Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
2239
Electrical Installation Software 2239
Megger Electrical InstallationTest Equipment
2239
ISO-TECH ElectricalInstallation Test Equipment
2242
Martindale ElectricalInstallation Test Equipment
2243
16th Edition Test Equipment 2244
InstalTest Installation Testers 2245
SANWA Insulation Testers 2245
Chauvin Arnoux ElectricalInstallation Test Equipment
2246
Fluke Electrical InstallationTest Equipment
2246
Earth Testing 2246
Clampmeters 2249
Power Measurement 2258
Energy Monitoring 2262
Portable Appliance Testing 2262
92 Lab Equipment,Environmental Monitoring &Calibration 2182
91 Bench Power Supplies 2172 94 Inspection & MechanicalMeasurement 2283
Test & MeasurementNetwork, Cable & Electrical Testing - contents
95 Multimeters 2310
96 Oscilloscopes 2340
97 Logic Analysers & SignalGeneration 2353
98 Test Leads & Accessories 2361
Flash/Hi-Pot Insulation Testers 2266
Cable Fault Locators 2267
Cable and Metal Detectors 2268
Mains Socket Testers 2269
Phase Rotation Testers 2270
Voltage Level Indicators 2271
Mains Voltage Indicators 1778
Automotive Voltage Indicators 2273
Magnetic Field Indicators 2273
Cable Test Equipment 2273
Network Test Equipment 2278
Telecom Test Equipment 2279
2236
www.nguyenxuong.com
Introducing the world’s first truly flexible clamp meter: The Fluke 376 with iFlex™.
Ask us about the FULL LINE of innovative Fluke clamp meters.
.
www.nguyenxuong.com
t� 5IF�NPTU�VTFE�BOE�USVTUFE�UFTUFS�NPSF�UIBO���CJMMJPO�DPQQFS�MJOLT�DFSUJGJFE
t� 3FEVDF�DPQQFS�DFSUJGJDBUJPO�DPTUT�VQ�UP�����QFS�ZFBS
t� 1FSGPSNT�GJCFS�DFSUJGJDBUJPO��Y�GBTUFS��
¦�����'MVLF�$PSQPSBUJPO��"MM�SJHIUT�SFTFSWFE��
DTX CableAnalyzer™ Series
Tested.Trusted.
www.nguyenxuong.com
Megger Insulation & Continuity Testers
Megger Combination Testers
Megger Multifunction Installation Testers
Electrical Installation CertificationSoftware
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
MIT480 Series Telecom Insulation& continuity test
LRCD220 Loop & RCD Tester
Megger MFT1700 Series
Contractor PAT & ElectricalCertification SoftwarePowersuite Professional Contractor offers all the features of PowerSuite
Lite with the addition of a data based client, assets and results
management database for managing 17th Edition electrical and Portable
Appliance test results. All records and downloaded data is allocated to the
appropriate customer on which a number of reports can be run
The LRCD200 series tester combines an Earth loop impedance
tester with an RCD tester. The loop tester is a non-tripping test
suitable for systems protected with 30mA or larger RCDs. The RCD
testing supports 10mA to 1000mA RCDs with the full range of tests.
Ramp testing provides a trip current test for the testing of nuisance
tripping RCDs. Suitable for use on 110V or 3 phase
supplies.,Designed to meet the tough environment of site work, the
instruments are rubber armoured, have a built-in protective front
cover, and meet the requirements of BS7671, IEC1010 and
BSEN61557. All instruments are IP54 weatherproof. The combined
instrument offers all the test functions necessary for live electrical
Telecommunication insulation and continuity testers developed to meet the
special requirements of telephone line testing, as well as the requirements of
electrical contractors and industrial testing to CATIV 600V. All instruments meet
TNV3 as well as IEC1010, HD384 and BSEN61557. The insulation test inhibit
voltage has been raised to 75V to overcome interference between cables
experienced at lower voltages, compared to 50V for standard cable testing.
Work in real certificates and forms
Client and results database manages links between customers and their
test results
Download test results from Megger downloading PAT testers, Megger
downloading electrical installation testers and third party test equipment
or direct data entry to certificates
Real time results transfer via Bluetooth with Megger MFT1553 electrical
installation tester
Import company logo and add header page to customise certificates for
testing requirements, in a simple and cost effective instrument.
All models:Complies with EN 61010-1 CATIV 600V safety rating
200mA & 20mA Continuity testing
Insulation test voltage display
75V test inhibit
TRMS and DC Voltage measurement
Dual Digital Display and Analogue bar-graph
Alkaline or NiMH rechargeable battery operation
Multifunction tester for all 17th
Edition and Part P testing
applications
2-wire no-trip & high current loop
testing
Auto-start tests on continuity and
loop resistance – no need to push
the button
Dual display shows loop resistance
and fault current results
simultaneously
Dual test buttons for left or right-handed operation
Weatherproof to IP54
Input protection against accidental connection to live circuits
CAT IV 300V safety standard
a professional appearance
Print on plain paper or pre-printed forms
Extensive range of certificate formats and supports IEE, NICEIC, ECA, SELECT and ELECSA and BS
electrical test certificates
Full range of PAT testing certificates including repairs cerificates
Reports module generates a wide range of reports for electrical installation testing and PAT testing.
Project billing certificates and reports
Digital imaging module allows picture import for increased clarity in reports
Organiser module for scheduling workload, site work and retesting etc. with graphical diary
Extended forms offer alternative and extra certificate formats including filling stations and security
systems, ensuring there is a certificate to meet your requirements
Built-in protective front cover
Tough rubber armoured case
Weatherproof to IP54
High current loop testing
Phase to phase loop testing
Auto RCD testing
1000mA RCD test
Phase rotation
110V, 230V and 415V operation
Backlit display
IP54 weatherproof housing
Test lock allows the insulation test to be held on indefinitely
MIT480 specific features50V & 100V insulation testing
100Gohms insulation range
MIT481 additional features50V, 100V, 250V, 500V, 1000V insulation tests
200Gohms insulation range
Leakage current display
kΩ resistance measurement
Timer, PI and DAR insulation tests
Insulation limit alarms
0.1nF to 10uF Capacitance measurement
Cable length calculated from an adjustable cable capacitance reference (default 50nF/km).
Test result storage (>1000)
MIT485 additional featuresResult download
Bluetooth capability (requires Bluetooth enabled PC or USB plus Bluetooth adaptor)
Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the
Megger extended 3 Year warranty
Note: System Requirements: Pentium IV PC running XP or Vista operating system; 128MB RAM
(Min); 100MB hard disk space; CD-ROM drive; COM1 RS232 port (or USB port with USB to RS232
adaptor) for use with downloading PAT testers; Bluetooth for use with Megger MFT1553
Supplied with: User Guide CD, 3-wire test lead with croc clips, Mains plug test lead, printed quick-
start guide, hard carry-case, 8 AA batteries
Stock no. Price per OM S$ S$ S$
667-8359 unit 1+ 1090·00
Supplied with: Durable hard carry case, instructions, 3 wire test lead with crocodile clips, BS1363
mains socket test lead, 8 off AA alkaline batteries.
MFT1710 MFT1720 MFT1730
Voltage & frequency 600V, 400Hz 600V (RMS),400Hz
600V (RMS), 400Hz
Polarity � � �
Insulation resistance testvoltages
250, 500 V 250, 500, 1000 V 100, 250, 500, 1000 V
Adjustable insulation alarm limits � �
Continuity Test Current 200 mA 15mA / 200mA 15mA / 200mA
2 Wire No Trip & High CurrentLoop Test with PFC
� (20KA PFC) � (40KA PFC) � (40KA PFC)
Phase to Phase Loop Test(480V) � �
RCD Test Range 100 - 280V45 to 65Hz
50 - 500V45 – 65Hz
50 - 500V45 – 65Hz
RCD Auto Test & programmable tripping currentlevel
� �
RCD ramp Test � � �
RCDs Type Tests AC, A (G&S) AC, A (G&S) AC, A (G&S)
3 Phase RCD Test � �
3 Wire Earth resistance �
Phase Rotation � �
Memory (1000 measurements) �
Bluetooth Interface �
Remote Switched Probe Included Included
Power 8 x AA alkalinebatteries
8 x AA alkalinebatteries
8 x AA NiMH rechargeable batterieswith charger included
Supplied with: Hard carry case, rubber boot with stand, silicone test lead set, SP5 remote switch
probe, 5 off AA alkaline batteries & instructions (CD-ROM).
Stock no. Price per OM S$ S$ S$
712-5749 unit 1+ 1441·00
Description Stock no. Price per OM S$ S$ S$
MFT1720 705-4751Sa unit 1+ 1759·00
MFT1730 705-4754Sa unit 1+ 2108·00
Applications
MIT480 MIT481 MIT485
Application Telecommunications
Insulation Voltage range
50V, 100V X X X
250V, 500V, 1000V X X
Insulation range 10GΩ 200GΩ 200GΩ
Leakage current display X X
Insulation test voltage display X X X
Continuity
Variable current limit 20mA or 200mA X X X
K ohms range to 999 K ohms X X
Measurements
Default voltmeter TRMS to 600V X X X
Frequency Hz- 40 to 400 Hz X X
Live circuit inhibit 75V X X X
Capacitance (0.1nF to 10μF) X X
Distance by Capacitance X X
Features
TNV3 compliant X X X
Switched remote probe X X
Backlight display X X X
Timer function (t PI DAR) X X
Storage and downloading
Test result storage X X
2239
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
MIT230 Insulation & ContinuityTester
MIT220 Insulation & ContinuityTester
BM12 Multi-Voltage Insulation &Continuity Tester
MIT 300 Series Insulation &Continuity Testers
The MIT230 is one of the smallest insulation testers available on the market
today. With options of a two voltage tester to a three voltage instrument, the
MIT230 instruments offer a range of safety and operation features.
A range of insulation testers that meet the relevant requirements
of EN61557, BS7671, HD 384, IEC 364 and VDE 0413 for
applications in all aspects of electrical contracting, building
maintenance, testing, inspection and servicing.
A battery powered multi-voltage insulation and continuity tester
incorporating a voltage measuring range. The BM12 is an analogue
instrument designed to meet the requirements of the IEE
regulations for testing electrical installations, and additionally
meets specification VDE 0413. Suitable for use on motors,
generators, transformers, and switchgear, the BM12 handles
insulation test voltages of 100, 250, 500 and 1000 volts d.c.
The MIT200 is one of the smallest insulation testers available on the market
today. With options of a two voltage tester to a three voltage instrument, the
MIT200 instruments offer a range of safety and operation features.
20mm LCD display with true analogue response
Tough rubber armoured case with self contained display cover
that locks away underneath the instrument during use
Designed to hang comfortably around the neck for hands-free,
or for bench use
Automatic 200mA fast continuity test on connection to the
Insulation testing to 1000MΩ
Dual & triple test voltages models
Digital display with electronic analogue arc display helps to confirm
insulation condition & to monitor fluctuating readings not apparent on the
digital display
Continuity testing at 200mA down to 0.01ohms resolution
Automatic discharge of circuit under test
1mA test current at selected voltage range
Default voltmeter automatically switches in when the instrument is
connected to a circuit with an AC or DC voltage greater than 25V
Autoranging analogue arc scale shows only the scale in use
Insulation testing to 1000MΩ
Dual & triple test voltages models
Digital display with electronic analogue arc display helps to confirm
insulation condition & to monitor fluctuating readings not apparent on the
digital display
Continuity testing at 200mA down to 0.01ohms resolution
Automatic discharge of circuit under test
1mA test current at selected voltage range
Default voltmeter automatically switches in when the instrument is connected
to a circuit with an AC or DC voltage greater than 25V
Autoranging analogue arc scale shows only the scale in use
Tests to BS7671 413-04-04, 713-02, 713-03, 713-04, 713-06.
Live circuit warning above 25V, also inhibits insulation & continuity tests above 50V
Lead resistance compensation on continuity
Hands free continuity testing Auto power-down after 5 minutes
Complies with IEC 1010-1 safety standard installation Category III, 600V phase to earth
Conforms to EN61557-1
Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04
Live circuit warning above 25V, also inhibits insulation & continuity tests above 50V
Lead resistance compensation on continuity
circuit
Lead resistance nulling on continuity allows for use of fused test probes
Automatic discharge of circuit under test
Safety input terminal interlock - prevents unsafe connection of test leads
Intelligent Safety System - even if connected to a live circuit whilst on continuity setting the tester
will remain safe and undamaged
Live voltage warning alerts the operator when a circuit voltage over 25V exists when insulation
testing
Safety lockout prevents the test from operating when the circuit voltage is > 50V
Continuity check - prevents a continuity test or buzzer test on a live circuit
3 phase safe - will not be damaged if connected across phases
Locking test button
Meets the requirement of BS EN 61010-1 for safe connection to a 440V Installation Category III
supply (600V Phase to Earth)
IP54
MIT310A
Dimensions (H x W xD)
128 x 180 x 125 mm Insulation testvoltages
100, 250, 500, 1 kV d.c.
Weight 1kg Terminal Current(ons/c) (insulationresistance)
1.9mA
Ranges Accuracy
Insulation resistance 0 to 2000MΩ (1mA) Insulation resistanceand continuityranges
Typically ± 1.5 of f.s.d.Conforms to VDE 0413 (parts 1and 4)
Continuity 0 to 4Ω (200mA) Voltage range ± 2.5 of f.s.d. Voltage 0 to 600V a.c. Batteries 6 x 1.5V cells IEC LR6 (AA)
Moving coil display
Stock no. Price per OM S$ S$ S$
616-661S unit 1+ 1820·00
Supplied with: 6 x AA alkaline batteries, test leads crocodile clips, carry case & instructions.
MIT320 benefits from the following additional features:
Model MIT220 Zero offset adjust 0 to 9.99ΩTest Voltage 250, 500V Continuity buzzer Operates <5ΩTest current onLoad
>1mA at minimum pass levels specifiedin BS7671, HD384, IEC364 & VDE0413 part1
Voltagemeasurementrange
25V to 600V @ 50/60Hz & dc
Insulation range 0.01MΩ to 1000MΩ on all ranges Accuracy 25V to 450V ac/dc ±(1% rdg +1d) 450V to 600V ac/dc ±(2% rdg +1d)
Measuringaccuracy
±(3% rdg +2d) to 10MΩ, ±(5% rdg +2d) to 100MΩ
Operatingtemperaturerange
-10 °C → +60 °C
Continuity Range 0.01Ω to 100.0Ω Battery life 3500 x 5 sec tests (typ) Open circuitvoltage
5V± 1V Dimensions /Weight
195 x 98 x 40 mm / 530g
Accuracy (20°C) <10Ω ±(3% rdg +2d) >10Ω ±(5% rdg +2d)
Result recall to screen X X
Bluetooth download X
Download software X
Backlit display and range selection ideal for low light environment
Selectable insulation alarm limit for fast go - no go testing
Selectable continuity alarm limit for fast go - no go testing
Resistance measurement range to 1 MΩ
SP3 switched probe supplied for one handed operation
SP1000 illuminated switched probe with ultra-bright LED light available separately
Description Stock no. Price per OM S$ S$ S$
MIT480 611-1285S unit 1+ 890·00
MIT481 611-1279S unit 1+ 1230·00
MIT485 611-1291S unit 1+ 1370·00
SP5 Switched Probe 611-1308 unit 1+ 76·00
BM200 Series Replacement Guide
Old BM200 Model RS stock no. BM Test voltage MIT220 RS 535-3185 MIT230 RS 535-3191
BM121 198-0294 250 � -
BM221 254-9658 500 � -
BM222 254-9664 500,1000 - �
BM223 254-9670 250,500,1000 - �
BM224 254-9686 500 � -
BM227 330-8379 250,500 � -
Supplied with: instructions, 2 wire test lead set with crocodile clips, 8 x AA alkaline batteries, neck
strap & carry case.
Stock no. Price per OM S$ S$ S$
535-3185S unit 1+ 610·00
Model MIT300 MIT310 MIT310A MIT320
Insulation ranges
250V Yes Yes Yes Yes
500V Yes Yes Yes Yes
1000V - Yes Yes Yes
Measuring range 10kΩ to 999MΩ 10kΩ to 999MΩ 10kΩ to 999MΩ 10kΩ to 999MΩ
Short Circuit Current 1.5mA nominal 1.5mA nominal 1.5mA nominal 1.5mA nominal
Test Current on Load@ min pass values of insulation(BS7671, HD384 & IEC364)
1mA 1mA 1mA 1mA
Accuracy (@ 20°C) ±3%, ±2 digits ±3%, ±2 digits ±2.5% of scalelength
±3%, ±2 digits
Insulation Limit Alarm 10kΩ to 1GΩ 10kΩ to 1GΩ 10kΩ to 1GΩ 10kΩ to 1GΩ
Continuity
Measuring Range 0.01Ω to 99.9Ω 0.01Ω to 99.9Ω 0Ω to 50Ω 0.01Ω to 99.9Ω
Open Circuit Voltage 5V ±1V 5V ±1V 5V ±1V 5V ±1V
Short Circuit Current 205 mA ±5mA 205 mA ±5mA 205 mA ±5mA 205 mA ±5mA
Zero Offset Adjust 0 to 9Ω 0 to 9Ω 0 to 0.5Ω 0 to 9Ω
Buzzer Operates @ <5Ω <5Ω <5Ω 1 Ω to 20Ω adj.
Buzzer Response time <20ms <20ms <100ms <20ms
Resistance (MIT320)
Measuring Range - - - 10Ω to 1MΩ
Open Circuit Voltage - - - 5V
Short Circuit Current - - - 200μA
Accuracy @ 20°C - - - ±3%, ±2 digits up to 100kΩ
Voltage
Measuring Range 0 to 600 Vac (50/60 Hz) or dc
0 to 600 Vac (50/60 Hz) or dc
0 to 600 Vac (50/60Hz) or dc
0 to 600 Vac (50/60 Hz) or dc
Accuracy @ 20°C dc or ac (50/60Hz)±1% ±2 digits
dc or ac (50/60Hz)±1% ±2 digits
±2.5% of scale length for 50/60 Hz
dc or ac (50/60Hz)±1% ±2 digits
Selection Guide
MIT300 MIT310 MIT310A MIT320
Resistance �
Voltage warning �
Default voltmeter � � �
Back-lit display �
Back-lit selector �
Auto power down � � �
Switched test probe �
Description Stock no. Price per OM S$ S$ S$
MIT300 Digital 516-7681S unit 1+ 550·00
MIT310 Digital 516-7697S unit 1+ 710·00
MIT310A Analogue 516-7704S unit 1+ 650·00
MIT320 Digital 516-7710S unit 1+ 830·00
2240
www.nguyenxuong.com
Megger Loop Testers
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
LTW 300 Series
SP1 Switched Probe Accessory
Megger MFT1800 Series
MIT400 Series Digital Insulation &Continuity Testers
LTW315
For use with BM80/2, BMM80 and BMM503 Insulation and Continuity
Tester
All instruments meet IEC1010, HD384 and BSEN61557, and are sealed to
IP54 for weatherproof performance.
Easy to hold and comfortable to use, the large display provides the
unique combination of two digital readouts and an analogue arc.
All primary results are displayed in the larger digital display and
repeated on the analogue arc. Additionally, auxiliary test information
such as frequency, leakage current, Insulation or circuit voltage etc is
displayed in the smaller secondary digital display.
Rubber over-moulding combines the tough shock absorbing outer
protection with excellent grip, on a strong modified ABS housing,
providing an almost indestructible case.
Battery requirements are 5 AA batteries of either standard Alkaline
(supplied) or Nickel Metal Hydride (NiMH) rechargeable type.
All models feature:
Multifunction tester for electrical
installation testing in accordance
with VDE 0100
2-wire no-trip & high current loop
impedance testing
Auto-start tests on continuity and
loop resistance
Simultaneous display of loop
resistance and fault current results
Dual test buttons for left or right-
handed operation
Earth loop impedance testers to verify the loop impedance of a
live electrical circuit without the need to disconnect the
electrical supply. The LTW300 series instruments offer a safe
and easy 2 wire loop testing solution that does not trip 30mA
RCDs and can be used on a wide range of voltages.
Stock no. Price per OM S$ S$ S$
232-8827 unit 1+ 80·50
Backlit display
0.01Ω resolution
No-trip loop test on circuits with RCDs of ≥30 mA
3 phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the
origin, even where only a phase and neutral contacts are
available.
10 second non trip loop test time with Auto test extension up
to a further 10 seconds if noise is detected, to improve the
Insulation testing to 1000V with Insulation test voltage display
Continuity testing at 200mA down to 0.01ohms
Alternative 20mA test current
AC/DC Voltage measurement
True RMS Measurement to 600V
50V Live circuit test inhibit
Complies with EN61010-1 CATIV 600V
IP54 weatherproof housing
Hard carry case
Optional SP5 switched probe with remote test button for single-handed operation
Hands free continuity testing Auto power-down after 5 minutes
Complies with IEC 1010-1 safety standard installation Category III, 600V phase to earth
Conforms to EN61557-1
Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04
Switched probe for ease of use
Weatherproof to IP54
Input protection against accidental connection to live circuits
CAT IV 300V safety standard
Supplied with: Durable hard carry case, silicone test lead set, AA alkaline batteries & instructions.
Note: German version
accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected; no need to
press the test button means much safer testing
Supplied with: 6 x AA alkaline batteries, test leads crocodile clips, carry case & instructions.
MIT400 Series Comparison table
MIT400 MIT 410 MIT420 MIT430 MIT40X Insulation Test Voltage
10V to 100V adjustable �
50V, 100V � � �
250V, 500V, 1000V � � � �
Insulation Resistance
100Gohm range � � �
200Gohms range � �
Leakage current display � � � �
Voltage/Frequency
Frequency � � �
Features
Remote switched probe � � �
PI and DAR timed functions � � �
Capacitance measurement � �
Storage and downloading
Test result storage � �
Result recall to screen � �
Bluetooth download & software �
MFT1815 MFT1825 MFT1835
Voltage & frequency 600V, 400Hz 600V (RMS),400Hz
600V (RMS), 400Hz
Polarity � � �
Insulation resistance testvoltages
250, 500 V 250, 500, 1000 V 100, 250, 500, 1000 V
Adjustable insulation alarm limits � �
200mA Continuity Test � � �
Loop Impedance Testwith PFC
� (20kA PFC) � (40kA PFC) � (40kA PFC)
Phase to Phase Loop Test(480V) � �
RCD Test Range 100 - 280V45 to 65Hz
50 - 500V45 – 65Hz
50 - 500V45 – 65Hz
Auto RCD Test � �
RCD ramp Test � � �
RCDs Type Tests AC, A (G&S) AC, A (G&S) AC, A, B (G&S)
3 Phase RCD Test � �
3 Pole & Stakeless Earth resistance �
Phase Rotation � �
Memory (1000 measurements) �
Bluetooth Interface �
Power 8 x AA alkalinebatteries
8 x AA alkalinebatteries
8 x AA NiMH rechargeable batteries withcharger included
General Dimensions/ weight 220 x 92 x 50 mm, 775g Battery life 2200 insulation tests with duty cycle of
5 sec ON /55sec OFF @ 1000Vinto1Mohm
Insulation Resistance
Basic Full ScaleAccuracy
± 3% ± 2 digits Measurement 0,01 kΩ to 1000 kΩ (0 to 1 MΩ onanalogue scale)
Insulation measurement resolution Accuracy ± 3% ± 2 digits Digital 0.01MΩ Digital Voltage range
Analogue range 1GΩ full scale 0 to 600Vdc ± 2% ± 2 digits Short CircuitCurrent
2 mA +0% -50% 10mV to 600V TRMSsinusoidal (40 to400Hz)
±2% ±2digit
Test Current onload
1mA at min. pass value of insulationspecified in BS7671, HD384 and IEC364,2mA max.
