Keller America Inc User’s Guide Rev. 07/19 Table of ContentsI. CompanyInformation..................................................................................2II. ContactInformation……......……………………………………………………………………..2III. ProductApplicability.………....………………………………………………………………….2IV. ProductOverview…………………………………………………………………………………….3V. Lightning/SurgeProtection.………………………………………………………………………4VI. Options/Accessories.………………………………………………………………………………5VII. Installation……....………………………………………………………………………………………6VIII. Useandcare...…………….…………………………………………………………………………..8IX. TermsandConditions…....…………………………………………………………………………9X. Appendix a. Generic2-wireCurrentLoopConfiguration………………………………A-1 b. Generic3-wireVoltageOutputConfiguration…………………………..A-1 i. Econoline 1. 4-20mA,Cable..................………………………………….......A-2 2. 4-20mA,mPmConnector..................………………………A-2 3. 0.5-4.5VDC,Cable................…………………………………..A-2 4. 0.5-4.5VDC,mPmConnector................……………………A-2 ii. Valueline 1. 4-20mA,Cable................…………………………………………A-3 2. 4-20mA,DIN43650Connector................…………………A-3 3. 4-20mA,MIL-C-26482Connector.................……………A-4 4. 0-5/10VDC,Cable.................……………………………………A-3 5. 0-5/10VDC,DIN43650Connector..................……………A-3 6. 0-5/10VDC,MIL-C-26482Connector.................………..A-4 iii. Preciseline 1. 4-20mA+RS485,Cable................…………………………….A-5 2. 0-5/10VDC+RS485,Cable.................………………………..A-53.SDI-12+RS485,Cable.........................................…………A-5 4. 4-20mA+RS485,MIL-C-26482Connector...................A-6 5. 0-5/10VDC+RS485,MIL-C-26482Connector.....………..A-6 6. SDI-12+RS485,DIN43650Connector........................…A-5 iv. Levelgage 1. 4-20mA,Cable................…………………………………………A-7 2. 0-5/10VDC,Cable.................………………………………….…A-7 v. LevelRat 1. 4-20mA+RS485,Cable..............………………………………A-7 2. 0-5/10VDC+RS485,Cable..............…………………………A-7 vi. Acculevel 1. 4-20mA+RS485,Cable.………………..............………………A-7 2. 0-5/10VDC+RS485,Cable..............…………………………A-7 3. SDI-12+RS485,Cable..................................................A-8 vii. Microlevel/Nanolevel 1. 4-20mA+RS485,Cable...………………………………...........A-8 c. SubmersibleLevelTransmitters i. InstallationTips.………………………………………..……………A9-11
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
IV. Product Overview - Level Transmitters
Acculevel-TheAcculevelfromKellerisahighaccuracysubmersibleleveltransmitter.IncorporatingallofthefeaturesoftheLevelgageincludingtheNSF61andNSF372certifications,theAcculevelhasadditionalfeaturesthatprovideenhancedfunctionality,includingdualoutputs;i.e.,oneanalog(4…20mA,0…5VDC,0…10VDC)andonedigital(RS485).TheRS485interfaceprovideslevelandtemperatureinformationandallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.Additionally,theAcculeveliscapableofgreateraccuracythantheLevelgage,withastandardaccuracyof0.25%BRTEBandanoptional0.1%BRTEB.TheAcculevelcanbemanufacturedin316Lstainlesssteelortitaniumforincreasedresistancetocorrosion,notablyfromseawater.
Acculevel SDI -TheAcculevelSDIisaversionoftheAcculevelhighaccuracysubmersibleleveltransmitterthatisavailablewithSDI-12orRS485digitalcommunicationprotocols.Itisavailablewithstandardaccuracyof±0.1%FSTEBinrangesupto900ftWCandoptionalUSGSOSWaccuracyforrangesupto70ftWC.TheAcculevelSDIcanbemanu-facturedinstandard316Lstainlesssteeloroptionaltitaniumforincreasedresistancetocorrosion,notablyfromseawater,carriestheNSF61andNSF372approvals.
Levelgage-TheKellerLevelgageisageneralpurposesubmersibleleveltransmitteravailablein1%and0.5%BRTEBaccuracy.Constructedfrom316Lstainlesssteel,itisideallysuitedformostfreshwatermonitoringapplications.Withstandardconstruction(i.e.EPDMandXLPE)materials,theLevelgagehasbeencertifiedtoNSF61andNSF372standardsforuseindrinkingwater.Itisavailableincustomrangesfrom0…3ftWCto0…900ftWC.Cablelengthsarecuttouserspecifications.TheLevelgageisalsoavailableinvariousoutputconfigurations,including4…20mA,0…5VDC,and0…10VDC.
LevelRat -TheKellerLevelRatisspecificallydesignedtoprovide0.5%BRTEBaccuracyforlevelindicationingrease-ladenenvironmentscommonlyfoundinliftstationsservingcommercialconcerns.TheLevelRatdesigntakesastepawayfromthelargeandbulkyprotectioncagedesignsbyutilizingauniquediaphragmmaterialthatoffersthenon-stickpropertiesofTeflonandprovidesaddedresistancetodamagefromdebris.TheLevelRatprovidesdualoutputs;yourchoiceofanalogoutputs(4…20mA,0…5VDC,or0…10VDC)plusonedigital(RS485)forlevelrangesfrom0…5ftWCto0…100ftWC.
