+ All Categories
Home > Documents > Metro Duct - Naylor Industries | Clay Drainage | Plastic ... · Index of Contents Telephone: 01226...

Metro Duct - Naylor Industries | Clay Drainage | Plastic ... · Index of Contents Telephone: 01226...

Date post: 01-Jun-2019
Category:
Upload: doduong
View: 216 times
Download: 0 times
Share this document with a friend
24
Metro Duct The Complete Duct and Access System e m a i l : s a l e s @ n a y l o r . c o . u k w e b : w w w . n a y l o r . c o . u k Winners - Growing Business Winner - Best SME The MANUFACTURING EXCELLENCE Awards
Transcript

MetroDuct

The CompleteDuct andAccessSystem

e m a i l : s a l e s @ n a y l o r. c o . u k w e b : w w w. n a y l o r. c o . u k

Winners -

Growing Business

Winner - Best SME

The MANUFACTURINGEXCELLENCE Awards

Index ofContents

Telephone: 01226 790591 www.naylor.co.uk

IntroductionNaylor offer a technically advanced and comprehensive range of ducting systems. With production facilities in both England and Scotland and a manufacturing capability of over 30 million metres of ducting per year, we are well placed to meet the needs of all civils, utility and telecommunication markets.

The Naylor ducting system comprises three main components: ducting pipes, access chambers and covers and frames.

Naylor 50-300mm ducting is manufactured to BBA and BS EN61386 as required by the Highway Agency.

metrocable duct system

NaylorDucting&AccessSystems

2

7

7

8

10

16

MetroTwin and MetroFlex Twinwall Ducting

MetroSmooth PE Ducting

Commercial Chamber

General Purpose GP Duct

Access Chamber

Pole Boxes

BBA - All Naylor twinwall duct is fully compliant to the new BBA certification for sealed systems (if required) which incorporates sizes 63mm - 178mm OD in 6 metre lengths.

Metro duct is available in smooth wall, twinwall and singlewall corrugated profiles. The lightweight, flexible duct copes with trench undulations and the high impact resistance minimises special preparation of beds and eliminates the need for special surrounds in most instances.

+ Cable TV

+ Motorway Communications and Traffic Management

+ Light Rail Systems

+ Railtrack

+ Water

+ Gas

+ Electricity

+ Street Lighting and Traffic Signals

+ The duct has simple push fit joints for ease of installation and HDPE flexibility minimises the need for bends

+ Duct is colour coded to customer requirements and can be printed to individual customer specifications

+ High compression strength

+ Protects cables and reduces risk of damage

+ Water resistant if sealed and can be laid at extreme temperatures

+ High chemical resistance

BS EN50086-2.4Lic. No. KM 57808

BBABRITISHBOARD OFAGREMENT

CERTIFICATE No.

09 / H145

Applications and benefits

NaylorMetroDuctPremium Ducting System

MetroTwin and MetroFlex Twinwall Ducting

Naylor Metro twinwall ducting offers the advantages of a lightweight flexible product combined with high strength and durability. MetroTwin (sticks) and MetroFlex (coils)are designed to meet the required compression strength to current Highways specification and are supplied in various colours and markings to suit NJUG recommendations. Manufactured in polyethylene, the pipe is normally supplied in either 6 metre lengths or 50 metre coils. The external corrugated profile gives the product added strength and the internal bore is smooth to prevent cables from snagging. If required, a sealed joint

Black/Red -Electricity/Power

Orange - Street Lighting/Traffic Signal

Purple - Motorway Communication/ Street Lighting (Scotland)

Yellow - Gas

Blue - Water

Green - CCTV

Grey - Telecommunications

may be achieved by using two profile seals and a push fit coupling.

1Fax: 01226 790531 Email: [email protected]

High Density Polyethylene Twinwall Ducting

HDPE/LDPE Twinwall DuctingPrinted - Electric Cable Duct

ID/OD(mm)

ID/OD(mm)

ID/OD(mm)

ID/OD(mm)

ID/OD (mm)

Length(m)

Length(m)

Length(m)

Length(m)

PackQty

Colour

Code

Code

Code

Code

Code

Coils supplied with pre-installed draw string and coupling.

