175-000033-00 Edition C Installation and Operation Manual Multi-Channel Remote Synchronizer Control RC-575
Transcript
Page 1: Leirch RC-575_Synchro Controller

175-000033-00Edition C

Installation and Operation Manual

Multi-ChannelRemote Synchronizer Control

RC-575

Page 2: Leirch RC-575_Synchro Controller

ADAC,ADCOE, BOS, Broadcast Operating system, CCS, DigiBus, DigiPeek,Digital Glue, DigiWorks, DTV Glue, Engineering The Big Picture,EventWORKS, EZ HD, Focused on the Future, Genesis, HDTV Glue, HEDCO,Innovision, ISIS, JUNO, LeFont, Leitch, Leitch Network Systems, LNS,LogoMAX, LogoMotion, MediaFile, MediaPort, MIX BOX, Monarch, MotionFile, OPUS, PanelMAPPER, Pilot, Portal, PROM-Slide, RouterWORKS,StillFile, Still Net, Tekniche, Unilock,VIA,ViewGuard,Whiplash2, Xplus, andLeitch XPRESS are trademarks and/or registered trademarks of LeitchTechnology Corporation in the United States, Canada, and/or other countries.

All other trademarks are the property of their respective owners.

Copyright 2002, Leitch Incorporated.All rights reserved. This publicationsupersedes all previous releases. Printed in Canada.

Trademarks and Copyright

Page 3: Leirch RC-575_Synchro Controller

RC-575.book Page i Thursday, May 9, 2002 2:15 PM

RC-575 Multi-Channel Remote Synchronizer Control

Installation and Operation Manual

Edition C

April 2002

Page 4: Leirch RC-575_Synchro Controller

RC-575.book Page ii Thursday, May 9, 2002 2:15 PM

Page 5: Leirch RC-575_Synchro Controller

RC-575.book Page iii Thursday, May 9, 2002 2:15 PM

Preface

Purpose

This manual details the features, installation procedures, operational procedures, and specifications of the RC-575 Multi-Channel Remote Synchronizer Control.

Audience

This manual is written for technicians and operators responsible for installation, setup, and/or operation of RC-575 Multi-Channel Remote Synchronizer Control.

Writing Conventions

To enhance your understanding, the authors of this manual have adhered to the following text conventions:

Bold Indicates dialog box, property sheet, field, button, checkbox, listbox, combo box, menu, submenu, window, list, and selection names.

Italics Indicates email addresses, names of books and publications, and first instances of new terms and specialized words that need emphasis.

CAPS Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, DELETE.

Code Indicates variables or command-line entries, for example, a DOS entry, something you type into a field, etc.

> Indicates direction of navigation through a hierarchy of menus and windows.

hyperlink Indicates a jump to another location in the document or elsewhere (such as a website).

RC-575 Installation and Operation Manual iii

Page 6: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page iv Thursday, May 9, 2002 2:15 PM

Revision History

Edition Date Revision History

A October 2000 Initial release.

B January 2001 Formatting changes.

C April 2002 Formatting changes.

iv RC-575 Installation and Operation Manual

Page 7: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page v Thursday, May 9, 2002 2:15 PM

Important Safety InstructionsReview the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions.

Servicing

Only qualified personnel should perform service procedures. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Safety Terms and Symbols

Terms and Symbols in This Manual

Terms and Symbols on the Product

WARNING: Statements identifying conditions or practices that can result in personal injury or loss of life: High voltage is present. Uninsulated dangerous voltage within the product’s enclosure may be sufficient to constitute a risk of electric shock to persons.

CAUTION:Statements identifying conditions or practices that can result in damage to the equipment or other property: Important operating and maintenance (servicing) instructions in the literature accompanying the product.

DANGER: High voltage and indicates a personal injury hazard immediately accessible as one reads the marking.

WARNING: Indicates a personal injury hazard not immediately accessible as one reads the marking.

CAUTION: Indicates a hazard to property including the product or to take attention and refer to the manual.

RC-575 Installation and Operation Manual v

Page 8: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page vi Thursday, May 9, 2002 2:15 PM

Injury Precautions

Protective ground (earth) terminal.

Fuse: Replace with same type and rating of fuse.

Observe precautions for handling electrostatic-sensitive devices.

WARNING!To reduce the risk of electric shock, do not expose this apparatus to rain or moisture.

WARNING! Potentially lethal voltages are present within this product’s frame during normal operation. The AC power cord must be disconnected from the frame before the top panel is removed. (In frames with multiple power supplies, remove ALL power cords.) Power should not be applied to the frame while the top is open, unless properly trained personnel are servicing the unit.[PL Poland] Przod zdjeciem pokrywy wyciagnac wtyczke z gniazda sieciowego.[French] AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. INSTALLER SUR SUPPORT DE MONTAGE SEULEMENT.

