FibeAir ® IP-10 CLI (Command Line Interface) User Guide Part ID: BM-0134-0 Doc ID: DOC-00018394 Rev a.01 May 2008
Transcript
Page 1: IP10-CLI

FibeAir® IP-10

CLI (Command Line Interface)

User Guide

Part ID: BM-0134-0 Doc ID: DOC-00018394 Rev a.01

May 2008

Page 2: IP10-CLI

Notice This document contains information that is proprietary to Ceragon Networks Ltd.

No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd.

This document is provided as is, without warranty of any kind.

Registered TradeMarks Ceragon Networks® is a registered trademark of Ceragon Networks Ltd.

FibeAir® is a registered trademark of Ceragon Networks Ltd.

CeraView® is a registered trademark of Ceragon Networks Ltd.

Other names mentioned in this publication are owned by their respective holders.

TradeMarks CeraMapTM, PolyViewTM, EncryptAirTM, ConfigAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd.

Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions The information contained in this document is subject to change without notice.

Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment.

Copyright © 2008 by Ceragon Networks Ltd. All rights reserved.

Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] www.ceragon.com

European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected]

North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]

APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011

Page 3: IP10-CLI

Contents

General .......................................................................................................... 1

Getting Started.............................................................................................. 2

Command Groups......................................................................................... 5

CLI Commands.............................................................................................. 8

CLI Command Parameters ..........................................................................11

Page 4: IP10-CLI

FibeAir® IP-10 CLI Guide 1

General This guide explains how to work with the FibeAir® IP-10 Command Line Interface (CLI).

The CLI is used to perform IP-10 configuration and obtain system statistical and performance information.

Using the CLI, you can perform configuration operations for single IP-10 units, as well as configure several IP-10 units in a single batch command.

Access Rights

IP-10 CLI access is granted for the following user groups:

Viewer This user only has read-only access. The user can only view parameters and their values, not modify them.

Operator This user has read-write access. The user can read parameters and their values, and modify them. However, this user cannot add or remove other users.

Admin This user has read-write access. The user can read parameters and their values, modify them, and add/remove other users.

Technician This user has read-write access to the CLI, as well as access to a bridge-specific CLI shell.

User access is controlled by the system administrator and configured via the Management command group (shown in the Command Groups section).

Page 5: IP10-CLI

FibeAir® IP-10 CLI Guide 2

Getting Started To log in to the CLI:

1. Power on your PC.

2. Make sure that your PC is connected to the management port on the front panel of the IP-10 unit.

3. For a first-time login, use the following:

User: admin Password: admin

Note: When using the Hyper Terminal, you should set the terminal speed (in your PC terminal configuration) to 155200 kpbs. In addition, it is recommended to select the VT-100 terminal type and set the terminal size to 24 rows, 80 columns.

Getting Help

Once you are logged in, you can go to a main command group and its sub groups, type the command you want, and press Tab twice for a list of possible parameter values.

In addition, you can type a command and then type a question mark (?) for location-specific information for the command. For example, for the set command, typing set ? and pressing Enter will display a list of optional parameters and a help line.

Wherever you are in the command tree, you can obtain a list of available commands by typing Help or ?.

The commands that are available are different for each location in the CLI tree and the type of user.

Basic Commands

The following basic commands are available when you first log in, if you belong to the Operator user group:

ls list entities get get parameter set set parameter help help cd change directory exit exit CLI logout logout from CLI cli-ver cli version cls clear screen write write the current switch configuration to the configuration file show-tree show entity tree find search for a string in the parameter name and information fields lsp list entity parameters and commands

In addition, you can use the up/down arrow keys, or the “q” key, when the word “END” appears at the end of the screen.

Page 6: IP10-CLI

FibeAir® IP-10 CLI Guide 3

Finding Commands

At any point in the CLI tree, a quick way to find a command is to type find string, and press Enter. For string you can type any word that you think is relevant for a command.