Default Voltmeter Operates at >25 volts a.c. or d.c. on anyrange except OFF
EN61557 Operatingrange
0,10MΩ to 1,00GΩ Frequency 40-450Hz (40Hz - 99,9Hz ±0.5% ± 1digit)
Continuity Capacitance (MIT420 & MIT430)
Measurement 0,01 Ω to 99,9 Ω (0 to 100 Ω onanalogue scale)
Measurementrange
100 pF to 10 uF
Accuracy ± 3% ± 2 digits (0 to 100Ω ) Accuracy ± 5.0% ± 2 digits Test current: 200mA (–0mA, +20mA) (0.01 Ω to 9.99
Ω) 20mA(±1mA ) (10.0Ω to 99.9Ω) Distance by capacitance: (MIT420 & MIT430)
Lead resistancezeroing
Up to 9,00 Ω Arithmetic conversion from capacitance measurement.
Buzzer Variable limit 1Ω, 2Ω, 5Ω, 10Ω, 20Ω Capacitance range 40nF/m to 60nF/m (default 50nF/m)
Model MIT230 Zero offset adjust 0 to 9.99ΩTest Voltage 250, 500V, 1000V Continuity buzzer Operates <5ΩTest current onLoad
>1mA at minimum pass levels specifiedin BS7671, HD384, IEC364 & VDE0413 part1
Voltagemeasurementrange
25V to 600V @ 50/60Hz & dc
Insulation range 0.01MΩ to 1000MΩ on all ranges Accuracy 25V to 450V ac/dc ±(1% rdg +1d) 450V to 600V ac/dc ±(2% rdg +1d)
Measuringaccuracy
±(3% rdg +2d) to 10MΩ, ±(5% rdg +2d) to 100MΩ
Operatingtemperaturerange
-10 °C → +60 °C
Continuity Range 0.01Ω to 100.0Ω Battery life 3500 x 5 sec tests (typ) Open circuitvoltage
5V± 1V Dimensions /Weight
195 x 98 x 40 mm / 530g
Accuracy (20°C) <10Ω ±(3% rdg +2d) >10Ω ±(5% rdg +2d)
Description Stock no. Price per OM S$ S$ S$
MFT1815 (German) 704-0474a unit 1+ 1897·00
MFT1825 (German) 704-0478a unit 1+ 2334·00
MFT1835 (German) 704-0487a unit 1+ 2893·00
Description Stock no. Price per OM S$ S$ S$
MIT400 535-3113S unit 1+ 710·00
MIT410 535-3129S unit 1+ 820·00
+ RS Cal. 535-6421S unit 1+ 1260·00
MIT420 611-1257S unit 1+ 960·00
MIT430 611-1263S unit 1+ 1070·00
MIT40X 611-1314S unit 1+ 900·00
Description Stock no. Price per OM S$ S$ S$
MIT230 Tester 535-3191S unit 1+ 670·00
MIT230 + RS Cal. 535-6487S unit 1+ 1250·00
2241
www.nguyenxuong.com
ISO-TECH Insulation & Continuity Testers
Megger RCD Tester
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
IIT2302 Digital Insulation/Continuity Tester
IIT2301 Analogue Insulation/Continuity Tester
IIT1601 Digital InsulationTester
RCDT310 & RCDT320 RCD Testers
Microprocessor-controlled, triple-voltage insulation tester
with high performance circuitry for fast data processing and
rapid display of readings. 200mA short-circuit current in
accordance with BS7671 regulations continuity test.
250V, 500V, & 1000V insulation test voltages
200 mA continuity short circuit current, fuse protected to comply
with BS7671 Wiring Regulations
Backlit display
Live circuit audible & visible warning
Lock-down button
Ohms zero-adjust to null out test lead resistance
Complies with safety standard EN610101-1 CAT III 300V
Tests to BS7671 413-04-04, 713-02, 713-03, 713-06, 713-08
Large backlit 3¾ digit, 4000 count LCD with analogue
bargraph
Insulation resistance to 4000MΩ autoranging
250V, 500V & 1000V insulation test voltages
Continuity to 40Ω, 200mA test current
Low battery warning
Continuity beeper
Lock and hold facility
Auto power off
Meets the requirements of EN61557 and BS7671 / wiring
regulations
Safety to EN61010-1 600V CAT III
Digital continuity and insulation tester
250/500/1000V insulation test ranges (1mA)
20/200/2000 Ohm continuity ranges with 200mA test
current
Auto null
Bar graph indication of test voltage
Live circuit warning
Protects against accidental connection to live circuit
Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.
Supplied with: Test leads and batteries.
Two RCD testers that comply with
EN61557 for testing, measuring or
monitoring of protective measures.
Insulation Test Ranges Open CircuitVoltage Output
4 to 9Vdc
DC Test Voltage 250V, 500V, 1000V Short CircuitCurrent Output
200mA min
Measuring Range(Mid Full Scale )
0 to 100MΩ (1MΩ)0 to 200MΩ (2MΩ)0 to 400MΩ (4MΩ)
Accuracy ± 3% of scale length
Output Current 1mAdc General
Accuracy 5% Withstand Voltage 5000Vac for 1 minute between electricalcircuit and case
Continuity Test Ranges Dimensions (H x Wx D)
175 x 115 x 86mm
Measuring Ranges0 to 2Ω, 0 to 20Ω Weight 640g
General
Power 12 Vdc (8 x 1.5 V AA)
Safety EN61010-1 600 V CAT III
Memory (Test results) Data hold function
Dimensions 77 x 140 x 190 mm
Weight 900g
AC Voltage
Voltage Range 0 → 600 V
Voltage Resolution 1 V
Voltage Accuracy ±(1.5 % rdg + 3 digits)
Overload Protection 750 Vrms
Insulation
Insulation Resistance Impedance Range 0 - 4000 MΩ
Resolution 1kΩ
Accuracy ±(3% rdg + 3 digits)
Output Short Circuit current 1.7 mA Max.
Continuity
Range 400Ω
Accuracy ±(1% rdg + 5 digits)
Overload protection 220Vrms
Continuity Beeper
Resolution 0.1Ω
Operation resistance <40Ω
Overload protection 220Vrms
Tests 30mA, 100mA, 300mA and 500mA rated RCDs
1/2x I, I, 5x I tests standard, DC and selective RCDs
0° or 180° polarity tests on all RCDs
Selective breakers have a time delay in tripping. When
selected, trip test times are extended and a 30s delay is
allowed between the measurement of the fault voltage
and the application of the test current
Selectable touch voltage inhibit and touch voltage display
on the analogue bargraph
Automatic capacitive circuit discharge on release of test button
Lock-down test button for continuous operation
Complies with safety standard EN61010-1 CAT III 300V
Description Stock no. Price per OM S$ S$ S$
IIT1601 697-3724S unit 1+ 636·00
PFC Display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the
secondary winding.
IP54 Weatherproof case
Optional 10A fused 2 wired test leads and crocodile clip set
Complies with IEC61010-1 300V CATIV safety standard and meets EN61557
300Vac (25 to 45Hz) voltage measurement range
Clear 20mm high digit LCD display with analogue arc bargraph
Tough rubber armoured case with self-contained display cover that locks away underneath the
instrument during use
Safety input terminal interlock - prevents unsafe connection of test leads
Safety lock-out prevents the test from operating when the circuit voltage is >300V
Stock no. Price per OM S$ S$ S$
530-5681S unit 1+ 460·00
RCDT320 model additional features
Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the
Megger extended 3 Year warranty
Supplied with: Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard
carry case and instructions.
10mA/1A RCD extended test capability
Backlit display and range selection ideal for low light environments
Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance
tripping of RCDs
Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically
perform a 1/2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester
proceeds to the next test automatically. All results are displayed at the end of the test
25 to 450Hz Frequency measurement range
Optional 2-wire test leads supplied
Voltage measurement
(ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440VDamage will occur if applied voltage exceeds 600Vrms Loop testing
No-trip loop and high current loop test
Source voltage LTW315: 100V to 280V (50Hz)LTW325: 50V to 440V (50Hz)
Display range 0.01Ω to 2000ΩAccuracy ±5% ±0.03ΩNominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at
nominal 230 Vac supply) Operational range 0.30Ω to 1000ΩProspective Fault Current (PFC)
Prospective fault current Measured Source Voltage / Loop resistance Maximum range 40 kA; accuracy is derived from loop test and voltage measurement. Safety
EN61010 Designed to EN61010-1 ed2 2001-02 Designed for 300 volts to Earth Category IV, withPhase to Phase voltages to 440 Volts; Fuse protected to 600 volts rms ac
EN61557 Complies with the following parts of EN61557, Electrical safety in low voltage systemsup to 1000V ac and 1500V dc- Equipment for testing, measuring or monitoring ofprotective measures: Part1-General Requirements; Part3-Loop resistance
Power supply
Battery 8 x 1.5V cells IEC LR6 type (AA alkaline) Rechargeable 8 x 1.2V NiCd or NiMH cells Battery life 2000 consecutive tests Mechanical
Weight 1000g ±10% excluding test leads Dimensions 203 x 148 x 78 mm
3-phase safe - Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation
Category III supply (300V phase to Earth)
Weatherproof to IP54
Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g
Description Stock no. Price per OM S$ S$ S$
LTW315 198-435S unit 1+ 910·00
LTW325 198-457S unit 1+ 1070·00
Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the
Megger extended 3 Year warranty
Supplied with: Instructions, Mains plug test leads, 8 AA alkaline batteries, neck strap.
Description Stock no. Price per OM S$ S$ S$
RCDT310 T RCD Tester 712-5737Sa unit 1+ 801·00
RCDT320 RCD Tester 712-5746S unit 1+ 880·00
RCDT320 RCD Tester,Aus version
163-974 unit 1+ 1050·00
2242
www.nguyenxuong.com
Martindale Insulation and ContinuityTesters
ISO-TECH RCD Tester
ISO-TECH Loop Testers
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Triple Voltage Insulation andContinuity Tester MartindaleIN2102
Fused Test Lead Set for Loop &RCD Testers
IRT2310 RCD Tester with DCtest
IRT1900 Digital RCD Tester
IPT2300 PSC Loop ImpedanceTester with Anti-RCD TripFeature
18 RCD test current ranges
Tests RCDs and DC sensitive breakers 1⁄2 x, 1x, and 5x device ratings
Constant current control circuitry permits accurate readings
even when mains fluctuates by ±10% at 240V
0° and 180° phase selection
LED status lights for easy reading in dimly lit areas
LED indication of correct wiring status
Excessive overvoltage warning with lockout
Tripping time resolution 1ms
Complies with safety standard EN610101-1 CAT III 300V
A fully specified insulation tester with 250V, 500V & 1000V insulation tests that
provides accurate testing and is ideal for single handed operation. The output test
voltage is automatically displayed during testing and confirms that the desired test
voltage is being developed. The automatic zero adjust removes the resistance of
the leads and the test button can be set to be either latching, to give a permanent
output, or "press to test".
Custom microprocessor for highest accuracy and
reliability
3 LED’s for checking correct wiring status
0° and 180° phase angle switch permits quick tests and
consistent readings
Visual indication of reversed phase & neutral wiring at
socket
Digital read out of tripping time
20/200/2000Ω loop impedance test ranges
PSC measurement to 20kA
Anti trip technology allows 15mA low current loop testing
without bypassing all RCD types
25A high current test for fast tests in noisy environments
and where tripping RCDs is not a consideration.
Fully protected against phase to phase connection
Earth probe for testing exposed metalwork
Colour coded LEDs for instant check of correct wiring
status
Complies with BS 7671 wiring regulations
Complies with safety standard EN610101-1 CAT III 300V
This auxiliary test lead is designed for use with a wide range of earth loop
impedance testers and RCD testers. Both the red and black probes are
fused to enhance the safety of the user. A pair of shrouded safety croc-clips
are also available.
Supplied with: Test leads
Note: Colour may differ from that shown.
Description Stock no. Price per OM S$ S$ S$
Fused test leads 216-839 unit 1+ 74·50
Shrouded Crocodile Clips 218-100 unit 1+ 20·10
250V,500V & 1000V insulation test voltages
200mA continuity test current with buzzer below 30Ω
5,000 count backlit digital display with analogue bargraph
Displays test voltage
Auto HOLD of test readings
Automatic discharge of circuit under test
Live circuit audible and visible warning
“Press to test” or latching test button mode to give a permanent output on
Note: Colour may differ from that shown.
Tests to: BS7671: 413-04-04, 713-02, 713-03, 713-04, 713-06, 713-08-01
Supplied with: BS1363 mains socket test lead, distribution board fused test leads with earth lead
crocodile clip, instruction manual test lead pouch and 8 x AA alkaline batteries.
Supplied with: carrying strap, mains leads for BS1363 mains socket outlets, test lead pouch and
instruction booklet.
General Fault condition setting x1/2, x1 & x5 Safety EN61557; BS7671, EN61010-1 300V CAT III Fault trip time 2000ms, 40ms (x5) Display Type LCD Low set resolution 1ms (x1/2, x1) & 0.1ms (x5) Dimensions 70 x 130 x 180mm Trip time accuracy ± (1% rdg + Dgts) Weight 800g Operating voltage 230V ±10%, 50/60Hz Specification Withstand voltage 3000V AC for 1 minute Tripping current 10 / 20 / 30 / 100 / 300 / 500mA Operating temperature & humidity 0 to 40°C below 80% RH
insulation test
Automatic zero adjust removes the resistance of the test leads
Complies with BS EN 61557 (17th Edition) UK and international standards
Complies with EN61010 CAT III 600V
Supplied with: 6 AA alkaline batteries, instructions, carry case, test leads and crocodile clips.
Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.
Test current settings 10, 20, 30, 100, 300,500 mA
Test current Factors 1/2X, 1X, 5X, DC
Fault Trip Current Duration 2000ms (1/2X, 1X, DC)50ms (5X)
Rated system voltage 230V +10% , -15%; 50Hz
Trip time accuracy ±(0.6% + 4 digits)
Safety Rating EN61010-1 CAT III 300V
Stock no. Price per OM S$ S$ S$
697-3777S unit 1+ 490·00
Range Test Current Accuracy
Loop Normal 0 → 20Ω 25A for 10ms 3% rdg ±4 digits
Loop Normal 0 → 200Ω 2.3A for 40ms 3% rdg ±4 digits
Loop Normal 0 → 2000Ω 15mA for 360ms 3% rdg ±4 digits
Loop Anti-Trip 0 → 20Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
3% rdg ±6 digits
Loop Anti-Trip 0 → 200Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
3% rdg ±6 digits
PSC Normal 0 → 20kA 25A Determined by loop accuracy
PSC Normal 0 → 2000A 2.5A Determined by loop accuracy
PSC Normal 0 → 200A 2.3A Determined by loop accuracy
PSC Anti-Trip 0 → 20kA P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
PSC Anti-Trip 0 → 2000A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
PSC Anti-Trip 0 → 200A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
Voltage Measurement 100 → 300V 50Hz - 2% ±4 digits
Insulation Test Ranges Accuracy 0 to 20Ω ±(1.5% rdg +5 dgt)0 to 200Ω & 0 to 2000Ω ±(1.5%rdg +5 dgt)
DC Test Voltage 250V; 500V; 1000V General
Measuring Ranges 20MΩ 200MΩ 2000MΩ Withstand Voltage 5000Vac for 1 minute betweenelectrical circuit and case
Output Voltage on OpenCircuit
250Vdc ±10%500Vdc ±10%1000Vdc ±10%
Overload Protection
Output Current 1mAdc Safety Standard EN61010-1 CAT III 300V Output Short Circuit Current 1.3mA approx Dimensions (H x W x D) 175 x 115 x 86mm Accuracy 20MΩ / 200MΩ ± (1.5% rdg +5
dgt)2000MΩ ± (10% rdg +3 dgt)
Weight 640g
Continuity Test Ranges
Measuring Ranges Short Circuit Output Current 200mA min
Stock no. Price per OM S$ S$ S$
712-7036S unit 1+ 544·00
Stock no. Price per OM S$ S$ S$
712-7032S unit 1+ 740·00
IN2102 Accuracy ±3% ± 5 digit Display Digital Short circuit test current >200 mA Insulation Resistance Ranges 4/40/400/1000MΩ (250 V)
4/40/400/4000 MΩ (500 V)4/40/400/5000 MΩ (1000 V)
Resistance Range 0.1Ω to 1999 kΩ
Accuracy ±3% ±5 digit Accuracy ±3% ±5 digit Test voltage 250 V, 500 V, 1000 Vdc Test voltage 4 Vdc nom. Short circuit current <1.5 mA Voltage test range 0 → 600 V ac/dc Continuity Range 40Ω Accuracy ±3% ± 5digit
Stock no. Price per OM S$ S$ S$
530-5697S unit 1+ 420·00
Stock no. Price per OM S$ S$ S$
379-472S unit 1+ 700·00
2243
www.nguyenxuong.com
Combined Test Equipment
Kyoritsu Insulation Testers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
4120A Kyoritsu Loop/PSC Tester
6010A 5-in-1 Multi Function Tester
6050 Loop/RCD Combi Tester
3007A Microprocessor DigitalInsulation & Continuity Tester
3125 High Voltage Insulation Tester
Large custom digital display readout
Custom microprocessor controlled for highest
accuracy and reliability
3 LEDs for checking correct wiring status
Wide range measurements from 500V to 5000V and
up to 1000GΩ
Large digital display with Bar Graph indication and
back light
Continuity and Insulation Testing
Bargraph to display insulation resistance
6050 Combi tester provides the ultimate in
Microprocessor technology offering Loop and RCD
tests with a comprehensive memory and facility for
downloading test results
Displays the value of external AC voltage along with flashing
symbol
Trac-Lok mode to conserve battery life on insulation and
continuity tests
Live circuit warning beeper
Backlight function
LOOP impedance 2000Ω range measurement is carried out
with a low test current (15mA) which will not trip the most
sensitive (30mA) RCDs
In-built Automatic RCD(ELCB)lock device. There is no need to
by-pass most passive RCD’s at distribution boards when
conducting LOOP or PSC tests
Direct reading of Prospective Short Circuit Current (PSC) and
earth fault currents
Safe voltage measurement function
Automatic lock-out if test resistor overheats
Visual indication of reversed phase-and-neutral wiring at
socket
Polarization Index measurement (PI)
Timer measurement function
Indication of Output voltage and Discharge voltage
Auto-discharge function and Voltage output warning function
Auto power off and Battery Check
Supplied with a line probe, earth cord, guard cord, pickle type cord,
alkaline batteries LR14 x 8 pcs and hard carrying case
Live circuit warning LED: Immediate illumination of
a warning lamp if the circuit under test is live
Auto Discharge:Allows fast and safe discharge of
LOOP Impedance 200/2000Ω range measurement is carried out
using a test current of 15mA which will not trip RCD’s rated at
30mA or greater
High resolution for low Loop Impedance (resolution of 0.01Ω) on
20Ω range
Direct reading of Prospective Short Circuit Current (PSC) and
earth fault current
RCD tests at 0 and 180 degree phase angle switch permit quick
tests and consistent readings
RCD Ramp test in order to indicate the actual tripping current of
RCD
Constant current source circuitry ensures that a fluctuating mains
voltage does not affect the accuracy of readings
Visual indication of correct wiring status and automatic lock-out
if test resistor overheats
Contact Voltage Reading (UC) with two selectable contact
voltage limits (25 and 50V)Supplied with: Pouch with test leads, shoulder strap
electrical energy stored in capacitive circuits following
testing
Integral overload protection on internal continuity and
insulation test circuitry
Standards: IEC 61010-1 CAT.III 300V, IEC 61557
Standards: IEC61010-1, CAT III 300V Pollution Degree 2,IEC61010-2-031, IEC61557-1/2/4
Standards: IEC61010-1 CAT.III 600V Pollution degree 2
Loop and RCD Testing
Supplied with: Pouch with test leads, shoulder strap and batteries
Standards: IEC61010-1 CAT.III 300V, IEC61557-1,-3, IEC61010-2-031 Pollution Degree 2,IEC60529-IP54
Range Insulaton resistance Voltagemeasurement
500 V 1000V 2500V 5000V AC/DC V
Measuring range 0.0-99.9MΩ 0.0-99.9MΩ 0.0-99.9MΩ 0.0-99.9MΩ
100-999MΩ 100-999MΩ 100-999MΩ 100-999MΩ AC/DC
1.00-1.99GΩ 1.00-9.99GΩ 1.00-9.99GΩ [50/60Hz]
10.0-99.9GΩ 10.0-99.9GΩ
100-1000GΩ
Accuracy ±5 % rdg ±3dgt ±5 % rdg ±3dgt ±5 % rdg ±3dgt ±5 % rdg ±3dgt(±20% 1000GΩ
range)
±2 % rdg ±3dgt
Short Circuit Current 1.3mA approx. -
Rated test current 1 to 1.2mA at0.5MΩ load
1 to 1.2mA at1MΩ load
1 to 1.2mA at2.5MΩ load
1 to 1.2mA at5MΩ load
-
Open circuit voltage 500Vdc +30%-0%
1000Vdc +20%-0%
2500Vdc +20%-0%
5000Vdc +20%-0%
-
Max display 999 Counts (1000 counts only at 1000GΩ) 630 Counts
Current consumption Approx.1000mA (During measurement) 25mA approx.