RISK OF ELECTRIC SHOCKDO NOT OPEN

CAUTION

vi RC-575 Installation and Operation Manual

Page 9: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page vii Thursday, May 9, 2002 2:15 PM

AVIS - Risque de choc electrique. Ne pas ouvrir.

RC-575 Installation and Operation Manual vii

Page 10: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page viii Thursday, May 9, 2002 2:15 PM

Use Proper Power CordTo avoid fire hazard, use only the power cord specified for this product.

Ground the ProductDo not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.[United Kingdom] WARNING: THIS APPLIANCE MUST BE EARTHED.[Sweden] APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG NÄR DEN ANSLUTS TILL ETT NÄTVERK.

Do Not Operate Without CoversTo avoid electrical shock or fire hazard, do not operate this product with covers or panels removed.

Use Proper FuseTo avoid fire hazard, use only the fuse type and rating specified for this product.

Do Not Operate in Wet/Damp ConditionsTo reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture

Do Not Operate in an Explosive AtmosphereTo avoid injury or fire hazard, do not operate this product in an explosive atmosphere.

Avoid Exposed CircuitryTo avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do not touch exposed connections and components when power is present.

viii RC-575 Installation and Operation Manual

Page 11: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page ix Thursday, May 9, 2002 2:15 PM

Product Damage Precautions

Use Proper Power SourceDo not operate this product from a power source that supplies more than the specified voltage.

Use Proper Voltage SettingBefore applying power, ensure that the line selector is in the proper position for the power source being used.

Provide Proper VentilationTo prevent product overheating, provide proper ventilation.

Do Not Block Any Ventilation OpeningsDo not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.

Only Use Attachments/Accessories Specified by the Manufacturer

Do Not Operate With Suspected FailuresRefer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.For Products with Multiple Power Cords:CAUTION: This unit can have more than one power supply cord. To de-energize the internal circuitry, disconnect all power cords before servicing.[Norwegian] ADVARSEL: Utstyret kan ha mere ennn en tilførselsledning. For å gjore interne deler spennigsløse må alle tilførselsledningene trekkes ut.[Sweden] VARNING: Denna apparat har mer än en nätanslutning. Samtliga nätkablar måste bortkopplas för att göra de interna kretsarna spänningsfria.

Do not use this apparatus near waterDo not expose this apparatus to dripping or splashing water. Ensure that no objects filled with liquid, such as vases or cups, are placed on the apparatus.

RC-575 Installation and Operation Manual ix

Page 12: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page x Thursday, May 9, 2002 2:15 PM

Clean only with a dry cloth

Keep Product Away from Heat SourcesDo not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

Install Near Socket OutletThe equipment shall be installed near the socket outlet, and a disconnect device shall be easily accessible.

Protect the Power CordProtect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

Attention:Observe precautions for handling electrostatic-sensitive devices.See “Preventing Electrostatic Discharge” below for details.

Fuse Replacement:CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH THE SAME TYPE OF FUSE.[French]ATTENTION: REMPLACER UNIQUEMENT PAR UN FUSIBLE DE MEME TYPE.

List of replaceable fuses Marking

F1 main primary (P.S.) T2 Amp/250 V

x RC-575 Installation and Operation Manual

Page 13: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page xi Thursday, May 9, 2002 2:15 PM

Battery Use Warnings

CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY PLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.[FI Finland] VAROITUS: Paristo voi rajahtaa, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan valmistajan suosittelemaan tyyppun. Havita kaytetty paristo valmistajan ohjeiden mukaisesti.[SE Sweden] VARNING: Explosionsfara vid felaktigt batteribyte. Anvand samma batterityp eller en eller en ekvivalent typ som rekommenderas av tillverkaren. Kassera anvant batteri enligt fabrikantens instruktion. [D Denmark]

[KO Korean]

Advarsel! Lithiumbatteri. Eksplosionsfare ved fejlagtig handtering. Udskiftning ma kun ske med batteri af samme fabrikat oq type. Lever det brugte batteri tilbage till leverandoren.

RC-575 Installation and Operation Manual xi

Page 14: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page xii Thursday, May 9, 2002 2:15 PM

Preventing Electrostatic Discharge

.

CAUTION: Electrostatic discharge (ESD) can damage components in the product. To prevent ESD, observe these precautions when directed to do so:Use a Ground Strap. Wear a grounded antistatic wrist strap to discharge the static voltage from your body while installing or removing sensitive components.Use a Safe Work Area. Do not use any devices capable of generating or holding a static charge in the work area where you install or remove sensitive components. Avoid handling sensitive components in areas that have a floor or benchtop surface capable of generating a static charge.Handle Components Carefully. Do not slide sensitive components over any surface. Do not touch exposed connector pins. Handle sensitive components as little as possible.Transport and Store Carefully. Transport and store sensitive components in a static-protected bag or container.

xii RC-575 Installation and Operation Manual

Page 15: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page xiii Thursday, May 9, 2002 2:15 PM

Certifications and CompliancesThis product has been tested and found to comply with the following CE, FCC, UL, ICES and CSA standards.