For example, if you type find user, and press Enter, you would get a list of commands relating to "user", as follows: 1) management/mng-services/mng-software/proxy-user User name passed to the ... 2) management/mng-services/users/add-user Add user <name> <group> 3) management/mng-services/users/delete-user Delete user <name> 4) management/mng-services/users/show-users Show users

Command Example

The following example shows how you can find a command within a sub-group, and then execute the command. The example starts with the lsp (list parameters) command, and ends with the activation of an interface loopback test.

-----------------------------------------------

IP-10:/> cd diagnostics/loopback/radio-loopback/ IP-10:/diagnostics/loopback/radio-loopback> lsp *********** configuration ******** timeout rw Loopback timeout in minutes *********** statuses ************* counter ro Loopback time left if-loopback rw IF loopback activation rfu-rf-loopback rw RFU RF Loopback Enable Command rfu-if-loopback rw RFU IF Loopback Enable Command IP-10:/diagnostics/loopback/radio-loopback> set timeout 2 IP-10:/diagnostics/loopback/radio-loopback> set if-loopback off on IP-10:/diagnostics/loopback/radio-loopback> set if-loopback on Caution: This action affects traffic. The may cause permanent loss of Ethernet traffic & wayside. Consider disabling or physically disconnecting the Ethernet ports of the IDM and Wayside before the loopback activation. Are you sure? (yes/no):yes IP-10:/diagnostics/loopback/radio-loopback>

-----------------------------------------------

Important!

Note that bridge related commands need to be followed by a “write” command to be saved.

Otherwise, the commands will not be saved following a reset in the system.

Page 7: IP10-CLI

FibeAir® IP-10 CLI Guide 4

Viewing the Command Tree

At any location within the command group structure, you can type show-tree and press Enter for a list of all the commands in the group you are currently in.

The following list appears when you type show-tree.

Page 8: IP10-CLI

FibeAir® IP-10 CLI Guide 5

Command Groups

The command groups that appear when you log in include the following:

Management

Platform

Radio

Interfaces

Diagnostics

Some groups include sub groups that enable setup operations relevant to that category.

The following illustrations show the trees of each main group.

Management

Management

Page 9: IP10-CLI

FibeAir® IP-10 CLI Guide 6

Platform

Radio

Page 10: IP10-CLI

FibeAir® IP-10 CLI Guide 7

Interfaces

Diagnostics

Page 11: IP10-CLI

FibeAir® IP-10 CLI Guide 8

CLI Commands

The following table lists the commands you can use in each command group and sub group.

Note that when you enter a group or sub group, you can type a command and then press the Tab key twice (or type a question mark) for a list of values relevant to that command.

Command Group Command Description

alarm-current show Show current alarms

bridge qos-show-ip-pbit-val Show IP pbits to queue allocation

bridge qos-show-vlan-priority Show QoS VLAN Priorities

bridge qos-show-vlan-tag-pbit-val Show VLAN tag pbits to queue allocation

bridge show-eth-statistics Show Ethernet Statistics

bridge show-ports-status Show status of all ports

bridge show-running-config Show current switch operating configuration

bridge show-vlan-info Show VLAN database information

bridge vlan Add, remove or modify values associated with a single VLAN

cfg-service set-to-default Set to default

eth-port qos-show-policer-classes Show policer classes

eth-port qos-show-vlan-pbits-prio-remap Show VLAN Pbits priority remap

eth-port set-allowed-vlans Set allowed VLANs

eth-port show-allowed-vlans Show allowed VLANs

eth-port show-port-status Show port status

event-log clear Clear log

event-log show Show log

Page 12: IP10-CLI

FibeAir® IP-10 CLI Guide 9

Command Group Command Description

idc-board reset-idc-hw Reset the IDC - cold (HW) reset

mate-idu copy-to-mate-cmd Copy to mate command

mate-idu create-copy-to-mate-nack-list-cmd

Create copy to mate nack list command

mate-idu manual-switch-cmd Manual switch command

mng-protocols status-show Show Management Protocols status

mng-snmp status-show Show SNMP status

mng-software download Download all relevant packages from remote server (without installation)

mng-software kernel-upgrade Upgrade Linux kernel

mng-software package-install Install new package (like SW patch) without existing version installed

mng-software package-rollback Package rollback (downgrade to older version)

