Technical Innovation 0 45 Human-centered Design Quality Assurance Sincere and Faithful Integrated Access Controller Installation Manual LED 1 2 3 4 5 6 7 8 9 0 # 3000 ANSON Technology Co., Ltd
Transcript
Page 1: Integrated Access Controller

Technical Innovation

0

45

Human-centered Design

Quality Assurance

Sincere and Faithful

Integrated Access Controller Installation ManualIntegrated Access Controller Installation Manual

LED1 2 3

4 5 6

7 8 9

0 #

3000

ANSON Technology Co., Ltd

Page 2: Integrated Access Controller

Product ConnectionProduct Connection

Installation ManualInstallation Manual

Product ManualProduct Manual

Product MaintenanceProduct Maintenance

Live Safely and Conveniently

Function DebuggingFunction Debugging

Page 3: Integrated Access Controller

ASI-8930ASI-8920

ASI-8910

Anson Integrated Access Control Series: ASI-8910, ASI-8920, ASI-8930

Anson Integrated Access Control is characterized by its elegant design and convenient application and installation, which is especially suitable for office buildings and shops. The device is equipped with built-in reader and can work both as controller and reader.

Anson Integrated Access control should be installed indoor. Please consider water-proof facility in case outdoor application is needed.

For detailed information, please refer to Product Manual and Wiring Diagram. Please make sure installation is correctly completed before turn on the power. When connect any external device, please turn off the power. This manual is only a general instruction and all products mentioned in this manual are Anson products.

Live Safely and Conveniently

Product Manual

Features

Operation Instruction

Notice

Product Series

The exterior design of ASI-8920\8930 is protected and patented in P. R. China.

Page 4: Integrated Access Controller

ASI-8910

117

117

21

Working Voltage:DC9-15VWorking Current:≤70mAUnlock Current: ≤3000mAReading Distance: 3-10cmCard Type: ID card

orking Temperature: -15 ~55Card Capacity: 800pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port(normal open, normal close)

W ℃ ℃

Product Parameters

Product Size

AS

I-89

10

AS

I-89

10

Product Manual

Live Safely and Conveniently

The SideThe Back

The Front

Page 5: Integrated Access Controller

Wire Hole

Fixing Hole

Self-trapping Screw

Rear Cover

Rubber Plug

AS

I-89

10

AS

I-89

10

Installatioin ManualInstallatioin Manual

1. Uncover the back from the bottom 2. Put the back cover against wall and screw tight the bolts

3. Ensure power cable is ready before putthe system on,

4. Screw bolt from bottom

Live Safely and Conveniently

Page 6: Integrated Access Controller

GND +12V COM NO NC GND SW BELL BELL

Door BellExit ButtonEM LockPower

ASI-8910 Interface

GND +12V COM NO NC GND SW BELL BELL

Po

we

r In

terf

ace

ASI-8910 Interface

+12V

GND

Connect with Power

GND +12V COM NO NC GND SW BELL BELL

+12V

GND

V+ V- NOCOM NC

Connect with EM Lock

+-

GND +12V COM NO NC GND SW BELL BELL

+1

2V

GN

D

Connect with Electric Lock

Fail-safe

Fail-secure

AS

I-89

10

AS

I-89

10

Connect with Electric Bolt

GND +12V COM NO NC GND SW BELL BELL

+12V Red

GND Black

SIGNAL

SIGNAL

Door Magnet

+12V

GND

Product Connection Product Connection

ASI-8910 Interface

Po

we

r In

terf

ace

ASI-8910 Interface ASI-8910 Interface

Po

we

r Inte

rface

Power Interface

Electric Bolt

Iron Core Cover Plate

Live Safely and Conveniently

Page 7: Integrated Access Controller

GND +12V COM NO NC GND SW BELL BELL

Connect with Barrier

B

arr

ier

Inte

rfa

ce

(E

lectr

ic L

eve

l Sig

na

l)

Common end

Open

Close

Stop

Connect with Automatic Door

GND +12V COM NO NC GND SW BELL BELL

COM1

COM2

Exit Button

GND +12V COM NO NC GND SW BELL BELLGND +12V COM NO NC GND SW BELL BELL GND +12V COM NO NC GND SW BELL BELL

Connect with Door Bell

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

Active Boorbell

Notice: Definition of product interface should be in accordance with the real product. For any inconsistence, please contact with us..

