Application Note
Mobile Backhaul Measurement Solutions
MS2830A Signal Analyzer
Slide 1
MS2830A-E-F-4
ANRITSU CORPORATION
MS2830A Signal Analyzer series Application Note
MS2830A-044 26.5GHz Signal Analyzer MS2830A-045 43GHz Signal Analyzer
Mobile Backhaul MeasurementSolutions
Version 1.00
MS2830A-044: 9kHz to 26.5GHz MS2830A-045: 9kHz to 43.0GHz
Slide 2
MS2830A-E-F-4
Anritsu T&M Solution
RRH
RR
H
BTS
AntennaAntenna Mobile BackhaulMobile Backhaul Mobile CoreMobile Core
MT9090A Optical Channel Analyzer
CWDM Test
CMA5kaTDM/Ethernet
NW Performance Test
OLTONU
MD1230B Ethernet over PON
Ethernet/PON Test
RNC
SGSN
GGSN
Internet
MGW
MSC
TDM (SDH/SONET)
Carrier Class Ethernet
MD1230B Ethernet tester
NW Device Performance Test
MP1590B TDM/Ethernet/Jitter
MT9090A Ethernet
Ethernet Test
MT9090AOTDR
Optical Test
Optical Fiber TestMT9083/MT9090AOTDR
Ethernet TestMT9090A Ethernet
BTS
CMA 3000 TDM/Ethernet
NW Performance Test
MT8221B RF spectrum / Error
RF Test
TDM
Ethernet
RF over Copper
RF over Fiber
Install/Maint.R&D/Manuf.
MS2726C
Spectrum Master
Spectrum Test
Signal Analyzer
RF Test
MG3700AVecto
r SG
Component TestMS464xA
VNAMG3690 Microwave SG
Microwave link
Anritsu is a total solution provider!
MS20xx
VNA Master
Cable Test
Slide 3
MS2830A-E-F-4
Microwave Link Measurement Solution(R&D/Manufacturing)
Anritsu offers both wired and wireless measuring instruments for
evaluating Microwave link devices, modules, and equipment.
Signal Generator Network Analyzer Ethernet TesterSignal Analyzer
(1) ODU Evaluation(2) ODU Device/Module Evaluation(3) IDU Evaluation(4) System Evaluation
Microwave Link Measurement Solutions
Slide 4
MS2830A-E-F-4
ODU
MG3690C Microwave Signal Generator
+ MG3700A Vector Signal Generator
Wanted Waveform
IF
Microwave Link Measurement Solution (R&D/Manufacturing) (1) ODU Evaluation
MG3700A
Vector Signal Generator
MS269x/2830A
Signal Analyzer
Tx Test
•
Up to 6 GHz using IF signal source
•
PSK/QAM signal output using waveform generation software
•
43 GHz max.
(With external mixer: 110GHz)
•
High-speed power/spectrum measurements
•
Modulation quality test using vector modulation analysis software
RF
Rx Test
•
70 GHz max.
•
PSK/QAM signal output using waveform generation software
MS269x/2830A
Signal Analyzer
IF
The Tx
and Rx performance of ODU equipment can be evaluated using a signal analyzer and signal generator supporting high frequency bands.
Measurements• Frequency Error• Max Power• Spectrum Mask• Spurious • Tx
EVM
Measurements• Rx EVM•
NF (under consideration )
•
High-speed power/spectrum measurements
•
Modulation quality test using vector modulation analysis software
Slide 5
MS2830A-E-F-4
Microwave Link Measurement Solution (R&D/Manufacturing) (2) ODU Device/Module Evaluation
•
Wide frequency setting range from 70 kHz to 70 GHz
•
Supports 0.1 Hz to 70 GHz
•
Frequency expansion to 335 GHz using waveguide
•
Reduced degraded EVM when using as LO signal source with low phase noise option
ODU devices and modules can be evaluated using network analyzers
and signal generators supporting high frequencies.
Measurement Targets•
Passive Components•
Filters/Duplexers•
Power Dividers/Combiners
•
Active Components•
Power Amps•
Low-noise Amps
•
Frequency Converters•
Antennas
Applications•
LO Signal Replacement•
Interference Waves
•
Wide frequency setting range from 70 kHz to 110 GHz
•
Supports up to 500 GHz as waveguide solution
MG369xC Microwave Signal Generator
ME7828A
Wideband Milliwave
Network Analysis System
MS464xA Vector Network Analyzer
Slide 6
MS2830A-E-F-4
IF Tests
IF
Network Tests
•
IF signal generation up to 6 GHz
•
PSK/QAM signal output using waveform generation software
•
Rx sensitivity test
IDU
MG3700A
Vector Signal Generator
or
IF
Ethernet Tester
Microwave Link Measurement Solution (R&D/Manufacturing) (3) IDU Evaluation
• Loop-back BER test
IDU evaluations can be performed using signal analyzers, signal generators and Ethernet testers covering the IF band.
