002 Formal presentation to EFAC

July, 2002 Letter of Intent accepted; Submit Scientific Proposal to EFAC

Page 4: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

MotivationMotivation

A and B category top priority - “potential day-one instrument”1 Report on the SNS Inelastic Neutron Scattering Workshop, SNS Document IS-1.1.8.2-8004-MM-A-00 (2000).

BS

HRCS

CNCS

ARCS

HYSPECHYSPEC

SNS Inelastic Neutron Scattering Workshop1

Argonne (11/99)

Page 5: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Motivation from WorkshopMotivation from Workshop

Small single crystal samples Focussing Bragg optics

Broad range of standard sample environments Use of collimators and beam definers Sample environment separate from detector vacuum

Low background Time of flight Sample area out of direct beam Use of collimators

Vector Q in single crystals Moveable detector and rotatable sample

Polarization Analysis Proven and maintenance-free technology

Page 6: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Motivation from WorkshopMotivation from Workshop

Page 5 of Report:

“This [high time averaged flux] opens up the possibility of utilizing triple-axis like methods to examine details of excitations when the important physics can be found at specific, well defined regions of Q and E space”

Recommended: “potential day-one instrument”

Page 7: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Science CaseScience Case

Quantum critical pointsLow-D magnetismNanomagnetism and complex systemsDisordered and weakly ordered phasesAnomalous phonon behaviorStrongly correlated electron systems

– Hi Tc: YBCO experiment performed at ILL - IN22

Page 8: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Polarized Neutron Study on Resonant Polarized Neutron Study on Resonant Mode in YBCOMode in YBCO6.85 6.85 (L.P. Regnault et al.)(L.P. Regnault et al.)

IN22Spin FlipP // Q

Rise due to increased counting time

• Much faster data collection

• Open new areas for polarized beam use

Sharp IC

Broad C

Unpolarized

Page 9: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

IDT MembershipIDT MembershipI. Zaliznyak, co-PI BNL HYPSEC INSTRUMENTHYPSEC INSTRUMENT

S. M. Shapiro, co-PI BNL DESIGN WORKING GROUPDESIGN WORKING GROUP

G. Shirane BNL

J. Tranquada BNL I. Zaliznyak (BNL)

L. Passell BNL S. Shapiro (BNL)

D. Abernathy SNS L. Passell (BNL)

L. Daemen Los Alamos V. Ghosh (BNL)

M. Greven Stanford (Monte Carlo Simulations)

B. Gaulin McMaster S. Doran (SNS/ANL)

K. Hirota ISSP (Engineering Design)

V. Kiryukhin Rutgers

G. Lander EITU

Y. Lee MIT

C.Majkrzak NIST

S. Nagler ORNL

R. Osborn ANL

L. P. Regnault CEN-Grenoble

J. Rhyne U. Missouri

C. Stassis Ames/Iowa St.

A. Zheludev ORNL

Page 10: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC IDT Organization ChartHYSPEC IDT Organization Chart

BNLBNL

Advisory CommitteeAdvisory Committee

Executive CommitteeS. Shapiro, I. ZaliznyakProject manager (TBD)

Executive CommitteeS. Shapiro, I. ZaliznyakProject manager (TBD)

SNS Instrument Group(SNS, ANL)

SNS Instrument Group(SNS, ANL)

Monte-Carlo simulationsL. Passell (BNL)

L. Daemen (LANL)

Monte-Carlo simulationsL. Passell (BNL)

L. Daemen (LANL)

Design Studies (V. Ghosh, … BNL)Design Studies

(V. Ghosh, … BNL)

Neutron Polarization TechniquesC. Majkrzak (NIST)

L.-P. Regnault (CEN-Grenoble)

Neutron Polarization TechniquesC. Majkrzak (NIST)

L.-P. Regnault (CEN-Grenoble)

Mechanical SystemsC. Stassis (Iowa State)Mechanical Systems

C. Stassis (Iowa State)

Neutron Beam Polarization(L. Passell, … BNL)