mng-software package-uninstall Uninstall SW package (recommended for patch removal)

mng-software show-packages Show SW package information

mng-software upgrade Upgrade all installed packages or requested package

mng-software verify-packages Verify installed packages

mstp msti-vid VLAN ID to be associated to instance

mstp show-msti-vid Show VLAN IDs associated to instance

pm-service clear-entire-pm Clear entire PM

remote-idu remote-cold-reset Reset the remote IDC - cold (HW) reset

rmon clear-all Clear RMON statistics from all ports

rmon clear-port Clear RMON statistics from a specific port

Page 13: IP10-CLI

FibeAir® IP-10 CLI Guide 10

Command Group Command Description

rmon get-statistics Get RMON statistics

users add-user Add user

users delete-user Delete user

users show-users Show users

Page 14: IP10-CLI

FibeAir® IP-10 CLI Guide 11

CLI Command Parameters

The following table lists the parameters you can use in the command groups and sub groups.

Command

Group Paremeter Description

alarm-current current-alarm-table System Alarm Current table indexed by time and quasi-sequential number

alarm-current most-severe Most severe alarm alarm-current sequence-count Current alarm counter

bridge customer-l2protocol Customer L2 protocols (STP, LACP, GMRP, GVRP, MMRP, MVRP, DOT1X) tunneling

bridge ethernet-application Ethernet application bridge forward-time Forwarding delay time in seconds bridge hello-time Hello time in seconds bridge management-type Management type bridge max-age Maximum ageing time in seconds bridge max-hops Maximum hops the BPDU will be valid bridge msti-bridge-priority Bridge priority for each defined MST instance bridge priority Bridge priority bridge qos-ip-precedence-val IP precedence IP pbits value bridge qos-ip-tos-tc-pbits-option IP TOS/TC pbits options bridge stp-protocol Spanning-tree protocol e1t1-port admin Enable/Disable the port e1t1-port cable-length T1 cable length e1t1-port interface-type Interface type e1t1-port line-loopback Line loopback e1t1-port line-pm-15 Line PM 15 minutes monitoring e1t1-port line-pm-24 Line PM 24 hours monitoring e1t1-port oper-status Operational status e1t1-port port-curr-ber E1/T1 port current BER e1t1-port priority Dynamic allocation priority ethernet gbe-mute-override GbE mute override eth-port actual-duplex Actual duplex eth-port actual-ethernet-rate Actual ethernet rate eth-port admin Enable/Disable the port eth-port auto-negotiation Auto negotiation eth-port bad-octets-rcv Bad octets received eth-port brdc-pkts-rcv Broadcast packets received eth-port brdc-pkts-sent Broadcast packets sent eth-port collisions Collisions eth-port connector-type Connector type eth-port deferred Deferred eth-port duplex Half/Full duplex eth-port ethernet-rate Ethernet rate (mbps)

Page 15: IP10-CLI

FibeAir® IP-10 CLI Guide 12

Command Group Paremeter Description

eth-port evc-name EVC name eth-port excess-collision-drop Excess Collision Frame eth-port flow-control Flow Control eth-port fragments-pkts Fragments Packets eth-port functionality-led Functionality LED eth-port functionality-led.blink blink attribute eth-port good-octets-rcv Good octets received eth-port good-octets-sent Good octets sent eth-port in-discards In Discards eth-port in-fcs-err In FCS Error eth-port in-filtered In Filtered eth-port in-pause In Pause eth-port in-rx-err In receive error eth-port interface-index Interface index eth-port interface-type Interface type eth-port in-uni-casts In Uni-Cast eth-port jabber-pkts Jabber Packets eth-port late-collision-detect Late Collision Detect eth-port learning Learning admin

eth-port management-auto-negotiation Management port auto negotiation

eth-port management-capacity Management port capacity eth-port management-duplex Management port duplex

eth-port management-ethernet-rate Management port Ethernet rate (Mbps)