Measurements•
Tx
power, power control• Tx
EVM (IF)• BER (IDU internal)
Measurements• BER (SDH)
IF
MS269x/2830
Signal Analyzer
(with VSG option)
•
High-speed power/spectrum measurements
•
Modulation quality test using vector modulation analysis software
Slide 7
MS2830A-E-F-4
Easy wireless section troubleshooting using seamless signal capture function
ODU
IDUIDUEthernet Tester
General network quality can be evaluated by BER tests using an Ethernet tester. The signal analyzer seamless capture function makes it easy to troubleshoot wireless
sections.
MS269x/2830
Signal Analyzer
MS269x/2830
Signal Analyzer IQ DataIQ Data
General network quality evaluation using BER
ODU
Microwave Link Measurement Solution (R&D/Manufacturing) (4) System Evaluation
Slide 8
MS2830A-E-F-4
Anritsu offers compact measuring instruments for spectrum, cable
and Ethernet evaluations used at Microwave link installation and maintenance.
(1) Optical Cable, Ethernet Tester(2) Spectrum, Cable Tester
Microwave Link Measurement Solutions (Installation and Maintenance)
Microwave Link Measurement Solutions
Network Analyzer Spectrum Analyzer
Ethernet TesterOptical Cable Tester
Slide 9
MS2830A-E-F-4
Compact Field SolutionsMT9090A Network Master Series
Microwave Link Measurement Solutions (Installation and Maintenance) Optical Cable and Ethernet Tests
Gigabit Ethernet (optical fiber)
Antenna
RF (optical fiber)
MT9090AOTDR Module
Optical Fiber Tests
MT9090AGigabit Ethernet Module
Ethernet Tests
•
IP/Ethernet performance tests
(throughput, jitter, delay, etc.)
• Connection tests (ping, trace route)• Live traffic analysis
•
Dual 1310/1550 nm wavelength support• 37 dB max. dynamic range• All PON tests
BTS
RRH
• Compact (190 x 96 x 48 mm)• Lightweight (700 g max.) • Battery powered• Easy field portability• One-key operation
Slide 10
MS2830A-E-F-4
MS20xxB and MS20xxC
Vector Network Master
•
Locate loss point and time/distance analyses
•
Locate loss points between IDU and ODU
MS2726C
Spectrum Master
•
Signal strength
•
Occupied bandwidth
Microwave Link Measurement Solutions (Installation and Maintenance) Spectrum and Cable Tests
ODU
IDU
Spectrum and cable measurements are supported by compact spectrum and network analyzers.
Slide 11
MS2830A-E-F-4
MS2830A Signal Analyzer series Features
MS2830A-044: 9kHz to 26.5GHz MS2830A-045: 9kHz to 43.0GHz
Slide 12
MS2830A-E-F-4
26.5/43 GHz Signal Analyzer FeaturesPerformance
Measures up to 110 GHz with external mixerSupports use as down-converter
Connector: SMA-J, 50 ΩIF output frequency: 1875 MHzIF output bandwidth: 1 GHz (3-dB bandwidth) nominal
Wide Dynamic Range (< 13.5 GHz)159 dB (26.5 GHz)
DANL: –146
dBm/Hz*1
(18.3 < f < 34 GHz)
TOI: +13
dBm*2
(6 GHz < f < 26.5 GHz)Dynamic range: Difference between TOI and DANL as simple guide. DANL: Displayed Average Noise LevelTOI: Third-order intermodulation distortion
Preamp up to 43 GHzDANL: –156
dBm/Hz*3
(18.3 < f < 34 GHz)
*1: Without Opt-067/068. *2: Without Opt-068 or preamp OFF. *3: Without Opt-067 or Preselector
Bypass OFF, and with Opt-068 and preamp ON. *4: With Opt-068 and preamp ON, and with Opt-067 and Preselector
Bypass OFF. *5: Without Opt-068 or preamp ON. Attenuator = 10 dB to 60 dB *6: MS2830A-044/045 only. Excludes other options. *7: With Opt-067 or Opt-007
MS2830A-044: 9 kHz to 26.5 GHz
MS2830A-045: 9 kHz to 43.0 GHz
Function31.25 MHz analysis bandwidthsupporting up to 43 GHz*7
<Modulation Analysis> <Signal Analyzer>
Low costLow power consumption for saving costs!
