LN4™ Series LED Linear Includes: SmartCast ® Technology and 0-10V 1 of 6 LPN00258X0001A0_E INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE TO INSTALL: Cree Accessories (ordered separately): LN-EC- End Cap Kit, #18/5 SJT Cord, Power Feed Canopy Kit, Aircraft Cables LN-CK-0-AC- Inter-row Suspension Kit, Non-Power Feed Canopy Kit, Aircraft Cable ELI-125W- Inverter Emergency Relay - For use with customer supplied generators/inverters • EL-SR-120 - for 120V systems • EL-SR-277 - for 277V systems ROOM SETUP: STEP 1: Install all hanging cables and pre-level using a laser level or appropriate substitute. Having pre-leveled hardware will make installation go fast and smoothly. STEP 2: Starting and ending aircraft cables must be within 18” of the end of the row. STEP 3: Note power feed direction on luminaire. The end of the luminaire without joining plate is the feed end. LEVEL ADJUSTMENTS Level: • If joint is high, loosen both joining plate screws ½ turn each and repeat until straight. • If joint dips low, support joining plate and tighten both joining plate screws ½ turn each. Repeat until straight. Side to Side • If joint pulls right – loosen right joining plate screw ½ turn and tighten left joining plate turn ½ turn. • If joint pulls left - loosen left joining plate screw ½ turn and tighten right joining plate Screw ½ turn. • Repeat until 8ft section is straight when viewed from top. Tilt • Place the center packing cradle on top of the fixture to support a level. • Use the 3/32 hex key to tighten the screw in the bottom of the Y-cable to secure. 1 LUMINAIRE PACKAGING CONTENTS: • Packing cradles – the top right and top left pieces are used as assembly aides. The center top piece is used as a support for a level when adjusting the luminaire. • Luminaire with protective film – do not remove film until luminaires are installed and level. • Power feed canopy - 4.6” • Non-power feed which - 2.1”
Transcript
Page 1: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

LN4™ SeriesLED Linear

Includes: SmartCast® Technology and 0-10V

1 of 6 LPN00258X0001A0_E

INSTALLATION INSTRUCTIONSINSTRUCTIONS D’INSTALLATIONIMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1. DANGER- Risk of shock- Disconnect power before installation.DANGER – Risque de choc – Couper l’alimentation avant l’installation.

2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

TO INSTALL:

Cree Accessories (ordered separately):• LN-EC- End Cap Kit, #18/5 SJT Cord,

Power Feed Canopy Kit, Aircraft Cables

• LN-CK-0-AC- Inter-row Suspension Kit, Non-Power Feed Canopy Kit, Aircraft Cable

• ELI-125W- Inverter

• Emergency Relay - For use with customer supplied generators/inverters

• EL-SR-120 - for 120V systems• EL-SR-277 - for 277V systems

ROOM SETUP:

STEP 1: Install all hanging cables and pre-level using a laser level or appropriate substitute. Having pre-leveled hardware will make installation go fast and smoothly.

STEP 2: Starting and ending aircraft cables must be within 18” of the end of the row.

STEP 3: Note power feed direction on luminaire. The end of the luminaire without joining plate is the feed end.

LEVEL ADJUSTMENTS

Level:• If joint is high, loosen both joining plate screws ½ turn each and

repeat until straight.• If joint dips low, support joining plate and tighten both joining plate

screws ½ turn each. Repeat until straight.

Side to Side• If joint pulls right – loosen right joining plate screw ½ turn and

tighten left joining plate turn ½ turn.• If joint pulls left - loosen left joining plate screw ½ turn and tighten

right joining plate Screw ½ turn.• Repeat until 8ft section is straight when viewed from top.

Tilt• Place the center packing cradle on top of the fixture to support a

level.• Use the 3/32 hex key to tighten the screw in the bottom of the

Y-cable to secure.

1LUMINAIRE PACKAGING CONTENTS:

• Packing cradles – the top right and top left pieces are used as assembly aides. The center top piece is used as a support for a level when adjusting the luminaire.

• Luminaire with protective film – do not remove film until luminaires are installed and level.

