+ All Categories
Home > Documents > Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet...

Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet...

Date post: 04-Nov-2020
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
32
1 Møller Polarimetry in Qweak Joshua Magee William and Mary Physics Jefferson Lab Hall C October 17, 2011
Transcript
Page 1: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

1

Møller Polarimetry in Qweak

Joshua Magee

William and Mary Physics

Jefferson Lab – Hall C

October 17, 2011

Page 2: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Agenda

Qweak Experiment (overview)

Møller background

Møller systematics

Summary

2

Page 3: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Agenda

Qweak Experiment (overview)

3

Page 4: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Qweak

Parity violating ep scattering

Low Q2 (~0.026 GeV2)

High beam polarization

4

Page 5: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Qweak

Parity violating ep scattering

Low Q2 (~0.026 GeV2)

High beam polarization

4% precision

5

Error source ΔAphys/Aphys

contribution

ΔQpw/Qp

w

contribution

Counting statistics 2.1% 3.2%

Hadronic structure -- 1.5%

Beam polarimetry 1.0% 1.5%

Absolute Q2 0.5% 1.0%

Backgrounds 0.5% 0.7%

Helicty-correlated beam properties 0.5% 0.7%

TOTAL: 2.5% 4.1%

Page 6: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Agenda

Møller background

6

Page 7: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry (review)

Møller scattering

Electron-electron

Pure QED

7

γ

e-

e-

e-

e-

Page 8: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry (review)

Møller scattering

Electron-electron

Pure QED

Measure assymetry

Largest at 90° (com)

8

Page 9: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry

Superconducting solenoid magnet

Iron foil

2 quads

2 detectors in coincidence

9

Q1 Q2 Q3 Detectors

9

Page 10: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry

Superconducting solenoid magnet

Iron foil

2 quads

2 detectors in coincidence

10

Q1 Q2 Q3 Detectors

Focusing magnets

10

Page 11: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry

Superconducting solenoid magnet

Iron foil

2 quads

2 detectors in coincidence

11

Q1 Q2 Q3 Detectors

Not in use (12 GeV)

11

Page 12: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry

12

Page 13: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Møller polarimetry

High rates

~15 kHz

~1% precision in 5 min

Tune plot

Correlation

13 13

Page 14: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Agenda

Møller systematics

14

Page 15: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Systematic outlook Source Uncertainty dAsy/Asy (%)

Beam pos x 0.5 mm 0.32

Beam pos y 0.5 mm 0.02

Beam direction x 0.15 mr 0.02

Beam direction y 0.15 mr 0.01

Q1 current 2% 0.10

Q3 current 1% 0.17

Q3 position 1 mm 0.18

Multiple scattering 10% 0.01

Levchuk effect 10 % 0.20

Collimator positions 0.5 mm 0.06

Target temperature 50% 0.05

B-field direction 0.14

B-field strength 5% 0.03

Spin polarization in Fe 0.25

Electronic D.T. 100% 0.04

Solenoid focusing 100% 0.10

Total 0.57 15 *Systematics for 1 uA.

Page 16: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Beam pos.

Largest systematic

Solenoid blurs x/y

Disagreements

No angle on target

Newer transport code

Effect of quad

16

Page 17: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Magnetic saturation

Pure iron foil

saturates at 2.2T

At 3T, 2° “tilt” is ~0.4% change in polarization

17

Plateau

Saturation point of iron

Page 18: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Quad tune dependence

Will quad mis-align affect polarization?

Could we correct it?

18

Page 19: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Quad tune dependence

19

Page 20: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Quad tune dependence

Will quad mis-align affect polarization?

Could we correct it?

-91.5

-91

-90.5

-90

-89.5

-89

-88.5

0 1 2 3 4 5 6

Po

lari

zati

on

(%

)

Quad setting

Polarization vs. Quad setting

20

Page 21: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Overall

21

Page 22: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Agenda

Qweak Experiment (overview)

Møller background

Møller systematics

Summary

22

Page 23: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

23

Questions?

Page 24: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

24

Extra slides

Page 25: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Qweak

Beam parameters

Energy: 1.165 GeV

Current: 180 μA

Polarization: 85%

25

Experiment parameters

Target length: 35 cm

Hours running: ~2500

Integrated rate: 6.5 GHz

Page 26: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

The Problem

26

Upstream

Coil “pancake”

Disclaimer! This is a different quad with no probes attached. For educational purposes only.

Page 27: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

SM Prediction

27

Page 28: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Simulation Efforts

28

Real tunes

Awesome

Poor

Poisson

Page 29: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Systematics

29

Page 30: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Systematics

30

Nominal

80%Nominal 66%Nominal

33%Nominal

Page 31: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Systematics

Nominal current 80% nominal

31

66% nominal

Page 32: Møller Polarimetry in Qweak - INDICO (Indico)...Møller polarimetry Superconducting solenoid magnet Iron foil 2 quads 2 detectors in coincidence 10 ... Levchuk effect 10 % 0.20 Collimator

Looking forward

32


Recommended