190 VA nominal*6
*: The MS2830A-007 is not sold in some areas. Please contact us.
Slide 13
MS2830A-E-F-4
Performance: Measures Up to 110 GHz with External Mixer
Standard local output (LO) for external mixer!
Combination with an external mixer supports spectrum measurements up to 110 GHz.This supports high-sensitivity measurements with local signal outputs at high frequencies from 5 to 10 GHz to minimize the
required LO harmonic order.
MS2830A-044/045
SMA Cable
DUT
1st
Local Output■
Connector: SMA-J, 50 Ω
(nominal)■
Local Signal Output: 5 GHz to 10 GHz■
IF Signal Frequency: 1875 MHz■
Local Signal Level: ≥
+10 dBm
(typ.)
Slide 14
MS2830A-E-F-4
Performance: Use as Wideband Down-Converter
Harmonic mixing internal band and IF signals from
the external mixer can be output from the back-panel IF Output
connector. Because
the IF frequency is
1.875 GHz, this can be used as a down-
converter for millimeter-wave wideband modulation signal analysis, such as the 1-GHz modulation bandwidth.
MS2830A
Center frequency80 GHz
Bandwidth 1 GHz
1.875 GHz
1 GHz band
Down-convert(example 80 GHz → 1.875 GHz)
IF Output:
1.875 GHz
DUT Back Panel
Oscilloscope
IF output frequency 1.875 GHz, IF bandwidth 1 GHz nominal
Measurement image: Down-convert signals with 80 GHz center frequency and 1 GHz bandwidth to 1.875 GHz
Slide 15
MS2830A-E-F-4
Performance: Built-in Versatile Measurement Functions
Measures FSK and GMSK modulation wave frequency variation, and VCO frequency switching time
Frequency vs. Time
Spectrum Power vs. Time
Supports wideband CCDF analysis up to 125 MHz; useful for evaluating power amplifiers in wideband communications systems
Displays waveform of wideband SPAN up to 125 MHz without interruption
Supports wideband CCDF analysis up to 31.25 MHz and ideal for evaluating power amps for wideband communication systems
CCDF/APD
SpectrogramDisplays spectrum variations with time; useful for understanding waveform transients because supports visual monitoring of frequency and level time variations
Frequency
Power Time
Phase vs. TimeMonitors time fluctuations of phase to check sudden phase shift
Installing the 10 MHz/31.25 MHz Analysis Bandwidth (Opt. 005/006/007) supports signal analyzer measurement functions in the above frequency range. The instantaneous frequency change , phase change and expanse of the spectrum are captured by various functions of the signal analyzer. The instantaneous change of the RF signal of the microband
which the spectrum analyzer of the sweep type cannot catch is confirmed. This function supports inspection of the initial development.
Slide 16
MS2830A-E-F-4
Performance: Supports 31.25 and 43 GHz Analysis Bandwidth
MX269017A Vector Modulation Analysis Software■
Modulation methodBPSK, QPSK, Pai/4 DQPSK, 8PSK, 16QAM, 64QAM, 2FSK, 4FSK
256QAM *1
■
FilterNyquist/Root Nyquist/Non
■
Symbol rate (Upper limit depends on analysis bandwidth 10 MHz/31.25 MHz)
0.1 k to 2.5 M/6.25 M symbol/s*2
0.1 k to 5 M/12.5 M symbol/s*3
0.1 k to 5 M/35 M symbol/s*4
Wideband analysis with high frequencies is supported for microwave links.Modulation analysis and various VSA functions improve design verification efficiency.
MS2830A-067 Microwave Preselector Bypass supports 31.25-MHz wideband measurements up to 43 GHz
*1: 256QAM available with Non-Format
*2: When 2FSK and 4FSK
*3: When Frame Formatted and xxPSK, xxQAM
*4: When Non-Formatted and xxPSK, xxQAM
Slide 17
MS2830A-E-F-4
Performance: World No.1 Dynamic range
MS2830A-045(43GHz) TOI-DANLwith preamplifier, without preselector bypass
-160
-150
-140
-130
-120
-110
-100
-90
-80
0 10 20 30 40
Frequency [GHz]
DAN
L [d
Bm/H
z]
Wide C/N measurement for Spurious, Mask and Occupied Bandwidth tests
Dynamic range is a key specification for spectrum analyzers. Low
displayed average noise level (DANL) as well as third-
order intermodulation
distortion (TOI) are important too. Sometimes, distortion may occur in the mixer when inputting a carrier signal with low TOI and high level. In this case, the input level to the mixer can be reduced using an attenuator but, at the same time, the level of fine spurious also drops, making it impossible to find the noise floor. The MS2830xA has an excellent dynamic range, supporting accurate measurements
for checking
the spectrum, such as spurious tests, mask and occupied bandwidth with wide dynamic range.
