Enjoy multiple choices for indoor units. With this year's new additions to the product line, there will
be more variety in options to fit the needs of the modern building environment. The interior mechanical
components are designed for ultimate comfort and functionality and the aesthetic side of the air
conditioner will make the already well made product even better. Meet this year's new indoor units in style.
01Indoor Units
Indoor Units _ 12 132008 SAMSUNG Ceiling Air Conditioners
Cassette Type
> Slim 1Way Cassette
> 4Way Cassette
> Mini 4Way Cassette
> 2Way Cassette
Duct Type
> Slim Duct
> MSP Duct
Floor & Convertible Type
> Console
> Ceiling
14
16
20
26
28
30
32
36
42
44
48
imagineindoor units in style
imagine natu ra l coo lness
Indoor Units _ 14 152008 SAMSUNG Ceiling Air Conditioners
600(mm) 650
Lift-up Range
700 750
750mm
700mm
Wide BladeThe new cassette type air conditioner is equipped with uniquely
designed blades that are wider to provide even cooling power
throughout the room.
Air flow is directed towardsthe ceiling which cause ceilingsoiling.
Air flow is directed downwardswithout having contact with theceiling.
Cassette type Icon
High Lift-up Drain PumpThe lift-up drain pump lifts condensed water up to 750mm,compared to the competitor’s 700mm, allowing for flexibleand convenient installation.
Fresh Air IntakeWith optional installation of an air intake motor, fresh air canenter through the cassette unit so you have fresher air in theroom.
Sub DuctThe Sub Duct lets you use the same air conditioner unit tocool another smaller space nearby. (The cassette unit is fitted with a knock-out component to accommodate this.)
Quick Connection of Drain PipeSamsung's unique drain pipe prevents leaks and is easier toinstall with no need to use tape or adhesives.
WIDEWIDEWIDEWIDE FRESHFRESHFRESHFRESH
SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
HIGHHIGHHIGHHIGH
Ceiling Soiling Prevention
Newly designed panel will control the air direction to avoid having contact
with the ceiling. This new design will prevent the ceiling soiling and keep your
interior cleaner than ever, even after long period of operation.Company A
Conventional Blade
Ceiling
Fresh air
Office Fitting room
Motor
Ceiling
New Blade
Samsung
Powerful air flow
The wider blade allows more cooling air to enter the room, which
cools the room faster and extends cooling capacity. Now, you
can be more comfortable even in the corner.
Cassette typeAir conditionersThis year's new cassette type air conditioner still boasts its
slim and compact size, but is now equipped with more
advanced features. The cassette type air conditioner not only
has stronger air flow to cool and heat every inch of space
efficiently, but is also designed to be quiet and to purify.
Expect more with Samsung.
WIDE BLADE
FRESH AIR
INTAKESUB DUCT
QUICK CONNECTION
OF DRAIN PIPE
CEILING SOILING
PREVENTION
HIGH LIFT-UP
DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH
FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
64mm
46mm
WIDER
Slim 1Way Cassette
Indoor Units _ 16 172008 SAMSUNG Ceiling Air Conditioners
MR-AH01MWR-TH01
Individual
Controllers
Panel
MR-BH01 PSSMAMWR-WS00
Accessories
Stylish & Compact
WIDE BLADEQUICK CONNECTION
OF DRAIN PIPECEILING SOILING
PREVENTION
HIGH LIFT-UP
DRAIN PUMP
Cassette type> > > >
Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.
Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit, causingleakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drainpump to prevent water from flowing backward.
Slim and Compact Design
Slim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way
cassette type air conditioner is the answer.
26dB
35dB
33dB
43dB
Low
High
Fan speed Noise level
10.5kg
17kg
38% Down
4kW R410A model Weight
Only 135mm thick
Samsung introduces the world's slimmest indoor
air conditioner unit. Only 135mm thick, the Slim
1Way cassette air conditioner can be installed
practically anywhere.
Lighter indoor unit
The first to apply ABS cabinets into its indoor
units, Samsung has achieved the lightest units
on the market. Its slim lightweight design makes
installation and maintenance a breeze.
135mm
WIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
Check Valve
Ensure that there is sufficient installation space. Allow at least
170mm for the installation.
NOTE
Min. 170mm
Indoor Units _ 18 192008 SAMSUNG Ceiling Air Conditioners
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling/Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
SH026EAV1UH026EAV1
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Specification | Slim 1Way Cassette
Indoor Unit
Outdoor Unit
Cassette type> > > >
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,500
950/3,300/4,600
245/695/1,120
210/910/1,300
3.74(A)
3.63(A)
1.6/3.3/5.2
1.4/5.3/6.4
6.35(1/4)
9.52(3/8)
1/220-240/50
SH026EAV1
PSSMA
CROSS FLOW FAN
8
970X135X410
1,164X212X478
9.9/13
1,180X25X460
1,250X126X530
3.1/4.5
30/25
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
15
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
SH035EAV1UH035EAV1
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/3,500/4,100
950/4,000/4,750
250/1,140/1,420
210/1,160/1,390
3.07(B)
3.45(B)
1.6/5.3/6.6
1.4/5.5/6.8
6.35(1/4)
9.52(3/8)
1/220-240/50
SH035EAV1
PSSMA
CROSS FLOW FAN
8.5
970X135X410
1,164X212X478
9.9/13
1,180X25X460
1,250X126X530
3.1/4.5
32/27
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
15
4Way Cassette
Indoor Units _ 20 212008 SAMSUNG Ceiling Air Conditioners
Individual
Controllers
Panel
P4SMA
Accessories
Powerful & Silent
New Turbo Fan
Stylish Panel Design
The stylish panel design is not only functional, but adds modern class.
Quiet Operation
Imagine a room of cool calmness. The aerodynamically
designed ‘Turbo Fan' minimizes noise from the
turbulence of blade movement. Therefore noise is
less than conventional models.
Uniform distribution
The new 'Turbo Fan' with wide blades provides
extreme cooling power from 4 separate outlets so
the entire room gets cool faster. Now, every nook
and cranny is comfortable.
Outlet
1
Outlet
2
Outlet
3
Outlet
4
Easy LevelingEach corner portion of the panel is detachable, which gives easier
access to adjust the height, therefore leveling and installation is
much easier and quicker than before.
Compact SizeThe 4way cassette type unit has gotten even slimmer. Now
only 218mm thick (5.2/7.0/9.0kW), 24% slimmer compare to
competitor’s 288mm (9.0kW). It's still the industry leader in
compactness and is even easier to install in tight spaces.
Efficient CoolingSamsung has applied the 3-dimensional blade, which has the world wide patent, to provide equal speed to the cool air and
boost up the air flow to spread further and wider to cover all the corners of the space. With this newly designed blade, every
bit of space will be filled with cool air.
WIDE BLADE
FRESH AIR
INTAKESUB DUCT
QUICK CONNECTION
OF DRAIN PIPE
CEILING SOILING
PREVENTION
HIGH LIFT-UP
DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH
FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
Cassette type> > > >
Conventional 4Way
Conventional 4Way
New 4Way
New 4Way
‘A’ View
‘B’ View
‘C’ View
Detachable corners make installation
and height adjustments much easier.
Air d
istrib
utio
n
Detaching the whole panel took
more time.