EMC Standards

Standard Description

EN 55103-1:1997 Emissions, Conducted and Radiated, per EN 55022 Class A; Peak Inrush Current - Product Family Standard - Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use.Peak Inrush Current is 21.7A max

EN 55103-2:1997 Immunity, Electromagnetic environment E4 -controlled EMC Environment - Product Family Standard - Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use.

EN 61000-4-2 Electrostatic Discharge4kV contact discharge (direct & indirect)8kV air discharge

EN 61000-4-3 Radiated RF Immunity3Vrms/m, 80-1000 MHz, 1kHz 80% AM Modulation

EN 61000-4-4 Electrical Fast Transient +/- 1kV on AC Lines +/- 0.5 kV on I/O Lines

EN 61000-4-5 Surge Withstand Immunity+/- 1kV Common Mode on AC Lines+/- 0.5 kV Differential Mode on I/O Lines

EN 61000-4-6 Conducted RF Immunity3Vrms/m, 0.15-80 MHz, 150 ohms, 1 kHz 80%AM Modulation on AC & I/O Lines

EN 61000-4-8 Magnetic Field Immunity 50 Hz, 3 A/m

EN 61000-4-11 Dipp100% - 20ms Dip 60% - 100msDropouts >95% for 5 sec, 5 times at 10 sec interval

EN 61000-3-2 Harmonic Current Emissions Class A (Other)

EN 61000-3-3 Voltage Fluctuation and Flicker in Low-Voltage Supply Systems

RC-575 Installation and Operation Manual xiii

Page 16: Leirch RC-575_Synchro Controller

Preface

RC-575.book Page xiv Thursday, May 9, 2002 2:15 PM

Per the provision of the Electromagnetic Compatibility Directive 89/336/EEC of 3 May 1989 as amended by 92/31EEC of 28 April 1992 and 93/68/EEC, Article 5 of 22 July 1993.

These devices are for professional use only and comply with Part 15 of FCC rules. Operation is subject to the following two conditions:

1. These devices may cause interference to Radio and TV receivers in residential areas.

2. These devices will accept any interference received, including interference that may cause undesired operations. This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Changes or modifications not expressly approved by Leitch, the party responsible for compliance to the FCC Part 15 Rule, could void the user’s authority to operate this equipment legally in the US.

Safety Standards

Standard Description

EN 60950 Safety of information technology equipment, including electrical business equipment (IEC 60950 (1999)), per the provision of the Low-Voltage Directive 73/23/EEC of February 19, 1973 as amended by 93/68/EEC.

CSA C22.2 No. 1 Safety standard for Audio/Video and similar electronic equipment.

UL 1419 Safety requirements for professional audio video equipment.

xiv RC-575 Installation and Operation Manual

Page 17: Leirch RC-575_Synchro Controller

RC-575.book Page xv Thursday, May 9, 2002 2:15 PM

Contents

Chapter 1: Installation.....................................................1Unpacking and Inspection .........................................................................1

Mounting ............................................................................................. 1

Connections ................................................................................................ 2

Ethernet Port ....................................................................................... 2

DCN Ports ........................................................................................... 2

RS-232/RS-422 Port ............................................................................ 3

422 Term Switch .................................................................................. 3

Chapter 2: Front Panel Controls.....................................5Overview ..................................................................................................... 5

VFD Display ............................................................................................... 6

Remote Control .......................................................................................... 7

Menu Controls ............................................................................................8

Moving Through the Menus ............................................................... 8

Changing Parameters .......................................................................... 8

Chapter 3: Menu Options..............................................11Overview ................................................................................................... 11

Miscellaneous Setup ................................................................................. 12

Remote Control Setup .............................................................................. 13

Baud Rate ........................................................................................... 13

Remote Control ................................................................................. 13

IP Address ......................................................................................... 14

Netmask ............................................................................................. 14

Gateway ............................................................................................. 15

Machine Name ................................................................................. 16

DCN Address .................................................................................... 16

RC-575 Installation and Operation Manual xv

Page 18: Leirch RC-575_Synchro Controller

RC-575.book Page xvi Thursday, May 9, 2002 2:15 PM

Version Information ................................................................................. 17

Flash Memory Management .................................................................... 18

List Files ............................................................................................. 18

Backup All Settings ............................................................................ 18

Restore All Settings ........................................................................... 19

Warm Reset .............................................................................................. 20

Reset to Factory Defaults .................................................................. 20

Appendix A: The Uploader Software ..........................21Overview ................................................................................................... 21

Software Installation ................................................................................. 22

Download From Website .................................................................. 22

CD-Rom ............................................................................................ 22

Starting the Software ......................................................................... 22

Using the Software .................................................................................... 23

Uploading Files ................................................................................. 24

RC-575 Installation and Operation Manual xvi

Page 19: Leirch RC-575_Synchro Controller

RC-575.book Page 1 Thursday, May 9, 2002 2:15 PM

Chapter 1

Installation

Unpacking and InspectionThis unit has been thoroughly calibrated and inspected, both electronically and mechanically, to ensure that it meets the published specifications.

