  • 8/9/2019 IM Series Counter Service.pdf

    1/14

    Avery Weigh- Tronix Technical Specification IM Series

    Overview

    General Description

    The IM series provides a range

    of counter scales to cover the

    different requirements of fresh

    food counters, self-service,

    pre-pack areas and point of sale

    areas for supermarkets and

    speciality stores.

    These terminals may be used

    in stand-alone mode or linked

    together to form networks.

    In addition, the different

    departments can be linked

    together and connected to a

    back office computer, to form

    store-wide, centrally managed

    networks.

    The scales can operate in a

    number of different modes,printing individual labels for

    each item or combining the

    shoppers items together and

    printing a single receipt.

    Build Types and

    Description

    IM 100

    Monobloc scale - a compact

    weighing terminal withintegrated vendor and

    customer display.

    42 pre-set key keyboard.

    IM 202

    Head up Display (HUD) for both

    the customer and the vendor

    are mounted on the tower.

    This model features an

    extended, 60 pre-set key

    keyboard.

    IM 300

    Self-Service scale providing 80

    pre-set, assignable keys placed

    on a large keyboard mountedon the display column. An

    additional 80 key keyboard can

    also be added providing a total

    of 160 keys.

    The keyboard provides full

    travel keys with a side loading

    protective envelope allowing

    insertion of a product-legended

    keyboard. Keys can be doubled

    or arranged in groups of four to

    allow larger sized keys.

    IM 400Two-piece scale with the

    keyboard and both displays

    mounted on the tower column.

    This maximises eye-level

    interaction between operator

    and customer. 40 key preset

    keyboard.

    IM 500

    The hanging scale is bracket

    mounted with attached

    suspended weighing plate.

    Integrated printing mechanism.

    40 pre-set key keyboard. A pole

    kit is available as an accessory.

    IM SeriesCounter Service Scales

  • 8/9/2019 IM Series Counter Service.pdf

    2/14

    Dimensions IM100 (w x d x h) 374 x 407 x 169mm - 14.7 x 16.0 x 6.7 in

    IM202 (w x d x h) 374 x 444 x 535mm - 14.7 x 17.5 x 21.1 in

    IM300 (Single keyboard) (w x d x h) 374 x 444 x 612mm - 14.7 x 17.5 x 24.1 in

    IM400 (w x d x h) 374 x 346 x 530mm - 14.7 x 13.6 x 20.1 in

    IM500 (Not including hanger and pan) 372 x 346 x 344mm

    (w x d x h) 14.6 x 6.1 x 13.5 in

    Feet Spacing all models except 270 x 234mm

    IM500 (w x d) 10.6 x 9.2 in

    Capacities Standard IM 100 - 400 IM500 15kg AVR - 30lb x 0.01lb 15kg x 5g

    Cost option IM100 - 400 x 0.01lb 6kg AVR, 12kg x 2g, 30kg x 5g, 50lb

    Power Consumption Non Printing 18VA

    Connections RJ45 Ethernet, RJ12 Cash Drawer,

    proprietary serial, 2 x USB

    Memory Size 1.5MB

    No. PLUs 6000 @ 16 chars/plu

    Networking Interscale Ethernet 10/100 base-T, max 10

    scales per network, max. 20 operators

    Interscale network resilience Back up server

    Host i/f Ethernet 10/100 base-T

    Number host networks/servers unlimited

    WiFi Optional self fit module 802.11b/g compliant

    Display Operator Blue LED backlit, dot matrix, 192 x 64 pixel

    Customer Blue LED backlit, dot matrix, 192 x 64 pixel

    Keyboard Type Pressure sensitive with tactile domes on

    number/function keys

    No. preset PLUs 42 on IM100, 400, 500 - 60 on IM202

    Self Service keys - type Tactile, full travel keys beneath membrane

    No. Self Service Keys 80 single IM300 keyboard

    160 optional dual IM300 keyboard

    Printer Type Thermal Label/Receipt

    Roll diameter/width Max. 100/60mm or 4/2.4 in

    Speed Max. 80mm/s or 3.1in/s

    Labels Print dimensions (w x l) Max. 56 x 160mm or 2.2 x 6.3 in

    Graphics Yes, max. 5

    No. Fonts 24

    No. Formats 12, all flexible

    Label orientation 0, 90, 180

    Field orientation 0, 90, 180, 270

    Print boxes, frames, lines Yes

    Operating Modes Label, Receipt, ECR, Prepack

    Barcodes Barcodes supported EAN 8, UPC 12, EAN 13, UPC 13,

    Scandinavian, EAN128, RSS Expanded

    (GS1 Databar), RSS14, RSS Limited

    IM Series Avery Weigh- Tronix Technical Specification

    At a Glance Specifications

    2

  • 8/9/2019 IM Series Counter Service.pdf

    3/14

    Avery Weigh- Tronix Technical Specification IM Series

    Traceability No. schemes 3

    GTIN support Yes

    Batch weight Yes

    Expiry date Yes

    Carcass Records 99Other software 2 PLU text areas, 1500 characters each, Support of: Promotions, Nutripanels, Dual

    features currency pricing, PLU search, Audit Trail and transaction collection, 3 security levels, 10

    departments, 21 sales messages, 4 tax rates, 9 tares, 9 discount rates, 5 payment keys,

    Vertical scrolling messages, Cash up.