Withstand voltage 5320V AC for 5 seconds
Power supply DC 12V: 1.5V R14 × 8
Dimensions 205(L) × 152(W) × 94(D) mm, weight approx. 1.8kg
Insulation Resistance Ranges Output Voltage 7 - 12V DC Test Voltage 250V/500V/1000V Measuring Current 200mA DC min Measuring Ranges 20MΩ/200MΩ/2000MΩ AC Voltage Range 0 - 600V AC Output Voltage on Open Circuit Rated Test Voltage +20%, -0% General Specifications
Nominal Current 1mA DC min Power Source R6P (AA) (1.5V) x 8 Output Short Circuit Current 1.5mA DC approx. Dimensions (mm) 185 (L) 167 (W) 89 (D) Continuity Test Ranges Weight 990g approx. Measuring Ranges 20MΩ/200MΩ/2000MΩ
Stock no. Price per OM S$ S$ S$
627-8760 unit 1+ 1000·00
Stock no. Price per OM S$ S$ S$
466-6014 unit 1+ 540·00
Wiring connection check LEDs: Immediate indication if
wiring of circuit under test is correct
Overheat Protection:Rapid detection of overheating of
internal circuitry, display of warning signal to user and
automatic halting of measurement
Supply Voltage Indication: Can display supply voltage
value in loop impedance mode
Low Current Loop Impedance Test: Short duration low
test current will prevent tripping of many passive RCDs
Phase Angle Selection: Selection of test current from +ve
or -ve half cycle of waveform can prevent tripping of
polarized type RCDs
Loop Impedance Ranges (Z reading) 20/200/2000Ω 1000ms: x1/2, x1, DC Max test current on Loop ranges 3A (20Ω) / 15mA (200
and 2000Ω) 200ms: x5, DC (500mA), & x1
(1000mA) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Ramp Test From 20% to 110% of
IΔn (AC type) RCD Test AC Type (Standard and Selective) Contact Voltage Reading (RCD) 100.0V x1/2: 10, 30, 100, 300, 500,
1000mA Working Voltage for Loop Tests 20Ω: 230V+10%-15%
x1: 10, 30, 100, 300, 500,1000mA
200/2000Ω:230V+10%-15% and400V+10%-15%
x5: 10, 30, 100mA Working Voltage for RCD Tests 230V+10%-15% Auto Ramp: 10, 30, 100, 300, 500mAVoltage Tests 100 ∼ 260V RCD Test A Type (Standard andSelective)
10, 30, 100, 300, 500mA (LOOP 200/2000Ω,PSC 200A:100 ∼ 440V)
RCD Test Currents multipliers x1/2, x1, x5 Memory 300 memory locations (max 1000mA type AC)Dimensions 186(L) x 167(W) x
89(D)mm (max 500mA type A) Weight 980g
RCD Test Time Duration
Standards: IEC61010-1 CAT.III 300V Pollution Degree
Stock no. Price per OM S$ S$ S$
255-049 unit 1+ 470·00
2, IEC61010-2-031, IEC61557
Continuity Testing Output Voltage on Open Circuit 570V DC±6% Measuring Ranges (0-19.99) and 10.0-
199.9Ω (2 auto ranges) Rated Current >1mA(as per IEC364)
Open Circuit Voltage > 4V(as per IEC364) Accuracy ±(3% + 3dgt) Short Circuit Current > 200mA DC(as per
IEC364) RCD Testing
Accuracy ±(3% + 3dgt) Rated Voltage 230V AC +10%-15%(50Hz)
Loop Impedance Testing Trip Current Settings RCD × 1/2: 5, 15, 50, 150,250mARCD × 1: 10, 30, 100, 300,500mA
Rated Voltage 230V AC +10%-15%(50Hz)
Trip Current Duration RCD × 1/2 × 1: 2000ms
Voltage Measuring Range 100-250V AC (50Hz) Fast Trip 150mA Impedance Range Nominal TestCurrent
20/2000Ω 25A(20Ωrange) 15mA(2000Ω range)
Accuracy Trip current ±3% of testcurrent at 230V. Trip time ±(3% + 3dgt)
Test Period 1/2 cycle (10ms) General
Accuracy 20Ω range : ±(3% +8dgt) 2000Ω range :±(3% + 8dgt)
Withstand Voltage 4000V AC for 1 minute
Insulation Testing Power Source R6P(AA)(1.5V) × 8 Measuring Ranges 0-19.99 and 10.0-
199.9MΩ (2 auto ranges)Dimensions 175(L) × 115(W) × 86(D)
mm Test Voltage 500V DC Weight 780g approx.
Manu. Part No. Stock no. Price per OM S$ S$ S$
6010A 627-8776 unit 1+ 460·00
2244
www.nguyenxuong.com
Sanwa Insulation Testers
Chauvin Arnoux Electrical Installation TestEquipment
Combination Testers
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
DM 1528S Analogue InsulationResistance Tester
DM 508S/DM 1008S AnalogueInsulation Resistance Tester
DG7 Mini Digital Insulation Tester
CA6521, CA6523 andCA6525 Insulation Testers
Instaltest Combo MI-3125 Seaward Electronic
Technical Specification - General
Display 4200-count LCD with LogBargraph
Operatingtemperature
0 to 40°C
Measurementnethod
Average value sensing Operating humidity 0 to 90% non-condensing
Sampling rate 2 readings per second Power source 6 x AA cell, Alkaline forMG1000
Range selection Auto only; Up at >4200, Downat <380
Size and Weight 170 x 142 x 57 mm, 600 g
A compact light weight easy to use insulation resistance tester. Inner
magnetic field taut-band type meter gives a reliable stable needle
indication. The Auto-discharge function is also featured.
Compact light weight easy to use insulation resistance testers. Inner
magnetic field taut-band type meter gives a reliable stable needle
indication. The Auto discharge function is also featured. Digital LCD with simulated analogue arc bargraph
200mA continuity test capability
Super small pocket size & compact insulation tester
Various test voltages available
Wide measurement range
Data hold functionality
Auto power save (30min.) to conserve battery power
Sampling rate : 2 times / sec. for numeral display, 20
times for bargraph
Technical Specification - Measuring Ranges
Insulation resistance MG500 MG1000
Measuring ranges 5: 400.0 kΩ to 4000 MΩ 4: 4.000 MΩ to 4000 MΩ
Test voltages 125-250-500V 250-500-1000V
Bargraph centre scale 10-100-1000 MΩ 10-100-1000 MΩ
Accuracy
1st effective meas range ±(3% rdg +4 digits) ±(3% rdg +4 digits)
2nd effective meas range ±(5% rdg +5 digits) ±(5% rdg +5 digits)
Resistance/Continuity (MG500 & MG1000)
Range Resolution Accuracy
4000 Ω (+ buzzer) 1 Ω ±(3% rdg +3 digits)
40.00 Ω 0.01 Ω ±(3% rdg +10 digits)
Voltage AC/DC (MG500 & MG1000)
600 Vac/dc 1 V ±(3% rdg +2 digits)
Input resistance: 9 MΩ Overload: 780 Vrms
Continuity buzzer
Lead resistance compensation (Not CA6521)
Auto power down to save batteries
Battery life indication
Programmable thresholds with buzzer alarm
Timer measurements over long periods (CA6525 only)
IP54 ingress protection
3 range tester for maximum versatility
MΩ measuring switch allows one-shot and continuous
measurements
dc voltages up to 60V can be measured
ac voltages up to 600V can be measured
Handy neck strap for hands free operation
IEC 1010-1 CATIII 600V
JIS C 1302-1994
Description Stock no. Price per OM S$ S$ S$
MG500 543-302 unit 1+ 450·00
MG1000 543-308 unit 1+ 495·00
The 3-in-1 multi-function tester, installation
tester and pass/fail tester
MΩ measuring switch allows one-shot and continuous
measurements
dc voltages up to 60V can be measured
ac voltages up to 600V can be measured
Handy neck strap for hands free operation
IEC 1010-1 CATIII 600V
JIS C 1302-1994
BestAccuracy
± (2% + 0 to 4digit)
Battery Silver OxideCell SR44 x 2
Resolution 0.001 MΩ Size 117(H) x 76(W)x 18(D) mm
Display 4000 Weight 125g
MG Series Testers
Supplied with: 6 x LR6 batteries, "Hands-free" shoulder bag and test leads.
Function Range 250V Insulation Test 0.05 to 500MΩ
1000V Insulation Test 1 to 2000MΩ ac Voltage 0 to 600V500V Insulation Test 0.5 to 1000MΩ dc Voltage 0 to 60V
Function Range ac Voltage 0 to 600V500V Insulation Test DM 508S 0.5 to 1000MΩ dc Voltage 0 to 60V500V Insulation Test DM 5 to 2000MΩ Battery life DM 508S 5.5 hours1008S Battery life DM 1008S 4 hours
Stock no. Price per OM S$ S$ S$
627-8726 unit 1+ 305·00
Replaces multimeter, insulation tester, RCD tester, loop
impedance tester and phase sequence tester
Installation verification tests to AS/NZS3017 covering earth
continuity, insulation resistance, polarity, correct connections,
fault loop impedance and RCD tests
Tests sockets in seconds with single push button and without
trailing leads
Preset and user defined Pass/Fail limits with on-screen tick/cross
plus red/green LED indicators
Model Number CA 6521 CA 6525
Insulation
Voltage (V) 250, 500 250, 500, 1000 Range (Ω) 50k to 2000k 50k to 2000k Accuracy ±(3% + 5digts) ±(3% + 5digts) Continuity
Range (Ω) 0 to 19.99 0 to 19.99 Resolution (Ω) 0.01 0.01 Accuracy ±(3% + 5digts) ±(3% + 5digts)
Manu. Part No. Stock no. Price per OM S$ S$ S$
DM508S 384-1309 unit 1+ 245·00
DM1008S 384-1315 unit 1+ 275·00
Supplied with: Test leads, test probes, alligator clips and resistor
box
Insulation Resistance Testers
Stock no. Price per OM S$ S$ S$
384-1292 unit 1+ 320·00
Loop Impedance Ranges 20/200/2000Ω (20/200Ω D-LOK) PSC Ranges 200A (2.3A 40ms) Loop Impedance Accuracy ±2% rdg ±4 dgt 2000A (25A 20ms) D-LOK AC Test Current 20Ω 25A 20kA (25A 20ms) D-LOK
200Ω 2.3A PSC Ranges Accuracy ±2 % rdg ±4dgt 2000Ω 15mA Voltage 110V-260V ±2% rdg ±4 dgt
AC Test Period 20Ω (20ms) Operating Voltage 230V +10% -15% (195 - 253V) 50Hz 200Ω (40ms) Dimensions 185(L) × 167(W) × 89(D) mm 2000Ω (280ms) Weight 960g
Warning of live (>30V) circuit detection via buzzer and red warning LED
Buzzer plus large "flash" symbol on LCD alert user when test voltage is
generated
Operation of highest test voltage is interlocked to prevent inadvertant
or accidental operation
Large log scaled bargraph allows measured value to be checked with
the same ease-of-use as an analogue tester.
Automatic data hold for last measured value
Backlight allows use in poorly lit conditions
Durable and tough body, with easy-to-hold "portrait"shape
Case is fitted with carrying strap and non-slip side grips for safe and
secure handling
Display 128 x 64 dot matrix LCD with backlight
Power source 6 x 1.5V batteries
Enclosure rating IP40
Dimensions 230 x 140 x 80mm
Overvoltage Category 600V CAT III, 300V CAT IV
Weight 1000g
Loop Impedance Test Type 3 wire Automatic RCD Test Yes Download Yes Non Tripping Yes
Stock no. Price per OM S$ S$ S$
255-039 unit 1+ 520·00
Standards: IEC61010-1 Cat III 600V
Stock no. Price per OM S$ S$ S$
712-6023a unit 1199·00
Supplied with: Test lead set & Instructions
2245
www.nguyenxuong.com
Earth Testing
Fluke Insulation and Continuity Testers
Fluke Installation Testers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Fluke 1625 GEO Earth Ground Tester Kit
Fluke 1507 / 1503 Insulation Testers
Fluke 1650 Series
A comprehensive earth tester capable of conventional 3 and 4
pole measurement of the resistance of earth installations, and
ground resistivity. It offers many advanced features, including
’selective’ earth testing and ’stake-less’ earth testing.The
stake-less method is able to measure the resistance of individual
ground connections in multi grounded systems without the use
of ground stakes; 2 clamps are clamped around the earth rod so
leaving the bonded earth ground system intact during testing.
Using this method, earth resistance tests can be conducted
where there is on access to soil.
3- and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-pole resistance measurement AC
2- and 4-pole resistance measurement DC
Insulation test range: (1507): 0.01MΩ to 10GΩ, (1503): 0.1MΩ to 2000MΩ
Insulation test voltages: (1507) 50V, 100V, 250V, 500V, 1000V; (1503) 500V,
1000V
Automatic calculation of Polarization Index and Dielectric Absorption Ratio
(1507 only)
Compare (pass/fail) function (1507 only)
Remote test probe
Live circuit detection prevents insulation test if >30V is present
Auto-discharge of capacitive voltage
Voltage range 0.1 to 600Vac/dc
Continuity 200mA
Resistance 0.01 to 20kΩ
Multifunction installation testers to verify the safety of
electrical installations in industrial, commercial and
domestic applications
Meet the requirements of IEC 60364, HD 384 and BS 7671
17th Edition wiring regulations
Large illuminated display with exceptionally wide viewing
angle
Rugged: withstand a one meter drop for demanding field
use
Selective testing with no disconnection of ground conductor (using one clamp)
Stake-less testing with no disconnection of ground conductor and no ground stakes for quick
ground loop testing using 2 clamps
Resistance measurement without current or voltage spikes for rapid testing of pole mounted
transformers.
Earth impedance measurement at 55 Hz
Automatic frequency control (94, 105, 111, 128 Hz) selects a measuring frequency to minimise the
effect of existing interference
Selectable test voltage20/48V enables safe testing where livestock may be present
IP56 splash-proof case
Programmable GO / NO-GO limits, settings
Continuity with buzzer
All inputs are protected to EN 61010-1, CAT III 500V
Battery indicator, and battery test function
Weight 1.2kg
Supplied with: Remote probe, test leads, test probes, alligator clips, holster, user
documentation.
Supplied with: 2 test leads, 4 earth ground stakes, 3 cable reels with wire (2 x 25m, 1 x 50m), clamp
set for selective / stake-less (one inducing, one sensing), batteries, manual, carrying case.
AC/DC Voltage Accuracy Short circuit current 1mA nominal Range accuracy 600.0V General Specifications
Resolution accuracy 0.1V Max. voltage applied to any terminal 600Vac rms ordc
50Hz to 400Hz +/- (% of Rdg + Digits)accuracy
+/-(2% + 3) Operating temperature -20 °C → +55°C
Overload protection 600V rms or dc Dimensions H203 x W50 xD100mm
Earth Bond Resistance Measurement Weight 550g Range accuracy +/-(1.5% + 3) Overload protection 2V rms or dc Height (mm) 203 Insulation Specifications Width (mm) 50 Test voltages 1507; 50V, 100V,
250V, 500V,1000V1503: 500V,1000V
Depth (mm) 100
Test voltage accuracy +20%, -0% Weight 0.5 kg
Support Accessories:
Display 4 digit 3000 count LCD Accuracy ±7% of range +2 digits 3 & 4- pole measuringrange
0.001Ω to 300kΩ Operating errors ±10% of range +5 digits
Accuracy ±2% of range +2 digits Test current 250mA a.c. short circuit Operating errors ±5% of range +5 digits Test voltage 20V / 48V a.c. Selective rmeasuringranges
0.001Ω to 30kΩ Battery life Typical 3000 measurements(RE+RH ≤ 1kΩ)Typical 6000 measurements(RE+RH ≤ 10kΩ)
Accuracy ±7% of range +2 digits Dimensions (W x H x D) 250 x 133 x 187mm Operating errors ±10% of range +5 digits Weight 1.1 kg including batteries
5.5 kg including accessories andbatteries in carrying case
Stake-less measuringrange
0.001Ω to 30kΩ Working temp. range -10 °C → +50 °C
TP165X remote probe Slim line remote probe with built-in test button to facilitate one-handed
measurements on Fluke 1650 & 1650B series installation testers see 468-0616
TL165X fused test lead set see 468-1063
Earth Spike Test kit: For earth resistance testing on the Fluke 1653 & 1653B using the 3 wire
connection method and auxiliary earth spikes.
Contains Auxiliary earth probes, test connection leads and crocodile clips, purpose-made carry
case . See 468-0600
FVF-SC2 FlukeView� documenting software: for documenting, storage and analysis of
measurements, from the Fluke 1653B and 1654B. Allows editing of an existing form or creation of a
new form to customize the report to individual needs
Contains software on CD-ROM and USB/ IR interface cable See 385-0599
Lead Compensation No YES Resistance
Range (Ω) No 0 to 399.9k Resolution (Ω) No 0.1/1/10/100 Accuracy No ±(3% +2digts) Voltage
Range (V) 0 - 600 ac/dc 0 - 600 ac/dc Resolution 0.1/1V 0.1/1V Accuracy ±(3% + 1digt) ±(3% + 1digt) Alarm No YES Timer No 0 to 15 mins Size (WxHxD) & Weight 108 x 211 x 60mm, 835g 108 x 211 x 60mm, 835g Safety IEC 61010-1 CAT III 600V IEC 61010-1 CAT III 600V
Description Stock no. Price per OM S$ S$ S$
1503 518-5998S unit 1+ 737·00
1507 518-6008S unit 1+ 858·00
Description Stock no. Price per OM S$ S$ S$
CA6521 346-7355S unit 1+ 680·00
CA6525 346-7377S unit 1+ 870·00
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
645-1820 unit 1+ 6133·00
Note: 6AA Alkaline are originally supplied, 1.2V NiMh are also suitable; all stored data will be lost if
batteries are not replaced within approximately 1 minute for model 1653B and 1654B
RS is currently unable to supply replacement fuses for these products.
Supplied with: (All models): detachable leads (TP165X & TL165X), 6 AA cell batteries, a durable
hard carrying case, padded carrying strap, mains test cord, quick reference guide.
1651B 1652C 1653B 1654B
Voltage, frequency � � � �
Polarity � � � �
Insulation resistance testvoltages
250, 500,1000V
250, 500,1000V
50, 100, 250, 500,1000V
50, 100, 250, 500,1000V
Continuity & Resistance � � � �
Fast, high current loop test � � �
High current loop test with 1 mΩ resolution �
Non trip loop impedance test � � � �
RCD tripping time � � � �
RCD tripping current level ramp test � � �
RCD auto test & ramp test � � �
Standard AC RCD tests (G & S-Type)
� � � �
Pulsating DC sensitive RCD tests (G & S-type) � � �
Earth resistance (RE) � �
Phase sequence indicator � �
Memory (500 measurements) � �
IR interface for data downloading � �
Remote Probe � � �
Description Stock no. Price per OM S$ S$ S$
Fluke 1651B 712-5954S unit 1+ 1536·00
Fluke 1652 Aus/NZ 482-1974 unit 1+ 2833·00
Fluke 1653 Aus/NZ 482-1952 unit 1+ 2550·00
Fluke 1653B 712-5951S unit 1+ 2574·00
Fluke 1654B 712-5960S unit 1+ 2789·00
Accessories
Description Stock no. Price
per
OM S$ S$ S$
FVF-SC2 Flukeviewsoftware
385-0599 unit 1+ 390·00
ES165X Earth Spike Kit 468-0600 1 kit 1+ 282·00
TP165X Remote Probe 468-0616 unit 1+ 127·00
TL165X Fused Lead Set 468-1063 unit 1+ 185·00
2246
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
DLR010HD Heavy Duty 10A LowResistance Ohmmeter
Digital Low Resistance Ohmmeter
DET4TCR/2 4 Pole Earth Tester
Earth Testing Field Kit
DET4TC 4 Pole Earth Tester
This kit provides all the necessary equipment to enable
earth testing to be carried out in conjunction with a 3 or 4
pole earth tester
4 pole earth tester with rechargeable batteries for measuring
soil resistivity and resistance of earth rods and associated
installations. Supplied in a hard carry case together with
auxiliary stakes and cables.
4 pole earth tester for measuring soil resistivity and resistance
of earth rods and associated installations. Supplied in a hard
carry case together with auxiliary stakes and cables.,An ICLAMP
selective clamp is available separately, and when used with the
DET4TC allows the testing of an earth rod without the need for
disconnection from the system.,A VCLAMP is also available
separately, which when used in conjunction with ICLAMP
allows stakeless measurements to be made in situations where
driving auxiliary stakes is not practical.
Large backlit LCD display, controlled by 2-axis paddle for ease of use.
Results can then be stored together with any relevant notes, for later
download to a PC.
Resistance range 0.01 to 20,000 ohms auto ranging
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Results in less than 3 seconds
Lightweight, easily portable and easy to use
4-wire measurement to null out lead resistance
Auto mode. Connection of handspikes supplied automatically starts
test without the need to press test button
Auto current reversal cancels out standing EMFs
User selectable high and low limits
Memory for up to 700 sets of results complete with notes of up to 200
characters
Keypad for extra data entry
Fuse protected to 600V
NiMH battery reduces weight
Contents:
Heavy duty low resistance ohmmeter combining
rugged construction with accuracy and ease of
use. It features an internal rechargeable battery
Resistance range 0.01 to 20k ohms auto ranging
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and
Tool bag
One 2.5lb (1.1kg) hammer
Four galvanised steel spikes
30m and 50m lengths of cable on a cable-winder
3m leads complete with connectors and clips
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and VCLAMP)
Earth current range (requires ICLAMP)
and can also operate from a mains supply, even if the battery is
completely flat
250mW power limit (with optional override) to avoid heating the test sample
VCLAMP)
Earth current range (requires ICLAMP)
Stock no. Price per OM S$ S$ S$
204-612 unit 1+ 580·00
Supplied with: 2 x spikes, mains charger, car charger and NiMH battery.
Standards: EN61010-1 CAT IV 100V
Standards: EN61010-1 CAT IV 100V
2 high power ( up to 25W) ranges ideal for inductive applications,
and where heating a potential weakness is desirable
7 low power output ranges limited to 0.25W to avoid heating the
test piece and to extend battery life.
Rechargeable battery or line power supply, continuous operation,
even with dead battery
10 A for 60 seconds, less time waiting to cool, great for charging
inductance
High input protection to 600 V, inadvertent connection to line or
UPS voltage will not blow a fuse
Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
Large backlit LCD is clear and easy to read in all lighting conditions.
Rotary switch selects one of five test modes, including auto start on connection, giving ease of use
1·9999Ω 100μΩ ±0·2%±0·2mΩ 20mV 10mA
19·999Ω 1mΩ ±0·2%±2mΩ 20mV 1mA
199·99Ω 10mΩ ±0·2%±20mΩ 20mV 100μA
1999·9Ω 100mΩ ±0·2%±0·2Ω 200mV 100μA
Measurement modes Manual, Auto Continuous, High Power, Unidirectional
Test current accuracy ±10%
Output current stability >10ppm per sec @ 10mA; >100ppm per second @ higher currents
Voltmeter input impedance > 200kΩ
Hum rejection Less than 1% +20 digts additional error with 100mV rms 50/60Hz onpotential leads. If exceeded, a warning lamp will illuminate.
