47
FACULTY OF ENGINEERING TANTA UNIVERSITY DAMS & RESERVOIRS ENGINEERING 4 TH YEAR CIVIL/STRUCTURE 2012-2013 LECTURE 5 GRAVITY DAMS SAFETY & STABILITY ANALYSIS Instructor: Dr. Bakenaz A. Zedan
Transcript

FACULTY OF ENGINEERING TANTA UNIVERSITY

DAMS & RESERVOIRS ENGINEERING

4TH YEAR CIVIL/STRUCTURE 2012-2013

LECTURE 5GRAVITY DAMS

SAFETY & STABILITY ANALYSIS

Instructor:

Dr. Bakenaz A. Zedan

GRAVITY DAMS LECTURES TOPICS

1. CLASSIFICATION & COMPONENTS

2. PLANNING & STRUCTURAL DESIGN

3. SEISMIC FORCES & CASES OF LOADING

4. SAFETY & STABILITY ANALYSIS

5. STRESS ANALYSIS & DESIGN CRITERIA

6. CONSTRUCTION & FOUNDATION TREATMENT

2

4/2/2013

DR. BAKENAZ ZEDAN

GRAVITY DAMS LECTURES TOPICS

1. CLASSIFICATION & COMPONENTS

2. PLANNING & STRUCTURAL DESIGN

3. SEISMIC FORCES & CASES OF LOADING

4. SAFETY & STABILITY ANALYSIS

5. STRESS ANALYSIS & DESIGN CRITERIA

6. CONSTRUCTION & FOUNDATION TREATMENT

3

4/2/2013

DR. BAKENAZ ZEDAN

LECTURE 5 OUTLINE: Summary Of Cases Of Loading

Design Of Concrete Gravity Dams

Safety Of Concrete Gravity Dams

Stability Analysis

4

1. Stability Against Forward Overturning

Stability Against Forward Sliding

Stability Against Sliding & Shear

Stability Against Concrete Overstresses

Stability Against Foundation Overstresses

2.

3.

4.

5.

Solved Example

4/2/2013

DR. BAKENAZ ZEDAN

DR.BAKENAZZEDAN 4/2/2013

SUMMING UP CASES OF LOADINGCase 1: Reservoir is Empty - Just After Construction

Case 2: Reservoir is Full - Normal Operating

Conditions Case 3: Reservoir is Full - Flood Discharge

Conditions Case 4: Reservoir is Empty + Seismic

Forces

Case 5: Normal Operating Conditions + Seismic Forces

Case 6: Flood Discharge Conditions + Seismic Forces

Case 7: Normal Operating Conditions + Seismic Forces

+ Extreme Uplift

Case 8: Flood Discharge Conditions + Seismic Forces+ Extreme Uplift

6

4/2/2013DR. BAKENAZ ZEDAN

CASE 1 : RESERVOIR IS EMPTY

(JUST AFTER CONSTRUCTION)

DR. BAKENAZ ZEDAN4/2/2013

WWeight of the dam

7

hd

U

U= γw

h

γw

hd

P= γw

Pd

Ws

Ps

CASE 2 : RESERVOIR IS FULL

NORMAL OPERATING CONDITIONS

Hydrostatic pressure

N.U.W.L.

Ww

4/2/2013DR. BAKENAZ ZEDAN

hP

Wwd

W

N.D.W.L.

8

CASE 3 : RESERVOIR IS FULLFLOOD DISCHARGE CONDITIONS

4/2/2013DR. BAKENAZ ZEDAN

h'

h’d

U’

U’= γw

h’

γw

h’dP’= γw

h’δ

W’w

P’ W’wd

F.D.W.L

P’d

Ws

W

Ps

Hydrostatic pressure

F.U.W.L.

9

CASE 4 = RESERVOIR IS EMPTY + SEISMIC FORCES

4/2/2013DR. BAKENAZ ZEDAN

W

V H

Horizontal inertia forces due to earthquake accelerations

Vertical inertia forces due to earthquake accelerations

Weight of the dam

10

CASE 5 = NORMAL OPERATING CONDITIONS + EARTHQUAKE FORCES

4/2/2013DR. BAKENAZ ZEDAN

h

hd

UU= γw

h

γw

hd

P= γw

h δ

Ww

P Wwd

Pd

Ws

WV

Ps

Phyd H

P=Cs .γw .α.h

Vertical inertia forces due to earthquake accelerations

Horizontal inertia forces due to earthquake accelerations

Hydrodynamic pressure

Hydrostatic pressure N.U.W.L.

