+ All Categories
Home > Documents > KCS-Standards (1 de 2)

KCS-Standards (1 de 2)

Date post: 04-Jan-2016
Category:
Upload: vladiblade
View: 73 times
Download: 5 times
Share this document with a friend
Description:
Normas arema para diseño de ferrocarriles 2
Popular Tags:
85
STANDARDS April 2007
Transcript
  • STANDARDSApril 2007

  • 4-27-07

    NONE

    RGT

    4-27-07INDEX OF DRAWINGS

    INDEX 1

    DWG No. DRAWING TITLE DWG No. DRAWING TITLE

    G-101

    G-102

    G-103

    G-104

    G-105

    G-106

    G-107

    G-108

    ENGLISH TO METRIC CONVERSION CHART

    SPEEDS THROUGH TURNOUTS

    PUSH CAR COUPLER

    FRA DEFINITIONS

    TEMPORARY TRACK AROUND OBSTRUCTIONS

    MINIMUM TARGET DISTANCE

    TURNOUT APPLICATIONS

    M/W ROADMASTER & SIGNAL MAINTAINER OFFICE

    BR-101

    STEEL BEAM SPAN WITH CONCRETE DECK

    STEEL DECK PLATE GIRDER SPAN WITH CONCRETE DECK

    PRE-STRESSED PRE-CAST CONCRETE BOX GIRDER SPAN

    WITH OR WITHOUT CONCRETE DECK

    BR-102

    BR-103

    BR-104

    BR-105

    PRE-STRESSED PRE-CAST AASHTO-TYPE BEAM SPAN

    WITH CONCRETE DECK

    CAST-IN PLACE CONCRETE BOX GIRDER SPAN

    CONVENTIONAL REINFORCED

    BR-106

    BR-107

    BR-108

    BR-109

    CAST-IN PLACE POST-TENSIONED CONCRETE BOX GIRDER SPAN

    STEEL THROUGH PLATE GIRDER SPAN WITH CONCRETE DECK

    STEEL THROUGH PLATE GIRDER SPAN WITH STEEL DECK

    CHAIN LINK RAILING DETAILS

    TUBULAR HAND RAILING DETAILS

    PICKET HAND RAILING DETAILS

    DECK DRAIN DETAILS

    FLASHING DETAILS FOR WATER-PROOFING

    WATER-PROOFING DETAILS

    COLLISION IMPACT DEVICES AND SACRIFICAL BEAM

    TRACK SHIELD DETAIL

    FRAME PROTECTION DETAILS BRIDGE DECK ELEVATIONS

    FRAME PROTECTION DETAILS BRIDGE DECK CROSS SECTION

    BONDING DETAILS FOR MULTIPLE PRE-STRESSED

    PRE-CAST CONCRETE GIRDERS

    BR-110

    BR-111

    BR-112

    BR-113

    BR-114

    BR-115

    BR-116

    BR-117

    BR-118

    BR-119

    BR-120

    BR-121

    BARRIERS AND CLEARANCES TO BE PROVIDED AT HIGHWAY,

    STREET AND PEDESTRAIN OVERPASSES

    BARRIERS FENCES AND SPLASHBOARDS TO BE PROVIDED AT

    HIGHWAY, STREET AND PEDESTRAIN OVERPASSES

    GENERAL INFORMATION

    BRIDGES

    G

    BR

    STANDARD PILE TRESTLE 5 PILE BENTS & BRACING

    STANDARD RAIL GIRDERS ON PILE BENTS

    TIMBER PILE TRESTLE TYPICAL COMPONENTS

    DECK FOR CREOSOTED PILE & FRAME TRESTLE 14 PANELS

    GENERAL SHORING REQUIREMENTSDOUBLE INSIDE GUARDRAIL

    BR-122

    BR-123

    BR-124

    BR-125

    BR-126

    BR-127

    BR-128

    RA-101

    RA-102

    RA-103

    STANDARD PILE TRESTLE 6 PILE BENTS & BRACING

    RAIL IDENTIFICATION

    BEVELING & CHAMFERING

    RAIL SECTIONS SHEET 1 OF 7

    CHART 1 FOR RAIL SECTIONS SHEET 2 OF 7

    CHART 2 FOR RAIL SECTIONS SHEET 3 OF 7

    CHART 3 FOR RAIL SECTIONS SHEET 4 OF 7

    CHART 4 FOR RAIL SECTIONS SHEET 5 OF 7

    CHART 5 FOR RAIL SECTIONS SHEET 6 OF 7

    CHART 6 FOR RAIL SECTIONS SHEET 7 OF 7

    RAIL WEAR LIMITS

    SPRING WASHER

    TRACK SPIKES AND SHIM SPIKES

    TIMBER SCREW SPIKE FOR ROAD CROSSING

    OVAL NECK TRACK BOLTS AND NUTS

    EPFLEX RAILSEAL

    RA-104

    RA-105

    RA-106

    RA-107

    RA-108

    RA-109

    RA-110

    RA-111

    RA-112

    RA-113

    RA-114

    RA-115

    OTM-101

    OTM-102

    OTM-103

    OTM-104

    OTM-105

    OTM-106

    OTM-107

    OTM-108

    OTM-109

    OTM-110

    OTM-111

    OTM-112

    HINGED FINGER LIFT DERAIL

    NOMENCLATURE FOR FROG GUARDRAIL

    PANDROL ROLLED STEEL TIE PLATE FOR WOOD TIES

    PANDROL PLATE PLACEMENT ON WOOD TIES

    PANDROL CLIP TYPE RP601A

    FROG BOLTS, NUTS AND HARDENED FLAT WASHERS

    SCREW SPIKE

    HI-RISE OPERATING STAND FOR USE WITH SLIDING DERAILS

    HOOK-IN SHOULDER PANDROL CLIP TYPE E-2055 ON STEEL TIES

    DRIVE ON ANCHOR TYPES

    DOUBLE JAWED NON-INSULATED GAGE ROD

    CURVE BLOCK ASSEMBLY OF DOUBLE SHOULDER TIE PLATE

    FOR 5 12" BASE RAIL

    RAIL

    OTHER TRACK MATERIALOTM

    RA

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • DWG No. DRAWING TITLE DWG No. DRAWING TITLE

    4-27-07

    NONE

    RGT

    4-27-07INDEX OF DRAWINGS

    INDEX 2

    OTM-113

    OTM-114

    OTM-115

    DOUBLE JAWED INSULATED GAGE ROD

    PREFABRICATED MTRE CUT BONDED INSULATED JOINT

    TRACK MATERIAL TABLE

    SOLID MANGANESE SELF GUARDED FROG

    COMPROMISE JOINT ORDERING REQUIREMENTS

    CONCRETE TIE ASSEMBLY TO SUIT 136RE RAIL

    RETRO FIT FROG PLATES FOR AREMA TURNOUTS

    METHOD OF ANCHORING CWE W/ANNUAL TONNAGE

    GREATER OR EQUAL TO 10 MGTOTM-116 METHOD OF ANCHORING CWE W/ANNUAL TONNAGE

    LESS THAN 10 MGT

    OTM-117

    OTM-118

    OTM-119

    OTM-120

    OTM-121

    OTM-122

    OTM-123

    DRIFT PIN

    CONCRETE TIE RAIL PAD DETAIL

    HEAVY DUTY INSULATOR TYPE HD-8 w/STEPPED DEEP SIDE POST

    CAST SHOULDER TO SUIT PANDROL BRAND RAIL CLIPS

    TYPE E20119-AV

    OTM-124

    OTM-125

    RB ROAD BED

    RB-100 BALLAST & GRADATION PROPERTIES

    BALLAST GRADATION TABLE

    TYPICAL FINISHED GRADING AND BALLAST SECTION

    12" BALLAST SECTION FOR MAIN TRACK

    CASING PIPE INSTALLATION

    TYPICAL SECTIONS AT ABUTMANT SLOPE

    RB-101

    RB-201

    RB-202

    RB-203

    RB-204

    RB-205

    RB-206

    RB-207

    RB-208

    TYPICAL FINISHED GRADING AND BALLAST SECTION

    FOR INDUSTRIAL TRACKS IN MISSOURI

    RB-301

    RB-302

    RB-303

    RB-304 TYPICAL STAKES SET DURING CONSTRUCTION OF THE TURNOUT

    ROADBED SECTIONS FOR WOOD TIE CONSTRUCTION

    (NEW CONSTRUCTION)

    TYPICAL FINISHED GRADING AND BALLAST SECTION

    FOR INDUSTRIAL TRACKS (NEW CONSTRUCTION)

    TYPICAL WALKWAY/ROADBED AT SWITCH STAND

    (NEW CONSTRUCTION)

    TABLE No. 1 TRACKS TO SERVE INDUSTRIES (NEW CONSTRUCTION)TYPICAL LAYOUT FOR INDUSTRY TRACK PARALLEL

    TO MAIN/LEAD TRACK

    TYPICAL LAYOUT FOR INDUSTRY TRACK PERPENDICULAR

    TO MAIN/LEAD TRACK

    RB-305

    RB-306

    RIGHT OF WAY FENCE

    RETAINING WALL DETAILS

    SPIKE PATTERNS FOR TANGENT AND CURVED TRACK

    PRECAST REINFORCED CONCRETE CROSSING

    DESIGN CLEARANCES FOR HIGHWAY

    STANDARD CLEARANCES FOR NEW INSTALLATIONS

    CLEARANCE REQUIREMENTSWIRE LINE CLEARANCE CHART

    CURVE MARKINGS

    SUPERELEVATION OF CURVES 1" UNBALANCED

    SUPERELEVATION OF CURVES 1 1/2" UNBALANCED

    SUPERELEVATION OF CURVES 2" UNBALANCED

    SUPERELEVATION OF CURVES 3" UNBALANCED

    VERTICAL CURVE DESIGN

    CHANGE OF SUPERELEVATION DISTANCE

    PREFABRICATED SECTIONAL TREATED TIMBER ROAD CROSSING

    TYPICAL LOCATION OF SLOPE STAKES DURING CONSTRUCTION

    OF THE ROADBED

    RB-401

    RB-402

    RB-501

    RB-601

    RB-602

    RB-603

    RB-701

    RB-702

    RB-703

    RB-704

    RB-801

    RB-802

    RB-803

    STANDARD EARTH BUMPER (NEW CONSTRUCTION)

    DERAIL INSTALLATION INSTRUCTIONS (NEW CONSTRUCTION)

    RB-804

    RB-805

    RB-806

    RB-807

    S-101

    S SIGNS

    STOP SIGN

    SIGN POST

    SPEED LIMIT SIGN

    STANDARD SIGNS

    NO TRESPASSING SIGN

    "X" BOARD SIGN

    S-102

    S-103

    S-104

    S-105

    S-106

    S-107

    S-108

    S-109

    S-110

    S-111

    S-112

    S-113

    TOP OF RAIL MARKER

    SIGN USED IN CONJUNCTION WITH FORM "A" ORDERS

    ON MAIN TRACK

    SIGN USED IN CONJUNCTION WITH FORM "B" ORDERS

    ON MAIN TRACK

    YARD LEAD SWITCH STAND TARGET, STEEL SQUARE TUBINGAND ASSEMBLY

    RAILROAD PUBLIC GRADE CROSSING SIGN

    SPEED BUMP SIGN

    SPEED RESTRICTION SIGN (MAINTENANCE ONLY)APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • DWG No. DRAWING TITLE DWG No. DRAWING TITLE

    4-27-07

    NONE

    RGT

    4-27-07INDEX OF DRAWINGS

    INDEX 3

    S-114

    MILE POST SIGN

    STRUCTURE WILL NOT CLEAR SIGN

    CONTROL POINT SIGN

    NUMBERS AND LETTERS

    SIGNAL BERMS

    PRIVATE ROAD SIGN

    PRIVATE ROADWAY GRADE CROSSING SIGN (NEW INSTALLATION)

    S-115

    S-116

    S-117

    S-118

    S-119

    S-120

    S-121

    S-122

    S-123

    TO-101

    EMERGENCY SIGN

    NO TRAIN HORN WILL BLOW SIGN

    ROADWAY HIGHWAY CROSSING SIGN

    TURNOUT NOMENCLATURE

    TURNOUT GEOMETRY FOR INDUSTRIAL TRACKS

    DATA FOR CROSSOVERS

    SWITCH STAND TYPE & PLACEMENT

    SWITCH STAND MOUNTING DETAILS

    SWITCH POINT CLAMP

    RAILBOUND MANGANESE FROG PREFERRED NOMENCLATURE

    No. 7 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 8 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 9 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 10 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 11 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 12 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 14 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 15 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 16 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    No. 20 TURNOUT GEOMETRY & SWITCH TIE LAYOUT

    BILL OF SWITCHES

    TURNOUT DATA

    GUARDRAIL PLACEMENT

    SWITCH POINT DETAILS

    BENDING STOCK RAIL

    TO TURNOUTS

    TO-102

    TO-103

    TO-104

    TO-105

    TO-106

    TO-107

    TO-108

    TO-109

    TO-110

    TO-111

    TO-112

    TO-113

    FACING POINT TURNOUT ARRANGEMENT (NEW CONSTRUCTION)

    TO-114

    TO-115

    TO-116

    TO-117

    TO-118

    TO-119

    TO-120

    TO-121

    TO-122

    TO-123

    16-6" SWITCH POINT DERAIL FOR INSTALLATION

    MANUAL OPERATION

    TO-124

    RACOR 36E SWITCH STAND

    RACOR 22E SWITCH STAND

    RACOR 112E COLUMN SWITCH STAND

    SWITCH POINT LOCK AUTOMATIC)

    TO-125 DOUBLE SWITCH POINT DERAIL 16-6" STRAIGHT SAMSON SWITCH

    MANUAL OPERATED LAYOUT SIDE

    TO-126

    TO-127

    TO-128

    TO-129

    TO-130

    MANGANESE SWITCH POINT TIPS (MAINTENANCE ONLY)

    CROSSING FROGXF-101

    XF CROSSING FROG

    TO-131 SOLID MANGANESE STEEL FROGS

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    MULTIPLY MULTIPLYBY BYTO OBTAIN TO OBTAIN

    LE

    NG

    TH

    AR

    EA

    WEIG

    HT

    MO

    ME

    NT

    FO

    RC

    ES

    TR

    ESS

    VO

    LU

    ME

    INCHES (IN)

    FEET (FT)