Neutron Beam Polarization(L. Passell, … BNL)

ShieldingShutters

Beam stop

ShieldingShutters

Beam stop

ChoppersChoppers

InstallationInstallation

ElectronicsElectronics

Mechanical Systems (Ames)Monochromator Drum

Analyzer vessel

Mechanical Systems (Ames)Monochromator Drum

Analyzer vessel

Detector Systems (Instrumentation Division, BNL)

Detector Systems (Instrumentation Division, BNL)

Engineering (BNL, ANL, TBD)

Engineering (BNL, ANL, TBD)

Software(LANL, SNS)

Software(LANL, SNS)

SoftwareSoftware

….….

Page 11: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC Budget EstimateHYSPEC Budget EstimateBudget estimates from:

• SNS engineering group (11/01)

• HRCS Summary (7/02)

Time Estimate:

• 5 years from funding

Primary Flight Path      

  Choppers   1400

  Incident beam shielding   2300

  Supermirror guides   500

  Beam monitors   100

    SUB 4300

Monochromator      

  Shielding   1000

  Crystals and holder   400

  Collimators   50

    SUB 1450

Sample Stage      

  Goniometer, sample table   160

  Ancillary equipment   250

    SUB 410

Analyzer, detector      

  Collimator sets   200

  Polarization benders   1000

  PSD, electonics mounts   900

  Beam Controls-DAQ   140

  Detector vessel   1500

  Beam stop/get lost pipe   200

    SUB 3740

  CAPITAL TOTAL   9900

  LABOR (1/3 Capital)   3300

  TOTAL   13200

Page 12: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPECHYSPEC: A Proposed Crystal-Time-of Flight : A Proposed Crystal-Time-of Flight HyHybrid brid SpecSpectrometer for the Spallation Neutron Sourcetrometer for the Spallation Neutron Source

Part 2: Conceptual design

T0 Chopper

Disc Chopper

Monochromator

Goniometer

Radial Collimator,or Bender Polarizers

Flight Chamber (evacuated or Ar/He filled)

Detectors

Page 13: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Why Hybrid Spectrometer?Why Hybrid Spectrometer?

Monochromator vertical focusingMonochromator vertical focusing gaingain on SPINS@NIST: factor ~3factor ~3 even for m = 19 gm = 19 g sample (below)

Science challengesScience challenges

• small samples

• subtle features

• polarization analysis

• small signals, background-limited measurements

Need intensity boostNeed intensity boost

II00

3 x I3 x I00

Page 14: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

0 20 40 60 80 100108

109

1010

Ne

utr

on

cu

rre

nt

en

teri

ng

th

e g

uid

e (

n/s

)

Incident neutron energy Ei (meV)

Neutron current through 4x12cm2 guide entrance at 1.5 m from the moderator within E=2% of E

i

20 K coupled H2 (NISP interpolation)

20 K coupled H2 (MCSTAS interpolation)

H2O (MCSTAS interpolation)

MC calculation by E. Iverson

HYSPEC design choices: moderatorHYSPEC design choices: moderator

2.0*1012

1.6*1012

1.2*1012

0.8*1012

0.4*1012

0.0

20K H2 (decoupled)

Inte

nsi

ty (

n/s

R/μ

s/e

V/p

uls

e)

Coupled supercritical H2 moderator wins in thermal neutron range Ei<45meV

ambient H2O

0 100 200 300 400 500 600Time (μs)

Time-spectra of the neutron intensity from different moderators for EEii = 15.8 meV = 15.8 meV

Moderators useful neutron flux

coupled 20K H2

ambient H2O

Figure of merit is the total flux within t = 40-80 40-80 ss time window accepted by the spectrometer.

