1
SAUNA/INFRARED INTEGRATED
CONTROLLER NTS-200
Nature
ON
OFF
ON
OFF
NTS-200
SET
TIME
S A U N A /IN F R A R E D C O N T R O L
1 2 3
5
4
67
8
9
10
Figure 1 Infrared Sauna control panel NTS-200
Switch between “Infrared” and “Sauna” modes:When the panel is off, press
both “ON OFF” and “SET TIME” button,then and will display on the
screen by turns. Release both button when the mode you wish to choose appears, this
will confirm the mode. Wait for several seconds after the“ ” or“ ”display
disappears, then press “ON OFF” to turn on the panel and the panel is working in the
mode you have chosen. The default mode is Sauna Mode.
1. Sauna Mode Controller(Figure 1)
1. Hour indicator 2. Temperature display(display setting hour when not
heat-up) 3. Minute indicator
4. Heat preserving indicator(yellow) 5. Temperature and Time adjust button
2
6. Time setting mode button
7. ON/OFF 8. Fan 9. Lamp 10. Heating indicator (red)
Press “ON/OFF” button to turn on the control panel,system starts to work 3
seconds after the “ ”disappears.
Press both “▲” and “▼” button for more than 3 seconds to switch between
temperature units, “℃” and “℉” appears on the screen by turns. Release both button
when the temperature unit you wish to choose appears, this will confirm your choice.
3seconds later, the temperature unit display disappears and screen resume to display
current temperature in the unit you have chosen.
Press “▲” or “▼” button to adjust temperature,the screen blinks and display
the previous setting temperature in the range of 5-100℃(95-212℉). Press “▲”
to increase 1℃(2℉) or press “▼” to decrease 1℃(2℉),until you satisfied. System
will confirm your setting after 5 second no operation, and the screen resumes
displaying current temperature.
Press “SET TIME” button to adjust the waiting time. The maximum waiting
time is 12 hours. Led screen blinks and display hours in the form of “H10” which
means wait for 10 hours before heat up. Or display minutes in the form of “45” which
means wait for 45 minutes before heat up. Press “▲” to adjust hour value in the
range of 0~11hours and circle as 0→1→2……11→0→1. Press “▼” to adjust the
minute value in the range of 0~60 and with interval of 5 minutes. If you wish to set
12 hours waiting time, you need to set the hour value as “H11” and minute value as
“60”; if you wish to set 8 hours and 45 minutes waiting time, you need to set the hour
value as “H8” and minute value as “45”. Press “SET TIME” again to confirm you
3
setting and then enters the heating-time setting.
After setting waiting time or press “SET TIME” button twice, you could adjust
the heating time. Press “▲” to adjust hour value in the range of 0~5 or non-stop
mode (display “CH”). Press “▼” to adjust minute value in the range of 0~60 with
interval of 5 minutes. In non-stop mode “CH”, minute adjusting is unavailable. Press
“SET TIME” to confirm, then system enters waiting mode(if available), or
heating-up mode.
After entering the waiting mode, Led screen displays the hour (such as H10) and
minute (such as 45) information by turns. If the wait time is less than 1 hour, only
minute information is displayed. Once the waiting time is up, system enters
heating-up mode automatically. Led screen displays the current temperature, and left
side led lights indicate the remain working hour information in the following manner:
no light for less than 1 hour; bottom light turns on for 1~2 hours; bottom 2 lights turn
on for 2~3 hours and so on till all lights turn on for 5~6 hours. While the right side
led lights indicate the remain working minute information in the following manner:
bottom light blinks for less than 10 minutes; bottom light turns on for 11~20 minutes;
bottom 2 lights turn on for 21~30 minutes and so on till all lights turn on for 51~60
minutes. For example: 1:35 should be one button light turn on from the left and 3
lights turn on from the right.
Non-stop mode setting and display: Press the “▲” until “CH” appears. After
confirmation, the top lights of both sides blinks and system starts.
Press “ON/OFF” in waiting mode, system stops waiting and enters heat-up
mode immediately; Press “ON/OFF” in heat-up mode or heating-up time is up,
4
system enters ventilation mode. In ventilation mode, system switches on the fan and
keeps the room temperature above 40℃(104℉) for 45 minutes, then system switches
off.
Press during ventilation mode switches off the system immediately. Press
ON/OFF during ventilation mode stops ventilation and turns system back on.
The default setting temperature is 75℃, waiting time is 8 hours and
heating-uptime is 4 hours.
Temperature display range is 6-105℃(43-221℉).
Temperature adjusting range is 35-100℃(95-212℉).
Light switch:Press this button to turn on/off the light.
Fan switch:Press this button to turn on/off fan for ventilation.
Hint Message:
1) Temperature below 6℃(43℉):LED screen displays“ -L ”。
2) Temperature above 105℃(221℉):LED screen displays“ -H ”, system
can not heat up.
3) Communication error:Communication error between panel and mainboard,
LED screen displays“ EE”.
4) Heating-up indicator“ ”: The red indicator is on when system heats up。
5) Heat preserving“ ” indicator: Once reaching user-set temperature, system
stop heating up, and enter heat preserving mode. The yellow indicator turns on.