    Hardware

    Processor/Memory

    All IM series scales use an ARM,

    32-bit processor.

    All user-programmable data

    is stored in reprogrammable

    Flash memory. The number of

    PLUs supported is dependant

    on the average text size, number

    of totals used etc. Typically,

    there will be sufficient memory

    for at least 6000 PLUs

    The following table clearly lists

    the average text size in relation

    to the number of PLUs available.

    The table shows PLU capacity

    with two totals types per PLU

    and eight totals types per PLU,

    according to different average

    text size. Up to 12 totals types

    could be stored per PLU (sales,

    counter, pre-pack, override,

    return and promotions). Each

    total type can be stored across

    two reporting periods.

    Other factors which affect PLU

    memory size include:

    Receipt memory

    Transaction per receipt memory

    Diagnostic log size

    Traceability record memory

    Traceability totals memory

    There is an additional, separate

    flash memory which is used for

    the application software and

    factory default data. This ensuresPLU memory capacity remains

    unaffected by software updates.

    Displays

    All IM series customer and

    vendor displays are blue LED

    backlit, LCD dot-matrix 192 x

    64dot resolution displays.

    The top left-hand corner of the

    display is reserved to display

    the model number. Metrological

    data is displayed in the box next

    to this.

    Different character sets can be

    supported for various countries,

    including Latin, Greek, Cyrillic

    and Arabic.

    Displays can be adjusted for

    different lighting and viewing

    angles, via a contrast adjustment

    in management mode.

    Display annunciators emphasise

    the current mode of operation,

    including: fix/pre-pack, net/tare,

    price base and zero. These

    modes are dependant on

    the market.

    The unit price field allows up

    to four digits before a thousand

    separator is displayed.

    Printers

    The IM series printer is a heavy

    duty label and receipt printer,

    with a single motor driving both

    the paper feed and paper rewindsystems. Receipt tally roll, die

    cut labels or continuous sticky

    paper can be used.

    The paper roll is loaded onto

    the spindle and the paper

    passed through the large

    aperture at the rear of the open

    print mechanism. The single

    large aperture through which the

    paper is fed at the rear of the

    print mechanism means paper

    changes are quick and simpleand makes it virtually impossible

    to feed the paper through the

    printer incorrectly.

    To ensure the print head can be

    easily cleaned, the print head is

    raised well clear of the lower

    body when in the open position

    ensuring good access. This easy

    maintenance feature encourages

    cleaning to be carried out and the

    life of the print head optimised.

    The printer also auto-rewinds

    before printin commences,

    ensuring a minimum of dead

    space on the label or receipt.

    3

    1.5 MB 2 Totals 8 TotalsAverage Text Size No. of PLUs No. of PLUs

    16 6000 6000

    24 6000 6000

    50 6000 5557

    100 6000 4736

    250 4167 3334500 2557 2217

    750 1852 1667

    1000 1447 1331

    1250 1191 1111

    1500 1009 951

  • 8/9/2019 IM Series Counter Service.pdf

    4/14

    IM Series Avery Weigh- Tronix Technical Specification

    Metric Imperial

    Maximum Roll Size 100mm 4 in

    Maximum width 60mm 2.5 in

    Maximum print width 56mm 2.2 in

    Print speed 80mm/s 3.1 in/s

    Printer specification:

    Keyboards

    The IM series keyboards fitted

    to the scale are hard-wearing,

    touch sensitive, wipe clean

    keyboards with raised pre-

    programmed and digit keys.

    The raised keys give a near

    tactile feel when used and give

    the operator feedback that their

    finger is located correctly on

    the key.

    The IM series keyboard is

    available in two options, a 66

    key variant for all versions where

    the display and keyboard are

    mounted together, and an 84

    key variant for the IM 202 head

    up display version.

    The raised section of the

    keyboard has a number of pre-

    programmed functions assigned

    to it (eg: 0-9, Clear, Test, Enter,

    Total / Print, Add, Tare, etc).

    Each variant also has a

    user-programmable area of 42

    (IM100, 300, 400, 500) and 60

    (IM202) keys.

    The user programmable areas

    comprise of hard-wearing, tear-resistant transparent pockets

    under which a user-defined

    insert may be slotted into place.

    Four tough, flexible plastic

    inserts are supplied with the

    scale. They can be written on

    with a non-permanent felt

    marker which can be erased if a

    change to the user-programmed

    key is made in the future. The

    reverse side of the insert

    contains all keys required when

    programming the scale.

    Latin, Greek, Cyrillic and Arabic

    character sets are delivered,

    one on each insert. The insert

    is retained at the lower edge

    by two ridges in the plastic

    moulding.

    Self-service keyboards for

    IM 300

    The IM 300 is delivered with an

    80 key self-service keyboard.

    This is mounted on a metal

    baseplate that sits beneath the

    scale. An optional second

    keyboard can also be ordered

    providing a total of 160 keys.

    This mounts to the same

    baseplate.

