LIST OF MAJOR EQUIPMENTS FOR SINDH INSTITUTE OF ORAL HEALTH SCIENCES JINNAH SINDH MEDICAL UNIVERSITY, KARACHI ITEM # DESCRIPTION OF STORE QUANTITY REQUIRED UNIT PRICE (FOR,KAR) UNIT PRICE (C&F, KAR) 01. DENTAL UNIT DOCTOR’S TRAY One-piece handpieces console easy to wipe and clean. Soft touch Control Panel for chair positions, auto cupfiller, Bowlflush, water heater, X-Ray illuminator & dental light. Swing out Swivel balance arm with air operated tray locking system. Handle for easy tray movement. 3 Hand pieces automatic over the patient delivery system. Build-in intraoral camera for Dental Unit. Disinfectant sheet on tray Spare Holder for built-in curing light / Camera. 17 inch monitor for Dental Unit System All Internal tubing are durable & long lasting. Large instrument tray. Rectangular air pressure gauge. Hand-made sewed Ultra-fiber leather cushion. Water flow control. Individual air pressure controls. One 3 way syringe for doctor with quick disconnect tip for autoclave. 3-Aseptic easy clean, tubing’s and fitting for the hand piece straight. Multi function foot operated switch. Strong compatibility with diversify and personalize combinations as you choice X-Ray Viewer (LED Based). DENTAL CHAIR Fully motorized, electrically driven, which gives smooth and non-jerky start and stop. Lowest height range should be between 300 - 450 mm to improve visibility and access. Should be made of Cast aluminium alloy frame Comfortable arm rests. Right arm swings for patient use. Synchronized Vertical compensation of backrest eliminates the uncomfortable feeling of Patient during the moving the backrest and should be seamless and disinfectable. Double articulating Head rest adjustable for neck positioning & pediatric use also. Three Preset Positions. One touch pre-set Positions. One touch zero return system. 50 NOS.
Transcript
Page 1: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

LIST OF MAJOR EQUIPMENTS FOR SINDH INSTITUTE OF ORAL HEALTH SCIENCES JINNAH SINDH MEDICAL UNIVERSITY, KARACHI

ITEM # DESCRIPTION OF STORE QUANTITY

REQUIREDUNIT PRICE (FOR,KAR)

UNIT PRICE (C&F, KAR)

01.DENTAL UNIT

DOCTOR’S TRAY One-piece handpieces console easy to wipe and clean. Soft touch Control Panel for chair positions, auto

cupfiller, Bowlflush, water heater, X-Ray illuminator & dental light.

Swing out Swivel balance arm with air operated tray locking system.

Handle for easy tray movement. 3 Hand pieces automatic over the patient delivery

system. Build-in intraoral camera for Dental Unit. Disinfectant sheet on tray Spare Holder for built-in curing light / Camera. 17 inch monitor for Dental Unit System All Internal tubing are durable & long lasting. Large instrument tray. Rectangular air pressure gauge. Hand-made sewed Ultra-fiber leather cushion. Water flow control. Individual air pressure controls. One 3 way syringe for doctor with quick disconnect

tip for autoclave. 3-Aseptic easy clean, tubing’s and fitting for the

hand piece straight. Multi function foot operated switch. Strong compatibility with diversify and personalize

combinations as you choice X-Ray Viewer (LED Based).

DENTAL CHAIR Fully motorized, electrically driven, which gives

smooth and non-jerky start and stop.

Lowest height range should be between 300 -450 mm to improve visibility and access.

Should be made of Cast aluminium alloy frame Comfortable arm rests. Right arm swings for patient

use. Synchronized Vertical compensation of backrest

eliminates the uncomfortable feeling of Patient during the moving the backrest and should be seamless and disinfectable.

Double articulating Head rest adjustable for neck positioning & pediatric use also.

Three Preset Positions. One touch pre-set Positions. One touch zero return system. Emergency stoppage by single touch of switch. Foot control for chair Up/Down and Back/forward

movement. Smooth seamless upholstery in a large selection of

colors. Transparent & protective foot rest cover. No chair movement when any hand piece in use. Elevations system to assist all patients for easy

seating. From small children to elders (Lowest level: 500mm)

Soft seat holds patient’s gently in place and gives ease of mind.

Classic round foot control stain less steel with

50 NOS.

Page 2: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

water/ without water switch chip button pressure control systems.

Should have integrated power supply for fiber optic handpieces, piezo electric motor etc

All the outlet & inlet for the services to the chair should be concealed in the box to be atthe foot area of the chair or within the unit, asan infection control measure.

Should be with minimum 5 delivery ports forvarious handpieces, scaler and 3-way syringe(tip autoclavable, with 6 spare tips)

Should have minimum two high Speed AirRotor terminals with water control on coupling with at least one fiber optic terminal.

DENTAL LIGHT 12V,100w, 20,000 day light for perfect Matching of

colors, With luminosity of 50000 lux and 25000 lux with

maximum degrees of rotation of light armMovements

LED light 5000 K cool light or similar high quality light

Triple intensity operatable from touch control panel & Dental light On/Off Switch.

Automatic On/ Off function with chair movement. Focus system 70cm Distance. Light Head with axial movements - Horizontal,

Vertical, Axial and diagonal adjustment Air cylinder stable to stand any position. Touch light dental light with sensor. Cold led light, heatless, shadow less. Large round reflector shade heatless. Input: AC-240/220/110V, 50/60 Hz.

CUSPIDOR UNIT One piece spittoon. 90o rotatable Assistant Arm. Interruptible time controlled automatic cup

filler(adjustable). Interruptible time controlled automatic Bowl flush.

(adjustable) Strainer Basket for Bowl. Solid collector / Filter for SE & HVE One 3 way syringe with quick disconnect tip for

autoclave. High volume evacuator (air operated). Saliva Ejector (Water operated). Water heater. Built-out injection purified water system. Autoclavable 3-way syringe

JUNCTION BOX Air Filter & Regulator Water Filter Air & Water supply lines. Safe electrical compartment with Transformer, fuse,

main Switch etc. to give output. 24 VAC for safety. Main 220/240V. Outing’s one-gang, weatherproof boxes have

reinforced connector outlets and come with an innovative, powder-coated finish that promotes maximum durability, weather protection and scratch resistance.

They come standard with detachable lugs, two closure plugs and ground screws, making installation fast and easy.