Battery capacity 7Ah NiMH rechargeable battery
Battery life Typically 1000 x 10A tests
Recharging External 115/230Hz charger or 12V car battery
Standard charging rate 4 hours
Quick charging rate 2.5 hours to 90% capacity @ 20°C
Operating temperature +5 → +45 °C full specification; -10 → +50 °C reduced accuracy
Error v. temperature <0·01% per°C over range 5 to 40°C
Standard charge 0 → +45 °C
Fast charge +10 → +45 °C
Safety EN61010-1 600V Category III, (with DH6 handspike set)
Size (HxWxD) & Weight 220 x 100 x 237mm, 2.6kg
Full scale Resolution Accuracy Volts (full scale) Test Current
1·9999mΩ 0·1μΩ ±0·2%±0·2μΩ 20mV 10A
19·999mΩ 1μΩ ±0·2%±2μΩ 20mV 1A
199·99mΩ 10μΩ ±0·2%±20μΩ 20mV 100mA
Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA NiMH rechargeable batteries, hard carry
case, mains charger, quick start guides, user guide on CD
Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA alkaline batteries, hard carry case, quick
start guides, user guide on CD
Stock no. Price per OM S$ S$ S$
410-0110S unit 1+ 8070·00
Resistance range 0.01 to 20kΩ Test frequency Hz 94.105.111 Accuracy 2% ± 3 digits Earth current range with ICLAMP 0.5mA to 19.9A Ingress protection IP54 Display LCD with back light Output ±25V or ±50V Operating temp. -15 → +55 °C
Resistance range: 0.01 to 20,000Ω Earth current range with ICLAMP 0.5mA to 19.9A Accuracy: 2% ± 3 digits Display: LCD with back light Ingress protection: IP54 Operating temp: -15 → +55 °C Output ±25V or ±50V at 128Hz
Support accessories:
Description Stock no. Price per OM S$ S$ S$
DET4 TCR2-RS 489-674S unit 1+ 2000·00
ICLAMP 514-4672 unit 1+ 460·00
DH5 straight duplex handspike set with 2.5m long leads. See stock no. 666-7371
Description Stock no. Price per OM S$ S$ S$
DET4 TC-RS 489-664S unit 1+ 1480·00
VCLAMP 104-767 unit 1+ 415·00
ICLAMP 514-4672 unit 1+ 460·00
Supplied with: DH4 duplex handspikes with 1.2m lead length, test lead pouch (lid mounted) user
guide on CD ,6V 7Ah sealed lead acid battery (fitted)
Test Current Resistance Range Resolution Accuracy * Full scale voltage Max. power output
0.1 mA 0 → 2500.0 Ω 100 mΩ ±0.2% ±200 mΩ 25 mV 2.5 μW
0.1 mA 0 → 250.00 Ω 10 mΩ ±0.2% ±20 mΩ 25 mV 2.5 μW
1 mA 0 → 25.000 Ω 1 mΩ ±0.2% ±2 mΩ 25 mV 25 μW
10 mA 0 → 2500.0 mΩ 100 μΩ ±0.2% ±200 μΩ 25mV 250 μW
100 mA 0 → 250.00 mΩ 10 μΩ ±0.2% ±20 μΩ 25 mV 2.5 mW
1 A 0 → 25.000 mΩ 1 μΩ ±0.2% ±2 μΩ 25 mV 25 mW
10 A 0 → 2500.0 μΩ 0.1 μΩ ±0.2% ±0.2 μΩ 25 mV 0.25 W
1 A 0 → 2500.0 mΩ 100 μΩ ±0.2% ±200 μΩ 2.5 V 2.5 W
10 A 0 → 250.00 mΩ 10 μΩ ±0.2% ±20 μΩ 2.5 V 25 W
* The accuracy stated assumes forward and reverse measurements.Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present
Measurementmodes
Normal, Automatic, Continuous, Inductive, Unidirectional
TemperatureCoefficient
< 0.001% per °C, from 5 °C → 40 °C
Test currentAccuracy
±10%
Voltmeter inputimpedance
>200 kΩ
Noise rejection: <1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads.Warning will show if hum or noiseexceeds this level.
Battery capacity 6V 7AH sealed lead acid
Battery Life 1000 Auto (3 sec) tests
Charging time 8 hours
OperatingTemperature
+5 °C → +45 °C full specification, -10 °C → +50 °C reduced accuracy
Line voltage inputrange
90 → 264 V rms, 9 → 17 VA, 50/60 Hz
Dimensions &Weight:
315 x 285 x 181mm : 6.7kg
Description Stock no. Price per OM S$ S$ S$
DLR010HD 712-5768Sa unit 1+ 6260·00
2247
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
4105A Compact Digital EarthTester
4102A High PerformanceAnalogue Earth Tester
CA 6415 Ground Tester
Fluke 1630 Earth Ground Clamp Meter
CA6250 10A Low ResistanceMicro-ohmmeter
DET14C & DET24C Earth TestClamp
Portable 10A Micro-ohmeter for testing the quality of
mechanically bonded metalwork, contacts and switches,
Dust and Drip Proof
Allows quick checking of earth loops without
disconnecting the earth cable under test
Push button controls for single handed operation
Ground resistance range : 0.050 Ω to 1500 Ω
True RMS Ground leakage current range : 0.2 mA to 35 A
Auto ranging & HOLD function
4 digit plus 6 digit backlit LCD display
High and low resistance alarms
256 test results storage & recall
Real time date & time stamping of results
Oval clamp for easy access to earth cables & earth straps
37mm dia conductor & 50mm earth strap capacity
Low maintenance flat jaw interface
EN61010 Safety rating CATIV 600V
Extended battery life
Dust and drip proof (desgined to IEC60529 IP54)
An earth ground clamp meter to simplify ground loop testing also known as
’stakeless’ earth ground testing with no need for placing earth stakes and
disconnecting the earth system from the electrical installation.The Fluke 1630 is
ideally suited for the following applications:,Ground loop checks on any earthing
system;,Continuity tests on earth bonding circuits and connections;,Inspection of
lightning protection systems.
Precision measurement and test leads for simplified two wire
measuring system supplied as standard accessories
Automatic warning when resistance of auxillary earth spikes is in
excess of tolerance
Small, lightweight and shock resistant
A wide ground loop resistance range, from 0.025Ω to 1500Ω, to satisfy all
requirements
33mm jaw size for tests on ground conductors and/or equipotential bus bars
Measurement of ground leakage current, from 0.2mA to 1000mA, without needing
to disconnect - ideal for system troubleshooting
Wide true RMS ac current measurement range from 0.2A to 30A allows one
instrument for multiple applications
User-defined HI/LO alarm limits, for rapid measurement evaluation
Display-HOLD function to freeze measurements
resistance of cables and heating of motors and transformers.
DET24C Additional Features
0 to 1200Ω measuring range
Measurement of leakage current from 1 to 30mA
Earth “Noise” indicator to maintain highest accuracy
Large 32mm clamp diameter
Sealed flat face jaws for ease of cleaning and reliability
User suitable alarm thresholds
99 measurement capacity
Visual indicators for battery life, Jaws closed and Display
Hold
Precision measurement and two wire measuring system supplied as
accessories
Capable of measuring earth voltage
Recording function for automatic storage of measured values, which can be recalled later on the
LCD display
Automatic self calibration ensures correct measurement every time
Complies with EN61010-1 CAT III 300V
Overload protection: 200 A
Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557
Supplied with: Alkaline battery and carrying case.
Large backlit LCD display
Broad measurement range 1μΩ to 2,500Ω
Temperature compensation of readings to allow for temperature
variations
4 wire measurement with automatic compensation for spurious
voltages
Automatic detection of the presence of external AC or DC voltages
on the terminals to disable measurements where accuracy cannot be
guaranteed
3 measurement modes:
Inductive mode for measurements on inductive components
(transformers, motors, etc.)
Non-inductive mode for measurements on resistances, with a time
≥ 8 hours battery life (continuous operation)
IrDA to USB interface for download
Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557
Resistance 0.1Ω to 1.2kΩ in 7 ranges Alarm Adjustable thresholds from 1 to 199ΩResolution (Ω) 0.01 at 0.1 to1Ω Safety Complies with EN61010-2-032 1500V,
cat III, pollution level 2 Frequency of use(Hz)
2400 Power supply 1 x 9V alkaline or NiCD battery
Current 1 to 300mA; 0.3 to 3.00A; 3 to 30A Size (HxWxD) &Weight
55 x 100 x 235mm, 1kg
Resolution (mA) 1mA @ 3.0mA; 10mA @ 3 to 30A
2000 test results storage
PowerDB LiteTM software
constant of a few ms (contacts, metallization, etc.)
Non-inductive mode with automatic triggering for measurements on resistances with no time
constant
Programmable audible alarm limit
Memory storage of 1,500 measurements
2 wire PT100 temperature probe input
RS232 interface for connection to a PC or printer
Rechargeable NiMH batteries with integral charger
IP64 case (closed); IP53 (open)
Complies with EN61010-1 CAT III, 50V
Supplied with: 9V PP3 battery, carry case, resistance test loop & instructions.
Measurement Ranges
Earth Resistance 20Ω/200Ω/2000ΩEarth Voltage
(50-60Hz) 0-200V AC Accuracy
Earth Resistance equals ±2% rdg ±0.1Ω (20Ω range) equals ±2% rdg ±3 digits (200-2000Ω)
Earth Voltage equals ±1% rdg ±4 digits Power Source R6P (AA) (1.5) x 6 Dimensions (mm) 105 (L) 158 (W) 70 (D) Weight 550g approx.
Measurement Ranges Earth Voltage equals ± 3% of fullscale
Earth Resistance 12Ω/120Ω/1200Ω Power Source R6P (AA) (1.5V) x 6 Earth Voltage (50-60Hz)
0-30V AC Dimensions (mm) 105 (L) 158 (W) 70(D)
Accuracy Weight 600g approx. Earth Resistance equals ± 3% of full
scale
Stock no. Price per OM S$ S$ S$
466-6058 unit 1+ 375·00
Stock no. Price per OM S$ S$ S$
466-6036 unit 1+ 340·00
Stock no. Price per OM S$ S$ S$
375-2574 unit 1+ 2190·00
Supplied with: Carry case, NiMH batteries (fitted), 2m test lead set with Kelvin clips; mains power
lead and instruction manual.
Contact RS for calibration requirements
Supplied with: (DET14C & DET24C):Carry case carry strap , User guide on CD, calibration check
accessory, 4 x AA alkaline batteries.
(DET24C only): USB IrDA dongle, USB lead & PowerDB lite software
Range Resolution Accuracy Test current
5.0000 mΩ 0.1 μΩ 0.15 % + 1.0 μΩ 10 A
25.000 mΩ 1 μΩ 0.05 % + 3 μΩ 10 A
250.00 mΩ 10 μΩ 0.05 % + 30 μΩ 10 A
2500.0 mΩ 0.1 mΩ 0.05 % + 0.3 mΩ 1 A
25.000 Ω 1 mΩ 0.05 % + 3 mΩ 100 mA
250.00 Ω 10 mΩ 0.05 % + 30 mΩ 10 mA
2500.0 Ω 100 mΩ 0.5 % + 300 mΩ 1 mA
Power 5 off D cell (8.5Ah) NiMH rechargeable batteries ;typical life 5000 Hours ( 10A test)
Charger supply 90 to 264V @ 45 to 420Hz
Dimensions 270 x 250 x 180 mm
Weight 4kg
Range Resolution
Resistance 0.025 to 1500 Ω 0.002 Ω to 20 Ω
Current 0.2 to 35A 0.01A
Leakage current 0.3 to 1000 mA 0.001mA to 1mA
Continuity Buzzer <40Ω approx
Dimensions & Weight 257 x 100 x 47mm: 640g
Battery 9V alkaline PP3 (supplied)
Battery life ≥8 hours (continuous operation)
Resistance Measurement 0.05Ω (±1.5% ± 0.05Ω) to 1500Ω (±35%) in 8 ranges
Current Measurement 0.200 mA (± 2.0% ± 0.05 mA) to 35.0 A (± 2.0% ± 0.1 A) in 6 ranges
Battery life 24 hours continuous @ 25Ω
Operating temperature -20 °C → +55 °C
Dimensions & Weight 248 x 114 x 49 mm, 960g
Stock no. Price per OM S$ S$ S$
712-5967S unit 1+ 2521·00
Stock no. Price per OM S$ S$ S$
236-571 unit 1+ 5380·00
Description Stock no. Price per OM S$ S$ S$
DET14C 705-9422S unit 1+ 1710·00
DET24C 705-9431S unit 1+ 1980·00
2248
www.nguyenxuong.com
AC Current Clampmeters
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
ICM A5 Electrical Tester withNon Contact Voltage Detector
ICM A7D Electrical Tester
IEK 10 Digital Multimeter withCurrent Clamp
Fluke 365
4200 Earth Clamp Tester
Fluke T5-600 & T5-1000 Multi-function
Backlit LCD display with display HOLD
Detachable compact jaw head for easy access to tightly
packed wires
Compact design fits in the hand and can be used while
wearing personal protective equipment.
200 A ac (true rms) and dc current measurement with
fixed jaw
600 V ac (true rms) and dc voltage measurement
Resistance & continuity measurement
CAT.IV Clamp Meters can measure voltages and
currents in both very low and high power circuits
Multiple Earthing System allows earth resistance
2000 count large LCD display
Slim line electrical tester to check voltage, resistance, continuity and current. The
integral non contact ac voltage detector enables fast identification of the presence of
mains voltages. The open jaw current clamp enables safe, non intrusive measurement
of ac currents up to 200A.
Current, Voltage and Continuity/ResistanceTesters
300Aac non-intrusive current measuring
Voltage measurement to 600Vac/dc
Ohms ranges from 300Ω to 30MΩ
3200 count display (0.1mV resolution at 300.V)
65 segment analogue bar graph
Innovative open jaw technology
200A (ac) measurement capability
600V dc/ac voltage measurement
2000Ω resistance range
Continuity bleeper
Display HOLD function
Auto power off
4mm plug in lead set allows replacement or connection of fused test leads
Safety to EN61010-01 600V CAT III for industrial environments
from 0.05 to 1200Ω to be measured without the auxiliary earth spikes
Accurate true RMS readings of AC current including distorted waveform
from 1mA to 30A
Noise Check Function detects current, which occurs during earth
resistance measurements and display ""NOISE"" mark on the LCD
Memory function allows saves and displays up to 100 measurement data
Data hold / Buzzer / Back light / Over-range indication functions
Applications include power distribution, power utilities and maintenance
fields
Mains proof ohms ranges
Fast continuity beeper
Diode test capability
Data hold function to freeze display
600V protection in every range
Auto power off
2000 counts large LCD display
Open jaw technology – 16mm dia. conductor size
200A ac measurement capability
750V ac/ 1000Vdc measurement range
Integral non-contact AC voltage detector with visual & audible indication
20MΩ resistance range
Continuity and Diode Test
Display hold
Auto–power off
Conforms to EN61010-1 (safety rating) CAT IV 600V, CAT III 1000V
Automatically measures AC & DC volts
Displays resistance up to 1000Ω
Easy and accurate OpenJaw� current measurement
Continuity beeper
Compact design with probe storage
Detachable probe tips
Protected to 600V (T5-600) and 1000V (T5-1000) for use in
CAT III environments
Power from 2 x AA cell
Auto switch-off
Built in flashlight for illumination and identification of wires
CAT III 600V safety rating.
State of the art signal processing allows for use in noisy electrical environments while providing
stable readings
Contact RS for calibration requirements
Supplied with: PP3 9V alkaline battery, users instructions & test leads.
Supplied with: Instructions, test lead set and 9V PP3 battery.
Supplied with: Soft carry case, 2 AAA alkaline batteries & instructions
Supplied with: IDM17 probe multimeter with 2xAAA alkaline batteries fitted, ICA15 current adaptor,
test lead set, operator’s manual, soft carry case.
Note: Only for multiple earth point systems only; single earth can not be
measured
Standards: IEC 61010-1 : 2001 (CAT.IV 300V Pollution degree2)
DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Lowest Range Resolution 0.1V DC Voltage Lowest Range 200V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Highest Range 600V Resistance Lowest Range 200ΩDC Voltage Lowest Range Resolution 0.1V Resistance Highest Range 20MΩ
AC Voltage Accuracy (45 to 60 Hz) ± (1.5% rdg + 3d) Resistance Lowest Range Resolution 0.1ΩAC Voltage Lowest Range 200V Dimensions & weight 185mm x 50mm x
35mm; 170g AC Voltage Highest Range 750V
Note: Please contact RS for calibration requirements
Current range 0.1 to 300A Accuracy ±(1.7%+5d) at 40 to 500Hz Accuracy ± (1.9%+0.5A) at 50 to 60Hz Resistance ranges 300Ω to 30.0MΩ
Max. cable size 29mm diameter Accuracy from ±(1%+2d) to ±(3%+5d) d.c. voltage range 300mV to 600V Safety
specification Designed to meet IEC 61010-1,Installation Category III 300V
Accuracy ±(0.7%+2d) Size (HxWxD) &Weight
102 x 72 x 36mm, 150g
a.c. voltageranges
300mV to 600V
AC Voltage 600V AC Accuracy ± (3% + 3 digits) AC Accuracy ± (1.5% + 3 digits) Ohms 2000ΩDC Voltage 600V Ohms Accuracy ± (1% + 2 digits) DC Accuracy ± (1% + 2 digits) Continuity Beeper 25 Ω beep on/ >300 Ω beep off AC Current 200A Size (HxWxD) & Weight 84 x 175 x 31mm, 280g
Note: T5 accessory kit available containing TP220 test probes, AC285 alligator clips, C33 soft zippered
case
Stock no. Price per OM S$ S$ S$
697-3989 unit 1+ 145·50
Measurement Range Resolution Accuracy
AC & DC Current 200 A 0.1 A ± (2% + 5d )
AC & DC Voltage 600 V 0.1 V ± (2% + 5d )
Resistance 6000 Ω 0.1 Ω ± (1% + 5d )
Jaw capacity 17mm ∅
Stock no. Price per OM S$ S$ S$
697-4064S unit 1+ 158·00
Stock no. Price per OM S$ S$ S$
697-3991 unit 1+ 139·50
Supplied with: Hard carry case & batteries
T5-600 T5-1000
AC voltage 600V rms 1000V rms
AC voltage accuracy ± (1.5% +2 digits) ± (1.5% +2 digits)
DC voltage 600V 1000V
DC voltage accuracy ± (1% + 1 digit) ± (1% + 1 digit)
AC current 100A 100A
AC current accuracy ± (3% + 3 digits) ± (3% + 3 digits)
Ohms 1000 ohms 1000 ohms
Ohms accuracy ± (1% + 2 digits) ± (1% + 2 digits)
Input impedance V ac/dc 1Mohm >100pf 1Mohm >100pf
Ohms <2.6kOhm <2.6kOhm
Safety IEC1010 CAT III 600V IEC1010 CAT III 1000V
Battery life 400 hrs typical 400 hrs typical
Size (HxWxD) & Weight 31 x 51 x 203mm, 300g 31 x 51 x 203mm, 300g
Description Stock no. Price per OM S$ S$ S$
T5-600 291-9372S unit 1+ 173·00
T5-1000 292-1230S unit 1+ 234·00
AC Current 100mA - 30A Earth Resistance (Autorange)
200 - 1200Ω
Operating System Earth resistance function : Constant voltage injection, Current detection, (Frequency : Approx.2400Hz) Dual Integration AC current function : Successive Approximation
Response Time Approx.7 seconds (Earth resistance), Approx.2 seconds (AC current) Sample Rate Approx. 1 times per second Current Consumption Approx. 50mA (max. 100mA) Withstand Voltage AC5320Vrms / 5 seconds, Between the Transformer jaws fitted parts and Case enclosure
(except for jaws) Dimensions 246(L) × 120(W) × 54(D)mm Weight 780g
Type Clampmeter Maximum Jaw Capacity ∅ 17 mmMaximum Current 200 A Maximum dc Voltage 600 VMaximum Voltage 600 V
Accessories
Stock no. Price per OM S$ S$ S$
255-033 unit 1+ 1130·00
Description Stock no. Price per OM S$ S$ S$
Fluke 365 705-1941S unit 1+ 431·00
Description Stock no. Price per OM S$ S$ S$
AC285 Large Alligator Clips 451-1431 unit 1+ 36·40
Holster T5-600/T5-1000 292-1246 unit 1+ 49·90
2249
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
ICM20 Digital Current Clamp
Multimeter Test Leads
ICM3090 Digital Clamp Meters
ICM33 II and ICM33R II DigitalClamp Meters
Fluke 333, 334 and 335
www.rssingapore.com
ICM 134 HVAC CurrentClampmeter
ICM A6 Automatic ElectricalTester, 600A
AC current clamp designed for safe, non-intrusive AC current
Replacement test leads to suit ISO–TECH and most other
digital multimeters. Fitted with right-angled 4mm shrouded
plugs and supplied with probe tip insulators to prevent
accidental short circuits and a pair of crocodile clips.,Probes
designed to meet BS EN 61010-1 (safety standard) 1000V Cat
III.,Current rating 10A.
Two clamp multimeters able to measure ac current up to 600A, ICM33R II has true rms
reading in AC current and AC voltage measurement.
Fully automatic intelligent tester that selects the measuring function dependant on
input terminal and current clamp conditions. No range of function selection is
necessary by the user. The priority is AC voltage, DC voltage, resistance then AC
current.
Three clamp meters designed to measure AC current, AC/DC voltage and
resistance.
A clamp multimeter designed to measure AC currents up to
Featuring current clamp, multimeter and thermometer functions the ICM134 is ideally
suited to HVAC and electrical maintenance applications up to 600A ac.
3 1/2 2000 count LCD
600V ac voltage measurement
2000Ω resistance range
Continuity beeper for <50Ω
Display hold
600V circuit protection
34 mm conductor jaw capacity
Powered by 1x alkaline PP3 battery (supplied)
Safety to EN 61010-1 CAT III 600V
Rugged construction with fire retardant, high-impact plastic case
4000 count large backlit LCD display
750V ac / 1000dc voltage measurement
600A ac current measurement
4000μA dc current measurement ideal for flame sensor testing
40MΩ resistance measurement.
4mF capacitance measurement
-40 °C to 400 °C type K thermocouple temperature measurement input & sensor
Continuity & diode test
Display hold function
32mm conductor jaw size
Complies with IEC 61010-1 CAT III 600V, CAT II 1000V
400A, including ac/dc voltage and resistance measurement.