11

CASE 6 = FLOOD DISCHARGE CONDITIONS + EARTHQUAKE FORCES

4/2/2013DR. BAKENAZ ZEDAN

h'

H’d

γw

h’d

P’= γw

h’ δ

W’w

P’ W’wd

P’d

Ws

WV

Ps

P’hyd H

Hydrodynamic pressure

Hydrostatic pressure F.U.W.L.

Vertical inertia forces due to earthquake accelerations

Horizontal inertia forces due to earthquake accelerations

P’=Cs .γw .α.h’ U’= γw

h’U’ 12

CASE 7 = NORMAL OPERATING CONDITIONS + EARTHQUAKE FORCES + EXTREME UPLIFT

4/2/2013DR. BAKENAZ ZEDAN

13

h

hd

UU= γw

h

γw

hd

P= γw

h

Ww

P Wwd

Pd

Ws

WV

Ps

Phyd H

P=Cs .γw .α.h

Hydrodynamic pressure

Hydrostatic pressure N.U.W.L.

Vertical inertia forces due to earthquake accelerations

Horizontal inertia forces due to earthquake accelerations

CASE 8 = FLOOD DISCHARGE CONDITIONS + EARTHQUAKE FORCES+ EXTREME UPLIFT

4/2/2013DR. BAKENAZ ZEDAN

h'

H’d

U’

U’= γw

h’

γw

h’d

P’= γw

h’

P’=Cs .γw .α.h’

W’w

P’ W’wd

P’d

Ws

WV

Ps

P’hyd H

Hydrodynamic pressure

Hydrostatic pressure F.U.W.L.

Vertical inertia forces due to earthquake accelerations

Horizontal inertia forces due to earthquake accelerations

14

DESIGN OF GRAVITY DAMS

15

DR. BAKENAZ ZEDAN4/2/2013

INTRODUCTION: Dams are national properties, for the

development of national economy in which large investments are deployed

Safety of dams is a very important aspect for safeguarding national investment and benefits derived by the project

Unsafe dams constitute hazards to human life in the downstream reaches

Safety of dams and allied structures is an important aspect to be examined to ensure public confidence and to protect downstream area from any potential hazards.

DESIGN OF GRAVITY DAMS

Technically, a concrete gravity dam derives its

stability from the force of gravity of its materials.

The gravity dam has sufficient weight so as to withstand the force and the over turning moments caused by the water impounded in the reservoir behind it.

It transfers the loads to the foundations by cantilever action and hence good foundations are pre requisite for the gravity dam.

16

4/2/2013DR. BAKENAZ ZEDAN

DESIGN OF GRAVITY DAMS

17

Gravity dams are satisfactorily adopted for narrow valleys havingstiff geological formations.Their own weight resists the forces exerted upon them.They must have sufficient weight against overturning tendency about the toe.The base width of gravity dams must be large enough toprevent sliding.These types of dams are susceptible to settlement, overturning, sliding and severe earthquake shocks.

4/2/2013DR. BAKENAZ ZEDAN

PROCEDURE OF CONCRETE GRAVITY DESIGN

18

In the gravity dam calculations one should proceed through the following steps:1determination of all expected acting loads2 state the combination of acting loads for each case of loading3check stability against overturning for all possible cases of loading (cases of full reservoir)4 check stability against forward sliding for all possible cases of

loading (casesof full reservoir)5determine normal stress distribution at dam base and any given sections for all cases of loading6determine maximum and minimum principal and shear stresses at dam base and any given sections for all cases of loading7compare results with corresponding factors of safety and allowable stresses 8- approve the dam profile or redesign for a new profile

4/2/2013DR. BAKENAZ ZEDAN

STABILITY CRITERIA

19

Stability analyses are performedfor various loading conditionsThe structure must prove its safety

and stabilityunder all loading conditions.Since the probability of occurrence of extreme events is relatively small, the joint probability of the independent extreme events is negligible. In other words, the probability that two extreme events occur at the same time is relatively very low.Therefore, combination of extremeevents are not considered in the stability criteria.e.g. Floods (spring and summer) versus Ice load (winter). then no need to consider

these two forces at thesame time.