Doctors STOOL Cast-metal/alloy base with five tile castors Two way adjustable lumbar support

Page 3: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Integral Gas cylinder for height adjustment Height range between 400 - 700 mm

Ass i s ta n t 's s t o o l

Cast-metal/alloy base with five tile castors Height adjustable torso support with height

adjustable foot ring Height range between 500 - 800 mm Integral Gas cylinder for height adjustment

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02.

DENTAL X-RAY INTRAORAL

Option for wall mount/ mobile stand X‐ray unit should be supplied with lead free

Apron Reusable Digital X-ray holders

Technical Data: Type DC Rated Electrical Power : 0,430Kw Tube : DG 073B DC Supply Voltage : 230/240 V (50Hz) -6A Intermittent Operation : 1s exposure: 60 s reset max Focal Spot : 0.7mm IEC 336 Total Filtration : 2mm AL Anodic Current : 8mA

Minimum range of exposure time range – 0.02 to 3.2 secs,

Stand Complete Imported Standard Set. Tube voltage 55kVp-70kVp Tube current 4mA-7mA Focus 0.8mm Distance from focus to skin 200mm Power supply 220VAC±22VAC,

50Hz±1Hz Arm length 195cm or 230cm Electrical safety for dental x‐ray unit conforms to

standards for electrical safety IEC‐60601 / IS‐13450

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NOS.

03.X-RAY PORTABLE

Convenience of cordless: Use the charging battery-pack of loading/unloading type

Incredible reduction of X-ray exposure: Up to 1/7 of existing X-Ray systems

More compact size and weight than existing portable dental X-ray (2Kg)

Adopting high-frequency circuit of inverter type Simultaneous using of digital sensor and film is

possible User control time set: Time set-up of exposure

on the location of teeth More than 300 radiography is possible with one

time charging of battery Image checking in real-time by built-in TFT LCD Acquisition of X-ray images of high quality

using built-in diverse image processing technology

The big capacity of memory device to manage and to storage the taken images.

Transmission of X-Ray images to PC by way of USB cable

Whole in one style / Battery Type of Digital Dental X-ray

Dental X-Ray Machine X-ray generator high frequency

01 NO.

Page 4: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Tube voltage60kV (fixed)

Tube current2mA (fixed)

Tube typeStationary

Tube focal spot0.8mm

Target angle20°

Exposure time (increase 0.05sec) 0.05~1.35sec

Power requirementDC 14.2~16.8V

Weight2.2kg

DetectorFilm / Digital Sensor

Power supplyRechargeable battery

Display3.5"TFT-LCD (radiation imager

display) Image processing

Brightness/contrast/invert/zoom/mirror Connect with sensor

E2V (38-20 / 78-20 / 76-40)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

04.OPG WITH CEPHIt produce panoramic imaging with exceptionally wide anterior layer thicknes and Coupled with a digital panoramic radiography system, coupled with a digital cephalometric radiography system, the wide anterior layer thickness ensure good visualization of both the crown and apex even the patient with malocclusion, it utilize the central Panoramic projection technique resultant in automatically correct imaging geometry.

High frequency DC generator. Adult and Child panoramic programs. Standard adult or child panoramic Left or right semi-panoramic Reduced dose panoramic Bitewing mode Incisive block Maxillary sinus Panoramic with improved orthogonality TMJ open/closed mouth 4 quadrants / Topographic slices Ceph Programs Ceph : A choice of 5 formats Ceph frontal: 24 x 22 cm Ceph lateral: 18 x 22 cm, 24 x 22 cm, 30 x 22 cm Carpus Mobile sensor: Cephalometric in flexible and affordable mode The choice, depending on the use (panoramic or Cephalometric), of a single sensor mode or with Two sensors. Each sensor can be moved using its Ergonomic handle that facilitates the transfer. Evaluative, simple, fast In a blink of an eye, the panoramic unit captures

detailed panoramic exams. The Cephalometric option extends the capabilities from

the Imax Touch / 3D by acquiring X-rays from the skull and carp us & 3D option

Volumetric x-rays. 3D Ready the 2D-3D evolution Your panoramic unit is pre-prepared to integrate

the 3D module, it is the natural evolution Of your unit into the Touch 3D to provide the

benefit t from the acquisition in three

01 NO.

Page 5: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Dimensions for Implantology and for even more precise exams for endodontic.

100% compatibility with software Sectional imaging (1-5 panoramic imaging section). Open and closed bilateral TMJ program. The automatic KV exposure setting adjuster the KV

valve according the selected program and patient head width.

Panoramic & Cephalometric unit can be operated with single high quality CCD Ceph sensor

Stainless steel CCD sensor designed for high durability

4-Point head supported 3, panoramic positioning light

Intuitive and user-friendly windows-based PC user interface Motorized vertical movement

Window software offer a comprehensive set of image tools for your day to day Image Need.

COMPUTER WITH LCD (08 QUNITITY)

1x Server Core i7 Hard Drive 1TB+ 9x. Client Core i3 Hard Drive 500Gb. 18.5" LCD Monitors with Keyboard & mouse With Complete wireless networking Digital Printer (x-ray Sheet)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

05.DIGITAL IMAGING SENSOR PL

Lightning fast: image readout completed in seconds. Repeatable image quality automatically, without

special training. Advanced image processing technology. Minimized need to adjust images. Virtually no under - or overexposures. No need to change exposure settings for each

patient. One step handling, fully daylight operation. True cordless best for multi surgeries. Uniquely hygienic for improved patient and user

safety. Touch less operation, protective covers, liquid

proof bags. Patient comfort with new latex free, food grade

hygiene bags. New generation of durable, cordless, thin and

flexible imaging plates. Re-usable plates, sizes equal to intra oral films

(0, 1, 2, 3 & 4C) Readable. Imaging plates are as easy to position into

patient’s mouth as film. Small footprint with many installation options. Compatible with all intra oral x-ray unit.