20K H2 (coupled)

Page 15: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC design choices: energy resolutionHYSPEC design choices: energy resolutiontt t/tt/tff E/EE/Eff

EEff=5.0 meV =5.0 meV 40 μs 0.0087 1.74%80 μs 0.0173 3.47%

EEff=15.0 meV=15.0 meV40 μs 0.015 3.0%80 μs 0.03 6.0%

EEff=30.0 meV=30.0 meV40 μs 0.021 4.25%80 μs 0.0425 8.5%

EEff=60.0 meV=60.0 meV40 μs 0.03 6.0%80 μs 0.06 12.0%

EEff=90.0 meV=90.0 meV40 μs 0.0368 7.36%80 μs 0.0736 14.7%

For given incident pulse length t instrument energy resolution is determined by the analyzer flight-path

Sample and detector size contribution to the instrument resolution is less than 0.5% each

TOF analyzer energy resolution for the length of the secondary flight-path LLSDSD=4.5 m=4.5 m and pulse lengths 40 μs to 80 μs is in the range 1.7% to 15%

Page 16: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC design choices: guide curvatureHYSPEC design choices: guide curvatureFlux on sample for different guide curvatures, parametrized by the corresponding offset at monochromator position.

Straight guide with m=3 supermirror coating is an optimal solution

0 20 40 60 80 100

105

106

107

HYSPEC flux simulated using MCSTASN

eut

ron

flux

on s

ampl

e (

n/s/

cm2 )

Energy(meV)

Beam offset at monochromator

0.0 cm 8.0 cm 12.0 cm 16.0 cm

Page 17: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC performance: vertical focusing gainHYSPEC performance: vertical focusing gain

Crystal-monochromator hybrid spectrometer (HYSPEC, top scheme) vs traditional “straight-through” TOF setup (MCST, bottom scheme).

HYSPEC wins except at 5 meV, where both concepts are rougthly equal.HYSPEC wins except at 5 meV, where both concepts are rougthly equal.

0 20 40 60 80 1000

2

4

6

8

Inte

nsi

tyH

YS

PE

C/I

nte

nsi

tyM

CS

T

Energy (meV)

simulation with MCSTAS

Page 18: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC performance: comparison with other HYSPEC performance: comparison with other inelastic instruments planned for the SNSinelastic instruments planned for the SNS

MC simulations by MCSTAS, V. Ghosh (2002)

CNCS, ARCS and HRCS intensities are re-scaled to HYSPEC energy resolution (such rescaling may over-estimate the actual intensity)

0 20 40 60 80 100

104

105

106

107

1CNCS model based on "Optimization...",J.V.Pearce et al. 2G.Granroth, Private communication

Neu

tron

flu

x on

sam

ple

(n/

s/cm

2 )

E (meV)

HYSPEC (no offset), coupled H2

CNCS1, coupled H2

ARCS2, H2O

HRCS2, H2O

Page 19: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC polarization analysis scheme: HYSPEC polarization analysis scheme: experimental demonstrationexperimental demonstration

S.-H. Lee, C. F. Majkrzak, Physica B 267-268, 341 (1999)

Heusler

Page 20: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC setup for polarization analysisHYSPEC setup for polarization analysis

Polarized incident beam is supplied by reflection from the vertically focusing Cu2MnAl (Heusler alloy) crystal monochromator

10meV < E10meV < Eiipolpol < 90meV < 90meV

Polarization analysis of the scattered neutrons is done by a set of 11-22 supermirror-bender transmission polarizers, each 2 cm wide, 5 cm thick and 15 cm high,

5meV < E5meV < Effpolpol < 25meV < 25meV

Page 21: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC layout in the polarized beam modeHYSPEC layout in the polarized beam mode

Page 22: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC performance in the polarized beam modeHYSPEC performance in the polarized beam mode

-10 -5 0 5 10 15 20

0

50

100

150

200Neutron energy 15meV

Inte

nsi

ty(a

rb.u

nits

)

Detector X co-ordinate (cm)

Bender width = 2cm All neutrons Spin up neutrons Spin down neutrons

Page 23: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC performance in the polarized beam modeHYSPEC performance in the polarized beam mode

0 5 10 15 20 25 30 350.0

0.2

0.4

0.6

0.8

1.0

Be

am

po

lari

zatio

n

Energy(meV)

