MONO & MULTI
SPLIT AIR CONDITIONERS
INVERTER TECHNOLOGY ENERGY CLASS
SINGLE SPLIT DCI
IR REMOTE
www.argoclima.com
Low ConsumptionLow Noise LevelPrecise temperature set
Inverter technology: low consumption, low noise, more precise temperature control
ERP compliant; just 0.5 watt consumption in stand-by Compact & Linear Design, high-gloss pure white finishing Central very discreet display on the front panel Digital remote control with LCD display Different airflow settings; 4 fan speeds Programmable timer I feel: ensures the desired temperature in the precise place where
you place the remote control Turbo Function
Memory Function Comfortable Sleep mode Auto clean of the indoor heat exchanger Intelligent defrost: defrost process is not activated unnecessarily,
allowing significant energy saving Cold draft prevention: it prevents cold air entering during the
heating function Low Voltage start-up: low consumption at start-up, no impact on
the use of other electrical appliances Self-diagnosis Optimized airflow in cooling and heating
X3 DC inverter series is highly efficient and provides immediate and continuous comfort with low energy consumption.Moreover, some technological features are designed to reduce peak consumption to improve the functioning at low temperatures.
Cold plasma air purification system Air sterilization with removing over 90% of bacteria
Odors removal Improved air quality thanks to negative ions increasing
Standby 0,5W
Cold Plasma iFeel Energy Saving
3 Sleep CurveComfortable
Cold Air Prevention
Led Display Timer Intelligent Defrosting
Auto Clean Turbo Button Self-Diagnosis Dehumidification Auto Restart
-15°C Cooling -20°C Heating
2
MODEL (Indoor unit / Outdoor unit) X3I 27 (X3I 27 HL / X3I 27 SH) X3I 35 (X3I 35 HL / X3I 35 SH)
Units Cooling Heating Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 2,6 (0,45-3,23) 2,8 (0,45-4,1) 3,5 (0,6-3,96) 3,67 (0,6-5,13)BTU/h 9000 9000 12000 12000
EER/COP (EN14511) 3,23 3,71 3,23 3,71Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 2,6 2,6/2,8/2,6 3,5 3,0/3,8/3,0
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,1/3,2 6,1 4,0/5,1/3,2
Energy efficiency class A++ A+/A+++/B A++ A+/A+++/BAnnual energy consumption C/H(Avarage/Warmer/Colder)
kWh/annum 149 910/769/1706 201 1050/1043/1969
Air flowrate Indoor (sh.-h.-m.-l.) m³/h 560-490-430-330 660-540-460-330Dehumidification l/h 0,8 1,4Fan speeds (Indoor / Outdoor) n° 4/2 4/2Sound pressure Indoor (sh.-h.-m.-l.) dB(A) 39-36-32-26 42-39-33-26Sound pressure Outdoor (h.) dB(A) 52 53Sound power Indoor (sh.-h.-m.-l.) dB(A) 55-52-44-38 57/53/45/42Sound power Outdoor (h.) dB(A) 61 62Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 0,805 0,755 1,084 0,989Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 0,7/1,46 0,85/1,77Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Max. pipe lenght with gas standard charge m 5 5Max. pipe lenght m 15 20Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Indoor (H./W./D.) mm 275x790x200 289x845x209Net dimension Outdoor (H./W./D.) mm 540x776x320 540x776x320Net weight Indoor / Outdoor Kg 9/28 10/29
MODEL (Indoor unit / Outdoor unit) X3I 52 (X3I 52 HL / X3I 52 SH) X3I 64 (X3I 64 HL / X3I 64 SH)
Units Cooling Heating Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 5,13 (1,26-6,6) 5,28 (1,12-6,8) 6,7 (2,0-8,2) 7,25 (2,0-8,5)BTU/h 18000 18000 24000 24000
EER/COP (EN14511) 3,25 3,74 3,25 3,74Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 5,1 4,1/5,3/6,2 6,7 6,4/7,1/6,4
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,4/3,1 6,3 4,0/5,1/2,8
Energy efficiency class A++ A+/A+++/B A++ A+/A+++/CAnnual energy consumption kWh/annum 293 1435/1374/4200 373 2240/1949/4800Air flowrate Indoor (sh.-h.-m.-l.) m³/h 800-720-610-520 1150-1050-950-850Dehumidification l/h 1,8 2,4Fan speeds (Indoor / Outdoor) n° 4/2 4/2Sound pressure Indoor (sh.-h.-m.-l.) dB(A) 46-42-39-36 48-45-42-39Sound pressure Outdoor (h.) dB(A) 56 60Sound power Indoor (sh.-h.-m.-l.) dB(A) 58-54-51-48 64-59-56-53Sound power Outdoor (h.) dB(A) 63 68Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,58 1,41 1,875 1,945Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 1,3/2,71 1,9/3,97Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 12,7(1/2") 15,88 (5/8")Max. pipe lenght with gas standard charge m 5 5Max. pipe lenght m 25 25Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Indoor (H./W./D.) mm 300x970x224 325x1078x246Net dimension Outdoor (H./W./D.) mm 700x955x396 700x955x396Net weight Indoor / Outdoor Kg 13,5/45 17/53
Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.