    The keyboard itself consists

    of full travel keys, with a

    transparent keyboard pocket

    that accepts a keyboard insert.

    Keys may be grouped in any

    combination of fours, twos or

    singles, providing full flexibility

    for larger keys where required.

    Weighing Capacities

    The IM series scales areavailable in the following

    standard capacities :

    For IM 100, 202, 300, 400:

    30 lb x 0.01 lb

    50 lb x 0.01 lb

    6 kg AVR

    12 kg x 2 g

    15 kg AVR

    30 kg x 5 g

    For IM 500 hanging scale:

    15 kg x 5 g

    30 lb x 0.01lb

    Power Supply

    The IM scale has an external

    plug-mounted power supply

    rated at 100V/60Hz to

    240V/50Hz. This connects to

    the underside of the scale. The

    cable can be held in a clip at the

    rear of the underside to providestrain relief on the DC connector.

    The use of the external power

    supply makes the scale a low

    voltage device, and reduces

    power consumption.

    All variants are supplied with

    interchangeable plug heads to

    suit the vast majority of socket

    types worldwide. Additionally,

    the plug head can be removed

    and a flying lead attached to theIEC C7 power connection of the

    power supply. This is useful if

    the power cable is of insufficient

    length or there is insufficient

    space at the power socket for

    the power supply.

    Scale Interfaces

    USB Ports

    All models feature two USBports, with USB V.1.1 being

    supported. On IM 100, 202, 300

    and 400 models, one port is

    located beneath the scale, one

    is located in the printer

    compartment. Typically, the port

    located beneath the scale may

    be used for scanner input.

    The port located in the printer

    compartment is typically used

    for data transfer with a USB

    memory stick.

    4

  • 8/9/2019 IM Series Counter Service.pdf

    5/14

    Avery Weigh- Tronix Technical Specification IM Series

    On the IM500 one USB port

    is located beneath the

    connector/WiFi cowl on the

    top of the machine and one

    is located beneath the

    connector/WiFi cowl on theoperator side of the machine.

    Cash Drawer Interface

    All models feature an RJ12

    connector for use with a 12

    or 24V cash drawer.

    Inter-scale Network

    and Host Computer

    Interfaces

    A maximum of 10 scales may

    be linked together in a single

    network.

    All communications are based

    on standard 10/100-BaseT

    Ethernet networking. Ethernet

    cabling standard IEEE802.3

    defines cable type, length and

    equipment.

    TCP/IP is the language or

    protocol, by which all devices

    communicate.

    Within a single network, scales

    are configured in a Client/Server

    configuration, with all scales

    sharing the same Ethernet port

    address.

    Any scale can be configured as

    the Server and all scales contain

    the full PLU and data file.

    As all scales are connected

    directly into an Ethernet hub,

    no wiring short-circuit can bring

    down the scale network, adding

    significantly to network

    resilience.

    Each scale may even be

    connected to a local

    Department HUB. Where

    connection to the office

    computer is required, each HUB

    may then be connected to thestores Ethernet HUB in the

    wiring closet.

    This HUB provides the

    connection to the back-store

    management PC via Ethernet

    cabling.

    Alternatively, full Category 5

    structured cabling may be

    employed, with every scale

    being directly connected toa single hub system within

    the store.

    A back-up server, providing

    automatic server switching and

    subsequent automated recovery

    of the network, off line-sales

    and synchronisation of PLU

    files, should the main server go

    down, can be assigned. Full

    ethernet connection via

    gateways and subnet is

    supported.

    Within a single store-wide

    Ethernet system, multiple scale

    networks can be configured,

    with each having a unique port

    address.

    In this scenario more than a

    hundred IM series scales can

    linked into the stores Ethernet

    hub, with each Server talking

    independently to its ownnetwork of client scales.

    The IM series range also allows

    host names to be specified for

    a particular scale for use in

    conjunction with DHCP and

    DNS. The host name to be

    programmed can be up to 100

    characters.

    The TCP/IP protocol enables

    simple remote diagnostic toolsfrom head office, such as the

    Ping feature.

    RF Communications

    IM series scales are compatible

    with most common Spread

    Spectrum Radio Frequencysystems.

    This enables the use of RF for

    communication between the

    PC located in the management

    office and the counter scales

    in the store.

    Multiple network configurations

    are possible using either only

    RF or combinations of RF and

    direct cabling communications.

    For further information, see theIM series RF Communications

    Data specification sheet.

    System Resilience

    and Networking

    In both LAN and RF networks,

    the back-up server mirrors the

    main server and automatically

    takes control if the main serverfails. When the communication

    with the server is restored,

    transactions are automatically

    recollected from local mode and

    the totals are regenerated.

    Configurable Network Error

    Alarm An audible alarm warning

    of network errors can be

    disabled in sales mode.

    A flashing message appears

    on the vendor display when

    the scale is experiencing

    communication problems.

    5

  • 8/9/2019 IM Series Counter Service.pdf

    6/14

    IM Series Avery Weigh- Tronix Technical Specification

    Software

    This section defines version 7

    software operation of the IM

    series system scales.

    Operating Modes

    Label Mode

    IM series scales operating in

    label mode are generally used

    for single item, weighed or

    non-weighed transactions.