Technical Data: Technology Imaging plate

PSP = Photo Stimulable gold plate Pixel size (selectable) 30µm (SUPER RESOLUTION) 60µm (HIGH RESOLUTION) Resolution 17lp/mm Readout time 5-10 seconds (depending on

the plate size) Connection Standard network connection

(Ethernet RJ45) Dimensions (H x W x D) 152 x 227 x 308mm (6 x 8.9 x

12,1") Weight 3.5kg (7.7lbs) Operating Voltage 100-240VAC, 50/60Hz Operating System Windows Vista or Window 7 Sensor technology: CMOS

01 NO.

Page 6: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Outer dimensions of the sensor (length x width x thickness): 39 x 25 x 5 mm (T1) 43 x 31 x 5 mm (T2 Sensitive surface: 30 x 20 mm (600 mm2) - (T1) 34 x 26 mm (900 mm2) - (T2) Surface in pixels: 1500 x 1000 pixels (T1) 1700 x 1300 pixels (T2) Sensor resolution: > 20 pl/mm (T1 and T2) Sensor cable length: 3 m Grey levels: 14 bits (16384 grey levels) Connation: Standard USB: USB 2.0 High-Speed (480Mbit/s) and USB 3.0.

Imaging plates set Size#0x1, Size#1 x2, Size#2x6, Size#3x1,

Size#4Cx1setProtective Covers & Hygeinic Bags for all sizes.User’s software.Installation manual for software.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

06.

CENTRAL COMPRESSOR For 25 workstation Comprising. Three Motors three phase 1700rpm. Output power: 3~ 50Hz-2.2 kW 12A

Dust Free, Moisture Free, 3 Hp Motor Pumping capacity 1500 l/min Mounting on Tank Tank Capacity : 300 L Noise level: 81dB(A) Automatic Dryers with Drain system Air Filter with Regulator. Automatic safety release valve Digital Display for Power supply.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

04 NOS.

07.CENTRAL SUCTION

High power Motorized suction System Suitable for 25 Dental Units.

Individual separator for 50 unit Mechanical and Electrical Air bleed Opening System,

Controlled with P.L.C (programmable Logic Controller.)

Three phase motors type Output power: 2.2 / 3.5 kW-12A 50/60Hz 3600/rpm each

motor Control Panel board with VSD Inverter, safety Switch Digital Display for Power supply. Automatic Drainage system with Amalgam Separator Max. vacuum level: 240mbar (continuous service) Max. flow: 5000 l/min Noise level: 77dB(A)

Electronic /Electric Panel With Electronic Level Sensors and Automatic Washing System.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

03 NOS.

Page 7: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

08.

HIGH SPEED AIR TURBINE FIBER OPTIC Ultra push Chuck, Ceramic Ball Bearing Maximum Speed 400,000 rpm Autoclave-able Clean Head System

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

20 NOS.

09.

SLOW SPEED AIR MOTOR External water spray Having facility to rotate the

bur clockwise and anti-clockwise) Maximum Speed 25000 rpm with Straight Hand pieces

1:1 Direct Drive. Max Speed 40000 rpm For HP burs (Ø2.35)

Contra Angle Hand piece 1:1 Direct Drive, For CA burs (Ø2.35) Push button chuck.

Max Speed 30000 rpm

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

15 NOS.

10.

LIGHT CURING UNIT Rechargeable pen type curing light Easy to use with one touch button General curing mode for 10sec & slow rise mode for

30 sec Non light guide tip Li-ion battery without memory effect Output intensity 1200-1500 Mw/cm2

Wavelength 450-480 nm Rechargeable battery

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

10 NOS.

11.

DENTAL SCALER (PEIZON) Built in Kit Feedback system for built in circuit module keeps

constant strong power. Regulator controls output power moderately in

different quantity of tartar. Circuit module with digital system works more

accurately.Standard Accessories

01 Hand Piece (Autoclaveable). 03 Tips with individual tip holder. 01 Torque wrench (Autoclaveable). 01 Autoclaveable box.

Technical Specification Working frequency 25-35kHz Power supply AC 220V, 50/60Hz Water supply pressure 1-5 bar

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

20 NOS.

12.AUTO CLAVE

Auto Clave Class-B 22-23 LITER Five Stainless Steel Trays. Complete Standard Set

Special Features Provides full traceability of every single

sterilization cycle.

04 NOS.

Page 8: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

The Anti dusts filter traps impurities in the cooling air and protects the sterilizer interior and steam condensation system.

Steam generator and double head vacuum pump. The Electro polish stainless steel sterilization

chamber. Double Door locking system (electrical and

Pneumatic) Door locking mechanism which ensures the load can be

recovered in the event of a power failure. The quality of the distilled water being used is

guaranteed by the conductivity sensor incorporated in the tank and an efficient warning message/alarm system. If the water is of unsuitable quality, the sterilizer informs the user with appropriate messages prevents the use to avoid damage risks.

The quick coupling system for water filling and draining on the front section of the sterilizer simplifies and speeds up to relevant tasks. And that’s not all: it is also possible to equip the sterilizer with an automatic filling system that withdraws water from an external tank.

Technical Data Power Supply 220/240V Main Frequency 50/60Hz Rated Power 2300W External Dimension 480 x 500 x 600 mm Chamber Dimension 250 x 450 mm Tank Capacity 4.5liters Total Weight 54 kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

13.

AUTOMATIC WASHER & DISINFECTION SYSTEM WITH FORCE DRYING

Forced drying system, with warm air generator. Eco Slim Steam Condensor, 2back supply connection

for detergent & neutralizer loading. Detergent/Neutralizer dosing system with peristalic

pumps 15 to 20 washing/disinfection programs upto 95C, 6

custom programs Integrated water softner with automatic volumetric

re-generation 60F Automatic electro-mechcanical door locking system. Wash chamber and inner door made in AISI 316 EN 15883-1/2 complaint Washer chamber dimension (WxHXD) 380x590x480 3300W 50Kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NO.

14.POUCH SEALER

Electronic sealing control. Digital display with soft touch keypad

Automatic bag preparation, with pre-setting of bags quantity & length

12mm sealing band. Allow the sealing of pouches up to 300mm Automatic sealing of pouches up to 200mm integrated rool-holder.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

04 NO.

Page 9: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

15.

WATER DISTILLER Independent water distiller, complete with container Fully automatic process to produce 4Ltrs within 6Hrs

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NOS.

16.

ULTRASONIC CLEANER Heating Power: 400W, Capacity 5.7Ltrs, Ultrasonic

frequency 38KHz With Basket & Glasses holder complete with 2PVC

glasses Digital display

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NOS.

17.

PHANTOM HEAD STATION Cold shadowless operating light. Simulated dental chair assembly. Water filtrastion system. Instrument tray 3-way syringe. 3 tubing for high speed headpiece Dental stools. Phantom head with shoulder. Air suction (HVE). Waste collection system. Dental simulation training system is enforced for

the resident dental study .students will master the proper operation gesture ,understand the proper dental equipment usage and maintenance knowledge through the practice with the workbench system .all the mechanisms are powered by low voltage DC motors and ensures its operating safety.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

25 NOS.

18.