OPERATING RANGE (outdoor temperature)Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C
www.argoclima.com
Technical data
3
MULTISPLIT DCI
ChildLock
EnergySaving
Timer 24h WeeklyTimer
R410A EasyMaintenance
HighEfficiency
Auto RestartMemory
IntelligentDefrosting
“Turbo”function
€Wide
Voltage
FREE MATCH
W
TURBO
V
Auto-diagnosis
Low voltageStart-up
HI-WALL
X3I HL
CASSETTE
X3I AS
X3I SD
X3I FC
X3I AF
2400018000120009000Btu/h
DUCTED
CONSOLE
FLOOR-CEILING
DC INVERTER TECHNOLOGY
WIDE RANGE
LOW AMBIENT COOLING
SEVERAL MATCHINGS Possibility of choice among different types of indoor units, meeting any need
(105 Model)
Low Consumption
Low Noise Level
Precise temperature control
All models can work up to -15°C in cooling mode, except only for model 105 (-5°C)
Capacity range from 14 to 42000 BTU/h
Widely used in residential houses, hotel, business offices
www.argoclima.com
ENERGY CLASS
X3I 27 HL - X3I FC27HL - X3I AF27HL 9000
Btu/h INDOOR UNIT MODELS
X3I 35 HL - X3I AS35HL - X3I SD35HL X3I FC52HL - X3I AF35HL 12000
18000
24000
X3I 52 HL - X3I AS52HL - X3I SD52HLX3I FC52HL - X3I AF52HL X3I 64 HL
4
DUAL/TRIAL SPLIT
Type IU IU
OU X3MI 41SH 9000 90009000 12000
Type IU IU9000 9000
OU X3MI 52SH 9000 1200012000 12000
Type IU IU IU9000 90009000 120009000 18000
OU X3MI 61SH 12000 1200012000 180009000 9000 90009000 9000 1200012000 12000 12000
Type IU IU IU9000 90009000 120009000 1800012000 1200012000 18000
OU X3MI 71SH 18000 180009000 9000 90009000 9000 120009000 9000 180009000 12000 1200012000 12000 12000
QUADRI SPLIT
Type IU IU IU IU9000 90009000 120009000 1800012000 1200012000 1800018000 180009000 9000 90009000 9000 120009000 9000 180009000 12000 180009000 12000 1200012000 12000 180009000 12000 180009000 9000 1800012000 12000 120009000 9000 9000 90009000 9000 9000 120009000 9000 12000 12000
OU X3MI 80SH
Matchings
Controllers
INDOOR UNIT TYPES
CONTROLLERS
DUCTEDHI-WALL FLOOR/CEILINGCASSETTE CONSOLE
www.argoclima.com 5
PENTA SPLIT
Type IU IU IU IU IU
9000 120009000 180009000 2400012000 1200012000 1800012000 2400018000 1800018000 2400024000 240009000 9000 90009000 9000 120009000 9000 180009000 9000 240009000 12000 120009000 12000 180009000 12000 240009000 18000 180009000 18000 2400012000 12000 1200012000 12000 1800012000 12000 2400012000 18000 1800012000 18000 2400012000 24000 2400018000 18000 1800018000 18000 240009000 9000 9000 90009000 9000 9000 120009000 9000 9000 180009000 9000 9000 240009000 9000 12000 120009000 9000 12000 240009000 9000 18000 180009000 9000 18000 180009000 12000 12000 120009000 12000 12000 1800012000 12000 12000 1200012000 12000 12000 180009000 9000 9000 9000 90009000 9000 9000 9000 120009000 9000 9000 9000 180009000 9000 9000 12000 120009000 9000 12000 12000 12000
OU X3MI 120SH
Type IU IU IU IU9000 90009000 120009000 180009000 2400012000 1200012000 1800012000 2400018000 1800018000 2400024000 240009000 9000 90009000 9000 120009000 9000 180009000 9000 240009000 12000 120009000 12000 180009000 12000 240009000 18000 180009000 18000 2400012000 12000 1200012000 12000 1800012000 12000 2400012000 18000 1800012000 18000 240009000 9000 9000 90009000 9000 9000 120009000 9000 9000 180009000 9000 9000 240009000 9000 12000 120009000 9000 12000 180009000 9000 18000 180009000 12000 12000 120009000 12000 12000 1800012000 12000 12000 12000
X3MI 105SHOU
QUADRI SPLIT
Matchings
www.argoclima.com6
Technical data - Outdoor units
OUTDOOR MODEL - DUAL SPLIT X3MI 41SH X3MI 52SHUnits Cooling Heating Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 4,1 (2,05-4,40) 4,4 (2,49-5,42) 5,2 (2,14-5,84) 5,4 (2,58-5,51)BTU/h 14000 15000 17750 18430
EER/COP (EN14511) 3,42 3,73 3,59 3,48Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 4,1 3,8 5,2 5,0
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 6,3 4,0
Energy efficiency class A++ A+ A++ A+Annual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 235 1330 288 1750