C/W Dowels and tiesas appropriate

Supplied with one coupling per length

ID/OD(mm)

Length(m)

PackQty Code

Supplied with one coupling per length. BBA Approved.

Supplied with one coupling per length. BBA Approved.

ID/OD(mm)

Length(m)

PackQty

PackQty

PackQty

Code

NaylorMetroDuctPremium Ducting System - Twinwall

Motorway Communications/PowerBlack Plain Ended

Motorway CommunicationsPurple Plain Ended

For sealed system 2 sealing rings required per 6m length.

For sealed system 2 sealing rings required per 6m length.

* Subject to minimum order quantity and lead time.+ Please Note: Pipe supplied plain ended - order couplings separately .

94/110

100/120

125/145

137/160

150/178

100/120

125/145

150/178

100/120

125/145

150/178

6

6

6

6

6

3

3

3

2

2

2

100

85

72

33

33

85

72

33

85

72

33

29120

29278

29111

29119

29112

29208

29273

29275

29347

29199

29209

Metro Twinwall - Electric - BlackHeavy Duty High Density Polyethylene Twinwall Ducting printed - Electric Cable Duct

Metro TwinwallSplit Duct

29285

29080

29210

29121

29070

29081

29242

29223

100

85

72

33

100

85

72

33

1

1

1

1

3

3

3

3

94/110

100/120

125/145

150/178

94/110

100/120

125/145

150/178

Metro Twinwall - Unmarked - Black

*Subject to minimum order quantity and lead time.

29450

29451

29452

29453

29454

94/110*

100/120*

125/145*

137/160*

150/178*

6

6

6

6

6

100

85

72

33

33

MetroDuctSealed System

6

6

6

100

85

33

29007

29388

29370

94/110+

100/120+

150/178+

MetroDuctSealed System

94/110+

100/120+

150/178+

6

6

6

100

85

33

29046

29364

29420

MetroDuct Sealed System Couplings

94/110

100/120

150/178

29226

29362

29395

32/40

40/50

50/63

75/90

94/110

137/160

137/160

MetroDuct TwinwallCoiled Ducting

50

50

50

50

50

25

50

Black

Black

Black

Black

Black

Black

Black

29020

29265

29113

29266

29267

29268

29092

Telephone: 01226 790591 www.naylor.co.uk2

ID/OD(mm)

ID/OD(mm)

Length(m)

Length(m)

Marked

Marked

PackQty

Code

Code

NaylorMetroDuctPremium Ducting System - Twinwall

Fully compliant with ENATS 12/24Issue 2007/8 for C2 Application

Supplied with one coupling per length.

ID/OD(mm)

Length(m)

PackQty Code

ID/OD(mm)

Length(m)

PackQty Code

Printed - Motorway CommunicationsPurple

ID/OD(mm)

Length(m) Colour Code

50

50

50

Printed - Motorway CommunicationsPurple

Purple

Purple

Purple

29279

29280

29019

50/63

94/110

137/160*

Orange

Class 2 TwinwallCable Duct

100/120

100/120

100/120

100/120

125/145

125/145

125/145

125/145

150/178

150/178

150/178

150/178

6

3

2

1

6

3

2

1

6

3

2

1

29516

29513

29512

29511

29616

29613

29612

29611

29716

29713

29712

25711

85

85

85

85

72

72

72

72

33

33

33

33

MetroDuct Twinwall

Supplied with one coupling per length. BBA Approved.

Supplied with one coupling per length. BBA Approved.

29043

29200

29249

29059

100

85

33

33

6

6

6

6

94/110

100/120

137/160

150/178

MetroDuct TwinwallCoiled Ducting

MetroDuct Twinwall - Street Lighting/Traffic Signal or Plain

50/6350/63*94/11094/110

100/120*100/120*137/160*137/160*150/178150/17894/110

100/120*137/160*150/178*

66666666666666

SLTSSLTSSLTSSLTSSLTS

PlainPlainPlainPlain

158158100100858533333333

100853333

2908729086290852908429083290822919829189290612935629042290522919729357

MetroDuct TwinwallCoiled Ducting

ID/OD(mm)

Length(m)

PackQty Code

Yellow

* Subject to minimum order quantity and lead time. Supplied with one coupling per length. +Please Note: Pipe supplied plain ended - order coupling separately.

*Subject to minimum order quantity and lead time.

