+ All Categories
Home > Documents > Minda Autoelektrik Limited -...

Minda Autoelektrik Limited -...

Date post: 23-Jun-2018
Category:
Upload: ngohanh
View: 222 times
Download: 0 times
Share this document with a friend
22
Transcript
Page 1: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand
Page 2: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Minda Autoelektrik Limited

STARTER MOTOR & ALTERNATOR RANGE

Page 3: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

About us

Constitution

Purpose

Plant Location

Highlight

Technology /

Quality

Promoted by Spark Minda ( Ashok Minda Group)

To manufacture Starter Motors and Alternators for Agriculture Machinery, Stationary Engine, Construction Equipment and Automotive market.

Bawal in Haryana.

Suppliers to all major Tractor OEM’s. We also export to European customers.

Compact size Reduction Gear Starter Motors and Alternators having latest international technology manufactured as per European Quality Standards being introduced in India under SPARK MINDA brand.

Page 4: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Main OEM customers

Page 5: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Key Milestones

• FY 2007-08 : Project started and commenced production for starter sub-

assemblies.

Development completed for Starter 12V 2.2 to 3 KW

• FY 2008-09 : Supply started to Sonalika and complete Starter Motors to European

customers Commenced production for 4” Alternators

100th MINDA service dealer appointed

• FY 2009-10 : ISO 9001:2008 Certification (DNV)

200th MINDA service dealer appointed

Supply started to 5 new customers

SQA plant audit cleared by TAFE, John Deere and M&M

Development completed for 5”Alternator 37A, 65A & 120A

Page 6: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

•FY 2010-11 : 300th MINDA service dealer appointed

Supply started to 4 new customers

Added one more shed for Alternator manufacturing

In-house Validation facilities established

Development completed for Starter 12V 3.5 KW & 24V 3.5 KW

• FY 2011-12 : 400th MINDA service dealer appointed

Supply started to 3 new customers

ERP implementation

Development completed for Starter 12V 2 KW

• FY 2013-14 : 514 MINDA Service Centre appointed

• FY 2015-16 : 558 MINDA Service Centre appointed

Our aim to achieve 600 service centre till June,2017

Key Milestones

Page 7: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

• MINDA selected as a source. Pilot lot under process PTL

• Under development M&M

• Under development VST & SAME

100%

70%

85%90% 90%

80% 80%

100% 100%

30%

100% 100%

0%

20%

40%

60%

80%

100%

120%

MINDA Tractors Market Share in %

Page 8: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Product Range

Starter Motor 24V 3.5kW Starter Motor 12V 3.5kW

Starter Motor 12V 1.8~3.0kW Starter Motor 12V 0.8~1.7 KW

Page 9: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Product Range

Alternator

14V 35Amps ~ 50Amps

Alternator 14V 37Amps ~ 120Amps

Alternator – Internal Fan

14V 35Amps ~ 50Amps

Page 10: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

SPARK MINDA Product sale

Total Starters supplied in Market – More than 6 Lac

Total Alternators supplied in Market – More than 5 Lac

0

20000

40000

60000

80000

100000

120000

140000

160000

180000

2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16

Page 11: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Global Market Reach Starter Motors & Alternators manufactured by SPARK MINDA are appreciated by

more and more satisfied customers in many countries…

"Star Export House" Certificate of Recognition given by the Govt. of India

for Company’s performance in exports.

Page 12: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Main Features

• Easily replaceable with Direct on Starter Motor

• Highly efficient reduction gear pinion drive assembly

• Reduced weight & dimensions as compared to direct drive starter

motors

• High torque for high specific power output

• High efficiency with low current drain from battery

• Low maintenance cost and easy to service

Page 13: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Type ACM 42 Classic

(with external fan)

Nominal voltage 12V

Nominal output 35 A to 120A

Stator diameter 108 mm to 128mm

Weight 3.9 kg to 5.4kg(with pulley)

Cut in Speed 1150 rpm

(max):1450rpm(mar)

Set point voltage 14.3 +/- 0.3V at +25°C

Regulator Multifunction / Monofunction

Rectifier Press fit, welded Avalanche

diodes

Rotation Clockwise & Counterclockwise

(viewed from pulley end)

Protection Dust & Water

Operating temperature -40° C to + 100° C

Alternator

Page 14: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Comparison –Direct Drive vs. GRS Starter Motor

S.No.

