N2-BLAST, FPS-1750/3000, (TYPE 2), GENERAL ARRANGEMENT WITH (JV)VERTICAL COMPRESSOR AND REFRIGERATED AIR DRYER
TABLE OF CONTENTSSHEET # DESCRIPTION
1 TABLE OF CONTENTS2 GENERAL ARRANGEMENT3 GENERAL ARRANGEMENT WITH BYPASS
DRAWING ECR REV. DESCRIPTION DATE CHANGED BY APPROVED BY
REVISIONS
- - 2 UPDATED TITLE BLOCK AND TEXT FORMAT 7/22/2015 PJS JVN
- - 1 UPDATED COMPRESSOR MODEL 7/22/2015 PJS JVNSCALE:
DATE:
APPROVED:
REVISION:
GA-TYP2M-JV 2
PJS
1:18
DRAWN:
1 OF 3BNUMBER:
SIZE: SHEET:
DATE:
11/28/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
N2-BLAST, TYPE 2, GENERAL ARRANGEMENT WITH (JV) VERTICAL
COMPRESSOR AND REFRIGERATED AIR DRYER, TABLE OF CONTENTS
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
11/28/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
REFRIGERATED AIR DRYER
AIR COMPRESSOR
FILTERS ARE TO BE CHANGED ANNUALLYAIR MAINTENANCE DEVICE/S(AMD/S) (SUPPLIED BY OTHERS)
ALL TYPE 2 N2-BLAST MUST BEWALL MOUNTED. WALL MOUNTING
BRACKETS ARE INCLUDED WITH UNIT
28 GALLON NITROGEN STORAGE TANKPROVIDED WITH WALL BRACKETS AND STRAP
NITROGEN GENERATOR BYPASS(NORMALLY CLOSED)
AIR / NITROGEN SUPPLYTO FPS PIPING
110V / 60Hz / 1PHASE NITROGEN GENERATOR HAS A 1/2" CONDUITKNOCKOUT UNDERNEATH CABINETS PANEL FOR POWER SUPPLY TO ELECTRICALPANEL. REFER TO DRAWING ES-TYP2M FOR PROPER CONNECTIONS
SOUTH-TEK RECOMMENDS TO INSTALL 24" OF "1/2" ID FLEX TUBING RATED FOR 200 PSIG / 135 F (MINIMUM) TO REDUCE VIBRATION FROM COMPRESSOR TO HARD PIPING (OPTIONAL PART NUMBER "002-310")
1/4" NPT TANK DRAIN
3/8" OD DRAIN LINE
1/4" MNPT FILTER DRAIN CONNECTION
GENERAL NOTES:ALL COMPONENTS WITHIN THIS DRAWING ARE FOR (1)ILLUSTRATION PURPOSES ONLY. FOR MORE INFORMATION ABOUT THE COMPRESSOR, DRYER AND NITROGEN GENERATOR REFER TO DRAWINGS; DD-AC-CH, DD-RD-SC-10, AND DD-TYP2M-FPS RESPECTFULLY.REFER TO THE MANUFACTURER'S MANUAL FOR ANCHORING (2)REQUIREMENTS OF THE COMPRESSOR AND DRYER.ALL TYPE 2 NITROGEN GENERATORS MUST BE WALL MOUNTED.(3)ALL CONNECTIONS ARE 1/2" NPT F UNLESS OTHERWISE (4)SPECIFIED.ALL PLUMBING, FITTINGS, VALVES, AND HARDWARE BETWEEN (5)COMPONENTS ARE SUPPLIED BY OTHERS.AIR COMPRESSOR, DRYER AND STORAGE TANK MUST BE (6)INSTALLED ON A HARD FLAT SURFACE.