The following items are included with each unit:

MountingThe size of the RC-575 allows it to fit into most standard consoles or 19-inch racks. Care must be taken to select a dry, well-ventilated location with a minimum of dust vibration. Also, leave sufficient clearance from the rear of the unit to allow for proper air circulation.

After unpacking the unit and before installing it in a console or track, allow at least 30 minutes for temperatures to equalize and to eliminate any condensation may have developed.

Quantity Description

1 RC-575

1 Installation and Operation Manual

1 AC Power Cord (Part # 773-254 or 773-505)

RC-575 Installation and Operation Manual 1

Page 20: Leirch RC-575_Synchro Controller

Connections Chapter 1: Installation

RC-575.book Page 2 Thursday, May 9, 2002 2:15 PM

Connections

Ethernet Port

Figure 1-1. RC-575: Back Panel

The 10BaseT Ethernet connector, labeled Ethernet on the rear of the unit, is used to connect the RC-575 to a TCP/IP-based network, for remote control of up to w00 DPS-575 series synchronizers. When using Ethernet, the IP Address, Netmask, and Gateway settings of the unit must be configured for your network; your network administrator can provide you with these settings. These settings are located in the System Config menu, under the Remote Control Setup sub-menu (see Chapter 3, "Menu Options", on page 11).

The Link LED indicates network activity on the Ehernet port.

DCN PortsThe BNC connectors labeled DCN on the rear of the unit are used to connect the RC-575 via the DCN (Digital Coaxial Network) interface. DCN is a proprietary network in which 75 Ω coax is used as a multidrop, bi-directional network.

Using BNC T-Connectors, loop coaxial cable between each unit and the RC-575. At each end of the chain, install a 75 Ω terminator. The two DCN connectors on the RC-575 are passive loop-throughs, eliminating the need for the use of a BNC-T connector on the RC-575 itself. 75 Ω coax from a remote unit will be connected to one of the connectors, with either a 75Ω terminator or 75 Ω coax to another remote unit on the other.

Every unit is assigned a unique DCN address at the factory, so there is no software configuration required. The maximum cable length (total) in a DCN configuration should be limited to 2000 ft. (609.6 m). Up to 20 DPS-575 series synchronizers can be controlled via DCN.

ETHERNET

LINK

DCN

42 2 TERM

RS-23 2 / 422

Do not exceed 48 units on the same subnet.Do not exceed three Web browsers on the same subnet.

RC-575 Installation and Operation Manual 2

Page 21: Leirch RC-575_Synchro Controller

Connections Chapter 1: Installation

RC-575.book Page 3 Thursday, May 9, 2002 2:15 PM

RS-232/RS-422 PortThe DB-9F connector labeled RS-232/422 on the rear panel of the unit is used to connect the RC-575 to a Microsoft® Window®-based workstation for the uploading of firmware upgrades. See Chapter A, "Upgrading The Firmware", on page 21 for information on upgrading the firmware from a Microsoft® Windows® system.

422 Term SwitchFuture use function — the 422 Term switch enables or disables termination of the serial port. When the serial port is used as RS-232 (as opposed to RS-422), termination must be off.

RC-575 Installation and Operation Manual 3

Page 22: Leirch RC-575_Synchro Controller

Chapter 1: Installation Connections

RC-575.book Page 4 Thursday, May 9, 2002 2:15 PM

4 RC-575 Installation and Operation Manual

Page 23: Leirch RC-575_Synchro Controller

RC-575.book Page 5 Thursday, May 9, 2002 2:15 PM

Chapter 2

Front Panel Controls

Overview

Figure 2-1. RC-575: Front Panel Controls

The front panel controls of the RC-575 are identical to those of the DPS-575 series synchronizers.

Menu control information required for configuration of the RC-575 and selection of which remote unit to control is included in this section. Documentation of all other front-panel controls can be found in the DPS-575 Installation and Operation Manual that is included with your synchronizers.

Figure 2-2. RC-575 Menu Controls

The RC-575 controls the DPS-475 and DPS-575 series units.

RC-575 Installation and Operation Manual 5

Page 24: Leirch RC-575_Synchro Controller

Chapter 2: Front Panel Controls VFD Display

RC-575.book Page 6 Thursday, May 9, 2002 2:15 PM

VFD DisplayMenu options, selections, and feedback are shown on the Vacuum Fluorescent Display (VFD) display panel.

The display will “invert” itself at regular intervals. In the initial state, text and information appears lit, over an “unlit” background. In the inverted state, the background will be lit, with the text and information appearing “unlit” (black). This periodic inversion is normal; it does not indicate any kind of problem nor status. The inversion is done to preserve the lifespan of the display panel (leaving the display in a single state can cause display pixels to burn out prematurely).