    YARDS (YD)

    MILES (MI)

    SQUARE INCHES (IN)

    SQUARE FEET (FT)

    SQUARE YARDS (YD)

    ACRES (AC)

    SQUARE MILES (MI)

    OUNCES (OZ)

    POUNDS (LB)

    KIPS (K)

    TONS (TN)

    MO

    ME

    NT

    OF IN

    ER

    TIA

    TONNES (METRIC TON)

    25.4000

    0.3048

    0.9144

    1.6093

    645.1600

    0.0929

    0.8361

    0.4046

    2.5900

    28.3495

    0.4536

    0.4536

    0.9072

    1000.0000

    MILLIMETERS (MM)

    METERS (M)

    METERS (M)

    KILOMETERS (KM)

    SQUARE MILLIMETERS (MM)

    SQUARE METERS (M)

    SQUARE METERS (M)

    HECTARES (HA)

    SQUARE KILOMETERS (KM)

    GRAMS (G)

    KILOGRAMS (KG)

    TONNES (METRIC TON)

    TONNES (METRIC TON)

    KILOGRAMS (KG)

    KIP FEET (KIP FT)

    POUND INCHES (LB IN)

    POUND (LB) (FORCE)

    KIP (K)

    NEWTON (N)

    POUND/SQUARE IN (PSI)

    KIP/SQUARE IN (KSI)

    KIP/SQUARE FOOT (KSF)

    PASCAL (PA)

    CUBIC INCHES (IN)

    CUBIC FEET (FT)

    CUBIC YARDS (YD)

    IN 4

    4FT

    1.35582

    0.11298

    4.44820

    4.44820

    1.00000

    6.89480

    6.89480

    47.88030

    1.00000

    16387.06400

    0.02832

    0.76456

    416231.40000

    0.00863

    KILONEWTON METER (KNM)

    NEWTON METER (N M)

    NEWTON (N)

    KILONEWTON (KN)

    KG M/SEC

    KILOPASCAL (KPA)

    MEGAPASCAL (MPA)

    KILOPASCAL (KPA)

    N/M

    CUBIC MILLIMETERS (MM)

    CUBIC METERS (M)

    CUBIC METERS (M)

    MM4

    M4

    PREFIXES: U=10 , M=10 , K=10, M=10-6 -3 6

    3-5-02

    NONE

    DLL

    4-27-07 ENGLISH TO METRICCONVERSION CHART G-101

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    TANGENTLENGTH

    AS REQUIRED

    SHOE-FLY AROUND

    DIMENSION TABLE (IN FEET)

    WRECKS AND WASHOUTS

    MAIN LINE

    TEMPORARY LINE

    A A

    50 TANGENT50 TANGENT

    E

    F

    H H

    F

    E

    D

    B

    C B

    C

    12 B

    12 B

    CURVE

    CURVE

    D

    B

    C

    C

    12 B

    12 B

    B

    CURVE

    CURVE

    4-21-06

    NONE

    RGT

    4-27-07 TEMPORARY TRACKAROUND OBSTRUCTIONS G-105

  • TRACK CLASS

    NOTES:

    1. WHEN TRACK IS BEING REALIGNED DUE TO SLEEDING, UNDERCUTTING OR SIMILAR MAINTENANCE OPERATIONS, TANGENTS BETWEEN CURVES SHOULD BE ADJUSTED WHERE PRACTICAL.

    2. DO NOT INSTALL NEW TURNOUTS OR RELAY WITH SWITCH PANELS TURNOUTS WITHIN 200 FEET OF A CURVE WITHOUT THE AUTHORIZATION OF THE CHIEF ENGINEER.

    T FORNEW CONSTRUCTION

    FRA CLASS 4 500 FT

    FRA CLASS 3 250 FT

    FRA CLASS 2 150 FT

    FRA CLASS 1 60 FT

    PS

    T

    PT

    S

    T = MINIMUM TANGENT DISTANCE

    5-30-06

    NONE

    RGT

    4-27-07MINIMUM TANGENT DISTANCE G-106

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    A/C UNIT

    A/C UNIT

    A/C UNIT

    ROADMASTER OFFICE SIGNAL MAINTAINER OFFICEM/W OFFICE

    RESTROOM

    A/C UNIT A/C UNIT

    A/C UNIT

    A/C PLUG A/C PLUG

    A/C PLUG

    G.F.I. @ 42"

    3-0 x 4-0 3-0 x 4-0 3-0 x 4-0

    3-0 x 4-0 3-0 x 4-0

    3-0

    x

    4-0

    3-0

    x

    4-0

    SS

    SS

    VENT/FAN

    SS

    S

    150W FLOOD 150W FLOODWP PLUG WP PLUG

    WP PLUG WP PLUG

    PO

    WE

    R

    PA

    NE

    L

    INSTALL (2) 3" CONDUITS

    PULL PHONE THROUGH ONE CONDUIT

    PULL DATA THROUGH OTHER CONDUIT

    LEAVE 8 TAILS AND LABLE CABLES

    HOSE BIB

    3

    x

    3

    MIR

    RO

    W3

    x

    3

    MIR

    RO

    W

    HOSE BIB

    TOWELHOLDER

    SIN

    K

    200 AMP. SERVICE

    30 - 68 30 - 68

    30 -

    68

    30 -

    68

    30 -

    68

    10 GAL. ELEC. WATER HEATER

    NOTES:1. BUILD MODULAR BUILDING ON TRAILER W/AXLES AND WHEELS2. INSTALL 26GAUGE METAL ON WALLS AND ROOF.3. INSTALL (2) EXTERIOR GRADE SOLID METAL DOORS.4. INSTALL (7) DOUBLE INSULATED SINGLE HUNG WINDOWS.5. INSTALL (2) SETS OF TREATED STEPS W/HANDRAILS.6. INSTALL 200 AMP SERVICE AND BREAKER PANEL.7. INSTALL (3) CARRIER XHA123D WINDOW UNITS W/HEAT STRIPS.8. INSTALL 2 LAYERS OF 3/4" PLYWOOD SUB-FLOORING.9. INSTALL 1/2" SHEETROCK AND PANELING OVER TOP.10. INSTALL VCT TILE ON FLOOR W/VINYLE BASE.11. INSTALL 1/2" MIMI BLINDS ON ALL WINDOWS. 12. INSTALL SCHLEDGE LOCKS ON ALL DOORS.13. INSTALL (2) KCS LOGO SIGNS.14. INSTALL R13 INSULATION IN WALLS.15. INSTALL R19 INSULATION IN CEILING.16. INSTALL PLYWOOD CEILING AND PAINT.17. INSTALL DOOR CLOSURES ON EXTERIOR DOORS.18. INSTALL CAT5 DATA CABLES AND PHONE LINES.19. BLOCK AND LEVEL BUILDING.20. INSTALL TIE DOWN STRAPS.

    5-312" 17-1014" 11-6

    34" 5-3

    12"

    40

    6-

    21 2"

    5-

    91 2"

    12

    5-312" 11-812" 7-11"

    9-912" 5-312"

    10-3 12" 6-312" 12-10" 10-7"

    2-

    31 2"

    9-

    81 2"

    4-312" 2-312"

    2-

    31 2"

    9-

    81 2"

    6-

    7"

    6

    4

    4

    6-

    21 2"

    5-

    91 2"

    4-11-02

    NONE

    DLL

    4-27-07 M/W ROADMASTER & SIGNAL MAINTAINEROFFICE G-108

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    CONCRETE DECK

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    DRIPGROVE

    1"

    MI

    N.

    VA

    RI

    ES

    DECK PLATE GIRDER WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALESTEEL DECK PLATE GIRDERS WITH CONCRETE DECK

    1-27-05

    NONE

    RGT

    4-27-07 STEEL DECK PLATE GIRDER SPANWITH CONCRETE DECK BR-101

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    CONCRETE DECK

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    DRIPGROVEV

    ARI

    ES

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    BEAM DIAPRAGM (TYP.)

    1"

    MI

    N.

    NO SCALESTEEL BEAMS WITH CONCRETE DECK

    1-27-05

    NONE

    RGT

    4-27-07 STEEL BEAM SPANWITH CONCRETE DECK BR-102

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    DRIPGROVEV

    ARI

    ES

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    * CONCRETE DECK

    NO SCALEPRECAST CONCRETE BOX GIRDERS WITH CAST IN PLACE CONCRETE DECK

    PRESTRESSEDCONCRETEBOX GIRDER

    DRIPGROVE

    TRANSVERSE TIE ROD

    FLEXIBLE SEALING STRIP

    * CONCRETE DECK IS OPTIONAL

    KEYWAY FILLED WITH EPOXYOR FLOWABLE GROUT (TYP.)SEE DRAWING 005090

    1-27-05

    NONE

    RGT

    4-27-07PRE-STRESSED PRE-CAST

    CONCRETE BOX GIRDER SPANWITH OR WITHOUT CONCRETE DECK BR-103

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    DRIPGROVE

    VA

    RI

    ES

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALE

    PRESTRESSEDCONCRETEGIRDER

    DIAPRAGM

    PRECAST CONCRETE BEAMS WITH CAST IN PLACE CONCRETE DECK

    CONCRETE DECK

    1-27-05

    NONE

    RGT

    4-27-07PRE-STRESSED PRE-CASTAASHTO-TYPE BEAM SPAN

    WITH CONCRETE DECK BR-104

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    VA

    RI

    ES

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALE

    DRIPGROVE

    CONVENTIONAL REINFORCED CONCRETE BOX GIRDERS

    CAST IN PLACECONCRETE BOX GIRDER

    1-27-05

    NONE

    RGT

    4-27-07CAST-IN PLACE

    CONCRETE BOX GIRDER SPANCONVENTIONAL REINFORCED BR-105

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    DRAIN PIPE (TYP.)

    2-0"

    MI

    N.

    CENTER LINE OF EXIST. TRACK

    RAILING ORCHAIN LINK FENCE

    TOP OF RAIL

    9-0" MIN.(TANGENT TRACK)

    9-6" MIN.(CURVED TRACK)

    6-0" MIN.16-0" MIN.20-0" MIN.

    BALLAST

    CENTER LINE OF EXIST. ORFUTURE TRACK

    CENTER LINE OF ACCESS ROAD

    A.C. PAVEMENT

    1% SLOPE

    2-0"

    1-0"

    6"

    MI

    N.

    2-6"

    MI

    N.

    MIN. 1%

    SLOPE

    MIN. 1%

    SLOPE

    VA

    RI

    ES

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALE

    DRIPGROVE

    POST-TENSIONED CONCRETE BOX GIRDERS

    POST-TENSIONEDCONCRETE BOX GIRDER

    1-27-05

    NONE

    RGT

    4-27-07 CAST-IN PLACE POST-TENSIONEDCONCRETE BOX GIRDER BR-106

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • CENTER LINE OF EXIST. ORFUTURE TRACK

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALESTEEL THROUGH PLATE GIRDERS WITH CONCRETE DECK

    1-0"

    1-0"

    A.C. PAVEMENT

    1% SLOPE

    GUARD RAIL

    CENTER LINE OF ACCESS ROAD

    6-0" MIN.

    5-0"MIN.

    SEPARATION

    2-0"

    MI

    N.TOP OF

    RAIL

    6-6" MIN.

    6-0"

    4-0"

    CENTER LINE OF EXIST. TRACK

    20-0" MIN.

    DRAIN PIPE (TYP.)

    8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    *

    STANDARD AREACLEARANCE ENVELOPE

    SLOPE 1:2.8 PREFERED

    1:3 MAX.

    SEE DETAIL A

    CHECKEREDPLATEWALKWAY

    2-0"

    VA

    RI

    ES

    2-6"MIN.

    DIAPRAGM

    STEEL FLOOR BEAM

    CONCRETE DECK

    SEPARATE MAINTENANCEOF WAY ROADWAY STRUCTURE

    STEEL THROUGHPLATE GIRDER

    DETAIL A

    " MAX.

    CHECKEREDPLATEWALKWAY

    STIFF.

    SUPPORT WALKWAY ONKNEE BRACE OR STIFF.

    SLOPE 2%

    12"

    WATERPROOFING

    CONC. CURB

    KNEE BRACE

    * NOTE:

    9-0" MIN. (TANGENT TRACK)FOR CURVE TRACK REFER TO AREMA

    1-27-05

    NONE

    RGT

    4-27-07 STEEL THROUGH PLATER SPANWITH CONCRETE DECK BR-107

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • CENTER LINE OF EXIST. ORFUTURE TRACK

    WATERPROOFING(BUTYL MEMBRANE OR EPDM AND TWOLAYERS OF ASPHALTIC PROTECTIVE PANELS)

    NO SCALE

    1-0"

    1-0"

    A.C. PAVEMENT

    1% SLOPE

    GUARD RAIL

    CENTER LINE OF ACCESS ROAD

    6-0" MIN.

    5-0"MIN.

    SEPARATION

    2-0"

    MI

    N.TOP OF

    RAIL

    6-6" MIN.

    6-0"

    4-0"

    CENTER LINE OF EXIST. TRACK

    20-0" MIN.

    DRAIN PIPE (TYP.)

    8" MIN. BALLASTUNDER TIMBER TIE OR12" MIN. BALLASTUNDER CONCRETE TIE

    *

    STANDARD AREACLEARANCE ENVELOPE

    SLOPE 1:2.8 PREFERED

    1:3 MAX.

    SEE DETAIL A

    CHECKEREDPLATEWALKWAY

    2-0"

    VA

    RI

    ES

    2-6"MIN.

    DIAPRAGM

    STEEL FLOOR BEAMSEPARATE MAINTENANCE

    OF WAY ROADWAY STRUCTURE

    STEEL THROUGHPLATE GIRDER

    DETAIL A

    " MAX.

    CHECKEREDPLATEWALKWAY

    STIFF.

    SUPPORT WALKWAY ONKNEE BRACE OR STIFF.

    SLOPE 2%

    12"

    WATERPROOFING

    CONC. CURB

    KNEE BRACE

    STEEL THROUGH PLATE GIRDERS WITH STEEL DECK

    STEEL DECK

    * NOTE:

    9-0" MIN. (TANGENT TRACK)FOR CURVE TRACK REFER TO AREMA

    1-27-05

    NONE

    RGT

    4-27-07 STEEL THROUGH PLATE GIRDER SPANWITH STEEL DECK BR-108

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • RAILING OR FENCE

    6"

    CURB

    FLASHING

    WATERPROOFING

    CONCRETE DECK

    KEYWAY FILLEDWITH EPOXYOR NON SHRINKCEMENTITIOUSFLOWABLE GROUT(TYP.)