DRAWING ECR REV. DESCRIPTION DATE CHANGED BY APPROVED BY
REVISIONS
- - 2 UPDATED TITLE BLOCK AND TEXT FORMAT 7/22/2015 PJS JVN
- - 1 UPDATED COMPRESSOR MODEL 7/22/2015 PJS JVNSCALE:
DATE:
APPROVED:
REVISION:
GA-TYP2M-JV 2
PJS
1:14
DRAWN:
2 OF 3BNUMBER:
SIZE: SHEET:
DATE:
11/28/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
N2-BLAST, TYPE 2, GENERAL ARRANGEMENT WITH (JV) VERTICAL COMPRESSOR AND REFRIGERATED
AIR DRYER
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
11/28/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
Z
Refrigerated Air Dryer
South-Tek recommends to install 24" of"1/2" ID flex tubing rated for 200 PSIG / 135 F(minimum) to reduce vibration from compressorto hard piping (Optional Part Number "002-310")
Air Compressor
Filters are to be Changed Annually
Air Maintenance Device/s (AMD/s)(Supplied by Others)
All Type II N2-Blast must beWall Mounted. Wall Mounting
Brackets are included with Unit
100# Nitrogen Storage TankProvided with Wall Bracket w/ Strap
Air / Nitrogen Supplyto FPS Piping
110V / 60Hz / 1Phase Nitrogen Generator has a 1/2" ConduitKnockout underneath Cabinets Panel for Power Supply to ElectricalPanel. Refer to Drawing ES-TYP2M for Proper Connections
1/4" NPT Tank Drain
3/8" OD Drain Line
1/4" MNPTFilter Drain
Connections
Air Bypass Alarm Option
DETAIL ZSCALE 1 : 7
General Notes:1) All Components within this Drawing are for Illustration Purposes only. For more information about the Compressor, Dryer and Nitrogen Generator refer to Drawings; DD-AC-CH, DD-RD-SC-10, and DD-TYP2M-FPS respectfully.2) Refer to the Manufacturer's Manual for Anchoring Requirements of the Compressor and Dryer.3) All Type II Nitrogen Generators must be Wall Mounted.4) All Connections are 1/2" NPT F unless otherwise specified.5) All Plumbing, Fittings, Valves, and hardware between components are Supplied by Others.6) Air Compressor, Dryer and Storage Tank must be installed on a hard flat surface.
A
B
C
D
SCALE:
DATE:
APPROVED BY:
REVISION:
GA-TYP2M-JV-03 1
11/28/14
PJS
1:14
DRAWN BY: CHECKED BY:
FINISH:MATERIAL: WEIGHT:
3 of 3BNUMBER:
SIZE: SHEET:
DATE: DATE:
PROJECT NAME;South-Tek Systems
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS
THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES
TOLERANCES:A
B
C
D
12345678
2345678 1
Whole Number Dim's: 1One Place Decimal: .2Two Place Decimals: .02Three Place Decimals: .005Angular: .05
N2-Blast, Type II, General Arrangement with (JV) Vertical Compressor,
Refrigerated Air Dryer and Air Bypass
3
5
4
6
217
Z
32.7
42.3
7.7 11.8
Y
34.1
7.7
11
DETAIL YSCALE 1 : 4
1412 13 15 16
17
DETAIL ZSCALE 1 : 5
89
10
3.57
36.25
.50 16.00
(4X) .33
1
EXTERNAL COMPONENTSITEM # DESCRIPTION
1 1/4" NPT M x F MINI BALL VALVE2 1/2" NPT F x 1/4" NPT M REDUCER3 PARTICULATE FILTER / REGULATOR COMBO4 COALESCING FILTER5 ABSORBING FILTER6 WALL MOUNT BRACKET7 1/2" NPT F x 1/4" NPT M REDUCER8 POWER SUPPLY KNOCKOUT FOR 1/2" CONDUIT9 DRYER CONTACT KNOCKOUT FOR 1/2" CONDUIT10 BLASTOFF LED LIGHT , 24V11 SERIAL NUMBER LABEL12 POWER ON/OFF ROCKER SWITCH13 BLASTOFF ALARM KNOCKOUT FOR1/2" CONDUIT14 HOUR METER15 STANDBY LED LIGHT, 24V16 OPTIONAL AIR BYPASS LIGHT KNOCKOUT17 UL 508A OPEN INDUSTRIAL CONTROL PANEL LABEL
DESIGN DATA FOR N2-BLAST TYPE 2 SYSTEMSGENERATOR FPS-1750 FPS-3000 FPS-6000
PURITY 98%AIR REQUIREMENT 3.2 SCFM @ 125 PSI 6.0 SCFM @ 125 PSI 10.5 SCFM @ 125 PSIN2 OUT PRESSURE Up to 80 psiWEIGHT 80 LBS 81 LBS 82 LBSELECTRICAL 110V / 60Hz / 1PHASE, 8AMPS
