IBU-160i IBU-160i Intelligent Time Code Distribution Amplifier – Operation and Maintenance Manual P/N 900000152 REV A 1 Intelligent Time Code Distribution Amplifier IBU-160i Operation and Maintenance Manual P/N: 900000152 REV A For Brandywine Communications products with the following Part Numbers: 01900100X
Transcript
Page 1: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA1

IntelligentTimeCodeDistributionAmplifierIBU-160i

OperationandMaintenanceManual

P/N:900000152REVA

ForBrandywineCommunicationsproducts

withthefollowingPartNumbers:01900100X

Page 2: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA2

Safety Warnings

WARNING: This unit contains lethal AC voltages. Disconnect the unit from the AC supply before removing the cover.

WARNING:This unit contains dual power supplies. Isolate BOTH power supplied from AC Power before removing the top cover.

WARNING:The lightning flash with an arrowhead inside of an equilateral triangle is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure. The “dangerous voltage” may be of sufficient magnitude to constitute a risk of electrical shock to people. Do not attempt to repair the unit without first unplugging it.

CAUTION:The exclamation point inside of an equilateral triangle is intended to alert the user to the presence of important operation and maintenance instructions in the user guide. Only qualified personnel should repair this unit. Several board assemblies contain static sensitive devices. Appropriate procedures must be used when handling these board assemblies.

Page 3: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA3

RevisionHistory:Revision DateA 04/22/2016

Page 4: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA4

TableofContents

1 INTRODUCTION 5

2 UNPACKINGTHEIBU-160I 52.1 INSTALLATION 52.1.1 MOUNTING 52.1.2 POWER 62.1.3 ETHERNET 62.1.4 TIMECODEINPUTS 62.1.5 TIMECODEOUTPUTS 62.1.6 CONSOLEPORT 62.1.7 ALARMOUTPUTPORT 6

3 SETTINGUPTHEIBU-160I 7

4 ACCESSINGTHEIBU-160I’SNETWORKINTERFACE 84.1 ACCESSINGFUNCTIONSONTHEIBU-160I 84.1.1 VIEWINGTHECURRENTSTATUSOFTHEIBU-160ISYSTEM 9

5 CHANGINGTHESETTINGSONTHEIBU-160I 105.1 SELECTINGAREFERENCE 105.1.1 CHANGINGTHEREFERENCESWITCHMODE. 115.2 ADJUSTINGTHEOUTPUTSETTINGS 125.3 CHANGINGTHEIPADDRESS 135.4 CHANGINGSNMPSETTINGS 145.4.1 MONITORINGTHEIBU-160IUSINGSNMP 145.5 CHANGINGTHELOCATIONSETTING 155.6 CHANGINGTHEACCESSPASSWORD 16

6 ALTERNATEACCESS 176.1.1 USERCOMMANDSANDRESPONSES 17

7 SUPPORTINFORMATION 20

8 FRONTPANELVIEW 21

9 REARPANELVIEW 22

Page 5: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA5

1 IntroductionTheIRIGDistributorUnit(IBU-160i)provides16isolatedmodulatedtimecode

outputsbasedonaselectedinputreference.Thecodeoutputisalwaysthesameastheinput.TheIBU-160iprovidesreferenceselection,isolationandindividualamplitudeadjustment.

TheIBU-160iiscontainedinacompactIUrack-mountchassis.TheIBUacceptstwosetsofinputs,comprisingthereferenceIRIGinputandstatusfromthesource.TheIBUprovidesautomaticchangeovershouldoneoftheon-linesourceinputsfail.Manualsourceselectoverrideisavailableonthefrontpanel,orthroughtheEthernetinterface.

Avarietyofstatusindicatorsarelocatedonthefrontpanelforinstantvisualfeedback,togetherwithmanualcontrolsforsourceselection.

A10/100baseTEthernetinterfaceprovidesfullcontroloverthefunctionalityofthesystem,includingreferenceselectionandoutputamplitude(onaperchannelbasis).

Usercontroloftheunitisviaabuilt-inWebBrowserwithuser-friendlygraphicalinterface,orviaSNMPforsystemapplications.

ApplicationsfortheIBU-160iincludetestranges,satellitecontrolcenters,shipboardtimedistribution,airports,railterminals,andanysystemrequiringhighlyreliabletimecodedistribution.