290912909029089290882913529348290372904729124

SLTSSLTSSLTS

PlainPlainPlain

505050505050505050

50/6350/63

94/11094/110

137/160*137/160*

50/6394/110

137/160*

Metro TwinwallUtility Ducting

100

85

33

33

14

9

29045

29349

29244

29358

29411

29412

94/110

100/120*

137/160

150/178

225/266+

300/353+

6

6

6

6

6

6

3Fax: 01226 790531 Email: [email protected]

ID/OD(mm)

ID/OD(mm)

ID/OD(mm)

ID/OD(mm)

Length(m)

Length(m)

Length(m)

Length(m)

PackQty

Code

Code

Code

Code

50/63

94/110

40/50

50/63

94/110

50/63

94/110

Supplied with one coupling per length. BBA Approved

94/110 6 100 29069

Coils supplied with pre-installed draw string and coupling.Other colours available subject to a minimum order quantity and lead time.

Coils supplied with pre-installed draw string and coupling.Other colours available subject to a minimum order quantity and lead time.

Coils supplied with pre-installed draw string and coupling.Other colours available subject to a minimum order quantity and lead time.

50

50

29040

29050

50

50

50

50

50

29026

29039

29049

29094

29171

ID/OD(mm)

Length(m)

PackQty Code

* Subject to minimum order quantity and lead time. Supplied with one coupling per length. BBA Approved

94/110* 6 100 29068

NaylorMetroDuctPremium Ducting System - Twinwall

Supplied with one coupling per length. BBA Approved

* Subject to minimum order quantity and lead time. + Please Note: Pipe supplied plain ended - order couplings separately .

ID/OD(mm)

ID/OD(mm)

ID/OD(mm)

Length(m)

Length(m)

Length(m)

PackQty

PackQty

PackQty

Code

Code

Code

*Subject to minimum order quantity and lead time. Supplied with one coupling per length. BBA Approved.

*Subject to minimum order quantity and lead time. Supplied with one coupling per length. BBA Approved.

* Subject to minimum order quantity and lead time. Supplied with one coupling per length. BBA Approved

94/110* 6 100 29170

Length(m)

PackQty Code

Blue

ID/OD(mm)

Metro TwinwallUtility Ducting

Metro TwinwallUtility Ducting

Metro TwinwallUtility Ducting

Metro TwinwallUtility Ducting

Metro TwinwallUtility Ducting

Metro TwinwallUtility Ducting

29110

29350

29241

29355

29413

29414

100

85

33

33

14

9

94/110

100/120*

137/160

150/178

225/266+

300/353+

6

6

6

6

6

6

Green - CCTV Printed

29281

29351

29250

29359

100

85

33

33

94/110

100/120*

137/160*

150/178

6

6

6

6

Grey - Telecommunications

29238

29396

100

33

6

6

94/110*

150/178*

Red - unprinted*

Brown - unprinted*

Brown - Urban Traffic Control

MetroDuct TwinwallUtility Ducting

MetroDuct TwinwallUtility Ducting

MetroDuct TwinwallUtility Ducting

Yellow Coils

Blue

Green

Telephone: 01226 790591 www.naylor.co.uk4

Sizes relate to outsidediameters

Description Size (mm) Code

4 Way

4 Way

110

120

29230

29375

DIA (mm) DIA (mm)Code Code

63

90*

110

120

145

160

178

*Subject to minimum order quantity and lead time.

29127

29126

29168

29131

29130

29129

29128

NaylorMetroDuctPremium Ducting System - Twinwall

ID/OD(mm)

Length(m) Code

60

60

80

80

80

100

100

100

160

50

150

25

50

100

25

50

100

50

68075

68074

68073

68072

68071

68070

68069

68068

68066

For a sealed system, 2 sealing ringsrequired per 6m lengthBlack as standard

DIA (mm) DIA (mm) CodeCode

110

120

160

178

29107

29115

29106

29117

Black as standard

OD (mm) OD (mm)Code Code

40

50

63

90

110

120

145

160

178

225

300

29161

29167

29104

29103

29225

29101

29100

29099

29098

29415

29416

29149

29159

29156

29182

29162

29138

29164

29166

29181

29163

29141

29174

29165

29180

29183

29144

29215

29243

29022

29262

ID/OD(mm)

94/110

100/120

125/145

137/160

150/178

11¼°Code

22½°Code

45°Code

90°Code

ID(mm) Colour Code

Airtight RubberDuct Plug

Black

Black

94

100

29342

29343

Perforated Gas Duct PipeKitemarked to BS4962

Complies with TRANSCO specification. Coils supplied with coupling.