6) High-temp Protection:Once temperature reaches 110℃(230℉), Led screen
display “ HH”, system stop heating up. After temperature falls below 100℃
(212℉),press any key to restart system.
5
7) Temperature sensor error:If the sensor is not proper connected or not
function well, Led screen display “SE”.
2. Infrared Mode Controller (Figure 1)
1. Setting temperature indicator 2. Led display screen 3. Time indicator
4. Heat preserving indicator(yellow) 5. Time and Temperature adjusting
button 6. Time setting button
7. ON/OFF 8. Fan 9. Lamp 10. Heating-up indicator(red)
Press “ON/OFF” button to turn on the control panel,system starts to work 3
seconds after the “ ”disappears. Press “ON/OFF” again to turn off the system.
Press both “▲” and “▼” button for more than 3 seconds to switch between
temperature units, “℃” and “℉” appears on the screen by turns. Release both button
when the temperature unit you wish to choose appears, this will confirm your choice.
3seconds later, the temperature unit display disappears and screen resume to display
current temperature in the unit you have chosen.
Press “▲” or “▼” button to adjust temperature,the screen blinks and display
the previous setting temperature. Press “▲” to increase 1℃(2℉) or press “▼” to
decrease 1℃(2℉),and the adjustable range is 20℃~60℃(68℉~140℉). System
will confirm your setting after 5 second no operation, and the screen resumes
displaying current temperature. The setting temperature is indicated by the led
lights on the left of the panel in the following manner: the bottom light turns on for
temperature below 20℃(68℉); bottom two lights turn on for temperature between
21℃~30℃;and so on till all five lights turn on for temperature between 51℃~
6
60℃(124℉~140℉). The default temperature is 43℃(109℉), and temperature
display range is 6-65℃(43℉~149℉).
Press “SET TIME” button to adjust the heating time, the led screen blinks and
display the remaining working time. Press “▲” or “▼” to increase or decrease the
working time. The setting range is 1~60 minutes, value larger than “60” will display
non-stop mode “CH” on screen. Press “SET TIME” again to confirm your setting.
Then the system start to count down and the right side led lights indicate the
remaining working time in the following manner: the bottom light turns on for less
than 20 minutes; bottom two lights turn on for 21~30 minutes; and so on till all lights
turn on for 50~60 minutes. If in the non-stop “CH” mode, all lights turn on and the
top one blinks. The default working time is 45 minutes.
Hint message:
1) Temperature below 6℃(43℉):LED screen displays“ -L ”。
2) Temperature above 65℃(149℉):LED screen displays“ -H ”, system can
not heat up.
3) Communication error:Communication error between panel and mainboard,
LED screen displays“ EE”.
4) Heating-up indicator“ ”: The red indicator is on when system heats up。
5) Heat preserving“ ” indicator: Once reaching user-set temperature, system
stop heating up, and enter heat preserving mode. The yellow indicator turns on.
6) High-temp Protection:Once temperature reaches 70℃(158℉), Led screen
display “ HH”, system stop heating up. After temperature falls below 60℃
(140℉),press any key to restart system.
7
7) Temperature sensor error:If the sensor is not proper connected or not
function well, Led screen display “SE”.
Light switch:Press this button to turn on/off the light.
Fan switch:Press this button to turn on/off fan for ventilation.
3. Connections for different configurations of the Sauna/Infrared system
(Please refer to figure 2)
NOTICE:
Warning:The sauna heater and infrared radiator can no be used for other
heating purpose。
Notice:The product is not suitable for weak and disabled people, unless they
have been carefully supervised and take care of.
Notice:Children should be taken good care of for they safety.
Notice:Check the whole sauna/infrared room before turn on the controller.
8
N TS-200
Nature
ON
OFF
ON
O FF
NTS -200
SET
T IME
S A U N A /IN F R A R E D C O N TR O L
Suna Heater S tove
H eating E lem ents
54 6321
B REA KER
Tem p-sensor B ox
60W
C ontrolling R elay
240V A C
PO W ER IN PU T
L1 L2
M ainboard
Protecting R elay
Lam p
Fan
T em perature sensor
H igh-tem p Sw itch
C ontroller
C ontroller2
3-9kW ,240V A C 60H z
Sauna W iring D iagram
C IR CU IT
C ontrol B ox
321
L3 L4
T B -2510
T erm inal
N
60H z
G N D
120V
120V
N
L
L N
JU
MP
3 1 2 3 1 2C
ON
TR
OL
H -TEM P
TE
MP
SN
SN
R9
06
-Z
.PC
BJ1
3F
ANJ
5
LIG
HT
JM P4
JM P3
JM P2
JM P1
TE
ST
J1
0J9
J8
J7
J6
J4
J1
J3
J2
U6
K7
K6
K2
K1
F1
U5
GN
D
Figure 2
Calor de Hogar
Av Tecnológico 735, PB
San Salvador Tizatlalli
Metepec, 52172, Edo de México
Teléfono (722) 216 3330
(55) 1163 6038
www.calordehogar.com
servicio@calordehogar. omc [email protected]