eth-port management-only Management only eth-port management-port-admin Port's admin eth-port management-vlan Management VLAN id eth-port mc-pkts-rcv Mc packets received eth-port mc-pkts-sent Mc packets sent eth-port msti-port-path-cost Path cost for each defined MST instance eth-port msti-port-priority Interface priority for each defined MST instance eth-port multiple-collision-frame Multiple Collision Frame eth-port oper-status Operational status eth-port out-fcs-err Out FCS error eth-port out-filtered Out filtered eth-port out-pause Out pause eth-port out-uni-casts Out Uni-Cast eth-port oversize-pkts Oversize packets eth-port path-cost Path cost eth-port pkts-1024-max-octets Number of packets with size equal or greater than 1024 octetseth-port pkts-128-255-octets Number of packets with size between 128 and 255 octets eth-port pkts-256-511-octets Number of packets with size between 256 and 511 octets eth-port pkts-512-1023-octets Number of packets with size between 512 and 1023 octets eth-port pkts-64-octets Number of packets with size equal or smaller to 64 octets

Page 16: IP10-CLI

FibeAir® IP-10 CLI Guide 13

Command Group Paremeter Description

eth-port pkts-65-127-octets Number of packets with size between 65 and 127 octets eth-port priority Port's priority eth-port protection-only Protection only eth-port protection-port-admin Port's admin eth-port qos-classifier-criteria Classifying criteria eth-port qos-egress-shaper Egress shaper

eth-port qos-egress-shaper-rate Egress shaper rate. The value should be in steps. The steps are: 64K - for values less than 1Mbps. 1M - for values between 1Mbps and 100Mbps. 10M - for values between 100Mbps and 1000Mbps (GbE Ports Only)

eth-port qos-marker QoS marker eth-port qos-policer-action Policer action eth-port qos-policer-cbs eth-port qos-policer-class-name Policer class name associate to this policer eth-port qos-policer-name Policer name associated to this port eth-port qos-policer-rate Policer rate eth-port qos-policer-type Policer type eth-port qos-prio-override-port Priority override port eth-port qos-scheduling-scheme Scheduling scheme eth-port qos-vlan-pbits-prio-remap VLAN pbits priority remap eth-port role Port's role eth-port rstp-edge-port Enable as edge port eth-port rstp-link-type Link type eth-port single-collision-frame Single Collision Frame eth-port state Port's state eth-port type Port's type eth-port undersize-pkts Undersize packets eth-port vlan Default VLAN ID eth-port wayside-auto-negotiation Wayside auto negotiation eth-port wayside-capacity Wayside Port Capacity eth-port wayside-duplex Wayside half/full Duplex eth-port wayside-ethernet-rate Wayside Ethernet port rate (Mbps) eth-port wayside-only Wayside only eth-port wayside-port-admin Port's admin event-log log-count log counter

event-log log-table System event log table indexed by time and quasi-sequential number

fpga fw-version FPGA FW Version framer link-id Link ID framer oper-status Operational status framer radio-ber Radio BER Status

framer radio-excessive-ber-threshold Radio Excessive BER Threshold Configuration

framer radio-pm-15min-interval Radio 15 minutes interval performance monitor framer radio-pm-24hour-interval Radio 24 hours interval performance monitor framer radio-signal-degrade- Radio Signal Degrade Threshold Configuration

Page 17: IP10-CLI

FibeAir® IP-10 CLI Guide 14

Command Group Paremeter Description

threshold idc-board idu-led IDU LED idc-board idu-led.blink blink attribute idc-board measurement-system Measurement system idc-board protection-led Protection LED idc-board protection-led.blink blink attribute idc-board radio-led Radio LED idc-board radio-led.blink blink attribute idc-board remote-led Remote LED idc-board remote-led.blink Blink attribute idc-board rfu-led RFU LED idc-board rfu-led.blink blink attribute idc-board system-up-time System up time (in hundredths of second) idc-board temperature Temperature idc-board version IDC's Version inventory board-modules Board Modules inventory board-sub-type The sub-type of the board inventory board-type The type of the board inventory chain-firmware The firmware of the chain inventory chain-hardware-features The hardware features of the chain inventory chain-sub-type The sub-type of the chain inventory chain-type The type of the chain inventory comments Text description about the board inventory company-name Company name inventory date-code Date of board testing (number of seconds from 1/1/1970) inventory firmware Firmware inventory hardware Hardware inventory hass-number Number of hass testing inventory hw-supported-bit-bate HW supported bit bate inventory idc-firmware The firmware of the IDC inventory idc-hardware-features The hardware features of the IDC inventory idc-sub-type The sub-type of the IDC inventory idc-type The type of the IDC inventory license-demo-timer Number of hour left for license demo mode inventory license-register System license features inventory modem-firmware The firmware of the modem

