4
Intruder and blast resistant security doors SECUR-DOR TESTED TO BS EN 1627:2011 CERTIFIED BY Warrington Exova Certisecure STS 202 PAS 24 (SECUR-DOR SD4) BS EN 13124-2:2004 EXR2 EXPLOSIVE RESISTANT INTRUDER RESISTANT
Transcript
Page 1: Intruder and blast resistant security doors INTRUDER RESISTANT · BS EN 13124-2:2004 EXR2 EXPLOSIVE RESISTANT INTRUDER RESISTANT. We offer three versions – each providing increased

Intruder and blast resistant security doors

SECUR-DOR

TESTED TO

BS EN 1627:2011

CERTIFIED BY

Warrington Exova Certisecure STS 202

PAS 24

(SECUR-DOR SD4)

BS EN 13124-2:2004EXR2

EXPLOSIVERESISTANT

INTRUDER RESISTANT

Page 2: Intruder and blast resistant security doors INTRUDER RESISTANT · BS EN 13124-2:2004 EXR2 EXPLOSIVE RESISTANT INTRUDER RESISTANT. We offer three versions – each providing increased

We offer three versions – each providing increased security (latched or unlatched):

Security DoorTested to

STS202 BR2 & PAS24

protect low to medium risk properties from

determined opportunist attempts at forced entry using a variety of hand

tools. They are particularly suitable as apartment

doors for residential and social housing.

Security DoorTested to

STS202 BR3Protect medium risk

residential or commercial properties from attempts at forced entry, with little

regard for noise, using heavy hand tools.

Security and Blast Door

Tested to ENV 1627 Level 4

Protect medium to high risk properties from

experienced attempts at forced entry, regardless

of noise, using heavy hand and battery tools or

explosives.

Certified Steel Security DoorsOur Security Doors been tested to and passed Warrington Exova Certisecure STS 202 and PAS 24 standards.

Our Security Doors have also been tested to and passed BS EN 1627:2011 and European Security Standard DD ENV 1627:1999.

SECUR-DOR

Did you know we send out touch up kits with every door?

> VERSIONS

> DOOR LEAF

Production Sizes: All SECUR-DOR doors are custom made. The maximum size varies according to fire rating as shown below for Mild Steel and 316 or 304 Stainless Steel.

Single Doors Latched(Single Swing)

Max Width mm 1300 1300 1250

Max Height mm 2800 2800 2800

Double Doors (Single Swing - Latched or unlatched, equal or unequally split)

Max Width mm 2700 2700 2600

Max Height mm 2800 2800 2800

Thickness: mm 48 55 48

Material: 1.5mm corrosion resistant Zintec/Aluzinc sheets as

standard

2mm corrosion resistant Zintec/Aluzinc sheets as

standard

1.5mm corrosion resistant Zintec/Aluzinc sheets as

standard

Infill: Filled with mineral wool and integral steel

stiffeners.

Filled with mineral wool and integral steel

stiffeners.

Solid timber cored with internal stainless steel steel anti-attack skin

Construction: Doorblade manufactured from two 1.5mm sheets lockformed together, by bonding two steel skins

around a rigid core. A total steel armour thickness of

3 - 4mm.

Doorblade manufactured from two 2mm sheets

lockformed together, by bonding two steel skins

around a rigid core. A total steel armour thickness of

4mm. Fitted with anti-tamper hinges.

Doorblade manufactured from two 1. 5mm sheets

lockformed together, by bonding two steel

skins around a rigid core. Additionally fitted with a 1.5mm stainless steel

sheet to the internal face of the outer skin and a solid timber core. Fitted with a full length continuous

hinge. A total steel armour thickness of 4.5mm. Fitted

with integral lock box.

> FINISHES

Polyester PowderCoated from Standard Colour Range

Standard

Polyester PowderCoated from Non-Standard Colour Range

Unfinished forsite finishing

Optional

All of our doors are made to measure!

ORDER HOTLINE: 00000 0000000 e: [email protected] www.customerwebaddress.com

Page 3: Intruder and blast resistant security doors INTRUDER RESISTANT · BS EN 13124-2:2004 EXR2 EXPLOSIVE RESISTANT INTRUDER RESISTANT. We offer three versions – each providing increased

Standard: 15mm rebated(DDA compliant)

Optional: 5mm driveable

(DDA compliant)

Permitted panel sizes: Max Width mm 610

Max Height mm 1854

Max Area m2 0.4

Standard glazings available: Other configurations and sizes available – please contact the Sales Office.

11.5mm laminated

(wired or clear)

> VISION PANELS

Standard

457mm dia305mm dia 254x254mm 254x559mm

> DOOR FRAME

> THRESHOLD

Construction: Material: Folded and welded from 1.6mm Zintec/Aluzinc.

Folded and welded from 2mm Zintec/Aluzinc.

Folded and welded from 3mm Zintec/Aluzinc.

Sub-Frame: Fully welded, variable sub-frame supplied as standard to

accommodate site tolerance of -0/+30mm.

The sub-frame providing additional protection to the

fixings against jemmys.

Folded and welded from 2mm Zintec/Aluzinc. Fully welded, variable sub-frame supplied

as standard to accommodate site tolerance of -0/+30mm.