218mm
MR-AH01MWR-TH01 MR-BH01MWR-WS00
Air d
istrib
utio
n
Indoor Units _ 22 232008 SAMSUNG Ceiling Air Conditioners
Specification | 4Way Cassette
Cassette type> > > >
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
CH070EAV1UH070EAV1
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB (A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
2,100/7,100/8,200
2,000/8,000/11,300
510/2,030/2,700
510/2,110/3,800
3.5(A)
3.7(A)
2.8/9.3/12.1
2.6/9.6/16.9
6.35(1/4)
15.88(5/8)
1/220-240/50
CH070EAV1
P4SMA
TURBO FAN
17.2
840X218X840
926X280X925
31/35
950X35X950
1,042X103X1,042
7.0/10.3
36/30
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
CH090EAVUH090EAV
2,900/9,400/10,350
2,400/11,000/13,400
700/2,930/3,400
580/3,050/5,500
3.21(A)
3.61(A)
3/13.0/15.0
2.5/13.5/24.5
9.52(3/8)
15.88(5/8)
1/220-240/50
CH090EAV
P4SMA
TURBO FAN
24
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
39/32
DEFAULT
UH090EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,600
75
30
7.5
40
CH105EAVUH105EAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
3/15/16.5
2.6/13.8/25
9.52(3/8)
15.88(5/8)
1/220-240/50
CH105EAV
P4SMA
TURBO FAN
25.7
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,800
75
30
7.5
40
Specification | 4Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB (A)
mm
mm
kg
dB (A)
°C
°C
g
m
m
m
g/m
CH105EAVUH105GAV
3,200/10,500/12,000
2,600/11,200/15,500
700/3,270/3,800
580/3,100/5,600
3.21(A)
3.61(A)
1.3/5.0/6.0
1.1/5.0/8.6
9.52(3/8)
15.88(5/8)
3/380-415/50
CH105EAV
P4SMA
TURBO FAN
22.2/25.7
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
88/93
56
-15~50
-20~24
2,800
75
30
7.5
40
CH140EAVUH140EAV
3,800/14,000/15,400
3,450/16,000/19,500
900/4,650/5,400
750/4,690/6,400
3.01(B)
3.41(B)
4/20/23.5
3.3/20.5/27.5
9.52(3/8)
19.05(3/4)
1/220-240/50
CH140EAV
P4SMA
TURBO FAN
30
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
3,100
75
30
7.5
40
CH140EAVUH140GAV
3,800/14,000/15,400
3,450/16,000/19,500
900/4,650/5,400
750/4,690/6,400
3.01
3.41
1.4/7.2/8.5
1.3/7.3/10.2
9.52(3/8)
19.05(3/4)
3/380-415/50
CH140EAV
P4SMA
TURBO FAN
28/30
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
2,800
75
30
7.5
40
Indoor Unit
Outdoor Unit
Indoor Units _ 24 252008 SAMSUNG Ceiling Air Conditioners
Cassette type> > > >
Specification | 4Way Cassette
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
CH052EAMCUH052EAMC
CH070EAM1CUH070EAM1C
CH094EAMCUH094EAM1C
CH105EAMCUH105EAMC
CH105EAMCUH105GAMC
CH140EAMCUH140GAMC
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
5,400
6,000
1,900
1,950
2.84
3.08
8.5
8.6
6.35(1/4)
12.7(1/2)
1/220-240/50
CH052EAMC
P4SMA
TURBO FAN
14
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
34/29
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
7,000
7,200
2,400
2,350
2.92
3.06
11.0
11.0
6.35(1/4)
15.88(5/8)
1/220-240/50
CH070EAM1C
P4SMA
TURBO FAN
18.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
36/30
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1,023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
9,000
9,500
3,400
3,500
2.65
2.71
15.5
16.0
6.35(1/4)
15.88(5/8)
1/220-240/50
CH094EAMC
P4SMA
TURBO FAN
21.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
39/32
DEFAULT
UH094EAM1C
ROTARY
R410A
880X798X310
1,023X891X413
74/82
55
-5~43
-5~24
1,800
30
15
7.5
50
10,000
10,700
3,830
3,850
2.61
2.78
17.5
17.5
9.52(3/8)
19.05(3/4)
1/220-240/50
CH105EAMC
P4SMA
TURBO FAN
24.5
840X298X840
925X360X925
28/34
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105EAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,600
50
30
7.5
70
10,000
10,700
3,560
3,600
2.81
2.97
6.2
6.3
9.52(3/8)
19.05(3/4)
3/380-415/50
CH105EAMC
P4SMA
TURBO FAN
24.5
840X298X840
925X360X925
28/34
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105GAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,750
50
30
7.5
70
14,000
15,400
5,300
5,900
2.64
2.61
9.2
10.0
9.52(3/8)
19.05(3/4)
3/380-415/50
CH140EAMC
P4SMA
TURBO FAN
29
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140GAMC
SCROLL
R410A
932X1,128X375
1,091X1,286X472
121/136
59
-5~43
-5~24
3,300
50
30
7.5
70
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
CH052EZMCUH052EZM1C
6,800
7,700
2,500
2,500
2.72
3.08
11.5
11.5
9.52/(3/8)
15.88/(5/8)
1/220-240/50
CH052EZMC
P4SMA
TURBO FAN
18.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
34/29
DEFAULT
UH052EZM1C
ROTARY
R22
880X648X310
1,023X744X413
60/67
49
-5~43
-5~24
2,400
30
15
5
20
CH070EZMCUH070EZM1C
6,800
7,700
2,500
2,500
2.72
3.08
11.5
11.5
9.52/(3/8)
15.88/(5/8)
1/220-240/50
CH070EZMC
P4SMA
TURBO FAN
18.5
840X218X840
925X280X925
25/31
950X35X950
1,042X103X1,042
7.0/10.3
36/30
DEFAULT
UH070EZM1C
ROTARY
R22
880X648X310
1,023X744X413
60/67
51
-5~43
-5~24
2,400
30
15
5
20
CH105EZMCUH105GZM1C
9,700
10,500
3,600
3,700
2.69
2.84
6.30
6.50
9.52/(3/8)
19.05/(3/4)
3/380-415/50
CH105EZMC
P4SMA
TURBO FAN
24.5
840X298X840
925X360X925
28/34
950X35X950
1,042X103X1,042
7.0/10.3
40/33
DEFAULT
UH105GZM1C
SCROLL
R22
880X931X320
1,043X411X1062
87/92
56
-5~43
-5~24
2,650
50
30
5
40
CH140EZMCUH140GZM1C
13,500
14,500
4,900
5,300
2.76
2.74
8.20
8.80
9.52/(3/8)
19.05/(3/4)
3/380-415/50
CH140EZMC
P4SMA
TURBO FAN
29
840X298X840
925X360X925
29/35
950X35X950
1,042X103X1,042
7.0/10.3
45/38
DEFAULT
UH140GZM1C
SCROLL
R22
932X1,128X375
1,091X1,286X472
121/136
59
-5~43
-10~24
3,700
50
30
5
50
Mini 4Way CassetteCompact & Efficient
Individual
Controllers
Panel
PMSMA
Accessories
Indoor Units _ 26 272008 SAMSUNG Ceiling Air Conditioners
High Energy EfficiencyNot only is the Mini 4Way cassette air conditioner small and compact, it's energy efficient. Easy operation coupled with
high efficiency provides you with remarkable performance at extremely low cost.
Fan Speed AdjustmentFan speed can be adjusted by ceiling height. With an easy to
use PCB option, air flow can be altered for use in high ceilings.
Ideal Compact SizeThe Mini 4Way cassette air conditioner can be installed in one standard ceiling
tile (600Wx600H) so construction or alterations to the ceiling are unnecessary.