MODEL TRIMMER The Model Trimmer, water version works with the back

light disk and needs to be cooled off by a spring of water it must therefore be connected to the water supply plant with a pipe. The machine is supplied with an electro valve which turns on the water only when the engine is working.

Technical Data Speed 1400rpm Connection Aqua/Water Disk DA 147

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

08 NOS.

19.DENTAL POLISHING LATHE CUT

Polishing Lathe Map 2,For Continuos Duty, 2 Speeds 1400-2800 Rpm,500 Watt with gard Item no. 34Cmet.

Technical Info

08 NOS.

Page 10: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Speed: 1.400/2.800 R.P.M. Power: 500 Watt Sizes Mm 520x120x235 Weight: Kg.10,500

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

20.

VIBRATOR They have a removable rubber surface with counter –

sink edges for an easy cleaning. Hugh noiseless and steadiness by means of the perfect vertical movement.

Technical Features Overall size: 16x25x10 cm Useful work plane: 15 x 23 cm Absorption: 150 watt Feeding: 230v/50hz Weight 4.8kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

08 NOS.

21.

WAX POT The unit HOT WAX ,firmly maintain the wax’s

temperature, in order to leave unalterated its physical charactertics complete container of N◦4 squre basins 30x30.9 , programmable regulation-from 0 ◦C – 36 ◦ C TO 9◦C.

TECHNICAL FEATURES Feeding: 220V AC – 50Hz Temperature: 35-39◦C Weight: 700 gr

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NO.

22.

ELECTRIC WAX KNIFE (HOT WAX) A duo-option modeling station which enables two

different handpieces to be ready simultaneously. Each handpiece can have three individually programmable temperatures which can be easily switched over. The exchange mechanism of the modeling tips is a safe and simple process. Suitable for all types of wax-up work and modeling, the device is best combined with the Waxjet when making full dentures. The soft and stress-free treatment of the waxes is improved.

The instrument alloy used for the probes has superior conductivity, being 20 times more than that of stainless steel. The copper tips are gold plates for enhanced heat productivity.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NO.

23.

WEIGHING BALANCE Analytical balance range, 0.0001-120g Analytical balance range, 1g-5kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

01 NO.01 NO.

24. 02 NOS.

Page 11: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

HYDRAULIC DENTAL PRESS The hydraulic press is used by the dental technician

to mould mobile prosthesis, through the compression of the resin inside the muffle.

The hydraulic press “GD” is able to clamp up to 3 muffles and reach a maximum pressure of 400 bars, exerting on the muffles a force of 15000 Kg (150.000 n).

This is an excessive pressure and in order not to damage the muffles, the working pressure should be limited to 200 bar.

The press features a manual pump operated directly by the user through a lever.

The strength operated on the lever is proportioned to the inner pressure; therefore with an increasing pressure the strength used by the operator must increase as well. This is to avoid reaching too high pressures which could damage the machine.

The oil-pressure circuit is fully airtight and doesn’t need any maintenance.

Technical features Working pressure : 200 bar Max pressure : 400 bar Max force : 15.000 Kg Base material : hydraulic cast iron Weight : 20 Kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

25.

PLASTER DISPENSING UNIT Multifunctional turn/ push button for simple and

quick programming and programme selection Easy operation – error-free working for everyone Reproducible mixing ratio at the push of a button,

accurate to within a gram Integrated scales automatically measure the dosage

or for manual weighing Enables clean and dust free operation

Technical Data: Dimensions D/W/H: 335 x 240 x 590 mm Weight: 16,5 kg Mains supply: //220 V, 50/60 Hz Output: 95 W Capacity Powder: appr. 8 kg Time to alot 20ml: 100g appr. 30s

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

01 NO.

26.VACUUM MIXER WITH VIBRATOR

The mixer for coating and plasters can perform the entire cycle (paddling,pouring of the coating , vibration)in vacuum conditions.The incorporated vacuum pump is a “dry pump” without oil and at is entirely maintenance free . The speed of paddle is varying from 100 to 500rpm.The machine is supplied with a digital electronic trimmer that can be used to set the paddling time. As the pre-set time elapses(shown on the display), the padding stop and the pouring and the vibration can start. During the pouring of the coating , the vibrator can be turned on and the intensity regulated. All the quantities are visualized by a big LCD Display backlit. This

01 NO.

Page 12: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

vacuum paddle and pouring processing assures excellent result, with compact coating air bubbles and blowholes free.

Technical Data Power Supply 230 V-50Hz Power 300W Work plane 15x23cm Dimension(WxDxH) 15x23x9.5cm Weight 4.5kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

27.DENTAL MODELS

1. Dental model articul., maxilla and mandible.2. Dental model with click system and demonstration

articulator.3. Model tooth with caries no. 214. Model tooth with caries no. 245. Model tooth with caries no. 266. Model tooth with caries no. 467. Model tooth no. 17 with fissure caries8. Model tooth no. 21 for adhesive restoration model

teeth for Adhesive restoration exercises with etching gel.

9. Model tooth no. 24 for adhesive restoration model teeth for Adhesive restoration exercises with etching gel

10. Model tooth no. 26 for adhesive restoration Adhesive restoration exercises with etching gel.

11. Model tooth no. 46 for adhesive restoration model teeth for Adhesive restoration exercises with etching gel.

12. Model tooth no. 21 enamel-dentine-pulp-simulation anatomically Designed enamel, dentine a. pulp layers sensible hardness diff. between enamel a. dentine red pulp shining through if approached too closely during preparation.

13. Model tooth no. 24 enamel-dentine-pulp-simulation anatomically designed enamel, dentine a.pulp layers sensible hardness diff. between enamel a.dentine red pulp shining through if approached too closely during preparation.

14. Model tooth no. 26 enamel-dentine-pulp-simulation anatomically designed enamel, dentine a.pulp layers sensible hardness diff. between enamel a.dentine red pulp shining through if approached too closely during preparation.

15. Model tooth no. 46 enamel-dentine-pulp-simulation anatomically designed enamel, dentine a.pulp layers sensible hardness diff. between enamel a.dentine red pulp shining through if approached too closely during preparation.