2 UnpackingtheIBU-160iRemovetheIBU-160fromtheshippingcarton.Thefollowingitemsshouldbeincludedintheshipment:1xIBU-160i2xPowersupplycables1xQuickStartGuide

2.1 Installation

2.1.1 MountingTheIBU-160icanbeinstalledintoa19”rackmountcabineteitherusingrackslidesoronlyusingthefrontpanelflanges.Forstaticapplications,theshortdepthandlightweightoftheIBU-160iensuresthatthefrontpanelisnotstressedwhenonlythefrontpanelisusedforsupport.IftheIBU-160iisinstalledonamobileplatformandmustsurviveshockandvibration,theuseofslidesisrequired.Slidesareinstalledusing10-32UNF-2Bhardware.OptionalRackMountSlides:P/N002000123,SLIDE,RACK,24",21"TRAVEL,85LB

Page 6: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA6

P/N002000150,SLIDE,RACK,28",27"TRAVEL,80LBOriginalManufacturer:GeneralDevicesChassisTrakTypeC300.

2.1.2 PowerInsertthepowercordoftheIBU-160iintoanelectricalsockettopoweruptheunit.ThePowerLEDindicatorwillilluminategreen.Ifdualredundantpowerisrequired,connectbothpowersourcestoindependentpowersources

2.1.3 EthernetConnectoneendofanEthernetpatchcabletotheIBU-160iEthernetportJ21.ConnecttheotherendoftheEthernetcabletothenetworkwithanEthernethuborswitch.

2.1.4 TimeCodeInputsConnectatimecodeinputsourcestothetimecodeinputconnectorsJ17and/orJ18.ChannelAInputisJ18,andChannelBisJ17.

2.1.5 TimeCodeOutputsConnectthetimecodeoutputsJ1throughJ16tothecoaxialinfrastructure.

2.1.6 ConsolePortConnectaDB-9FcabletoportJ20inordertoenableRS-232accesstotheunit.(Straight,pin3isRXpin2isTX)

2.1.7 AlarmOutputPortConnectaDB-9McabletoportJ19toaccessthealarmoutputport.Pleaseseethefollowingdiagramforthepinoutoftheconnector:

Figure1-Alarmoutputpinout

Page 7: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA7

3 SettinguptheIBU-160iPoweronthesystembyflippingswitchesSW1andSW2ontherearoftheunittotheonposition.Thesystemwilldisplayitspower-oncycleonthefrontpanel.ThesystemwilluseLEDlampsD7throughD17toindicateeachoctetofthedevice’sIPAddress,NetworkMask,andGatewayaddress.Writethesevaluesdownandkeeptheminasafeplace.TodisplaytheIPaddressagain,thefrontpanelcanberesetbypressingtheRESETswitch(SW2)onthefrontpanel.

Figure2-IBU-160iShowingIPAddress

Page 8: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA8

4 AccessingtheIBU-160i’sNetworkInterfaceConnecttotheIBU-160ibyenteringtheunit’sIPaddressintotheaddressbarofthewebbrowseronaPC,SmartphoneorTablet.

Figure3-IBU-160iWebPageInterface

UsethedropdownmenutoselectdifferentfunctionsoftheIBU-160itoviewthestatusofthesystemandtoadjustdifferentfunctionsoftheunit.

4.1 AccessingFunctionsontheIBU-160i

ToaccessdifferentfunctionsoftheIBU-160imanagementwebpage,selectthebuttonlabeled“MENU”inthetoplefthandcornerofthewebpage.

Page 9: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA9

4.1.1 ViewingtheCurrentStatusoftheIBU-160isystemFromthe“MENU”button,select“General”fromthestatusmenu.Thisshowsinformationsuchasthecurrentoutputtime,UTCtime,uptime,thecurrentinputreference,thecurrentoutputformat,currentsystemstate,andalarmstatus.

Figure4-IBU-160iStatusPage

OutputTime:ThecurrenttimeofdaybeingdisplayedorbeingoutputbytheIBU-160iUTCTime:ThecurrenttimeofdayfromtheGPSconstellationinUniversalTimeCoordinate(UTC)UpTime:ThelengthoftimethattheIBU-160ihasbeenpoweredonHourMeter:ThisistheaccumulatednumberofoperatinghourssincetheIBU-160iwasfirstbuilt.Reference:ThecurrentreferenceinputbeingusedbytheIBU-160iSystemAlarms:IfthesystemiscurrentlydisplayinganyalarmsOutputUnits:Thecurrentunitthesystemisusing

Page 10: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA10

5 ChangingtheSettingsontheIBU-160i

Figure5-ReferenceSettingsPage

5.1 SelectingaReference

Fromthemenu,select“Reference”fromthesettingssubmenu.Fromthe“SelectReference”dropdownmenu,selectbetweenreferencesourcesA(J18)orB(J17).

Page 11: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA11

5.1.1 Changingthereferenceswitchmode.Fromthedropdownlabeled,“SelectReferenceSwitchMode,”selectwhichmodetheunitusestoswitchreferencesintheeventofaproblem.Theavailablemodesarelistedbelow.

• Non-Reversionary: Iftheprimaryreferencesourcefailsorisoutofthreshold,thesystemwillautomaticallyswitchovertothesecondaryreferencesource,andcontinuetousethesecondaryuntilmanuallyswitchedbacktotheprimarysource,orthesecondarysourcefailsandthesystemautomaticallyswitchesbacktotheprimary.

• Reversionary: Thesystemwillswitchtothesecondarysourceautomaticallyiftheprimarysourcefailsorisoutofthreshold,howeveroncetheprimarysourceisrestored,theunitwillimmediatelyswitchback

• ReversionarywithDelay: Thesystemwillautomaticallyswitchtothesecondarysourceintheeventtheprimarysourcefailsorisoutofthreshold.Oncetheprimarysourceisrestored,itwillautomaticallyswitchbackafterwaitingforauser-specifieddelay.Thissettingisusefulforhelpingtheunitdealwithintermittentproblemsonaprimarytimecodesource.

5.1.1.1 Adjustingthereversionarydelay.Thetextbox“ReversionaryDelay”isusedtosetthedelaytimeinsecondsusedwhenthesystemissettothe“ReversionarywithDelay”ReferenceSwitchmode.

Page 12: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA12

5.2 AdjustingtheOutputSettings

Figure6-OutputSettings

Fromthemainmenu,select“Output”fromthesettingssubmenu.ThisletstheuserchangetheOutputlevelsofeachindividualtimecodeoutput.

Page 13: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA13

5.3 ChangingtheIPAddress

Fromthemainmenu,select“IP”fromthesettingssubmenu.Fromhere,theIPAddress,SubnetMask,andGatewayaddressoftheunitcanbeselected.Inaddition,itispossibletoenableDHCP,howeverthisactionisnotrecommended.

Figure7IPAddressSettings

Page 14: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA14

5.4 ChangingSNMPSettings

Fromthemainmenu,select“SNMP”fromthesettingssubmenu.FromheretheReadCommunity,WriteCommunity,andTrapIPAddresscanbeset.

Figure8-SNMPSettings

5.4.1 MonitoringtheIBU-160iusingSNMPTomonitortheIBU-160iviaSimpleNetworkManagementProtocol(SNMP),downloadaMIBfilefromtheSupportDownloadssectionoftheBrandywineCommunicationswebsite.(http://www.brandywinecomm.com/product-support/downloads)

Page 15: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA15

5.5 ChangingTheLocationSetting

Fromthemainmenu,select“Location”fromthesettingssubmenu.Thissettingtellstheuserwheretheunitisphysicallylocatedwithinafacility.(e.g.Room102)

Figure9-LocationSettingScreen

Page 16: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA16

5.6 ChangingTheAccessPasswordFromthemainmenu,select“Password”fromthesettingssubmenu.Fromheretheaccesspasswordfortheunittopreventotherusersfromchangingsettingscanbeset.ThecurrentUsernameandPasswordarerequiredinordertoresettheexistingusernameandpassword.Thefactorydefaultlogincredentialsare:Username:BRANDYWINEPassword:BRANDYWINE

Figure10-PasswordSettings

Page 17: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA17

6 AlternateAccessIftheunitisinanareawhereitcannotbeaccessedoverthenetwork,butphysicalaccesstothedeviceisstillpossible,theIBU-160icanstillbeaccessedandcontrolledviaRS-232overtheserialport.

6.1.1 UserCommandsandResponses TheIBU-160iSerialport(115200,8,1,1,noparity)providesstatusandsettingdataonrequestfromtheuser.TheusercanobtaininformationfromtheIBU160ibysendingHELPcommandterminatedbyCR.TheIBU160iwilldisplaytheHELPMENUasbelow:

-----------------------------------------------------------------------------------------------IBU160iSystemSetup-(925000120)1.01.05Jul92013SN#36770-HardwareVer:A-----------------------------------------------------------------------------------------------COMMANDDescription----------------------------------------------------------------------------------------------HELP ShowthisscreenIPADDR IPAddress(setto0.0.0.0toenableDHCP)(192.168.1.121)IPMASK IPMask(255.255.255.0)IPGATEWAY IPGateway(192.168.1.1)MACADDR MACAddress(00-21-34-00-02-EB)FACT FactoryResettoDefaultsSettingRESET ResetSystemEnteramenucommand:

TheIBU-160iusercommandsaredescribedinthetablebelow.

COMMAND FUNCTION COMMENTS HELP ShowHelp ShowHelpMenu

Example:HELP<CR>DisplaystheaboveHelpMenu.

IPADDR SetIPAddress SettheIPAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.

Page 18: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA18

Example:IPADRR<CR>New Setting:192.168.1.121<CR> SetstheIPaddressto192.168.1.121anddisplaystheaboveHelpMenu.ToenableDHCPenterIPaddress0.0.0.0<CR>

IPMASK SetIPMaskAddress

Set/GettheIPMaskAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.Example:IPMASK<CR>New Setting:255.255.255.0<CR> SetsIPMaskanddisplaystheaboveHelpMenu.

IPGATEWAY SetGatewayAddress

Set/GettheGatewayAddress(decimalnumber)Gateway4,Gateway3,Gateway2,Gateway1andStoreintoNVM.ExampleIPGATEWAY<CR>NewSetting:192.168.1.1SetsIPGatewayanddisplaystheaboveHelpMenu.

MACADDR SetMACAddress Set/GettheMaskAddress(decimalnumber)Mask4,Mask3,Mask2,Mask1andStoreintoNVM.Example:MACADDR<CR>New Setting: 00-21-34-00-02-EB<CR>SetsMACaddressanddisplaystheaboveHelpMenu.

FACT RecallFactorydefaults

RecallallfactorydefaultsettingsExample:FACT<CR>

Page 19: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA19

Areyousureyouwanttocontinue(Y/N)?YResetstofactorydefaultanddisplaystheaboveHelpMenu.

RESET ResettheUnit ResettheUnitExample:RESET<CR>Areyousureyouwanttocontinue(Y/N)?YResetSystemResetstheunitanddisplaystheaboveHelpMenu.

Upgrade Application

UsePIC32BootloaderApplicationprogramtoupgrademainapplicationthroughEthernet.Followthebelowcommands:1. RunthePIC32UBL.exe2. ChecktheEthernetEnablecheckedbox.Make

suretheIPAddress=192.168.254.100.3. Hitthe“LoadHexFile”.Browseto“IBU-

160i.hex”tosendthehexfile.4. Hitthe“Upload”button. 5. Waitfortheprogressionbarstartingbefore

recyclethepowersupplysothattheprogramjumptobootloadersection.Thestatusshoulddisplaythebootloaderfirmwareversionsuchas"V1.1". Table 2

Page 20: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA20

7 TroubleshootingProblem Solution

TheIBU-160iDoesnotpoweron Pleaseensurethatthesystemiscorrectlypluggedintopower,andthatbothpowersuppliesareconnected.

TheIBU-160ipowerson,thelightsflashbriefly,andthennothing.

Thesystemfirmwareisnotproperlyloaded.PleasecontactBrandywineCommunicationsforsupport

TheIBU-160ipowersupcorrectly,butthelightsflasherraticallyonceit’spoweredon.

Thesystemdoesnothaveavalidinputreferencefromeitherinputconnection.Pleasedouble-checktheinputconnectors.

8 SupportInformationAllBrandywineCommunicationsproductscomewithaone-yearwarranty.Iftheunitisstillexhibitingproblemsnotcoveredbytheabovetroubleshootingguide,pleasecontactusfortechnicalsupportatsupport@brandywinecomm.comorcallusat714-755-1050.Ifitbecomesnecessarytoreturntheunittothefactoryforrepairs,pleasecallusat714-755-1050extension113toarrangeanRMA.

Page 21: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA

21

9 FrontPanelView

Page 22: IBU-160i (900000152) REV A · The IBU-160i can be installed into a 19” rack mount cabinet either using rack slides or only using the front panel flanges. For static applications,

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA

22

10 RearPanelView