3~3.5m 2.7m
Specification | Mini 4Way Cassette
Cassette type> > > >
High Ceiling
On : Increased fan speed Off : Standard fan speed
Unit : mm
Standard Ceiling
MR-AH01MWR-TH01 MR-BH01MWR-WS00
FRESH AIR
INTAKE
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
TH026EAV1UH026EAV1
TH035EAV1UH035EAV1
TH052EAV1UH052EAV1
TH060EAV1UH060EAV1
Model
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
990/2,600/3,500
980/3,300/4,600
260/730/1,100
240/900/1,400
3.56(A)
3.67(A)
1.6/3.4/5.1
1.5/4.3/6.6
6.35(1/4)
9.52(3/8)
1/220-240/50
TH026EAV1
PMSMA
TURBO FAN
11.0
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
30/25
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
990/3,500/4,200
980/4,000/5,000
260/1,090/1,400
250/1,100/1,400
3.21(A)
3.64(A)
1.6/5.0/6.4
1.5/5.1/6.7
6.35(1/4)
9.52(3/8)
1/220-240/50
TH035EAV1
PMSMA
TURBO FAN
12.0
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
34/27
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
1,600/4,700/6,000
1,300/5,500/9,000
500/1,510/2,200
480/1,660/3,200
3.22(A)
3.53(B)
2.4/7.0/10.0
2.6/8.0/15.0
6.35(1/4)
12.7(1/2)
1/220-240/50
TH052EAV1
PMSMA
TURBO FAN
12.9
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
41/33
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
1,800/5,800/6,500
1,800/7,000/10,000
520/1,930/2,050
470/2,180/3,700
3.01(B)
3.21(A)
2.6/8.8/9.4
2.4/10.0/16.0
6.35(1/4)
15.88(5/8)
1/220-240/50
TH060EAV1
PMSMA
TURBO FAN
13.6
575X260X575
660X310X635
17/20
670X35X670
717X93X717
2.6/4.2
41/33
DEFAULT
UH060EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
2Way CassetteSlim & Compact
Individual
Controllers
Panel
P2SMA
Accessories
Indoor Units _ 28 292008 SAMSUNG Ceiling Air Conditioners
Small Size Big PerformanceThe 2Way cassette air conditioner is now 45% smaller than
competitor’s models, so it's even easier to incorporate into
building design.
Twin Cross Flow FanThe 2Way cassette type unit is perfect fit for long and narrow
rectangular type of space. Twin Cross Flow Fan inside of the
2Way cassette will spread cool and warm air even further and
wider with less noise.
Standard Formula for Easy InstallationThe dimensions of the 2Way cassette air conditioner allows for easy
installation into standard ceiling grids (600Wx600H), so everything just
falls into place.
Specification | 2Way Cassette
600mm
600m
m
230mm
890mm575mm
45%Smaller
305mm
1,180mm600mm
Cross flow fans
Air
Cassette type> > > >
MR-AH01MWR-TH01 MR-BH01MWR-WS00
QUICK CONNECTION
OF DRAIN PIPE
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
GH052EAMGUH052EAMC
GH070EAMGUH070EAM1C
Model
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
5,500
6,000
1,700
1,800
3.24
3.33
7.5
7.9
6.35(1/4)
12.7(1/2)
1/220-240/50
GH052EAMG
P2SMA
CROSS FLOW FAN
14
890X230X575
1,107X299X642
21/25
1,180X20X460
1,259X144X539
3.5/6.2
36/28
DEFAULT
UH052EAMC
ROTARY
R410A
880x648x310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
7,000
7,700
2,350
2,500
2.98
3.08
10.5
11
6.35(1/4)
15.88(5/8)
1/220-240/50
GH070EAMG
P2SMA
CROSS FLOW FAN
14
890X230X575
1,107X299X642
22/26
1,180X20X460
1,259X144X539
3.5/6.2
38/28
DEFAULT
UH070EAM1C
ROTARY
R410A
880x648x310
1,023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
Duct typeAir conditioners
Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, but
suppresses proliferation of molds and bacteria.
The anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air.
You deserve to breathe fresh air everyday. High Lift-up Drain Pump (optional)
The lift-up drain pump lifts condensed water up to 750mm,
compared to the competitor’s 700mm, allowing for flexible and
convenient installation.
Clean Filter System
BACTERIABACTERIABACTERIABACTERIA
HIGHHIGHHIGHHIGH
Easy Filter CleaningAfter 1,000 hours of operation the filter clean indicator
will alert you that the filter should be cleaned. The filter
can be easily removed from the bottom, left, or right of
the unit. (1,000 hours is the default set time, which can
be adjusted to 2,000 hours on the internal PCB.)
Smart Pressure ControlThe Smart Pressure Control System adjusts fan speed according to
external pressure, so the air conditioner always gives you consistent
cooling and heating power regardless of the surrounding environment.
WiredWiredWiredWired Wired Remote ControllerWired remote controller is included for more convenient use of the air
conditioner.
Samsung's new duct type air conditioners offer flexible
installation benefits with its slim, compact size and the option
to set up the air inlet either on the bottom or rear of the unit.
Its Smart Pressure Control System also provides consistent
cool and heat air regardless of the surrounding environment,
and the filtering options give you cleaner, healthier air. With
Samsung technology, enjoy more.
Indoor Units _ 30 312008 SAMSUNG Ceiling Air Conditioners
Duct type Icon
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER
CLEANINGHIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURE
CONTROL
WIRED REMOTE
CONTROLLERWiredWiredWiredWired
E.S.P Control
1 2 3
Air
volu
me
Static pressure (mmAq)
H
H
M
M
L
L
Air volume 1mmAq Air volume 3mmAq
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
EH070EAV1UH070EAV1
EH052EAV1UH052EAV1
EH035EAV1UH035EAV1
Model
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/3,500/4,200
980/4,000/5,200
260/1,150/1,400
210/1,105/1,700
3.04(B)
3.62(A)
1.7/5.3/6.4
1.3/5.1/7.9
6.35(1/4)
9.52(3/8)
1/220-240/50
EH035EAV1
-
SIROCCO FAN
11.0
0/2/4
990X199X600
1,133X333X722
26/31
-
-
-
32/27
MDP-E075SEE
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
1,700/5,000/6,000
1,500/6,000/8,000
420/1,550/1,950
360/1,650/2,700
3.23(A)
3.64(A)
2.5/7.0/8.5
2.1/7.5/12.0
6.35(1/4)
12.7(1/2)
1/220-240/50
EH052EAV1
-
SIROCCO FAN
16.5
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
33/30
MDP-E075SEE
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
2,200/7,100/8,000
1,900/8,000/11,000
580/2,210/2,650
550/2,150/3,600
3.21(A)
3.62(A)
2.9/10.0/12.0
2.8/10.0/16.5
6.35(1/4)
15.88(5/8)
1/220-240/50
EH070EAV1
-
SIROCCO FAN
19.6
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/61
52
-15~43
-20~24
1,900
50
30
5
30
Individual
Controllers
Drain Pump
MDP-E075SEE / MDP-E075SEE1
Accessories
Indoor Units _ 32 332008 SAMSUNG Ceiling Air Conditioners
Duct type>> > > >
Specification | Slim DuctSlim DuctSlim & Flexible
Slim Design (EH035/052/070)
Only 199mm thick, this slim design makes installation, maintenance,
and repair easy.
Easy to MaintainParts are easily accessible by simply opening the bottom
panel, which reduces time and maintenance costs.
Flexible Installation (EH035/052/070)
The air inlet can be set up on either the bottom or rear
of the unit, so there is more flexibility in installation.