AS

I-89

10

AS

I-89

10

Product Connection Product Connection

ASI-8910 Interface ASI-8910 Interface

ASI-8910 Interface ASI-8910 Interface A

uto

ma

tic

Do

or

Inte

rfa

ce

(

Sw

itch

Sig

na

l)

Live Safely and Conveniently

The automatic door is open when COM1-COM2 is short circuit.

Page 8: Integrated Access Controller

CARD

Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

3-10CM

As shown in the picture, when the button is pressed, the device sounds once and the relay status changes once.

ASI-8910

Dial *Input the administrator password

MODE light is on, program mode

Dial 2 add one card

Adjust the multimeter to When the power is on, in normal state, COM-NC is short circuit, while COM-NO is open circuit. When present the valid card or press the exit button, COM-NC turns into open circuit.

,

Read cardInput 4-digit card serial number

Dial # to exit from programming mode Complete the setting

GND +12V GND SW COM NO NC BELL BELL

ASI-8910 Interface

A

COMNC

NOCOM

NC

NO

Normal State Door-open State

AS

I-89

10

AS

I-89

10

GND +12V COM NO NC GND SW BELL BELL

Function DebuggingFunction Debugging

Test Reading Card

Test the Keypad

Test Output

Test Input

Live Safely and Conveniently

Page 9: Integrated Access Controller

1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.

2. If there is no sound when press the keys, the keypad maybe damaged.

3. When add card, if the device exits program mode automatically, the memory maybe damaged.

4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.

5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.

6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.

7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.

8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.

The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.

In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

3.5V

AS

I-89

10

AS

I-89

10

Product Maintenance Product Maintenance

Live Safely and Conveniently

Common Question

Page 10: Integrated Access Controller

安全生活● 方便生活

AS

I-89

20

AS

I-89

20

1 2 3

4 5 6

7 8 9

0 #

150mm

88

mm

30mm

Product Manual

The Front The Side

485 232

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

Fixing Hole

Jumper

The Back

Fixing Hole

Fixing Hole

Working Voltage:DC9-15VStatic Current:≤110mAReading Distance: 5-10cmCard Type: ID cardWorking Temperature: -15℃~55℃Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode:RS232/RS485Reader Interface: Wiegand 26

Product Parameters

Page 11: Integrated Access Controller

AS

I-89

20

AS

I-89

20

1. Remove the two keys first.

Installation ManualInstallation Manual

2. Unfasten the two screws.

Push up the back cover to open

First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.

3. Open the back cover and connect the device according to the wiring diagram.

4. Fix the backcover on the wallReassemble the device. (according

to 1, 2 and 3 in reversed order.

Live Safely and Conveniently

Page 12: Integrated Access Controller

AS

I-89

20

AS

I-89

20

485 232

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

485 232

GND

12V

DAT0

DAT1

SW

GND

MenC1

BELL

BELL

RX

TX

GND

485+

485-

2C

2NO

1NO

1C

1NC

GND

Power Interface

ReaderInterface

Exit Button Interface

RS232Interface

Door Magnet Alarm OutputInterface

Lock Control Interface

Door Magnet Interface

Door bellInterface

RS485Interface

ASI-8920 Interface

Product Connection Product Connection

Live Safely and Conveniently

Connect with Electric Bolt

Po

we

r In

terf

ace

ASI-8920 Interface

+12V

GND

Connect with Power

+12V

GND

V+ V- NOCOM NC

Connect with EM Lock

+-

+1

2V

GN

D

Fail-safe

Fail-secure

+12V 红 GND 黑 SIGNAL SIGNAL

+12V

GND

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

*Valid state:door magnet is normal open.

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

*Valid state:door magnet is normal open.