    In label mode, the system can

    be set to Print on Request

    (press the Print or Operator

    keys) or Immediate (as soon

    as the weight is steady).

    Self-Service Mode

    IM series scales can be set into

    self-service mode where they

    are intended for the general

    public to weigh and label their

    own produce. When in self-

    service mode, IM series scales

    prompt the customer to select

    item from the keyboard, beforeplacing the produce on the scale

    and pressing the print key to

    print the label.

    By setting the scale to print

    immediate, the label can

    automatically be issued after the

    produce is on the scale, without

    having to press the print key.

    Pre-pack

    Pre-pack mode enables anumber of consecutive labels to

    be printed for each selected

    item. For this reason, the

    selected item - along with any

    tare details, are retained until

    cleared.

    In general, an item is selected in

    the standard way and the details

    are automatically fixed - with a

    label being printed each time the

    weight changes and then returns

    to a steady weight again.

    To cancel that item, press the

    clear key until the Enter PLU

    message is displayed.

    Direct entry to Pre-pack mode,

    by pressing the Fix key, can beenabled in system configuration.

    Label Formats

    Label formats can be pre-set for

    a scale or may be set for each

    individual item.

    Up to 12 label formats can be

    set up, with standard default

    formats being pre-set into each

    IM series on delivery. Every

    label format can be modified inService mode, or using label

    format editors in MX050 (the M

    series support tool) or MX4X0

    (retailer management package).

    Up to 50 fields of information

    can be printed on each label

    format.

    Legends such as those for the

    current date, expiry date, price

    per kg and total price values

    may be configured to print

    automatically.

    Sales messages may be set

    against a PLU and printed on

    labels, within sales message

    fields.

    Label lengths can be from 160

    mm to as short as 40 mm and

    may be printed in 0, 90 or 180

    orientation.

    Printing can be set for individual

    thermal labels or to print on

    continuous, sticky paper

    (enabling short and long labels

    to be printed for different

    products).

    Receipt Mode

    Receipt mode enables the

    operator to float up and down

    a counter from one scale to

    another, producing one receiptfor the complete set of

    transactions.

    Up to 20 operators may be live

    on the network at any one time,

    with name and number printing

    on the receipts.

    Each item in the scale isassigned to that operator and

    finally printed by pressing the

    Total key.

    Transaction details printed on

    the receipt include; store header

    details and optional logo,

    operator details, date / time /

    terminal / receipt number,

    number of items, total value

    and any tax elements.

    A barcode may be printed at

    the bottom of each receipt.

    This barcode can contain

    receipt-specific information

    such as total value, receipt

    number or customer number.

    It can be scanned at the point

    of sale in a system network to

    instantly recall transactions,

    thereby saving time and

    increasing customer throughput.

    Individual line details, including

    description, weight or quantity,

    unit price and price to pay are

    also printed.

    Single Item mode may be set

    up which automatically prints

    a full receipt after each item

    transaction is completed.

    The void function enables the

    complete sale or any individualline to be cancelled and the

    voided transactions are

    identified on receipt print outs.

    By including the Department

    or Group in the receipt barcode,

    sales may be limited to items

    from the same set only

    (department interlock feature).

    Sales/management functions

    are protected via operator PINcodes to ensure that only

    authorised operators have

    access to those functions.

    6

  • 8/9/2019 IM Series Counter Service.pdf

    7/14

  • 8/9/2019 IM Series Counter Service.pdf

    8/14

    IM Series Avery Weigh- Tronix Technical Specification

    To maximise efficiency of PLU

    maintenance, the operator may

    configure the actual fields

    displayed to the user during

    PLU maintenance, disabling

    those which are not required(e.g: remove label fields if the

    scale is only to be used in

    receipt operation).

    Label and receipt text can be

    programmed in font sizes

    ranging from 1 to 8 and from

    A to L.

    See IM series Label Printing

    Formats Specification for font

    designs.

    Promotions

    A PLU may be programmed with

    one of the following types of

    promotion:

    Price Promotion:Applicable to

    both weighed and non-weighed

    products and allows a 2nd price

    to be automatically applied

    when either a certain weight or

    number of items of a product

    are sold.

    Weight Free Promotion:

    Applies to weighed products

    only and allows a configurable

    amount of weight to be sold free

    of charge, when the total weight

    of the product is above

    configurable amount of weight.

    Items Free Promotion:Applies

    to non-weighed products only

    and allows a configurablenumber of items to be sold

    free of charge, when the total

    number of items is above a

    configurable number of items.

    Discount Promotion:

    Applicable to both weighed

    and non-weighed products

    and allows a discount value to

    be automatically applied to the

    transaction value when a certain

    weight or number of items

    are sold.

    Frequent Shopper Promotion:

    Applicable to both weighed

    and non-weighed products

    and allows a product to be

    programmed with a second

    fixed price which is thenprinted on the label in addition

    to the original price. Customers

    who are part of a stores

    frequent shopper program, are

    charged at the frequent shopper

    price at the point of sale. The

    barcode printed on the label

    containing a frequent shopper

    promotional price will contain

    the original standard price.