MetroCoil SinglewallDucting - Yellow

Couplings

Made from 100% recycled material.

Sealing Rings

Twinwall Bends

Supplied plain ended. Black as standard.

Order couplings separately.

Duct Spacer

End caps

Metro Duct Plug

Fully compliant with Highways Specification Series 1500

Other sizes available to order.

5Fax: 01226 790531 Email: [email protected]

NaylorMetroDuctPremium Ducting System

OD (mm)

OD (mm)

Colour

Colour

Code

Code

Black

Black

MetroCoil Junction Boxes

MetroCoil Conectors

105 Black M68132

63

105

Black

Black

OD(mm)

Length(m) Colour Code

Polyethylene Coiled DuctingStreet Lighting - ScotlandUnprintedPurple

MetroCoil Singlewall

Coils supplied with pre-installed draw string and coupling.

35

63

105

163

25

100

40

30

Purple

Purple

Purple

Purple

M68027

M68006

M68001

M68110

OD (mm) Colour Code

Black

MetroCoil Reducers

105x63 Black 68008

Ancillaries

Supplied in plastic tubs.We cannot guarantee the performance of the product ifNaylor Lubricant is not used.

Nominal 5Kn Breaking Strength.6mm Cord.

Draw Cord

Description Code

220 Metre Coil

500 Metre Drum

29264

29191

Supplied in plastictubs

Universal Lubricant

Size (Kg) Code

1

2.5

50001

50002

365m RollsPrinted as Service

Marker Tape

Service Colour Code

Electric Cable

Water Main

Gas Main

Telephone Cable

Foul Sewer

Street Lighting

Yellow

Blue

Yellow

Green

Red

Yellow

34036

34037

34038

34039

34040

34041

M29343

M29345

Telephone: 01226 790591 www.naylor.co.uk6

NaylorMetroDucting

Wall(mm)

PackQty

Description CodeID/OD(mm)

Street Lighting, Traffic Signal

Lightweight applications only.Black.

53/63*

97/107

53/63*

97/107

5

5

5

5

288

76

288

76

Street Lighting

Street Lighting

Traffic Signal

Traffic Signal

38028

38091

38059

38030

ID/OD (mm) Code

53/63

97/107

38007

38042

ID/OD(mm)

Length(m)

CodeWall(mm)

HDPE Smooth internal and external.25, 50 or 100m Coils. Black

32/37

32/37

32/37

38/44

38/44

38/44

50/60

50/60

2.5

2.5

2.5

3

3

3

5

5

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

Elec Cable Duct

25

50

100

25

50

100

25

50

38020

38023

38024

38021

38025

38026

38033

38034

Description

Supplied with one coupling per length.

Requires adequate protection during installation.Check suitability before installation. Non BBA Product

ID/OD(mm)

ID/OD(mm)

Length(m)

PackQty Code

Code

150/178

150/178

6 33 37008

37010

Commercial Duct ChamberCommercial Duct Chamber

Sizes

600mm up to 2.8m*

Fabricated to suit customer requirements.Please ask our sales team for more information.

*Subject to minimum order quantity and lead time.

MetroSmoothPE Duct

Supplied plain ended. Couplings to be ordered separately .*Subject to minimum order quantity and lead time.

MetroSmoothCouplings

MetroSmooth PEElectric Cable Duct

N-Twin HDPEGeneral Purpose Duct

N-Twin Coupling

7Fax: 01226 790531 Email: [email protected]

NaylorDuctingGeneral Purpose Ducting

Other Specialist Plastic Products

• Irrigation tube

• Waste pipe

• Packaging tubes and cores

• Smoke aspiration pipes

• Show jump poles

• Bespoke extrusions 2mm to 200mm HDPE, PP, LDPE, ABS, PVC etc

For further details on our full range of our plastic products which include:

Contact Naylor Specialist Plastics Tel 0121 522 0290

Wall(mm)

Wall(mm)

Length(m)

Length(m)

Colour

Colour

Code

Code

OD(mm)

ID/OD(mm)

*Other colours can be made. Can be made in HDPE or PP.