+15
+14
+13
+12 TOI [
dBm
]
Wide Dynamic RangeWide Dynamic Range
Slide 18
MS2830A-E-F-4
Performance: Wide Dynamic RangeExcellent performance with >6 GHz! For spurious tests!
The basic configuration for DANL with >6 GHz supports best-of-class performance. The above performance is assured without preamp option.
Hig
h pe
rfor
man
ce
26.5 GHz model price image
DANL comparisonwithout Preamplifier and Preselector Bypass
-160
-155
-150
-145
-140
-135
-130
-125
-120
0 10 20 30 40
Frequency [GHz]
DA
NL
[dBm
/Hz]
Product A (26GHz)
Product B (26GHz)
Product C (43GHz)
Product D (50GHz)
Product E (40GHz)
Product F (40GHz)
MS2830A(43G)
Slide 19
MS2830A-E-F-4
MS2830A Signal Analyzer series ETSI Standard Measurements
MS2830A-044: 9kHz to 26.5GHz MS2830A-045: 9kHz to 43.0GHz
Slide 20
MS2830A-E-F-4
ETSI Standard Measurements (1/9)ETSI standard measurements can be done simply and efficiently by
the MS2830A excellent dynamic range performance and extensive measurement functions.
OBW Limit line Spurious VSA
Slide 21
MS2830A-E-F-4
ETSI Standard Measurements (2/9)
Power MeterDUT
(Microwave link) ATT
5.2.1 Transmitter power range5.2.3 Transmitter power tolerance
5.2.2.1.1 Automatic Transmit Power Control (ATPC)Output at Max power
Power MeterDUT
(Microwave link) ATT
Output at ATPC mode
Max power measurement
5.2.2.1.1 Remote Transmit Power Control (RTPC)Power Meter
DUT(Microwave link) ATT
Output at PTCP mode
Max/Min power measurement
Max/Min power measurement
Slide 22
MS2830A-E-F-4
ETSI Standard Measurements (3/9)
MS2830A
DUT(Microwave link) ATT
5.2.2.2 Remote Frequency Control (RFC) 5.2.8 Radio frequency tolerance
Frequency Measurement
Frequency measurement during modulation using OBW function
Slide 23
MS2830A-E-F-4
ETSI Standard Measurements (4/9)
MS2830A
DUT(Microwave link) ATT
5.2.4 RF Spectrum Mask (1/2)
Output at each frequency, bandwidth and modulation method
Judge measurement with Limit Line function
•
Easy mask measurement using Limit Line function
•
Optional Mask Test of -60 dB at 38 GHz can be done with enough margin by MS2830A excellent dynamic range
Slide 24
MS2830A-E-F-4
ETSI Standard Measurements (5/9)
MS2830A
DUT(Microwave link) ATT
5.2.4 RF Spectrum Mask (2/2)
Output at each frequency, bandwidth and modulation method
Measurement with Limit Line function
Templates are swelling in number due to the different mask templates for each output frequency, bandwidth, and modulation method.Using the MS2830A Limit Line editing function and flexible Save/Recall function makes Mask tests easy and fast.
Slide 25
MS2830A-E-F-4
ETSI Standard Measurements (6/9)
MS2830ADUT
(Microwave link) ATT
5.2.5 Discrete CW components exceeding spectrum mask limits
Output at each frequency, bandwidth and modulation method
Measure CW components exceedingLimit Line with Mask function
•
Up to 10 separate markers can be set with the Multi-Marker function.
•
Even frequency with randomness can be easily measured using the Zone Marker function to display peak values within a specifiable setting range.
Slide 26
MS2830A-E-F-4
ETSI Standard Measurements (7/9)
MS2830A
DUT(Microwave link) ATT
5.2.6 Spurious emissions-external
Output at Max power Spurious measurementwith Spurious function
•
Up to 20 segments
can be measured at high speed using the Spurious function.
•
With the excellent Dynamic Range performance, the MS2830A reduces the number of required filters and amps to support a simple, low-cost test solution.
