Date post: | 30-Mar-2016 |
Category: |
Documents |
Upload: | lba-consulting |
View: | 231 times |
Download: | 2 times |
124
design: Luca Trazzi
Lux 180/260 spotlight
easy access to the lamp compart-ment
BodyDie-cast aluminium body and ring, sheet steel support bracket. The control gear compartment is created using an aluminium extrusion closed off at the ends with two die-cast aluminium caps. All fixtures are fitted with hinges which allow rotation on the horizontal axis and the vertical axis.The positioning of four screws on the outside of the ring ensures excellent gasket compression which, in turn, guarantees a watertight seal. Furthermore, one of the screws has a hinge for easy access to the lamp compartment. Anti-oxidant treatment and painted finish.
Light sourcesHalogen lamps with GY6.35 and G53 socket.
Metal halide lamp with PGJ5, G12 and GX8.5 socket.TC-TE fluorescent lamp with GX24q-2 socket.
EmissionsTwo different optics offer spot and flood emission, with halogen and metal halide lamps.
Power supplyIntegrated electronic transformer, or direct from the electricity mains.
AccessoriesFixing bracket, rods and spike.
Colours Embossed-effect grey, anthracite grey or corten finishing.
horizontal aim positioning (360°)
vertical aim positioning (240°)
Lux 180
Lux 260
for a wider range, see catalogue
125
spotlight Lux 180
Super spot optic
Suitable for the illumination of architectural details: spires, vaults and capitals.
Types of optic for Lux 180
QT-12 50 W GY6.35
L Ø Emed
3.00 0.26 1200
QT-12 50 W GY6.35
L Ø Emed
3.00 0.94 211
QT-12 50 W GY6.35
L Ø Emed
3.00 2.20 78
MH 35 W G12
L Ø Emed
3.00 0.38 4232
MH 35 W G12
L Ø Emed
3.00 0.94 872
MH 35 W G12
L Ø Emed
3.00 2.04 277
L = distance of the spotlight from the wall [m]Ø = diameter of the illuminated surface [m]Emed = average illuminance [lux]
Flood optic
Suitable for the uniform illumination of surfaces: facades, large green spaces and large architectural constructions.
Spot optic
Suitable for the illumination of large architectural details: monuments, fountains and gardens.
126
Lux 260 spotlight
MH 70 W G12
L Ø Emed
3.00 0.30 18948
MH 70 W G12
L Ø Emed
3.00 0.88 1889
MH 70 W G12
L Ø Emed
3.00 2.12 350
L = distance of the spotlight from the wall [m]Ø = diameter of the illuminated surface [m]Emed = average illuminance [lux]
Types of optic for Lux 260
Super spot optic
Suitable for the illumination of architectural details: spires, statues and capitals.
Spot optic
Suitable for the illumination of large architectural details: monuments, fountains and gardens.
Flood optic
Suitable for the uniform illumination of surfaces: facades, large green spaces and large architectural constructions.
