CARACTERISTICS:• High performance prismatic daylighting sistems

• Thermal isulation frames

• Maximum light transmision with 100% difussion

• Illuminates larger areas for a greater number of hours per day, reducing power consumption by optimizing the lighting

• 3 Glazing options:

– Simple– Doble– Triple

• Regulating the entry of light: the possibility of adding blades and automatic lighting control to control the amount of natural light input

Page 3: LledoSunoptics Presentation

Lledó Energía

Industrial And Commercial

Arquitectural apparience

TYPES:

Page 4: LledoSunoptics Presentation

Lledó Energía

Louvres for Lighting ControlLouvres for Lighting Control

• Easy control of daylight• For commercial, educational uses• 3 Diferent possibilities:

– Manual Control – External motor– Internal motor

Page 5: LledoSunoptics Presentation

Lledó Energía

ADVANTAGES

Provides a light transmission than other conventional skylights by 35% and a reflection-free spread 100%

Eliminates damage caused by direct sunlight

Prevents damage from UV radiation indoors

Double, triple and even quadruple glazing for superior isolation

Thermal insulation

Completely sealed corners that do not allow moisture penetration

High quality lenses

Contain thousands of tiny prismsThe prisms produce the refraction of sunlight, spreading the bright sunlight through spaceAs there is no direct sunlight, there is no danger of "hot spots"

Page 6: LledoSunoptics Presentation

Lledó Energía

COMPARISON

Lower light levelsLower light levels HoT SPOTSHoT SPOTS

Traditional SystemsTraditional Systems LLEDÓ SUNOPTICSLLEDÓ SUNOPTICS

Page 7: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – Electrical Lighting

Common Common Industrial Industrial BuildingBuilding

Lights On Lights On and Burning and Burning

Energy Energy However However

Sometimes Sometimes Still DarkStill Dark

Page 8: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – DIRECT DAYLIGHT

Skylight Skylight GlazingGlazing

First with First with clear and clear and

then then opaque opaque

domes to domes to knock down knock down

light for light for diffusiondiffusion

Page 9: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS

Sunoptics Sunoptics Prismatic Prismatic Skylights Skylights Maximize Maximize

Light Light Transmission Transmission

with the with the optimum level optimum level

of diffusionof diffusion

No Lights On!No Lights On!

Page 10: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - COMPARARISON

Page 11: LledoSunoptics Presentation

Lledó Energía

SkyCalc: Skylight Design Assistant - Tabular Results

Company Name: Gestora AndaluzaProject Description: Naves Almonte

Electric Lighting Usage kWh/yrLtg. Energy without Skylights 446.691 Lighting Fraction Saved 63%Lighting Energy w/ Skylights 164.844 Full daylighting (h/yr) 3.268

Savings from Design Skylighting System

SavingsAnnual Energy

Savings (kWh/yr)Annual Cost

Savings ($/yr)Lighting 281.847 $36.640Cooling 7.331 $953HeatingTotal 289.178 $37.593

Skylighting System Description Site Description

Skylight unit size (ft2) 28,0 Climate Location ESP_Sevilla_SWEC.wea3Number of Skylights 142 Climate Zone CZ4 (mixed, 3,600 < HDD65°F <= 5,400)

Total Skylight Area (ft2) 3.976 Building Type User_Defined_1

Skylight to Floor Ratio (SFR) 2,6% Building Area 152.847 (ft2)Effective Aperture 1,4%

Floor Area per Skylight 1.076 Elecric Lighting System DescriptionSkylight U-value 0,750 Lighting Type High Bay Metal Halide

Skylight SHGC 51% Lighting Control On/Off

Skylight Tvis 68% Light Level Setpoint 28 fc

Well Efficiency (WF) 95% Lighting Density 0,80 W/ft2

Dirt and Screen Factor 86% Connected Load 122,3 kWOverall Skylight System Tvis 55% Fraction Controlled 90%

Skylight CU 109%

LLEDÓ SUNOPTICS –TECHNICAL CALCS

SkyCalc: Skylight Design Assistant - Graphic Results Coefficient of utilization (CU) for Reference Building is 91% versus CU from design inputs is 109%

Company Name: Gestora Andaluza Effective aperture (EA) for Reference Building is 2.0% versus EA from design inputs = 1,4%

Project Description: Naves AlmonteDome Skylight Effective Aperture = 1,44%, Skylight to Floor Ratio (SFR) = 2,60% Effective Aperture of Reference Building = 02%

Average daylight footcandles (fc) Reference Building average daylight foot-candles1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Jan 0 0 0 0 0 0 0 0 4 15 35 53 67 73 69 55 36 16 5 0 0 0 0 0

Feb 0 0 0 0 0 0 0 0 7 23 50 73 88 92 87 74 53 31 13 1 0 0 0 0

Mar 0 0 0 0 0 0 0 5 18 44 71 90 104 109 105 93 71 44 18 5 0 0 0 0

Apr 0 0 0 0 0 0 1 14 35 63 90 110 121 124 118 106 86 58 29 11 0 0 0 0

May 0 0 0 0 0 0 7 23 52 82 108 129 141 142 133 118 100 75 44 17 4 0 0 0

Jun 0 0 0 0 0 0 11 28 58 89 115 133 143 147 142 127 105 81 52 24 8 0 0 0

Jul 0 0 0 0 0 0 8 25 56 88 117 140 154 157 151 138 116 89 57 26 8 0 0 0

Aug 0 0 0 0 0 0 3 17 46 81 112 134 147 149 143 130 108 78 45 17 3 0 0 0

Sep 0 0 0 0 0 0 0 11 31 62 90 110 122 127 122 106 82 52 22 5 0 0 0 0

Oct 0 0 0 0 0 0 0 3 18 47 74 90 101 101 93 77 53 25 8 0 0 0 0 0

Nov 0 0 0 0 0 0 0 0 11 27 50 67 76 79 70 53 33 14 2 0 0 0 0 0

Dec 0 0 0 0 0 0 0 0 4 15 35 52 63 66 62 47 28 14 2 0 0 0 0 0

Design Illuminance = 28 fc< 1 fc; < 14 fc; < 28 fc; > 28 fc;

Location = (not specified)

2 W/ft2

$0

$5.000

$10.000

$15.000

$20.000

$25.000

$30.000

$35.000

$40.000

0,0% 2,0% 4,0% 6,0% 8,0% 10,0% 12,0% 14,0%Skylight to Floor Ratio (SFR)

Total Annual Energy Savings from SkylightsLighting, Cooling and Heating (all fuels converted to kWh)

Design

0

50.000

100.000

150.000

200.000

250.000

300.000

350.000

0,0% 2,0% 4,0% 6,0% 8,0% 10,0% 12,0% 14,0%Skylight to Floor Ratio (SFR)

Ann

ual E

nerg

y Sa

ving

s (k

Wh/

yr)

Page 12: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 13: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 14: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 15: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 16: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 17: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS - USES

Page 18: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – CLIENTES USA

Page 19: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – WALMART CASE STUDY

Page 20: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – BAD USES

Page 21: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – BAD USES

Page 22: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – BAD USES

Page 23: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – EUROPE

Page 24: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – EUROPE

Page 25: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – EUROPE

Page 26: LledoSunoptics Presentation

Lledó Energía

SUNOPTICS CONVENCIONAL

LLEDÓ SUNOPTICS – EUROPE

Page 27: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – EUROPE

Page 28: LledoSunoptics Presentation

Lledó Energía

LLEDÓ SUNOPTICS – EUROPE


Recommended