6 RC-575 Installation and Operation Manual

Page 25: Leirch RC-575_Synchro Controller

Remote Control Chapter 2: Front Panel Controls

RC-575.book Page 7 Thursday, May 9, 2002 2:15 PM

Remote ControlPressing the Remote front-panel key (see Figure 2-2, page 5) will bring up a list of available units that can be controlled. "<local device>" will always be an option on this list, representing the RC-575 itself. Use the Control Knob to scroll through the list of available devices and highlight the unit you wish to control, then press the Enter button to activate it. Selecting <local device> exits Remote mode, and indicates that no synchronizer is being controlled, and that the menu controls can be used for configuration of the RC-575.

Once you have selected a remote unit to control, all front-panel features operate as if you were actually at the front panel of that remote unit. The VFD display, status indicators and LEDs all reflect the status of the remote unit; all buttons and controls, with the exception of the Remote key, control the remote unit and not the RC-575 itself. To stop controlling the remote unit, use the Remote key to select a new unit (or the RC-575 itself) to control.

The light on the Remote key flashes while the RC-575 is remotely controlling a device.

RC-575 Installation and Operation Manual 7

Page 26: Leirch RC-575_Synchro Controller

Chapter 2: Front Panel Controls Menu Controls

RC-575.book Page 8 Thursday, May 9, 2002 2:15 PM

Menu ControlsAll configuration parameters for the RC-575 are accessed through configuration menus, which appear on the display panel. Selecting and using any of the menu and sub-menu options follows the same general procedure.

Moving Through the Menus1. Ensure that the RC-575 is not in Remote mode. (The light on the

Remote key flashes if the unit is remotely controlling a device.)

If the RC-575 is in Remote mode, press the Remote key to enter the Unit Selection menu, select <local device> and then press Enter to return to local control.

2. Press the Enter button.

The display shows the Main Menu options.

3. Scroll through the list using the Control Knob until the desired sub-menu is highlighted, and then press the Enter button to enter the sub-menu.

4. Use the Control Knob and Enter button to choose and activate the option you want.

If there are further sub-menus, use the procedure in step 3 to select between them, and to select the option you wish to change.

5. Press the Exit to return you to the previous sub-menu, or if you are at the Main Menu, to exit the menus.

Changing ParametersOnce you have selected the option you wish to change, use the Control Knob to set the new value for the parameter. When setting parameters that have discrete value options (such as selecting 9600 or 38400 baud), the Control Knob cycles through the valid settings.

For parameters with a numerical range of values, the display shows both a numeric and a visual representation of the range, use the Control Knob to set the new value.

8 RC-575 Installation and Operation Manual

Page 27: Leirch RC-575_Synchro Controller

Menu Controls Chapter 2: Front Panel Controls

RC-575.book Page 9 Thursday, May 9, 2002 2:15 PM

When setting parameters with a numerical range of values, you can switch the Control Knob between Fine and Coarse Adjustment mode. When you first enter the parameter adjustment screen, the Control Knob is in Fine mode. Press the Enter button to switch to Coarse Adjustment mode; the Enter button lights up the Coarse Adjustment mode. This allows you to make large adjustments more quickly. Press Enter again to return the Control Knob to Fine mode.

Press the Default button to reset the configuration parameter to its default values. The Default button lights up whenever the current value of the parameter is equivalent to the default value (whether you reached this value by pressing the Default button, or scrolling to it with the Control Knob).

Press the Exit button to accept your new value, and return to the previous menu or sub-menu.

RC-575 Installation and Operation Manual 9

Page 28: Leirch RC-575_Synchro Controller

Chapter 2: Front Panel Controls Menu Controls

RC-575.book Page 10 Thursday, May 9, 2002 2:15 PM

10 RC-575 Installation and Operation Manual

Page 29: Leirch RC-575_Synchro Controller

RC-575.book Page 11 Thursday, May 9, 2002 2:15 PM

Chapter 3

Menu Options

OverviewSelecting the Remote menu is equivalent to pressing the Remote key on the front panel of the RC-575, and is used to select the remote unit to be controlled. See Chapter 2, "Front Panel Controls," on page 5 for details on selecting the remote unit.

The System Config menu is used for configuration of the RC-575. The following sections detail the options available in this menu.

RC-575 Installation and Operation Manual 11

Page 30: Leirch RC-575_Synchro Controller

Chapter 3: Menu Options Miscellaneous Setup

RC-575.book Page 12 Thursday, May 9, 2002 2:15 PM

Miscellaneous Setup

VFD Brightness

LED Brightness

Description Adjust the brightness level of the Vacuum Fluorescent Display (VFD) panel on the front of the RC-575.

Valid Range 1 to 15

Default Setting 7

Description Adjust the brightness level of indicator LEDs on the front of the RC-575.

Valid Range 0 to 15

Default Setting 7

The higher values shorten the life span of the the display panel.