199mm
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER
CLEANING
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURE
CONTROL
Rear side air inlet Bottom side air inlet
Suction DuctSuction Duct
TexTexDiffuser
Diffuser
199mm
220mm
225mm
160 180 200 220210 230
WIRED REMOTE
CONTROLLERWiredWiredWiredWired
MR-AH01MWR-TH01 MR-BH01MWR-WS00
Specification | Slim Duct
Indoor Units _ 34 352008 SAMSUNG Ceiling Air Conditioners
Duct type>> > > >
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
EH070EAM1CUH070EAM1C
EH052EAMCUH052EAMC
5,500
6,300
1,950
2,000
2.82
3.15
9.00
9.00
6.35(1/4)
12.7(1/2)
1/220-240/50
EH052EAMC
-
SIROCCO FAN
14.9
0/2/4
900X199X600
1,124X315X713
26/30
-
-
-
33/30
MDP-E075SEE
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X704X413
59/66
49
-5~43
-5~24
1,800
30
15
7.5
40
6,800
7,500
2,420
2,420
2.81
3.10
11.10
11.10
6.35(1/4)
15.88(5/8)
1/220-240/50
EH070EAM1C
-
SIROCCO FAN
20.5
0/2/4
1,100X199X600
1,330X330X730
30.5/38.5
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1,023X704X413
60/67
51
-5~43
-5~24
1,800
30
15
7.5
40
Indoor Unit
Outdoor Unit
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Indoor Unit
Outdoor Unit
EH070EZMCUH070EZM1C
EH052EZMCUH052EZM1C
7,000
7,700
2,600
2,600
2.69
2.96
12.0
12.0
9.52(3/8)
15.88(5/8)
1/220/50
EH070EZMC
-
SIROCCO FAN
20
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH070EZM1C
ROTARY
R22
880X638X310
1,023X744X413
60/67
51
-5~43
-5~24
2,250
30
15
5
40
7,000
7,700
2,600
2,600
2.69
2.96
12.0
12.0
9.52(3/8)
15.88(5/8)
1/220/50
EH052EZMC
-
SIROCCO FAN
20
0/2/4
1,100X199X600
1,330X330X730
31/39
-
-
-
36/32
MDP-E075SEE
DEFAULT
UH052EZM1C
ROTARY
R22
880X638X310
1,023X744X413
60/67
51
-5~43
-5~24
2,250
30
15
5
40
Individual
Controllers Accessories
Indoor Units _ 36 372008 SAMSUNG Ceiling Air Conditioners
Specification | MSP Duct Inverter-R
Duct type>> > > >
Drain Pump
MDP-M075SGU1 / MDP-M075SGU2 / MDP-M075SGU3
MSP DuctFlexible & Silent
Easy to MaintainReduce time and maintenance costs by keeping parts easily
accessible.
Flexible InstallationSamsung's MSP Duct air conditioners offer different solutions
for any shape room allowing for specific air flow requirements.
L-shaped area Y-shaped areaAreas far apart
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER
CLEANING
HIGH LIFT-UP
DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURE
CONTROL
Silent Operation with the static pressure controlThe external static pressure control ensures flexible ducts to ensure efficiency and silent operation.
Narrow Width (DH052/070EAS) Middle Static Pressure
900mmSlim Duct
mmAq
2
4
6
8
10
15
MSP Duct
12
4m
mA
q
15
mm
Aq
WIRED REMOTE
CONTROLLERWiredWiredWiredWired
MR-AH01MWR-TH01 MR-BH01MWR-WS00
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
❊ Width measured without control box
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
DH105EASUH105EAS
DH070EASUH070EAS
DH052EASUH052EAS
1,600/5,000/6,000
1,500/6,000/9,000
540/1,550/1,950
500/1,750/3,000
3.23(A)
3.43(B)
2.7/7.1/8.7
2.5/8.0/13.5
6.35(1/4)
12.70(1/2)
1/220-240/50
DH052EAS
-
SIROCCO FAN
16.5
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
-
37/33
MDP-M075SGU3
DEFAULT
UH052EAS
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-10~43
-15~24
1,350
30
20
5
20
2,200/7,100/8,000
1,900/8,000/10,500
700/2,720/3,070
620/2,490/3,670
2.81(C)
3.21(C)
3.1/12.4/13.7
2.71/11.4/16.3
6.35(1/4)
15.88(5/8)
1/220-240/50
DH070EAS
-
SIROCCO FAN
21
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
38/34
MDP-M075SGU3
DEFAULT
UH070EAS
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
52
-10~43
-15~24
1,350
30
20
5
30
3,200/10,500/12,000
2,000/11,200/15,500
830/3,720/4,210
740/3,720/6,600
2.82(C)
3.01(D)
3.6/16.5/18.5
3.2/16.5/29.0
9.52(3/8)
15.88(5/8)
1/220-240/50
DH105EAS
-
SIROCCO FAN
24
0/6/8
1,150X260X480
1,396X363X584
34/40
-
-
-
40/33
MDP-M075SGU1
DEFAULT
UH105EAS
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
121/136
56
-15~50
-20~24
2,600
75
30
7.5
40
Outdoor Unit
Indoor Unit
Indoor Units _ 38 392008 SAMSUNG Ceiling Air Conditioners
Duct type>> > > >
Specification | MSP Duct
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
DH090EAVUH090EAV
DH070EAV1UH070EAV1
DH052EAV1UH052EAV1
1,700/5,000/6,000
1,700/6,000/8,300
550/1,560/1,950
480/1,760/2,750
3.21(A)
3.41(B)
3.1/7.5/9.3
2.6/8.4/13.1
6.35(1/4)
12.7(1/2)
1/220-240/50
DH052EAV1
-
SIROCCO FAN
16.5
0/4/6
900X260X480
1,146X363X584
29.5/34.5
-
-
-
37/33
MDP-M075SGU3
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/53
49
-15~43
-20~24
1,450
50
30
5
30
2,200/7,100/8,000
1,900/8,000/11,000
580/2,210/2,650
550/2,150/3,600
3.21(A)
3.72(A)
2.9/10.0/12.0
2.8/10.0/16.5
6.35(1/4)
15.88(5/8)
1/220-240/50
DH070EAV1
-
SIROCCO FAN
19.6
0/4/8
1,150X260X480
1,390X345X575
34/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X406
57/61
52
-15~43
-20~24
1,900
50
30
5
30
2,900/9,000/10,000
2,400/9,500/11,400
800/2,800/3,400
700/2,780/5,500
3.21(A)
3.41(B)
3.5/12.4/15.0
3.1/12.3/24.5
9.52(3/8)
15.88(5/8)
1/220-240/50
DH090EAV
-
SIROCCO FAN
24
0/6/8
1,150X260X480
1,396X424X524
33/39
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH090EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,600
75
30
7.5
40
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
DH105EAVUH105EAV
3,350/10,500/12,000
2,600/11,200/15,500
830/3,270/3,700
740/3,100/5,500
3.21A
3.61A
3.6/15/16
3.2/13.5/23.8
9.52(3/8)
15.88(5/8)
1/220-240/50
DH105EAV
-
SIROCCO FAN
28.1
0/8/10
1,150X320X480
1,396X424X524
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
95/110
56
-15~50
-20~24
2,800
75
30
7.5
40
DH105EAVUH105GAV
3,350/10,500/12,000
2,600/11,200/15,500
830/3,270/3,700
740/3,100/5,500
3.21
3.61
1.4/5.0/6.1
1.3/5.0/8.5
9.52(3/8)
15.88(5/8)
3/380-415/50
DH105EAV
-
SIROCCO FAN
27.5/28.1
0/8/12
1,150X320X480
1,396X424X524
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
88/93
56
-15~50
-20~24
2,800
75
30
7.5
40
DH140EAVUH140EAV
3,450/14,000/15,400
3,750/16,000/19,500
1,110/4,650/5,300
1,020/4,430/5,800
3.01B
3.61A
4.8/20/23.4
4.4/19.2/25.2
9.52(3/8)
19.05(3/4)
1/220-240/50
DH140EAV
-
SIROCCO FAN
36.8