Microlevel-TheMicrolevelcombinesthecapabilityoftheAcculevelwithaclassleading0.63”(16mm)outsidediameter.TheMicrolevelisavailableinfullscalerangesfrom0…3ftWCthrough0…900ftWCandprovides0.25%BRTEBaccuracy.LiketheAcculevel,italsoprovidesboth4…20mAanalogandRS485Digitaloutput.TheRS485interfaceprovideslevelandtemperatureinformation.Italsoallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.
Nanolevel-TheNanolevelisuniquelydesignedforhighaccuracymeasurementofverylowpressureranges.TheNanolevelisavailableinfullscalerangesfrom0…4inWCthrough0…10ftWCandisavailablewithstandardaccuracy0.25%BRTEBand0.1%BRTEBoptional.LiketheAcculevel,italsoprovidesboth4…20mAanalogandRS485Digitaloutput.TheRS485interfaceprovideslevelandtemperatureinformation.Italsoallowstheusertorescaletheanalogoutputfrom10…110%ofthebasicrange.
Page3
I. Company Information
KellerAmericaIncistheNorthAmericansubsidiaryofKellerAGfürDruckmesstechnik,whichcontinuesastheleaderinlevelandpressuresensing.Fromhumblebeginnings,Kellernowprovidesitsproductsandexpertisethroughaworldwidenetworkoffacto-ry-trainedprofessionals.
Withtheadventofinexpensive,miniaturizedmicroprocessors,Kellercontinuestoad-vancethestate-of-the-artinfullypackagedpressuretransmitters,withTotalErrorBandperformancenotpossiblejustafewshortyearsago.Annualsensorproductionnowexceeds1millionpieces.
DoingbusinesswithKelleriseasyandmostinquiriesareansweredwithin24hours.StandarddeliveryonU.S.-assembledproductsis3daysARO.Weofferconvenienttermswithapprovedcreditandacceptmostmajorcreditcards.
AtKeller,providingcustomerswithsuperiorvalueisawayoflife.
II. Contact Information
KellerAmerica,Inc.351BellKingRdNewportNews,Virginia,23606P:877-253-5537F:757-596-6659Web: www.kelleramerica.comEmail: [email protected]
III. Product Applicability:Unlessotherwisenoted,thismanualcontainsuserinformationforthefollowinglevelandpressureinstrumentationprovidedbyKellerAmerica:Acculevel™,Levelgage™,LevelRat™,Microlevel™,Econolevel™,andNanolevel™submersibleleveltransmitters;Econoline™,Valueline™,andPreciseline™abovegroundpressuretransmitters.
Electronic copies of this user’s guide can be found at: http://www.kelleramerica.com/manuals-and-software/manuals/Keller_America_Users_Guide.pdf
Page2
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
VI. Options /Accessories:
Titanium Construction -OptionalfortheAcculevelandPreciseline.Highlyrecommend-edforbrackishandseawaterapplications.
External Surge Protector-Recommendedforlightning/surgeprotectionofuser’spowersupply/readout/PLC,etc.TobeusedinconjunctionwithLevelgage,Acculevel,LevelRat,Econolevel,Microlevel,Nanolevel,Valueline,orPreciselinetransmitters.
½” NPT Pipe conduit fitting -½”NPTmalefitting,allowsrigidmountingto½”conduitforLevelgage,Acculevel,orLevelRatsubmersibletransmitters.ItcanalsobeaddedtoourPreciselineandValuelinepressuretransmitters.
Drying Tube Assembly-Cleartubefilledwithindicatingdesiccant,attachesdirectlytocableventtube,interceptswatervapor.Highlyrecommendedwhenoperatingisinhighhumidityconditions.Mustbeperiodicallyrenewedasdesiccantbecomessaturated,turningcolorfromblue(dry)topink(saturated).
Bellows Assembly-Alternativetothedryingtube,thisaneroidbellowsattachestocableventtubeandrequiresnoperiodicmaintenance.Notethattheuseofthebellowsresultsinaclosedreferencepressuresystemsubjecttozeroshifterrorsinducedbychangingtemperaturesofupto0.0004psi/ºC.Notrecommendedforusewithaccuracyrequirementsof±0.25%FSorbetter,orranges<2psi.
Electrical Connectors -mPm393isoptionalfortheEconoline,DIN43650andMIL-C26482areoptionalforValuelineandPreciseline.ThemPm393andMIL-C26482matingconnectorsfeaturesoldercupswhiletheDIN43650incorporatesscrewterminals.
RS485 Converter/Cable -FortheuserwhowishestocommunicatewiththeirAcculevel,LevelRat,Nanolevel,Microlevel,orPreciselinetransmitterviatheRS485digitalinterface.AvailableinRS232andUSBversions,alongwithcableadapters,asneeded,andCCS30Software(alsoavailablefordownload,freeofchargefromwww.kelleramerica.com).Consultfactoryfordetails.
Termination Enclosure-Convenientoptioncomplementinggauge-typepressure/leveltransmitters,whereitisdesiredtoterminatethetransmittercableclosetothemea-surementpoint.ItincludesaNEMA4Xclearfrontenclosure(7.9X4.7X3.5inches)withtwo,liquid-tightcablefittings(onein,oneout),aterminalstrip,andampleroomformountingadryingtubeorbellowsassembly.