ASI-8920 Interface

Po

we

r In

terf

ace

ASI-8920 Interface

ASI-8920 Interface

Power InterfaceConnect with Electric Lock

Electric Bolt

Iron Core Cover Plate

Door Magnet

Po

we

r Inte

rface

Page 13: Integrated Access Controller

AS

I-89

20

AS

I-89

20

COM1

COM2

Exit Button

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

+1

2V

GN

D

+-

接读卡器

2620

1 2 3

4 5 6

7 8 9

* 0 #

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

BlackRedGreenWhite

ASI-8920 Interface ASI-8920 Interface

B

arr

ier

Inte

rfa

ce

(E

lectr

ic L

eve

l S

ign

al)

Common end

Stop

Close

Open

A

uto

ma

tic

Do

or

Inte

rfa

ce

(

Sw

itch

Sig

na

l)

The automatic door is open when COM1-COM2 is short circuit.

Connect with Automatic DoorConnect with Barrier

ASI-8920 Interface ASI-8920 Interface

Active Boorbell

Connect with Door Bell

Power Interface

ASI-8920 Interface

ASI-8920 Interface

Connect with Alarm Device Connect with Reader

Live Safely and Conveniently

Product ConnectionProduct Connection

Alarm Light

Page 14: Integrated Access Controller

AS

I-89

20

AS

I-89

20

Connect with RS485

For 485 communication, please follow the diagram for connection and no other connection mode should be used.

Converter48

5+

48

5-

12345

DB9-Hole

ComputerInterface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

12345

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS232

48

5 2

32

ASI-8920 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS232\TCP/IP

48

5 2

32

Rj45

ASV-TCP/IPDC9~30V

232

485

Rs232

9~30V+

9~30V-

485+

485-

Rs485

12

34

5

DB9-Hole

Rs232Connect with PC or Router

ASI-8920 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS485

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

PWD

RxD

TxD

RS

48

5

RS

23

2RS485-RS232Convertor

Co

mp

ute

rIn

terf

ace

T/R+T/R-GND

48

5 2

32

ASI-8920 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

48

5 2

32

Rj45

ASV-TCP/IPDC9~30V

232

485

Rs232

9~30V+

9~30V-

485+

485-

Rs485

Rs485

RS485\TCP/IP

Connect with PC or Router

ASI-8920 Interface

Live Safely and Conveniently

Product ConnectionProduct Connection

Page 15: Integrated Access Controller

1 2 3

4 5 6

7 8 9

0 #

A

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

Function Debugging Function Debugging

AS

I-89

20

AS

I-89

20

Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

When the buzzer sounds once,Dial “*”, the orange light flashes; Input“000000”, the orange light turns on and device enters program mode. This means the keypad is OK.

Adjust the multimeter to , When the power is on, in normal state, 1C-1NC is short circuit, while 1C-1NO is open circuit. When present the valid card or press the exit button, 1C-1NC turns into open circuit, while 1C-1NO is short circuit.

1C1NC

1NO1C

1NC

1NO

Normal State Door-open State

Test Reading Card

Test the Keypad

Test Output

Test Input

If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close.The user can decide the type of default input setup in the software. 8920 has two input interfaces: SW-GND is button input; MenCi-GND is door magnet input. Both of them can be changed in “channel setup”.

ASI-8920 Interface

ASI-8920 Interface

Live Safely and Conveniently

Page 16: Integrated Access Controller

Function DebuggingFunction Debugging

AS

I-89

20

AS

I-89

20

After the exterior device is connected with ASI-8920, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.

Connect with Exterior Identification Device

1. Select the device

2.Start to read card

Test the Communication

Rs485

ASI-892 has two kinds of communication modes: RS232 and Rs485. User can chose the communication mode by setting up the jumper. ASI-8920 can connect with PC serial port, and one serial port only connects with one ASI-8920. RS485 signal should be converted to Rs232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8920 is connected with PC, user can detect ASI-8920 address by detecting serial port (please refer to the user manual to setup the address). If”connected” is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.

Setup the Jumper

Rs232

Test the time of ASI-8920

Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by press“Refresh”. If controller time is incorrect, card record may get lost, validity of card-read is in doubt, and moreover, valid card may turn into be invalid.