16. Partially dentate upper jaw 17. Partially dentate upper jaw 18. Partially dentate upper jaw 19. Partially dentate upper jaw 20. Support with dental model 21. Rubber moulds for model (maxilla and mandible

duplicates of) to fit model teeth 22. Model tooth for pulpotomy exercises filled with wax.23. Pediatric anaesthesia model with holder HA incl.

syringe.24. Desk support for dental models.25. Spare battery for anaesthesia models.26. Syringe for training model

01 NO.

Page 13: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

27. Endodontic tooth No. 21 model teeth with root canals, fitting models, execution in transparent plastic material with red pulpal walls and ivory crowns in hard thermosetting material for preclinical training in root canal treatment and cavity preparation.

28. Endodontic tooth No. 24 model teeth with root canals, fitting models, execution in transparent plastic material with red pulpal walls and ivory crowns in hard thermosetting material for preclinical training in root canal treatment and cavity preparation.

29. Endodontic tooth No. 26 model teeth with root canals, fitting models, execution in transparent plastic material with red pulpal-walls and ivory crowns in hard thermosetting material for pre-clinical training in root canal treatment and cavity preparation.

30. Endodontic tooth No. 46 model teeth with root canals, fitting models, execution in transparent plastic material with red pulpal walls and ivory crowns in hard thermosetting material for pre-clinical training in root canal treatment and cavity preparation.

31. Edentulous maxilla a.mandible normal bite without undercuts execution in hard plastic.

32. Rubber moulds for model for casting plaster duplicates normal bite.

33. Rubber mould.34. Dental hygiene model with pink transparent gingiva.35. Pathological mandible natural size w.hinged segment

representing the nerve system and the roots supp. pulp infection and an impacted wisdom tooth caries, calculus and a sagittal section through crown and roots of tooth 44.

36. Patholog. molar socket model scale 5:1 lateral exposure repr. caries, calculus, abscess, abrasion and suppur.

37. Caries demonstration model scale 5:1 with 3 removable sectioned teeth representing caries progression in 3 stages and pulp affection.

38. Sectioned molar demonstr. model scale 2.5 : 1 representing tile nerve system and the roots a crown with inlay and an amalgam filling an abscess and an impacted wisdom tooth with signs of dissociation by inflammation.

39. Demonstration model with individual contact points.40. strip crown forms, glass-clear.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

28.

DENTAL MOULDS1. Rubber moulds for model for partial denture (upper

&Lower Jaws)2. Rubber moulds for model for complete denture(upper

&Lower Jaws)05

29.HANGING ENGINE

Complete with gear type connection, 180W, 25,000rpm.

Complete with standard accessories

04 NOS.

Page 14: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

UK/USA/JAPAN/GERMANY OR EQUIVALENT

30.

PRESS DOUBLE FLASK FLAT BENCH PRESS FOR 2 ALLOY FLASKS (UPPER+LOWER). UNIT WEIGHT IS

2.175KG The castings of the flasks shall be clean and free

from surface and casting flaws. The finished castings shall have a reasonably good finish and shall require no further machining except at the mating lugs. All sharp edges shall be rounded off. The two halves of the flask shall engage without any jerk and shall not leave any gap at the mating -edge when observed against light.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

1O NO.

31.

FLASK Dimensions and requirements of dental flasks for

lower and upper dentures. Material- Aluminium alloy, Designation A-6M of IS:

617-l959* or brass, Grade 3 of IS: 292-196lt. The castings of the flasks shall be clean and free

from surface and casting flaws. The finished castings shall have a reasonably good finish and shall require no further machining except at the mating lugs. All sharp edges shall be rounded off. The two halves of the flask shall engage without any jerk and shall not leave any gap at the mating -edge when observed against light.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

1O NO.

32.

JUNIOR PROSTHETIC LAB/WORK STATIONS(DOUBLE WITH 2 STOOLS)

It is made of parkerized cold-rolled sheet and should be painted electristatically with imported paints.

Table board is made of high density fireproof material(parkerized)

Equipped with cold light lamp, stainless steel working plate form two elbow supports, autoretrieve air gun, vaccum device & Storage device.

Height of table can be adjustable according to person.

Power 800W x 2 Dimesion 160x71x100cm 150kgs.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

13 NOS.

33.POLYMERIZING UNITS

The polymerizing units ACRYDIG are completely built in stainless steel and painted.

No electric component may come in contact, even accidentally, with water or steam, in conformity with the European Directives.

The special design of the machine closing cover avoids any scattering of vapours or condensate dripping, thus insuring the polymerization cycle is run in steam-saturated air.

The wide opening and the proper dimensions of the

01 NO.

Page 15: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

polymerisation tank permit uniform arrangement of the flasks.

Due to its programmability, the ACRYDIG will run a polymerization cycle and automatically switch off at the end of the cycle itself, the flasks cool naturally, thus avoiding the resin micro-fractures, usually caused by an excessively aggressive cooling.

Instruments The digital controller built in the ACRYDIG

polymerization units, makes programming extremely simple (3 keys only).

The program is indefinitely stored. The cycle is started or stopped through the RUN key. Every cycle step is continuously displayed.

Working cycle X1 Raising to the pre-polymerizing temperature A1. A1 Pre-polymerizing temperature. T1 Pre-polymerization period. X2 Raising to the polymerizing temperature A2. A2 Polymerizing temperature. T2 Polymerization period. STOP Acrydig automatic switching off . Power supply Cod. Art. ACRYDIG 4 220 / 240 V - 50 / 60 Hz - AD044 110 V - 50 / 60 Hz - AD041

Technical data Max. consumption : 1400 W Inside Width : 26 cm Inside Depth : 31 cm Inside Working height : 26 cm Capacity : 10-18 muffole Outside Width : 30 cm Outside Depth : 42 cm Outside height : 38 cm Net weight / Gross weight : 10 kg / 11 kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

34.

SURVEYOR Surveyor with one (1) swivel arm and central

articulated joint, ideal for prosthesis framework design.

Kit of accessories Model-holder FIXIT. 1 wax chisel. 1 scanning needle probe. 3 undercut gauges. 1 carbon marker holder. 1 Ø 3 mm Collet. 1 Ø 2.5 mm Collet.

Technical Data. Width : 19 cm Depth : 20 cm Height : 31 cm Net weight / Gross weight : 4 kg / 4,5 kg

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

02 NO.

35.AMALGAMATOR

Mechanical Dental Amalgamator Automatic amalgamation with timer is a compact and

functionally designed mixer which assures efficient and reliable trituration with a simple operation

Excellent durability and mixing power with 4

03 NOS.

Page 16: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

capsules

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

36.