0/8/10
1,200X360X650
1,447X425X769
55/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140EAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
3,100
75
30
7.5
40
DH140EAVUH140GAV
3,450/14,000/15,400
3,750/16,000/19,500
1,110/4,650/5,300
1,020/4,430/5,800
3.01
3.61
1.8/7.4/8.8
1.7/7.0/9.5
9.52(3/8)
19.05(3/4)
3/380-415/50
DH140EAV
-
SIROCCO FAN
35.6/36.8
0/8/12
1,200X360X650
1,447X425X769
55/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140GAV
TWIN BLDC
R410A
932X1,128X375
1,091X1,286X472
105/120
59
-15~50
-20~24
2,800
75
30
7.5
40
Indoor Units _ 40 412008 SAMSUNG Ceiling Air Conditioners
Duct type>> > > >
Specification | MSP Duct
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
DH094EAMCUH094EAM1C
8,800
9,500
3,650
3,500
2.41
2.71
16.5
15.5
9.52(3/8)
15.88(5/8)
1/220-240/50
DH094EAMC
-
SIROCCO FAN
24.4
0/6/8
1,150X320X480
1,390X345X575
34.5/40
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH094EAM1C
ROTARY
R410A
880X798X310
1,023X891X413
74/82
55
-5~43
-5~24
1,800
30
15
7.5
40
DH105EAMCUH105EAMC
10,000
11,000
3,830
3,850
2.61
2.86
17.50
17.50
9.52(3/8)
19.05(3/4)
1/220-240/50
DH105EAMC
-
SIROCCO FAN
30
0/8/10
1,150X320X480
1,396X424X524
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105EAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,600
50
30
7.5
40
DH105EAMCUH105GAMC
10,000
10,700
3,700
3,800
2.70
2.82
6.40
6.50
9.52(3/8)
19.05(3/4)
3/380~415/50
DH105EAMC
-
SIROCCO FAN
30
0/8/10
1,150X320X480
1,396X424X524
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105GAMC
SCROLL
R410A
880X931X320
1,043X411X1,062
87/92
56
-5~43
-5~24
2,750
50
30
7.5
40
DH140EAMCUH140GAMC
14,700
16,000
5,500
5,700
2.67
2.81
9.50
10.20
9.52(3/8)
19.05(3/4)
3/380~415/50
DH140EAMC
-
SIROCCO FAN
38
0/8/15
1,200X360X650
1,447X425X769
52/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140GAMC
SCROLL
R410A
932X1,128X375
1,091X1,286X472
121/136
59
-5 ~ 43
-5 ~ 24
3,300
50
30
7.5
40
DH175GZMUH175GZMC
DH140GZMUH140GZM1C
DH105GZMUH105GZM1C
10,000
11,000
3,900
3,900
2.6
2.82
6.7
6.95
9.52(3/8)
19.05(3/4)
3/380/50
DH105GZM
-
SIROCCO FAN
29
0/8/10
1,150X320X424
1,396X584X480
39/46
-
-
-
39/35
MDP-M075SGU1
DEFAULT
UH105GZM1C
SCROLL
R22
880X931X320
1,043X411X1,062
88/93
56
-5~43
-5~24
2,650
50
30
5
40
14,000
16,000
5,000
5,000
2.8
3.2
8.6
8.6
9.52(3/8)
19.05(3/4)
3/380/50
DH140GZM
-
SIROCCO FAN
40
0/8/15
1,200X360X650
1,447X425X769
52/60
-
-
-
43/38
MDP-M075SGU2
DEFAULT
UH140GZM1C
SCROLL
R22
932X1,128X375
1,091X1,286X472
105/120
59
-5~43
-5~24
3,700
50
30
5
50
16,700
17,880
5,700
5,200
2.93
3.44
9.4
8.8
9.52(3/8)
19.05(3/4)
3/380/50
DH175GZM
-
SIROCCO FAN
45
0/8/15
1,200X360X650
1,447X425X769
57/64
-
-
-
45/40
MDP-M075SGU2
DEFAULT
UH175GZMC
SCROLL
R22
932X1,128X375
1,091X1,286X472
105/120
62
-5~43
-5~24
3,600
50
30
5
50
Indoor Units _ 42 432008 SAMSUNG Ceiling Air Conditioners
Samsung introduces a new elegance in air conditioners.
This year's new console and ceiling type air conditioners
have the style to complement any decor. The flexibility of
drain pipe placement also gives you more options in where
you want to place the air conditioner. Staying cool has never
been more stylish.
Floor & Convertible typeAir conditioners
Auto ChangeoverThe Auto Changeover automatically selects the operation
mode according to the temperature setting.
I Interior DesignNow with more flexibility in placement, the air conditioner
can add a stylish element to your room.
INTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN
Light Weight UnitThis extremely lightweight design makes maintenance
and installation easy.
LIGHTLIGHTLIGHTLIGHT
Flexible Pipe InstallationThe drain pipe can be installed in 6 different places, so you
have more options in where to place your air conditioner.
Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
AUTOAUTOAUTOAUTO
Floor & Convertible type Icon
INTERIOR
DESIGNINTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT
UNIT
LIGHTLIGHTLIGHTLIGHT
SILENT
MODE
AUTO
CHANGEOVERAUTOAUTOAUTOAUTO
FLEXIBLE PIPE
INSTALLATIONFlexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
WIRELESS REMOTE
CONTROLLERWirelessWirelessWirelessWireless
Silent ModeIndoor units operate quietly with the least possible noise.
Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, but
suppresses proliferation of molds and bacteria.
BACTERIABACTERIABACTERIABACTERIA
Auto
Changeover
Indoor Units _ 44 452008 SAMSUNG Ceiling Air Conditioners
Floor & Convertible type>> > >
Console
Individual
Controllers Accessories
Slim & Elegant
INTERIOR
DESIGNINTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT
UNIT
LIGHTLIGHTLIGHTLIGHT
SILENT MODEAUTO
CHANGEOVERAUTOAUTOAUTOAUTO
FLEXIBLE PIPE
INSTALLATIONFlexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
Elegant Design
Clean Panel
Stay clean with the smartly designed Clean Panel.
This unique panel keeps dust from accumulating so
the unit and the room stays cleaner.
Slim Design
It can't get any slimmer. This newly introduced console
type air conditioner is only 199mm thick, the slimmest
on the market. Its slim
design easily integrates the
unit into your decor.
Silent Operation (23dB)
The silent, yet powerful and efficient cooling and heating system keeps things more
comfortable. Silent mode is available in 4 different operation modes: High / Medium /
Low / Silence.
MPI ZoneSamsung's Micro Plasma Ion Zone is a technology that generates activated
hydrogen and oxygen ions, which exterminates viruses and allergy-causing
microbes in the air by neutralizing them and turning into water.
Slim & Smart DesignThis extremely slim design with Clean Panel adds aesthetic value to any interior.
199mm
Black Display
Functional art, the touch screen display is elegant while
it maximizes the convenience of control.
MR-BH01MWR-WS00MWR-TH01
WIRELESS REMOTE
CONTROLLERWirelessWirelessWirelessWireless
2Way air outletsThere are two separate air outlets for cooling and heating. Having warmer air coming
out from the bottom part of the air outlet will spread the warm air evenly throughout the
room. Stay cooler and warmer in every corner of your room.