12 RC-575 Installation and Operation Manual

Page 31: Leirch RC-575_Synchro Controller

Remote Control Setup Chapter 3: Menu Options

RC-575.book Page 13 Thursday, May 9, 2002 2:15 PM

Remote Control Setup

Baud Rate

Remote Control

Description Specifies the data rate for serial remote control. This setting must match that of the unit being controlled. (Future Use)

Valid Range Valid Settings: 9600 bps, 38400 bps

Default Setting 9600 bps

Description Specifies the protocol used for serial remote control. This setting must match the protocol of the unit being controlled. (Future Use)

Valid Range RS-232, RS-422

Default Setting RS-232

RC-575 Installation and Operation Manual 13

Page 32: Leirch RC-575_Synchro Controller

Chapter 3: Menu Options Remote Control Setup

RC-575.book Page 14 Thursday, May 9, 2002 2:15 PM

IP Address

The IP address must be set to be consistent with your existing TCP/IP network and the remote units to be controlled. Your network administrator can provide you with an appropriate IP address to use.

IP addresses are represented as four numbers (each from 0 to 255), separated by periods (for example, 10.0.0.1).

The IP Address option is set by using the Enter key and Control Knob. Press the Enter keyto cycle through the four numeric components of the IP address you need to modify; the Control Knob sets the value of that numeric component, from 1 to 254. Press the Exit key to store the IP address.

Netmask

The subnet mask must be set to be consistent with your existing TCP/IP network and the remote units to be controlled. Your network administrator can provide you with an appropriate subnet mask to use.

Subnet mask settings are often represented as hexidecimal digits. (for example 0xFFFF0000). Translation of this notation is straightforward, as each pair of hexidecimal digits is converted to its decimal equivalent(FF = 255, F0 = 240, etc.). Thus, the above example is equal to 255.255.0.0; 0xFFFFF000 is equal to 255.255.240.0.

Description Specifies the IP address of the RC-575 on a TCP/IP network. The IP address is used when the RC-575 is used to control units via the 10BaseT Ethernet port.

Default Setting 10.0.XX.YY where XXYY is the unit serial number

Related Settings Netmask, Gateway

Description Specifies the subnet mask of the RC-575 on a TCP/IP network. The subnet mask is used when the RC-575 is used to control units via the 10BaseT Ethernet port, and is represented as four numbers separated by periods (for example, 255.240.0.0).

Valid Range 128.0.0.0 to 255.255.255.240

Default Setting 255.255.0.0

Related Settings IP Address, Gateway

14 RC-575 Installation and Operation Manual

Page 33: Leirch RC-575_Synchro Controller

Remote Control Setup Chapter 3: Menu Options

RC-575.book Page 15 Thursday, May 9, 2002 2:15 PM

Gateway

The gateway address must be set to be consistent with your existing TCP/IP network and the remote units to be controlled. Your network administrator can provide you with the gateway IP address to use.

Gateway IP addresses are represented as four numbers (each from 0 to 255), separated by periods (for example, 10.0.0.1).

Use a gateway IP address of 0.0.0.0 to disable the use of the gateway.

The Gateway option is set by using the Enter key and Control Knob. Press the Enter key to cycle through the four numeric components of the gateway IP address you need to modify; the Control Knob sets the value of that numeric component, from 0 to 255. Press the Exit key to store the gateway IP address.

Description Specifies the IP address of the network gateway for the RC-575 on a TCP/IP network. The gateway address is used when the RC-575 is used to control units via the 10BaseT Ethernet port.

Valid Range 128.0.0.0 to 255.255.255.240

Default Setting 0.0.0.0

Related Settings IP Address, Netmask

RC-575 Installation and Operation Manual 15

Page 34: Leirch RC-575_Synchro Controller

Chapter 3: Menu Options Remote Control Setup

RC-575.book Page 16 Thursday, May 9, 2002 2:15 PM

Machine Name

The name can be up to 23 characters long, and is set by using the Enter key and Control Knob.

Press the Enter key to cycle through the character position; (1 to 23) the Control Knob selects a new character for that position.

There are two rules to keep in mind when specifying a name:

• Two consecutive spaces are not allowed;

• Attempting to move to the next character position after a space will return to the first character position.

Press the Exit key to store the new Machine Name.

DCN AddressReports the address at which the RC-575 is found on a DCN network (Digital Coaxial Network). This address is set at the factory, and cannot be changed by the operator.

Description Specifies a name for the RC-575. This name appears on other remote controllers and networks and identifies the machine. This allows the unit to be visually recognized on a remote station by name, rather than by an address number.

Default Setting No-name

Do not exceed more than one RC-575 on a DCN coaxial cable network per DPS-575 system!