Stabilizing Weight-ZincpropshaftanodeadaptedtofitØ21mmO.D.ofLevelgage,Acculevel,andLevelRatsubmersibleleveltransmitters.Aidsincorrosionresistanceaswellashelpsensurethatthecableremainstautinturbulentconditions.
Cable Hanger-Singleeyefor0.230”diametercable.Designedtogripthecablejacketandprovideasuspensionpointforinstallationofcabledtransmitters.
Pressure Test Adapters -Designedtofacilitatecalibrationandmaintenancetesting,thesespecialtyadaptersallowforconnectionofthevariousKellerleveltransmitterstoapressurecalibrator.
Page5
Econolevel-TheEconolevelbyKellerisalowcostgeneralpurposesubmersibleleveltransmitterdesignedforhighvolumeapplications.Itisavailableinnominalpressurerangesfortankandwelllevelmonitoringapplications.TheEconolevelprovidesa4…20mAanalogoutputthatiscompatiblewithmostSCADAsystemsandPLCs.Mini-mumorderquantitiesapply.
IV. Product Overview cont’d - Pressure Transmitters
Econoline-TheEconolinebyKellerisalowcostgeneralpurposepressuretransmitter.Itisavailableinnominalpressurerangesbetween5psiand10,000psiandwithathreaded¼”NPTpressureconnection.Idealfortankandpipepressuremonitoringapplication,itprovideseither4…20mAor0.5…4.5VDC(ratiometricornon-ratiometric)analogoutputsthatarecompatiblewithmostSCADAsystemsandPLCs.
Valueline-TheValuelinebyKellerisahighlyversatileandaccuratepressuretransmitter.Itisavailableincustompressurerangesfrom0…2through0…15,000PSIandyourchoiceofelectricalconnectionsincludingattachedcable,DIN43650,andMIL-C-26482connec-tors.Theattachedcableversionisfullysubmersible,makingittheidealchoicewheninstalledinavalvepitorotherenvironmentpronetoperiodicflooding.TheValuelinealsocarriestheNSF61andNSF372approvalsfordrinkingwaterapplications.
Preciseline -ThePreciselineisourmostaccurateabove-groundpressuretransmitter.Withstandardaccuracyof0.25%BRTEBandoptional0.1%BRTEB,a¼”NPTpressureconnection,anddualoutputs(analoganddigital)thePreciselineoffersversatilityindesignandapplication.LiketheAcculevel,theanalogoutputcanberescaledviatheRS485interface.TheRS485interfacealsoallowstemperaturedatatoberetrievediftheapplicationdemands.LiketheValueline,thePreciselineisincludedintheNSF61and372approvals.
Preciseline SDI-ThePreciselineSDIishighlyprecisepressuretransmitterthatisavail-ablewithSDI-12orRS485digitalcommunicationprotocols.Itisavailablewithstandardaccuracyof±0.1%FSTEBinrangesupto900ftWCandoptionalUSGSOSWaccuracyforrangesupto70ftWC.ItcomeswithyourchoiceofattachedcableorMIL-C-26482connectorelectricalconnections.Thecableversionisfullysubmersible,makingittheidealchoiceinenvironmentspronetoperiodicflooding,whiletheNSF61andNSF372approvalsmakethePreciselineSDIsuitableforuseindrinkingwaterapplications.
V. Lightning / Surge Protection:
Asofthiswriting,Kelleristheonlypressure/leveltransmittermanufacturerintheworldtoprovide,atnoadditionalcharge,alifetimewarrantyagainstdamagecausedbylight-ningand/orelectricalsurge.Thisguaranteeappliestothe4…20mAoutputversionofthefollowingproducts:Levelgage,Acculevel,LevelRat,Microlevel,Valueline,andPreciseline.Thiswarrantyapplieseveninthecaseofadirectlightningstrike.Theuser’sliabilityislimitedtoshippingcoststoKellerAmerica.
Page4
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
Thecalculationsbelowareusefulinidentifyingtheminimumsupplyvoltageneededforacurrentloopwithadditionallineimpedancesorconversely,themaximumcurrentloopimpedanceallowedforagivensupplyvoltage.
Minimumsupplyvoltagewithlightningprotectionoptioninstalled: 11VDC+(Totalloopimpedancex0.022)
Minimumsupplyvoltagewithoutlightningprotectionoptioninstalled: 8VDC+(TotalloopImpedancex0.022)
Maximumallowableloopimpedancewithlightningprotectionoption installed: (SupplyVDC–11VDC)/0.022
Maximumallowableloopimpedancewithoutlightningprotectionoption installed: (SupplyVDC–8VDC)/0.022
Transmitter Anchoring-ItisrecommendedthatKellersubmersibletransmittersbeinstalledinastillingwellorattachedtorigidconduitviaaconduitfittingintegraltothetransmitter,inordertopreventdamagetothetransmitterfromimpactwithimmovableobjects.Itisnotadvisabletotiethetransmittertoapumportopiping,asanyproblemwiththetransmittercouldrequirethatthepumpbepulledfromtheinstallation.