• Power feed canopy - 4.6”

• Non-power feed which - 2.1”

Page 2: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

2 of 6 LPN00258X0001A0_E

7

8 9

95" Spacing(Single 8 ft section only or first in Series of 8 ft sections)

96" spacing(Every additional section in series)

8 ft Section and Series Suspension Spacing

NOTE: Maximum 2 units (8 ft) per suspension cable.

Joining Plate

Tighten (2) Screws

5 6

Y-Cable

Suspension Tabs Suspension Tabs

Y-Cable

46.5"2

INDIVIDUAL MOUNTING (KIT SOLD SEPARATELY )

STEP 1: Attach cable supports to ceiling at 46.5” spacing. Adjust all cable supports to require hanging height before proceeding. See Figure 2.

STEP 2:Position the luminaire on two end foam packaging blocks while on the floor or suitable working surface. Insert the suspension tabs into the powered end cap slots. Connect the power end cap from LN-EC as shown in Figure 3. NOTE: Leave protective film in place until after the Luminaire is suspended and leveled.

STEP 3:Loosen joining plate screw using provided Allen wrench to allow nonfeed end cap to assemble. Connect the non-power endcap as shown in Figure 4 to end of luminaire using provided Allen wrench.

STEP 4:Raise luminaire to mounting height while supporting both ends. Attach Y-cable to suspension tabs by inserting paddle from outside to inside of the hanging tab. (See Figure 5). Suspension tabs on non-powered end are located in luminaire body and should be positioned next to the non-powered end cap. See Figure 6.NOTE: Level luminaire per cable support instruction sheet.

STEP 5:Connect wiring from powered endcap to AC power supply per the Electrical Connection section.

STEP 6:Remove protective film on lenses prior to activation. Use soft gloves to prevent fingerprints and scratches.

MULTIPLE LUMINAIRE MOUNTING (KIT SOLD SEPARATELY)

NOTE: These luminaires can be used for continuous row mounting: 12 units (48ft) max at 120 Vac, 34 units (136 ft) max at 277 Vac. CREE Emergency lighting inverter installation: 3 units (12ft) max at 120 Vac or 277 Vac (full output). 12 units (48ft) max at 120 Vac (5% output). 34 units (136ft) max at 277 Vac (5% output).

STEP 1: Attach cable supports with y-cables to ceiling. See Figure 7. Following spacing requirements:

• Starting and ending aircraft cable must be within 18" of end of row.

• First 8 ft section: 95" apart.• Additional 8 ft sections: 96" apart.

Adjust all cable supports to required hanging heights before proceeding.

STEP 2: Loosen joining plate screw and allow joining plate to open fully. Join two 4 ft luminaire sections together by positioning two luminaires end-to-end on top of foam blocks from packaging. Slide luminaires together, the joining plate will hang below. See Figure 8. Tighten the two screws provided in the joining plate to draw the two luminaires firmly together using Allen wrench provided in LN-EC kit. Loosen both screws 1 full turn to set rough level. See Figure 9. NOTE: These screws will be used to adjust the alignment of each luminaire section once suspended.

3 4

Page 3: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

3 of 6 LPN00258X0001A0_E

STEP 3: Attach power endcap from LN-EC kit to end of first luminaire. Power feed direction is from the male contact electrical connector end (opposite of joining plate). See Figure 3.

STEP 4: For Single 8 ft Section Installation: Attach non-power endcap to opposite end of luminaire as shown in Figure 4 and proceed to Step 9 below.

For Continuous Row Installation of 8 ft Sections: proceed to Step 6 below.

STEP 5: Suspend 8 ft luminaire section by attaching the suspension tabs to the already installed y-cables’ hanging hardware.

STEP 6: Join additional 8 ft runs per Step 2, in the multiple mounting section. It is not recommended to install in 4ft section, join two luminaires and install as a unit.

STEP 7: Raise additional 8 ft run, attach to existing run. See Figure 8 (minus foam inserts) and Figure 9. Ensure joining plate screws are

fully tightened. These will be adjusted later. Attach Y-Cable to suspension tabs (See Figure 5 or 6). NOTE: To continue a series installation, repeat Step 6 and 7 to the end of the run. If run is complete, skip to Step 8.