Numero minimo-max unità interne collegabili no. 2 2Air flowrate m³/h 2600 3200Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 55 56Sound power Outdoor (h.) dB(A) 62 62Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,2 1,18 1,45 1,55Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 1,4/2,92 1,6/3,34Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-10 3-10Max. pipe lenght with additional charge m 20 20Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 5 5Max. height between units (Indoor on top) m 5 5Net dimension Outdoor (H./W./D.) mm 596x899x378 700x955x396Net weight Kg 43 51
OUTDOOR MODEL - TRIAL SPLIT X3MI 61SH X3MI 71SHUnits Cooling Heating Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 6,1 (2,2-7,33) 6,5 (3,61-8,5) 7,1(2,29-8,5) 8,5 (3,66-8,79)BTU/h 20820 22180 24230 29000
EER/COP (EN14511) 3,19 3,76 3,26 3,73Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 6,1 5,8 7,1 7,0
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 6,1 4,0
Energy efficiency class A++ A+ A++ A+Annual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 350 2030 407 2450
Numero minimo-max unità interne collegabili no. 2-3 2-3Air flowrate m³/h 3200 4000Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 56 58Sound power Outdoor (h.) dB(A) 65 65Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,91 1,73 2,18 2,28Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 2,2/4,59 2,2/4,59Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-30 3-30Max. pipe lenght with additional charge m 60 60Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Outdoor (H./W./D.) mm 700x955x396 790x980x427Net weight Kg 62 68
Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.
OPERATING RANGE mod. 41-52-61-71 (outdoor temperature)Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C
www.argoclima.com 7
Technical data - Outdoor units
www.argoclima.com
OUTDOOR MODEL - QUADRI SPLIT X3MI 80SH X3MI 105SHUnits Cooling Heating Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 8,0 (2,29-10,26) 9,30 (3,66-10,26) 10,5 (2,1-11) 11(2,6-13)BTU/h 27300 31730 35830 37530
EER/COP (EN14511) 3,23 3,71 3,00 2,93Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 8,0 7,0 10,5 10,5
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 5,50 3,80
Energy efficiency class A++ A+ A+ AAnnual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 459 2450 668 3876
Numero minimo-max unità interne collegabili no. 2-4 2-4Air flowrate m³/h 4000 5200Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 58 57Sound power Outdoor (h.) dB(A) 65 67Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 2,54 2,49 3,50 3,75Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 2,4/5,01 4,3/8,98Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-40 3-40Max. pipe lenght with additional charge m 70 70Additional refrigerant charge g/m 20 22Max. height between units (Outdoor on top) m 10 15Max. height between units (Indoor on top) m 10 15Net dimension Outdoor (H./W./D.) mm 790x980x427 1103x1015x440Net weight Kg 69 94
OUTDOOR MODEL - PENTA SPLIT X3MI 120SH Units Cooling Heating
Capacity (nominal-min.-max.) (EN14511) kW 12,1 (2,1-13,6 13 (2,6-14)BTU/h 41300 44360
EER/COP (EN14511) 3,37 3,66Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW nd>12kW nd>12kW
Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) nd>12kW nd>12kW
Energy efficiency class nd>12kW nd>12kWAnnual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum nd>12kW nd>12kW
Numero minimo-max unità interne collegabili no. 2-5Air flowrate m³/h 5500Fan speeds Outdoor n° 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 54Sound power Outdoor (h.) dB(A) 64Power supply V/Ph/Hz 230/1/50Power input kW 3,59 3,55Compressor type Rotary DC InverterRefrigerant type R410ARefrigerant charge kg/T.CO2 eq. 4,8/10,02Liquid pipe diameter mm (") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-40Max. pipe lenght with additional charge m 70Additional refrigerant charge g/m 22Max. height between units (Outdoor on top) m 15Max. height between units (Indoor on top) m 15Net dimension Outdoor (H./W./D.) mm 1103x1015x440Net weight Kg 102
Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.