Someapplicationsrequirethetransmittertobesuspendedwithoutaprotectivestillingwellorconduitattachment.Inallinstallations,careshouldbetakentopreventdamagetothesubmersiblecable.
Transmitter Submersion -Damagetosubmersiblecablecanleadtofailureofthetrans-mitter.Kelleremploysaruggedcablejacketmaterialstominimizetheriskofcutsandabrasion.Still,takecarewhenloweringyourtransmitterintothewell,makingsurethecabledoesnotdragoversharpedges.Avoiddroppingthetransmitterfromthesurface.Donotsubmergeelectricalconnectionendofcable.
Condensation protection -Kellerhasoptimizedthesizeofthecableventtominimizetheoccurrenceofwatervaporincursion.Inareasofhighhumidity,itmaybedesirabletouseaDryingTubeAssembly(desiccant)orBellowsAssemblytopreventwatervaporfromenteringtheventtube.ContactKellerAmericafororderinginformation.
Bending of Cable-Ourjacketedcableisquiteflexible.However,caremustbetakentoensuretheventtubeintegraltothecableisnotcrimpedwhenbendingthecabletosuityourinstallation.Itisrecommendedthatthecablenotbebenttoaradiussmallerthan1inch.
Cable Compression -Manyusersemployacompressionfittingtosecureourcableasitentersajunctionbox.Caremustbetakenthatthefittingisnotovertightened,causingdamage to the cable and/or crimping the vent tube.
Page7
Digital Display / Meter -TheTRIDENTdisplaybyPrecisionDigitalisaversatileandcosteffectiveprocessmeterprovidinganeasytouseandreaddisplay/controllerforyourlevelandpressuremeasurementapplication.Formoreinformationandtechnicalsup-port,pleasecontactPrecisionDigitalat(800)343-1001oronlineatwww.predig.com.
VII. Installation:
Thefollowingisimportantinstallationandgeneralmaintenanceinformationforsub-mersibletransmitters.PleasecontactKellerAmericaforadditionalinstruction.
Supply Voltage-Adequatesupplyvoltageiscriticaltoensureproperoperationof4-20mApressureandleveltransmitters.Withouttheminimumrequiredvoltageavailableatthetransmitter,thetransmitterwillnotoutputthecorrectanalogvalue.
Manyanalogtransmitterswillappeartooperateproperlyevenwhenthesupplyvoltageisnotadequatetopowertheloopwhenthetransmittershouldbeoutputting20mA.Forexample,a10voltsupplymayappeartobeenoughtopowerananalogtransmitterwhenitisoutputting4mAwithzeropressureapplied,butasthetransmitter’soutputincreaseswithincreasingpressure,voltagedropsacrossotherdevicesintheloop(ana-loginputdevices,cableand/orexternalbarrierdevices)mayreducethesupplyvoltagetothetransmitterandpreventitfromprovidingthecorrectoutputaboveacertaininputpressure/levelthreshold.
KellerAmerica’s4-20mApressureandleveltransmittersfeaturemicroprocessorbasedsignalconditioning.Duringpowerup,thecircuitperformsachecksequencewhichde-termineswhetherthereissufficientsupplyvoltagetopoweralldevicesontheloop,bysettingtheoutputto~110%ofthemaximumvalue,i.e.,~22.5mA.Ifthesupplyvoltageisnotsufficienttosupply22.5mAtothecircuit,thenthemaximumpossiblecurrentwillbeseenontheanalogoutput,e.g.,17mA,andthetransmitterwillnotinitiatenormaloperation.
Thebenefitofthistechnologyisthattotalloopimpedanceisaccountedforpriortoplacingtheequipmentintoservice,preventingfalseindicationswhenthevoltagesupplyisinsufficienttosupporttheloopwithmaximumpressureapplied.
Mostcurrentloopscontainanaloginputdevices,indicatorsorothercomponentshavinginputimpedanceswhichmustbeconsideredwhencalculatingthesupplyvoltagesneed-ed.Forexampleananaloginputdevicewitha250OhmInputImpedancewillrequireanadditionalvoltageof5.5VDC(250x0.022=5.5)inadditiontotheminimumsupplyvoltagenecessaryforthetransmittertooperateproperlyovertheentirerange.
Page6
Total LoopImpedance
IndicatorAnalog Input
Device
Cable
ResistanceIS Barrier
4 - 20mA outputLevel / Pressure
Transmitter
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
theinput/nosecaptothedeviceisclear.Finishbystirringinfreshwater.Wipedrywithasoftragortowel.
Asoapscumandhard-waterstainremovermayalsobeused,ifnecessary,butonlyaftercompatibilitywithanyo-ringsealsintheKELLERproductisdetermined.Followthesolventmanufacturer’srecommendationsforsafehandling.
IX. Terms and Conditions:
Offers -Unlessotherwiseindicated,thepricessetforthinthisquotationarevalidfor60daysfromthedateofthequotationandapplytoproductsthatarescheduledforship-mentwithintwelvemonthsfromthedateoftheBuyer’spurchaseoratKellerAmerica,Inc.shippingcapabilitiesatthetimetheorderisentered,whicheverislater.