STEP 8: Attach the non-powered endcap to the end of the last luminaire in the series as shown in Figure 10. Secure with two screws present in the joining plate and tighten firmly. See Figure 11.

STEP 9: Align and level each 4 ft section in the installation for a uniform look. First confirm that all of the Y-cables are set at the same height from floor. Then adjust the alignment of each 8 ft section by tightening or loosening the joining plates ( See Figure 9) until the entire series is in line. See Figure 12 - 14.

Level (See Figure 12):• If joint is high, loosen both joining plate

screws ½ turn each and repeat until straight.

• If joint dips low, support joining plate

and tighten both joining plate screws ½ turn each. Repeat until straight.

Side to Side (See Figure 13 on the next page):

• If joint pulls right – loosen right joining plate screw ½ turn and tighten left joining plate turn ½ turn.

• If joint pulls left - loosen left joining plate screw ½ turn and tighten right joining plate Screw ½ turn.

• Repeat until 8ft section is straight, viewing from top.

Tilt (See Figure 14 on the next page):• Place the center packing cradle on top

of the fixture to support a level.• Use the 3/32 hex key to tighten the

screw in the bottom of the Y-cable to secure.

STEP 10: Connect wiring from powered endcap to AC power supply per the Electrical Connection section on page 3. While wearing soft cotton no scratch gloves remove protective film on lenses prior to activation.

WRONG

CORRECT

11

12

Joining Plate Tighten (2) Screws

10

Tighten both joining plate screws and 1/2 turn each. Repeat until level.

Loosen both joining plate screws and 1/2 turn each. Repeat until level.

UP/DOWN ADJUSTMENT (IF NECESSARY)

Page 4: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

4 of 6 LPN00258X0001A0_E

WRONG

CORRECT

WRONG

13

1. Loosen 1/2 Turn

SIDE TO SIDE ADJUSTMENT (IF NECESSARY)

CENTER TOP FOAM

LEVEL

14TILT ADJUSTMENT (IF NECESSARY)

2. Tighten 1/2 Turn3. Repeat as Necessary to Straighten

2. Tighten 1/2 Turn

1. Loosen 1/2 Turn3. Repeat as Necessary to Straighten

Angles Exaggerated in Figure For Illustration Purposes.

Page 5: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

5 of 6 LPN00258X0001A0_E

LN-EL: END CAP KIT INSTALLATION (KIT SOLD SEPARATELY)

T-BAR MOUNT/SURFACE MOUNT

STEP 1: Break T-Bar Clip into 2 sides. If surface mounting, attach plate to surface using appropriate hardware.

STEP 2: Insert square-neck bolt into Side 1 of T-bar clip.

STEP 3: Place Side 1 of the T-bar clip around T-bar. Snap Side 2 into place, securing the clip and bolt to the T-bar. See Figure 15.

STEP 4:Secure T-bar clip to the building structure above with customer supplied wire or other appropriate means.

STEP 5:Secure Cover Plate to T-bar clip with 1/4-20 keps nut. For drop ceiling tile use plastic spacer to offset Cover Plate. When installing Cover Plate, take care to orient ground wire down and conduit knockouts facing up 90° from T-bar. See Figure 16.

STEP 6:Remove one of the knockouts on the Cover Plate.

STEP 7:Cut clearance hole in the ceiling tile to match the hole in the Cover Plate. Make certain that the hole is large enough to clear the power supply connector (customer supplied).

STEP 8:Install ceiling tile.

STEP 9:Bring electrical power into canopy using customer supplied flexible conduit, BX, or Romex and secure to the Cover Plate. Make electrical connections in canopy.

STEP 10:Thread 1/4-20 hex nut onto square neck bolt about half way up the bolt.

STEP 11:Loosen Canopy Collar and slide down cable. Slide Canopy over coupler. See Figure 17.

STEP 12:Tighten coupler onto square neck bolt against 1/4-20 hex nut. See Figure 17.