32

25

20

16

1

1

1

1

Black*

Black*

Black*

Black*

25/50

25/50

25/50

25/50

-

-

-

-

-

-

-

37/32

44/38

60/50

2.5

3

5

Black

Black

Black

Can be printed Electrical Cable Ducting.Also available: 20/30/40mm Black HDPE Irrigation Pipe

50/100

50/100

50/100

Wall(mm)

PackQty

CodeDia(in)

Dia(mm)

HDPE Smooth internal and external.Printed - Street Lighting, Traffic Signalor unprinted Orange.

Wall(mm)

Length(m)

Colour CodeOD(mm)

Black

Black

Black

Black

Black

2”/60

3”/84

4”/110

6”/164

8”/213

6.3

6.5

6.5

8.5

9.5

6

6

6

6

6

-

-

-

-

-

OD/ID(mm)

Wall(mm)

Length(m) Code

2

3

4

6

54

88.9

114

168

36054

36053

36052

36051

36058

36057

36056

36055

36071

36078

36079

36080

36073

36074

36075

36076

11¼°Code

22½°Code

45°Code

90°Code

Dia.(inches)

Dia.(mm)

BagQty

Dia.(inches)

Dia.(mm) Code

2

3

4

6

54

88.9

114

168

36050

36049

36048

36047

6 Metre lengths. Colour supplied depends on availability . Lightweight applications only. Check suitability before installation. NB. Requires adequate protection during installation.

2

3

4

6

54

88.9

114

168

369

125

76

39

1.5 - 1.7

1.8 - 2.2

1.9 - 2.4

2.2 - 2.9

30052

30053

30054

30055

General PurposeDuct HDPE

General PurposeDuct Bends

50

15

10

2Supplied into stock in bag quantities only.

General PurposeDuct Connectors

Supplied into stock in bag quantities only.

100

50

50

25

BagQty

Flexible Cable Ducting

Corrugated Singlewall Ducting

Smooth Wall CoiledDuctingHDPE or MDPE Ducting

LDPE Smooth Wall

Pump Tube

HDPE Smooth Wall DuctingOrange*

*Other colours can be made.**Standard Length - Other lengths can be made up to 12m max.110mm, 107mm and 90mm duct can be printed - Traffic Signal, Street Lighting, Amenity Lighting if required

Smooth Wall Ducting

6**

6**

6**

6**

-

-

-

-

110/103

107/97

90/80

63/53

3.5

5.0

5.0

5.0

Telephone: 01226 790591 www.naylor.co.uk8

Twinwall Jointing Procedure(Sealed System)

For 63mm,110mm,120mm,145mm, 160mm and 178 mm DUCT

1) Always ensure that the pipe end is free from dirt, grit, soil etc.

• Remove any damaged end sections of the pipe.

2) Place the seal within the 3rd valley of the twinwall corrugated pipe. (2nd valley for 178/150mm pipe)

• Ensure both pipe ends are raised off the ground before lubricating to ensure no grit or dirt is picked up when lubricant is applied .

3) To help place the seal in the valley lubricate valley before fitting .

• Lubricate around the outside edge of the seal and pipe, also lubricate both internal sides of the coupler using Naylor lubricant.

4) Push the coupler onto the pipe with seal, ensuring the pipe end is flush with the central stop positioned within the middle of the coupler.

5) Place the next pipe inside the coupler and push the pipe with seal into the coupler.

6) Air test - Test inline with current Highway specifications, ensuring that the correct test equipment is used (4" ‘U’ Gauge).

7) Installation - Follow all current Highway specifications, ensuring that the correct bedding material is used.

8) Pipes which require cutting to size, should be cut using a course toothed saw. Cuts should be made in the valley section of the pipe and should be square to the axis of the pipe. Before jointing, ensure the pipe ends are free of sharp edges, swarf, grit and handling damage.

9) If this procedure is not followed and Naylor lubricant is not used, the air tight system guarantee is invalid.

9Fax: 01226 790531 Email: [email protected]

NaylorAccessChamberPremium Access System

The pioneers of the prefabricated HDPE Access

Chamber were Poet Plastics in the 1980's. The

HDPE access chamber was a revolution to duct

chambers and the Poet chamber became

specified via a large number of local authorities.