Acceptance of order-Anypurchaseordertobeacceptedhastorefertoaquotation,whetherdeliveredbysurfacemail,e-mailorfacsimile.Alloralordersmustbeconfirmedinwriting.Byreferringtothisquotation,BuyeracceptsandadoptstheGeneralTermsandConditionsofSale(“TermsandConditions“)totheexclusionofanyadditionalordifferenttermsappearinginBuyer’spurchaseorderandwaivesanyrightBuyermayhavetoenforceanysuchadditionalordifferentterms.OurConfirmationofOrderorInvoicevalidatesorders.Ordersforcustom-configuredproductsarebuilttoyourspecifi-cationandthereforemaynotbecanceledoncetheorderhasbeenconfirmed.
Date of shipment-TheestimatedshippingcapabilitystatedonthequotationisgivensolelyfortheBuyer’sinformationanddoesnotconstituteacommitmenttodeliverproductsinaccordanceherewith.Buyermayrequestaspecificshippingdateorshippingschedule.KellerAmerica,Inc.willscheduleshipmentsbaseduponBuyer’srequestandKellerAmerica,Inc.’sshippingcapabilitiesatthetimeBuyer’spurchaseorderispro-cessed,atwhichtimeKellerAmerica,Inc.willissuetoBuyeraformalAcknowledgmentofOrderthatwillindicatetheestimatedshippingdate(s).Aftertheshipmentshavebeenscheduled,BuyermaynotcancelorpostponeascheduledshipmentunlessBuyersub-mitsitsrequestinwritingandKellerAmerica,Inc.consentsbyissuinganewacknowl-edgment.
Anyrequesttocancelortorescheduletheshipmentthatisreceivedlessthan21daysfromthedatescheduledfortheshipmentoftheproductscoveredbytherequestmayberejectedasuntimely,ormaybeaccepteduponpaymentofthecancellationchargeof20%orareschedulingchargeof10%ofthesalespriceshownonthisquotationatKellerAmerica,Inc.’soption.KellerAmerica,Inc.willuseitsbesteffortstoshiponorevenbe-foretheestimatedshippingdatesindicated,butwillnotbeliableforanydelayorfailuretodeliver.KellerAmerica,Inc.shallnotbeliableforanyspecial,incidentalorconsequen-tialdamagesresultingfordeliverydelaysorinabilitytodeliver. AllgoodsormaterialssuppliedbyKellerAmerica,Inc.remainitspropertyuntiltotalpay-mentisreceived.AllsuchgoodsandmaterialsareatthesoleriskoftheBuyerandintheeventofbeingdamaged,destroyedorlostafterdelivery.KellerAmerica,Inc.isentitledtoreceivethetotalpaymentofthosegoods.
Page9
Position Sensitivity-Thetransmittershouldbeinstalledinaverticalposition,other-wiseitmayexhibitanoffset.Ifthetransmittermustbeinstalledinanypositionotherthanvertical,measuretheoutputwithnopressureappliedpriortoconnectiontoyourdisplay,PLC,orcontroller.Usethemeasuredvalueforyourzeropoint.
VIII. Use and Care:
Safe Handling-SafehandlingofKELLERpressuremeasurementdevicesisaccomplishedifanominalamountofcareistaken.Thingstoavoidare:•Sharpimpactagainsthardsurfaces•Contactwithchemicalsknowntobecorrosivetothematerialsofconstruction•ProbingofpressuresensingmembranewithANYTHING
Limits of Pressure -KELLERpressuresensors,transducersandtransmittersaredesignedtowithstandacertainamountofoverpressurewithoutdamageorcalibrationshift.Itcanrangefrom15Xforthelowerpressurerangesto1.1Xforthehighestranges.Thisvalueisdifferentforeachproductandisreferredtointheproductliteratureas“Overpressure”.Itistheuser’sresponsibilitytoensurethattheproperKELLERproductischo-senfortheparticularpressureconditionsexpected.
Environmental conditions-EachKELLERproductisdesignedtobecompatiblewithaparticularenvironment.Itistheuser’sresponsibilitytoensurethattheKELLERproductisnotexposedtoanenvironmentalconditionforwhichitisnotdesigned.Thesecondi-tionscanincludeoperatingtemperaturerangeandexposuretohigh-pressurewaterjets,medianotcompatiblewiththematerialsofconstruction,submergenceoftransmittersnotdesignedforthatpurpose,orpotentiallyexplosiveatmospheres.AKELLERengi-neercanhelptheuserdeterminethecorrectchoiceofenclosuretosuittheparticularapplication.
Electrical conditions -EachKELLERproductisdesignedtooperateproperlywithinaspecificrangeofelectricalconditions.Thespecificproductlabeldefinestherating(s),ifany,thatappliestotheproducttowhichitisaffixed.Alltransmittersaredesignedtowithstandreversepolarityaswellasovervoltagetoacertainextent.Itistheuser’sresponsibilitytoensurethatallelectricalconnectionsaremadetotheKELLERproductsinaccordancewithKELLERrecommendationsaswellaslocalelectricalcode.Wirecolorsorconnectorpin-outsareeitherprintedonthelabelaffixedtotheproductorprovidedseparately.
Cleaning-WARNING!Undernocircumstancesshouldthemembrane,pressureinputport,ornosecaptotheKELLERdevicebeprobedwithanyobject.Damagetothesens-ingmembraneispermanentand,inmostcases,requiresrepairorreplacement.