    When a PLU with a promotionis selected, the product

    description on the display

    will flash to indicate this to

    the vendor.

    A promotional message advising

    of the actual promotion can also

    be set against each PLU for

    display and printing purposes.

    All of the above promotions

    except the frequent shopper

    promotion can be used in label

    and receipt modes. Frequent

    shopper can only be used in

    label mode.

    Nutritional Information

    Each PLU can be provided

    with nutritional information if

    required. A list of nutrients

    needs to be programmed first,

    against which, values are then

    programmed in the PLU

    records. Nutrient information

    can be programmed to print

    either on the same product

    label, or on a separate label.

    As well as being able to print

    individual nutrient values per

    product, the standard measure

    (normally 100 g) values and RDA

    values can also be printed.

    Departments

    You can create up to 10

    departments each having a 20

    character description.

    All products are allocated to a

    specific department.

    Messages

    Up to 99 scrolling or flashing

    messages may be programmed,

    of up to 200 characters each.

    You can assign each scale to

    display one of these messages.

    Up to 20 sales messages may

    be programmed, and these can

    be called-in to print on labels,where a field has been set up for

    this purpose.

    Tables

    The following data tables can

    be programmed.

    Tax

    3 tax rates can be programmed,

    with up to two tax rates being

    assigned to PLUs.

    Tares

    Up to 10 tare weights can be

    programmed which can be

    assigned to PLUs for use as

    preset tare values or assigned

    to keys for recall in normal

    operating mode.

    A tare interlock can be used to

    ensure a label is only printed if a

    tare has been selected.

    Tares may be configured as self-

    cancelling (one-shot) or fixed.

    Additionally, semi-self-

    cancelling, cumulative,

    accelerating or proportional

    tares may be programmed.

    8

  • 8/9/2019 IM Series Counter Service.pdf

    9/14

    Avery Weigh- Tronix Technical Specification IM Series

    Payment Tables

    Payment tables includes local

    cash, foreign cash, credit

    card, account, coupon or

    general. A selection of paymenttypes are available by scrolling

    with the arrow keys, entry is

    accepted by pressing the

    enter key.

    Discount Tables

    A maximum of 9 discount rates

    are programmable. A maximum

    of 16 displayed characters may

    be entered for describing the

    discount rate. The discount

    value may be disabled orentered as a percentage or

    value. The security level is

    applied for discount protection

    when operating the scale in

    sales mode.

    Add Label

    You can assign one of the

    standard label formats to be

    printed as the add label format,

    or this can be set to print in a

    receipt style.

    Logos

    Up to 5 different logos may be

    stored and used. Logos are

    loaded into M series scales

    using MX050. A logo report can

    be printed showing all logos

    stored in the scale. The scale

    contains the statutory safe

    handling and nutritional data

    logos required by law in the

    United States of America bydefault.

    Logos can be used for a variety

    of applications including printing

    on labels or receipts as store

    logos, and for promotional

    purposes.

    Barcode Types and Formats

    The M series range is able to

    support the following barcode

    types:

    EAN 13

    EAN 13 Scandinavian.

    EAN 8 - mainly used in Europe

    UPC 13

    UPC12

    EAN 128

    RSS expanded

    RSS stacked

    RSS 14

    RSS limited

    The following data may be

    encoded in the barcode: articlenumber, price, weight, trace

    code, operator number or

    department number, group and

    transaction number. SSCC data

    is also supported.

    Weighing and traceability type

    application identifiers are

    supported by EAN 128 and

    RSS barcode formats.

    Barcodes may be programmedto print on receipts, labels,

    talons or combinations thereof.

    The Add label barcode format is

    that which is programmed for

    that machines receipt.

    Each PLU may be programmed

    to use one of 10 configurable

    barcode formats.

    OperatorsThe multi operator system

    enables a max of 20 live

    operators in a network.

    Floating operator system

    enables each operator to work

    on any scale in a system at any

    time.

    Header Message

    (for Receipts Only)

    The message printed at the top

    of receipts can be programmed

    at any scale and is transmitted

    to all scales in a system,ensuring all machines print

    identical headers.

    The header message has up to

    200 characters of text and may

    be printed multi-line, across the

    full width of the receipt.

    A logo can also be used in

    addition to, or instead of, the

    header message and is printed

    at the top of the receipt.

    Trailer Message

    (for Receipts Only)

    The trailer message printed

    at the bottom of receipts is

    programmed at any scale and

    is transmitted to all scales in a

    system, ensuring all machines

    print identical footers.

    The trailer message has up to

    200 characters of text and may

    be printed multi-line, across the

    full width of the receipt.

    A logo can also be used in

    addition to, or instead of, the

    trailer message and is printed

    at the bottom of the receipt.

    Re-Pricing

    The re-pricing mode is a

    non-PLU associated method of

    printing labels, with pricing and

    barcode information which are

    adhered over a products

    original price and barcode

    information. The re-price

    function requires setting up

    with default label information,

    barcode format, whether packs

    will be weighed and if totals are

    required to be stored or not.