PC time should be in consistent with controller time; otherwise the reader may not work properly.*

3. Get the card number

Live Safely and Conveniently

Page 17: Integrated Access Controller

AS

I-89

20

AS

I-89

20

Product Maintenance Product Maintenance

Urgent Maintenance:1. When the exterior reader can not read the cards, please

test the voltage of DATA0—GND and DATA1---GND. If the

voltage is less than 3.5V, please weld TVS2, TVS3.2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5.3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.

PCB

Common Question1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.2. If there is no sound when press the keys, the keypad maybe damaged.3. When add card, if the device exits program mode automatically, the memory maybe damaged.4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.

The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.

In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

3.5V

Live Safely and Conveniently

Page 18: Integrated Access Controller

AS

I-89

30

AS

I-89

30

1 2 3

4 5 6

7 8 9

0 #

150mm

88mm

30mm

设备参数

Product Manual

485 232

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

Fixing Hole

Jumper

The Back

Fixing Hole

Fixing Hole

The SideThe Front

Working Voltage:DC9-15VStatic Current:≤120mAReading Distance: 5-10cmCard Type: ID cardWorking Temperature: -15℃~55℃Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode:RS232/RS485Reader Interface: Wiegand 26

Product Parameters

Live Safely and Conveniently

Page 19: Integrated Access Controller

AS

I-89

30

AS

I-89

30

Installation ManualInstallation Manual

Live Safely and Conveniently

1. Remove the two keys first. 2. Unfasten the two screws.

Push up the back cover to open

First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.

3. Open the back cover and connect the device according to the wiring diagram.

4. Fix the backcover on the wallReassemble the device. (according

to 1, 2 and 3 in reversed order.

Page 20: Integrated Access Controller

485 232

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

485 232

GND

12V

DAT0

DAT1

SW

GND

MenC1

BELL

BELL

RX

TX

GND

485+

485-

2C

2NO

1NO

1C

1NC

GND

Power Interface

ReaderInterface

Exit Button Interface

RS232Interface

Door Magnet Alarm OutputInterface

Lock Control Interface

Door Magnet Interface

Door bellInterface

RS485Interface

ASI-8930 Interface AS

I-89

30

AS

I-89

30

Connect with Electric Bolt

Po

we

r In

terf

ace

ASI-8930 Interface

+12V

GND

Connect with Power

+12V

GND

V+ V- NOCOM NC

Connect with EM Lock

+-

+1

2V

GN

D

Fail-safe

Fail-secure

+12V 红 GND 黑 SIGNAL SIGNAL

+12V

GND

GND12VDAT0DAT1SW

GNDMenC1

BELLBELL

RXTX

GND485+485-

2C2NO1NO

1C1NC

GND

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

*Valid state:door magnet is normal open.

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

*Valid state:door magnet is normal open.

ASI-8930 Interface

Po

we

r In

terf

ace

ASI-8930 Interface

ASI-8930 Interface

Power InterfaceConnect with Electric Lock

Electric Bolt

Iron Core Cover Plate

Door Magnet

Po

we

r Inte

rface

Live Safely and Conveniently

Product ConnectionProduct Connection

Page 21: Integrated Access Controller

AS

I-89

30

AS

I-89

30

COM1

COM2

Exit Button

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

+1

2V

GN

D

+-

接读卡器

2620

1 2 3

4 5 6

7 8 9

* 0 #

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

BlackRedGreenWhite

ASI-8930 Interface ASI-8930 Interface

B

arr

ier

Inte

rfa

ce

(E

lectr

ic L

eve

l S

ign

al)

Common end

Stop

Close

Open

A

uto

ma

tic

Do

or

Inte

rfa

ce

(

Sw

itch

Sig

na

l)

The automatic door is open when COM1-COM2 is short circuit.

Connect with Automatic DoorConnect with Barrier

ASI-8930 Interface ASI-8930 Interface

Active Boorbell

Connect with Door Bell

Power Interface

ASI-8930 Interface

ASI-8930 Interface

Connect with Alarm Device Connect with Reader

Live Safely and Conveniently

Alarm Light

Product ConnectionProduct Connection

Page 22: Integrated Access Controller

安全生活● 方便生活

AS

I-89

30

AS

I-89

30

Connect with RS485

For 485 communication, please follow the diagram for connection and no other connection mode should be used.