    TRANSVERSETIE RODGALVANIZED ORGROUTED

    FLEXIBLE SEALINGSTRIP (TYP.)

    END BLOCK ORINTERIOR DIAPRAGM

    FILL WITH NON SHRINKCEMENTITIOUS GROUT FLUSH

    WITH GIRDER AFTERSTRESSING TIE RODS

    PRECAST CONCRETEBOX GIRDER

    NO SCALE

    MULTIPLE PRESTRESSEDCONCRETE GIRDER BONDING DETAIL

    PROCEDURE FOR GROUTING BETWEEN GIRDERS(EPOXY GROUT)

    1. BEFORE SETTING GIRDERS, THOROUGHLY WIRE BRUSH THE

    ENTIRE CONTACT SURFACES OF EACH GIRDER.

    2. INSTALL 2 LAYERS OF 3" x 4" FLEXIBLE SEALING STRIPS

    (POLY-URETHANE-ETHER TYPE DENSITY 1.5) AT THE BOTTOM OF THE GAP AND AROUND TIE ROD HOLES AND ENDS OF

    GIRDERS TO PREVENT GROUT LEAKAGE. THE MAXIMUM GAP BETWEEN

    GIRDERS SHOULD BE ".

    3. INSTALL TIE RODS AND TENSION 50%.

    4. PLACE 4" SAND ON TOP OF SEALING STRIPS

    TO PROTECT SEALING STRIPS FROM EPOXY HEAT.

    5. FILL THE GAP WITH DRY CLEAN PEA GRAVEL (1/2" MAXIMUM SIZE). IN COLD WEATHER, HEAT THE PEA GRAVEL.

    6. POUR EPOXY GROUT TO FILL ALL VOIDS IN GAP.

    THIS MAY TAKE 2 TO 3 SUCCESSIVE POURINGS.

    7. TENSION TIE RODS 100%.

    PROCEDURE FOR GROUTING BETWEEN GIRDERS(NON SHRINK CEMENTITIOUS FLOWABLE GROUT

    1. BEFORE SETTING GIRDERS, THOROUGHLY WIRE BRUSH THE

    ENTIRE CONTACT SURFACES OF EACH GIRDER.

    2. INSTALL 2 LAYERS OF 3" x 4" FLEXIBLE SEALING STRIPS

    (POLY-URETHANE-ETHER TYPE DENSITY 1.5) AT THE BOTTOM OF THE GAP AND AROUND TIE ROD HOLES AND ENDS OF

    GIRDERS TO PREVENT GROUT LEAKAGE. THE MAXIMUM GAP BETWEEN

    GIRDERS SHOULD BE ".

    3. INSTALL TIE RODS AND TENSION 50%.

    4. PLACE FLOWABLE NON SHRINK CEMENTITIOUS GROUT BETWEEN GIRDERS.

    (GROUT TO BE MIXED TO A POURABLE CONSISTENCY. THE MATERIAL SHALL BE MIXED TO A COMBINATION BETWEEN FLOWABLE

    AND FLUID SO AS NOT TO FORM AIR POCKETS BETWEEN GIRDERS

    WHILE BEING POURED).

    5. AFTER GROUT HAS REACHED A COMPRESSIVE STRENGTH OF 3000 P.S.I.,

    TENSION TIE RODS 100%.

    1-27-05

    NONE

    RGT

    4-27-07BONDING DETAILS FOR MULTIPLE

    PRE-STRESSED PRE-CASTCONCRETE GIRDERS BR-109

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NO SCALE

    POST ANCHORAGE DETAILNO SCALE

    NOTES:

    1. RAILING ASSEMBLY EXCEPT CHAIN LINK FABRIC TO BE

    GALVANIZED AFTER FABRICATION.

    2. POSTS SHALL BE VERTICAL.

    3. PROVIDE HARDWARE AND DETAILS FOR ATTACHMENTS TO

    CABLE, POSTS, AND TOP RAILING.

    4. PROVIDE SPLICE AND EXPANSION JOINT DETAILS.

    NO SCALE

    TYPICAL SECTION

    CHAIN LINK RAILING

    CONCRETE BARRIER

    TOP OF WALKWAY

    1"

    6"

    CL POST

    6"

    FILL WITH MORTAR

    5"

    8"

    8"

    #4 TIE (2 REQD.)

    #4 BAR (4 REQD.)(ONE EACH CORNER)

    1"

    8"

    RAILING ELEVATION

    6-0" WIDE, CHAIN LINKFABRIC 1" MESH.

    KNUCKLED SELVAGE TOPAND BOTTOM

    TS 3x2x.1875(TYP. ALL POSTS)

    " GALVANIZED CABLE THREADED THROUGH" DIA. HOLES IN INTERMEDIATE POSTS

    9" MIN. ATWALL JOINT

    1-0" AT SPLICEOR EXP. JOINT

    9" 5-0" MIN.

    10-0" MAX.

    L 4x3x LLH

    1-27-05

    NONE

    RGT

    4-27-07CHAIN LINK RAILING DETAILS

    BR-110

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • POST ANCHORAGE DETAILNO SCALE

    NO SCALE

    TYPICAL SECTION

    CONCRETE BARRIER

    TOP OF WALKWAY

    1"

    6"

    CL POST

    6"

    FILL WITH MORTAR

    5"

    8"

    8"

    #4 TIE (2 REQD.)

    #4 BAR (4 REQD.)(ONE EACH CORNER)

    1"

    8"

    NOTES:

    1. GALVANIZE RAIL ASSEMBLY AFTER FABRICATION.

    2. POSTS SHALL BE VERTICAL.

    3. PROVIDE RAILING CONNECTION DETAILS.

    4. PROVIDE SPLICE AND EXPANSION JOINT DETAILS.

    TUBULAR HAND RAILING

    3-6"

    RAILING ELEVATION(FOR USE IN RURAL LOCATIONS)

    NO SCALE

    9" MIN. ATDECK OR WALLJOINT

    1-6"

    TS 2x2x.1875(TYP. ALL POSTS)

    * WHEN ADJACENT TO DECK OR WALL JOINT* 3-0" MIN.

    * 8-0" MAX.

    TS 3x2x.1875 TS 2x2x.1875

    10-0" MAX.

    3-3" 5-0" MIN.

    CL SPLICE1"

    "

    MA

    X.

    4

    -

    0"

    RA

    D

    .

    1-27-05

    NONE

    RGT

    4-27-07TUBULAR HAND RAILING DETAILS

    BR-111

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NO SCALE

    TYPICAL SECTION

    CONCRETE BARRIER

    TOP OF WALKWAY

    1"

    6"

    CL6"

    8"

    NOTES:

    1. GALVANIZE RAIL ASSEMBLY AFTER FABRICATION.

    2. POSTS SHALL BE VERTICAL.

    3. PROVIDE RAILING CONNECTION DETAILS.

    4. PROVIDE SPLICE AND EXPANSION JOINT DETAILS.

    TUBULAR HAND RAILING

    3-0"

    RAILING ELEVATION(FOR USE IN RURAL LOCATIONS)

    NO SCALEPOST (WELD TO BASE PLATE)

    2"

    "

    GR

    OU

    T

    BASE PLATE "x 6"x 0-6"

    WITH 4-" DIA. HOLES. DISTANCE

    FROM CENTER OF HOLE TO EDGE TO BE 1"

    " x 6"x 0-6" (A36) WITH

    2" DIA. HOLE CTRD. & 4-"

    THRD. RODS (A307) WITH 2-HEX NUTS

    & 1 FLAT WASHER. WELD RODS TO PLATE

    6"

    4"

    6" MAX. (CENTER TO CENTEROF PICKETS, TYP.)

    2" DIA. SCH. 40 PIPE7" MAX. (CENTER OF POST TO

    CENTER OF PICKET, TYP.)

    " DIA. ROD (TYP.)

    8"

    RAD.

    8"

    1-4"

    3" DIA. SCH. 80 PIPE

    8-0" MAX. 4-0" MAX.

    CL SPLICE

    4-0" MAX. 8-0" MAX. 4-0" MAX.

    2" " DIA. SCH. 80 PIPE(TYP. ALL POSTS)

    END PANEL INTERMEDIATE PANEL

    1-27-05

    NONE

    RGT

    4-27-07PICKET HAND RAILING DETAILS

    BR-112

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NO SCALEDETAIL - DRAIN PIPE

    DRAIN PIPE (TYP.)

    NO SCALETYPICAL DECK SECTION

    1

    "

    1

    "

    CL DRAINCL SLOTS

    8"

    SECTION A-A

    A

    A

    8-" x" SLOTS SPACEDON 2- 2/3 IN. CENTERS

    " "2-0"

    8-" x" SLOTS SPACEDON 2- 2/3 IN. CENTERS

    4"

    NO SCALEDETAIL - BOTTOM PLAN

    ON 2- 2/3 IN. SPACING

    TO STORM DRAIN

    45 - " x" SLOTS1-1/3" 1-1/3" 9"

    1"

    10-0"

    .064 THICK GALV. SHEET METAL

    6" DIA. DRAINPIPE DOWN SPOUT(AT END SECTIONS ONLY)

    NO SCALELOCATION OF DRAIN PIPE

    NOTE: LAP DRAIN PIPE ONE

    CORRUGATION AT EACH END.

    1-6"

    5"CURB

    BALLAST

    DRAIN PIPE

    BOTTOM PAN

    WATERPROOFING

    CL TRACK

    CL TRACK

    SLOPESLOPE

    NO SCALEDECK PLAN

    ABUTMENT ABUTMENTCONNECT DRAIN PIPES TODOWNSPOUTS AND UNDERDRAINS (TYP.)

    PIER DRAIN PIPE

    1-27-05

    NONE

    RGT

    4-27-07DECK DRAIN DETAILS

    BR-113

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NO SCALE

    NO SCALEFLASHING DETAIL

    LONG SLOTTED HOLE @

    2-0" MAX. CENTERS FOR

    " DIA. A-325 BOLT

    CL

    1

    "1

    "

    10"

    7"

    1"

    1"

    PL" STEEL

    (A36, GALV.)

    NOTES:

    1. ALL STRUCTURAL STEEL PLATES, BOLTS AND WASHERS SHALL BE GALVANIZED.

    2. DISCONTINUE FLASHING OVER PIERS AND ABUTMENTS.

    ALTERNATIVE 1

    1-6"

    BUTYL RUBBER

    MEMBRANE OR EPDM

    0.06" MINIMUM

    THICKNESS

    INSERT ASSEMBLY

    FOR" DIA. x 2"

    A-325 BOLT

    CONCRETE CURB SEE FLASHING DETAIL

    SEALANT

    BALLAST

    " DIA. x 2" A-325 BOLTWITH WASHER & LONG SLOTTEDHOLE @ 2-0" MAX. CENTERS

    TWO LAYERS OFPROTECTIVEASPHALTIC PANELS." TOTAL THICKNESSMINIMUM

    CONCRETE DECK

    1-6"

    BUTYL RUBBER

    MEMBRANE OR EPDM

    0.06" MINIMUM

    THICKNESS

    INSERT ASSEMBLY

    FOR" DIA. x 2"

    A-325 BOLT

    CONCRETE CURB

    SEALANT

    BALLAST

    " DIA. x 2" A-325 BOLTWITH WASHER & LONG SLOTTEDHOLE @ 2-0" MAX. CENTERS

    CONCRETE DECK

    NO SCALEALTERNATIVE 2

    SEE FLASHING DETAIL

    TWO LAYERS OFPROTECTIVEASPHALTIC PANELS." TOTALTHICKNESS MINIMUM

    1-27-05

    NONE

    RGT

    4-27-07FLASHING DETAILS FOR WATER-PROOFING

    BR-114

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NO SCALE

    BUTYL RUBBER MEMBRANE OR EPDMWATERPROOFING SPLICE DETAIL

    6" 6"

    .06

    0" (

    TY

    P.)

    TOUNGE & GROOVE - FIELD SPLICE

    BUTYL GUM TAPEEXTENDED"MIN. BEYONDEDGE OF SPLICE

    BUTYL GUM TAPEEXTENDED"

    MIN. BEYONDEDGE OF SPLICE

    NO SCALE

    TYPICAL TRANSVERSE SECTIONAT OPEN JOINT

    " MIN. OVERALL ASPHALT

    PROTECTIVE COVER SHEETS

    0.060 IN. BUTYL RUBBER

    MEMBRANE OR EPDM WATERPROOFING

    SEE FLASHING DETAILDWG. NO. 14

    28" WIDE x 0.060 IN. BUTYL RUBBERMEMBRANE OR EPDM WATERPROOFINGCENTERED OVER THE OPEN JOINT

    22" WIDE x 16 GAGE GALV. SHEET METALCOVER PLATE CENTERED OVERTHE OPEN JOINT

    " x 10" WIDE COVER PLATE(ON DECK & CURBE SLOTS)

    FACE OF CONCRETEAT OPEN JOINT

    NO SCALE

    TYPICAL LONGITUDINAL SECTIONAT CONTROLLED JOINT

    " MIN. OVERALL ASPHALT

    PROTECTIVE COVER SHEETS

    0.060 IN. BUTYL RUBBER

    MEMBRANE OR EPDM

    WATERPROOFING

    18" WIDE x 0.060 IN. BUTYL RUBBER

    MEMBRANE OR EPDM WATERPROOFING

    CENTERED OVER THE CONST. JOINT

    12" WIDE x 16 GAGE GALV. SHEET METAL

    COVER PLATE CENTERED OVER

    THE CONST. JOINT

    CL CONTROLLED JOINT

    SLAB

    NO SCALE

    TYPICAL LONGITUDINAL SECTIONAT CONTROLLED JOINT

    " MIN. OVERALL ASPHALT

    PROTECTIVE COVER SHEETS

    0.060 IN. BUTYL RUBBER

    MEMBRANE OR EPDM

    WATERPROOFING

    CL

    SLAB

    28" WIDE x 0.060 IN. BUTYL

    RUBBER MEMBRANE OR EPDM

    WATERPROOFING CENTERED OVER

    THE OPEN JOINT

    22" WIDE x 16 GAGE GALV.