Naylor’s acquisition of Poet’s business and tooling

some 10 years ago allowed the company to

complete its comprehensive duct range.

Subsequent investment in design and tooling has

allowed the company to introduce a number of

extra features and benefits designed with

engineers in mind.

Single, Double and Triple Chambers

Features and benefits

+ Manufactured in High Density Polyethylene

+ High Chemical Resistance

+ High Impact Resistance

+ Rotationally moulded on cast aluminium tooling

+ Approved by many Local Authorities and Utility Sectors

+ Depth has increased from 250mm to 335mm (3 boxes per metre depth)

+ Trepanned holes take all electricity and utility size duct eg. 63mm, 90mm, 110mm, 120mm, 145mm and 160mm

+ Easy to stack and install

+ Wide internal flange within the chamber enables the frame to fit straight onto the box, therefore direct loading is transferred evenly

+ Very versatile and suitable for most ducting applications

Telephone: 01226 790591 www.naylor.co.uk10

Installation

+ Excavate the required specified

location, to the depth of appropriate

number of chambers required,

(maximum 3 chambers), plus

additional 40mm for depth of base.

+ Install chamber centrally within the

specified trench/location.

+ Base of excavated area to be well

compacted granular material or

concrete slab is preferred. Drainage

runs within the slab are required to

allow excess water to drain freely

from the constructed chamber.

+ Before duct connection takes place,

the trepanned holes located on each

chamber will require cutting out to

specified diameter. Naylor Access

Chambers take from 63mm to

160mm OD duct pipes.

+ Allow minimum of 150mm

surrounding the chamber for solid

concrete support, which should be of

a semi-dry workable mixture.

+ Ensure concrete fill is evenly

distributed around the chamber and

level with the top surface. Concrete

the frame in at the appropriate height.

Chamber Sizes Chambers will be specified as AC / 1 / Lengths

Dimension Item Code Pack Size Colour

300 x 300 x 335 PAC6 69121 42 Black

300 x 450 x 335 PAC3 69124 35 Black

450 x 450 x 335 PAC1 69012 28 Black

450 x 600 x 335 PAC5 69123 24 Black

600 x 600 x 335 PAC12 69122 13 Black

450 x 900 x 250 PAC4 69036 18 Black

NaylorAccessChamberPremium Access System

11Fax: 01226 790531 Email: [email protected]

All covers and frames must be supported on the concrete surroundor on a concrete bedding mortar of sufficient thickness

Side and End Elevation

Composite Cover (B125) with locking frame

Each section fits directly into each other

High-StrengthHDPE

Trepanned holes to accept 63, 90, 110, 120, 145 and 160mmduct pipe

Surrounded by minimum 150mm concrete surround

Stand on well compacted base or concrete slab, complete with drainage channels toallow excess water to drain away

TOP

TOP

TOP

150mm

150mm

150mm

50mm Drain holethrough concrete

100mm

150mm

Access Chamber Specification

1. The chamber shall be of solid construction of single, double or triple height pre-formed sections (triple shown) and prevent distortion during back-fill process.

2. The chamber will meet the Highway Regulations of minimum duct cover in both footways and road verges.

3. The chamber shall have pre-trepanned cut outs areas to accept 63mm OD - 160mm OD duct except 900 x 450 which accepts 63mm -120mm.

4. The chamber is manufactured in rotational moulding high density polyethylene material.

5. The chamber shall have a C15/ST3 concrete base and surround, 150mm surround and 150mm base bedded on a 100 mm Type 1 sub base or concrete slab with a 50mm drain hole (base to be constructed first and have a smooth floated finish).

6. For traffic signal/street lighting applications the covers are non ferrous composite material and fit closely within a galvanised steel frame. The cover and frame will meet the loading requirements of BS EN 124 Class 125. The cover is black in colour and marked Naylor Drainage and the legend ‘‘Traffic Signals’’ or ‘‘Street Lighting’’ and have integral lifting keyholes. The cover has an integral anti-skid pattern on the upper surface. The frame must also be supported on the concrete surround of the chamber on a bed of mortar.

GENERAL NOTE

Chambers, when completed, must be internally free from any debris.