16 RC-575 Installation and Operation Manual

Page 35: Leirch RC-575_Synchro Controller

Version Information Chapter 3: Menu Options

RC-575.book Page 17 Thursday, May 9, 2002 2:15 PM

Version InformationReports the serial number of the RC-575 and the version numbers (or dates) of the firmware. The version numbers of the following are reported:

• Flash Firmware (with checksum)

• HTML Files

• Boot EPROM

RC-575 Installation and Operation Manual 17

Page 36: Leirch RC-575_Synchro Controller

Chapter 3: Menu Options Flash Memory Management

RC-575.book Page 18 Thursday, May 9, 2002 2:15 PM

Flash Memory ManagementThis sub-menu provides backup, restore, and file management of the RC-575’s flash memory. From this menu, firmware files can be managed, and configuration settings can be backed up.

List FilesDisplays a list of all files stored in the unit’s flash memory, including firmware files and configuration backup profiles.

File management (including renaming and deleting) of these files can be done by first selecting the file to manipulate. Select the file by scrolling through the list with the Control Knob, and pressing the Enter key to select the highlighted file.

Information about the selected file will then be shown, including the file name, size, and internal type code. Press Exit to return to the file listing, or select one of the two file management options: or

• Delete This File: Removes the file from the unit’s flash memory, making its memory space available for additional files.

• Rename This File: Changes the name the file is stored under. The new name can be up to 23 characters long, and is set by using the Enter key and Control Knob. Press the Enter key to cycle through the character position (1 to 23); the Control Knob selects a new character for that position.

Note the following rules:

• Two consecutive spaces are not allowed

• Attempting to move to the next character position after a space will return to the first character position.

Press the Exit key to store the new file name.

Backup All SettingsSaves all current configuration parameters and settings of the RC-575 into a file in flash memory.

The settings will be stored under the name NVBackupX, where X is the next available free settings profile number. Settings files can be renamed or deleted from the List Files option detailed earlier in this section.

18 RC-575 Installation and Operation Manual

Page 37: Leirch RC-575_Synchro Controller

Flash Memory Management Chapter 3: Menu Options

RC-575.book Page 19 Thursday, May 9, 2002 2:15 PM

Restore All SettingsRecalls RC-575 configuration parameters and settings from a stored settings profile. Select this option to display a list of stored settings profiles. The profile to be loaded is selected by scrolling through the list with the Control Knob, and pressing the Enter key to select the desired profile.

All current configuration settings of the RC-575 are overwritten by those in the stored profile.

RC-575 Installation and Operation Manual 19

Page 38: Leirch RC-575_Synchro Controller

Chapter 3: Menu Options Warm Reset

RC-575.book Page 20 Thursday, May 9, 2002 2:15 PM

Warm ResetResets the RC-575.

Reset to Factory DefaultsPerforms a factory reset by clearing the RC-575’s non-volatile memory.

You are asked to Cancel or Confirm the factory reset.If you confirm the factory reset, all configuration options of the RC-575 including the IP address will be reset to factory defaults. All saved settings presets will be lost.

20 RC-575 Installation and Operation Manual

Page 39: Leirch RC-575_Synchro Controller

RC-575.book Page 21 Thursday, May 9, 2002 2:15 PM

Appendix A

The Uploader Software

OverviewFirmware upgrades can be performed through web browsing software using the Ethernet 10BaseT connection, or through the Uploader software which runs on Microsoft® Windows® 95, 98, and NT 4.0. Details of using the Uploader software are provided in this appendix; for details of uploading firmware through web browsing software, see the DPS-575 Installation & Operation Manual.

This section assumes that you have a working knowledge of the Windows® operating system, and that the RS-232/422 port of the RC-575 unit is connected via a serial cable to one of the RS-232 serial ports on your PC.

Be sure to check the Leitch web site (www.Leitch.com) frequently for updates to the Uploader software, and for updated firmware for the unit.

RC-575 Installation and Operation Manual 21

Page 40: Leirch RC-575_Synchro Controller

Appendix A: The Uploader Software Software Installation

RC-575.book Page 22 Thursday, May 9, 2002 2:15 PM

Software Installation

Download From Website1. Download the Uploader software from the Leitch website,

(www.leitch.com).

2. If you have downloaded the Uploader software from our web site, unzip the file into a directory on your hard drive. (The ZIP file format is a compressed format commonly used for file distribution; utilities to uncompress ZIP files are readily available on the web).

CD-Rom1. Open the directory where you unzipped the files (or the CD-ROM

containing the Uploader software), and double-click the Setup icon. The installer will run.

2. Follow the on-screen instructions to install the software onto your system. You may accept the default locations for the software to be installed on your system, or select a directory of your choice. The software will be copied to the appropriate location, and you will be prompted when installation is complete.

Starting the SoftwareThe Uploader software is started by selecting it from the Programs menu of the Windows® Start button. Find the software in Start>Programs> DPS>Uploader. You can run the program from here, or create a shortcut to it on your desktop for convenience.

22 RC-575 Installation and Operation Manual

Page 41: Leirch RC-575_Synchro Controller

Using the Software Appendix A: The Uploader Software

RC-575.book Page 23 Thursday, May 9, 2002 2:15 PM

Using the SoftwareThe first time you run the Uploader software, you will need to set your serial port configuration in the Connection Type section. Select the serial port on your computer to which you have connected the RC-575. Once you have chosen the correct serial port, click the Save Settings button; your serial port choice will then be remembered whenever you run the software.