(FRP-002) FILTER REPLACEMENT KITSTS PART # DESCRIPTION QTY
524-137 PARTICULATE FILTER ELEMENT 1524-138 COALESCING FILTER ELEMENT 1524-139 ABSORBING FILTER ELEMENT 1
DRAWING ECR# REV. DESCRIPTION DATE CHANGED BY APPROVED BYREVISIONS
- - 2 UPDATED TITLE BLOCK, ADDED BACK VIEW WITH MOUNTING PATTERN DIMS 7/22/2015 PJS JVN
- - 1 ADDED FRP KIT INFORMATION 6/3/2015 PJS JVN
SCALE:
DATE:
APPROVED:
REVISION:
DD-TYP2M-FPS 2
PJS
1:10
DRAWN:
1 OF 1BNUMBER:
SIZE: SHEET:
DATE:
11/28/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
N2-BLAST, TYPE 2, DESIGN DATA AND DIMENSIONS
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
11/28/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
12
27
AA
16
57
43.5
11.75 .56 TYP
60° TYP
120° TYP
SECTION A-ASCALE 1 : 8
AVAILABLE ELECTRICAL OPTIONS AND DESIGN DATACUSTOMER # ELECTRICAL MOTOR AIR FLOW WEIGHTSTS-NF-C-2-J 120V / 60Hz / 1PHASE, 10.6 AMPS
1 HP 3.8 SCFM @ 120 - 140 PSI 250 LBS
STS-NF-C-2-J 208V / 60Hz / 1PHASE, 4.3 AMPSSTS-NF-C-2-J 230V / 60Hz / 1PHASE, 5.3 AMPSSTS-NF-C-2-J 208V / 60Hz / 3PHASE, 3.5 AMPSSTS-NF-C-2-J 230V / 60Hz / 3PHASE, 3.6 AMPSSTS-NF-C-2-J 460V / 60Hz / 3PHASE, 1.8 AMPSSTS-NF-C-3-J 120V / 60Hz / 1PHASE, 18.4 AMPS
2 HP 7.6 SCFM @ 120 - 140 PSi 250 LBS
STS-NF-C-3-J 208V / 60Hz / 1PHASE, 10.2 AMPSSTS-NF-C-3-J 230V / 60Hz / 1PHASE, 9.2 AMPSSTS-NF-C-3-J 208V / 60Hz / 3PHASE, 6.2 AMPSSTS-NF-C-3-J 230V / 60Hz / 3PHASE, 6.2 AMPSSTS-NF-C-3-J 460V / 60Hz / 3PHASE, 301 AMPS
DRAWING ECR# REV. DESCRIPTION DATE CHANGED BY APPROVED BYREVISIONS
- - 3 UPDATED TITLE BLOCK AND TEXT FORMAT 7/22/2015 PJS JVN- - 2 UPDATED ELECTRICAL TABLE 6/2/2015 PJS JVN- - 1 UPDATED ELECTRICAL TABLE 2/13/2015 PJS JVN
SCALE:
DATE:
APPROVED:
REVISION:
DD-AC-JV 3
PJS
DNS
DRAWN:
1 OF 1BNUMBER:
SIZE: SHEET:
DATE:
12/02/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
(JV) VERTICAL COMPRESSOR DESIGN DATA AND DIMENSIONS
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
12/02/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
19.9
8.90
15.14 .59 .40 DRAIN TUBE
11.97
13.27
1.34 6.26
.87 POWER CORD GROMMET
6.02
.61
3/8" FNPT INPUT INSTALL FITTINGS KIT (2222-0122J) TO CONVERT TO 1/2" FNPT PORT
3/8" FNPT OUTPUT, INSTALL FITTINGS KIT (2222-0122J) TO CONVERT TO 1/2" FNPT PORT
1.07
13
1.42 6.06
2.07
NOTES:(1) FITTINGS KIT INCLUDES (2) 3/8" MNPT X 1/2" FNPT ADAPTERS.
AIR DRYER DESIGN DATAELECTRICAL 115V / 60Hz / 1PHASE, 11AMPSFLOW RATE 10 SCFMWEIGHT 40 LBS
DRAWING ECR# REV. DESCRIPTION DATE CHANGED BY APPROVED BY
REVISIONS
- - 2 UPDATED TITLE BLOCK, TEXT FORMAT, AND ADDED CONNECTION KIT PART NUMBER 7/22/2015 PJS JVN
- - 1 UPDATED TITLE BLOCK 6/2/2015 PJS JVN
ITEM # STS PART # DESCRIPTION QTY.1 2222-0319 RD-10 AIR DRYER 12 2222-0122J (SEE NOTE 1) RD-10 FITTINGS KIT 1
SCALE:
DATE:
APPROVED:
REVISION:
DD-RD-SC-10 2
PJS
1:8
DRAWN:
1 OF 1BNUMBER:
SIZE: SHEET:
DATE:
12/03/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
MODEL 10 REFRIGERATED AIR DRYER DESIGN DATA AND
DIMENSIONS
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
12/03/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
33
49.5
15.10
1
2
3
WRAP STRAP AROUND TANK AND USE THEPLASTIC CLIP TO SECURE THE TANK TO WALL
SCALE 1 : 4
A5
A5
A2 A3A4
A1
SCALE 1 : 8
B2
B1B3
B4
DETAIL ASCALE 1 : 6
D-RING ASSEMBLY SHOULD BESECURED TO THE WALL USING1/4" HARDWARE (NOT SUPPLIED)
DD-A01-0100-04-04, INCLUDED ASSEMBLIESITEM # STS PART # DESCRIPTION QTY.