DR. BAKENAZ ZEDAN4/2/2013

STABILITY CRITERIAUsual LoadingHydrostatic force (normal operating level) Uplift forceTemperature stress (normal temperature)Dead loads Ice loads Silt loadUnusual Loading Hydrostatic force (reservoir full) Uplift forceStress produced by minimum temperature at full level Dead loadsSilt loadExtreme (severe) LoadingForces in Usual Loading and earthquake forces

DR. BAKENAZ ZEDAN4/2/2013

20

STABILITY CRITERIA

21

The ability of a dam to resist the applied loads is measured by some safety factors.To offset the uncertainties in the loads, safety criteria are chosen sufficiently beyond the static equilibrium condition.Recommended safety factors: (USBR, 1976 and1987)However, since each dam site has unique features, different safety Factors may be derived considering the local condition.

DR. BAKENAZ ZEDAN4/2/2013

STABILITY CRITERIA

F.S0: Safety factor against

overturning. F.Ss: Safety factor

against sliding.

F.Sss: Safety factor against shear and

sliding.

4/2/2013DR. BAKENAZ ZEDAN

22

STABILITY ANALYSIS OF GRAVITY DAMS

23

1 Stability against overturning

2 Stability against Forward sliding

3 Failure against overstressingNormal stresses on horizontal planes Shear stresses on horizontal planesNormal stresses on vertical planesPrincipal stressesPermissible stresses in concrete

DR. BAKENAZ ZEDAN4/2/2013

STABILITY ANALYSIS OF CONCRETE GRAVITY DAMS

For the considerations of stability of a concrete gravity dam the following assumptions are made:

4/2/2013

DR. BAKENAZ ZEDAN

thedam

• Is composed of individual transversevertical elements each of which carries its load to the foundation separately

Stability analysis

• Is carried out for the whole block

vertical stress

• Varies linearly from upstream face to downstream face on any horizontal section

24

CLASSIFICATION OF LOADING FOR DESIGN

Normal LoadsThey are those, under the combined action of which the dam shall have adequatestability, and the factors of safety and permissible stresses in the dam shall not be exceeded.

25

4/2/2013

DR. BAKENAZ ZEDAN

Abnormal LoadsThese are the loads which in combination with normal loads encroach upon the factor of safety and increase the allowable stresses although remaining lower than the higher emergency stress limits.

Normal Loads Abnormal Loads

Water pressure corresponding to full reservoir level.

Higher water pressure during floods

Weight of dam and structure above it.

Earthquake force

Uplift. Silt pressure

Wave pressure

Ice thrust

Thermal stresses

ACTING STATIC FORCES

4/2/2013

DR. BAKENAZ ZEDAN

1.Weight of the dam2.Thrust

ofthe tail water

Forcesthat give stability

1.Reservoir water

pressure2.Uplift3. Ice pressure4.Temperaturestresses6. Silt pressure

StaticForces

that try to destabilize

26

ACTING DYNAMIC FORCES

4/2/2013

DR. BAKENAZ ZEDAN

1.Weight of the dam2.Thrust

ofthe tail water

Forcesthat give stability

1.Seismic forces

2.Hydrodynamic pressure3.Forces due to waves in the reservoir4.Wind

pressure

Dynamic

Forcesthat try todestabilize

27

SAFETY OF CONCRETE GRAVITY DAM

Equilibrium states that:∑FX=0, ∑FY=0,∑M@ any

point=0 Should attained otherwiseIf ∑FX ≠ 0, forward sliding may occurIf ∑FY ≠ 0, settlement may occurIf ∑M ≠ 0 forward overturning may occur

If eccentricity exceeds B/6 , tension forcesmay occur If working

stresses greater than allowable stressesfailure may occur due to excessive stresses or crushing.

28

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY OF CONCRETE GRAVITY DAM

Thus a dam profile should be safe against:

29

1.

forward sliding and translationSettlement or tiltingforward overturning or rotationTensile stressesfailure due to over stresses Cracks & material failureHigher responses than allowable limit

according to codes

2.3.4.5.6.7.

4/2/2013

DR. BAKENAZ ZEDAN

STRUCTURAL STABILITY ANALYSIS

The stability analysis of a dam sectionunder

static and dynamic loads is carried out to check the safety with regards to:

30

1.