Telephone: 01226 790591 www.naylor.co.uk12

430

335

63-160mm Pipe inlets

300

Extra wideflange

300

Nominal dimensions (mm) W300 L300 D335

Product Reference PAC 6Code 69121

Access Box - Square

Access Box - Rectangular

580

335

420

300

450

Extra wideflange

63-160mm Pipe inlets

Nominal dimensions (mm) W300 L450 D335

Product Reference PAC 3Code 69124

NaylorAccessChamberPremium Access System

13Fax: 01226 790531 Email: [email protected]

Access Box - Square

Access Box - Rectangular

Nominal dimensions (mm) W450 L450 D335

Product Reference PAC 1Code 69012

555

335

63-160mm Pipe inlets

450

Extra wideflange

450

Nominal dimensions (mm) W450 L600 D335

Product Reference PAC 5Code 69123

780

335

63-160mm Pipe inlets

585

Extra wideflange

450

600

Telephone: 01226 790591 www.naylor.co.uk14

Access Box - Square

Access Box - Rectangular

Nominal dimensions (mm) W600 L600 D335

Product Reference PAC 12Code 69122

780

335

63-160mm Pipe inlets

Extra wideflange

600

600

Nominal dimensions (mm) W450 L900 D250

Product Reference PAC 4Code 69036

900

250

450

900

Up to120mm Pipe inlets

450

NaylorAccessChamberPremium Access System

15Fax: 01226 790531 Email: [email protected]

PoleBox

+ Stand on a well compacted bedding or concrete slab.

+ Drainage runs situated within the slab are required to allow excess water to drain away from the constructed chamber.

+ 115mm Traffic Pole is located within the pre-formed Polyethylene clamp which is located on the Pole Box.

+ A minimum of 150mm concrete surround is required to support the chamber when the chamber is fully connected to the traffic pole.

+ Ensure concrete fill is evenly distributed around the Pole Box and level with the top surface. Concrete the frame in at the appropriate level.

Installation

Specification

450 450

500

Features and benefits

1. The pole box shall be of one-piece,

structured wall design and

rotationally moulded in high density

polyethylene.

2. The pole box shall be either 450 x

450mm or 295 x 275 x 500mm in

size with an integral housing for 115 mm

pole.

3. Each point of entry shall have 63 to 120 mm

pre-trepanned cut-outs.

4. The depth of the box is 500 mm.

+ Protects cables

Easy access+

Moulded Clamp holds pole securely+

Suitable for 63mm - 120mm OD duct+

Example shown: 295 x 275 x 500mm

NaylorPoleBoxMetro Pole Box System

Telephone: 01226 790591 www.naylor.co.uk16

Pole Box - Square

Nominal dimensions (mm) W275 L295 D500

Product Reference PAC POLE 6Code 69024

300 300

Up to 120mm Pipe inlets

550

295

115

295

190

Pole Box - Square

Nominal dimensions (mm) W450 L450 D500

Product Reference PAC POLE 1Code 69025

470 470

500

Up to 120mm Pipe inlets

462

115

462

190

NaylorPoleBoxMetro Pole Box System

17Fax: 01226 790531 Email: [email protected]

Features and benefits

+ Wide external flange enables frame to fit directly onto chamber surround

+ Deep seated frame fits exactly into Chamber

+ New Anti-Slip resistance composite cover

+ Available in all key sizes

+ Approved by Devonshire County Council, Greater London Council and most Local Authorities

+ Successfully passing all SRV requirements, wet and dry

+ Loading B125

+ Stocked as standard

+ Deep seated galvanised steel framework

+ Ensures flush fitting to Naylor Access Chamber

+ Available locking as standard

NaylorCovers&FramesComposite and Galvanised

Composite Cover and Standard Frame - Square

Typical Frame Section

Dimension g

Standard Frame 3D View

Anti-Slip Composite Cover - Square

Lock in Facility

Dimension e

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Dimension f

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69128Nominal dimensions (mm) 300 x 300