STEP 13:Trim cable and cord to desired mounting height plus 8 in. Strip cord sheathing back to reveal 6 in of leadwire.

STEP 14:Raise luminaire to mounting height and feed cable toggle clips through suspension tabs. See Figure 18.

LN-CK-0-AC: INTER-ROW SUSPENSION KIT INSTALLATION (KIT SOLD SEPARATELY)

T-BAR MOUNT/SURFACE MOUNT

STEP 1: Insert square-neck bolt into Side 1 of T-bar clip. For surface mount, screw 1/4" hanger bolt (supplied by others) into the ceiling. Attach coupler to hanger bolt with or without 2" canopy.

STEP 2: Place Side 1 of the T-bar clip around T-bar. Snap Side 2 into place, securing the clip and bolt to the T-bar. See Figure 15.

STEP 3:Secure T-bar clip to the building structure above with customer supplied wire or other appropriate means.

STEP 4:Install ceiling tile. If necessary, notch tile to fit over T-bar clip.

STEP 5:Loosen Canopy Collar and slide down cable. Slide canopy over coupler. and secure with collar

STEP 6:Tighten coupler onto square neck bolt and trim cable to desired mounting height plus 8 in.

STEP 7:Raise luminaire to mounting height and feed cable toggle clips through suspension tabs. See Figure 18.

T-Bar Clip (Side 1)

15 16 17

18

1/4-20 Square Neck Bolt

T-Bar Clip (Side 2)

T-Bar

Cover Plate- Remove One Knockout

Drop Ceiling Spacer (If Necessary)

1/4-20 Keps Nut

T-Bar Clip

Ground Wire

Canopy

Collar

Coupler

1/4-20 Hex Nut

Suspension tabs

Page 6: INSTALLATION INSTRUCTIONS IMPORTANT …creecanada.com/wp-content/uploads/2016/05/LN-Series... ·  · 2017-01-23This luminaire must be installed in accordance with the NEC or your

6 of 6 LPN00258X0001A0_E

lighting.cree.com

© 2016 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See www.cree.com/canada for warranty and specifications. Cree® and SmartCast® are registered trademarks, and the Cree logo and LN4™ are trademarks of Cree, Inc.

ELECTRICAL CONNECTIONS

Make the following Electrical Connections:

a. Connect the black luminaire lead to the voltage supply Line position. Line 1 or Hot 1.

b. Connect the white luminaire lead to the neutral supply position or Hot 2.

c. Connect the green ground lead to the green supply positiond. If 0/1-10V Dimming is used, connect the violet lead to the

supply positive dimming lead. If dimming is not being used cap off violet lead. (0-10V LN4™ version only)

e. If 0/1-10V Dimming is used, connect the gray lead to the supply negative dimming lead. If dimming is not being used cap off gray lead. (0-10V LN4™ version only)

f. If EL inverter is being used with dimmed luminaires, connect the gray/purple dimming leads to the EL relay input. (SmartCast® Technology LN4™ version only). If not being used cap off violet and gray leads separately.

LINE 1OR HOT 1

GREEN

LINE-BLACK

GROUND-GREEN

SU

PP

LY W

IRIN

G

LUMINAIRE

DIM (-) GREY

DIM (+) VIOLETVIOLET

GRAY

(DIM

MIN

G O

PT

ION

AL

)

LINE-WHITENEUTRALOR HOT 2

0-10V orEL

LED LUMINAIRE MAINTENANCE

CLEANING INSTRUCTIONS:Regular cleaning of the light LED luminaire is required to keep the LED luminaire operating optimal optical performance.

• Prior to cleaning luminaires, turn power OFF to the luminaire.• Dust luminaire regularly with micro-fiber non- scratching cloth to remove any dust accumulation on the LED source or a cloth dampened only

with water.• Do not use any type of cleaners or stiff brushes on the LED luminaire. Use of solvents or hydrocarbon-based cleaners may cause permanent

damage.• Cleaning intervals to be no more than twelve months for IESNA Clean category environments and more frequently for dirtier conditions.

FCC NOTICE

CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.CAN ICES-003 (A)/NMB-003 (A)


Recommended