+ All Categories
Home > Documents > Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Date post: 13-Jan-2016
Category:
Upload: haley
View: 28 times
Download: 1 times
Share this document with a friend
Description:
Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage. G. Hobler, G. Otto, D. Kovac L. Palmetshofer 1 , K. Mayerhofer², K. Piplits² 1 Inst. Semiconductor and Solid State Physics, Univ. Linz ² Inst. Chem. Technol. and Analytics, TU Vienna. - PowerPoint PPT Presentation
Popular Tags:
25
Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage G. Hobler, G. Otto, D. Kovac L. Palmetshofer 1 , K. Mayerhofer², K. Piplits² 1 Inst. Semiconductor and Solid State Physics, Univ. Linz ² Inst. Chem. Technol. and Analytics, TU Vienna Institute of Solid-State Electronics
Transcript
Page 1: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Multiscale Approach for the Analysis of Channeling Profile

Measurements of Ion Implantation Damage

G. Hobler, G. Otto, D. KovacL. Palmetshofer1,

K. Mayerhofer², K. Piplits²1 Inst. Semiconductor and Solid State Physics, Univ. Linz

² Inst. Chem. Technol. and Analytics, TU Vienna

Institute of Solid-State Electronics

Page 2: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Damage Models in BC Simulations

• Traditional model:– defect positions: generated statistically

– atom positions: random interstitial model

– dynamic annealing: „recombination factor“

• Proposed model:– defect positions: trace each defect during the whole

simulation

– atom positions: take from ab-initio simulations

– dynamic annealing: kinetic lattice Monte Carlo simulation (kLMC) after each collision cascade

Page 3: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Overview

• Introduction

• BC-kLMC approach

• Application to channeling profile measurement (CPM) experiments

Page 4: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Damage Measurements

RBS

Channelingprofile

Page 5: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Channeling Implantations

• Fit dose dependence of channeling implantation profiles recombination factor

frec=0.125 Nsat=41021cm-2

(G.Hobler et al., J. Vac. Sci. Technol B14 (1) 272, 1996)

Page 6: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Channeling Profile Measurements

• Measure pre-existing crystal damage with a low-dose channeling implant

(M. Giles et al., MRS Symp. Proc. 469, 253, 1997)

Page 7: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

The Role of Dynamic Annealing in Si

• Temperature dependence of implant damage:

(J.E. Westmoreland et al., Appl. Phys. Lett. 15, 308, 1969)

Page 8: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

The Role of Dynamic Annealing in Si

• Dose-rate dependence of implant damage:

T=300K

(O.W. Holland et al., Rad. Eff. 90, 127, 1985)

70µA/cm²

0.14µA/cm²

Page 9: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Overview

• Introduction

• BC-kLMC approach

• Application to channeling profile measurement (CPM) experiments

Page 10: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Coupled BC-kLMC Approach

• Traditional approach:

• BUT: type and amount of defects influence BC trajectories (dechanneling)

kLMC

BCloopover

cascades

1 cascade

pointdefects

point defects + clusters

Page 11: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Coupled BC-kLMC Approach

• Proposed new approach:

kLMC

BCloopover

cascades old defects + new point defects

point defects + clusters

atom positionsfor each defect

defects

Page 12: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Details of kLMC

• Each defect is associated with one or more lattice sites

• Defects: Vn, In (n=1,2,3,...)

• Events:– Diffusion hops (I, V)

– Reactions of defects located within capture radius

Vn+V Vn+1 Vn+I Vn-1 In+I In+1 In+V In-1

• Parameters:

– DV=310-13 cm²/s DI=6.3510-17 cm²/s

– (Capture radii)

Page 13: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Details of kLMC

• „Old“ defects: restricted to column(periodic boundaryconditions)

• „New“ defects: anywhere

• Interaction between „new“

and „old“ defects: Using periodicity of „old“ defects

Page 14: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Details of BC

• Read defects from kLMC (columnar domain)

• Use periodicity to generate defects around projectile

• Atom positions from ab-initio calculations (VASP)– defect structure

– strain around defect

• All defects composed of individual I and V (currently)

Page 15: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Overview

• Introduction

• BC-kLMC approach

• Application to channeling profile measurement (CPM) experiments

Page 16: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

CPM Experiments

• Damage implant: N, 30 keV, 31014 cm-², 10° tilt

• CPM implant: B, 30 keV, 1013 cm-2, 0° tilt

shield(110)-Si

Page 17: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

CPM Experiments

• Results:

Page 18: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

CPM Simulation Results

• Simulation results without strain:

Page 19: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

CPM Simulation Results

• Strain from vacancies:

Page 20: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

CPM Simulation Results

• Strain from interstitials:

Page 21: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

What is wrong?

• Defects: Vn, In (n=1,2,3,...)

• Events:– Diffusion hops (I, V)

– Reactions of defects located within capture radius

Vn+V Vn+1 Vn+I Vn-1 In+I In+1 In+V In-1

• Parameters:

– DV=310-13 cm²/s DI=6.3510-17 cm²/s

– (Capture radii)

• Lack of amorphous pockets?

Page 22: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

What is wrong?

• Defects: Vn, In (n=1,2,3,...)

• Events:– Diffusion hops (I, V)

– Reactions of defects located within capture radius

Vn+V Vn+1 Vn+I Vn-1 In+I In+1 In+V In-1

• Parameters:

– DV=310-13 cm²/s DI=6.3510-17 cm²/s

– (Capture radii)

• Lack of amorphous pockets? NO

• Approximate treatment of I-Clusters?

Page 23: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

What is wrong?

• I-Clusters:

• Similar study on RBS-C: Efficiency of I2, I3, I4 within 40% of split-110 interstitial

I I2 I3

I4a I4b

(G. Lulli et al., Phys. Rev. B69, 165216, 2004)

Page 24: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

What is wrong?

• Defects: Vn, In (n=1,2,3,...)

• Events:– Diffusion hops (I, V)

– Reactions of defects located within capture radius

Vn+V Vn+1 Vn+I Vn-1 In+I In+1 In+V In-1

• Parameters:

– DV=310-13 cm²/s DI=6.3510-17 cm²/s

– (Capture radii)

• Lack of amorphous pockets? NO

• Approximate treatment of I-Clusters? Probably not

• Attraction of I+Vn, V+In and/or Repulsion of I+In, V+Vn

Page 25: Multiscale Approach for the Analysis of Channeling Profile Measurements of Ion Implantation Damage

Conclusions

• New approach for implant damage simulations– coupled BC and kLMC

– atom positions from ab-initio

• Consistent simulation of both defect generation and analysis

• Simulations yield too much damage need to use– interaction radii to favor recombination and/or

– reaction barriers to impede clustering


Recommended