OPERATING RANGE mod. 80 (outdoor temperature) OPERATING RANGE mod. 105/120 (outdoor temperature)Cooling mode: from -5°C to +48°CHeating mode: from -15°C to +24°CTemperature setting range: 16-30°C
Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C
8
Technical data - Indoor units
HI-WALL INDOOR UNITS X3I 27 HL X3I 35 HL X3I 52 HL X3I 64 HL Units Cooling Heating Cooling Heating Cooling Heating Cooling Heating
Capacity kW 2,6 2,8 3,5 3,7 5,13 5,28 6,7 7,25Air flowrate m³/h 560-490-430-330 660-540-460-330 800-720-610-520 1150-1050-950-850Dehumidification l/h 0,8 1,4 1,8 2,4Fan speeds n° 4 4 4 4Sound pressure (sh.-h.-m.-l.) dB(A) 39-36-32-26 42-39-33-26 46-42-39-36 48-45-42-39Sound power U.I. (sh.-h.-m.-l.) dB(A) 53-49-45-39 57-53-45-42 58-54-51-48 64-59-56-53Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7(1/2") 15,88 (5/8")Net dimension (H./W./D.) mm 275/790/200 289/845/209 300/970/224 325/1078/246Net weight kg 9 10 13,5 17
CASSETTE INDOOR UNITS X3I AS35HL X3I AS52HL Units Cooling Heating Cooling Heating
Capacity kW 3,5 4,0 4,5 5,0Air flowrate m³/h 600 600Dehumidification l/h 1,4 1,8Fan speeds n° 3+auto 3+autoSound pressure (sh.-h.-m.-l.) dB(A) 46-44-42 46-44-42Sound power U.I. (sh.-h.-m.-l.) dB(A) 56-54-52 56-54-52Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 12,7 (1/2")Unit net dimension without panel (H./W./D.) mm 230/570/570 230/570/570
Panel net dimension (H./W./D.) mm 50/650/650 50/650/650Unit net weight without panel kg 18 18Panel net weight kg 2,5 2,5
DUCTED INDOOR UNITS X3I SD27HL X3I SD35HL X3I SD52HL Units Cooling Heating Cooling Heating Cooling Heating
Capacity kW 2,50 2,80 3,5 3,85 5,0 5,5Air flowrate m³/h 450 500 700Static pressure min-max Pa 0-10 0-10 0-10Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 3+auto 3+auto 3+autoSound pressure (sh.-h.-m.-l.) dB(A) 37-34-31 39-35-32 41-36-33Sound power U.I. (sh.-h.-m.-l.) dB(A) 47-44-41 49-45-42 50-46-43Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 200/700/615 200/700/615 200/900/615Net weight kg 22 23 27
FLOOR/CEILING INDOOR UNITS X3I FC27HL X3I FC35HL X3 FC52HL Units Cooling Heating Cooling Heating Cooling Heating
Capacity kW 2,5 2,8 3,5 3,85 5,0 5,5Air flowrate m³/h 650-550-450 650-550-450 950-700-500
Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 7 7 7Sound pressure (sh.-h.-m.-l.) dB(A) 40-38-36 40-38-36 45-42-40Sound power U.I. (sh.-h.-m.-l.) dB(A) 50-48-46 50-48-46 55-52-50Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 225/1220/700 225/1220/700 225/1220/700Net weight kg 40 40 40
CONSOLE INDOOR UNITS X3I AF27HL X3I AF35HL X3I AF52HLUnits Cooling Heating Cooling Heating Cooling Heating
Capacity kW 2,5 2,8 3,5 3,85 5,3 5,8Air flowrate m³/h 500-430-410-370-330-280-250 600-520-480-440-400-360-280 650-620-550-500-450-410-320
Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 7 7 7Sound pressure (sh.-h.-m.-l.) dB(A) 40-38-36-33-30-27-25 42-40-38-37-35-32-27 48-46-44-41-37-35-32Sound power U.I. (sh.-h.-m.-l.) dB(A) 55-53-51-48-45-42-40 57-55-53-52-50-47-42 62-59-57-55-52-50-47Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 600/700/215 600/700/215 600/700/215Net weight kg 15 15 15
www.argoclima.com 9
Head officeVia Alfeno Varo, 3525020 Alfianello (BS) ITALYTel: + 39 0331 755111Fax: + 39 0331 775501www.argoclima.com
www.argoc l ima .com
7020
1700
3 - 0
3/20
17
N.B. The manufacturer assumes no responsability for any errors or inaccuracies regarding the contents of this catalogue, and reserves the right to make any necessary changes to its products, at any time and without prior notice, for technical or commercial reasons.
Argo is a brand of , a leading European company in Air Conditioning, Heating and Air Treatment.