Regardingmedia-isolatedproducts,shouldthepressureinputornosecaptothesensor,transducer,ortransmitterbecomefouled,itmaybecleanedinthefollowingmanner:
Thedeviceshouldbeslowlyloweredmembrane-endintoasolutionofwarm,soapywater.Careshouldbetakennottosubmergetheentiredevice,unlessitisspecificallydesignedforcontinuoussubmergence.Agitateinthesolutionfor20-30secondsoruntil
Page8
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
uponpaymentofalltravelexpensesbyBuyer.
WarrantyperiodfortheLevelgage,LevelRat,Acculevel,Microlevel,Preciseline,andVal-uelineproductsis24(twenty-four)monthsfromdateofshipment.Warrantyperiodforallotherproductshereinis12(twelve)monthsfromdateofshipment.Warrantyrepaircoversallapplicablepartsandlabor.Thiswarrantyisgiveninlieuofanyotherwarranty,expressorimplied.KellerAmerica,Inc.explicitlydisclaimsanyimpliedwarrantiesofmerchantabilityandfitnessforaparticularpurpose.Therearenowarranties,expressorimplied,thatextendbeyondthedescriptionherein.ThesoleandexclusiveremedyforanyclaimsagainstKellerAmerica,Inc.shallbethewarrantydescribedinthisdocument.Alldamages,directorconsequential,limitedtothedescribedwarrantyareexcluded.
Repairs-UnlessotherwiserequestedinwritingbytheBuyer,allproductsreturnedtoKellerAmerica,Inc.underthetermsofthewarrantywillbecheckedandanalyzedinor-dertodeterminethecauseofthedefault(s)claimedbytheBuyer.AreportwillthenbesubmittedtotheBuyerpointingoutthenatureofthedefault(s),thepartyresponsibleforthedefault(s)andthequotationoftherepair,ifneeded.Forfurtherrepairinstruc-tionsgotowww.kelleramerica.com.
Complaints-AllclaimsordisputesmustbemadeinwritingtoKellerAmerica,Inc.amaximumof60daysfromreceiptofthegoods,includingdiscoveryoffaultsnotpre-viouslyapparent.Ifthewarrantyclaimsarejustified,KellerAmerica,Inc.isfreeatitsdiscretiontorepair,replaceorissuecredit.Nofurthercompensationfordamageswillbemade.
AnydisputesorclaimsofBuyermustbeinitiatedinapropercourtorotheradjudicativebody,asapplicable,withinone(1)yearfromthedateofshipmentbyKellerAmerica,Inc.,oritsrepresentative(s),orsuchclaimshallbedeemedinvalidorexpiredandcannotberenewed.Totheextentallowed,thislimitationperiodshalltrumpanyapplicablestatutorylimitationsperiodthatmaystatealongerperiod.
Limitation of responsibility -Ourresponsibilityconcernsthecorrectfunctionofourproductsonly.Itcannotbeextendedtothewholesysteminwhichtheyareused.Ourresponsibilityislimitedtothereplacement,repairorreimbursementofthegoodsweagreearedefectiveornon-conforming.Theclaimmustbeinwritingwithin60daysfromreceiptofthegoods.
Place of jurisdiction / applicable law -ThecontractmadebyacceptanceofthisoffershallbedeemedmadeintheStateofVirginiaandshallbegovernedbyandconstruedinaccordancewiththelawsofthatstatewithoutreferencetoorapplicationofanyconflictsoflawsprinciplesandwithoutconsiderationoftheplaceofexecution.BuyerexpresslyagreestothesubjectmatterandpersonaljurisdictionoftheCircuitCourtsfortheCityofNewportNews,Virginia,orthefederalDistrictCourtfortheEasternDistrictofVirginia,NewportNewsDivision.
Assignment-NeitherthisoffernoranycontractresultingtherefrommaybeassignedortransferredinwholeorpartwithoutthepriorwrittenconsentofKellerAmerica,Inc.
Page11
Price -Unlessotherwisespecifiedinthequotation,ourpricesareinUSdollars(USD).Theyareexclusiveoffreightcostsandofallstateandlocalsales,use,excise,privilegeandsimilartaxes.SuchtaxesimposedonKellerAmerica,Inc.orwhichKellerAmerica,Inc.hasadutytocollectinconnectionwiththesaleordeliveryoftheproductsde-scribedonthequotationshallbepaidbyBuyerandwillappearasseparateitemsontheinvoice.
Shipment / freight -DeliveriesareF.O.B.NewportNews,VA.TitleandriskoflossshallpasstoBuyerupontenderoftheproductsbyKellerAmerica,Inc.toacommoncarrier.InabsenceofspecificwritteninstructionfromBuyer,KellerAmerica,Inc.willselectthecommoncarrier,butKellerAmerica,Inc.shallnottherebyincuranyliabilityinconnec-tionwithshipment.Buyershallberesponsibleforanyfreightcharge.Declaredvalueforeachshipmentwillbeamaximumof$100regardlessoftheactualvalueofthegoods,notwithstandingwritteninstructionsfromtheBuyerspecifyingahigherdeclaredvalue.Iftheproductsareshippedfreightprepaid,BuyershallpayKellerAmerica,Inc.theap-propriatefreightcharges,whichwillbeshownasseparateitemsontheinvoice.