Indoor Units _ 46 472008 SAMSUNG Ceiling Air Conditioners
Floor & Convertible type>> > >
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter (Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling/Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
JH026EAV1UH026EAV1
Model
Specification | Console
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,500
950/3,500/4,700
240/650/1,050
220/890/1,300
4.00
3.93
1.6/3.3/5.0
1.4/4.4/6.3
6.35(1/4)
9.52(3/8)
1/220~240/50
JH026EAV1
-
TURBO FAN
8.1
720X620X199
810X710X295
14.5/18.5
-
-
-
38/23
DEFAULT
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter (Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling/Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
JH035EAV1UH035EAV1
Model
Specification | Console
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
990/3,500/4,200
990/4,500/5,000
270/1,020/1,350
240/1,240/1,350
3.43
3.63
2.0/4.9/6.2
1.6/6.0/6.6
6.35(1/4)
9.52(3/8)
1/220~240/50
JH035EAV1
-
TURBO FAN
9
720X620X199
810X710X295
14.5/18.5
-
-
-
39/24
DEFAULT
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
Notes❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter (Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
FH052EAV1UH052EAV1
FH070EAV1UH070EAV1
FH052EAMCUH052EAMC
FH070EAM1CUH070EAM1C
Model
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
1,700/5,000/5,600
1,700/6,000/8,000
480/1,660/1,900
430/1,870/3,050
3.01(B)
3.21(C)
2.8/7.8/9.0
2.4/8.8/14.5
6.35(1/4)
12.7(1/2)
1/220-240/50
FH052EAV1
-
SIROCCO FAN
14.5
1,000X200X650
1,074X294X726
22/26
-
-
-
38/32
DEFAULT
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/54
49
-15~43
-20~24
1,450
50
30
5
30
2,000/7,100/8,000
2,000/8,000/10,500
610/2,520/2,900
580/2,840/3,700
2.81(C)
2.81(E)
3.0/11.0/13.0
2.9/12.5/17.0
6.35(1/4)
15.88(5/8)
1/220-240/50
FH070EAV1
-
SIROCCO FAN
16.0
1,000X200X650
1,074X294X726
22/26
-
-
-
41/36
DEFAULT
UH070EAV1
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/63
52
-15~43
-20~24
1,900
50
30
5
30
5,400
6,200
1,920
2,000
2.81
3.10
8.5
8.6
6.35(1/4)
12.7(1/2)
1/220-240/50
FH052EAMC
-
SIROCCO FAN
13.2
1,000X200X650
1,074X294X726
22/26
-
-
-
38/32
DEFAULT
UH052EAMC
ROTARY
R410A
880X648X310
1,023X744X413
59/66
49
-5~43
-5~24
1,500
30
15
7.5
25
6,700
7,200
2,480
2,550
2.70
2.82
11.4
11.5
6.35(1/4)
15.88(5/8)
1/220-240/50
FH070EAM1C
-
SIROCCO FAN
14.4
1,000X200X650
1,074X294X726
22/26
-
-
-
41/36
DEFAULT
UH070EAM1C
ROTARY
R410A
880X648X310
1023X744X413
60/67
51
-5~43
-5~24
1,700
30
15
7.5
40
200%
100%
136%
118% 123%
100%
Size
24K Btu/h Model
Weight
Smaller Lighter
CeilingSlim & Compact
MR-AH01MWR-TH01
Individual
Controllers
MR-BH01
Accessories
Indoor Units _ 48 492008 SAMSUNG Ceiling Air Conditioners
Compact but PowerfulSamsung’s ceiling type air conditioner boasts a slim, compact
design, half the size of its competitors, with cooling power
comparable to its larger competitors.
2way InstallationDepending on the space availability and the purpose
of the air conditioner, the indoor unit can be installed
under the ceiling or on the floor.
Specification | Ceiling
Under Ceiling Floor Standing
INTERIOR
DESIGNINTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN
ANTI-BACTERIA
FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT
UNIT
LIGHTLIGHTLIGHTLIGHT
AUTO
CHANGEOVERAUTOAUTOAUTOAUTO
FLEXIBLE PIPE
INSTALLATIONFlexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
Floor & Convertible type>> > >
MWR-WS00
WIRELESS REMOTE
CONTROLLERWirelessWirelessWirelessWireless
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter (Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
FH052EZMCUH052EZM1C
FH070EZMCUH070EZM1C
FH105EZACFH105GZXC
FH140EZACFH140GZXC
FH175EZACFH175GZXC
Model
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Indoor Unit
Outdoor Unit
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
5,400
6,200
2,500
2,650
2.16
2.34
11.0
12.0
9.52(3/8)
15.88(5/8)
1/220-240/50
FH052EZMC
-
SIROCCO FAN
15
1,000X200X650
1,074X294X726
22/26
-
-
-
38/32
DEFAULT
UH052EZM1C
ROTARY
R22
880X648X310
1,023X744X413
60/67
49
-5~43
-5~24
2,400
30
15
5
20
6,500
7,400
2,500
2,650
2.60
2.79
11.0
12.0
9.52(3/8)
15.88(5/8)
1/220-240/50
FH070EZMC
-
SIROCCO FAN
15
1,000X200X650
1,074X294X726
22/26
-
-
-
41/36
DEFAULT
UH070EZM1C
ROTARY
R22
880X648X310
1,023X744X413
60/67
51
-5~43
-5~24
2,400
30
15
5
20
9,730
11,928
3,500
4,000
2.78
2.98
6.5
7.2
12.7(1/2)
19.05(3/4)
3/380~415/50
FH105EZAC
-
SIROCCO FAN
22
1,285X198X660
1,379X296X744
34/42
-
-
-
44/40
DEFAULT
FH105GZXC
SCROLL
R22
990X960X400
1,020X1,015X435
112/127
57
17~45
-7~24
2,600
25
10
5
90
12,896
15,123
4,600
4,200
2.80
3.60
8.4
7.9
12.7(1/2)
19.05(3/4)
3/380~415/50
FH140EZAC
-
SIROCCO FAN
31
1,670X240X680
1,764X329X760
52/62
-
-
-
45/41
DEFAULT
FH140GZXC
SCROLL
R22
990X960X400
1,020X1,015X435
112/127
60
17~45
-7~24
3,100
25
10
5
90
14,215
18,025
4,950
5,050
2.87
3.57
8.4
8.7
12.7(1/2)
19.05(3/4)
3/380~415/50
FH175EZAC
-
SIROCCO FAN
45
1,670X240X680
1,764X329X760
52/62
-
-
-
46/41
DEFAULT
FH175GZXC
SCROLL
R22
940X1,245X400
1,058X1,300X435
114
62
17~45
-7~24
5,000
30
15
5
90
Specification | Ceiling
Indoor Units _ 50 512008 SAMSUNG Ceiling Air Conditioners
Floor & Convertible type>> > >
Accessories
MDP-E075SEE
MDP-E075SEE1
MDP-M075SGU3
MDP-M075SGU1
MDP-M075SGU2
Slim duct
MSP duct
PVC Hose, 2.6kW~7.0kW
New Hose, 10.5kW~14.0kW
5.2kW~7.0kW
9.4kW~12.5kW
14.0kW~17.5kW
Duct Drain Pump
ModelClassification Compatible units Description
P1SMA
PSSMA
P2SMA
PMSMA
P4SMA
Unified Panel
Unified Panel
Unified Panel
Unified Panel
Unified Panel
Multi, DVM unified Panel
Single, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
1Way Cassette
Slim 1Way Cassette
2Way Cassette
Mini 4Way Cassette
4Way Cassette
ModelClassification Compatible units Description
Drain Pump
Panel
❉ The panels above are not applied to Middle East models
MWR-TH01
MWR-WS00
MR-BH01
MR-AH01
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
except Console type
Individual and group control
Individual and group control
Simple schedule control
Simple schedule control
Wired Remote Controller
Wireless Remote Controller
ModelClassification Compatible units Description
Remote Controller
Indoor Units _ 52 532008 SAMSUNG Ceiling Air Conditioners
Samsung is bringing a new tomorrow as
a creative leader. Samsung is introducing
a variety of products equipped with
advanced technologies that generate
new kinds of added value helping to
enrich life and bring greater convenience
to customers. So just imagine what it will
be like to have one of those products
with you.