600V a.c./d.c. voltage measurement
Continuity beeper below 30Ω
Auto shut-off to maximise battery life
Display hold keeps measurements on the display
Ergonomic control layout
30mm jaws
Lightweight design
Safety rating IEC 1010-2-032 (safety standard) Cat III 600V
Type Test Lead Connection Type Shrouded Right Angle Plug
measurement upto 400 Amps
10000 counts LCD display with annunciators
Auto sensing on ACV, DCV, Ω, ACA
600A ac measurement capability
750V ac/ 1000Vdc measurement range
2kΩ resistance range
Continuity and Diode Test
32mm conductor jaw capacity
Display hold
Auto–power off
Conforms to EN61010-1 (safety rating) CAT IV 600V, CAT III 1000V
3 3⁄4 digit LCD, 4000 count display
Auto-ranging
Convenient pocket size
40, 400Aac current measuring ranges
2% basic AC current accuracy
600Vac/dc voltage measurement
400Ω resistance range with continuity beeper below 40Ω
Data hold function
27mm conductor jaw capacity
Auto power-off
Powered by 2x AAA alkaline cells (supplied)
Safety to EN61010 - 1 CATIII 300V, CATII 600V
Description Stock no. Price per OM S$ S$ S$
Test leads 243-2998 unit 1+ 27·90
334 Additional Features:
Supplied with: 9V battery, carry case, test leads, type K thermocouple adaptor and
2000 count Large-scale LCD display
AC current measuring up to 400 Amps
Data Hold
Max Hold
Easy battery replacement
27mm dia. conductor size
1.2m Drop Proof
Auto power off to maximise battery life
Safety to EN61010-1 CAT. III 600V
Supplied with: Carrying case, test leads, 9V PP3 battery.
Supplied with: carry case, 2 x AA batteries, users instructions & test leads.
Back-lit display
In-rush current measurement
DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Range Resolution 0.1V DC Voltage Range 1.5V to 999V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Lowest Range Resolution 0.1V Resistance Range 2000Ω
AC Voltage Accuracy (50 to 500 Hz) ±(1.5% rdg + 3d) Resistance Range Resolution 0.1ΩAC Voltage Range 1.0V to 750V Dimensions & weight 200mm x 83mm x 40mm; 395g
Range/Resolution Accuracy
AC current 200A / 0.1A600A/1A
± 1.9% +5d, 50 to 60Hz±1.5% +5d (0 to 400A) 50-60Hz±2.5% +5d (400 to 600A) 50-60Hz
AC voltage 600V / 1V ±1.2% +3d 40Hz to 500Hz
Resistance 200Ω / 1Ω ±1.5% rdg +2dgt
Size (HxWxD) & Weight 200 x 76 x 41mm, 360g
type K bead sensor, users manual, vinyl belt pouch.
Supplied with: PP3 battery (installed), Manual, and Carrying case
Supplied with: Test leads, carry case, batteries.
Description Stock no. Price per OM S$ S$ S$
ICM A6 697-3998 unit 1+ 175·00
335 Additional Features:AC Current Range (50 - 60Hz) 20.0A 200.0A 400A Basic Accuracy (50 - 60Hz) ±(3.0%+0.05A) ±(2.0%+0.5A) ±(2.0%+5A) Conversion Type Average sensing Maximum Conductor Size 27mm dia Battery Life 200 hours typical Size (HxWxD) & Weight 56 x 180 x 32mm (WxLxH), 250g
Range Resolution Accuracy Frequency
Range
AC Current 40A 0.01A ± (2% reading + 10 digits) 50/60Hz
400A 0.1A ± (2% reading + 10 digits) 50/60Hz
DC Voltage 400V 0.1V ± (1% reading + 5 digits) –
600V 1V ± (1% reading + 5 digits) –
AC Voltage 400V 0.1V ± (1.5% reading + 10 digits) 40 - 600Hz
600V 1V ± (1.5% reading + 10 digits) 40 - 600Hz
Resistance 400Ω 0.1Ω ± (1% reading + 5 digits) –
Size (HxWxD) & Weight 192 x 64 x 31mm, 250g
Range Accuracy Resolution
Volts DC 4 to 1000V ±(0.9% + 2d) 1mV
Volts AC 4 to 750V ±(1.5% + 5d) 1mV
Current AC 0 to 600A ±(1.9% + 1A) 0.1A
Current DC 0 to 4000μA ±(1% + 2d) 0.1μA
Resistance 0 to 40MΩ ±(0.7% + 2d) 0.1Ω
Temperature -10 to 400 °C ±(1% + 4 °C) 0.1 °C
Capacitance 4nF to 4000μF ±(2.0% + 8d) 1pF
Continuity <=30Ω
Maximum jaw capacity 32mm
Dimensions & weight 212 x 84 x 40 mm, 390g
Description Stock no. Price per OM S$ S$ S$
ICM33 II 697-3976 unit 1+ 186·00
ICM33R II 697-3979 unit 1+ 205·00
Stock no. Price per OM S$ S$ S$
697-3960 unit 1+ 105·50
Stock no. Price per OM S$ S$ S$
697-3954 unit 1+ 235·00
True rms current measurement
Back-lit display
In-rush current measurement
Stock no. Price per OM S$ S$ S$
697-3709 unit 1+ 149·50
Supplied with: TL 75 test leads, soft carry case, 2 x AA batteries.
Contact RS for calibration requirements
Accessories
Description Stock no. Price per OM S$ S$ S$
H3 Holster 410-1242 unit 1+ 53·70
2250
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
Kyoritsu 2017 Digital AC Clamp Meter
Kyoritsu 2007A Clamp Meter
Kyoritsu 2002 PA Clamp Meter0 to 2000A
ICM133R 1000A ac,True-rmsreading
ICM135R 600A ac,True-rmsreading
Fluke 373
F3N True rms Clampmeter
Tear drop shaped jaws for use in tight spaces
Large backlit display
600 A ac current measurement with fixed jaws
600 V ac (true rms) and dc voltage measurement
Capacitance, resistance and continuity measurement
Display HOLD
CAT IV 300V, CAT III 600 V safety rating
Standards: IEC 61010-1 CAT III 600V, IEC 61010-2-031, IEC 61010-2-032
1000A ac current measurement
750Vac / 1000Vdc voltage measurement
Large 51mm dia. conductor jaw capacity
4000 count backlit digital display with analogue bargraph
True RMS reading on AC mode
Resistance & continuity beeper <30Ω
Display Hold & Min Max Function
10ms Peak Hold on ac A & ac V
Frequency Counter
Auto Power Off (30 minutes)
Separate battery compartment
600V circuit protection
Complies with EN61010 CAT. III 600V Safety Standard for industrial applications
Rugged construction with flame retardant, high impact plastic
This is a 700A ac general purpose current clamp meter
which is also able for measure current and frequency on
variable speed drives, switching power supplies and other
600A ac measurement
600V ac/dc voltage measurement
34mm dia. conductor jaw capacity
4000 count backlit LCD display with analogue bargraph
True RMS reading on AC mode
Resistance & continuity beeper <30Ω
Display Hold & Min Max Function
10ms Peak Hold on ac A & ac V
Frequency Counter
Auto Power Off (30 minutes)
Separate battery compartment
600V circuit protection
Complies with EN61010 CAT. III 600V Safety Standard for industrial applications
Digital display with maximum 4000 counts
Tear-drop shaped jaws for use in confined spaces
Data hold function
Sleep function to save battery
Standards: IEC61010-1CAT.III 300V; IEC61010-1CAT.II 600V;IEC61010-1CAT.I 1000V; IEC61010-2-031; IEC61010-2-032;IEC61326(EMC)
Terminal cover to avoid the use of incorrect terminals
Peak function to measure current peaks
Supplied with: Soft carry case, 2 x AA alkaline batteries and instructions
complex loads. Because of its unique set of functions the F3N
can be used for a wide range of power electronic applications:
measurement of peak motor start currents to determine the crest
factor, estimation of the harmonic content of a signal, recording
average consumption over a 24 hour (or other) period or check
for imbalances in motors, checking variable speed drives and
generator sets, etc.
Tear drop shaped jaws for ease of use in crowded
cable areas
Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.
Note: Colour may differ from that shown.
AC Current 400/600A±1.5% rdg ±4 dgt (50/60Hz)±2% rdg ±5 dgt (40∼400Hz)
AC Voltage 400/750V±1.2% rdg ±3dgt [50/60Hz]±1.5% rdg ±4dgt [40∼400Hz]
Resistance 400/4000Ω ±1.5% rdg ±2dgt Frequency Response 40Hz-400Hz Continuity Check buzzer sounds below 50Ω±35ΩConductor Size ∅33mm max. Withstand Voltage 3700V AC for 1 minute Dimensions 195(L) × 78(W) × 36(D)mm Weight 260g
Three functions of AC current, AC voltage & resistance
4-digit 10,000 count display with bar graph
True rms reading with crest factor capability of 5
Frequency measurement from 0.5Hz to 10kHz
Peak (2ms) mode enables measurement of half cycle peak
current values
Smooth mode averages last 3 readings to reduce display
Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.
ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 750V Resistance
Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)
50 to 500Hz Resolution 0.1Ω
dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 1000V Frequency counter
Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 1000A Size (WxHxD) and Weight 90 x 275 x 51mm, 420g Resolution 0.1A & 1A
Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032
Note: Please contact RS for calibration requirements
AC A 400/2000A Conductor Size ∅55mm max. AC V 40/400/750V Power Source R6P(AA) (1.5V) x 2 approx. DC V 40/400/1000V 150 hours continuous use
400Ω/4k/40k/400k Ω Dimensions (mm) 247 (L) 105 (W) 49 (D) Continuity 400Ω Weight 470g approx. Output Voltage 400/2000A DC 400mV/200mV
Measurement Range Resolution Accuracy
AC Current 600 A 0.1 A 2% ± 5 digits
AC Voltage 600 V 0.1 V 1.5% ± 5 digits
DC Voltage 600 V 0.1 V 1% ± 5 digits
Resistance 6000 Ω 0.1 Ω 1% ± 5 digits
Capacitance 1000 μF 1 μF 1.9% ± 2 digits
Fixed jaw capacity 32mm diameter (750 MCM)
Stock no. Price per OM S$ S$ S$
255-027 unit 1+ 91·50
flicker on both current and frequency
Record mode allows the max., min. and average current or frequency to be displayed
Live bar graph displays the current whatever the operating mode
Designed to meet IEC 1010 600V CAT III safety standards
Stock no. Price per OM S$ S$ S$
697-3945 unit 1+ 265·00
ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 600V Resistance
Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)
50 to 500Hz Resolution 0.1Ω
dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 600V Frequency counter
Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 600A Size (WxHxD) and Weight 76 x 220 x 50mm, 360g Resolution 0.1A & 1A AC A 200/600A
AC V 200/600V
Ω 200Ω buzzer sounds below 30 ±20Ω
Conductor size ∅33mm max.
Frequency Response 45Hz to 1kHz
Power Source 6F22 (9V) x 1
Dimensions (mm) 208 (L) 91 (W) 40 (D)
Weight 400g approx.
Stock no. Price per OM S$ S$ S$
420-0737 unit 1+ 270·00
Description Stock no. Price per OM S$ S$ S$
Fluke 373 705-1948S unit 1+ 328·00
Supplied with: Alkaline 9V PP3 battery (fitted), instruction manual, carrying holster with belt clip.
Stock no. Price per OM S$ S$ S$
697-3957 unit 1+ 215·00
Manu. Part
No.
Stock no. Price
per
OM S$ S$ S$
2017 420-1061 unit 1+ 117·00
Measuring range 0.3A to 400A trms (700A for sine) Accuracy 400A range ±5% of reading (400 - 700A) Range overload limits 700A rms or 1000A crest Frequency Current measurement 10Hz to 1kHz
Frequency measurement 0.5Hz to10kHz
Accuracy 40A range ±(2% rdg +20 digits) Crest factor 2.5 max. at 400A at 45 to 65Hz 5 max. at 40A at 45 to 65Hz
Accuracy 400A range ±2% of reading (<400A) Size (WxHxD) andweight
98 x 232 x 44mm, 500g
Stock no. Price per OM S$ S$ S$
206-624 unit 1+ 630·00
2251
www.nguyenxuong.com
Leakage Current Clampmeters
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
Sanwa DCM60L
AVO DCM 300E
ISO-TECH ILCM03
Fluke 360 AC Leakage Current ClampMeter
Kyoritsu 2413R True RMS
Kyoritsu 2431
Kyoritsu 2027 Digital ClampMeter True RMS
Kyoritsu 2031 Compact ACCurrent
A 3 1⁄2 digit ac hand held ac clamp meter offering a cost
effective solution for general purpose use. External test
leads are supplied for use where direct measurements are
required.
Compact, light weight and easy-to-use
Rotary switch for easy one finger power-on and
range selection
Large 4000 count 3 3⁄4 digit LCD with analogue bar graph
40mA, 400mA, 4A, 40A, 100A measuring ranges
10μA ultra high resolution
30mm diameter conductor jaw capacity
400Vac voltage range
400Ω resistance and continuity range with beeper below
Large 68mm capacity jaws enable clamping of all
three or four wires of 3-phase systems for leakage
current measurement.
Tear drop shaped jaws for ease of use in confined spaces
Non-invasive measurement of leakage current with 3 mA range and 1 μA of
resolution, for accurate monitoring of insulation erosion
Advanced shielding to ensure accurate results when measuring near other
conductors
Automatic ranging within the manually selected mA or A range
3200 count LCD and bargraph display with wide display angle for easily viewing
measurements
Display-HOLD for convenience when measuring in hard to see locations
Broad range of measurements currents up to 60 A for all installation needs
Easy carrying, pocket sized clamp fits into tight spaces
40mm jaw size
Auto power off with audible warning buzzer
Complies with EN61010 -1 CAT II 300V
Perfect fit to the palm of your hand
3 1⁄2 digit compact design
25mm clamp diameter
Data hold function
IEC 1010 CAT II 600V, CE mark
Sensitve 20mA range has resolution of 0.01mA
Teardrop shaped jaws for use in confined spaces
Frequency filter to eliminate the effect of harmonics
Auto power-off function (automatically turns off after 10
minutes)
Measures from mA up to 1000A
True RMS readings give accurate measurements of distorted waveforms.
Switchable frequency filter to eliminate the effect of the harmonics.
2-way analogue output terminal: Measured AC current is converted to AC
and DC output voltage.
Peak hold function (Selectable 10 or 100ms response time)
Data hold function allows easy reading in dimly lit or hard-to-reach locations
LCD back-light facility (Defaults to "off")
Data hold function
Auto-power off
True RMS sensing
Supplied with: carry case, 3V Lithium battery & instruction manual.
40Ω
Auto power off selectable
Max./min. function
Zero/relative value function
Data hold function
Safety to EN61010 CAT III 300V
Fully IEC1010-1 and IEC101-2-032
compliant for circuits up to 500V
phase to phase or 300V phase to earth
CAT III or 600V CAT II
Continuity buzzer
Contact RS for calibration requirements
Standards: IEC61010-1 CAT.III 300V, IEC61010-2-032
Standards: IEC 61010-1 CAT III 600V, IEC 61010-2-031, IEC 61010-2-032
Standards: IEC61010-1 CAT.III 300V Pollution degree 2, IEC61010-2-032
Supplied with: Carrying case, 2 AAA batteries
Standards: IEC 61010-1 CAT III 300V
AC A 20/200A Power Source 1.5V button cell x2 type LR-44 Conductor Size ∅24mm max. Dimensions (mm) 147 (L) 58.5 (W) 26 (D) Frequency response 50Hz to 1kHz Weight 100g approx. Withstand Voltage 3700V AC for 1 minute
Function Range Ohms 0.1 to 200Ω
ac Voltage (Autorange) 0.1 to 200V and 1 to 600V Continuity Approx. 100Ω
ac Current (Autorange) 0.1 to 200A and 1 to 600A
Supplied with: Carry case, battery and instruction manual
30mA and 300mA ranges for leakage current
measurement
0.01mA resolution on 30mA range
30A and 300A ranges for power measurements
Data hold facility
Maximum conductor size 40mm diameter
3200 count LCD display with analogue bar graph
Range Resolution Accuracy
AC Current 50-60Hz 40Hz-1kHz 40mA 10μA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 400mA 100μA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 4A 1mA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 40A 10mA ±(1.5% rdg + 3d) ±(2% rdg + 5d) 100A 100mA ±(2.2% rdg + 5d)* ±(2.5% rdg + 5d)* AC Voltage
400V 0.1V ±(1% rdg + 3d) ±(2% rdg + 4d) Resistance
400Ω 0.1Ω ±(1% rdg + 3d) Size (HxWxD) and Weight 210 x 62 x 36mm, 200g
* Specified accuracy applies only up to 80A
Function Range Resolution Accuracy
Current AC 50/60 Hz 3mA30mA30A60A
0.001mA0.01mA0.01A0.1A
±(1% + 5d)±(1% + 5d)±(1% + 5d) (0 ∼ 50A)±(5% + 5d) (50∼60A)
Battery life 90 hours approx (continuous use)
Dimensions & weight 176mm x 70mm x 25mm : 220g
Supplied with: Carry case, 2 x LR-44 battery and instruction
AC A 200/600A (True RMS) Frequency Response 40Hz to 1kHz AC V 200/600V (True RMS) Power Source 6F22 (9V) x 1 Ω 200Ω buzzer sounds below 30 ±20Ω Dimensions (mm) 208 (L) 91 (W) 40 (D) Conductor Size ∅33mm max. Weight 400g approx.
Supplied with: Batteries, instruction manual, carrying case.
manual
Stock no. Price per OM S$ S$ S$
420-1055 unit 1+ 137·00
Stock no. Price per OM S$ S$ S$
384-1270 unit 1+ 113·00
Technical Specification - Ranges and Accuracy
Range Accuracy, filter "50-60Hz" Accuracy, filter "Wide" Accuracy, filter "Wide"
50/60Hz input 50/60Hz input 40-1000Hz input
200mA, 2A, 20A ± (2.5% reading + 5 digits) ± (1.8% reading + 5 digits) ± (3% reading + 5 digits)
200A, 1000A (<500A) ± (3% reading + 5 digits) ± (2% reading + 5 digits) ± (3.5% reading + 5 digits)
1000A (>500A) ± 5.5% reading ± 5% reading
Stock no. Price per OM S$ S$ S$
252-191S unit 1+ 1190·00
Stock no. Price per OM S$ S$ S$
697-3721 unit 1+ 530·00
Stock no. Price per OM S$ S$ S$
420-1077 unit 1+ 158·50
Conductor Size Ø 68mm max. Crest Factor 3.0 or less Frequency Response40Hz - 1kHz Withstand Voltage 3700Vac for 1 minute Measurementmethod
True RMS Power Source 6F22 (9V PP3) Opearting life approx. 60hours
Analogue Output 200mV ac/dc for full scale (2000-count)reading
Size (LxWxD) andWeight
250 × 130 × 50mm, approx 600 g
ac leakage current (mA) 30 & 300 Accuracy ±(1.2% rdg +5 digits) 0-200A±(5% rdg +5 digits) 300A
ac current (A) 30 & 300 Power 2 x 1.5 V Button Cells LR44 or SR44 Resolution 0.01mA (30/300mA range)
0.01A (30/300A range) Size (HxWxD) and Weight 176 x 64 x 23mm, 125g
Technical Specification - Ranges and Accuracy
Range Accuracy, filter ’’50-60Hz’’ Accuracy, filter "Wide’’ Accuracy, filter "Wide"
50/60Hz input 50/60Hz input 40-400Hz input
20mA, 200mA, 200A (<100A) ± (3% reading + 5 digits) ± (2% reading + 4 digits) ± (5% reading + 6 digits)
200A (>100A) ± (5% reading + 5 digits) ± (5% reading + 4 digits) –
Stock no. Price per OM S$ S$ S$
543-847 unit 1+ 980·00
Conductor Size Ø 24mm max. Measurement method Average value Frequency Response 40 - 400Hz Effect of external stray magnetic field Ø15mm @ 100A 10mA AC max. Withstand Voltage 3700V AC for 1 minute Power Source 2 × LR44 (1.5V button cell) Size (LxWxD) and Weight 149 × 60 × 26mm, approx. 120 g
Stock no. Price per OM S$ S$ S$
247-0142S unit 1+ 910·00
Stock no. Price per OM S$ S$ S$
543-295 unit 1+ 530·00
2252
www.nguyenxuong.com
AC & DC Digital Clampmeters
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
Fluke 374 and 375
ICM 36R
ICM 136R (true r.m.s. reading)
ICM30 & ICM30R
Kew 5000 & 5001 Data Loggers
A current clamp using Hall effect technology to measure a.c.
Leakage current data logger with 3 input channels and ability to record
continuously for up to 25 days (40 days with model 5001)
Clamp multimeter utilising Hall effect technology and nickel
Measure a.c. and d.c. current up to 300A.
Large backlit display
600 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with optional iFlex flexible current probe
600 V ac (true rms) and dc voltage measurement
Capacitance, resistance and continuity measurement
Display HOLD, Min, max, average and inrush recording
CAT IV 600V, CAT III 1000 V safety rating
Hall effect technology
Auto-ranging
4000 cound LCD display
Continuity beeper
Auto-zeroing key for d.c. current range
375 additional feature
and d.c. current up to 600A.
steel alloy jaws for precise measurement of ac and dc current up to 600A.
True RMS measurement of leakage current
Data is stored in non-volatile memory ensuring retention even after battery
exhaustion
4-stage display of remaining battery life
Information such as present time, recording interval, start of recording and
recording method can be set by using supplied software
Selection of one-time or endless logging modes*
Recall function - Latest 10 sets of data can be checked
Recorded data can be transfered to PC via USB link
Supplied "KEW LOG soft 2" software allows graphing and processing of data
on PC
True rms reading in ac current measurement
2000 count LCD display
Jaw capacity up to 34mm diameter or 20 × 40 mm conductor
Zero adjust knob for d.c. ranges
Display hold function
Auto power down to conserve battery life
Designed to meet IEC 61010-01 (safety standard) 300V Cat III pollution degree 2
Data hold function
MAX hold function
600V protection in every range
Auto power off selectable
* One time mode: Recording stops when the memory is full, Endless mode:
oldest data overwriten by latest data
500mV dc measurement range to interface with other accessories
Frequency measurement
Low pass filter for stable readings in noisy environments
Backlit 4000 count LCD display with analogue bargraph
True r.m.s. reading on ac mode
600A ac/dc current measurement
600V ac/dc voltage measurement
Resistance measurement with continuity beeper
Display hold & peak hold (10ms)
Maximum Conduct Size of 35mm diameter
Maximum Busbar Size: 40×15mm
DCA zeroing key
Min/max function
Frequency counter
Auto power off
Supplied with: Soft carry case, 2 x AA alkaline batteries and instructions
ICM30R has true rms reading in both a.c. current and a.c. voltage measurement.