Payment -TermsareindicatedonourConfirmationofOrderandonourInvoices.KellerAmerica,Inc.willsubmitaninvoicetoBuyerforeachshipmentatthetimeofshipment.Exceptasotherwiseprovidedonthequotation,BuyershallpaytheamountinvoicedbyKellerAmerica,Inc.within30daysfromthedateoftheinvoice.IfinthejudgmentofKellerAmerica,Inc.thefinancialconditionorpaymentrecordofBuyeratanytimedoesnotjustifyshipmentunderthepaymenttermsspecifiedabove,KellerAmerica,Inc.mayrefusetoshipunlessitreceivespaymentinadvance,oratitsoption,paymentupondelivery.2%interestpermonthischargedonoverdueaccounts.
Documentation -Theinformationgiveninourdocumentation,printedmatter,datasheetsandpricelistsiswithoutcommitment.Thisinformationspecifiestheproductbutisnowarranty,unlessagreedinwriting.
Warranties -KellerAmerica,Inc.warrantsthattheproductsthatitsellsaredeliveredfreefromdefectsinmaterialandworkmanship.KellerAmerica,Inc.’sliabilityunderthiswarrantyislimitedtoreplacingorrepairingorissuingacreditnote,atitsoption,foranyproductwhichisreturnedtothefactory,transportationchargesprepaid,andwhichisdeterminedbyKellerAmerica,Inc.tobedefective.Thiswarrantydoesnotapplytobatteriesandaccumulatorsandtoanyproductwhichhasbeensubjectedtoordam-agedduetomisuse,misapplication,negligenceoraccident,orwhichhasbeenrepairedoralteredwithoutexpresspriorandwrittenconsentfromKellerAmerica,Inc.Inordertoobtainserviceunderthetermsofthewarranty,BuyermustnotifyKellerAmerica,Inc.ofanydefectsbeforetheexpirationofthewarrantyperiodandmakesuitablearrangementsfortheperformanceofservices.Inallcases,BuyershallberesponsibleforpackagingandshippingtheproductstotheKellerAmerica,Inc.plantwithshippingchargesprepaid.KellerAmerica,Inc.shallpayforthereturnofanyproductstoBuyeriftheshipmentistoalocationwithinthecontinentalUSA.Buyershallberesponsibleforpayingallshippingduties,taxes,andotherchargesforproductsreturnedtoanyotherlocation.KellerAmerica,Inc.willprovideon-siteserviceonlyuponprioragreementand
Page10
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
X: Appendix
+ SUPPLY
OUTPUT/GROUND
2-WIRE
TRANSMITTER
POWER
SUPPLY
DISPLAY/
CONTROL
+
-
-
+
2-WIRE CURRENT LOOP
3-WIRE VOLTAGE OUTPUT
+ SUPPLY
+ OUTPUT
3-WIRE
TRANSMITTER
POWER
SUPPLY
DISPLAY/
CONTROL
+
-
-
+
GROUND
A-1
PleaserefertoSectionVII:Installationforminimumsupplyvoltageinformation.
NoassignmentortransferinviolationofthisprovisionshallbevalidorbindingonKellerAmerica,Inc.
Attorney’s fees-UponanybreachofthisAgreement,thereasonableattorney’sfeesandcostsofthesubstantiallyprevailingparty,whetherbylitigationorsettlement,shallbepaid by the breaching party.
Page12
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
VALUELINE w/ATTACHED CABLE...4-20mA
VALUELINE w/ATTACHED CABLE...0-5...10VDC
VALUELINE w/DIN43650...4-20mA
VIEW OF REAR OF TRANSMITTER
VALUELINE w/DIN43650...0-5...10VDCVALUELINE
+ OUTPUT
VIEW OF REAR OF TRANSMITTER
3
12
3
12
DRAIN
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
DRAIN
BLACK: + SUPPLY
WHITE: GROUND
RED: + OUTPUT
+ SUPPLY
OUTPUT/GROUND
SEE NOTE 1.