1 A01-0100-S-A TANK MANIFOLD WITH 0.500" NOZZLES 12 A01-0100-A TANK STRAP ASSEMBLY 13 800-111-FPS 100# RED TANK WITH LABEL 1
A01-0100-A, 100# Tank Strap AssemblyITEM # STS PART # DESCRIPTION QTY.
B1 800-155 TANK STRAP 1B2 800-157 D-RING ASSEMBLY 2B3 800-154 LIGHT DUTY PLASTIC BUCKLE 1B4 800-156 FINISHING TIP 2
A01-0100-S-A, TANK MANIFOLD WITH 0.500" NOZZLE CONNECTIONSITEM # STS PART # DESCRIPTION QTY.
A1 800-245-A TANK MANIFOLD 1A2 124-308 0.250" NPT M x F BALL VALVE, BRASS, MINIATURE 2A3 124-335-A 0.250" SAFETY RELIEF, 115 PSI, UCI 1A4 124-125 0.250" NPT x 02.000" 0-160 PSIG, BM 1A5 524-218 0.500" NPT F x 0.250" NPT M REDUCER, BRASS 2
(800-111) NITROGEN STORAGE TANK DESIGN DATAVOLUME 28 GALLONSWEIGHT 75 LBS
DRAWING ECR REV. DESCRIPTION DATE CHANGED BY APPROVED BY
REVISIONS
- - 1 UPDATED TITLE BLOCK AND TEXT FORMAT 7/22/2015 PJS JVNSCALE:
DATE:
APPROVED:
REVISION:
DD-A01-0100-04-04 1
PJS
1:12
DRAWN:
1 OF 1BNUMBER:
SIZE: SHEET:
DATE:
12/03/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
28 GALLON (100#) TANK ASSEMBLY DESIGN DATA
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
12/03/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
A1
14
12
A2
1114
BlastOffRelay
1112
B
A7
AM
PFU
SE B
LOC
K
TIMER
18NO
16NC A2
A1 15 Y1
~
~
-
+
A2 1816
15Y1A1
TIMER LOGIC RELAY LOGIC1411
12
A2
A1
JUMPERS
CUSTOMER FIELDCONNECTION
GRO
UND
BLO
CK
GRO
UND
BLO
CK
END
STO
P
END
STO
P
1 2 3 4 5 6 7 9 10
GENERAL NOTES:ALL TERMINAL BLOCKS OPEN SIDE WILL FACE RIGHT, OR DOWN IN FINAL INSTALLATION POSITION.(1)BOTH GROUND BLOCKS OPEN SIDE WILL FACE LEFT.(2)ITEMS IN RED ARE FOR THE ELECTRICAL WIRING IF BLASTOFF ASSEMBLY IS INSTALLED "STS PART# - A00-TYP2M ".(3)ITEMS IN BLUE ARE FOR THE ELECTRICAL WIRING IF BYPASS ASSEMBLY IS INSTALLED "STS PART# - TYP2M-N2-BP".(4)
8
110
VAC
+
110
VAC
-
GRO
UND
FUSE
BLO
CK
1211
BYPASSRELAY
14
A1
11
A2
12
14
24 VDCPOWER SUPPLY
+
L N
+ - -
TB-9B
TB-9A
TB-9C
TB-9D
TB-5B
TB-5C
TB-5D
TB-5A
TB-6A
TB-10A
TB-10C
TB-10D
TB-6B
TB-6D
TB-7D
TB-7A
TB-6C
TB-7C
TB-7B
15 " BLUE
15 " BLUE
TB-8A
TB-4A
TB-4C
TB-4D
TB-4B
3" BLACK
9-7/8" BROWN
6-3/4" BLUE
12-1/4" BLUE
11" BLUE
14-1/2" BLUE13-1
/2" B
ROW
N
6-1/2" BROWN
13" B
LAC
K12
-1/2
" BLA
CK
6-1/2" BROWN
10" BROWN
11" BROWN
15-1/4" BROWN
15-1/2" BLUE
2-3/4" BLACK7-3/4" BROWN
10-1/2" BROWN
10-1/4" BROWN
3-5/8" Black