The best choicefor your satisfaction
> 4way cassette | 54 > Duct | 56 > Ceiling | 58
Indoor Units _ 54 552008 SAMSUNG Ceiling Air Conditioners
Accessories>> > >
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
4Way Cassette | 60Hz
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity
Power Input
E.E.R
Running Current
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
CC24BTVA/UMGCC24BTVX/UMG
CC36BTVA/UMGCC36BTVX/UMG
CC42BTVA/UMGCC42BTVX/UMG
CC48FTVA/UMGCC48FTVX/UMG
Model
Indoor Unit
Outdoor Unit
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
24,000
-
2,700
-
8.89
-
12.5
-
6.35(1/4)
15.88(5/8)
1/220/60
CC24BTVA/UMG
PC095MC3S
TURBO FAN
18
840X218X840
925X280X925
25/31
950X950X35
-
7
40/32
DEFAULT
CC24BTVX/UMG
55A260ITAEM
R22
880X648X310
1,023X891X413
55/60
52
21-54
-
1,500
30
15
5
30
32,000
-
3,200
-
10
-
15
-
9.52(3/8)
15.88(5/8)
1/220/60
CC36BTVA/UMG
PC095MC3S
TURBO FAN
29
840X298X840
925X360X925
29/35
950X950X35
-
7
45/35
DEFAULT
CC36BTVX/UMG
CR34KQ-PFV
R22
880X931X320
1,062X1,043X411
90/95
54
21-54
-
1,800
50
30
5
25
41,000
-
4,300
-
9.53
-
20
-
9.52(3/8)
19.05(3/4)
1/220/60
CC42BTVA/UMG
PC095MC3S
TURBO FAN
29
840X298X840
925X360X925
29/35
950X950X35
-
7
46/36
DEFAULT
CC42BTVX/UMG
CR47KQ-PFV
R22
932X1,128X375
1,091X1,286X472
105/115
55
21-54
-
2,500
50
30
5
30
45,000
-
4,800
-
9.38
-
15.5
-
9.52(3/8)
19.05(3/4)
3/220/60
CC48FTVA/UMG
PC095MC3S
TURBO FAN
29
840X298X840
925X360X925
29/35
950X950X35
-
7
46/36
DEFAULT
CC48FTVX/UMG
CR53KQ-TF5
R22
932X1,128X375
1,091X1,286X472
105/115
57
21-54
-
2,700
50
30
5
35
Cooling Only
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity
Power Input
E.E.R
Running Current
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
CH24BTA/UMGCH24BTX/UMG
CH36BTA1/UMGCH36BTX1/UMG
CH42BTA1/UMGCH42BTX1/UMG
CH48FTA/UMGCH48FTX/UMG
Model
Indoor Unit
Outdoor Unit
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
22,000
24,000
2,600
2,500
8.46
9.60
12
11
6.35(1/4)
15.88(5/8)
1/220/60
CH24BTA/UMG
PC095MC2S
TURBO FAN
23
840X218X840
925X280X925
25/31
950X950X35
-
7
40/32
DEFAULT
CH24BTX/UMG
55A240ITBEN
R22
880X648X310
1,023X891X413
63
52
21~54
-5~24
1,800
30
15
5
15
34,000
37,000
3,900
3,700
8.72
10
19
18
9.52(3/8)
15.88(5/8)
1/220/60
CH36BTA1/UMG
PC095MC2S
TURBO FAN
26
840X298X840
925X360X925
29/35
950X950X35
-
7
45/35
DEFAULT
CH36BTX1/UMG
CR42K6-PFV
R22
880X931X320
1,062X1,043X411
90/95
54
21~54
-5~24
2,200
50
30
5
40
40,000
42,000
4,450
4,450
8.99
9.44
21
21
9.52(3/8)
19.05(3/4)
1/220/60
CH42BTA1/UMG
PC095MC2S
TURBO FAN
29
840X298X840
925X360X925
29/35
950X950X35
-
7
46/36
DEFAULT
CH42BTX1/UMG
CR47KQ-PFV
R22
932X1,128X375
1,091X1,286X472
105/115
55
21~54
-5~24
2,500
50
30
5
40
44,000
46,000
5,300
4,800
8.30
9.58
18
16
9.52(3/8)
19.05(3/4)
3/220/60
CH48FTA/UMG
PC095MC2S
TURBO FAN
31
840X298X840
925X360X925
29/35
950X950X35
-
7
46/36
DEFAULT
CH48FTX/UMG
CR53KQ-TF5
R22
932X1,128X375
1,091X1,286X472
105/115
57
21~54
-5~24
3,200
50
30
5
50
Heat Pump
Indoor Units _ 56 572008 SAMSUNG Ceiling Air Conditioners
Accessories>> > >
Duct | 60Hz Heat PumpCooling Only
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
DC24BTSA/UMGDC24BTSX/UMG
DC18BTSA/UMGDC18BTSX/UMG
17,500
-
2,100
-
8.33
-
10
-
6.35(1/4)
12.7(1/2)
1/220/60
DC18BTSA/UMG
-
SIROCCO FAN
16
0/3/6
1,150X260X480
1,396X363X584
32/38
-
-
-
37/33
N/A
DEFAULT
DC18BTSX/UMG
48D190ITCEH
R22
720X548X265
860X615X365
34/36
53
21~54
-
900
30
15
5
15
22,000
-
2,700
-
8.15
-
13
-
6.35(1/4)
15.88(5/8)
1/220/60
DC24BTSA/UMG
-
SIROCCO FAN
21
0/3/6
1,150X260X480
1,390X345X575
35/41
-
-
-
39
N/A
DEFAULT
DC24BTSX/UMG
55A240ITBEN
R22
790X548X285
926X600X382
39/43
54
21~54
-
1,850
30
15
5
15
27,000
-
3,000
-
9.00
14
3/8"(9.52)
5/8"(15.88)
1/220/60
DC30BTSA/UMG
SIROCCO FAN
22
4/6/8
1,150X260X480
1,390X345X575
35/41
-
-
-
40
N/A
DEFAULT
DC30BTSX/UMG
55A260ITBEM
R22
880X638X310
1,023X744X413
55
54
21~54
1,700
30
15
5
35
40,000
-
4,340
-
9.22
-
21
-
9.52(3/8)
19.05(3/4)
1/220/60
DC42BTSA/UMG
-
SIROCCO FAN
31
4/6/8
1,150X320X480
1,390X405X575
39
-
-
-
43/37
N/A
DEFAULT
DC42BTSX/UMG
CR42K6-PFV
R22
880X931X320
1,062X1,043X411
90/95
55
21~54
-
2,400
50
30
5
20
47,000
-
5,000
-
9.40
-
23
-
9.52(3/8)
19.05(3/4)
1/220/60
DC48BTSA/UMG
-
SIROCCO FAN
35
6/8/10
1,150X320X480
1,390X405X575
39
-
-
-
45/37
N/A
DEFAULT
DC48BTSX/UMG
CR47KQ-PFV
R22
932X1,128X375
1,091X1,286X472
105/115
57
21~54
-
2,600
50
30
5
35
56,000
-
7,300
-
7.67
-
22
-
9.52(3/8)
19.05(3/4)
3/220/60
DC60FTSA/UMG
-
SIROCCO FAN
45
6/8/10
1,200X360X650
1,447X425X769
57
-
-
-
46/38
N/A
DEFAULT
DC60FTSX/UMG
63T550CTAHV
R22
932X1,128X375
1,091X1,286X472
105/115
59
21~54
-
3,000
50
30
5
40
DC30BTSA/UMGDC30BTSX/UMG
33,000
-
3,300
-
10
-
17
-
9.52(3/8)
15.88(5/8)
1/220/60
DC36BTSA/UMG
-
SIROCCO FAN
27
4/6/8
1,150X320X480
1,390X405X575
37
-
-
-
42/36
N/A
DEFAULT
DC36BTSX/UMG
CR34KQ-PFV
R22
880X931X320
1,062X1,043X411
90/95
54
21~54
-
1,800
50
30
5
20
DC36BTSA/UMGDC36BTSX/UMG
DC42BTSA/UMGDC42BTSX/UMG
DC48BTSA/UMGDC48BTSX/UMG
DC60FTSA/UMGDC60FTSX/UMG
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supply
ndoor Unit
Model
Panel
Fan Type
Air Flow Rate
External Static Pressure (Min./Standard/Max.)