inventory modem-hardware-features The hardware features of the modem

inventory modem-sub-type The sub-type of the modem inventory modem-system-rate The frequency of the clock for the PVG inventory modem-type The type of the modem inventory mux-firmware The firmware of the MUX inventory mux-hardware-features The hardware features of the MUX inventory mux-sub-type The sub-type of the MUX inventory mux-type The type of the MUX

Page 18: IP10-CLI

FibeAir® IP-10 CLI Guide 15

Command Group Paremeter Description

inventory num-of-10-100-1000-interfaces Number of 10/100/1000 interfaces

inventory num-of-fe-interfaces Number of fast Ethernet interfaces inventory num-of-sfp-interfaces Number of SFP interfaces inventory num-of-tdm-interfaces Number of TDM interfaces inventory num-of-working-hours Counter of working hours of the board inventory part-number Part number of the application in the board inventory product-name Product name

inventory rx-iq-delay-high-rate-systems RX IQ delay offset for high rate systems

inventory rx-iq-delay-low-rate-systems RX IQ delay offset for low rate systems

inventory serial-number The serial number of the board inventory spare1 Spare 1 inventory spare2 Spare 2 inventory spare3 Spare 3

inventory tx-iq-delay-high-rate-systems Tx IQ delay offset for high rate systems

inventory tx-iq-delay-low-rate-systems Tx IQ delay offset for low rate systems

inventory type-of-tdm-interfaces Type of TDM interfaces inventory xc-firmware The firmware of the XC inventory xc-hardware-features The hardware features of the XC inventory xc-sub-type The sub-type of the XC inventory xc-type The type of the XC ip-address default-gateway Default gateway ip-address hw-address Hw address ip-address ip-address Unit management IP address ip-address ip-v6-address IPv6 address ip-address subnet-mask Unit subnet mask license acm-license license capacity-name rate name license demo-admin license demo-timer Time left for license demo mode (in hours) license license-code license license-type license switch-application-license line-loopback counter Loopback time left line-loopback line-loopback Line loopback line-loopback timeout Loopback timeout in minutes (0 for unlimited) mate-idu copy-to-mate-nack-list

mate-idu excessive-ber-switch-enable

mate-idu mate-ip-address mate-idu mate-mac-address

Page 19: IP10-CLI

FibeAir® IP-10 CLI Guide 16

Command Group Paremeter Description

mate-idu protection-admin mate-idu protection-force-switch mate-idu protection-lockout mate-idu protection-mode mate-idu protection-role

mate-idu remote-ber-adjustment-time

mate-idu remote-lof-adjustment-time

mate-idu remote-sd-adjustment-time

mate-idu sd-switch-enable mng-protocols telnet-admin Telnet administrative state mng-protocols telnet-status Telnet service status mng-protocols web-admin Web administrative state mng-protocols web-status Web service status mng-snmp snmp-admin SNMP administrative state mng-snmp snmp-read-community SNMP read community mng-snmp snmp-status SNMP service status mng-snmp snmp-version SNMP version mng-snmp snmp-write-community SNMP write community mng-snmp trap-admin Enable/Disable sending SNMP traps mng-snmp trap-community SNMP trap community mng-snmp trap-group-filter SNMP trap group filter

mng-snmp trap-heartbeat How often (in minutes) a trap heartbeat is sent to the manager (0 to disable)

mng-snmp trap-manager Address of manager to which SNMP traps will be sent mng-snmp trap-name Text to name or comment the manager mng-snmp trap-port Manager port to which traps are sent (default 162) mng-snmp trap-severity-filter Filter which traps are sent to the manager by their severity. mng-software application-versions list of individual application packages and their versions