    SHEET METAL COVER PLATE

    CENTERED OVER THE OPEN JOINT

    OPEN JOINT

    " x 10" WIDE

    COVER PLATE

    (ON DECK &CURB SLOTS)

    NO SCALE

    TYPICAL LONGITUDINAL SECTIONAT END OF BACKWALL / APPROACH SLABS

    " DIA. GALV. BOLT W/WASHER

    IN LONG SLOTTED HOLE

    SPACED AT 1-6" C. TO C.

    1-0"

    1-3"

    " x 13" WIDE ARMOR

    PLATE AT ABUTMENTS

    (FULL LENGTH OFWATERPROOFING)

    24" WIDE x 0.060 IN. BUTYL RUBBER

    MEMBRANE OR EPDM WATERPROOFING

    CENTERED ALONG THE AXIS OF THE

    CORNER

    BACKWALL OR

    APPROACH SLAB

    THREADED INSERT

    1-27-05

    NONE

    RGT

    4-27-07WATER-PROOFING DETAILS

    BR-115

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • TR

    AV

    EL

    LA

    NE

    S

    TR

    AV

    EL

    LA

    NE

    S

    SACRIFICIAL BEAM

    SACRIFICIAL BEAM A

    APIER

    ABUTMENT ABUTMENT

    CL TRACK

    PLAN

    ABUTMENT ABUTMENTROADWAY ROADWAY

    PIER CAP

    SACRIFICIAL BEAM

    *

    ELEVATION

    LAYOUT OF COLLISION IMPACT DEVICES & SACRIFITIAL BEAM* MIN. VERTICAL CLEARANCE REFER TO TEXT

    PIER

    TOP OF RAIL

    DETAIL B

    3"

    1"1"

    1

    "3"

    SLOTTED HOLE

    " SUPPORT BAR

    (GALV.)

    PROTECTIVE ANGLE

    (GALV.)

    SECTION A-A

    SECTION A-A

    (AT VERTICAL FACED GIRDER)

    (AT SLOPED FACED GIRDER)

    1"

    5-0"

    1

    "

    6"

    1" X 6"

    REDWOOD

    PLANK

    EXTERIOR

    GIRDER

    6" x 6" x"

    PROTECTION ANGLE

    (GALV.)

    FASTEN PROTECTION ANGLE

    TO GIRDER USING" DIA.

    BOLTS W/LOCK WASHER

    BOTTOM OF GIRDER

    SUPPORT BAR

    SEE DETAIL "B"

    PIER

    (BEYOND)

    SACRIFICIAL

    BEAM

    1"

    5-0"

    6"

    1" X 6"

    REDWOOD

    PLANK

    EXTERIOR

    GIRDER

    6" x 6" x"

    PROTECTION ANGLE

    (GALV.)

    FASTEN PROTECTION ANGLE

    TO GIRDER USING" DIA.

    BOLTS W/LOCK WASHER

    BOTTOM OF GIRDER

    SUPPORT BAR

    SEE DETAIL "B"

    PIER

    (BEYOND)

    SACRIFICIAL

    BEAM

    1-27-05

    NONE

    RGT

    4-27-07 COLLISION IMPACT DEVICESAND SACRIFICAL BEAM BR-116

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • CL TRACK

    5-0" MIN.5-0" MIN.

    TRACK SHIELD(SEE NOTES)

    TRACK

    TRIVIRA SPUNBOUND#45 GEOTEXTILE EACH

    SIDE OF TRACK(OR APPROVED EQUAL)

    TRACK SHIELD DETAILFOR DEBRIS FALLING FROM BRIDGE DECK REMOVAL

    (WHEN TRACK TIME WINDOW IS AVAILABLE)

    BLOCKING DETAIL

    BALLAST (SEE NOTES)

    LONGITUDINAL SUPPORTTEMBERS (TYP.)

    (SEE NOTES)

    2"

    TRACK SHIELD

    NOTES:

    1. A FLAGMAN IS REQUIRED AT ALL TIMES DURING THE USE OF A TRACK SHIELD.

    2. THE TRACK SHIELD SHALL BE DESIGNED BY THE CONTRACTOR AND SHALL BE OF SUFFICIENT STRENGTH TO SUPPORT THE ANTICIPATED LOADS, INCLUDONG IMPACT. THE SHIELD SHALL PREVENT ANY MATERIALS, EQUIPMENT OR DEBRIS FROM FALLING ONTO THE RAILROAD TRACK. ADDITIONAL LAYERS OF MATERIAL SHALL BE FURNISHED AS NECESSARY TO PREVENT FINE MATERIALS OR DEBRIS FROM SIFTING DOWN UPON THE TRACK.

    3. THE SHIELD SHOULD PREFERABLY BE PREFABRICATED AND FURNISHED WITH LIFTING HOOKS TO SIMPLFY REMOVAL.

    4. THE SHIELD SHALL BE OF SUFFICIENT STRENGTH TO SPAN BETWEEN ITS SUPPORT WITHOUT BEARING UPON THE RAILS AND TO WITHSTAND DROPPING RUBBLE.

    5. BEFORE REMOVAL, THE SHIELD SHALL BE CLEANED OF ALL DEBRIS AND FINE MATERIAL.

    6. THE TRACK SHIELD SHALL EXTAND AT LEAST 20 FEET BEYOND THE LIMITS OF DEMOLITION TRANSVERSE TO THE EDGE OF THE BRIDGE.

    ATTACKED TO THE SHIELD. REMANINIG TIMBERS SHALL BE ANCHORED.

    11. DETAILS SHOWN APPLY FOR TIMBER TIES. SPECIAL DETAILS ARE REQUIRED FOR CONCRETE TIES.

    THE SHIELD IE REMOVED. BLOCKING FROM THE TOP OF RAIL TO THE BOTTOM OF THE SHIELD MEY BE 7. LONGITUDINAL SUPPORT TIMBERS FOR THE SHIELD SHALL NOT EXTEND ABOVE THE TOP OF RAIL WHEN

    RAIL AND TO AN ELEVATION NO HIGHRT THAN THE TOP OF RAIL. 8. FOR TRAIN PASSAGE, THE RUBBLE SHALL BE REMOVED TO A MINIMUM OF 8-6" FROM THE NEAREST

    FROM THE NEAREST RAIL AND DOWN TO ORIGINAL GRADE. 9. AT THE END OF THE DAY, THE RUBBLE SHALL BE REMOVED COMPLETELY TO A MINIMUM OF 10-0"

    ARE SENT THROUGH THE RAILS AND WILL BE DISRUPTED BY A SHORT BETWEEN RAILS. 10. CARE SHALL BE TAKEN TO NOT PLACE METAL ACROSS THE TRACK RAILS. RAILROAD COMMUNICATIONS

    1-27-05

    NONE

    RGT

    4-27-07TRACK SHIELD DETAIL

    BR-117

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • CL TRACK4-0"(TYP.)

    4-0"

    (T

    YP.)

    CL TRACKLIMITS OF TRACK

    PROTECTION (TYP.)

    23-0"

    MI

    N.25-0"

    MIN.18-0"

    MIN.

    DEBRIS PROTECTION(TYP.) SEE NOTE 5

    BRIDGE ELEVATIONSTANDARD LIMITS OF PROTECTION FOR FRAME PROTECTION

    CL TRACK

    CL TRACK

    21-0"

    MI

    N.12-0"

    MIN.12-0"

    MIN.

    DEBRIS PROTECTION(TYP.) SEE NOTE 5

    BRIDGE ELEVATIONMINIMUM LIMITS OF PROTECTION FOR FRAME PROTECTION

    LIMITS OF TRACKPROTECTION (TYP.)

    TOP OF RAILACCESS ROAD

    TOP OF RAILACCESS ROAD *

    * IF NO ACCESS ROAD, USE MIN. DIMENSION FROM OTHER SIDE OF DETAIL.

    (SPECIAL PERMISSION REQUIRED, SEE NOTE 1)

    1. THE STANDARD LIMITS OF PROTECTION NOTED ARE THE MIN. CLEARANCES ALLOWED WITHOUT SPECIAL PERMISSION FROM THE RAILROAD. THE REDUCED CLEARANCES NOTED MAY BE ALLOWED BY THE RAILROAD. SPECIAL PERMISSION FOR THE REDUCED CLEARANCES IS REQUIRED FROM THE RAILROAD SERVICE UNIT SUPERINTENDENT.

    2. THE PROTECTION FRAME SHALL, AS A MINIMUM, MATCH THE DEMOLITION LIMITS SHOWN AND EXTEND PAST THE BRIDGE WIDTH AS SHOWN ON THE ATTACHED DEMOLITION SHEET.

    3. FOR ADDITIONAL CLEARANCE AND PROTECTION INFORMATION SEE STANDARD DRAWING NO. 005104.

    4. THE PROTECTION FRAME SHALL PREVENT DEMOLITION DEBRIS, DUST AND FINE MATERIAL FROM FALLING ONTO THE RAILROAD TRACKS, ACCESS ROADS OR TRAINS. THE FRAME SHALL BE DESIGNED BY THE CONTRACTOR TO SUPPORT THE ANTICIPATED DEMOLITION LOADS AND IN ACCORDANCE WITH AREMA GUIDELINES FOR DESIGN OF FALSEWORK FOR STRUCTURES OVER THE RAILROAD.

    5. DEBRIS PROTECTION IS REQUIRED NEAR THE BASE OF THE SIDE SLOPES AND ADJACENT TO ROADS USED BY DEMOLITION EQUIPMENT TO PREVENT DEBRIS FROM ROLLING ONTO THE TRACK, ACCESS ROAD OR DITCH. USE TIMBERS AS REQUIRED TO STOP LARGE PIECES OF ROLLING DEBRIS.

    6. ANY ACTIVITY WITHIN 25 FEET OF THE NEARAST RAIL OF A TRACK REQUIRES A FLAGMAN.

    1-27-05

    NONE

    RGT

    4-27-07 FRAME PROTECTION DETAILSBRIDGE DECK ELEVATIONS BR-118

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • NOTES:

    1. SEE GENERAL NOTES ON BRIDGE ELEVATION SHEET.

    2. STANDARD LIMITS OF PROTECTION ARE SHOWN. FOR MINIMUM LIMITS OF PROTECTION DIMENSIONS, SEE BRIDGE ELEVATION, MINIMUM LIMITS OF PROTECTION.

    18-0"MIN.

    (SEE NOTE 2)

    25-0"MIN.

    (SEE NOTE 2)

    10-0"

    10-0"ACCESS ROAD *

    BRIDGE DECK

    BRIDGE ELEVATIONSTANDARD LIMITS OF PROTECTION FOR FRAME PROTECTION

    * IF NO ACCESS ROAD, USE MIN. DIMENSION FROM OTHER SIDE OF DETAIL.

    BRIDGE DECK CROSS SECTIONSTANDARD LIMITS OF PROTECTION

    TOP OF RAIL

    EXTEND TO GRADE (TYP.)

    LIMITS OF PROTECTION (TYP.)

    10-0"MIN.

    10-0"MIN.

    BRIDGE DECK

    1-27-05

    NONE

    RGT

    4-27-07 FRAME PROTECTION DETAILSBRIDGE DECK CROSS SECTION BR-119

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • VIADUCT CROSS SECTIONWITH SPLASH BOARD AND FENCE

    FOR SNOW REMOVAL AREAS

    8

    MI

    N.

    5

    MI

    N.

    5

    MI

    N.

    10

    MI

    N.

    PEDESTRIAN WALKWAY

    SPLASHBOARDFENCE

    SPLASHBOARD

    BARRIER

    FENCE OR ORNAMENTAL RAILING

    8

    MI

    N.

    10

    MI

    N.

    PEDESTRIAN WALKWAY

    FENCE

    BARRIER

    VIADUCT CROSS SECTIONWITH 3-6" SOLID BARRIER AND FENCE

    FOR SNOW REMOVAL AREAS

    3-

    6"

    MI

    N.

    3-

    6"

    MI

    N.

    FENCE OR ORNAMENTAL RAILING

    8

    MI

    N.

    10

    MI

    N.

    PEDESTRIAN WALKWAY

    FENCE

    BARRIER

    FENCE OR ORNAMENTAL RAILING

    VIADUCT CROSS SECTIONNO SNOW REMOVAL AREAS

    BARRIER

    PERPENDICULAR TO TRACKS

    * FENCES, SPLASHBOARDS, OR SOLID BARRIERS IF REQUIRED SHALL EXTEND 25FT.BEYOND CENTERLINE OF OUTER MOST TRACK OR ACCESS ROADWAY.

    18 MIN.20 MIN.25 MIN.

    TOPOF

    RAIL

    BASEOF

    RAIL15 MIN.

    6

    2

    3-

    8"STANDARD

    "V"DITCH6

    MI

    N.

    TOP OFSUBGRADE

    ACCESSROAD

    STANDARDFLAT

    BOTTOMDITCH

    610

    MIN.

    SLOPE PAVING

    SLOPE PAVING

    FENCE

    CL CL CLACCESSROAD

    FUTURETRACK

    EXISTINGTRACK

    BARRIER ANDSPLASHBOARD

    25 MIN.*

    25 MIN.*

    ELEVATION

    GENERALFENCE SHALL BE PROVIDED AS INDICATED ON THE CROSSSECTIONS AND ELEVATION VIEW ON BOTH SIDES OF THEVIADUCT IN ALL NEW OR MODIFIED STRUCTURES.

    SPLASHBOARDS OR SOLID 3-6" HIGH BARRIER RAILSHALL BE PROVIDED AS INDICATED ON THE CROSSSECTIONS AND ELEVATION VIEW ON BOTH SIDES OF THEVIADUCT IN ALL NEW OR MODIFIED STRUCTURES WHERESNOW REMOVAL IS BEING PERFORMED.

    LIGHTS ARE TO BE INSTALLED ON THE UNDERSIDE OFTHE VIADUCT WHERE SHADOWS CAST BY THE STRUCTUREWOULD INTERFERE WITH RAILROAD OPERATIONS.

    SLOPE PAVING SHALL BE PROVIDED WHERE END SLOPESEQUAL TO, OR EXCEED, 2 HORIZONTAL TO 1 VERTICAL.

    FALSEWORK FOR CONSTRUCTION OF OVERHEAD STRUCTURESSHALL COMPLY TO AREMA GUIDELINES.

    DEMOLITION OF EXISTING OVERHEAD STRUCTURES SHALLCOMPLY TO KCSRC GUIDELINES.