+ SUPPLY
GROUND
A-3
12
3
4
12
3
4
DRAIN/CASE GROUND
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
DRAIN
BLACK: + SUPPLY
WHITE: GROUND
RED: + OUTPUT
ECONOLINE w/CABLE...4-20mA
ECONOLINE w/mPm393...4-20mA
ECONOLINE w/CABLE...0,5-4,5VDC
ECONOLINE w/mPm393...0,5-4,5VDC
CASE
+ SUPPLY
OUTPUT/GND
VIEW OF REAR OF TRANSMITTER
CASE
+ SUPPLY
GROUND
VIEW OF REAR OF TRANSMITTER
+ OUTPUT
A-2
NOTES: 1: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
BLUE: RS485A
YELLOW: RS485B
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: GROUND
RED: + OUTPUT
BLUE: RS485A
YELLOW: RS485B
PRECISELINE w/ATTACHED CABLE...4-20mA + RS485
PRECISELINE w/ATTACHED CABLE...0-5...10VDC + RS485
DRAIN (NOTE 1)
BLACK: GROUND
WHITE: SDI-12
RED: + VCC
BLUE: RS485A
YELLOW: RS485B
PRECISELINE SDI w/ATTACHED CABLE...SDI-12+ RS485
A-5
NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
AB
CD
E
F
AB
CD
E
F
+ SUPPLY
OUTPUT/GROUND
VALUELINE W/MIL-C-26482...4-20mA
REAR VIEW OF TRANSMITTER
VALUELINE W/MIL-C-26482...0-5...10VDC
+ SUPPLY
GROUND
+ OUTPUT
REAR VIEW OF TRANSMITTER
E: DRAIN
A-4
NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
NOTES: 1: FOR LIGHTNING/SURGE PROTECTION TO BE EFFECTIVE, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. 2: LIGHTNING PROTECTION NOT AVAILABLE ON ECONOLEVEL. DRAIN WIRE CONECTION NOT REQUIRED. 3: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
LEVELGAGE & ECONOLEVEL w/ATTACHED CABLE...4-20mA
LEVELGAGE w/ATTACHED CABLE...0-5...10VDC
ACCULEVEL & LEVELRAT w/ATTACHED CABLE...4-20mA + RS485
ACCULEVEL & LEVELRAT w/ATTACHED CABLE...0-5...10VDC + RS485
DRAIN (NOTE 1,2)
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: GROUND
RED: + OUTPUT
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
BLUE: RS485A
YELLOW: RS485B
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: GROUND
RED: + OUTPUT
BLUE: RS485A
YELLOW: RS485B
A-7
PRECISELINE w/MIL-C-26482...4-20mA + RS485
REAR VIEW OF TRANSMITTER
PRECISELINE w/MIL-C-26482...0-5...10VDC + RS485
REAR VIEW OF TRANSMITTER
A: + SUPPLY
C: OUTPUT/GROUND
A: + SUPPLY
C: GROUND
B: + OUTPUT
D: RS485A
F: RS485B
D: RS485A
F: RS485B
E: DRAIN
AB
CD
E
F
AB
CD
E
F
PRECISELINE SDI w/MIL-C-26482...SDI-12 + RS485
REAR VIEW OF TRANSMITTER
A: + SUPPLY
C: GROUND
B: SDI-12F: RS485B
D: RS485A
AB
CD
E
F
A-6
NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/ SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
A-9
MINIMUM PIPE BEND RADIUS
Acculevel/ LevelgageØ0.83”
MicrolevelØ0.63”
Schedule40
1”IPS(Ø1.315x0.133”w) 22” 18”
1.5”IPS(Ø1.900”x0.145”w) 4” 5”
2”IPS(Ø2.375x0.154”w) 3” 3”
Schedule80
1”IPS (Ø1.315x0.179”w) 22” 22”
1.5”IPS(Ø1.315x0.200”w) 4” 6”
2”IPS(Ø2.375x0.218”w) 4” 4”
NOTES: 1: FOR LIGHTNING/SURGE PROTECTION TO BE EFFECTIVE, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. 2: DO NOT SUBMERSE ELECTRICAL TERMINATION IN LIQUID. IT WILL DAMAGE THE INSTRUMENT.
MICROLEVEL & NANOLEVEL w/ATTACHED CABLE...4-20mA + RS485
DRAIN (NOTE 1)
BLACK: + SUPPLY
WHITE: OUTPUT/GROUND
BLUE: RS485A
YELLOW: RS485B
DRAIN (NOTE 1)
BLACK: GROUND
WHITE: SDI-12
RED: + VCC
BLUE: RS485A
YELLOW: RS485B
ACCULEVEL SDI w/ATTACHED CABLE...SDI-12+ RS485
A-8
Keller America Inc User’s Guide Rev. 07/19 Keller America Inc User’s Guide Rev. 07/19
A-11
Signal cable
Transmitter
Vent tube
Bellows Assembly
Drying Tube Assembly
VENT TUBE TERMINATION - DRYING TUBE OR BELLOWS
Remove yellowcap after installation
NOTES: 1: FOR TRANSMITTERS WITH LIGHTNING/SURGE PROTECTION, CONNECT DRAIN WIRE TO A LOW-IMPEDANCE EARTH GROUND. FOR TRANSMITTERS WITHOUT LIGHTNING/SURGE PROTECTION, THIS PIN IS CONNECTED TO THE TRANSMITTER CASE. 2: DRYING TUBE ASSEMBLY - CLEAR TUBE FILLED WITH INDICATING DESICCANT, ATTACHES DIRECTLY TO CABLE VENT TUBE, INTERCEPTS WATER VAPOR. HIGHLY RECOMMENDED WHEN OPERATING IS IN HIGH HUMIDITY CONDITIONS. MUST BE PERIODICALLY RENEWED AS DESICCANT BECOMES SATURATED, TURNING COLOR FROM BLUE (DRY) TO PINK (SATURATED). REMOVE YELLOW CAP FROM FREE END AFTER INSTALLATION. 3: BELLOWS ASSEMBLY - ALTERNATIVE TO THE DRYING TUBE, THIS ANEROID BELLOWS ATTACHES TO CABLE VENT TUBE AND REQUIRES NO PERIODIC MAINTENANCE. RECOMMENDED WHERE A SLIGHT SACRIFICE IN ACCURACY CAN BE TOLERATED.
A-10
Electronic copies of this user’s guide can be found at: http://www.kelleramerica.com/manuals-and-software/manuals/Keller_America_Users_Guide.pdf
BORN SWISS · MADE AMERICAN · KELLERAMERICA.COM