BRF
Slide 27
MS2830A-E-F-4
ETSI Standard Measurements (8/9)
MS2830ADUT
(Microwave link)
5.2.7 Dynamic Change of Modulation Order (1/2)
Output at each modulation method
•
The presence/absence of quality deterioration can be easily identified using the Limit Line function in the Max Hold mode.
•
The VSA function explained on the next slide is useful for investigating the deterioration timing.
ATTMeasurement with Limit Line function in Max Hold status
Slide 28
MS2830A-E-F-4
ETSI Standard Measurements (9/9)
MS2830ADUT
(Microwave link)
5.2.7 Dynamic Change of Modulation Order (2/2)
Output at each modulation method
The timing of signal deterioration can be found easily using the VSA to seamlessly capture signals.
(Example: degraded waveform quality when switching from 16QAM to 256QAM, etc.)
ATTMeasure with VSA function
56 MHz band
31.25MHz VSA
Momentary distortion
Anritsu Corporation 5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 JapanPhone: +81-46-223-1111Fax: +81-46-296-1238
• U.S.A.Anritsu Company1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A.Toll Free: 1-800-267-4878Phone: +1-972-644-1777Fax: +1-972-671-1877
• CanadaAnritsu Electronics Ltd.700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, CanadaPhone: +1-613-591-2003 Fax: +1-613-591-1006
• Brazil Anritsu Eletrônica Ltda.Praça Amadeu Amaral, 27 - 1 Andar01327-010 - Bela Vista - São Paulo - SP - BrazilPhone: +55-11-3283-2511Fax: +55-11-3288-6940
• MexicoAnritsu Company, S.A. de C.V.Av. Ejército Nacional No. 579 Piso 9, Col. Granada11520 México, D.F., MéxicoPhone: +52-55-1101-2370Fax: +52-55-5254-3147
• U.K.Anritsu EMEA Ltd.200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.Phone: +44-1582-433200 Fax: +44-1582-731303
• FranceAnritsu S.A.12 avenue du Québec, Bâtiment Iris 1- Silic 612,91140 VILLEBON SUR YVETTE, FrancePhone: +33-1-60-92-15-50Fax: +33-1-64-46-10-65
• GermanyAnritsu GmbHNemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
• ItalyAnritsu S.r.l.Via Elio Vittorini 129, 00144 Roma, ItalyPhone: +39-6-509-9711 Fax: +39-6-502-2425
• SwedenAnritsu ABBorgarfjordsgatan 13A, 164 40 KISTA, SwedenPhone: +46-8-534-707-00 Fax: +46-8-534-707-30
• FinlandAnritsu ABTeknobulevardi 3-5, FI-01530 VANTAA, FinlandPhone: +358-20-741-8100Fax: +358-20-741-8111
• DenmarkAnritsu A/S (Service Assurance)Anritsu AB (Test & Measurement)Kay Fiskers Plads 9, 2300 Copenhagen S, DenmarkPhone: +45-7211-2200Fax: +45-7211-2210
• RussiaAnritsu EMEA Ltd. Representation Office in RussiaTverskaya str. 16/2, bld. 1, 7th floor.Russia, 125009, MoscowPhone: +7-495-363-1694Fax: +7-495-935-8962
• United Arab EmiratesAnritsu EMEA Ltd.Dubai Liaison OfficeP O Box 500413 - Dubai Internet CityAl Thuraya Building, Tower 1, Suit 701, 7th FloorDubai, United Arab EmiratesPhone: +971-4-3670352Fax: +971-4-3688460
• SingaporeAnritsu Pte. Ltd.60 Alexandra Terrace, #02-08, The Comtech (Lobby A)Singapore 118502Phone: +65-6282-2400Fax: +65-6282-2533
• IndiaAnritsu Pte. Ltd. India Branch Office3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, IndiaPhone: +91-80-4058-1300Fax: +91-80-4058-1301
• P.R. China (Hong Kong)Anritsu Company Ltd.Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong KongPhone: +852-2301-4980Fax: +852-2301-3545
• P.R. China (Beijing)Anritsu Company Ltd.Beijing Representative OfficeRoom 2008, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. ChinaPhone: +86-10-6590-9230Fax: +86-10-6590-9235
• KoreaAnritsu Corporation, Ltd.8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, KoreaPhone: +82-2-553-6603Fax: +82-2-553-6604
• AustraliaAnritsu Pty. Ltd.Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, AustraliaPhone: +61-3-9558-8177Fax: +61-3-9558-8255
• TaiwanAnritsu Company Inc.7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, TaiwanPhone: +886-2-8751-1816Fax: +886-2-8751-1817
Specifications are subject to change without notice.
1103
Printed on Recycled Paper
Please Contact: