The duplication of this report or parts of it and its use for advertising purposes is only allowed with permission of the testing laboratory. This report contains the result of the examination of the product sample submitted by the applicant. A general statement concerning the quality of the products from the series manufacture cannot be derived therefore. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government. IESNA SUSTAINING MEMBER Ref. No.: LCGP15030690 Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered to: EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 For products: LED Lamp Models: LED54WPT50KMOG-G5 Test date: Mar 13, 2015 to Mar 16, 2015 Test laboratory: LCTECH (Zhongshan) Testing Service Co.,Ltd 2/F.,Technology and Enterprise Development Center, Guangyuan Road, Xiaolan, Zhongshan, Guangdong, China Laboratory note: N/A Complied by: Reviewed by: Pang Bowen Richard Li Project Engineer Technical Manager Mar 17, 2015 Mar 17, 2015
Transcript
Page 1: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

The duplication of this report or parts of it and its use for advertising purposes is only allowed withpermission of the testing laboratory. This report contains the result of the examination of the product

sample submitted by the applicant. A general statement concerning the quality of the products from theseries manufacture cannot be derived therefore. This report must not be used by the customer to claim

product certification, approval or endorsement by NVLAP, NIST, or any agency of the FederalGovernment.

IESNASUSTAININGMEMBER

Ref. No.: LCGP15030690

Date of issue Mar 17, 2015

Version 1.0

Total pages: 11

Test report of

IES LM-79-08

Approved Method: Electrical and Photometric

Measurements of Solid-State Lighting Products

Rendered to:EiKO Global, LLC23220 W. 84th St., Shawnee, KS 66227

For products:LED Lamp

Models: LED54WPT50KMOG-G5

Test date: Mar 13, 2015 to Mar 16, 2015Test laboratory: LCTECH (Zhongshan) Testing Service Co.,Ltd

2/F.,Technology and Enterprise Development Center, Guangyuan Road,Xiaolan, Zhongshan, Guangdong, China

Laboratory note: N/A

Complied by: Reviewed by:Pang Bowen Richard LiProject Engineer Technical ManagerMar 17, 2015 Mar 17, 2015

Page 2: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 2 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

Table of Contents1 General ..................................................................................................................... 3

1.1 Product Information ...................................................................................... 31.2 Standards or methods ................................................................................. 41.3 Equipment list................................................................................................ 4

2 Test conducted and method............................................................................... 52.1 Ambient Condition ........................................................................................ 52.2 Power Supply Characteristics..................................................................... 52.3 Seasoning and Stabilization ....................................................................... 52.4 Electrical Instrumentation ............................................................................ 52.5 Color Measurement Method ....................................................................... 52.6 Total Luminous Flux Measurement Method............................................. 52.7 Luminous Intensity Distribution Measurement Method .......................... 52.8 Spatial Non-uniformity of Chromaticity...................................................... 5

3 Test Result Summary ........................................................................................... 63.1 Electrical data................................................................................................ 63.2 Photometric data........................................................................................... 6

4 Test Data .................................................................................................................. 74.1 Spectral Distribution ..................................................................................... 74.2 Chromaticity Diagram (CIE 1931) .............................................................. 74.3 ANSI Chromaticity Quadrangles Diagram ................................................ 84.4 Color Rendering Details .............................................................................. 84.5 Goniometry Test Data.................................................................................. 94.6 Zonal Lumen Summary ............................................................................... 94.7 Polar Curves................................................................................................104.8 Candela Tabulation ....................................................................................11

Page 3: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 3 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

1 General1.1 Product InformationBrand Name -Trade Mark -Luminaire Type LED LampModel Number LED54WPT50KMOG-G5Rated Inputs 100-277VAC,50/60HzRated Power 54 WRated Initial Lamp Lumens 6480 lmDeclared CCT 5000 KLED Package, Array or Module Not pivotedDate of Receipt Samples Mar 12, 2015Quantity of Receipt Samples 1 unit

Photo

Picture 1

Picture 2

Page 4: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 4 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

1.2 Standards or methodsThe following standards are partly or totally used or referenced for test:

No. NameANSI/NEMA/ ANSLGC78.377-2011

Specifications for the Chromaticity of Solid State LightingProducts

ANSI C82.77-2002 Harmonic Emission Limits Related Power QualityRequirements for Lighting Equipment

CIE Pub. No. 13.3-1995 Method of Measuring and Specifying Color Rendering of LightSources

CIE Pub. No. 15:2004 ColorimetryIES LM-79-08 Electrical and Photometric Measurements of Solid-State

Lighting Products

1.3 Equipment listID Instrument Model name Cal. date Next cal. Date

AC Power supply LC-I-923 CHP-500 2015-02-05 2016-02-04AC Power supply LC-I-987 APW-110N 2015-02-05 2016-02-04Power analyzer LC-I-928 WT210 2015-02-09 2016-02-08Power analyzer LC-I-954 WT210 2015-03-04 2016-03-03

Multimeter LC-I-972 Fluke 17B 2014-08-15 2015-08-14Photometric colorimetric

electric system(2 meter sphere)

LC-I-900 SPR3000 Before use Before use

Standard lamp LC-I-971 STD-ESN 2014-05-16 2015-05-15Goniophotometer(with

mirror)LC-I-902 GMS2000 2014-05-14 2015-05-13

Wireless temperaturetransmitter

LC-I-958 DWRP-B(0) 2014-08-19 2015-08-18

Wireless temperaturetransmitter

LC-I-959 DWRP-B(0) 2014-08-19 2015-08-18

Page 5: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 5 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

2 Test conducted and method2.1 Ambient ConditionThe ambient temperature in which measurements are being taken was maintained at 25 C1 C, the air flow around the sample(s) being tested did not affect the performance.2.2 Power Supply CharacteristicsThe AC power supply had a sinusoidal voltage wave shape at the prescribed frequency (60 Hz)such that the RMS summation of the harmonic components does not exceed 3 percent of thefundamental during operation of the test item.The voltage of AC power supply (RMS voltage) applied to the device under test was regulatedto within 0.2 percent under load.2.3 Seasoning and StabilizationNo seasoning was performed in accordance with IESNA LM-79-08. And before themeasurement, the sample was stabilized until the light output and power variations were less than 0.5% in 30 minutes intervals (3 readings, 15 minutes apart).2.4 Electrical InstrumentationThe calibration uncertainties of the instruments for AC voltage and current were less than 0.2percent, and the calibration uncertainty of the AC power meter was less than 0.5 percent(95 %confidence interval, k=2).2.5 Color Measurement MethodSpectral radiant flux was measured by a sphere (2 meter)-spectroradiometer system, and the color characteristics (Color rendering index, correlated color temperature, chromaticitycoordinate) were calculated from these by software automatically.2.6 Total Luminous Flux Measurement MethodTotal luminous flux was measured by both sphere-spectroradiometer system andgoniophotometer.Spectral radiant flux was measured by a sphere (2 meter)-spectroradiometer system, and the total luminous flux was calculated from these by software automatically.Luminous intensity distribution was measured by a mirror-type goniophotometer (Type C)which can keep the sample in burn position when the tests conduct, and the total luminous fluxwas calculated from the intensity data by software automatically.2.7 Luminous Intensity Distribution Measurement MethodLuminous intensity distribution was measured by a mirror-type goniophotometer (Type C)which can keep the sample in burn position when the tests conduct, and the kinds of graphwere generated by software automatically.2.8 Spatial Non-uniformity of ChromaticityThe customer did not require this measurement.

Page 6: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 6 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

3 Test Result Summary3.1 Electrical data

Criteria ItemResult

(Sphere)Result

(Goniophotometer)Input Voltage 277.0 V~60Hz 277.04 V~60HzInput Current 0.212 A 0.212 ATotal Power 51.29 W 51.18 W

Power Factor 0.875 0.871I-THD 16.32 % -

Off-state Power 0.0 W -

3.2 Photometric data

Criteria ItemResult

(Sphere)Result

(Goniophotometer)Total Lumens 6579.5 lm 6636.21 lm

Luminaire Efficacy 128.28 lm/W 130.00 lm/WCorrelated Color Temperature (CCT) 5087K -

Color Rendering Index (CRI) 82.3 -R9 3 -

Chromaticity Coordinate (x,y) x= 0.3436 y= 0.3611 -Chromaticity Coordinate (u,v) u= 0.2068 v= 0.3260 -Chromaticity Coordinate (u ,v ) u = 0.2068 v = 0.4890 -

Duv 0.0053 -

Note: N.A.

Page 7: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 7 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

4 Test Data4.1 Spectral Distribution

4.2 Chromaticity Diagram (CIE 1931)

Page 8: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 8 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

4.3 ANSI Chromaticity Quadrangles Diagram

4.4 Color Rendering DetailsR1 R2 R3 R4 R579 86 92 83 81R6 R7 R8 R9 R1083 87 66 3 69

R11 R12 R13 R14 R1582 67 81 96 73

Page 9: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 9 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

4.5 Goniometry Test DataCIE Type General Diffuse Basic Luminous Shape Rectangular w/SidesSpacing Criteria (0-180) N.A. Luminous Length 0.08 m (Diameter)Spacing Criteria (90-270) N.A. Luminous Width 0.08 m (Diameter)Spacing Criteria (Diagonal) N.A. Luminous Height 0.15 mTest Distance 30.00 m

4.6 Zonal Lumen Summary

Page 10: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 10 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

4.7 Polar Curves

Page 11: IESNA SUSTAINING MEMBER › CutSheets › 651398C7-D476-4A1E... · Page2of11 Ref.No.:LCGP15030690 LCTECH(Zhongshan)TestingServiceCo.,Ltd. Add:2/F.,TechnologyandEnterpriseDevelopment

Page 11 of 11 Ref. No.: LCGP15030690

LCTECH (Zhongshan) Testing Service Co.,Ltd.Add: 2/F.,Technology and Enterprise Development

Center, Guangyuan Road, Xiaolan,Zhongshan, Guangdong, ChinaTel:+86-760-22833366 Fax:+86-760-22833399 E-mail:[email protected] http://www.lccert.com

4.8 Candela Tabulation

****End of test report****