    TEMPORARY SHORING SHALL BE DESIGNED IN ACCORDANCEWITH KCSRC SHORING REQUIREMENTS.

    APPLICANT SHALL BE RESPONSIBLE FOR IDENTIFICATIONLOCATION, AND PROTECTION OF EXISTING UTILITIES.

    CONTACT KCSRCS "CALL BEFOR YOU DIG" AT LEAST 48HOURS PRIOR TO COMMENCING WORK TO DETERMINE LOCATIONOF FIBER OPTICS.

    EXCEPTIONS TO THESE STANDARDS MUST BE APPROVED BYKCSRCS CHIEF ENGINEER DESIGN.

    CLEARANCESMINIMUM VERTICAL CLEARANCE SHALL BE 23-6" ABOVETHE PLANE OF TOP-OF-RAILS. ADDITIONAL CLEARANCEMAY BE REQUIRED FOR CONSTRUCTION PURPOSES OR IFSAG OF VERTICAL CURVE MUST BE ADJUSTED, OR IFFUTURE TRACK RAISE FOR FLOOD CONSIDERATIONS ORMAINTENANCE IS PROBABLE.

    MINIMUM HORIZONTAL CLEARANCES, MEASURED AT RIGHTANGLE FROM CENTERLINE OF TRACK, SHALL BE AS SHOWNIN ELEVATION VIEW.

    MINIMUM CONSTRUCTION CLEARANCES SHALL BE 21 FEETVERTICAL ABOVE THE PLANE OF TOP-OF-RAILS AND 12FEET HORIZONTAL AT RIGHT ANGLE FROM CENTERLINE OFTRACK.

    FUTURE TRACKSSPACE IS TO BE PROVIDED FOR ONE OR MORE FUTURETRACKS AS REQUIRED FOR LONG RANGE PLANNING OR OTHEROPERATING REQUIREMENTS. WHERE PROVISION IS MADE FORMORE THAN TWO TRACKS, SPACE IS TO BE PROVIDED FORACCESS ROAD ON BOTH SIDES OF TRACK.

    PIERSPIER PROTECTION WALLS SHALL BE PROVIDED INACCORDANCE WITH AREMA, CHAPTER 8, PART 2.1.5FOR PIERS WITHIN 25 FEET OF THE CENTERLINE OF TRACK.

    TOP OF FOOTINGS WITHIN 25 FT. FROM CENTERLINE OFTRACK SHALL BE A MINIMUM OF 6 FEET BELOW BASE OFRAIL AND A MINIMUM OF 1 FOOT BELOW FLOW LINE OFDITCH.

    DRAINAGEDRAINAGE FROM THE OVERPASS SHALL BE DIVERTED AWAYFROM KCSRCS TRACKS AND NOT DISCHARGED ONTO THETRACKS OF ROADBED.

    A STANDARD "V" SHAPED OR FLAT-BOTTOM DITCH SHALLBE PROVIDED ON EACH SIDE OF THE TRACKS AS NECESSARY.CULVERTS MAY BE INSTALLED ON OPPOSITE SIDE OFCOLUMN FROM TRACK IN LIEU OF STANDARD RAILROADDITCHES WHEN APPROVED BY CHIEF ENGINEER DESIGN.MAINTENANCE OF CULVERTS IS TO BE AT APPLICANTSEXPENSE.

    23-

    6"

    MI

    N.

    1-27-05

    NONE

    RGT

    4-27-07BARRIERS AND CLEARANCES TO BE

    PROVIDED AT HIGHWAY, STREET ANDPEDESTRAIN OVERPASSES BR-120

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • BARRIER

    BARRIER WITH FENCENO SCALE

    PIPE POST

    CHAIN LINKFENCE

    3-

    6"

    MI

    N.

    10-

    0"

    FENCE FOR WALKWAYSNO SCALE

    BARRIER

    NO SCALE

    10-

    0"

    BARRIER

    NO SCALE

    5-

    0"

    MI

    N.

    BARRIER WITH SPLASHBOARD

    SPLASHBOARD

    5-

    0"

    MI

    N.

    SPLASHBOARD

    CHAIN LINKFENCE

    TOP RAIL

    BOTTOM RAIL

    LINE POST

    BARRIER WITH SPLASHBOARDAND FENCE

    3-

    2

    "

    8-

    0"

    3-2"

    CHAIN LINKFENCE

    PIPE POST

    HANDRAIL

    R =

    3-0"

    1-27-05

    NONE

    RGT

    4-27-07BARRIERS, FENCES AND SPLASHBOARDSTO BE PROVIDED AT HIGHWAY, STREET

    AND PEDESTRAIN OVERPASSES BR-121

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • SAMPLEEXCAVATION

    ZO

    NE

    B

    SH

    ORIN

    G

    ZO

    NE

    B

    SH

    ORIN

    G

    3650mm (12-0")MAIN LINE ANDBRANCH TRACK

    INDUSTRY TRACK

    3810mm (12-6") (BRANCH LINE TRACK)3500mm (11-6") OR TO EDGE OF EXIST.

    SUBGRADE (INDUSTRY TRACK)

    ZO

    NE

    C

    SH

    ORIN

    G

    ZO

    NE

    C

    ONLY VERTICAL SHORING WILL BE PERMITTED FOR EXCAVATION IN

    THIS ZONE, (NO SLOPING

    CUTS.)

    GROUND LINE

    C

    OF

    TR

    AC

    KL

    TIE LENGTH

    q = 80,000 lbs

    (5 FEET)(8.5 FEET)

    PRESSURE DISTRIBUTION FOR STRIP LOAD

    (AREMA FIGURE 8.20-2)

    TIE LENGTH =

    8-6"

    s

    hs

    h

    SHORING PER OSHA

    21

    BASE OF RAIL

    (7-9")

    1.5

    1

    ZONE A SHORING

    q(psf)

    450mm

    (135

    -0")

    2360mm

    q(psf)

    4570mm (15-0") (MAIN LINE TRACK)

    80,000 lbs

    (5 FEET)(8.5 FEET)80,000 lbs

    (5 FEET)(8.5 FEET)

    SAMPLEEXCAVATION

    ZO

    NE

    B

    SH

    ORIN

    G

    ZO

    NE

    B

    SH

    ORIN

    G

    3650mm (12-0")MAIN LINE ANDBRANCH TRACK

    INDUSTRY TRACK

    3810mm (12-6") (BRANCH LINE TRACK)3500mm (11-6") OR TO EDGE OF EXIST.

    SUBGRADE (INDUSTRY TRACK)

    ZO

    NE

    C

    SH

    ORIN

    G

    ZONE B

    ZO

    NE

    C

    ALL SHORING TO COMPLYWITH OSHA REQUIREMENTS

    SHORING MUST BEDESIGNED FOR RAILROADLIVE LOAD SURCHARGEIN ADDITION TO OSHASTANDARDS FOR EXCAVATION.APPLICABLE RAILROADLIVE LOAD;COOPER E80

    GROUND LINE

    C

    OF

    TR

    AC

    KL

    TIE LENGTH

    q = 80,000 lbs

    (5 FEET)(8.5 FEET)

    PRESSURE DISTRIBUTION FOR STRIP LOAD

    (AREMA FIGURE 8.20-2)

    TIE LENGTH =

    8-6"

    s

    hs

    h

    SHORING PER OSHA

    21

    BASE OF RAIL

    (7-9")

    1.5

    1

    ZONE A SHORING

    q(psf)

    450mm

    (135

    -0")

    2360mm

    q(psf)

    4570mm (15-0") (MAIN LINE TRACK)

    80,000 lbs

    (5 FEET)(8.5 FEET)80,000 lbs

    (5 FEET)(8.5 FEET)

    TRACK PROTECTION SHORING:

    ALL DIMENSIONS ARE MEASURED PERPENDICULAR TO C OF TRACK.

    PRIOR TO COMMENCING ANY WORK, THE CONTRACTOR SHALL SUBMIT

    FOR APPROVAL BY THE RAILROAD ENGINEER, DETAILED PLANS INDICATING

    THE NATURE AND EXTENT OF THE TRACK PROTECTION SHORING PROPOSED.

    THE CONTRACTOR SHALL PROVIDE AND INSTALL TRACK PROTECTION SHORING

    BEFORE COMMENCING EXCAVATION.

    SHORING WITHIN ZONE A SHALL BE DESIGNED FOR COOPER E80 LIVE

    LOAD SURCHARGE, IN ADDITION TO ALL OTHER APPLICABLE LOADS. THE

    RAILROAD MAY IMPOSE MORE STRINGENT REQUIREMENTS AS CONDITIONSWARRANT.

    FOR EXCAVATIONS WHICH ENCROACH INTO RAILROAD LIVE LOAD SURCHARGE

    ZONE A, SHORING PLANS WILL BE ACCOMPANIED BY A COPY OF DESIGN

    CALCULATIONS, AND BOTH MUST BE STAMPED BY A REGISTERED PROFESSIONAL

    ENGINEER IN THE APPLICABLE STATE.

    THE PRESSURE AT A GIVEN POINT OF A CONTINUOUS STRIP OF SURCHARGE LOAD

    q(psf) PARALLEL TO SHORING SHALL BE COMPUTED IN ACCORDANCE WITH AREMASECTION 8.20.3.

    L

    NO EXCAVATION

    2150mm (7-0")

    EXCAVATION PERMITTED

    a

    b

    b

    /2

    NO EXCAVATION

    2150mm (7-0")

    EXCAVATION PERMITTED

    ZONE A

    a

    b

    b

    /2

    1-27-05

    NONE

    RGT

    4-27-07GENERAL SHORING REQUIREMENTS

    BR-122

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 20-0" 10-0"

    50-0"

    LIMIT OFPROTECTEDSTRUCTURE

    LIMIT OFPROTECTEDSTRUCTURE

    11"FLANGEWAY

    P.

    C.

    GENERAL ARRANGEMENT

    CUT RAIL BASE AT POINT END OF GUARD

    2-2"

    1"

    2ND HAND INSULATED JOINT

    HOOK TWIN PLATES

    1"

    5"

    12"

    TOP OF TIE

    DEPRESSED RAIL HEAD DETAIL

    INSTALLATION

    CUT AWAY WEBAND BASE AND BEND

    HEAD DOWN BELOWTOP OF TIE.

    NOTES:

    BE OF THE SAME RAIL SECTION AS THERUNNING RAILS BUT MUST NOT BE MORETHAN 23 LBS. LIGHTER THAN THERUNNING RAILS.

    70 LBS. SHALL BE USED.

    TIE PLATED WITH SECOND HAND TIEPLATES, WHERE CLEARANCES PREVENTSTHE USE OF TIE PLATES, HOOK TWINPLATES CAN BE USED IN GUARD RAILCONVERGENCE AREA.

    RUNNING RAIL PLATES AND THE GUARDRAIL PLATES MUST NOT BE LESS THAN 1".

    CANT THE GUARD RAIL OUTWARD TOWARDTHE RUNNING RAIL. WHEN SINGLE SHOULDERFLAT GUARD RAIL PLATES ARE USED,INSTALL THE PLATES WITH THE SHOULDERSON THE INSIDE TOWARD THE CENTER OF THETRACK.

    THEIR FULL LENGTH WITH 2 SPIKES PERTIE. WHERE NECESSARY, PARTICULARLY ONCURVES, DOUBLE SPIKE GUARD RAIL BOTHINSIDE AND OUT.

    BOLTED AND WHEN AVAILABLE, SECOND HANDJOINTS SHOULD BE USED.

    REFERS TO POSTS, COLUMNS, BENTS,PIERS, ABUTMENTS, ETC. SUPPORTINGBRIDGES, VIADUCTS, ETC. OVER ORADJACENT TO THE TRACK.

    GRADE SEPARATION STRUCTURES:DOUBLE INSIDE GUARD RAILS ARE TO BEINSTALLED ON ALL F.R.A. CLASS 4 AND 5TRACK WHERE HORIZONTAL CLEARANCES ONBOTH SIDES ARE LESS THAN 18 FEET FROMTHE CENTERLINE OF TRACK TO A SUPPORTINGMEMBER. CLASS 2 CARRYING MORE THAN 20M.G.T. TRAFFIC AND ALL CLASS 3 TRACK SHALLHAVE DOUBLE INSIDE GUARD RAILS INSTALLEDWHERE HORIZONTAL CLEARANCE ON BOTH SIDESIS LESS THAN 12-6" FROM THE CENTERLINE OFTRACK TO A STRUCTURE SUPPORTING MEMBER.

    BRIDGES LOCATED ON CLASS 3, 4, AND 5 TRACK,ALONG WITH BRIDGES LOCATED ON CLASS 2 TRACKWITH OVER 20 M.G.T.

    DOUBLE INSIDE GUARD RAILS ARE TO BE INSTALLEDON:ALL THROUGH OR DECK TRUSSES AND THROUGH PLATEGIRDER SPANS.ALL BRIDGES THAT ARE 40 FEET OR HIGHER AND150 FEET IN LENGTH, AND ON ALL BRIDGES 30 FEETOR MORE IN LENGTH WHERE CURVATURE EXCEEDS 5DEGREES; UNLESS EXCEPTION IS APPROVED BY CHIEFENGINEER.

    15-0"INSULATED JOINT

    10-0" 10-0"

    18"FLANGWAY

    14"FLANGWAY

    11"FLANGWAY

    1-27-05

    NONE

    RGT

    4-27-07DOUBLE INSIDE GUARDRAIL

    BR-123

    NOTE 1: *

    1. S/H BOLTED RAIL FROG POINTS AREPREFERRED TO USE IN THIS INSTALLATION

    FROM SECOND HAND RAIL AND MAY

    IF AVAILABLE.

    2. INSIDE GUARD RAILS SHALL BE MADE

    3. NO INSIDE GUARD RAIL LIGHTER THAN

    4. INSIDE GUARD RAILS ARE TO BE FULLY

    5. MINIMUM CLEARANCE BETWEEN THE

    6. INSTALL GUARD RAIL PLATES SO AS TO

    7. INSIDE GUARD RAILS TO BE SPIKED TO

    8. ALL GUARD RAIL JOINTS TO BE FULLY

    10. GRADE SEPARATION SUPPORTING MEMBER

    9. GUARD RAIL TO BE LAID WITH FULLRAIL (NO JOINTS) IN THE CURVEDPOSITION.

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    NOTES:1) USE 6 PILE BENT WHERE H EXCEEDS 37 FEET. 2) ALL TIMBER & PILES TO BE CREOSOTED. 12# TIES, 16#/in2 PILES.