Figure A-1. Uploader Utility

The following file types can be uploaded to the RC-475. The unit recognizes file types based on their filename extension. For example, with the filename filename.ext, the following types are recognized, where .ext is one of:

.frm:Firmware upgrade file

.htdb:Ethernet control upgrade file

If you have downloaded upgrade files from the Leitch web site, you have unzip them before they can be uploaded to the unit (see "Software Installation," on page 22) .

When upgrading the firmware of the units, it may be necessary to delete the existing firmware files from the unit before uploading the new ones if the unit’s memory is almost full. This is a side effect of a safety mechanism of the firmware upgrade process — old firmware is not deleted from the unit until it is confirmed that the new firmware file has been received successfully in its entirety. As a result, uploading firmware

RC-575 Installation and Operation Manual 23

Page 42: Leirch RC-575_Synchro Controller

Appendix A: The Uploader Software Using the Software

RC-575.book Page 24 Thursday, May 9, 2002 2:15 PM

requires there to be sufficient free space to store the new firmware files as well as the old ones; once the new firmware files are validated, the old firmware files will be deleted. In cases where available memory is limited and there are multiple firmware files to be uploaded, it is advantageous to upload them one at a time (instead of as a batch); deletion of old firmware files is done only after all files in a batch are uploaded, so a batch upload would require enough free memory to store all new files.

To delete old firmware files prior to uploading new ones, use the Flash Memory Mgmt option of the System Config menu. (See Chapter 3, "Menu Options," on page 18 for details.)

Uploading FilesTo upload files to the RC-475, ensure that the unit is on and that the serial port settings of the Uploader software are correctly set for the connection between the PC and the unit.

Build a list of files to be uploaded by using the following buttons:

Add Files Click this button to bring up a standard Windows® file requester, and to select the files you wish to upload. Use the Files of Type pull-down list to choose between browsing for firmware files, and image/animation files. Select the files you wish to add to the list, and then click Open. You can use the Add Files button multiple times to add files from multiple distinct locations to the list.

Remove Click on a file in the list of files to be uploaded, and then click the Remove button to delete it from the list.

Remove All Click this button to clear the list of files to be uploaded.

Once all of your desired files have been added to the upload list, click the Start Upload button to begin the transfer.

First, the software will try to establish a connection with the RC-575. During this time, a button labeled Cancel Connection Attempt appears. Click this button to abort the upload attempt. Use of this button may be necessary if the software is unable to establish a connection to the unit. If a connection cannot be established, the Connection Type may be set to the wrong serial port, or there may be a physical connection problem with the serial cabling.

24 RC-575 Installation and Operation Manual

Page 43: Leirch RC-575_Synchro Controller

Using the Software Appendix A: The Uploader Software

RC-575.book Page 25 Thursday, May 9, 2002 2:15 PM

Once a connection has been established, all indicators on the RC-575 will light up, and the display panel will show the progress of the File transfer. A progress status bar in the Uploader software shows similar information. If there is insufficient memory in the unit to receive the new files, a corresponding message displays, and the Upload will not begin.

During the transfer of files, you may click the Stop Upload button to abort the upload process. Do not stop the upload process by any other means (such as by powering down the unit), as this may leave corrupt files in the unit.

Once all selected files are uploaded, a dialog box informs you of completion and the number of files transferred successfully.

RC-575 Installation and Operation Manual 25

Page 44: Leirch RC-575_Synchro Controller

Appendix A: The Uploader Software Using the Software

RC-575.book Page 26 Thursday, May 9, 2002 2:15 PM

26 RC-575 Installation and Operation Manual

Page 45: Leirch RC-575_Synchro Controller

Leitch Incorporated ("Leitch") warrants to each original end-user purchaser orlicensee (each, a "Customer") of hardware or software products manufactured byLeitch (each, a "Product"), or of non-warranty repair or other services provided byLeitch ("Services"), that each such Product and all such Services will be free fromdefects in materials and workmanship that adversely affect the Product'sperformance or the Services' intended purpose for a period (the "Warranty Period")of:

One year for server hardware Products;Two years for non-server, and Desktop hardware Products;Ninety days for parts, assemblies and supplies to support hardware Productspreviously sold to Customers;Ninety days for media of software licensed separately from Leitch hardwareProducts, and encoding created by Leitch as physically affixed on or embeddedin such media;The same period as the hardware Product warranty for media of softwarelicensed as an integral part of any Leitch hardware Product, and encodingcreated by Leitch as physically affixed on or embedded in such mediaNinety days for Services.

Please refer to the current "Leitch Limited Warranty Policy" for a completedescription of the warranty provided, including important exclusions andlimitations as well as procedures for obtaining warranty service.

Warranty