Rotation and overturning Translation and sliding Overstress and material failure

2.3.

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST OVERTURNING

31

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST OVERTURNING

4/2/2013

DR. BAKENAZ ZEDAN

B

Mr

Mo

Heel toe

32

SAFETY AGAINST FORWARD SLIDING

33

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST FORWARD SLIDING

4/2/2013

DR. BAKENAZ ZEDAN

34

SAFETY AGAINST FORWARD SLIDING

35

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST FORWARD SLIDING

In the presence of a horizon with low shear resistance the net shear force may equal to:

(W cosα+ ∑Hsin α) tanφ

where W is the passive resistance wedge,α is the assumed angle of sliding failure,∑H is the net de-stabilizing horizontal moment,and φ is the internal friction within the rock at plane B-B

DR. BAKENAZ ZEDAN4/2/2013

36

SAFETY AGAINST FORWARD SLIDING

4/2/2013

DR. BAKENAZ ZEDAN

Heel toeDam bse

37

THE FACTOR OF SAFETY AGAINST SLIDING AND SHEAR:

38

DR. BAKENAZ ZEDAN4/2/2013

SAFETY AGAINST OVERSTRESSING

A dam may fail if any of its part is overstressed and hence the stresses at any part of the dam should not exceed the allowable working stress of concrete.

Hence the strength in dam concrete should be more than the anticipated in the structure by a safe margin

The maximum compressive stresses occur at:

at heel (at reservoir empty condition)or at toe (at reservoir full condition)and on planes normal to the face of the dam.

39

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST OVERSTRESSING

For design considerations, the calculation of the stresses in the body of the dam follows from the basics of elastic theory, which is applied in two- dimensional vertical plane, and assuming the block of the dam to be a cantilever in the vertical plane attached to the foundation.The contact stress between the foundation and the dam or the internal stress in the dam body must be compressive.

40

4/2/2013

DR. BAKENAZ ZEDAN

SAFETY AGAINST CONCRETE OVERSTRESSING

DR. BAKENAZ ZEDAN4/2/2013

Normal stress Bending or flexural stresσheel

s

σtoe

Base pressure distribution

∑V

B

41

NORMAL STRESSES AT DAM BASE

Normal stress:

4/2/2013

DR. BAKENAZ ZEDAN

c.g.

xMy

σnheel σntoe

1m +

∑V

y∑H

BHeel toe

e

42

SAFETY AGAINST FOUNDATIONOVERSTRESSING

AT DAM BASENaturally, there would be tension on the upstream face if the overturning moments under the reservoir full condition increase such that e becomes greater than B/6. The total vertical stresses at the upstream and downstream faces are obtained by addition of external hydrostatic pressures.The contact stress between the foundation and the dam or the internal stress in the dam body must be compressive. In order to maintain compressive stresses in the dam or at the foundation level, the minimum pressure σmin ≥ 0. This can be achieved with a certainrange of eccentricity.

DR. BAKENAZ ZEDAN4/2/2013

43

SAFETY AGAINST OVERSTRESSING

DR. BAKENAZ ZEDAN4/2/2013

e

σheel

σtoe

Base pressure distributionFo

r a

un

it

wid

th

44

DR. BAKENAZ ZEDAN

STABILITY CRITERIAThe contact stress between the foundation and the dam or the

internal stress in the dam body must be compressive:Tension along the upstream face of a gravity dam is possible

under reservoir operating conditions.

4/2/2013

z = 1.0 (if there is no drainage in the dam body)z = 0.4 (if drains are used)P: hydrostatic pressure at the level under consideration

45

DR.BAKENAZZEDAN

46

4/2/2013

Given data:

Crest width 1 0 m

Base width 50m

Height of dam 60m

Height of reservoir

55m Tail water height 0

m

Height of sedimentation 10m

Unit weight of concrete =24

KN/m3 Modulus of Elasticity= 28

MPa

Unit weight of water= 1 0 KN/m3

Unit weight of sedimentation =14

KN/m3 Seismic coefficient= 0.2

Required:

Check the stability of the dam profile

( q> = 30°)

QUESTIONS

47

4/2/2013

DR. BAKENAZ ZEDAN