Converter48

5+

48

5-

12345

DB9-Hole

ComputerInterface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

12345

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS232

48

5 2

32

ASI-8930 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS232\TCP/IP

48

5 2

32

Rj45

ASV-TCP/IPDC9~30V

232

485

Rs232

9~30V+

9~30V-

485+

485-

Rs485

12

34

5

DB9-Hole

Rs232Connect with PC or Router

ASI-8930 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

RS485

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

PWD

RxD

TxD

RS

48

5

RS

23

2RS485-RS232Convertor

Co

mp

ute

rIn

terf

ace

T/R+T/R-GND

48

5 2

32

ASI-8930 Interface

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

48

5 2

32

Rj45

ASV-TCP/IPDC9~30V

232

485

Rs232

9~30V+

9~30V-

485+

485-

Rs485

Rs485

RS485\TCP/IP

Connect with PC or Router

ASI-8930 Interface

Product ConnectionProduct Connection

Page 23: Integrated Access Controller

A

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

GN

D1

2V

DA

T0

DA

T1

SW

GN

DM

en

C1

BE

LL

BE

LL

RX

TX

GN

D4

85

+4

85

-2

C2

NO

1N

O1C

1N

C

GN

D

1 2 3

4 5 6

7 8 9

0 #

Function DebuggingFunction Debugging

AS

I-89

30

AS

I-89

30

Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

When the buzzer sounds once,Dial “*”, the orange light flashes; Input“000000”, the orange light turns on and device enters program mode. This means the keypad is OK.

1 , 1 1

Adjust the multimeter to , When the power is on, in normal state, 1C- NC is short circuit while C- NO is open circuit. When present the valid card or pressthe exit button, 1C-1NC turns into open circuit, while 1C-1NO is short circuit.

1C1NC

1NO1C

1NC

1NO

Normal State Door-open State

Test Reading Card

Test the Keypad

Test Output

Test Input

If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close.The user can decide the type of default input setup in the software. 8930 has two input interfaces: SW-GND is button input; MenCi-GND is door magnet input. Both of them can be changed in “channel setup”.

Test Reading Card

ASI-8930 Interface

ASI-8930 Interface

Live Safely and Conveniently

Page 24: Integrated Access Controller

After the exterior device is connected with ASI-8930, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.

Connect with Exterior Identification Device1. Select the device

2.Start to read card

3. Get the card number

AS

I-89

30

AS

I-89

30

Test the LCD

The LCD will display the Anson and the time, after turn on the power for ASI-8930.

Anson2007-04-16 14:20

1 2 3

4 5 6

7 8 9

0 #

Test the Communication

Rs485

ASI-8930 has two kinds of communication modes: RS232 and RS485. User can chose the communication mode by setting up the jumper. ASI-8930 can connect with PC serial port, and one serial port only connects with one ASI-8930. RS485 signal should be converted to RS232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8930 is connected with PC, user can detect ASI-8930 address by detecting serial port (please refer to the user manual to setup the address). If “connected” is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.

Setup the Jumper

Rs232

Test the time of ASI-8930

Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by press“Refresh”. If controller time is incorrect, card record may get lost, validity of card-read is in doubt, and moreover, valid card may turn into be invalid.

PC time should be in consistent with controller time; otherwise the reader may not work properly.*

Live Safely and Conveniently

Function DebuggingFunction Debugging

Page 25: Integrated Access Controller

Urgent Maintenance:1. When the exterior reader can not read the cards, please

test the voltage of DATA0—GND and DATA1---GND. If the

voltage is less than 3.5V, please weld TVS2, TVS3.2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5.3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.

PCB

Common Question1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.2. If there is no sound when press the keys, the keypad maybe damaged.3. When add card, if the device exits program mode automatically, the memory maybe damaged.4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.9. The LCD have no information to be displayed, after turn on the power for ASI-8930. The starting program maybe damaged.

The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.

In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

3.5V

Live Safely and Conveniently

Product MaintenanceProduct MaintenanceA

SI-8

93

0A

SI-8

93

0