    9

  • 8/9/2019 IM Series Counter Service.pdf

    10/14

    IM Series Avery Weigh- Tronix Technical Specification

    Traceability

    IM series scales feature

    comprehensive options for

    all types of traceability

    requirements. Up to threedifferent traceability schemes

    may be individually

    programmed, allowing

    associated products to be

    tracked through their supply

    chains. Scheme options include

    the ability to print user-defined

    trace information, manual or

    scannable methods of data

    input and the ability to

    reproduce traceability

    passports. All schemes can be

    used in either label or receiptmodes, allowing counter or

    pre-pack service operation.

    Security Levels

    Programming Security Levels

    for Management Functions

    The system has 3 security

    levels: 0 - no security up to

    2 - highest level.

    Functions assigned to securitylevel of 0 will have no security

    ie: they can be accessed by

    any user.

    Each operator can be given

    security level 0 - 3. Every

    exceptional sales function (e.g.

    Void, Refund) can be set to

    require PIN authentication: level

    0 - 3. If set > 0 for a selected

    function, system prompts for

    the Operator number then the

    PIN code.

    If the Operator security level is

    greater or equal to the function

    level, the transaction will

    proceed, but, if the operator

    security level is less than the

    function level, the scale prompts

    for a supervisor.

    All management functions

    operate on similar security

    levels.

    Security Levels for Operator

    Functions

    Operators are programmed with

    security levels between 0 - 3.

    Operators are allocated

    personal PIN codes that theycan change on a regular basis,

    via a PIN key which may be

    assigned to the keyboard.

    Programming Security Levels

    for Sales Functions

    Security levels of sales functions

    are set up by scrolling through

    the sales functions in

    management mode and

    allocating them with security

    levels 0 - 3. These functionsare initially set up with

    default levels.

    Security Log

    The security log is a report

    which shows functions that

    have been carried out above a

    user-entered security level. For

    example, a report printed for

    security level eight would print

    each level eight and nine

    function was carried out, with

    the date, time and the name

    of the operator who performed

    the function.

    System Functions

    Audit Mode

    Audit mode is either enabled or

    disabled in manager mode.

    Audit mode contains functions

    like filtering, server buffer, client

    buffer, Audit Report and erase

    Audit list.

    The filtering option allows the

    operator to select which printing

    modes transactions should be

    stored, i.e. Label only, Receipt

    only or Label and Receipt

    transactions.

    The server buffer is configurable

    to store receipt or label

    transactions in a linear

    or circular format.

    Linear can only hold adetermined number of

    transactions and advises

    the operator when full.

    A circular buffer will

    continuously write over

    transactions on a first in, first

    out basis when the memory

    becomes full.

    A transaction buffer size can

    be changed in Service mode,

    on installation.

    Receipt Weight Mode

    If required, the total weight

    of each receipts weighed

    transactions can be printed

    at the bottom of the receipt.

    Last Subtotal

    When enabled, last subtotal

    allows operators to recall the

    value and number of

    transactions from the last receipt

    they transacted, to the display.

    Reprinting of the receipt is

    possible by pressing the Total

    key. Note that this receipt is

    marked as a duplicate copy.

    Pre-Pack PLU Lock

    Dependent upon the setting

    of the pre-pack PLU lock, in

    pre-pack mode, PLUs may need

    to be cleared before a different

    PLU can be called via thepre-set keyboard. If they are

    required to be cleared, set as

    enabled. If they are not to

    cleared, set as disabled.

    Security Log Level

    Any functions with a security

    level equal to or higher than

    the value entered here, will

    be printed in the security log.

    10

  • 8/9/2019 IM Series Counter Service.pdf

    11/14

    Avery Weigh- Tronix Technical Specification IM Series

    Summary Receipts

    For networked receipt

    printing machines to work in

    customer,system or receipt

    scan mode, summary receipts

    is required to be set tosubtotal. This results in

    subtotal receipts being

    produced, which can be

    recalled using the customer

    number printed on the receipt,

    at the PoS.

    Customer Number

    This can be set to be manually

    entered or system generated.

    The customer number is only

    printed on summary receipts.

    Machine Data

    Pre-set Key Assignments

    (Dedicated Keys)

    The free-programmable (pre-set)

    keys may be set to any

    combination of functions,

    including PLU, tares,

    Departments or Operators.

    Standard assign; includes PLU,

    Operator, Log, PIN, Tax,

    Department, Tare, Prop. Tare,

    Dual Capacity, Euro, Return,

    Discount, Sub - total and Hash,

    Hand Price Keys, -UP/PLU

    Positive Non-weighed, Negative

    Non-weighed, Carcass, Code,

    Stock, Weight Override,

    Checkout Operator, Customer

    Number and Consecutive

    Number, PLU search.

    ECR assign; consists of up to 5

    payment references, No Sale,

    Float, Pick up, Paid out,

    Received on Account and

    Refund.

    The pre-set keys can be re-titled

    by applying adhesive labels to

    the operators overlay or by re-

    printing the complete keyboard.

    MX050 enables keyboards to be

    designed and printed.

    Function Keys

    The PRINT key can be set to be

    used to print total (non Pos and

    PoS), receipts or subtotal

    (non-itemised) receipts (for

    use in customer, systemor receipt scan modes).