PH METER Resolution : 0.01 Ph Temperature Range : 0.0 to 100ºC (Manual

Compensation) Display : 31/2 Digit LED Display Power Supply : 230VAC ±10%, 50 Hz Calibration check facility & Calibration Error

indication for 7.00 & 4.00 pH Calibration check facility & Calibration Error

indication for 7.00 & 4.00 pH.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

01 NO.

37.

MICROMOTOR (BENCH TOP) Laboratory micromotor 70 Watt,50,000 rmp.

Recommended for bridges crowns and resins.Optimal quality/price standerd, minimal vibration with handpice holder.

TECHNICAL FEATURES Power absorbed: 70 WATT Speed: 1.000-50.000 rmp Feeding: 230V-Hz50/60(110Vupon request) Hand piece weight: 255 Total weight: 1,7 KG Standard size collet: ǿ2,35mm(ǿ3mmupon request)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

10 NOS.

38. CERAMIC LAB EQUIPMENT1) Vacuum Denture Porcelain Furnace/Dental

Porcelain FurnaceTECHNICAL DATA:The Machine is the necessary tool for make the zirconia teeth in dental lab.suitable for all kinds of porcelain powder and ceramic materialsMax. Vacuum degree -97K paVoltage 220V /110V±10%, 50HzPower 1500W±10%Dimension 430×325×620 mmWeight 28kg

CE 

SpecificationsVacuum denture porcelain furnace 1.Max. Vacuum degree:-97K pa 2.Max.temperature:1305deg C

2) Porcelain furnace TECHNICAL DATA:

Features:200 Program Memory Expanded memory and faster logic board allows the user to use a multitude of porcelainsQuick-Cool Jet cools the muffle twice as fastNew graph-based applications that enables user to create, modify, print and transfer programs to furnaces straight from their PC.USB Port transfer programs and upgrades with a standard Flash Drive, (1) 1GB included.Larger Easy Read LCD Screen provides four lines of 20

01 EACH

Page 17: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

charactersMembrane Keys for keypad durability and less wearDetent Knob with Built-In Select Switch allows for faster and more convenient programmingImproved Muffle More insulation than previous Pro Series to save energy and costs. Rated to 2200° FUpgraded Thermocouple for unsurpassed accuracyCan accommodate 100 & 200 gram rings for more flexibility

3 Year Warranty or 3750 muffle hours on unit, muffle and thermocouple

3) PORCELAIN PRESSING FURNACE TECHNICAL DATA:

Automatically monitors the flow of the glass and senses the movement of the ceramic into the ring in real time and dramatically increases the likelihood of a complete press, even with cracked molds. Enables successful pressing of more units per ringPresses faster than conventional pressing furnaces Minimizes or eliminates the reaction layerFacilitates successful pressing with cracked molds

3-year or 3,750 muffle hours warranty4) SAND BLASTER

TECHNICAL DATA:Power supply: 220v/110v 50/60 Hz. Power consumption :< 8w. Working pressure: 4kg/cm.

Handpiece: twin pencil. Nozzle: replaceable. Nozzle materials: carbide/ceramic. Nozzle diameter:1.2mm/0.8mm. Particles size: 120m/50m. Optional accessories: dust extractor (reference,). Size 31cm42cm42cm (h w d). Package size: 38cm49cm51cm (h w d). Weight: 29kg

5) DUPLICATING MACHINE WITH DUPLICATING FLASKTECHNICAL DATA:

model duplications in little morethan 6½ minutes

bubble-free surface allowingfor repeated duplications unlike manual mixing machines

The adjustable disk allows you to align the flow, and facilitates insertion of the mixing tip

The aluminum support helps position the flask correctly on the work surface

The quick insertion system and flow shut-off valves prevent the formation of air bubbles during liquiddelivery

Adjustable bracket design is compatible with all of duplication silicone pack sizes

The start button is specially positioned to facilitate filling the flask

Dosing pump with 1:1 mixing ratio Adjustable plate for holding mixing tip Anodized aluminum support with flask alignment Adjustable container support brackets Quick container insertion with flow shut-off valve Provision for direct connection to all Elite Double

pack sizes (1kg, 5kg, 10kg) Sintered bayonet filters for air venting from tanks6) VACUME MIXTURE FOR ALGINATE AND

PLASTERTECHNICAL DATA:suitable for electronics, chemical, automotive, space, pharmaceutical, and cosmetics industries, such as LED package, lithium battery, solar cell front side paste, pharmaceutical materials, and printing-ink, etc.Standard Container        300ml container x 2 cupsRevolution Speed   0, 200~2000rpm; 100rmp IncrementRotation Speed       0, 50~1500rpm; 100rmp Increment

Page 18: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Time Setting    0 ~ 999 secondsProgram Memory       20 slotsMulti-step Mixing       1-5 steps in a slotVacuum Pump Capacity   Exhaust velocity: 195 L/min(60Hz), 165 L/min(50Hz)    Chamber ultimate pressure: 20 torr (approx. 2.6 kpa)    Vacuum pump voltage: 220V, 1 Phase    Vacuum pump power: 0.58KW    Vacuum pump cycles: 50Hz/60Hz    Vacuum time: 38 torr (approx. 5 kpa), 50 seconds                              20 torr (approx. 2.6 kpa), 60 secondsVacuum Setting   1 atm ~ 5 kpa free setting Motor voltage: 220V, 1 Phase    Motor power: AC 220VMachine Power Supply       Revolution: 1000W; Rotation: 400W    Power consumption standby: approx. 50VA     Operating: Max. 1200VAOperating Environment   10 ~ 40°C, 35~85% RH     Non-balanced Warning     Top Locking WarningWarning Features       Peripheral Cover Warning    Door Locking Warning    Overloading WarningSafety Features       Emergency Button     Vibration Sensor    Top Locking Sensor    Door Locking Sensor    Peripheral Cover SensorDimensions       765(L) x 585(W) x 840(H) mmWeight Approx. 400kg

7) DENTAL LABORATORY ENGINE TECHNICAL DATA:

Allows the light polymerizing of all acrylic and light-sensitive materials on the Market. The material to be light polimerized is placed on the rotating plate which Allows a complete light exposure. The machine is supplied with a cooling fan Located on the back, allowing long working times without any overheating of the composites.The maximum internal temperature during the light polymerization never exceeds 50 deg. C.8 fluorescent lights and I 1 50W halogen light, placed around the rotating piate allow the emission of UVA rays and white light, covering the complete spectrum of all light Curing materials (320 - 550 nm). Furthermore, the halogen lamp allows the Possibility to process polymerization cycles with heating. The light polymerization Is managed by a microprocessor electronic control, with the possibility to perform A cycle with or without the halogen lamp, to set the light polymerization time and Choose to do the final cooling or not.