Set
Panel
Sound Pressure Level ❊3)
Drain Pump Kit (Option)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
Model
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mmAq
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
Outdoor Unit
Indoor Unit
DH24BTA/UMGDH24BTX/UMG
DH18BTA/UMGDH18BTX/UMG
17,500
20,000
1,950
2,020
8.97
9.90
9.1
9.4
6.35(1/4)
12.7(1/2)
1/220/60
DH18BTA/UMG
-
SIROCCO FAN
16
0/2/4
900X199X600
1,133X333X722
26/30
-
-
-
37/33
MDP-E075SEE
DEFAULT
DH18BTX/UMG
55A200IT1EM
R22
880X638X310
744X638X413
55/60
52
21~54
-5~24
1,450
30
15
5
35
24,000
26,000
2,600
2,500
9.23
10.4
11.4
11.9
9.52(3/8)
15.88(5/8)
1/220/60
DH24BTA/UMG
-
SIROCCO FAN
22
0/2/4
900X199X600
1,133X333X722
31/39
-
-
-
39/35
MDP-E075SEE
DEFAULT
DH24BTX/UMG
55A260ITAEM
R22
880X798X310
1,023X891X413
63/70
53
21~54
-5~24
1,950
30
15
5
40
36,000
37,500
4,100
3,550
8.78
10.56
19.1
17
9.52(3/8)
19.05(3/4)
1/220/60
DH36BTA/UMG
-
SIROCCO FAN
30
0/2/10
1,150X320X480
1,390X405X575
39/46
-
-
-
42/36
MDP-M075SGU1
DEFAULT
DH36BTX/UMG
CR42K6-PFV
R22
880X931X320
1,062X1,043X411
90/95
54
21~54
-5~24
2,200
50
30
5
60
42,000
44,000
4,650
4,500
9.03
9.78
22.1
21.5
9.52(3/8)
19.05(3/4)
1/220/60
DH42BTA/UMG
-
SIROCCO FAN
35
0/2/10
1,150X320X480
1,390X405X575
39/46
-
-
-
43/37
MDP-M075SGU1
DEFAULT
DH42BTX/UMG
CR47KQ-PFV
R22
932X1,128X375
1,091X1,286X472
105/120
55
21~54
-5~24
2,600
50
30
5
40
46,000
52,000
5,300
4,800
8.68
10.83
17.5
16.2
9.52(3/8)
19.05(3/4)
3/220/60
DH48FTA/UMG
-
SIROCCO FAN
37
0/2/15
1,200X360X650
1,447X425X769
57
-
-
-
45/37
MDP-M075SGU2
DEFAULT
DH48FTX/UMG
CR53KQ-TF5
R22
932X1,128X375
1,091X1,286X472
105/120
57
21~54
-5~24
3,000
50
30
5
50
57,000
59,00
6,600
5,600
8.64
10.53
21.5
18.8
9.52(3/8)
19.05(3/4)
3/220/60
DH60FTA/UMG
-
SIROCCO FAN
46
0/2/15
1,200X360X650
1,447X425X769
57
-
-
-
46/38
MDP-M075SGU2
DEFAULT
DH60FTX/UMG
CRNQ-05OO-TF5
R22
932X1,128X375
1,091X1,286X472
105/120
59
21~54
-5~24
4,000
50
30
5
50
DH36BTA/UMGDH36BTX/UMG
DH42BTA/UMGDH42BTX/UMG
DH48FTA/UMGDH48FTX/UMG
DH60FTA/UMGDH60FTX/UMG
Indoor Units _ 58 592008 SAMSUNG Ceiling Air Conditioners
Accessories>> > >
Ceiling | 60Hz
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity
Power Input
E.E.R
Running Current
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
FC18BTVA/UMGFC18BTVX/UMG
Model
Indoor Unit
Outdoor Unit
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
17,000
-
1,900
-
8.95
-
8.8
-
6.35(1/4)
12.7(1/2)
1/220/60
FC18BTVA/UMG
-
SIROCCO FAN
13
1,000X200X650
1,080X230X740
22/26
-
-
-
38/32
DEFAULT
FC18BTVX/UMG
48D190ITBEH
R22
790X548X285
926X600X382
39/43
52
21~54
-
1,150
30
15
5
25
FC24BTVA/UMGFC24BTVX/UMG
23,000
-
2,700
-
8.52
-
12.5
-
6.35(1/4)
15.88(5/8)
1/220/60
FC24BTVA/UMG
-
SIROCCO FAN
15
1,000X200X650
1,080X230X740
22/26
-
-
-
41/36
DEFAULT
FC24BTVX/UMG
55A260ITAEM
R22
880X638X310
1,023X744X413
55/60
53
21~54
-
1,400
30
15
5
35
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Capacity
Power Input
E.E.R
Running Current
Piping Connection
Power Supply
Indoor Unit
Model
Panel
Fan Type
Air Flow Rate
Set
Panel
Sound Pressure Level ❊3)
Indoor Filter
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Cooling / Heating
Cooling ❊1)
Heating ❊2)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
WxHxD
WxHxD
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
Indoor unitOutdoor unit
FH18BTA1/UMGFH18BTX1/UMG
Model
Indoor Unit
Outdoor Unit
Btu/hr
Btu/hr
Watts
Watts
Btu/Wh
Btu/Wh
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m3/min
mm
mm
kg
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
17,000
20,000
1,900
1,900
8.95
10.53
8.8
8.8
6.35(1/4)
12.7(1/2)
1/220/60
FH18BTA1/UMG
-
SIROCCO FAN
15
1,000X200X650
1,080X230X740
22/26
-
-
-
38/32
DEFAULT
FH18BTX1/UMG
48D190ITBEH
R22
880X638X310
1,023X744X413
55/60
52
21~54
-5~24
1,450
30
15
5
35
FH24BTA1/UMGFH24BTX1/UMG
21,500
23,500
2,350
2,300
9.15
10.22
10.6
10.5
6.35(1/4)
15.88(5/8)
1/220/60
FH24BTA1/UMG
-
SIROCCO FAN
15
1,000X200X650
1,080X230X740
22/26
-
-
-
41/36
DEFAULT
FH24BTX1/UMG
55A240ITAEN
R22
880X648X310
1,016X700X410
60/67
53
21~54
-5~24
1,500
30
15
5
40
Cooling Only
Notes
❊1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m❊3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
4) Due to ongoing improvement on products, specifications may change without prior notice.
Heat Pump