    Data Back-up

    This mode includes the

    following functions :

    System Dump/System Load;

    Includes the transmitting of the

    following data sent to or from ascale or PC running the MX050

    support tool: PLUs, logos,

    carcass tracking data, ADD

    label info, tax rates, stored

    tares, Euro rate and symbol,

    label formats, scroll messages,

    sign-on/off messages, store

    name, operator numbers,

    network ID, departments,

    nutritional information, sales

    messages and discounts.

    Machine Dump/Load; Includes

    the transmitting of the following

    data sent to or from a scale;

    Machine identity, key

    assignments, key set-ups,

    printer set-up, print modes,

    trace code, symbols, custom

    menus, label mode, label type,

    label detect, tare interlock,

    barcode assignments, Euro print

    set-up and display contrast.

    Totals Receive; performs

    a backup file of the totalsinformation produced from

    the scale.

    Reports

    Data Reports

    The following reports may beprinted on receipt paper, for

    data management purposes:

    PLU file list, operators report,

    text report, discount list, security

    level, payment key list, account

    list, promo batch list, carcass

    reports, barcodes, logos, tax

    rates, tare weights, AIs,

    nutrients, batch reports,

    traceability totals, keyboards.

    Any data report can be haltedby pressing the Clear key.

    Sales Reports

    Reports are available on the

    following:

    PLU totals (with option to

    enter a start and end range)

    Operator (optional range)

    Grand totals

    Department (optional range)

    Machine

    Hourly (// hour or hour)

    Group (optional range)

    Discount totals

    Promotion totals

    System cash

    Security

    11

  • 8/9/2019 IM Series Counter Service.pdf

    12/14

    IM Series Avery Weigh- Tronix Technical Specification

    Carcass (lists an audit trail of

    the last 100 carcasses used,

    showing the total weight

    packed, the value and the last

    date on which that carcass

    was used)

    Single (X/Z) report periods,

    enable daily plus weekly

    reporting.

    Totals Batching

    All of the above totals reports

    from any period may be batched

    together to allow up to nine

    different reports to be printed at

    the press of a button. Up to five

    batches may be programmed,which are then assigned to a

    key on the keyboard.

    Audit Reports

    Audit reports print out

    transactions which have been

    totalised and printed on the

    label or receipt during sales

    transactions.

    On networks operating in

    customer or system mode this

    is the PoS receipt. Transactions

    are printed either from the last

    clearing date or from the

    date/time specified by the

    operator.

    The operator may clear the audit

    transactions at the end of the

    printout. The operator may

    choose between a full or

    summary report.

    Audit reports may be configured

    to be printed out as a summary

    or in detail, selected by time,

    receipt number or filter for

    transaction type.

    The summary report shows the

    total value and number of

    transactions for each receipt

    and the grand totals.

    It is possible to clear or print

    outstanding transactions (e.g:

    unreconciled receipts at the end

    of the day) or clear all totals

    (normally only when a system

    is being set up to go live).

    Service Mode

    This mode includes the

    following functions, accessible

    by entering the service PIN

    number during the power-on

    countdown:

    Diagnostics, Configuration,

    Country Config., Calibration,Site Gravity, Manager PIN,

    Service PIN, Euro Set-up, Clone

    Machine and Label Editor.

    PC Based Systems

    Software

    Management

    Packages

    Brief overview of the PCapplications available for

    support or retailer use.

    MX100

    MX100 has been specifically

    designed to provide a

    transparent interface between

    the retailers primary Store

    Management module (generally

    the EPoS system), and themixture of scales in the various

    departments within the store.

    MX100 is designed to run on the

    same computer as the

    management module, but in

    the background.

    This solution allows the retailer

    to control the prices and

    product range in both the EPoS

    and the scale systems from theHead Office.

    MX100 also provides for the

    collection and return of scale

    sales reports, as well as

    enabling a detailed audit

    trail of transactions.

    How does MX100 work

    - The MX100 is installed on

    the local store management

    system.

    - MX100 processes the

    incoming product change

    file and validates its integrity.

    - The validated file is

    communicated to the scales

    via the driver.

    MX400

    MX400 is a dedicated scale

    management system, providing

    functions not generally found in

    retail business management

    software (such as extended text

    editing and label design).

    It provides a safe and securemethod of maintaining scale

    data and recovering trading

    information. Used for the

    following applications:

    - In store scale Management

    system

    - Support for WA and WS

    wrappers, IM, M and MP series

    - Management of product data

    - Configuration of scales

    - Historical Reporting on totals

    12

  • 8/9/2019 IM Series Counter Service.pdf

    13/14

    Avery Weigh- Tronix Technical Specification IM Series

    13

    System Support

    Application: MX050

    The MX050 software programme

    enables authorised staff toretrieve, edit and store and

    return label formats, amend text,

    create keyboards and transmit

    logos and other data files to

    and from scales.

    MX050 can also provide

    diagnostic and remote control

    of distant M and IM series

    installations.

    Remote MX050 operation ispossible via modem or ethernet.

    See MX050 specification sheet

    for more information.