Straight beam Deflected beam

Page 24: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

HYSPEC place in the SNS inelastic instrument suiteHYSPEC place in the SNS inelastic instrument suite

HYSPEC CNCS ARCS HRCSIncident energy range 5 – 90 meV 2 – 20(50?) meV 10 – 1000 meV 15 – 1000 meV

Maximum flux on sample

1.1 x 101.1 x 1077 at 15 meVat 15 meV

5.6 x 105.6 x 1066

at 5 meVat 5 meV7.8 x 107.8 x 1055

at 100 meVat 100 meV9.6 x 109.6 x 1055

at 100 meVat 100 meV

Energy resolution ΔE/E 0.017 – 0.15 0.01 – 0.1 0.02 – 0.05 0.015 – 0.05

Polarized beam YesYes NoNo NoNo NoNo

Intended sample size 4 (w) x2 (h) cm2 1.5 (w) x5 (h) cm2 5 (w) x7.5 (h) cm2 5 (w) x7.5 (h) cm2

Moderator-sample dist. 21.8m 36.2m 13.6m 17.5m

Sample-detector dist. 4.5 m 3.5 m 2.5 m 6.0 m

Angular acceptance 0.27 – 0.41 sR 3.1 sR 1.2 sR

Beamline # 15 5 18 17

Guide coating m = 3 m = 3.5 m = 3 – 3.5 m = 3 – 3.5

Guide Apertures (width x height, cm2)

entrance 4x12.8

main 4 x 15 exit 4 x 10

entrance 5 x 10main 5 x10 exit 1.5 x 5

Page 25: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

SummarySummary

HYSPEC will be a unique resource for probing correlations in condensed matter for

E [5,90] meV∈E [5,90] meV∈ E/E [0.05,0.15]∈E/E [0.05,0.15]∈

Q [0.3,10] ∈Q [0.3,10] ∈ ǺǺ-1-1 Q/Q [0.005,0.2]∈Q/Q [0.005,0.2]∈ Worlds most intense thermal neutron beam at a pulsed sourceWorlds most intense thermal neutron beam at a pulsed source Can optimize range of energy transfer and resolutionsand resolutions for

experiment Independent variation of Q and E resolution Polarization analysis capabilityPolarization analysis capability

The ultimate questionThe ultimate question: Do we need HYSPEC?LeadLead: Do we need 2 to 5 times larger flux2 to 5 times larger flux on sample compared to other SNS spectrometers and a polarized beam optionpolarized beam option?Our answerOur answer: Yes, we do.

Page 26: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Appendix. HYSPEC performance: monochromator Appendix. HYSPEC performance: monochromator resolution functionresolution function

14 15 16 17 180.0

2.0x105

4.0x105

6.0x105

8.0x105

1.0x106

Inte

nsi

ty (

arb

.un

its)

Incident energy(meV)

MCSTAS,15meVstraight guides

before PG after PG

Significant part of the incident beam intensity - in the unwanted high-E tail

Requires a pulse-shaping chopper in a standard TOF setup

Is removed by reflection from the monochromator in HYSPEC

Page 27: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Appendix. HYSPEC design choices: guide coatingAppendix. HYSPEC design choices: guide coating

Straight guide with m=3 supermirror coating is an optimal solution

Flux on sample for m=2, 3, and 3.5 supermirror guides (for 8 cm offset at the monochromator position).

0 20 40 60 80 100

105

106

107N

eu

tro

n f

lux

on

sa

mp

le(n

/s/c

m2 )

Energy(meV)

m=3.0 m=3.5 m=2.0

Page 28: HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.

Appendix. Intensity and pulse length of SNS Appendix. Intensity and pulse length of SNS moderatorsmoderators

1013

1012

1011

1010

109

103

102

101

100

10-1

10-1 100 101 102 103 104 105

Energy (eV)

E*I

(E)

(n/s

R/p

uls

e)

Pu

lse

len

gth

(F

WH

M,

μs)

20K H2 (decoupled)

20K H2 (coupled)

ambient H2O


Recommended