3-5/8" WHITE
6" BLUE
12-7/8" WHITE
WHEN BLASTOFF IS ALARMING11-14 WILL BE CLOSED11-12 WILL BE OPEN
PRESSURE SWITCH
COM
NC NO
SWITCH
TOGGLE
5B
3B
1A
WHEN BYPASS IS ALARMING11-14 WILL BE CLOSED11-12 WILL BE OPEN24VDC
0V
110 VAC -110 VAC +
TB-8B
TB-2D
TB-2C
TB-2B
TB-2A
TB-1B
TB-1C
SOLENOID
HOUR METER
BUZZER
RED BYPASS LIGHT
STANDBY YELLOW LIGHT(GREEN FOR 07-HD)
RED BLASTOFF LIGHT
TB-1A
MAGNETIC SWITCHQC3-PINEMPTY
RED (N.O)
WHITE
BLACK (N.C)
WIRING TABLEAWG COLOR SERVICE FIELD/INTERNAL
14 CUST. DETERMINED 120 VAC FIELD14-16 BLACK +120 VAC INTERNAL14-16 WHITE -120 VAC INTERNAL16-18 BROWN 24 + VDC INTERNAL16-18 BLUE 0V INTERNAL16-18 YELLOW SIGNAL INTERNAL
TORQUE SPECIFICATIONSITEM MIN - MAX
TERMINAL BLOCK 0.4 Nm - 0.6 NmFUSE BLOCK 0.8 Nm - 1.6 NmGROUND BLOCK 0.4 Nm - 0.6 NmPOWER SUPPLY .67 Nm MAX
DRAWING ECR# REV. DESCRIPTION DATE CHANGED BY APPROVED BY
REVISIONS
- - 6 ADDED MAGNETIC SWITCH REMOVED COLD CLIMATE DRYER OPTION 8/21/2015 PJS JVN
- - 5 UPDATED TITLE BLOCK AND TEXT FORMAT 7/22/2015 PJS JVN
- - 1-4 OLDER REVS CONSOLIDATED AND FILED 7/22/2015 PJS JVNSCALE:
DATE:
APPROVED:
REVISION:
ES-TYP2M 6
PJS
2.5:3
DRAWN:
1 OF 1BNUMBER:
SIZE: SHEET:
DATE:
08/29/14PROJECT NAME:
SOUTH-TEK SYSTEMSWEIGHT:
MATERIAL:
FINISH:
TYPE 2M, ELECTRICAL PANEL WIRING
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SOUTH-TEK
SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH-TEK SYSTEMS IS PROHIBITED.
WHOLE NUMBER DIM's: 1ONE DEC.: .2, TWO DEC.: .02
THREE DEC.: .005 , ANG.: .05
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
JVN
08/29/14
D
C
B
A
18 7 6 5 4 3 2
D
C
B
A
8 7 6 5 4 3 2 1
DD-A01-0100-04-04, 100# TANK ASSEMBLY DESIGN DATA, (R1)Sheet1Drawing View1Drawing View2Drawing View5Detail View A (1 : 6)
DD-AC-JV, JV AIR COMPRESSOR DESIGN DATA AND DIMENSIONS, (R3)ASheet1Drawing View1Drawing View2Section View A-A
DD-RD-SC-10, SM-10 AIR DRYER, (R2)BSheet1Drawing View1Drawing View4Drawing View5Drawing View6
DD-TYP2M-FPS, N2-BLAST TYPE 2M DESIGN DATA, (R2)ASheet1Drawing View1Drawing View2Drawing View3Drawing View4Detail View Y (1 : 4)Detail View Z (1 : 5)Drawing View7
ES-TYP2M, TYPE 2M ELECTRICAL PANEL WIRING, (R6)ASheet1Drawing View1
GA-TYP2M-JV, GENERAL ARRANGEMENT, (R2)BGA-TYP2M-JV-01GA-TYP2M-JV-02Drawing View1
GA-TYP2M-JV-03Drawing View4Detail View Z (1 : 7)Drawing View6