    4) HEIGHT, H, IS DISTANCE BASE OF RAIL TO GROUND.5) TOPS OF PILES SHALL NOT BE CHAMFERED.6) AFTER CUT-OFF, TOP OF PILE SHALL BE PROTECTED WITH PILE PADS.7) TOWER BRACING TO BE PREFERABLY PLACED ON PILES 1 & 5.

    4X10X19

    6X6X16

    4X10X19

    6X6X16

    I-PL 3 1/2" X 1/2" X 2-6"CAP STRAP CS 1

    6X8X30

    BRACING IN BOTTOM PANEL

    17

    18

    18

    19

    20

    19

    19

    20

    21

    22

    22

    24

    23

    X BRACESCBAH

    9-0"4-6"27

    4-10"

    5-0"4-11"

    3332

    31

    4-7"

    4-8"

    4-9"30

    29

    28

    9-8"

    10-0"9-10"

    9-2"

    9-4"

    9-6"

    4-2"23

    4-4"

    4-5"

    4-3"

    26

    25

    24

    4-0"

    4-1"22

    21

    8-4"

    8-8"

    8-10"

    8-6"

    8-0"

    8-2"

    AT GROUND LINE

    SASH

    21

    22

    2322

    21

    21

    22

    OMIT

    OMIT

    19

    20

    20

    20

    WHERE BRACING IS OMITTED USE CUP STRAP CS1 FASTEN CAPS TO PILES1 & 5.

    20" BOLTS

    EVERTIGHT WASHER

    NUT

    EVERTHIGHT WASHER

    34 10-2"5-1"

    35 10-4"5-2"

    36 10-6"5-3"

    37 10-8"5-4"

    SPACING OF PILES

    4-9"

    5-4"

    5-2"

    5-3"

    5-1"

    4-11"

    5-0"

    4-10"

    4-3"

    4-6"

    4-8"

    4-7"

    4-4"

    4-5"

    4-1"

    4-2"

    4-0"

    25

    26

    26

    27

    OMIT

    OMIT

    19

    19

    HEIGHTS 21 FT TO 37 FT INCLUSIVE

    SPACING OF PILES AT GROUND LINE

    13 3-4"

    20 3-11"

    18

    19

    17

    3-9"

    3-10"

    3-8"

    1516

    14

    3-6"3-7"

    3-5"

    7 2-10"

    10 3-1"

    12

    11

    3-3"

    3-2"

    8

    9

    2-11"

    3-0"

    5

    6

    4

    2-8"

    2-9"

    2-7"

    HA

    186-8"

    237-10"

    7-6"

    7-8"

    7-4"

    22

    23

    21

    7-0"7-2"

    6-10"1920

    18

    OMIT5-8"

    166-2"

    6-6"

    6-4"

    17

    16

    5-10"

    6-0"

    15

    15

    5-4"

    5-6"

    5-2"

    OMIT

    OMIT

    OMIT

    B C X BRACES

    HEIGHTS 20 FT OR LESS

    3-4"

    3-11"

    3-9"

    3-10"

    3-8"

    3-6"3-7"

    3-5"

    2-10"

    3-1"

    3-3"

    3-2"

    2-11"

    3-0"

    2-8"

    2-9"

    2-7"

    HEIGHTS 21 TO 37 INCLUSIVE

    HEIGHTS 20 OR LESS

    B A B

    TYPICAL BOLT ASSEMBLY

    A

    BASE OF RAIL

    4X10X19

    4X8X19

    6X8X30

    2-4x10

    P/S CONC. CAP TIMBER CAP2-6"2-6" 2-6"2-6"2-6"2-6"2-6" 2-6"

    (14X15X14 P/S CONC. CAP)(14X14X14 TIMBER CAP- OPTIONAL)

    4x10

    4x10x10-6"

    4x10x20

    3x10

    16" bolts

    18" BOLTS

    A2

    22" BOLTS

    24" BOLTS

    19" BOLTS

    19" BOLTS

    PILE CUT OFF

    A2

    BOLT THROUGH

    BOLT THROUGH34"x19" BOLT W/WASHER & SPRING

    (ADD) EVERTIGHT SPRING

    6x6x16

    1 3/4"

    2"

    26"

    3-1/2"

    CC

    B BAA

    CC

    H= 37 MAX.

    H=21 MIN.

    13-0"

    14-0" 14-0" 14-0"

    1-11 1/2" 3-1 1/2" 3-1 1/4"

    H=20 MAX.

    1-27-05

    NONE

    RGT

    4-27-07 STANDARD PILE TRESTLE5 PILE BENTS & BRACING BR-124

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    NUT

    EVERTIGHT WASHER

    EVERTIGHT WASHER

    NOTES:1) USE 5 PILE BENT WHERE H= 37 FEET OR LESS. CONSULT WITH BRIDGE ENGINEER FOR DETAILS OF BENTS EXCEEDIND 50 IN HEIGHT.2) ALL TIMBER & PILES TO BE CREOSOTEDS. 12#/in 2 TIES 16# /in 2 PILES

    4) HEIGHT, H, IS DISTANCE BASE OF RAIL TO GROUND.5) TOPS OFPILES SHALL NOT BE CHAMFERED.6) AFTER CUT-OFF, TOP OF PILE SHALL BE PROTECTED WITH PILE PADS.7) TOWER BRACING TO BE PREFERABLY PLACED ON PILS2 & 5 OR 1 & 6.

    CAP STRAP CS 1I-PL 3 1/2" X 1/2" X 2-6"

    BDDB

    HEIGHTS 38 TO 50 INCLUSIVE

    20" BOLTS

    22" BOLTS

    3-1 1/4"

    PILE CUT OFF

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    4950

    HA

    5-10"5-10"

    5-8"

    5-8"

    5-6"

    5-6"

    5-2"

    5-4"

    5-4"

    5-2"

    5-0"

    5-0"

    4-10"

    B

    3-11"4-0"

    3-11"

    3-10"

    3-10"

    3-9"

    3-7"

    3-8"

    3-9"

    3-8"

    3-7"

    3-6"

    3-6"

    C

    5-10"5-11"

    5-9"

    5-8"

    5-7"

    5-6"

    5-2"

    5-4"

    5-5"

    5-3"

    5-1"

    5-0"

    4-11"

    D

    2-11"

    2-11"

    2-10"

    2-10"

    2-9"

    2-9"

    2-7"

    2-8"

    2-8"

    2-7"

    2-6"

    2-6"

    2-5"

    E

    6-10"6-11"

    6-9"

    6-8"

    6-7"

    6-6"

    6-2"

    6-4"

    6-5"

    6-3"

    6-1"

    6-0"

    5-11"

    F

    12-8"12-10"

    12-6"

    12-4"

    12-2"

    12-0"

    11-4"

    11-8"

    11-10"

    11-6"

    11-2"

    11-0"

    10-10"

    X BRACES

    3030

    29

    28

    28

    27

    24

    26

    26

    25

    24

    24

    23

    SASH

    27

    27

    26

    26

    26

    26

    24

    25

    25

    24

    24

    OMIT

    OMIT

    BOTTOM PANELBRACING IN SPACING OF PILES

    BASE OF RAIL

    4X10-19

    6X6-16

    4X10-19

    6X6X16

    6X6X16

    4X10-19

    4X10-19

    4X10-19

    2-4X10

    4X10

    2-4X10-20

    4X10-22

    2-4X10-16

    4X10-20

    22" BOLTS

    P/S CONC. CAP TIMBER CAP

    22" BOLTS

    (14X14X14 TIMBER CAP- OPTIONAL)

    (14X15X14 P/S CONC. CAP)(AREMA TYPE, KCS STANDARD)

    20" BOLTS

    22" BOLTS

    222 2 2

    TYPICAL BOLT ASSEMBLY

    AT GROUND LINE

    4x10

    SPRING

    6X6-16

    26"

    2"

    3 1/2"1 3/4"

    14-0"14-0" 14-0"

    C

    A

    C

    E E

    F F

    13-0"

    13-0"

    1-11 1/2"3-1 1/2"

    H-38 MIN.

    H-50 MAX.

    1-27-05

    NONE

    RGT

    4-27-07 STANDARD PILE TRESTLE6 PILE BENTS & BRACING BR-125

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    TYPE ITYPE II

    TYPE IIIUSE 6 PILE BENTS WHERE "S" = 11-0" OR 12-0"USE 5 PILE BENTS ON ALL OTHERSELEVATION OF BRIDGES

    TYPE I TYPE II

    TYPE III

    DETAILS OF RAIL GIRDERS

    7 PLY RAIL GIRDER

    5 PLY RAIL GIRDER

    PLATES P1 & P2

    HALF SECTIONBETWEEN SUPPORTS

    HALF SECTIONAT SUPPORTS

    HALF SECTIONBETWEEN SUPPORTS

    HALF SECTIONAT SUPPORTS

    FRAMING DETAIL- CAP C4

    FRAMING DETAIL- CAP C5

    RODS R1, R2 & R3

    HALF SECTIONBETWEEN SUPPORTS

    HALF SECTIONAT SUPPORTS

    SECTIONS THRU BRIDGE- 7 PLY GIRDERS

    ANCHOR ANGLE A2

    FRAMING DETAIL- TIES T3 TO T8ANCHOR ANGLE A5

    SIMILAR FOR 5 PLY GIRDERS

    WASHER W1

    WASHER W2

    DETAILS OF BENTS

    HALF ELEVATION -6 PILE BENT 5 PILE BENT

    14X14X14 CAP- SIZED TO 13 3/4" X 13 3/4"

    I - L5X3X3/8X 4"

    HALF ELEVATION

    4 EA. 3/4 X 11" LAG SCREWS WITH WASHER W2

    5/16"

    1/4"

    2"13/16"

    2"15/16"

    14X14S4S TO 13 3/4" X13 3/4"

    C4C5

    A2 A2

    8"

    3/4"

    X 18" BOLTS

    3/4" X 16" BOLTS1-0"

    2-6"2-6"2-0"2-0"

    3"

    1 3/4"

    5"

    3 1/4"

    2"

    9 5/8"

    8 7/8"

    5 7/8"

    9 5/8"

    8 7/8"

    5 7/8"

    T7 & T8

    T5 & T6

    T3 & T4

    7/8" HOLES IN TIES T3, T5 & T7 ONLY

    10-0"

    2- 2"2-10"2- 2"T7 = 1-5"

    2- 1/2"2-11 1/2"2-1/2"T5 = 1-5 3/4"

    1-6 1/2"3-5 1/2"1-6 1/2"T3 = 1-8 3/4"

    5-02-6"

    "D"

    5-0" C/C GIRDERS

    2-6"2-6"

    4 1/2" X8" GD. TBR.SIZED TO 4" X 7 3/4"3/4" X 10" MACH. BOLTS

    WITH 1 MAN. WASHER

    SECURITY LOCK NUTS

    SECURITY

    ANGLE A5

    ANGLE A5

    ANGLE

    8"X8"X10 TIESIZED TO

    7 3/4" X 7 3/4"SPACED 1 CENTERS

    13/16" X 2" SLOT

    HOLE

    4"

    1 3/4"

    3"13/16" HOLES

    2"11"2"

    7 3/4"

    7/8" HOLES IN TIES T3, T5 & T7 ONLY

    7 3/4"7 1/4"

    2 HEX. NUTS

    R3 = 19"

    R2 = 25"R1 = 27"

    7/8" 4"THREAD3"

    4-0"4-0"

    3/4" STAGGERED LAG SCREW WITH MALL

    WASHER IN ALL TIES

    TOP OF CAP

    13 3/4"

    14-0"

    2-0"2-0"2-0"1-0" 1-0"

    2-0"

    13/16" HOLES

    13/16" HOLES TOP OF CAP

    8"

    14-0"

    2-6"2-6"2-6"2-6"

    13 3/4"

    1/2"

    "C"

    1-1"

    1" HOLE IN RAILS

    PLATE P2

    HEX. NUT

    ROD R3WASHER W1

    "C"

    1-4"1/2"

    1" HOLE IN RAILS

    PLATE P1

    HEX. NUT

    ROD R1 OR R2WASHER W1

    NOTE:RAILS SHOWN DOTTED TO BE SHIPPED INDEPENDENTLY AND ASSEMBLED IN FIELD

    "A"

    3 3/4"

    "B"

    3"

    P2 = 1-11"

    1 1/2" P1 =2-5" 1 1/2"

    6"

    3"

    "L"

    "L""L"

    7"1/2 "S"1/2 "S"7"

    1 1/8"

    HOLES

    7" 1/2 "S" 1/2 "S" 1/2 "S" 1/2 "S" 1/2 "S" 1/2 "S" 7"

    7/8"

    RODS

    7" 1/2 "S" 1/2 "S" 1/2 "S" 1/2 "S" 7"

    7/8"

    RODS7/8"

    RODS

    6"6"

    6"6"

    6"6"

    6"6"

    6"6"

    6"6"

    6"6"

    6"6"

    P1 OR P2P1 OR P2 P1 OR P2 P1 OR P2

    P1 OR P2P1 OR P2P1 OR P2P1 OR P2

    6"6"

    BASE OFRAIL

    BASE OFRAIL

    CONCRETE BACK WALLSCONCRETE BACK WALLS

    GROUNDGROUNDGROUND

    "L"

    7""S""S""S"7"

    "L"

    7""S""S"7"7""S"7"

    "L"

    A5

    LOCK NUTS

    OR BOLT THROUGH CONC. CAP

    1-27-05

    NONE

    RGT

    4-27-07 STANDARD RAIL GIRDERSON PILE BENTS BR-126

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    ELEVATIONLC

    1 1/2:

    1

    NO SCALE

    5 OR 6 PILE BENTS

    BACKWALL

    5 PILE BENT

    DRIVE SCREWS EVERY TIE DRIVE SCREWS IN EVERY OTHER TIE

    A1

    8X16X14-0"8X16X28-0"

    8X16X28-0"

    PLAN

    NOTES:1) ALL TIMBER SHALL BE CRESOTED. (#16)2) CREOSOTED TIMBERS SHALL BE HANDLED CAREFULLY TO AVOID DAMAGE TO SURFACE FIBERS. WHERE TIMBERS HAVE BEEN BRUISED OR SPLINTERED IN HANDLING, THE DAMAGE PORTION SHALL BE GIVEN A COAT OF HOT PRESERVATIVE. WHERE TIMBERS HAVE BEEN IMPROPERLY BORED, OR SPIKES REMOVED, HOLES SHALL BE PLUGGED AND SEALED WITH HOT PRESERVATIVE.3) FIELD BOLT HOLES AND CUTS TO BE TREATED WITH HOT PRESERVATIVE.