mng-software common-version common version identifying the whole application packages set

mng-software proxy-password Password passed to the proxy mng-software proxy-url Proxy URL mng-software proxy-user User name passed to the proxy mng-software server-login Remote server login mng-software server-password Remote server password mng-software server-url Remote SW Update server URL where SW updates reside mng-software status-download last SW download status mng-software status-install last SW installation status modem clear-counters Clear accumulated counters modem defected-blocks Defected blocks modem ldpc-decoder-stress LDPC decoder stress modem mse MSE

Page 20: IP10-CLI

FibeAir® IP-10 CLI Guide 17

Command Group Paremeter Description

mrmc connected-rfu-grade Actual connected rfu grade information

mrmc current-acm-adaptive-profile Current ACM adaptive profile Information

mrmc current-bitrate Current bit rate Information mrmc current-profile Current profile Information mrmc current-qam Current QAM Information mrmc loaded-script-description Loaded script description Information mrmc loaded-script-version Modem script version Information mrmc max-adaptive-acm-profile Maximum adaptive ACM profile Information

mrmc max-available-tdm-interfaces Max available TDM interface information

mrmc max-chosen-bitrate Max chosen bitrate information mrmc min-adaptive-acm-profile Min adaptive ACM profile Information mrmc mrmc-pm-15min-interval MRMC 15 minutes interval performance monitor mrmc mrmc-pm-24hour-interval MRMC 24 hours interval performance monitor mrmc mrmc-script MRMC script Information mrmc mse-threshold MSE threshold Information mrmc occupied-bandwidth Occupied bandwidth Information mrmc operation-mode Operation mode Information mrmc rfu-chosen-grade RFU chosen grade information mstp region-name Name of the MST region mstp revision-number Revision number for configuration information networking auto-negotiation Management port auto negotiation networking capacity Management port capacity networking duplex Management port duplex networking ethernet-rate Management port Ethernet rate (Mbps) networking number-of-ports Number of management ports networking type How management data is passed networking vlan Management VLAN id platform system-contact-person System contact person platform system-description System description platform system-location System location platform system-name System name port-group exber-threshold Excessive BER threshold Information port-group line-code Line code Information port-group pdh-led PDH LED color port-group pdh-led.blink blink attribute port-group sd-threshold Space Diversity threshold radio-loopback counter Loopback time left radio-loopback if-loopback IF loopback activation radio-loopback rfu-if-loopback RFU IF Loopback Enable Command radio-loopback rfu-rf-loopback RFU RF Loopback Enable Command radio-loopback timeout Loopback timeout in minutes remote-idu remote-atpc-enable Remote ATPC Enable/Disable configuration remote-idu remote-atpc-ref-rx-level Remote ATPC reference Rx level configuration

Page 21: IP10-CLI

FibeAir® IP-10 CLI Guide 18

Command Group Paremeter Description

remote-idu remote-communication Remote Communication Status remote-idu remote-default-gateway Remote IDU default gateway remote-idu remote-force-max-tx-level Force remote Max transmit level configuration remote-idu remote-force-mute-tx Force remote Mute transmitter configuration remote-idu remote-ip-address Remote IDU IP address remote-idu remote-link-id Remote IDU Link ID remote-idu remote-management-type Remote Management type Status remote-idu remote-management-vlan Remote Management VLAN ID configuration

remote-idu remote-most-severe-alarm Remote Most Severe Alarm Status

remote-idu remote-rx-level Remote Rx level status remote-idu remote-subnet-mask Remote IDU subnet mask rfic if-loopback IF loopback activation rfu atpc-enable RFU ATPC Enable/Disable rfu atpc-ref-rx-level RFU ATPC Reference Rx Level rfu band RFU band status rfu cable-tilt RFU cable tilt status rfu communication-status RFU communication to remote unit status rfu delay-calibration RFU delay calibration configuration