Standards: EN61010 CAT. III 600V
Note: Kew 8481 current clamp (547-865) must be purchased separately
Supplied with: deluxe carrying case, alkaline PP3 battery (fitted) and instruction
booklet.
Supplied with: Test leads, battery, carry case and instructions
Note: Please contact RS for calibration requirements
Dual Hall sensor nickel-steel alloy jaw mechanism
1.0% basic dc/ac current accuracy
22mm diameter conductor jaw capacity
Safety to EN 61010-1 CAT III 300V, CAT II 600V
Maximum a.c. Current (A) 600 Resolution d.c. Current (mA) 100 Resolution a.c. Current (A) 0.1 Basic Accuracy d.c. Current ± 1.9% Rdg +2 digits Basic Accuracy a.c. Current ±1.5% rdg +5 digits Size (HxWxD) and Weight 203 x 81 x 39mm,
310g Maximum d.c. Current (A) 600
Supplied with: Manual, LR6 alkaline battery, software, USB cable & portable case
Stock no. Price per OM S$ S$ S$
697-3982 unit 1+ 240·00
Range Resolution Accuracy
AC Current 400A 0.1A ±(1.9% rdg + 5d) 50-60Hz 600A 1A ±(1.9% rdg + 5d) 50-60Hz
AC Voltage 400V 0.1V ±(1% rdg + 5d) 50-500Hz 600V 1V ±(1% rdg + 5d) 50-500Hz
DC Current 400A 0.1A ±(1.5% rdg + 5d) 600A 1A ±(1.5% rdg + 5d)
DC Voltage 400V 0.1V ±(0.7% rdg + 2d) 600V 1V ±(0.7% rdg + 2d)
Resistance 400Ω 0.1Ω ±(1% rdg + 3d) Frequency 4kHz 1Hz ±(0.1% rdg + 2d) Size (HxWxD) and Weight 235 x 88 x 52mm, 280g
Note: Colour may differ from that shown.
Standards: IEC 61010-1:2001 CAT.III 300V Pollution degree 2, IEC 61326 (EMC Standard)
Measurement Range Resolution Accuracy
AC Current via Jaw 600 A 0.1 A ± (2% + 5 d)
AC Current via iFlex (optional) 2500 A 0.1 A ± (3% + 5 d)
DC Current 600 A 0.1 A ± (2% + 5 d)
AC Voltage 600 V 0.1 V ± (1.5% + 5 d)
DC Voltage 600 V 0.1 V (374)0.1 mV (375)
± (1% + 5 d)
Resistance 6000 Ω (374)60000 Ω (375)
0.1 Ω ± (1% + 5 d)
Frequency (375 only) 500 Hz 0.1 Hz ± (0.5% + 5 d)
Capacitance 1000 μF 1 μF ± (1% + 4 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)
Description Stock no. Price per OM S$ S$ S$
Fluke 374 705-1939S unit 1+ 466·00
Fluke 375 705-1935S unit 1+ 535·00
Stock no. Price per OM S$ S$ S$
697-3932 unit 1+ 250·00
Supplied with: carrying case, test leads and two AA batteries.
Input AC Voltage, 100mV//A
Maximum input AC 170mV rms, 250mV Peak
A-D conversion Successive Approximation
Measurement method True RMS value
Memory capacity 3 ch. @ 20,000 readings, or 1 ch. @ 60,000 readings
Measurement Interval 1, 2, 5, 10, 15, 20, 30 sec., 1, 2, 5, 10, 15, 20, 30, 60 min.
Maximum Display 1049 counts
Over-range indication Display of
Insulation resistance Over 50MΩ @ 1000V
Size and Weight Model 5000: 111 x 60 x 36 mm, 255 g
Model 5001: 111 x 60 x 42 mm, 315 g
Power Model 5000: Alkaline battery LR6 x 4
Model 5001: Alkaline battery LR6 x 6
Maximum a.c. Current (A) 300 Maximum d.c. Voltage (V) 600 Resolution a.c. Current (mA) 10 Resolution d.c. Voltage (mV) 0.1 Basic Accuracy a.c. Current (%,mA) ±(3% rdg +3 digits)
(50 to 60 Hz) Basic Accuracy d.c. Voltage (V, mV) ± (0.5% rdg + 2
digits) Maximum d.c. Current (A) 300 A Resistance Range 400Ω to 40MΩ
Resolution d.c. Current (A, mA) 10 mA Resistance Resolution (Ohms) 10KΩ (40 MΩ
range) Basic Accuracy d.c. current (A, mA) ±(2% rdg +2 digits) Resistance Accuracy (%, Ohms) ±(2.5% rdg +5 digits)Maximum a.c. Voltage (V) 600 Maximum Jaw Capacity (mm) 22 Resolution a.c. Voltage (V) 1 Size (HxWxD) and Weight 192 x 66 x 27mm,
205g Basic Accuracy a.c. Voltage (%, Mv, V) ± (1.5% rdg +5
digits)
Cross-reference to manufacturer’s part no.
Kyoritsu part no Stock no.
5000 543-831
5001 543-841
8141 547-865
Description Stock no. Price per OM S$ S$ S$
Kew 5000 Leakage Logger 543-831 unit 1+ 1910·00
Kew 5001 Leakage Logger 543-841 unit 1+ 1910·00
Leakage Current Clamp 547-865 unit 1+ 440·00
Description Stock no. Price per OM S$ S$ S$
ICM30 697-3963 unit 1+ 240·00
ICM30R 697-3967 unit 1+ 270·00
2253
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
F15 True RMS
Fluke H3 Holster Accessory for the 321/322/333/334/335/336 and 337
Fluke 321 & 322
www.rssingapore.com
Fluke 381 Remote Display True-rms AC/DC Clamp Meter
Fluke 376 True-rms AC/DC Clamp Meterwith iFlex
Fluke iFlex Flexible Current Probes
Fluke 321
Dimensions: 231x90x64 mm
2500 A ac current measurement with select Fluke meters
Works with frequency, inrush, and min/max functions on
select Fluke meters
Large loop size and thin 7.5mm cross section allow
measurement of awkward sized conductors with
improved access in crowded spaces
CAT IV 600V, CAT III 1000 V safety rating
Compatible with Fluke 374, 375, 376 & 381 clamp meters
Wireless technology allows the display to be carried up to
10m away from the point of measurement for added
flexibility
Removable magnetic backlit display can be conveniently
mounted where it is easily seen
1000 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with iFlex flexible current
probe
1000 V ac (true rms) and dc voltage measurement
Frequency, resistance and continuity measurement
Display HOLD, Min, max, average and inrush recording
Large backlit display
1000 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with iFlex flexible current
probe
1000 V ac (true rms) and dc voltage measurement
500mV dc measurement range to interface with other
accessories
Frequency, capacitance, resistance and continuity
measurement
Display HOLD, Min, max, average and inrush recording
Contact RS for calibration requirements
Measurement Capability
True ac/dc rms current measurement (ac, dc, sinusoidal
or distorted)
Current up to 1000A a.c./1400A d.c.
Low pass filter for stable readings in noisy environments
CAT IV 600V, CAT III 1000 V safety rating
Low pass filter for stable readings in noisy environments
CAT IV 600V, CAT III 1000 V safety rating
600Vac/dc measurement
4kHz frequency measurement (voltage or current)
4MΩ resistance measurement (mains proof) and continuity
beeper
Auto-ranging with manual override for faster readings
Min./max measurement - ideal for momentary voltage or
current peaks (in rush current)
Display HOLD
Diode Test function
Complies with EN61010-2-032 CAT III 600V
Supplied with: 18in iFlex current probe, soft carry case, 2 x AA alkaline batteries and instructions
Fluke 322
Supplied with: 18in iFlex current probe, TL75 test leads, soft carry case, 5 x AAA alkaline batteries
and instructions
Note: Please contact RS for calibration requirements
Accessories
Supplied with: carry case, test lead set, 9V alkaline PP3 battery
Note: Please contact RS for calibration requirements
Description Stock no. Price per OM S$ S$ S$
H3 Holster 410-1242 unit 1+ 53·70
Note: Please contact RS for calibration requirements
Measurement Range Resolution Accuracy
AC Current* 2500 A 0.1 A 3% ± 5 digits
Frequency* 500 Hz 0.1 Hz 0.5% ± 5 digits
External magnetic field rejection 40 dB (with cable >10 cm from the coupling)
Inrush When used with compatible Fluke meter
* Accuracy stated includes probe and meter accuracy
New smaller size fits easily into tight places
Precise measurements with 1.8% basic accuracy
Resolution up to 0.1A and 0.1V AC
Measures AC current to 400 A
Measures AC voltage to 600 V
Resistance measurement to 400 Ω
Continuity for quick checking of shorts
Display hold function
Automatic low battery indicator
Auto power-off function
Fluke 322 only:
and instruction manual.
Measurement Range Resolution Accuracy
AC Current via Jaw 1000 A 0.1 A ±(2% + 5 d)
AC Current via iFlex 2500 A 0.1 A ±(3% + 5 d)
DC Current 1000 A 0.1 A ±(2% + 5 d)
AC Voltage 1000 V 0.1 V ±(1.5% + 5 d)
DC Voltage 1000 V 0.1 mV ±(1% + 5 d)
Resistance 60000 Ω 0.1 Ω ±(1% + 5 d)
Frequency 500 Hz 0.1 Hz ±(0.5% + 5 d)
Capacitance 1000 μF 1 μF ±(1% + 4 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)
Description Stock no. Price per OM S$ S$ S$
I2500-10 10 in. iFLEX probe 705-1945S unit 1+ 173·00
I2500-18 18 in. iFLEX probe 705-1954S unit 1+ 173·00
Measurement Range Resolution Accuracy
AC Current via Jaw 1000 A 0.1 A ± (2% + 5 d)
AC Current via iFlex 2500 A 0.1 A ± (3% + 5 d)
DC Current 1000 A 0.1 A ± (2% + 5 d)
AC Voltage 1000 V 0.1 V ± (1.5% + 5 d)
DC Voltage 1000 V 0.1 V ± (1% + 5 d)
Resistance 60000 Ω 0.1 Ω ± (1% + 5 d)
Frequency 500 Hz 0.1 Hz ± (0.5% + 5 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)
Stock no. Price per OM S$ S$ S$
705-1932S unit 1+ 664·00
DC voltage measurement capability
Additional 40A AC current range gives 0.01A resolution
Current ranges (ac/dc) 400A & 1000A Frequency resolution 0.01Hz, 0.1Hz, 1Hz Current resolution (ac/dc) 0.1A & 1A Requency accuracy ±(0.1% rdg + 15 digits) Maximum measurement 1000A ac, 1400A dc Resistance ranges 400Ω, 4kΩ, 40kΩ, 400kΩ,
4MΩ
Basic accuracy ac/dc current±(2.5% rdg + 2 digits) Resistance resolution 0.1Ω, 1Ω, 10Ω, 100Ω, 1KΩ
Voltage ranges (ac/dc) 400mV, 4V, 40V, 400V, 600V Accuracy resistance < 400Ω ±(1.5% rdg + 7 digits) Voltage resolution (ac/dc) 0.1mV, 1mV, 10mV, 100mV, 1V Accuracy resistance > 400Ω ±(1.5% rdg + 4 digits) Basic accuracy ac voltage ±(1.5% rdg + 2 digits) Continuity buzzer threshold 40Ω on 400Ω range Basic accuracy dc voltage ±(1% rdg + 2 digits) Maximum Jaw Capacity (mm) 42 (Dia); 50 x 5 (Bus bar) Frequency ranges 100Hz, 1kHz, 4kHz Size (HxWxD) and Weight 254 x 97 x 46mm, 600g
Stock no. Price per OM S$ S$ S$
705-1923S unit 1+ 1014·00
Contact RS for calibration requirements.
Stock no. Price per OM S$ S$ S$
207-4435 unit 1+ 510·00
Standards: IEC 1010-2-032, 600V CAT IIISupplied with: Carry case, test leads & instruction manual
Fluke 321 Fluke 322
Voltage DC – 0 - 600 V
Voltage DC resolution – 1 V
Voltage DC Accuracy – 1% ± 5 counts
Voltage AC 0 - 400 V 0 - 400 V
Voltage AC resolution 0.1 V 0.1 V
Voltage AC max 0 - 600 V 0 - 600 V
Voltage AC resolution 1 V 1 V
Voltage AC Accuracy 1.2% ± 5 counts (50 - 400 Hz)
Current AC 0 - 400 A 0 - 400 A
Current AC resolution 0.1 A 0.1 A
Current AC max – 0 - 40 A
Current AC resolution – 0.01 A
Current AC Accuracy 1.8% ± 5 counts (50 - 60 Hz)
3.0% ± 5 counts (60 - 400 Hz)
Resistance Range 0 - 400 Ω 0 - 400 Ω
Resistance resolution 0.1 Ω 0.1 Ω
Resistance Accuracy 1% ± 5 counts
Continuity Buzzer Operates at < 30 Ω on Resistance measurements
Operating Temperature -10°C to +50°C
Storage Temperature -30°C to +60°C
Power source 2 x AAA battery, typical life 100 hours (Zinc Carbon)
Size and Weight 190 x 63 x 35 mm, 230 g
Temperature de-rating of measurement accuracy:Add 0.1x specified accuracy for each °C above 28°C or below 18°C
Model Stock no. Price per OM S$ S$ S$
Fluke 321 543-318 unit 1+ 190·00
Fluke 322 543-314 unit 1+ 200·00
2254
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Kyoritsu 2033 AC/DC Current Mini Clamp Meter
Kyoritsu 2009A AC/DC 0 to 2009A True RMS
Kyoritsu 2003A AC/DC 0 to 2000A
Fluke 355 True-RMS, 2000A AC/DC
Fluke 353 True-RMS, 2000A AC/DC
ICM139R 1000A AC/DC,True-rms reading
ICM2000
4000 count backlit display
4000 count backlit digital display with analogue bargraph
True RMS reading on a.c. mode
NickelSteel alloy jaw mechanism
1000A a.c./d.c. current measurement
1000V a.c./d.c. voltage measurement
Resistance & continuity beeper <30Ω
Display hold & Min Max Function
10ms peak Hold on ACA & ACV
Frequency Counter
Auto Power Off (30 minutes)
51mm dia. conductor jaw capacity
Separate battery compartment
Complies with EN61010 CAT. IV 600V/ CAT. III 1000V Safety Standard for industrial
applications
4000 count backlit display
Tear drop jaws for ease of use in confined areas
Accurate True RMS reading of AC current and
voltage regardless of the whole waveform
Average function for fluctuating current and voltage
A 2000A a.c./d.c. clamp meter designed to meet BSEN61010 &
24mm diameter tear drop shaped jaws
Minimum resolution of 0.01A AC&DC
Data hold function
Auto zero function for one touch zero adjustment
Tear drop shaped jaws for use in tight spaces
Auto-Null function for one-touch zero adjustment
Maximum measurement function for ease of
reading peak currents over a period of time
Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032
Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.
measurements
BSEN61010-2-032 600V cat III.
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V
True-RMS AC + DC measurements
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 VStandards: IEC 61010-1 CAT III 300V, IEC 61010-2-032
Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032
Range/Resolution Basic Accuracy
a.c. voltage 400V/0.1V 750V/1V
±(1.0% rdg+5d) 50 to 500Hz
d.c. voltage 400V,/0.1V 1000V/1V
±(0.7% rdg+ 2d)
a.c. current 400A,/0.1A 1000A/1A
±(1.5% rdg+ 5d) 50Hz/60Hz ±(1.9% rdg+ 7d) 50Hz/60Hz
d.c. current 400A,/0.1A 1000A/1A
±(1.0% rdg+ 3d)±(1.9% rdg+ 7d)
Resistance 400Ω/0.1Ω ±(1.0% rdg+ 3d)
Frequency counter 20 to 400Hz/1Hz ±(0.1% + 2d) @ 5V rms max
Size (HxWxD) and Weight 275 x 90 x 51mm, 420g
Additional error due to remanence: 1% of current peak max.
AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source R6P(AA) (1.5V) x 2 DC V 400/1000V Approx. 100hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 530g approx.
Supplied with: C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads,
TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual
Supplied with: C43 soft case, 6 AA batteries and users manual
4000 count LCD display
DC current measurements to 2500A
AC current, true rms and Crest Factor to 2000A
AC/DC voltage to 600V
Max./min. hold
Resistance and continuity measurement
Diode Test
Frequency measurement
Low battery indication
Digital and bar graph display
AC A 40/300A (Autoranging) Power Source 1.5V button cell x 2 type LR-44 or SR-44 DC A 40/300A (Autoranging) Dimensions (mm) 147 (L) 59 (W) 25 (D) Conductor Size ∅24mm max. Weight 100g approx.
AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 40/400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source 6F22(9V) x 1 approx. DC V 40/400/1000V 15 hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 540g approx. Frequency 10 to 4000Hz
Stock no. Price per OM S$ S$ S$
420-0765 unit 1+ 270·00
Stock no. Price per OM S$ S$ S$
420-0743 unit 1+ 500·00
Stock no. Price per OM S$ S$ S$
697-3951 unit 1+ 405·00
Contact RS for calibration requirements
Contact RS for calibration requirements
Note: Colour may differ from that shown.
Stock no. Price per OM S$ S$ S$
420-0759 unit 1+ 570·00
Voltage Range AC/DC 0-4.000 V, 0-40.00 V, 0-400.0 V, 0-600 V ACrms, 0-1000 V DC
Basic Accuracy 1% ± 5 counts
Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A; 1400 AC rms
Basic Accuracy 1.5% ± 5 counts
Resistance range 0-400.0 Ω, 0-4.000 kΩ, 0-40.00 kΩ, 0-400.0 kΩ
1.5% ± 5 counts
Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz
Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts
Size (H x W x D) and weight 300 x 98 x 52mm: 814g
Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A, 1400 AC rms
Basic Accuracy 1.5% ± 5 counts 1.5% ± 5 counts
Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz
Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts
Size (H x W x D) and weight 300 x 98 x 52mm: 814g
Maximum a.c. current 2100A Maximum d.c. voltage (V) 0.4; 4 ; 40; 400; 600 Resolution a.c. current (A) 0.1 (400 A); 1 (1000 A); 1 (2100
A) Resolution d.c. voltage 0.1 mV (400 mV); 0.001 V (4 V);
0.01 V (40 V); 0.1 V (400 V); 1 V (600 V)
Basic accuracy a.c. current ± 3% ± 5 digits (40 to 1 kHz) Basic accuracy d.c. voltage ± 1.5% Rdg ± 3 digits Maximum d.c. current (A) 400; 2000; 2500 Resistance range (Ω) 400; 4 kΩ; 40 kΩ;
400 kΩ; 4 MΩ; 40 MΩ
Resolution d.c. current (A) 0.1 (400 A); 1 (2000 A); 1 (2500A)
Resistance resolution (Ω) 0.1 (400 Ω); 1 (4 kΩ); 10 (40 kΩ); 100 Ω (400 kΩ); 1 kΩ (4 MΩ); 10 kΩ (40 MΩ)
Basic accuracy d.c. current ± 2% Rdg ± 3 digits Resistance accuracy ± 1.5% Rdg ± 3 digits Maximum a.c. voltage (V) 0.4; 4; 40; 400; 600 Maximum jaw capacity
(mm) 55 (Dia); 65 x 24 (Bus bar)
Resolution a.c. voltage 0.1 mV (400 mV); 0.001 V (4 V); 0.01 V (40 V); 0.1 V (400 V); 1 V (600 V)
Size (HxWxD) and Weight 271 x 112 x 46mm, 647g
Basic accuracy a.c. voltage ± 2% Rdg ± 5 digits (40 to 1 kHz)Power supply 9V PP3 battery
Stock no. Price per OM S$ S$ S$
411-970S unit 1+ 1299·00
Stock no. Price per OM S$ S$ S$
411-974S unit 1+ 1083·00
Stock no. Price per OM S$ S$ S$
697-3702 unit 1+ 500·00
2255
www.nguyenxuong.com
Process Clamp Meters
HVAC Clampmeters
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
Fork Current Tester 2300R
Sanwa DCM400 Series Clamp Meter
Fluke 771 mA Process Clamp Meter
Fluke 902 HVAC Current Clamp
www.rssingapore.com
Kyoritsu 2037 Clampmeter
2046R AC/DC True RMS Clamp Meter
2300R features:
High accuracy auto-ranging True RMS AC/DC Clamp
Multimeter
CAT.IV Clamp Meters can measure voltages and
currents in both very low and high power circuits
6039 counts with Bar Graph display
Red LED, as "Non Contact Voltage" function, gives
Able to measure current frequency
4000 count display
Voltage frequency measurement range up to 10MHz
To IEC1010 CATIII 300V, CATII 600V
Measure mA signals for PLC and control system analog I/O
Teardrop shaped jaws for use in confined spaces
Measure 4 to 20 mA output signals from transmitters without breaking the loop
Hold function captures and displays changing measurements
Dual backlit display with both mA measurement and percent of 4 to 20 mA span
Measurement spotlight illuminates hard to see wires in dark enclosures
Detachable clamp head with extension cable for measurements in tight locations
Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
Non-contact voltage function
True RMS Reading
DCM 400
warning to the user of the presence of AC Voltages
MIN/MAX measurement function
Double-moulded case construction gives comfortable handling
Applications include power distribution, power utilities and maintenance
fields
600V ac/dc voltage measurement
600A ac current measurement
200μA dc current measurement ideal for flame sensor testing
Resistance and capacitance measurement
Auto Power-Off
Data Hold (AC A/DC A Only)
4000-count LCD display
Measures both AC and DC current and voltage
True RMS reading permits precise measurements of non-sinusoidal AC
currents and voltages
AC measurements extend down to 10 Hz
Normal, Average, Peak or Frequency reading selection
Supplied with: 2 AA batteries, soft carry case and user manual.
Standards: IEC 61010-1 CAT.IV 600V; IEC61010-031; IEC61010-2-032; IEC61326
Frequency measurement by clamp or test leads
DCM 400 AD
Standards: IEC61010-1 CAT.III 600V Pollution Degree 2, IEC61010-2-031
Function Range Resolution Accuracy
Measure 4-20mA -20.99 to +20.99 mA 0.01mA 0.2% or reading + 5counts
Measure 10-50mA -21 to -99.9 mA;+21 to +99.9 mA
0.1mA 1% or reading +5 counts
Dimensions & weight 59 x 38 x 212 mm; 260g
400°C contact temperature with standard K-type thermocouple
Backlit display shows actual and Min/Max measurements with display hold
function
Complies with IEC 61010-1, IEC 61010-2-032 CAT III 600V
Standards: IEC 61010 - 1, CAT III 300V PollutionDegree 2
Supplied with: Carry case and test leads.