8) CASTING FURNACE TECHNICAL DATA:Voltage: 220V/ 110V Power: 2500W Centrifugal rotational speed: 500rpm Maximum melting amount: 50g (CO-CR alloy) Melting duration: 30g ≤ 185s Casting radius: 21cm Casting method: Horizontal centrifugal casting Cooling method: Air cooled Motor power: 370W Vacuum pump: 120W 1440rpm Working pressure: -0.08- -0.09MPa Vacuum duration:High thermal yield• Reduced energy consumption• Compact size• Modular electronic valve• Protection against corrosion (electro galvanized steel and epoxy paint)• Stainless steel door• Monobloc cast ceramic muffle• No. of programs 30• Program regulation 0 to 19 in 3 level stages• Program regulation 20 to 29 in 6 level stages.Power supply: 230 V- 50/60 Hz, 2000 WWeight: 34 kgDimenssion : 500X390x440 mm

Page 19: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

9) WAX PORT TECHNICAL DATA:

1, It can heat four type wax simultaneity and keep them in liquid status2, There is temperature-fixed adjustment, can set the temperature needed+/-1°C;3, Good at heat conduction and insulation4, Easy to operate and use5, Melting the wax quickly and keep them in liquid status6, equipped digital CPU circuit and set/keep temperature needed;7, Easy to compare pre-set temperature and current temperature8, LED display heating automatically, LED will shut off when arriving temperature set9, easily recognize the specially situation because of accurate temperature sensor10, Voltage: 220V 50HZ /110V 60HZ11, Power: 130W

10) VIBRATOR TECHNICAL DATAA standard program key designedwith snap holders that provide secure mounts for capsulesA safety switch is attached to the hood as a protection mechanism

Strong vibration, with large vibrator and wide vibration table, enables simultaneous work on many rings (Whip Mix Heavy Duty Vibrator).Vibration reduces bubbles.Ergonomic design.Long wave or short wave options (Whip Mix Heavy Duty Vibrator).Easily detachable rubber top allows for convenient cleaning of vibration table.

Creates both horizontal plus vertical vibrations. Lateral extension bar produces vertical vibrations ensuring superior results when pouring models. Extra large rectangular vibration platform. Speed control dial provides six levels of variable vibration. Built-in suction pad vibration stabilizers. Table dimensions 10" x 6"

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

39. Infrared ThermometerTechnical dataMeasurement range -30°C to 500°C (-20°F to 932°F)

Accuracy 10°C to 30°C (50°F to 86°F): ±1°C (2°F)

Outside 10°C to 30°C (50°F to 86°F)

±1.5°C (3°F) or ±1.5% of reading, whichever is greater

Repeatability ±0.5% of reading or < ±1°C (±2°F), whichever is greater

Emissivity Preset 0.95

Response time < 500 mSec

Distance to spot size 10:1 calculated @ 80% energy

Spectral range 6.5–18 microns thermopile detector

Display resolution 0.2°C (0.5°F)

Display hold (7 seconds)

05

Page 20: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

LCD backlit

Temperature display °C or°F selectable

Ambient operating range 0 to 50°C (32 to 120°F)

Relative humidity 10-90% RH non-condensing, @ up to 30°C (86°F)

Typical distance to target (spot) Up to 2 m (6 ft)

Laser class II Single offset laser

Weight/dimensions 200 g (7 oz)

152 x 101 x 38 mm (6 x 4 x 1.5 in)

Power 9 V Alkaline battery (included)

Battery life (alkaline) 12 hours

Storage temperature -20°C to 65°C (-4°F to 150°F) without battery

Options/accessories Includes protective boot and storage holster General SpecificationsDisplay 3½ digit backlit LCD display with function indicatorsDisplay rate 1 second approx.Over range indication Audible tone sounds and ‘OVER’ appears on the LCD whenthe measurement exceeds the measurement range spec.Operating Temperature 0°C to 50°C (32°F to 122°F)Operating Humidity Max. 80% RH.Power Supply 9V batteryAutomatic Power Off Meter shuts off automatically after 7 secondsWeight 180g / 6.35 oz.Size 211 x 89 x 38mm (8.3 x 3.5 x 1.5”)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

40

Medical Oxygen cylinder Therapy Unit portable and trolley mountedTechnical Data:Flow Rate (0~3) LPM

Oxygen Purity 65% @ 3 L/min; ≥90% @ 2 L/min

Outlet Pressure 0.04 - 0.06 MPa

Noise <45dB (A)

Applied Voltage AC 220V / 50Hz ( or customized)

Power Consumption

<150 W

Size 440×340×290 mm

Weight 9.9 kg

Outlet 1

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

2

41 First Aid BoxTechnical Data:Minimum quantities for low risk establishments and activities may be considered as a general guidance leaflet on first aid. 20 individually wrapped sterile adhesive dressings (assorted sizes) appropriate for the

10

Page 21: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

activity (detectable dressings (coloured blue) should be available if catering is to be undertaken) 2 sterile eye pads 4 individually wrapped triangular bandages (preferably sterile) 6 safety pins6 medium sized individually wrapped sterile unmediated wound dressings (approx. 12cm × 12cm) 2 large sterile individually wrapped unmediated wound dressings (approx. 18cm × 18cm) 1 pair of disposable gloves.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

42

Wheel ChairTechnical Data:

Intended User adults without postural support needsDrivetrain storable lever drivetrain and pushrimsGear Ratio variable mechanical advantage from 1:1 to 3:1Frame rigid mild-steel frame with three wheelsAxles adjustable rear axle positionRear Wheels 26 in. (66 cm) pneumatic bicycle tiresFront Wheel 8 in. (20.5 cm) solid rubber front castorFootrest adjustable footrest with strapsArmrests fixed armrest with mudguardSupport comfort cushion, seatbelt, chest and foot strapsBearings bicycle ball bearings on all bearing surfacesRepairability repairable in a local bicycle shopFeaturesTechnical SpecificationsSeat Depth 14 in. (35.5 cm)Length 44 in. (112 cm)Sizes Small Standard LargeWidth 24 in. (61 cm) 26 in. (66 cm) 29 in. (74 cm)Seat Width 13 in. (33 cm) 15 in. (38 cm) 18 in. (46 cm)Weight 49 lbs. (22 kg) 51 lbs. (23 kg) 53 lbs. (24 kg)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