PARTICULARS

DIRECT

DRIVE

GEAR

REDUCTION

1 Weight 10 - 13 Kg 5.7 Kg

2 Specific Power 1.9~2.6 KW 2.2~3.0 KW

3 Torque 26 – 35 Nm 45 – 55 Nm

4 Efficiency 50% - 55% 60%

5 Reliability Medium High

6 Current Drain from battery High Low

7 Size (total length) 320mm 230mm

Page 15: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Main Features

• High specific current output

• High output at idle speed, resulting in enhanced battery life

• High quality Avalanche diodes and welded rectifiers

• High performance monochip multifunction regulator

• Designed to withstand high vibrations

• Compact in size – 4 inch

• Stability of output throughout the rpm band

Page 16: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Manufacturing Facilities

Page 17: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Production facilities • State of art facilities having efficient process flow and latest machinery having

capacity of more than 360,000 sets of Starter motor and Alternator per annum.

Armature Inspection Starter Body Line

Starter Motor Assembly Line Alternator Rotor Line

Page 18: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Production Facilities • State of art facilities having efficient process flow and latest machinery having

capacity of more than 360,000 sets of Starter motor and Alternator per annum.

Solenoid Assy Endurance Lab

Starter Solenoid Assy Stores

Page 19: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Quality at every step…

Online Tests for Starter Motors

Armature • Coil Resistance

• Surge

• High Voltage Flash

Stator body

• Coil Resistance

• Surge

• High Voltage Flash

Solenoid

• Pull in test

• Hold on test

• Milli volt drop test

• Winding balance test

• Insulation test

• Primary & Secondary travel check

• Temperature Compensation

• Air Leakage Test

Pinion drive

assembly

• Ultrasonic Cleaning of component

• Inspection of Smooth movement of

one-way clutch

• Slippage Torque Checking

Final assembly

• No load Performance

• Load Performance

• Lock/Stall Test

• Min. operating Voltage

Page 20: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Quality at every step… Online Tests for Alternators

Rotor • Resistance

• Surge

• High Voltage Flash

Stator

• Coil Resistance

• Surge

• High Voltage Flash

Rectifier

• Forward continuity test

• Reverse leakage test

Regulator

• Diode drop test

• Darlington drop test

• OCV test

• Droop test

• Frequency test

• IG resistance test

• Flash test

Final Assembly

• Rotor Energization

• Cut in Speed test

• Output @ different speed

• Regulating Voltage

• Zero Out Put test

• Blocking diode test

Page 21: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

DEALER NETWORK

Neighbouring

Countries

TOTAL 558

NOS.

9

22

11

1

12

14

69

EASTERN ZONE

STATE

TOTAL

ASSAM

BIHAR

JHARKHAND

NEPAL

ODISHA

WEST BENGAL

NOS.

1

41

21

54

117

STATE

NORTHERN ZONE

TOTAL

DELHI

HARYANA

H.P / J&K

PUNJAB

NOS.

48

14

29

3

44

138

STATE

CENTRAL ZONE

MADHYA PRADESH

CHHATISGARH

U.P WEST

UTTARAKHAND

U.P EAST

TOTAL

NOS.

34

42

3

22

101

STATE

SOUTHERN ZONE

ANDHRA PRADESH

KARNATAKA

KERALA

TAMIL NADU

TOTAL

NOS.

38

53

42

133

WESTERN ZONE

STATE

GUJARAT

MAHARASHTRA

RAJASTHAN

TOTAL

Page 22: Minda Autoelektrik Limited - mindaasl.commindaasl.com/uploads/e68c540bb3144fb183b0d0494d825a72.pdfcomparison –direct drive vs. grs ... west bengal nos ... nos. 48 14 29 3uttarakhand

Recommended