One push calibration for DC(A)
Relative Measurement
Supplied with: Carry case, test leads, battery and iinstruction manual
Stock no. Price per OM S$ S$ S$
287-642S unit 1+ 886·00
AC Current 0-600.0A±2.0 5dgt (50/60Hz)±3.5 5dgt (40∼500Hz)
Continuity Check Buzzer Sounds at 100Ω
DC Current 0-600.0A±1.5 ±5dgt
Conductor Size ∅33mm max.
AC Voltage 6/60/600VAuto Ranging±1.5 ±4dgt (50/60Hz)±3.5 ±5dgt (40∼400Hz)
Withstand Voltage 6880V AC for 5 seconds
DC Voltage 600m/6/60/600VAuto Ranging±1.0 ±3dgt
Dimensions 243(L) × 77(W) × 36(D)mm
Resistance 600/6k/60k/600k/6M/60MΩ (Auto Ranging)±1 ±5dgt (600-6M) / ±5 ±8dgt (60M)
Weight 300g
Frequency/Duty 10/100/1k/10kHz (Auto Ranging) / 0.1∼99.9%
Measurement Ranges AC Current equals +/- 2% rdg +/- 5 digits(50 - 60 Hz)
DC Current 0 to +/- 100 A Power Source R03 (AAA) x 2 AC Current 0 to 100A Dimensions (mm) 161.3 (L) 40.2 (W) 30.3 (D) Accuracy Weight 110g (with batteries) DC Current equals +/- 2% rdg +/-5 digits
Supplied with: 2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM
Temperature probe, users manual, soft carrying case.
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
255-023 unit 1+ 425·00
Stock no. Price per OM S$ S$ S$
466-6042 unit 1+ 205·00
Function Measurement ranges Accuracy
DC Voltage 40V, 400V, 600V ± (1% reading + 5 digits)
AC Voltage 40V, 400V, 600V ± (1.5% reading + 5 digits) 50-60Hz, CF<3
± (3.5% reading + 5 digits) 40Hz-1kHz
DC Current 400A, 1000A ± (1% reading + 5 digits)
AC Current 400A, 1000A ± (1.5% reading + 5 digits) 50-60Hz, CF<3
± (3.5% reading + 5 digits) 40Hz-1kHz
Frequency 3000 Hz ± (1.5% reading + 5 digits)
Resistance 400Ω, 4000Ω ± (1% reading + 5 digits)
Continuity buzzer Sounds at <20Ω on 400Ω range
Conductor size, AC/DC current Maximum 33mm Ø
Withstand voltage 5550Vac for 1 minute
Power Source 6F22 or equivalent (PP3 9V) battery
Size (LxWxD) and Weight 208 x 91 x 40 mm, approx. 450 g
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
543-289 unit 1+ 475·00
Range Accuracy Resolution
Volts DC 0 to 600V ±(1% + 5d) 0.1V
Volts AC 0 to 600V ±(1% + 5d) 0.1V
Current AC 0 to 600A ±(2% + 5d) 0.1A
Current DC 0 to 200μA ±(1% + 5d) 0.1μA
Resistance 0 to 9999Ω ±(1.5% + 5d) 0.1Ω
Temperature -10 → +400 °C ±(1% + 0.8°C) 0.1°C
Capacitance 1μF to 1000μF ±(1.9% + 2d) 0.1μF
Continuity ≤30 Ω
Maximum jaw capacity 30mm
Dimensions & weight 280 x 80 x 40 mm, 310g
Note: Image shows DCM400AD only, DCM400 is similar
Stock no. Price per OM S$ S$ S$
131-303S unit 1+ 450·00
DCM 400 DCM 400 AD
AC (A) 40/400 A 40/400 A
DC (A) – 40/400 A
AC (V) 400/600 A 400/600 V
DC (V) 400/600 V 400/600 V
Frequency (A) 20-4k/10kHz –
Frequency (V) 4k/40k/400k/4M/10MHz –
Resistance (Ω) 400Ω 400Ω
Clamp Diameter 25 25
Manu. Part No. Stock no. Price per OM S$ S$ S$
DCM400 353-3957 unit 1+ 175·50
DCM400AD 353-3963 unit 1+ 300·00
2256
www.nguyenxuong.com
Power Clamp Meters
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
ISO-TECH 6600 Power Clamp
ISO-TECH IPM2009R
ISO-TECH IPM3000N HVACPower Clamp Meter
ISO-TECH IPM138 HVAC AC/DC Power Clamp Meter
Amprobe ACD-14 TRMS FX
3¾ digit 4000 count LCD with fast analogue bar graph
The IPM3000N is a 1000Aac power meter with features ideally suited to HVAC and
electrical maintenance applications.
The ACD 14 FX is the professionals’ choice for both HVAC &
Electrical applications due to its complete set of measuring
A power clampmeter designed to meet the BSEN61010 &
The IPM138 is a 600A ac/dc power meter with features ideally suited to HVAC and
electrical maintenance applications.
True rms reading
AC+DC 1200KW power measurement
DC/AC 2000A current measurement with analogue output
Large 55mm jaw capacity (bus bars to 64mm x 25mm)
600Vac/dc voltage measurement
Type K thermocouple input. Type K adaptor (available separately) accepts
thermocouple sensors with miniature connectors
Continuity buzzer up to 40Ω
Auto-ranging A, V,°C & KW
Relative measurement
Display min/max. hold
Powered by 1x alkaline PP3 battery (supplied)
100MΩ resistance range
Safety to EN 61010-1 CAT III 600V
BS61010-2-032 600V cat III
features. Its dual display allows voltage and current to be viewed simultaneously, and
the True RMS capability gives accurate and reliable measurements.
10,000 count dual display LCD
True rms current & voltage measurement
True and apparent power and phase angle measurement (kW, kVA, Ø)
Dual display options (kW+PF, kVA+ Ø,V+A, A+Hz, V+Hz)
1000Aac current range to check motor & compressor current consumption
40mm clamp diameter
Min/Max with elapsed time to capture motor inrush current readings
Data hold facility
1nF to 3500μF capacitance range suits run/start capacitor checks
1kHz frequency measurement range
Diode and continuity test
μA range to measure flame sensor current
6000 count large backlit LCD display
True RMS current & voltage measurement AC + DC coupled
1000V ac/dc voltage measurement
600A ac/dc current measurement
600kW active power measurement and PF display
Total Harmonic Distortion measurement
AC current inrush measurement ideal for motor & compressor checks
MIN/MAX, Display and PEAK hold
20kΩ resistance measurement.
-50 °C to 1000 °C type K thermocouple temperature measurement input & sensor
4kHz frequency counter
Continuity & diode testAC/DC power factor measurement
AC/DC voltage measurement
AC/DC current measurement
3 phase AC/DC balanced & unbalanced
Apparent power & reactive power
Phase angle
Frequency measurement
10,000 count 4-digit dual LCD display
Powered by 9V alkaline PP3 battery (supplied)
Dual 33⁄4 digit 4000 count displays
True RMS reading, Auto-ranging
Current and Voltage can be read simultaneously
AC and DC Voltage to 600V
AC Current to 400A
Resistance to 40MΩ with Continuity Buzzer
Micro-amp measurements for testing “Flame Sensors”
Temperature reading via Type-K thermocouple probe
Capacitance to 3000 μF
Frequency measurement
Diode test
Hold and Maximum reading functions
Auto power-off and low battery indication
Accommodates conductors up to 1.02" (26mm) in diameter
Rubber over-moulded case
100MΩ resistance range
Size (HxWxD) and weight: 228x76x39mm, 465g
Meets with EN61010-1 IEC1010-2-032 600V Cat III
900°C range Type K thermocouple input socket.
Analyse time-stamped temperature and power data
Supplied with: test leads, 9V PP3 battery
35mm conductor jaw size
Complies with IEC 61010-1 CAT III 600V, CAT II 1000V
Supplied with: case, battery & instructions
Supplied with: Test leads, 2 x croc clips, case, 9V PP3 battery,7 instructions
Supplied with: Test leads, carry case, type K thermocouple probe & battery
Safety EN 61010-1 Accuracy dc current ±(1.5% + 3 digits) Power measurements 40; 400; 1200 KW Maximum ac voltage (V) 600 Temperature measurement(°C)
-50 to 400; 400 to 1000 Resolution ac voltage (V) 0.001 (4 V); 0.01 (40 V); 0.1(400 V); 1 (600 V)
Maximum ac current (A) 2100 Accuracy ac voltage ±(1.5% + 3 digits) Resolution ac current (A) 0.1 (400 A); 1 (2100 A) Maximum dc voltage (V) 600 Accuracy ac current ±(2.5% + 5 digits) Accuracy dc voltage ±(1.5% + 3 digits) Maximum dc current (A) 2500 Maximum jaw capacity (mm) 55; 64 x 25 Resolution dc current (A) 0.1 (400 A); 1 (2500 A) Size (HxWxD) and Weight 271 x 112 x 26mm, 647g
Supplied with: PP3 9V battery, carry case, test leads, type K thermocouple adaptor and type K bead
sensor, users manual, vinyl belt pouch.
Measurement Range Accuracy
DC Voltage 1000V ±(0.7% +5d)
AC Voltage (45Hz ∼ 500Hz) 1000V ±(1.0% +5d)
DC Current 600A ±(1.5% +5d)
AC Current 600A ±(1.5% +5d) 45Hz ∼ 65Hz ±(2.5% +5d) 6Hz ∼ 500Hz
Power measurement (kW) 600kW Sum of voltage & current errors
Power Factor PF -1 to +1 ± 3°
THD measurement (Fundamental 45 – 65Hz)
0 ∼100% ±(3% +10d)
Inrush Current (Integration time ∼100ms)
10.0 ∼ 59.9Aac 60.0 ∼ 600A
±(2.5% +2A) ±(2.5% +5d)
Temperature measurement -50 to +1000°C ±(1% +3°C)
Dimensions & weight 235mm x 78mm x 41mm 400g
Safety BSEN 61010; BS 61010-2-032 Accuracy dc current (A,mA)
± 2.5% ± 5 digits (50 / 60 Hz); ± 3%± 5 digits (40 - 400 Hz)
Memory (Test results) Yes Maximum ac voltage (V) 600V (ac + dc, Trms) Phase angle accuracy(%)
± 2 Resolution ac voltage (V) 0.1 (0 - 200 V); 0.1 (200 - 500 V); 1(500 - 600 V)
Maximum ac current (A) 2000A (ac + dc, Trms) Accuracy ac voltage ± 1.5% ± 5 digits (50 / 60 Hz); ±2.0% ± 5 digits (40 - 400 Hz)
Resolution ac current (A) 0.1 (0 - 200 A); 0.1 (200 - 500 A); 1(500 - 2000 A)
Maximum dc voltage (V) 600V (ac + dc, Trms)
Accuracy ac current ± 2.5% ± 5 digits (50 / 60 Hz); ± 3%± 5 digits (40 - 400 Hz)
Accuracy dc voltage ± 1.5% ± 5 digits (50 / 60 Hz); ±2.0% ± 5 digits (40 - 400 Hz)
Maximum dc current (A,mA)
2000 A (ac + dc, Trms) Maximum jaw capacity(mm)
55 dia. or 65 x 24 bus bar
Resolution dc current (A,mA)
0.1 A (0 - 200 A); 0.1 A (200 - 500A); 1 A (500 - 2000 A)
Size (HxWxD) andWeight
271 x 112 x 46mm, 647g
Stock no. Price per OM S$ S$ S$
697-3733 unit 1+ 580·00
Standards: CE, CAT III 600V
Function Measuring Ranges Basic accuracy Range resolution
Power measurement 60 → 600 kW/kVA ±5% 10 → 100 W/VA
Phase angle -60° → +60° ± 6° 0.1°
DC Voltage 999.9 mV → 600 V ±1.0% 100 μV → 0.1 V
AC Voltage 999.9 mV → 600 V ±2.0% 100 μV → 0.1 V
μA (AC+DC) Current 99.99 μA → 999.9 μA ±1.0% 10 nA → 100 nA
AC Current 99.99 mA → 999.9 A ±2.0% 10 mA → 1 A
Resistance 999.9 Ω → 99.9 MΩ ±1.0% 100 mΩ → 10 kΩ
Capacitance 10 μF → 7000 μF ±1.5% 1 nF→ 1 μF
Frequency 40 Hz → 1kHz ±0.5% 0.01Hz
AC V 4.000V/40.00V/400.0V/600 V Accuracy: ±(1.5% Rdg + 5 digits)
DC V 0-400.0 mV/4.000V/40.00V/400.0V/600V Accuracy: ±(0.5% Rdg + 3 digits )
AC A 0-40.00A/400.0A Accuracy: ±(1.9% Rdg + 8 digits)
AC/DC microamps 400μA/2000μA Accuracy: DC: ±(1.5% Rdg + 4 digits), AC: ±(2.0% Rdg + 5 digits)
Resistance 0-400.0 Ω/4.000 kΩ/40.00 kΩ/400.0 kΩ Accuracy: ±(0.6% Rdg + 4 digits)
Capacitance 500.0nF/5.000μF/50.00μF/500.0μF/3000μF Accuracy:±(3.5% Rdg + 6 digits)
Frequency 10Hz to 100kHz Accuracy: ±(0.5% Rdg + 4 digits)
Temperature -4°F to 572°F (-20°C to 300°C) Accuracy: ±(2.0% Rdg + 6°F)
Conductor Size 26mm diameter max.
Size (LxWxH) and Weight 190 x 63 x 32mm, 204g
Stock no. Price per OM S$ S$ S$
697-4067 unit 1+ 260·00
Stock no. Price per OM S$ S$ S$
697-3780 unit 1+ 750·00
Accessories
Stock no. Price per OM S$ S$ S$
697-3746 unit 1+ 260·00
Type Clamp Multimeter Maximum Voltage 600 VCurrent Type AC Max. Conductor Size 26 mmMaximum Current 400 A
Description Stock no. Price per OM S$ S$ S$
Thermocouple AdaptorKDMM I/P
222-0234 unit 1+ 15·50
Stock no. Price per OM S$ S$ S$
543-885 unit 1+ 167·50
2257
www.nguyenxuong.com
Power Quality Analysers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Fluke 43B Power Quality Analyser
Fluke 434/PWR Power Analyser Kit
Fluke 434 & 435 3 Phase Power QualityAnalysers (3U+I)
Fluke 1735 Power Logger
Voltage, current and power harmonics to the 51st, phase angle and THD
Sag and swell measurement down to one cycle, recorded over time
Voltage, current and frequency measurement, and waveform display
Power measurements - watts, power factor, displacement power factor, VA
and Var
Complete three-phase
troubleshooting tool for finding
energy waste in commercial and
factory buildings and equipment.
Number of inputs: 4 voltage and
current (3 phases + neutral).
Maximum input voltage: 1000 Vrms
(6 kV peak).
Maximum sampling speed: 200 kS/s
on each channel simultaneously.
Vrms (AC+DC): 1 … 1000 V.
20 measurement memory to save/recall screens and data with cursor readings
Captures up to 40 voltage transients
Ohms, continuity and capacitance measurement
Temperature scaling for temperature accessories
Calculates 3-phase power on balanced loads
The Fluke 1735 Power Logger is the ideal
tool for electricians and maintenance
technicians for conducting energy studies
and basic power quality logging. The 1735
Contact RS for calibration requirements
Note: VPS40 Voltage Probe and 61 IR Thermometer are not included as this
product not is sourced from Europe
Volt/Amps/Hertz.
Dips and swells.
Power and energy: Watt, VA, VAR, kWh, kVAh, kVARh, Power Factor / Cos / DPF.
Unbalance, Harmonics. & inter-harmonics
Autotrend recording: Up to 450 days.
Memory - Screens and Data: 50, shared memory divided between logging, screens and data sets
Fluke power quality analysers help locate,
predict, prevent and troubleshoot problems in
power distribution systems and include many
features to capture details to pinpoint problems
quickly and safely. Troubleshooting is fast with
on-screen display of trends and captured events,
logs most electrical power parameters, harmonics and
captures voltage events. View graphs and generate reports
with the included Fluke Power Log software.
Supplied with: Rugged soft carry case, i430-Flexipack 4 current clamps, 5 Test leads, BC430 Battery
charger eliminator, Power Log Software, OC4USB Optical cable for USB, Colour localization set, user
manual pn CD-ROM
3 Phase power meter and data logger in one instrument
ideal for troubleshooting, load profiling and supply
monitoring
even while background recording continues.
Confirm instrument setup easily with colour display of waveforms and trends
Record power and associated parameters for up to 45 days with built in 4MB flash memory, 3.5MB
for measuring data
Measures all three phases and neutral with 4 flexible 3000A ac current probes (supplied)
Numerical display of RMS values of current and voltage, plus frequency and related parameters
High resolution colour transmissive ¼VGA display (320 x 240) for waveform, harmonics, chart and
multi parameter display
Prove the benefit of efficiency improvements with power & energy consumption tests in single or
three phase systems, star or delta configuration
Measure harmonic distortion caused by electronic loads for voltage and current up to the 50th
Identify system power characteristics with internal trend recording with real time clock for RMS
values of voltage and current, power & energy
Improve reliability by capturing voltage dips and swells from load switching
Monitor maximum power demand over user-defined averaging periods
Automatic recording of min., max., average values (1⁄2 cycle values)
On screen analysis or data download via RS-232 for reporting and archiving of results
NiMH rechargeable battery giving typically 12 hours operation or mains powered for continuous
use
No. Phases 4Maximum Voltage 1000 Vrms
Complete three-phase troubleshooting tool: measures voltage,
current, frequency, power, unbalance and flicker, harmonics, inter
harmonics, power consumption (Energy) and inrush
AutoTrend: Every displayed reading is automatically and
continuously recorded without having to set up threshold levels or
interval times
Displays trends in voltage, current, frequency, power, harmonics or
Description Stock no. Price per OM S$ S$ S$
Fluke 434/PWR 705-1272Sa unit 1+ 9321·00
Standards: IEC 61010-1, 600V CATIII, Pollution degree 2
Supplied with i400s ac current clamp (4 supplied) range 0.5A to 400A; , maximum conductor
diameter 32mm. Safety rating CAT IV, 600V
flicker on all three phases plus neutral
Analyse the trends using the cursors and zoom function while background recording continues
System-Monitor: gives immediate insight into power system’s quality. Checks conformity to limits
specified in EN50160 or to user defined limits. The overview is shown on a single screen, with
colour-coded bars clearly indicating which parameters fall outside the limits
Inrush mode for troubleshooting nuisance circuit breaker tripping
Four channels: simultaneously measures voltage and current on all three phases and neutral
Meets EN61010-1 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the
service entrance.
Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH
battery pack
Complies with IEC 61000-4-30 measurement standards.
Stored measurements can be transferred to a PC to view graphs and generate reports with
FlukeView software with OC4USB interface adaptor / cable (supplied)
Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically
8MByte memory, shared memory divided between logging, screens and datasets
Fluke 435 Advanced Features
Supplied with: Soft carrying case, 4 flexible current probes (15A/150A/3000 A), Power Log software,
Voltage leads and clips, Colour localisation set, RS-232 PC interface cable, (9 way) mains adaptor.
Fully Class A Compliant - conduct tests according to the stringent international IEC 61000-4-30 Class
A standard
Configure for any test condition with memory for over 400 parameters at user defined intervals
16MByte memory, shared memory divided between logging, screens and datasets
Measure interference from specific frequency signals with mains signalling function
i430 flexible current clamp (4 supplied as standard) range 30A to 3000A ac; , maximum conductor
diameter 160mm. Safety rating CAT IV, 600V
C435, Hard carrying case with handle and wheels
PowerLog software
Volts rms V-rms (STAR) measurement ranges:57V/ 66V/ 110V/ 120V/ 127V /220V/ 23 V/ 240V/ 260V/ 277V/ 347V/ 380V/ 400V/417V/ 480V acV-rms (DELTA) measurement ranges:100V/ 115V/ 190V/ 208V/ 220V/ 380V/ 400V/ 415V/ 450V/ 480V/ 600V/ 660V/ 690V/720V/ 830V ac
Amps rms Flexi set measurement range: 15A/ 150A/ 3000A rms (at sine)Current clamp measurement range: 1A/ 10A
Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Harmonics and THD To 50th harmonic (< 50 % of nom)
Power measurementMeasuring range(P - Active, S - Apparent, Q- Reactive, D - Distorting)
see V-rms and A-rms measurement ranges
Energy Measurement (kWh,KVAh, kVARh)
1 W to 10 W resolution
PF (Power factor) 0.000 to 1.000
Events Detection of voltage dips, voltage swells and voltage interruptions with a 10msresolution and measuring error of the half period sine wave of rms
Memory 4 MB Flash memory, 3.5 MB for measuring data
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Display VGA Graphic Color transmissive displays 320 x 240 pixels with additionalbackground lighting and adjustable contrast, text and graphics in color
Interface RS-232 SUB-D socket; 115.2 k Baud
Power supply NiMH battery-pack, with ac adapter (15V to 20V / 0.8A)
Operating temperature 0 °C → +40 °C
Size (HxWxD) 240 mm x 180 mm x 110 mm
Weight 1.7 kg, including battery
Current Clamp Options
Stock no. Price per OM S$ S$ S$
636-2809 unit 1+ 4934·00
i430Flex 3000A ac flexible current clamps (set of 4 supplied as standard with 435) range 30A to
3000A, maximum conductor diameter 160mm. Safety rating EN610101 CAT IV, 600V
i5sPQ3: 5Aac current clamps (3 in a set) range 10mA to 5A; maximum conductor diameter 15mm,
Safety rating EN610101 CAT III 600V
i1000s, ac current clamp (sold individually) range 0.1A to 1000 A rms, maximum conductor
diameter 54mm. Safety rating EN610101 CAT III 600V
Contact RS for calibration requirements
Note: 3 year warranty on Analyser units 434 & 435 only.
Supplied with: Hard carrying case (Fluke 434 with C434, Fluke 435 with C435 with handle and
wheels), 4 current probes, 5 test leads and crocodile clips, NiMH battery charger, BP190 NiMH
rechargeable battery (installed), FlukeView analysis (Fluke 434 and 435) & PowerLog software (Fluke
435 only), OC4USB optical USB cable, colour localisation set, quick start printed manual, user manual
CD.