Complete with Anti-Crush plate. The sub-frame providing

additional protection to the fixings against jemmys.

Specially modified, variable sub-frame supplied as standard to accommodate site tolerance of -0/+30mm. The sub-frame

providing additional protection to the fixings against jemmys.

Fixings: Four specially modified Class 13 stainless steel hinges with four security dog bolts for security.

Four Class 13 stainless steel dog bolt hinges recessed and specially modified to prevent pin extraction. Plus two solid

ball round dog bolts to increase resistance to prising

Stainless steel dog bolted continuous hinges for additional

security.

Infill: Mineral wool Mineral wool

Profile: (see diagrams below) A, B, C A, B, C, D C, D

TYPE BTYPE A TYPE C TYPE D

100

15

113,6

6,34

Only available on SECUR-DOR2 PAS 24

ORDER HOTLINE: 00000 0000000 e: [email protected] www.customerwebaddress.com

Page 4: Intruder and blast resistant security doors INTRUDER RESISTANT · BS EN 13124-2:2004 EXR2 EXPLOSIVE RESISTANT INTRUDER RESISTANT. We offer three versions – each providing increased

Individual specifications may vary as we conduct a policy of continuous product development.

> SECURE LOCKING

> THERMAL VALUES

> APPLICATIONS

> TESTING

Locking: PAS 24Fitted with high security Deadlock or

Sashlock (c/w lever handles or pull handle) & double europrofile cylinder and fitted

with TS007 security escutcheons.

STS202 (BR2) Fitted with a minimum of two high security

locks;1 no Securefast C EN grade 7 security

sashlock and lever handle, (SA 222 50SS R/7) double europrofile cylinder and fitted with TS007 security escutcheons fitted to

the centre door position1 no Securefast C EN grade 7 security deadlock, (SA21250 SS R /7) double

europrofile cylinder and fitted with TS007 security escutcheons fitted to the lower

quarter of the door leaf.

Fire Escape DoorsAlternatively the doors can be fitted with 3 point heavy duty panic escape hardware to offer means of escape, which is accepted

by the Secure by Design scheme.

Fire Escape Doors are fitted with a 1.2mm internal skin to resist drill attack.

Note: Taller doors may require a third, additional, lock.

3 no individual high security locks for enhanced security

High Security triple point high security sashlock, Securefast, with High Security

cylinders and anti-jemmy escutcheon protecting against snapping attack.

Lock is anti-drill and pattern protected to reduce the risk of key copying. Doors

are fitted with Exidor tower bolts.

Alternatively doors can be fitted with with three point heavy duty Panic

Hardware for Fire Escape but must be fitted with a Locking Box to prevent Drill

Attack.

Double doors are fitted with heavy duty tower bolts to inactive leaf.

A centre High Security Sashlock combined with two similar Deadlocks in the upper and lower quarters of the door. All locks fitted with anti-jemmy

escutcheon and welded shroud. Locks are anti-drill and pattern protected

to reduce risk of key copying. MICO TINDALL and Surelock McGill hardware

can also be used. Doors are fited with Exidor tower bolts.

Alternatively high security multi-point heavy duty panic hardware for fire

escapes.

Double doors are fitted with heavy duty tower bolts to inactive leaf..

Obtainable thermal values with infill as detailed:

2.4 w/m2k 2.6 w/m2k 2.9 w/m2k

Duty: Light commercial and perimeter security.

Protection from a determined attack, with some preparation and a number

of tools where the attacker is willing to make some, but not prolonged, noise.

Note: All duty recommendations assume the doors are used in

conjunction with othercomparable levels of security at

windows, etc.

The SD2 door can offer up to 120min. fire rating if fitted with appropriate

ironmongery

Medium risk residential and commercial properties which may be obscured from

view.

Protection from a deliberate forced entry of a well protected property using a wide variety of tools with little regard

for noise.

Note: All duty recommendations assume the doors are used in

conjunction with other comparable levels of security at windows etc.

The SD3 door can offer 120min. fire rating if fitted with appropriate

ironmongery.

Heavy duty and vulnerable properties, probably with a prior record of attempts

at forced entry.

Protection from experienced attempts at forced entry of commercial properties

with no regard for noise.

Further the door is suitable for protection against attempted entry by

explosive blasts.

Note: All duty recommendations assume the doors are used in

conjunction with other comparable levels of security at windows, etc.

Security: These doors achieve a pass to the following: PAS24 and STS202 (BR2). Both of which are accepted by Secure

by Design.BS EN 1627 level 2

Tests involve a determined attack over a period of 15mins. using tools

including screwdriver, 300mm. lever, and hammer.

When fitted with Vision Panels the door can only be offered to PAS24 rating.

The SD2 holds Secure by Design certification.

These doors achieve a pass to the following: STS202 (BR3) which is

accepted by Secure by Design. BS1627 level 3

Tests involves a determined attack over a period of 20mins. using tools

including hand hammer, hand drill, and crowbar.

Tested to BS 1627 level 4The test involves a determined attack

over a period of 30mins. using a selection of hand and battery tools

including club hammer, cordless drill, cold chisel and axe.

Blast: N/A N/A SD4 doors have been tested and passed EXR2 of BS EN 13124-2, Explosion Resistance standard, with explosive

blasts using plastic explosives.


Recommended