    A1

    HARDWARETIMBER

    STRINGERS

    1

    2

    3

    4

    1

    8

    0

    8

    8

    0

    0

    8

    8

    12

    4

    14

    28

    42

    56

    14

    2

    4

    6

    8

    2

    30

    58

    86

    114

    28

    8

    16

    24

    32

    8

    8

    16

    24

    32

    8

    8

    12

    16

    20

    4

    16

    32

    48

    64

    16

    4

    6

    8

    10

    2

    176

    304

    431

    559

    1:29

    8 X 16

    SIE TO 15 3/4"

    LENGTH

    14-0" 28-0"

    TOTAL WEIGHT

    LBS.

    AMOUNT TO ADD FOR EACH ADDITIONAL PANEL

    5 X 8 GUARD TIMBER

    TIES 7 X 8 X 10

    DRIVE SCREWS 3/4" X 11"WITH WASHER HEAD & SQ. HD.

    BOLTS

    1 SPRING. WASHER

    SECTION A-A

    ANCHOR ANGLE A1

    1 L3 1/2X3 1/2X3/8X2-2 1/2"

    A

    A

    1 MALL. WASHER1-SPRING

    A1 A1

    CL

    DRIVE SCREWS3/4" X 11"

    BRIDGE

    PILE CUT OFF

    14X15X14 ( KCS STANDARD) P/S CONC. CAP

    TIE

    S - 8

    X8

    X10

    SISIE

    TO 7

    3/

    4X 7 3/

    4

    GD.T

    BR.

    4X8

    X14

    SISIE

    TO 3

    3/

    4"

    X 7 3/

    4"

    S

    Q.

    HD.

    DRIV

    E

    SC

    RE

    WS

    5/

    8"

    X 9"

    SQ.

    HD

    DRIV

    E

    SC

    RE

    WS

    3/

    4"

    X 11"

    W/

    HE

    AV

    Y

    NU

    TS

    W/

    HE

    AV

    Y

    SQ.

    NU

    TS

    BO

    LTS

    AN

    CH

    OR

    LS

    A1

    TIMBER

    CAP

    TIMBER

    CAP

    CONC. CAP

    TIMBER

    CAP

    CONC. CAP

    CONC. CAP

    (14X14X14 TIMBER CAP OPTIONAL)

    NO.

    OF

    PA

    NE

    LS

    MATERIAL FOR DECK

    CL CL

    1-2"

    2 1/4"

    SP

    RIN

    GS

    FO

    R

    3/

    4"

    BO

    LTS

    16

    32

    48

    64

    16

    6"13 @ 1-0" = 13-0"

    7 3/4"

    9"9"

    4"

    13@ 1-0" = 13-0"6" TIE SPACING

    9"

    INTERMEDIATE PANEL 14-0" END PANEL 13-5"

    1-9"4-0"

    3 1/4"

    2"

    2"

    6 3/4"

    7 3/4"

    7 1/2"

    1 3/4"

    2-8"

    1-2"

    2-8"

    3 1/2"

    6 3/4"

    7 3/4"

    1-3 3/4"

    1-1 3/4"

    1-11 1/2" 2-0 3/4"

    1-3"

    3-1 1/4" 3-2 3/4"

    5-0" 5-0"

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    ITE

    M

    No.

    -

    1-27-05

    NONE

    RGT

    4-27-07 DECK FOR CREOSOTED PILE & FRAMETRESTLE, 14 PANELS BR-127

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    12-

    0"

    BA

    TT

    ER

    1 IN

    12

    NO SCALE

    SECTION

    4-81/2"

    CL

    TIES 8"X8"X10-0"

    14"

    2-3"1-9"

    4-21/2"

    3-71/2"

    2-3" 1-9"

    BA

    TT

    ER

    2

    IN

    12PLAN

    8"X16"X28-0"

    STRINGERS

    3/4"X11" DRIVE SCREW

    3/4"X36" BOLTS

    3/4"X22" BOLTS

    34" x 11" SQ. HD.DRIVE SCREWS

    5"X8 GUARD RAIL

    5"X8" GUARD RAIL

    3/4"X36" BOLT

    14"X14"X14-0" CAP

    4"X10" SWAY BRACESB

    AT

    TE

    R

    2

    IN

    12

    BA

    TT

    ER

    1 IN

    12

    4"X10" SASH BRACE

    3/4" BOLTS

    7"x8"X14 WALKWAY TIE

    8X10 LONGITUDE BRACE

    34"x19" DRIFT PIN

    8X10 LONGITUDE BRACE

    4"x4"x24" CAP ANCHOR ANGLE

    NOTES: 4" x 10" x 16-0" SWAY BRACE

    8" x 8" x 10-0" BRIDGE TIE

    ITEM NUMBERITEM DESCRIPTION

    5" x 8" x 20-0" GUARD RAIL

    QUANTITY

    -

    -

    -

    8" x 10" x 16-0" LONGITUDE BRACE

    14" x 14" x 14-0" CAP

    -

    -

    -

    -

    -

    -

    -

    -

    EA

    EA

    EA

    EA

    EA

    EA

    EA

    EA

    EA

    EA

    EA

    7" x 8" x 14-0" WALKWAY TIE

    " x 36" STRINGER BOLTS W/MALLEABLE IRON WASHERS AND NUTS

    " x 11" SQ HEAD DRIVE SCREWS

    " x 22" CAP BOLTS W/NUT AND 3" MALLEABLE IRON WASHERS

    4" x 4" x 24" CAP ANCHOR ANGLE

    8" x 16" x 28-0" STRINGERS

    1-27-05

    NONE

    RGT

    4-27-07 TIMBER PILE TRESTLETYPICAL COMPONENTS BR-128

    ALL STRINGER AND DECK BOLTS ARE EQUIPPED WITH EVER TIGHT WASHER ANDSPRING ASSEMBLIES, ALL SWAY BRACE AND GRIT BOLTS EQUIPPED WITH FLATWASHERS. SUPERELEVATION ON CURVES IS ATTAINED BY INCLINING EACH CAPTHE REQUIRED AMOUNT. TIES AND TIE SPACERS ARE TO BE TREATED WITHARBAN FIRE RETARDANT.

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    YEAR AND MONTH THE RAIL

    WAS ROLLED. THE FOUR LINES

    INDICATE APRIL, THE 4TH MONTH.

    MANUFACTURER

    CONTROLLED COOLED

    RAIL SECTION

    WEIGHT OF RAIL PER YARD

    HEARTH NUMBER

    HEAT NUMBER

    INGOT NUMBER

    HEAD HARDENED

    END HARDENED

    133

    RE

    CC

    CF81

    1975 IIII

    CH

    2

    0816

    A12

    HH

    RAIL BRANDING AND STAMPING IDENTIFIES RAIL USING A UNIQUE IDENTIFICATION SYSTEM. RAIL MANUFACTURERS FORM THE MARKINGS INTO THE RAIL DURING THE MANUFACTURING PROCESS. CHECK RAIL BRANDING AND STAMPING TO DETERMINE THE TYPE OF RAIL BEFORE WELDING.BRANDING APPEARS AS RAISED LETTERING ON THE RAIL WEB AND IDENTIFIES THE RAIL WEIGHT AND SECTION, MANUFACTURER NAME, AND THE YEAR AND MONTH ROLLED.RAIL STAMPINGS ARE IMPRINTED CHARACTERS ON THE WEB OPPOSITE THE BRANDING SIDE.

    3-6-02

    NONE

    DLL

    4-27-07RAIL IDENTIFICATION

    RA-101

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    NOTES:

    1) BEVEL RAIL END AT 116" X 18" ACROSS TOP OF HEAD AND TAPER THE BEVEL ALONG THE SIDE OF HEAD AS ILLUSTRATED.

    2) CHAMFER BOLT HOLES ON BOTH SIDES IN ORDER TO ELIMINATE SHARP EDGES AND TO PRODUCE 18" CURVED SURFACES AS ILLUSTRATED.

    SIDE ELEVATION

    SECTION SHOWING RAIL END BEVEL SECTION SHOWING

    BOLT HOLE CHAMFER

    END ELEVATION

    CHAMFER DETAIL

    18" R

    116"

    18"

    4-21-06

    NONE

    DLL

    4-27-07BEVELING & CHAMFERING

    RA-102

  • G2

    C

    E

    E1

    A

    H

    M

    K

    L

    K1

    > BOLT

    HOLESN

    P

    ST

    GAGE

    LINE

    "

    G1

    D> RADIUS

    > FISHING

    F

    T1

    S1S2

    R

    01O

    O2

    B1 B1

    B

    G

    U1

    U

    RAIL SECTION

    V W X

    M

    N

    WIDTH AT

    GAGE LINE

    DRILLING

    1-4-06

    NONE

    RGT

    4-27-07 RAIL SECTIONSSHEET No. 1 of 7 RA-103

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • BN 6 3 2 1 3 1 4 1 3 1 10 1 3 20 8 3 6 6136 27 1:4 1:4 1:40

    6 3 2 1fi 3 1 4 1 3 1 14 1 3 20 8 3 6 627 1:4 1:4 1:40136

    6 3 - - 3 1 4 1 3 1 14 1 3 20 8 3 6 627 1:4 1:4 1:40136RE

    6 3 2 1fi 3 1 4 1 3 1 14 1 3 20 8 3 6 627 1:4 1:4 1:40136RE

    6 3 2 1fl 3 1 4 1 3 1 10 1 3 16 8 3 6 637 1:4 1:4 1:40132RE

    CF&D

    6 3 2 1fl 3 1 4 1 3 1 10 1 3 16 8 3 6 637 1:4 1:4 1:40132RE

    6 3 2 1fl 3 1 4 1 3 1 10 1 3 16 8 3 6 637 1:4 1:4 1:40132RE

    6 3 2 1fl 3 1 4 1 3 1 10 1 3 16 8 3 6 637 1:4 1:4 1:40132RE

    6 3 2 1fl 3 1 4 1 3 1 10 1 3 16 8 2 6 637 1:4 1:4 1:40132RE

    6 3 2 1fl 4 1 4 - 1 3 1 14 1 3 - 23 10 6 -37 1:4 1:4 1:40132RE

    6 3 2 1fl 4 1 4 - 1 3 1 14 1 3 - 23 10 6 -37 1:4 1:4 1:40132RE

    6 3 2 1fl 4 1 4 - 1 3 14 1 3 - 23 10 6 637 1:4 1:4 1:40132RE

    6 3 2 1fl 4 1 4 - 1 3 1 14 1 3 - 23 10 6 -37 1:4 1:4 1:40132RE

    6 3 2 1fl 4 1 4 - 1 3 1 14 1 3 - 23 10 6 -37 1:4 1:4 1:40132RE

    1

    6 3 2 3 1 3 - 1 3 1 14 - 3 - 14 - 5 -26 1:4 1:4 1:16130RE 1 2

    2

    2

    2

    2

    2

    6 3 - 3 1 3 - 1 2 1 14 - 3 - 14 - 5 -26 1:4 1:4 1:16130RE - 2

    5 2 3 3 1 3 - 2 2 1 12 - 2 - 16 - 7 -36130 1 2PENNA 14 18 VERT

    6 3 2 3 1 4 - 1 3 1 14 - 3 1 - 14 - 6 627129 1 21:40TR 1:4 1:4

    5 2 2 3 1 3 1 2 1 14 1 3 14 3 6 626119 1 31:401:4 1:4CF&D

    5 2 - 3 1 3 - 1 2 1 14 1 3 - 14 3 6 626119 - 31:401:4 1:4RE

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 1 FOR RAIL SECTIONSSHEET No. 2 of 7 RA-104

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 3 6 6115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 3 6 6115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 3 6 6115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 3 6 6115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 2 2 2115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 2 6 -115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 1 2 1 10 1 3 3 14 3 3 6 6115 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 2 6 -112 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 2 6 6112 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 2 6 -112 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 3 6 6112 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 2 6 -112 1:4 1:4 1:40

    6HF 5 2 2 2 1 3 1 3 - 1 2 1 14 - - - - 23 10 2 6 -112 1:4 1:4

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 24 1 3 - 23 10 2 5 -112 1:4 1:4 1:40

    6RE 5 2 2 2 1 3 1 3 - 1 2 1 14 1 3 - 23 10 2 6 -112 1:4 1:4 1:40

    6TR 5 2 2 2fl 1 3 1 3 - 1 2 1 14 - 3 - 20 - 2 6 6112 1:4 1:4 1:40

    6TR 5 2 2 2fl 1 3 1 3 - 1 2 1 14 - 3 - 20 - 2 6 -112 1:4 1:4 1:40

    -

    6GN 5 2 2 2 1 3 1 3 - 1 3 1 14 - 3 - 14 - 2 7 -110 1:4 1:4 1:16

    6RE 5 2 2 2 1 3110

    6RE 5 2 2 2 1 3110

    6RE 5 2 2 2 1 3110

    6HF 5 2 2 2 - 3110

    6RE 5 2 2 2 1 3110

    6RE 5 2 2 - - 3110

    1 3 -1:4 1:4 1:16

    1 -1:4 1:4 1:16

    1 -1:4 1:4 1:16

    1 -1:4 1:4 55^

    1 -1:4 1:4 1:16

    1 -1:4 1:4 1:16

    3

    3

    3

    3

    3

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 14 -

    2 - 14 - 2 5 -

    2 - 14 - 3 6 6

    2 - 14 - 2 5 6

    - - 14 - 3 6 6

    2 - 14 - 2 5 6

    2 - 14 - 2 5 -

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 2 FOR RAIL SECTIONSSHEET No. 3 of 7 RA-105

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 5 2 2 2 1' 2 3^ 1 2 - 1 2 1 12 - 2 - 12 - 2 6 -100