127
50W
QT-12GY6,35
50W
QT-12GY6,35
50W
QT-12GY6,35
Ø 9
6Ø
96
Ø 1
67Ø
167
175
175
907590
90×90
Ø 7
90
Ø 28
75107,
5
90
90112
105
Ø 2
5
757
86 7932
halogen spotlight Lux 180
Light source Wattage Socket Optic W [kg] Code
AL QT-12 50 W GY6.35 SS 3.20 75400.__AL QT-12 50 W GY6.35 S 3.20 75401.__AL QT-12 50 W GY6.35 F 3.20 75402.__
Light source Wattage Socket W [kg] Code
AL AR111 75 W G53 3.20 75416.__
IP65integrated electromagnetic control gear
IP65integrated electromagnetic control gearlamp photometric data - see page 300
wall-mounting rodscode 75471.68code 75471.86code 75471.79
spikecode 75475.00
wall and floor-mounting platecode 75478.__
safety grillecode 75474.00
cable glandM16 x 1.5code 91056.00
glare reduction visorcode 75476.__
watertight mounting base for wall and floor installation, IP65 code 75470.68code 75470.86code 75470.79
ring-shaped bafflecode 75473.00
floor installation bracket (in green areas, for use with spike)code 75479.__
elliptical projection glasscode 75508.00
coloured glassyellow code 75505.00blue code 75504.00red code 75507.00green code 75506.00
accessories
128
Lux 180
129
Lux 180
130
70W
MHG12
20W
Mini MasterColourPGJ5
20W
Mini MasterColourPGJ5
70W
MHG12
70W
MHG12
4000
90˚ 90˚
0˚
H D1 D2 Em
1 0.36 0.36 4552
2 0.73 0.73 1138
3 1.09 1.09 506
5 1.46 1.46 284
Imax=4310.50 cd/klm
α=8˚+8˚ β=8˚+8˚
[m] [m] [m] [lx]
η=88%
20W
Mini MasterColourPGJ5
Ø 9
6Ø
96
Ø 1
67Ø
167
175
175
90×90
90×90
230
230
86 7932
Lux 180 metal halide spotlight
Light source Wattage Socket Optic W [kg] Code
MH 35 W G12 SS 5.50 75406.__MH 35 W G12 S 5.50 75407.__MH 35 W G12 F 5.50 75408.__MH 70 W G12 SS 5.80 75409.__MH 70 W G12 S 5.80 75410.__MH 70 W G12 F 5.80 75411.__
Light source Wattage Socket W [kg] Code
MH Master Colour® CDM-R111 35 W GX8.5 5.80 75418.__MH Master Colour® CDM-R111 70 W GX8.5 5.80 75415.__
Light source Wattage Socket Optic W [kg] Code
Mini Master Colour® 20 W PGJ5 SS 5.30 75412.__Mini Master Colour® 20 W PGJ5 S 5.30 75413.__Mini Master Colour® 20 W PGJ5 F 5.30 75414.__
IP65integrated electromagnetic control gear
IP65integrated electromagnetic control gearlamp photometric data - see page 329
IP65integrated electronic control gear
131
120
12080100
120
140
70 100
110
86 7932
accessories Lux 180
spikecode 75475.00
safety grillecode 75474.00
cable glandM16 x 1.5code 91056.00
glare reduction visorcode 75476.__
wall installation bracketcode 75472.__
ring-shaped bafflecode 75473.00
floor installation bracketcode 75477.__
elliptical projection glasscode 75508.00
coloured glassyellow code 75505.00blue code 75504.00red code 75507.00green code 75506.00
132
18W
TC-TEGX24q-2
18W
TC-TEGX24q-2
175
175
900
300
900
Ø 167
Ø 167
86 7932
Lux 180 bollard
coloured glassyellow code 75505.00blue code 75504.00red code 75507.00green code 75506.00
accessories
Light source Wattage Socket W [kg] Code
FL TC-TE 18 W GX24q-2 7.00 75403.__
Light source Wattage Socket W [kg] Code
FL TC-TE 18 W GX24q-2 7.00 75404.__
IP65integrated electromagnetic control gear
stake with buried base
IP65integrated electromagnetic control gear
stake with anchoring plate
133
35W
MHG12
35W
MHG12
70W
MHG12
70W
MHG12
70W
MHG12
35W
MHG12
165
269
280
Ø 1
25
Ø 2
60
90 130
130
86 7932
spotlight Lux 260
Light source Wattage Socket Optic W [kg] Code
MH 35 W G12 SS 7.00 75422.__MH 35 W G12 S 7.00 75423.__MH 35 W G12 F 7.00 75424.__MH 70 W G12 SS 7.00 75425.__MH 70 W G12 S 7.00 75426.__MH 70 W G12 F 7.00 75427.__
IP65integrated electromagnetic control gear
spikecode 75482.00
coloured glassblue code 75600.00yellow code 75601.00green code 75602.00red code 75603.00
safety grillecode 75481.00
ring-shaped bafflelimiting direct emission, for super spot optics onlycode 75480.00
glare reduction visorcode 75483.__
elliptical projection glasscode 75604.00
fixing bracket for wall and floor instal-lationcode 75484.__
accessories
134
135