    Kits

    The following kits are also

    available for the IM series range:

    All Models:

    C924000000AB0000-

    Low profile stainless steel cashdrawer

    AWT05-053028-

    Economy Cash Drawer

    AWT05-052964-MS9520

    Metrologic Voyager USB

    Hand Scanner

    AWT05-052965-MS3780

    Metrologic Fusion USB Handheld

    omnidirectional scanner

    AWT05-052966-MS7120

    Metrologic Orbit Presentation

    scanner

    IX1001AE00000000-

    G Pan Kit

    IX1001AF00000000-

    12 IN L2 Scoop Kit

    IX1001AG00000000-

    16 IN L2 Scoop Kit

    IX1001AH00000000-

    Scoop Cradle Kit

    AWT05-05313-

    IM RF KIT D Link

    AWT05-053032

    IM RF Kit - No D Link

    AWT05-053013-IM RF Kit - D Link for IM500 only

    AWT15-000102-

    IM RFKit -NoD Link for IM500 only

    AWT15-000054-

    Circular pan kit

    AWT15000092-

    Telescopic pole kit

    Other Information

    Paper Type

    For a full description of the label

    material specification to be used

    with the IM series, please refer

    to the Thermal Label/Receipt

    Material Specification for IM

    series.

    Electrical

    Requirements

    Mains Supply

    Single phase, AC.

    Europe: 220 V - 240 V

    (-15% + 10%) at 50 Hz

    or 60 Hz.

    USA: 110 V - 120 V at 50 Hz

    (-15% +10%).

    Approximate Consumption

    160 VA (when printing).

    18 VA (when not printing)

    Supplied with two metres, three-

    core mains cable with moulded

    power adapter.

    Mains ON-OFF switch on scale,

    accessible by the operator.

    Safety Standards

    The IM series range fully

    complies with CE requirements,

    including EMC directives in BS

    EN60950.

    The USA safety standard is

    UL 1950 and Canada CAN22.2

    950.M99.

    Housing and

    Environment

    IM series models share the

    following exterior appearance:

    - A wipe clean, textured gloss

    surface, designed to provide

    easy peel-off of labels.

    - High UV resistance for good

    colour stability.

    Operating Environment

    Resistant to dust abrasive

    environment.

    Resistant to salt water.

    Resistant to blood and

    animal fats.

    Operating Temperature Range:

    -10 C to +40 C.

    Storage Temperature Range:

    -30 C to +70 C.

    Humidity

    10% to 98% RH.

    Weights

    IM 100 = 6 kg

    IM 202 = 7.4 kg

    IM 300 = 12.2kg (including

    single keyboard)

    = 15kg (including double

    keyboard)

    IM 400 = 8.2 kg

    IM 500 = 13.5 kg (including

    hanger and pan)

  • 8/9/2019 IM Series Counter Service.pdf

    14/14

    IM Series Avery Weigh- Tronix Technical Specification

    Foundry Lane, Smethwick,

    West Midlands, England B66 2LP

    Tel: +44 (0)870 90 34343 Fax: +44 (0)121-224 8183

    Email: [email protected]

    Internet: http://www.averyweigh-tronix.com

    Avery Berkel Limited 2007..All rights reserved.This publication is issued to provide outline i nformation only which,unless agreed by Avery Berkel Limited in writing,may not be regarded as a representation relatingto

    the products or services concerned.Avery Berkel Limited reserves the right to alter without notice the specification,design,price or conditions of supply of any product or service.

    Your local distributor:

    IM 100

    Net: 14 kg.

    Gross: 17 kg.

    Measurement:

    480 mm x 460 mm x 270mm

    Number of Packages: One

    Harmonised Commodity Code:

    8423181 50 0.

    IM 202

    Net: 16 kg.

    Gross: 21 kg.

    Measurement:

    572mm x 460mm x 585mm

    Number of Packages: One

    Harmonised Commodity Code:

    8423181 50 0.

    IM 300

    Net: 20 kg.

    Gross: 25 kg.

    Measurements:

    480 mm x 460 mm x 270mm

    910 mm x 510 mm x 250 mm

    Number of Packages: Two

    Harmonised Commodity Code:

    8423181 50 0.

    IM 400

    Net: 16 kg.

    Gross: 21 kg.

    Measurement:

    495mm x 460mm x 585mm

    Number of Packages: One

    Harmonised Commodity Code:

    8423181 50 0.

    IM 500

    Net: 18 kg.

    Gross: 23 kg.

    Measurement:

    600 mm x 475 mm x 675 mm

    Number of Packages: One

    Harmonised Commodity Code:

    8423181 50 0.

    Shipping Specification

    303 374

    407 374

    215

    234 270.5

    169 Min

    181 Max

    195

    396

    84

    303

    496

    374

    234270.5

    245

    245

    121

    195

    444

    131

    169 Min

    181 Max

    396

    157

    303

    346 374

    52.4234

    33 275

    260

    244

    117

    140

    169 Min

    181 Max

    Dimensions

    IM100 IM202

    IM400

    372 156

    310

    344

    398

    743

    93

    398

    IM500

    374

    361

    294

    428

    270.5

    195

    303

    67

    407

    234

    215

    85

    19

    169 Min

    181 Max

    IM300


Recommended