    RE 100

    RE 100

    100

    GN 100

    ARA-B

    ARA-A

    5 13^ 13^

    6 2 2 2 1' 2 1 3 -5 1:4 1:4

    6 2 2 2 1' 2 -5

    6 2 2 2 1 2 3 -5

    5 2 2 2 1 2 1 3 -5

    1:16

    1:4 1:4 1:16 1 3

    1:4 1:4 1:16 1

    1:161:41:4

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 14 -

    1 2 1 12 -

    2 - 14 - 3 6 -

    2 - 14 - 2 5 -

    2 - 14 - 2 6 -

    2 - 14 - 2 7 -

    100

    100

    100

    100

    ASCE

    ARA

    REROLLED

    ASCE

    5 2 2 2 1 2 3 -5 13^ 13^

    6 2 2 2 1 2 1 3 -5 1:4 1:4

    5 2 - - - - - - - 3 -5

    5 2 2 2 1 2 3 -5 13^ 13^

    - -

    VERT

    1:16

    VERT

    1 2 1 12 -

    1 2 1 14 -

    - 2fl 1 - -

    1 2 1 12 -

    2 - 12 - 2 6 -

    2 - 14 - 2 5 -

    - - - - - - - - - - 2 6 -

    2 - 12 - 2 5 5

    5 2 2 2 1 2 3^ 1 2 - 1 2 1 12 - 2 - 12 - 2 6 -ARA-B 4 13^ 13^

    5 2 2 - - 2 - 2 - 1 2 1 12 - - - 12 - 3 6 -5 13^ 13^

    5 2 2 2 1 2 5^ 1 2 - 1 2 1 14 - 2 - 14 - 2 6 -5 13^ 13^

    5 2 2 - - 2 - 2 - 1 2 1 12 - - - 12 - 3 6 -5 13^ 13^

    5 2 2 2 1 2 1 3 - 1 2 1 14 - - - 14 - 3 6 -ARA-A 5 1:4 1:4

    5 2 2 2 1 2 1 3 - 1 2 1 14 - - - 14 - 2 6 -ARA-A 5 1:4 1:4

    5 2 2 2 1 2 5^ 1 2 - 1 2 1 14 - 2 - 14 - 2 6 -5 13^ 13^

    5 2 2 2 1 2 1 3 - 1 2 1 14 - - - 14 - 3 6 -ARA-A 5 1:4 1:4

    5 2 2 2 1 2 1 3 - 1 2fi 1 14 - 2 - 14 - 2 5 -ARA-A 5

    5 2 2 2 1 2 1 3 - 1 2 1 14 - - - 14 - 2 5 -ARA-A 5

    5 2 2 2 1 2 1 3 - 1 2 1 14 - - - 14 - 2 5 -5

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    ASCE

    GN

    ASCE

    GN

    SANTA FE

    1:16

    1:16

    1:16

    1:4 1:4 1:16

    1:4 1:4 1:16

    1:4 1:4 1:16

    5 2 2 2 1 2 2 - 1 2 1 12 - 2 - 12 - 3 6 -585 13^ 13^ VERTASCE

    5 2 2 2 1 2 2 -585 13^ 13^ VERTASCE

    5 2 2 2 1 2 2 -585 14^ 14^

    5 2 2 2 1 2 2 -585 13^ 13^ASCE

    GN 5^

    VERT

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    2 5 -

    2 5 -

    2 6 -

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 3 FOR RAIL SECTIONSSHEET No. 4 of 7 RA-106

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • REROLLED

    ASCEREROLLED

    Q

    5 2 2 2 -585 15^

    5 2 2 2 1 2 2 -585 13^ 13^ASCE

    5 2 2 2 1 2 2 -585 13^ 13^ASCE

    5 2 2 - - 2 2 -585 13^ 13^

    5 2 2 2 1 2 2 -585 13^ 13^ASCE

    5 2 2 - - 2 2 -585 13^ 13^

    5 2 2 2 1 2 2 -585 13^ 13^ASCE

    5 2 2 - - - 2 -585 13^ 13^

    McCLURE

    Q

    Q

    14^ 5^

    5^

    5^

    5^

    VERT

    VERT

    VERT

    VERT

    1 2 1 11 - 2 - 8 -

    1 2 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    1 2 1 12 - 2 - 12 -

    - 2 1 12 - 2 - 12 -

    2 6 -

    2 4 -

    2 5 -

    2 5 -

    3 6 -

    2 5 5

    2 6 -

    2 5 -

    5 2 2 - - - 2 -585 13^ 13^ 1 2 1 - - - - - 12 - - 2 6 -

    5 2 - - 2 2 -585 13^ 13^ 5^ 1fi 2 1 12 - 2 - 12 - 2 5 -

    5 2 2 - - - 2 -585 13^ 13^ 5^ 1 2 1 12 - 2 - - 12 - 2 5 5

    5 2 2 - - - 2 -585 14^ 5^ 1 2 1 11 - 2 - 8 - 2 6 9

    5 2 2 - - 2 2 -585 13^ 13^ 5^ 1 2 1 12 - 2 - 12 - 2 5 -

    5 2 2 - - 2 1 2 -485 1:4 1:4 1 2fi 1 14 - - - 14 - 2 5 -

    2

    1:16

    15^

    VERT

    5 2 2 2 1 2 2 -580 13^ 13^ 1 2 1 12 - 2 - 12 - 2 6 -ASCE -

    5 2 2 fi 2 - 2 2 -580 13^ 13^ 1 2 1 12 - - - - 3 7 -ASCE -

    5 2 2 2 1 2 2 -580 14^ 14^ 1 2 1 10 - 2 - - 2 4 -5^

    5 2 2 2 1 2 2 -580 13^ 13^ 1 2 1 12 - 2 - - 2 5 -ASCE -

    5 2 2 2 1 2 2 -580 14^ 14^ 1 2 1 10 - 2 - - 2 4 75^

    5 2 2 2 1 2 2 -480 14^ 14^ 1 2 1 12 - 2 - - 2 4 7-

    GN

    GN

    GN

    12

    12

    12

    12

    12

    5 2 2' 2 1 2 2 -575 14^ 14^ 1 2 1 10 - 2 - - 2 4 75^GN 12

    75ASCE

    75ASCE

    75ASCE

    4 2 2 2 1 2 2 -4 13^ 13^ VERT

    4 2 2 2 1 2 2 -4 13^ 13^ VERT

    4 2 2 2 1 2 2 -4 13^ 13^ VERT

    1 2 12 -

    1 2 12 -

    1 2 12 -

    2 - -12

    2 - -12

    2 - -12

    2 4 -

    2 4 -

    2 4 4

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 4 FOR RAIL SECTIONSSHEET No. 5 of 7 RA-107

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • 75ASCE

    75ASCE

    75

    75

    75ASCE

    75ASCE

    75

    75ASCE

    75ASCE

    75

    GN

    GN

    REROLLED

    REROLLED

    4 2 2 2 1 2 2 -4 13^ 13^ VERT

    4 2 2 2 1 2 2 -4 13^ 13^ VERT

    5 2 2 2 1 2 2 -4 14^ 14^ 6^

    4 2 2 2 1 1 2 -4 13^ 13^ 6^

    4 2 2 2 1 1 2 -4 13^ 13^ VERT

    4 2 2 2 1 1 2 -4 13^ 13^ VERT

    4 2 2 2 1 1 2 -4 13^ 13^ VERT

    4 2 2 2 1 1 2 -4 13^ 13^ VERT

    4 2 2 2 1 - -4 15^ 15^ VERT 2

    4 2 - - - - - -4 15^ 15^ VERT 2

    1 2 1 12 -

    1 2 1 12 -

    1 2 1 10 -

    1 1 1 10 -

    1 2 1 12 -

    1 2 1 12 -

    1 2 1 12 -

    1 2 1 12 -

    1 2 1 18 -

    - 1 1 - -

    2 - -12

    2 - -12

    2 - -12

    1 - -8

    2 - -12

    2 - -12

    2 - -VERT

    2 - -12

    - - -

    - - - - - - --

    VERT

    3 6 -

    2 5 -

    2 4 7

    2 4 7

    2 5 -

    2 5 5

    2 5 5

    2 6 -

    2 6 -

    - 2 6 --

    4 2 2 2 1 2 -470 1 2 1 2 - - 2 6 -- 2ARAB

    70ASCE

    70ASCE

    70ASCE

    70ASCE

    70ASCE

    70

    65ASCE

    LA ST.L

    65ASCE

    65ASCE

    65ASCE

    65ASCE

    65ASCE

    65ASCE

    13^ 13^

    4 2 2 2 1 24 13^ 13^ VERT -2

    4 2 2 2 1 24 13^ 13^ VERT -2

    4 2 2 2 1 24 13^ 13^ VERT -2

    4 2 2 2 1 24 13^ 13^ VERT -2

    4 2 2 2 1 24 13^ 13^ VERT -2

    4 2 2 2 1 24 13^ 13^ VERT -2

    - 1212

    1 2 1 2 - - - 1212

    1 2 1 2 - - - 1212

    1 2 1 2 - - - 1212

    1 2 2 - - - 1212

    1 2 2 - - - 1212

    1 2 2 - - - 1212

    2 4 -

    2 5 -

    2 5 -

    2 5 -

    2 5 -

    2 5 -

    4 2 2 2 1 14 13^ 13^ VERT -2 1 1 1

    1 - -

    -

    12

    12

    2 5 -

    4 2 2 2 1 14 13^ 13^ VERT -2 1 1 1 -12

    4 2 - - - -4 - 15^ 15^ -2 - 1 1 ----

    4 2 2 2 1 -4 13^ 13^ VERT -2 1 1 -12

    4 2 2 2 1 -4 13^ 13^ VERT -2 1 1 -12

    4 2 2 2 1 14 13^ 13^ VERT -2 1 1 1 -12

    4 2 2 2 1 24 13^ 13^ VERT -2 1 1 1 -12 1 - - 12 2 5 -

    1 - - 12 2 5 5

    1 - - 12 2 5 5

    - - - - - - -- - 2 6 -

    1 - - 12 2 5 -

    1 - - 12 2 5 -

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 5 FOR RAIL SECTIONSSHEET No. 6 of 7 RA-108

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • PORT

    GUICHON

    MOODYVILLE

    WEYER-

    HAUSERBLOCK &

    POLLAK

    60

    60D&W

    60

    60

    60

    60ASCE

    60

    60

    60

    60

    60

    ST.PM&M

    SCON&W

    SCON&W

    4 2 2 2 1 14 14^ 14^ -2 1 - - - 1 - - - - - -- 10

    4 2 2 2 1 14 13^ 13^ -2 1 1 1 -5^ 10

    4 2 2 2 1 14 13^ 13^ -2 1 1 1 -- 10

    4 2 2 2 1 14 fl 13^ 13^ -2 1 1 1 -- 12

    4 2 2 2 1 1fl4 fl 13^ 13^ -2 1 1 -- 12

    4 2 2 2 1 1fl4 fl 13^ 13^ -2 1 1 1 -- 12

    4 2 2 2 1 14 14^ 14^ -2 1 1 1 -- 12

    4 2 2 2 1 14 14^ 14^ -2 1 1 -- 12

    4 2 2 - - 14 13^ 13^ -2 1 1 1 -- 10

    4 2 2 - - 14 - 12^ 12^ -2 1 1 1 -- 10

    4 2 2 - - 14 - 12^ 12^ -2 1 1 1 -- 10

    1 - 8 8 2 6 -

    1 - 8 8 2 4 -

    2 - - - 12 12 2 5 -

    2 - 12 12 3 5 -

    2 - 12 12 2 4 -

    1 - 8 8 2 5 -

    1 - 8 8 3 5 -

    1 - 8 8 2 6 -

    1 - 12 12 2 6 -

    1 - 12 12 2 4 -

    ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

    RAIL SECTION

    LBS PER YDTYPE A B B1 C D E E1 F G G1 G2 H K K1 L M N O O1 O2 P R S S1 S2 T T1 U U1 V W X

    1-4-06

    NONE

    RGT

    4-27-07 CHART 6 FOR RAIL SECTIONSSHEET No. 7 of 7 RA-109

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

    WORN RAIL PROFILE

    VERTICAL HEAD WEAR

    HORIZONTAL

    HEAD WEAR

    TO MEASURE RAIL WEAR:

    1.) MEASURE HEAD WIDTH AT A POINT 5/8" BELOW THE TOP OF RAIL.2.) MEASURE RAIL AT REGULAR INTERVALS FOR EXCESSIVE WEAR.3.) TAKE MEASUREMENTS AT THREE LOCATIONS IN CURVES TO AVOID ISOLATED READINGS.

    112 LB.

    115 LB.

    119 LB.

    132 LB.

    RAIL WEIGHT NEW RAILHEAD WIDTH

    NEW RAILHEIGHT

    TRANSPOSE WHENHEAD WIDTH ISBETWEEN

    DO NOT TRANSPOSEWHEN RAIL HEIGHTIS LESS THAN

    WEAR LIMIT

    HEAD WIDTH

    RAIL HEIGHT

    5/8"

    WEARWEAR

    RAILHEIGHT

    HEADWIDTH

    2" - 2"

    2" - 2"

    2" - 2"

    2" - 2"

    2" - 2"

    2" - 2"

    7"

    7"

    7"

    6"

    6"

    6"2"

    2"

    2"

    3"

    2"

    3"141 LB.

    136 LB.

    "

    "

    "

    1"

    1"

    1"

    5"

    5"

    6"

    1"

    6"

    6"

    6"1"

    "

    "

    "

    1"

    1"

    2"

    2"

    2"

    1"

    1"6"

    6"

    6"

    6"

    6"

    6"

    4-21-06

    NONE

    DLL

    4-27-07RAIL WEAR LIMITS

    RA-110

  • NOTES:

    A A

    1"

    ITEM

    NUMBER

    BOLT

    DIA.

    MIN. MAX.

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    1"

    FOR USE WITH VARIOUS SIZE TRACK BOLTS

    A

    SPRING WASHER TO CONFORM TO CURRENT AREMA SPECIFICATIONS.

    1-4-06

    NONE

    RGT

    4-27-07LOCK WASHER

    RA-111

    1001261

    1001271

    1001281

    1001291

    1001301

    APPROVED BY:

    CHIEF ENGINEER

    DATE: DRAWING NO.

    K.C.S.STANDARDS SCALE:

    REV:

    DRAWN BY:

  • " x 5" TRACK SPIKE

    NOTES:ITEM NO.

    MO/YR

    ID

    MO/YR

    ID

    1" 1"


Recommended