5

43 B.P apparatus Technical Data:Sphygmomanometer - Sphygmomanometer -Mercury Type Mercury Type Mercury Type 1 Should be Portable mercurial type. 2 Should have ISI mark. 3 Should have ON and OFF provision for mercury reservoir. 4 Should have a measuring range from 0 to 300 mmHg. 5 Should be provided with adult arm cuffs of size medium & large and paediatric cuff. 6 The control valve should have a knurled thumb control device. The leak rate should not exceed 10 mm of mercury per minute. 7 The manometer scale markings and graduations should be permanent and clearly visible and filled with pigments. 8 The internal diameter of the manometer glass tube should be 4.1 ± 0.1 mm and the thickness not less than 2 mm. 9 All plastic parts, if any used should not crack, flake, peel or disintegrate in normal use. 10 The inflating rubber bag should be capable ofwithstanding an internal pressure of 450 mmHg without leaking. 11 The inflating bulb should be soft and should not have any joints or ridges. 12 The mercury used should be clean, double distilled and of 99.9% purity. 13 The fastening arrangements of the cuff should be of hook and loop type (Velcro). 14 The threading and fastening arrangement of the cuff should show no sign of slip or failure when subjected to the maximum test conditions. 15 The rubber tubes used should have an internal diameter of

5

Page 22: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

3 ± 0.5 mm and the external diameter should not be less than 8mm. 16 The tubes should be fitted with male and female leur connectors. 17 The housing case should be of robust design. It should have press to release lock. It should have metal hinges. The tube should be secured with metal screws and clamps. It should have mechanism to hold the lid in right angles and should prevent accidental dropping. All parts should be replaceable in case of breakage.18 A cleaning brush to clean the manometer tube and a set of spare washers may be provided with each unit.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

44

Glucometer (Blood Glucose Meter) TECHNICAL SPECIFICATION 1. Should be a hand held meter 2. Should require no routine maintenance 3. Should have reading range/linearity from 20 to 600 mg/dl 4. Should have a maximum reading time of less than 10 seconds 5. Should use electrochemical technology 6. Should use a minimum blood sample less than 1.5µl 7. Should have a LCD display 8. Should have measuring unit in mg/dl. 9. Should have wide operating temperature 10.Should have a minimum memory of 50 11.Should have life time replacement offer 12.Should have easy code entry technique 13.Battery should be replaceable without using any tools. 14.Should have facility to ensure accuracy of measurements. 15.Should be supplied with three types of control solutions of each at least 20 ml 16.Should have safety certificate from a competent authority CE / FDA (US) / STQC CB certificate / STQC S certificate or valid detailed electrical and functional safety test GLUCOSE STRIPS GLUCOSE STRIPS 1. Should be able to use capillary blood samples. 2. Should have a minimum 4 months shelf life after opening the strip vial. 3. All strips should have at least one year expiry date from the date of supply. 4. 50 strips should be supplied along with the equipment. 5. Strips should be available in the local market.

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

4

45

MicrotomesTechnical Data:Features include digital section counter, 60 mm vertical stroke length, section thickness adjustable between 0.5 and 60 microns.  Low maintenance and backlash-free micrometer feed system has pre-lubricated cross roller bearings for consistent, accurate sectioning. Unit comes fully restored, serviced and calibrated to factory specifications.

Accessories Included: Low or high profile knife holder. Can be outfitted with optional screw down specimen clamp and/or non disposable steel knife holder.

Dimensions: 17′ wide X 19′ length X 10′ heightWeight: 60 lbs

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

1

Page 23: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

46

Microscopes (Compound Microscope)Trinocular polarizingmicroscope 40x-600xTechnical Data: Eyepieces: PLAN10X (22mm field of view)flat-field eyepieces with eye-guard andPL10X22mm with reticle Objectives: infinity Plan distressingobjectives: 4XS, 10XS, 40XS, 60XS Head: 30° inclined, trinocular head Midst Head: build-in analyzer and Bertrandlens, rotating range of analyzer: 90°, a dosevalue of vernier 6', being able to shift out theoptical way. With Bertrand lens diverter andfocusing handwheel, centering adjustment Compensator: λ plate (f18mm, first-order red,light path aberration: 551nm); λ/4 plate(f18mm, light path aberration: 147.3nm);Quartzose chock (12×28mm, I - IV) Nosepiece: quadruple Stage: rotatable circular, 360° rotatablecircular worktable, a dose value of mark 1, adose value of vernier 6' Condenser: NA1.2/0.22 swing typeachromatic condenser Polarizer: 360° (0°/90°/180°/270° four typegraduation) rotatable vibration, apparatuswith locking, being able to shift out the opticalway Illumination: Koehler illuminator system,6V/30W halogen bulb, adjustable brightness,CE certified Power Supply: 90V~240V fluctuate of voltage Total Overall Height of Microscope: 485mm Weight: 32 lbs Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

05

47

Transport StretcherTechnical data Maximum weight limit: 700 lbs (317.5 kg)

Overall length: 83" (210.8 cm)

Overall width:  32" (81.3 cm) or 36" (91.4 cm)

Siderail length: 47" (119.4 cm)

Siderail height above deck: 14.5" (36.8 cm)

Mattress size: 26" (66 cm) x 75" (190.5 cm) or 30" (76.2 cm) x 75" (190.5 cm)

Maximum head elevation: 90°

Maximum Trendeleburg/Reverse Trendelenburg: 18°

Floor to base clearance: 3.5" (8.9 cm) (except under the hi-lo cylinders)

Caster size: 8" (20.3 cm)

Complete with standard accessoriesUK/USA/JAPAN/GERMANY OR EQUIVALENT

05

Page 24: LIST OF LABORATORY EQUIPMENTS - Home - Jinnah ...jsmu.edu.pk/tenders/201411/SPECIFICATION OF MAJOR... · Web viewList of MAJOR EQUIPMENTS for SINDH institute of oral health sciences

Recommended