Code 69127Nominal dimensions (mm) 450 x 450

Code 69125Nominal dimensions (mm) 600 x 600

691283003004104108031031295

691274504505705708047231472

691256006007207208061031610

01226 790591

EN124B125 TRAFFIC SIGNALSSTREET LIGHTING

Telephone: 01226 790591 www.naylor.co.uk18

NaylorCovers&FramesComposite and Galvanised

Composite Cover and Standard Frame - Rectangle

Dimension g

Typical Frame Section

Standard Frame 3D View

Dimension e

Composite Cover - Rectangle

Dimension f

Lock in Facility

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69129Nominal dimensions (mm) 300 x 450

Code 69126Nominal dimensions (mm) 450 x 600

691294503005504008046830317

691266004507205708061530465

01226 790591

EN124B125 TRAFFIC SIGNALSSTREET LIGHTING

Galvanised Cover and Standard Frame - Square

Typical Frame Section

Dimension g

Standard Frame 3D View

Galvanised Cover - Square

Lock in Facility

Dimension e

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Dimension f

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69101Nominal dimensions (mm) 300 x 300

Code 69099Nominal dimensions (mm) 450 x 450

Code 69102Nominal dimensions (mm) 600 x 600

691013003004104108041080295

690994504505705708057080472

691026006007207208072080610

19Fax: 01226 790531 Email: [email protected]

Galvanised Cover and Standard Frame - Rectangle

Dimension g

Typical Frame Section

Standard Frame 3D View

Dimension e

Galvanised Cover - Rectangle

Dimension f

Lock in Facility

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69098Nominal dimensions (mm) 300 x 450

Code 69100Nominal dimensions (mm) 450 x 600

690984503005504008046531311

691006004507205708061331462

Galvanised Cover and Flush Frame - Rectangle

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69069Nominal dimensions (mm) 900 x 450

6906945045010205704046830470

Dimension c

Dimension e

Dimension g

Typical Frame Section

Flush Frame 3D View

Dim

ensi

on

d

Lock in Facility

Dim

ensi

on

b

Dimension a

(1x 450x450 Galvanised Cover) (1x 450x450 GalvanisedCover)

Dimension a

Galvanised Cover - Square

Dimension f

Telephone: 01226 790591 www.naylor.co.uk20

NaylorCovers&FramesComposite and Galvanised

Pole Box Composite Cover and Flush Frame - Square

Dimension g

Typical Frame Section

Flush Frame 3D View

Anti-Slip Composite Cover - Square

Lock in Facility

Dimension e

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69158Nominal dimensions (mm) 300 x 300

Code 69159Nominal dimensions (mm) 450 x 450

691583003003753754031031295

691594504505705704046830470Dimension f

01226 790591

EN124B125 TRAFFIC SIGNALSSTREET LIGHTING

Pole Box Galvanised Cover and Flush Frame - Square

Dimension g

Typical Frame Section

Flush Frame 3D View

Codedimension adimension bdimension cdimension ddimension edimension fdimension gdimension hmeasurements in mm

Code 69156Nominal dimensions (mm) 300 x 300

Code 69157Nominal dimensions (mm) 450 x 450

691563003003753754031031295

691574504505705704047231472

Lock in Facility

Dimension e

Dimension c

Dim

ensi

on

d

Dim

ensi

on

b

Dimension a

Galvanised Cover - Square

Dimension f

21Fax: 01226 790531 Email: [email protected]

• Clay Pipes - for open trench and trenchless construction

• Hathernware - pipes and industrial ceramics for hot/aggressive environments

• Band-Seal - flexible pipe couplings

• Plastic Pipes - Twinwall ducting and drainage; land drainage

• Gardenware - The Yorkshire Flowerpot range of frostproof pots

Naylor Industries plc - more than 100 years of production and supply to the Construction Industry

TELEPHONE: 01226 790591

FACSIMILE: 01226 790531

EMAIL: [email protected]

WEB: WWW.NAYLOR.CO.UK

TELEPHONE: 01592 717900

FACSIMILE: 01592 717906

EMAIL: [email protected]

WEB: WWW.NAYLOR.CO.UK

CLOUGH GREEN, CAWTHORNE

BARNSLEY

SOUTH YORKSHIRE, S75 4AD

ENGLAND

OFF SEA ROAD,

METHIL, LEVEN

FIFE, KY8 3QQ

SCOTLAND

A MEMBER OF THE NAYLOR GROUP OF COMPANIES

NAYLOR DRAINAGE

LIMITED

Ref:

MD

09/1

4


Recommended