rfu delay-calibration-operation RFU delay calibration command

rfu delay-calibration-result RFU delay calibration result status rfu fpga-version-number RFU FPGA version number rfu hardware-reset RFU Reset Hardware Command rfu ifc-support RFU IFC support status rfu if-loopback-support RFU IF loopback support status

rfu internal-download-counter RFU internal download counter status

rfu internal-download-status RFU internal download status rfu log-enable RFU Log Enable/Disable Configuration rfu log-interval RFU Log interval configuration, in seconds rfu lo-sense RFU lo sense status rfu max-bandwidth RFU maximum bandwidth status rfu max-rx-freq RFU maximum Rx frequency status rfu max-tx-freq RFU maximum Tx frequency status rfu max-tx-level RFU Maximum Transmit Level Configuration rfu min-bandwidth RFU minimum bandwidth status rfu min-rx-freq RFU minimum Rx frequency status rfu min-tx-freq RFU minimum Tx frequency status rfu mse-forward RFU MSE forward command rfu mute-tx RFU Mute Transmitter rfu part-number RFU part number rfu pm-15min-interval RFU 15 minutes interval performance monitor

rfu pm-15min-interval-combined RFU 15 minutes interval combined performance monitor

rfu pm-15min-interval- RFU 15 minutes interval diversity performance monitor

Page 22: IP10-CLI

FibeAir® IP-10 CLI Guide 19

Command Group Paremeter Description

diversity rfu pm-24hour-interval RFU 24 hours interval performance monitor

rfu pm-24hour-interval-combined RFU 24 hours interval combined performance monitor

rfu pm-24hour-interval-diversity RFU 24 hours interval diversity performance monitor

rfu pmax RFU Pmax status rfu pmin RFU Pmin status

rfu pm-rx-level-threshold-1 RFU Performance Monitoring Rx Level Threshold 1 Configuration

rfu pm-rx-level-threshold-2 RFU Performance Monitoring Rx Level Threshold 2 Configuration

rfu pm-tx-level-threshold RFU Performance Monitoring Tx Level Threshold Configuration

rfu power-supply-status RFU Power Supply Status rfu predistortion-support RFU Predistortion support status rfu rf-loopback-support RFU RF loopback support status rfu rfu-address RFU address status rfu rfu-class RFU class status rfu rfu-if-loopback RFU IF Loopback Enable Command rfu rfu-installation RFU installation status rfu rfu-mode RFU Mode configuration rfu rfu-rf-loopback RFU RF Loopback Enable Command rfu rfu-type Type of connected RFU rfu rsl-connector-source RFU RX level connector source configuration rfu rx-freq RFU Rx frequency configuration rfu rx-freq-local-remote RFU Change Rx Frequency Local Remote Command rfu rx-level RFU Receive Level Status rfu rx-level-combined RFU Rx level combined status rfu rx-level-diversity RFU Rx level diversity rfu serial-number RFU serial number rfu software-version-number RFU software version number rfu standard-organization RFU standard organization rfu synthesizer-status RFU synthesizer rfu temp-in-celsius RFU Temperature In Celsius rfu temp-in-celsius-pa RFU temperature in Celsius on PA rfu temp-in-fahrenheit RFU Temperature In Fahrenheit rfu tx-freq RFU Tx Frequency Configuration rfu tx-freq-local-remote RFU Change Tx Frequency Local Remote Command rfu tx-level-status RFU Transmit Level rfu tx-rx-freq-separation RFU Tx Rx frequency separation rfu unfaded-rsl RFU Unfaded Rx Level Configuration

rfu-sw-upload internal-download-action RFU Internal Download Of Software/firmware/tables Action Command

rfu-sw-upload internal-download-counter RFU internal download counter status

Page 23: IP10-CLI

FibeAir® IP-10 CLI Guide 20

Command Group Paremeter Description

rfu-sw-upload internal-download-status RFU internal download status time-service time-and-date Time and date format: Day-Mon-Year,hour:min:sec wayside admin Enable/Disable Wayside channel wayside auto-negotiation Wayside auto negotiation wayside capacity Wayside channel capacity wayside duplex Wayside half/full Duplex wayside ethernet-rate Wayside Ethernet port rate (Mbps)