Range Accuracy
Voltage Vrms (AC+DC) 1 to 1000V ±0.1% of nominal (FL435) ±0.5% of nominal (FL434)
Current Arms (AC+DC) 0 to 20000A ±0.5% ± 5 counts Frequency 42.50 57.50 Hz ±0.01% Harmonics DC, 1 – 50 (Off, 1 – 49) Power Watt,VA,VAR 1.0 – 20MVA ±1.0% ± 10 counts Energy * kWh,kVAh,kVARh 0.00 – 200.0 GVAh ±1.5% ± 10 counts Power Factor 0 - 1 ±0.03 Flicker Pst(1min),Pst,Plt,PF5 0.00 – 20.00 ±5% Unbalance Volts 0.0 – 5.0% ±0.15% Unbalance Current 0.0 – 20% ±1% Transient capture ±6000V ±2.5% of Vrms Min transient capture time 5μs Inrush Arms (AC+DC) 0.00 – 20.00 kA ±1% of measurement ± 5 counts Memory - Capacity 8MByte (FL434)
16MByte (FL435) Shared memory divided between logging, screens and datasets
Memory - Screens/Data 50/10 Standards Measurement method: IEC61000-4-30 Class A;EN50160;IEC61000-4; IEC61000-4-7 Battery life 7hours; 4 hour typical charging time Size (HxWxD) and Weight 256 x 169 x 64mm, 2kg
Description Stock no. Price per OM S$ S$ S$
Fluke 435 613-1576 unit 1+ 13940·00
Fluke 434 493-5506a unit 1+ 10363·00
Accessories
Description Stock no. Price per OM S$
I5sPQ3 Clamp set of 3 530-0995a 1 set 1+ 2078·00
i1000s Clamp 408-8751a unit 1+ 937·00
2258
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
ISO-TECH IPM3005 3000Aac,Flexible Probe PowerQuality Tester
Fluke 345 Power Quality Clamp Meter
CA8220 Power Analyser
Balanced 3 phase and single phase 3000A power quality tester with
flexible 3000A probe and data logging functions for the
measurement and diagnosis of power problems in electrical
installations and power circuits. An optically isolated USB lead and
analysis software enables readings to be displayed and/or
downloaded for analysis on a PC or Laptop.
The Fluke 345 measures a wide range of electrical parameters for troubleshooting
The CA8220 is optimised for maintenance and
troubleshooting of electrical equipment, electrical systems
and in single phase and balance three phase systems.,The
CA8220 includes measurements for testing and monitoring
rotating machines in operation. including temperature,
current , duration of in-rush current, resistance of windings
and rotation speed.
power disturbances in single- and three phase electrical loads. With a bright colour
display to see waveforms and trends, a low-pass filter to remove high frequency noise,
and a high EMC immunity design, the Fluke 345 is ideal for measurements on
switching loads such as variable speed drives, electronic lighting and UPS systems.
True RMS measurement of Vac and Iac
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Energy calculation (WH and kWH)
Measures balanced 3Ø power and sequence
Clamp-on measurement of ac current up to 1400A rms and dc current up to 2000A
without breaking the circuit
Low pass filter ensures the clamp meter is accurate in noisy environments even with
distorted waveforms present on electronic loads
Identify intermittent faults by logging any power quality parameter for minutes, or
over a month, including harmonics
Direct measurement of dc ripple (%) for battery and dc systems
Analyse and log harmonics digitally or graphically
Inrush current measurement to capture and analyse nuisance tripping, from 3 to 300
seconds
Large backlit 173-segment LCD display.
Power measurement up to 250kW (dependant on clamp selection)
600V rms and up to 6,500A (with clamps)
Harmonics (IEC 1000-4-7) display up to 50th order
MIN, MAX, AVERAGE, PEAK and Crest Factor display
W, VA, VAR power, DF, THD, CosΦ
Inrush current measurements – Max instantaneous value; Max RMS half-
cycle current value and duration of motor start.
RPM rotation speed
Resistance measurement
Simultaneous recording of all parameters, alarms and motor start up
currents.
RS232 direct output to PC
2 wire PT100 temperature probe input
Select AC current probes separately :-
Ampflex A193: 10 to 6500Aac (10Hz to 20kHz) 450mm long flexible probe
(rs 236-565)
MN93A: 0.2 to 120Aac (40Hz to 10kHz): Jaw size 20mm dia. (rs 236-559)
IP54 Rated
Large backlit colour display of waveforms (scope function) and trends
Balanced 3-phase power measurement capability
Power Log software supplied to view graphs and generate reports on a PC
USB interface
Harmonic analysis: Analyse, display and log harmonics up to the 30th harmonic (40th harmonic for
15Hz to 22Hz)
Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
EN61010 safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance
Supplied with: Supplied with 6 off AA alkaline batteries, test leads, 4mm test
Fluke 43B Basic Fluke 43B
Power - 5 W Safety EN/IEC 61010-2-032; ANSI/ISA S82; CSA-C22.2 No.1010.1-92; UL 1244 Power Measurements 250W to 1.56GW Memory (Test results) Yes Phase Measurement Yes Phase Angle Accuracy ±3° to ±15°Power Factor 0 to 1.0 Capacitance Measurement Yes Temperature Measurement -100 to +400 C Maximum ac Current 1250kA (rms, ac + dc) Accuracy ac Current ± (1% +10 Counts) (rms, ac + dc) Maximum dc Current 1250kA (rms, ac + dc) Accuracy dc Current ± (1% +10 Counts) (rms, ac + dc) Maximum ac Voltage 1250V (rms, ac + dc) Accuracy ac Voltage (V, mV) ± (1% +10 Counts) (rms, ac + dc) Maximum dc Voltage 1250V (rms, ac + dc) Accuracy dc Voltage (mV, V, Percent) ± (1% +10 Counts) (rms, ac + dc) Continuity Check Yes Diode Test Yes Size (HxWxD) and Weight 232 x 115 x 50mm, 1.1kg
probes, crocodile clips, RS232/USB optical cable and instructions
Features & facilities
Standard available in all models 43B Basic 43B
Fliuke 43B Power Quality Analyzer YES YES
BP120MH Ni-MH Battery pack (Installed) YES YES
PM 8907 Battery Charger/Line Voltage Adaptor YES YES
TL24 Test Leads YES YES
AC20 Industrial test Clips YES YES
TP4 Slim Reach Test Probes (4mm) YES YES
BB120 Banana-to-BNC Adaptor plug YES YES
Model Difference
i400s AC Current Clamp (400 A) YES YES
SW43W FlukeView Software for Windows + Power Quality Video YES
OCBUSB Interface/Adaptor Cable YES
C120Hard Case YES
TP1 Slim Reach Test Probe Set (flat blade) YES
AC85 Large Jaw Alligator Clips YES
Users Manual / Application Guide (CD-ROM) YES YES
Getting Started Booklet YES YES
VPS40 Voltage Probe YES
Fluke 61 IR Thermometer YES
Supplied with: Test Leads, Power Log software on CD-ROM, USB lead, batteries(fitted), mains
adaptor, carry case & instructions.
Voltage range 6 VRMS to 600 VRMS AC+DC ±(0.5%+2pts) AC current range 5mA to 6500 A ±(0.5%+1pts) DC current range 1 A to 1700 A ±(1%+1pts) Fundamental frequency 40 Hz to 70 Hz Harmonics (IEC 1000-4-7) Up to 50th order Engine rotation speed 6 RPM to 120 kRPM ±(0.5%) Temperature (Pt100) 200°C to 850°C ±(1%+10pts) Resistance (coiling) 0.0Ω to 2000 Ω ±(0.5%+1 Ω) Phase rotation Yes, with display of phase order in three-phase IEC 61010-1 600 V, Cat. III
Current
DC, DC rms, AC rms All measurements dc and 15Hz to 1kHz. Amps rms is a true rms measurement (ac + dc)
Maximum overload 10,000 A or RMS x frequency < 400,000 Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency range
F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A Measuring range 0 – 2000 A dc or 1400 ac rms Accuracy DC, rms I > 10 A: ± 1.5 % rdg ± 5 digits
I < 10 A: ± 0.2 A Voltage measurement
DC, DC rms, AC rms All measurements dc and 15 Hz to 1 kHz. Volts rms is a true-rms measurement (AC + DC)
Maximum overload 1,000 V rms. Measuring range 0 – 825 V dc or ac rms Accuracy DC, rms V > 1 V: ± 1 % rdg ± 5 digits
V < 1 V: ± 0.02 V Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65
Hz; Vacrms > 1V Power (single and three phase)
Watts measurement 0 – 1650 kW dc or 1200 kW DC, DC rms, AC rms Accuracy 2.5 % rdg ± 5 digits
W1Ø < 2 kW ± 0.08 kWW3Ø < 4 kW ± 0.25 kW
VA measurement 0 -1650 kVA dc or 1200 kVA ac DC, DC rms, AC rms Accuracy VA > 2 kVA: 2.5 % rdg ± 5 digits
VA < 2 kVA: ± 0.08 kVA VAR measurement (0.3 < PF< 0.99)
0 – 1250 kVAR
Accuracy VAR > 4 kVAR: ± 2.5 % rdg ± 5 digitsVAR < 4 kVAR: ± 0.25 kVAR
Power factor &Displacement power factor
0.3 capacitive to 1.0 to 0.3 inductive (72.5° capacitive to 0° to 72.5° inductive)
Kilowatt Hour (kWHr) 40,000 kWHr Accuracy kWHr > 2 kWHr: ± 3 % ± 5 digits
kWHr < 2 kWHr: ± 0.08 kWHr Frequency Measurement
Accuracy 15 to 22 Hz ± 0.5 % rdg40 Hz to 70 Hz ± 0.5 % rdg15 Hz to 1000 Hz ± 1% rdg
Scope function
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Current measurement: Ranges 10A/ 20A/ 40A/ 100A/ 200A/ 400A/ 1000A/ 2000A Accuracy ± 3 % rdg ± 1 pixel Voltage measurement: Ranges 4V/ 10V/ 20V/ 40V/ 100V/ 200V/ 400V/ 1000V Accuracy ± 2 % rdg ± 1 pixel Inrush current function All measurements dc and 15 Hz to 1 kHz Ranges 40, 400 and 2000 A Memory Up to 50 screen shots and over 150,000 individual measurement values Safety IEC 61010-1 600 V CAT IV, 1000V CAT III Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight Jaw opening 60 mm, max conductor 58 mm diameter Battery type 6 off 1.5 V Alkaline AA MN 1500 or IEC LR6 Battery Eliminator BE345 Input 110/230 V 50/60 Hz
Output 15 V dc, 300 mA
Description Stock no. Price per OM S$ S$ S$
Fluke 43B 413-0004 unit 1+ 6072·00
Stock no. Price per OM S$ S$ S$
252-214S unit 1+ 3973·00
Stock no. Price per OM S$ S$ S$
237-394 unit 1+ 930·00
2259
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Accessories for Fluke 430 Series
ISO-TECH IPM6300 3000A acGraphical Power QualityAnalyser
ISO-TECH IPM6200 1500A acPower Quality AnalyserA single phase and balanced 3 phase 1500A ac graphical power quality analyser
with data logging functions for analysis and diagnosis of power quality & power
disturbance problems in electrical installations and power circuits. Optically isolated
USB connection lead & analysis software is supplied enabling readings to be
displayed and recorded data to be downloaded controlled and analysed on a PC or
laptop computer.
Balanced 3 phase and single phase 3000A graphical power
quality analyser with data logging functions for the analysis
and diagnosis of power quality and disturbance problems in
electrical installations and power circuits. An optically
isolated USB lead and analysis software enables readings to
be displayed and/or downloaded for analysis on a PC or
Laptop.
OC4USB: Optical USB interface
cable
BC430: Battery charger/mains
Power quality analysis of single and balanced 3-phase
systems
Graphical display of voltage and current waveforms
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Power quality analysis of single and balanced 3-phase systems
Graphical display of voltage and current waveforms
128x64 Dot matrix LCD with backlight
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Energy calculation (WH and kWH)
adapter
Flexible AC current clamps: Set of 4x i2000flex
flexible AC current clamps (2000 A)
WC100 colour localisation set: 32 metal clips for
identifying cables (8 colours)
Non-interrupted harmonic analysis (V and A) to the 50th order in % and magnitude
Dual display with fast Peak Hold, Max and Min functions
Selectable CT ratios from 1 to 1000
Data logging to internal memory for up to 8000 readings with programmable logging interval
Selectable Auto power-off up to 30 minutes
Energy calculation (WH and kWH)
Transient detection of Swell, Dip and Outage
Graphical harmonic analysis (V and A) to the 50th order in % and magnitude
Analysis of % THD
Graphical phase diagram display, plus fast peak display
Maximum demand measurement over presettable time period
128x64 Dot matrix LCD with backlight
Real time clock
Programmable CT ratio from 1 to 3000 for very high power measurements
Data logging to internal memory for up to 50000 readings/32000 transient events with
programmable logging interval
Programming logging interval from 1 to 3000 seconds
Maximum demand measurement over presettable time period
Transient detection of Swell, Dip and Outage
Analysis of % THD
Graphical phase diagram display, plus fast peak display
Graphical harmonic analysis (V and A) to the 50th order in % and magnitude
Real time clock
Programmable CT ratio from 1 to 3000 for very high power measurements
Data logging to internal memory for up to 50000 readings/32000 transient events with
programmable logging interval
Programming logging interval from 1 to 3000 seconds
Type Stock no. Price per OM S$ S$ S$
OC4USB cable 493-5540a unit 1+ 307·00
Note: Colour may differ from that shown.
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
Note: Colour may differ from that shown.
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 x AA alkaline batteries
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
ac Current Range 50-60Hz True RMS, Crest Factor 4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)
Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)
Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)
Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ± 2%, 1st- 20th
4% of reading ±2%, 21st- 50th
Harmonics Iac (50/60Hz >20A) ± 2%, 1st- 20th
4% of reading ±2%, 21st- 50th
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 170mm
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 x AA alkaline batteries
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 off AA alkaline batteries
Stock no. Price per OM S$ S$ S$
697-3768 unit 1+ 770·00
Peak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar
ac Current Range 50-60Hz True RMS, Crest Factor <4 4-1500A Resolution ac current 0.01A Accuracy ac current ±1% ± 5 digits ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)
Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)
Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)
Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ± 2%, 1st- 20th
4% of reading ±2%, 21st- 50th
Harmonics Iac (50/60Hz >20A) ± 2%, 1st- 20th
4% of reading ±2%, 21st- 50th
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digits
ac Current Range 50-60Hz True RMS, Crest Factor <4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
1 (1kW - 10kW/VA/VAR)10 (10kW - 100kW/VA/VAR)100 (100kW - 1000kW/VA/VAR1000 (1000kW - 9999kW/VA/VAR)
Accuracy active/apparent power (0-1500A) ±1% ±20 digits (>20V,>20A)±2% ±40 digits (<20V,<20A)
Accuracy reactive power (0-1500A) ±1% ±20 digits (>20V,>20A)±3% ±40 digits (<20V,<20A)
Accuracy Power Factor (PF) (0.0-1.0) ±0.04 (>20V,>20A) Harmonics Vac (50/60Hz >80V) ±2%, 1st - 20th
4% of reading ±2%, 21st - 50th
Harmonics Iac (50/60Hz >20A) ±2%, 1st - 20th
4% of reading ±2%, 21st - 50th
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar
Stock no. Price per OM S$ S$ S$
697-3755S unit 1+ 1020·00
Stock no. Price per OM S$ S$ S$
697-3743 unit 1+ 445·00
2260
www.nguyenxuong.com
Energy Monitoring
Kyoritsu Power Measurement
Power Disturbance Recorders
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Hawk 5000 Electricity UsageAnalyser
6300 Compact Power Meter
www.rssingapore.com
Fluke 1710 Single-Phase Voltage QualityRecorder
300XP Thermal Printer
Fast and easy recording of voltage trends, dropouts, and
power quality – pinpoints the root cause of single phase
voltage problems
Easy to use – plus directly into the mains power socket
and capture data
Continuous recording of all values with no gaps – saves
testing time by getting the whole picture and records both
events and voltage
Clear graphical summary of data and quick overview of
key power quality parameters
Min, Max, and Average RMS values (1⁄4 cycle) with time
All necessary Power Measurements : V, A, W, VA,
Var, Wh, VAh, Varh, cos θ, In, Hz
Recording function with "integration time"
selectable from 1 second to 1 hour
The Hawk 5000 offers additional
measuring capabilities over the Hawk
3000, enabling more detailed engineering
information to be gained regarding
Portable thermal dot matrix printer for results
printout from test instruments
Text and graphics printing
Programmable header and footer text
Printing width: 46mm: paper width 57mm
9 pin RS-232C interface plus optically isolated
interface for ISO-TECH instruments
Single print and fixed interval continuous
printing modes (5, 30, 60, 300 seconds)
Size W95 x D135 x H55mm; Weight 440g (with
batteries)
Internal non volatile Memory for non-stop recording up to 10 days
Accepts Removable Compact Flash Memory up to 128MB for non-stop
recording up to 5 years
Supplied with interface software for downloading data to PC via USB
Four wiring configurations : 3 Phase 4 Wires, 3 Phase 3 Wires, single
Phase 3 Wire and 2 Wires
Wide screen with back light Multi-Display system for simultaneous
measurements
Double power supply system : from AC Line and from Alkaline battery
with approx. 7 hours of battery life
Demand function for Energy-Saving measurements
Accessories include test leads, USB cable, mains cord, compact flash
card 32MB, PC software, batteries x 6 and carrying bag
stamp – quickly identifies what happened and when
Actual transient display (>100 μs) with time stamp – identifies power quality issues quickly with
included graphical software
Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends – identifies if
the problem is power quality or equipment related
Statistical analysis of single phase voltage events - reduces analysis time by tracking event
quantities and magnitudes
Includes PowerLog software package for quick download, analysis, and automatic reporting – Save
time by generating power quality reports automatically with pre-set templates
Remote access capability via USB port to an external modem
Supplied with: 8 off AA alkaline batteries,
multinational 12V mains adaptor, thermal paper
roll, configuration software on CD-ROM &
instructions
Standards: IEC61010-1 CAT.III 600V
energy usage.
Supplied with: USB cable, PowerLog software on CD-ROM; universal power cord adapters
Instrument Compatibility
ISO-TECH IPM3005, 6200, 6300 power quality testers ISM490 solar module analyser IBT330 battery capacity tester
RS AVM-09 Anemometer
Agilent 34401A bench multimeter Measurements andparameters
Voltage, Current, Activepower,
Effect of power factor Active power : ±1.0% rdgcos θ= ±0.5 (PF=1)
Apparent power, Reactivepower,
Effective input range 10-110% of Rating range of Vand A
Active energy, Apparentenergy,
Display range Voltage : 5-120% of RatingrangeCurrent : 1-120% of Ratingrange
Apparent energy, *Reactiveenergy,
Integration time for 1/2/5/10/15/20/30 Seconds
Power factor (cos θ) recording function 1/2/5/10/15/20/30/60 Minutes Neutral current, Frequencymeter
Display update period 1 second
Wiring connections 1P 2W, 3P 4W, 3P 3W, 1P3W
Operating temperatureand humidity ranges
0-+50°C, less than 85% RH(wiithout condensation)
Voltage ranges 150.0 / 300.0 / 600.0V AC Storage temperatureand humidity ranges
-20 to+60°C, less than 85%RH(without condensation)
Voltage accuracy ±0.3 % rdg ±0.2 % fs[4565Hz]
Over load protection Voltage : 720V AC rmsCurrent : 600A AC rms (withClampsensor MODEL 8125)
Current ranges 50.00/100.0/200.0/500.0 A AC(with Clamp sensor MODEL8125)
PC communicationInterface
USB
Current accuracy ±0.3 % rdg ±0.2 % fs +Clamp sensor accuracy [at45-65Hz]
CF card Interface Compact flash card (Standard type 32/64/128MB)
Crest factor Voltage : up to 2.5 Current :up to 3.0(with 90% fs or less)
Safety standard IEC61010-1 CAT.III 600V
Frequency meter range 40-70Hz Power supply AC Line : 100-240V±10% (50/60Hz) DC Battery 9V : LR6×6(Battery life approx. 7h)
Frequency meter accuracy ±3dgt Power consumption 10VA (MAX) Active Power accuracy ±0.5 % rdg ±0.2 % fs +
Clamp sensor accuracy [at45-65 Hz]
Dimension 175(L)×120(W)×65(D) mm
Accuracy precondition PF=1, Sine wave, 23°C±5°C Weight Approx. 800g (includingbatteries)
Single or 3 phase power kW, kVA and current
Power factor and phase angle
Total kVAr regardless of phase angle
True rms current measurement (3-phase)
True rms voltage (single phase)
Contact RS for calibration requirements
Single phase frequency
Software supplied with the Hawk 5000 enables configuration, on line monitoring, data collection
and analysis with colour graphics.
Safe simple operation requires no connection to live terminals
Status indicators confirm correct operation and guide user for current transformer placement
Phasing wand can be used to ensure correct phase allocation for the CTs
Pulse measuring capability (2 channel) enables logging from remote meters, or fluid flow meters
System accuracy better than 2% ± 1% of range with supplied current transformers
High data capacity enables monitoring for periods between 7 weeks and 38 weeks (dependant
upon detail and logging parameters selected)
Hawk Reporter Pro tariff analysis software for analysis and presentation of survey results in
detailed format
Operating voltage 70 V to 300 V Flickermeasurement
EN 61000-4-15
Min/Max/Avg RMSvalue
Resolution 0.125 V Number ofrecording channels
1 Phase to Neutral2 Phase/Neutral to Ground
Number of events 175,000 Recording time 1 day to 339 days depending onaverage time from 1 second to 20minutes
Dips/Interruptions Yes Transients Yes (>100μs) Time resolution 5 ms Frequency range 50 Hz ± 1 Hz and 60 Hz ± 1 Hz Voltage resolution 0.125 V Power cord
adapterscompatibility
Australia, Central America, Europe,Ireland, Italy, Japan, Malaysia, NorthAfrica, Singapore, Switzerland, UK, US
Over-voltages Yes Safety categoryrating
CAT II 300 V
Frequency Yes Size 23 x 19.75 x 22.2 cmHarmonicsmeasurement
EN 61000-4-7 (up to 32nd)
Type Thermal Printer Dimensions (W)95 x (D)135 x (H)55 mmInterface RS-232C Weight 440 g
Stock no. Price per OM S$ S$ S$
627-8782 unit 1+ 3060·00
Stock no. Price per OM S$ S$ S$
435-601 unit 1+ 1656·00
Stock no. Price per OM S$ S$ S$
697-3787 unit 1+ 370·00
Note: Optional individual 200A CTs are also available to give improved accuracy when monitoring low
current loads.
Accessories
Supplied with: Hawk reporter Pro software on CD-ROM,carry case,3 x 1000A current transformers, 3
x colour coded CT leads, phase probe, RS-232 cable and operators manual
Description Stock no. Price per OM S$
Thermal Paper Roll 671-5890 unit 10+ 6·70
2261
www.nguyenxuong.com
Seaward Portable Appliance Testers
Safety Testing Software
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
PrimeTest 300
Safety 1st Xpress
Portable appliance testers are used for periodic testing of appliances in the place where they are used
(as required by Health and Safety legislation) and for regular safety testing of appliances for hire,
repair or re-sale (as required by equipment safety regulations).
Fluke 1735 Power Logger
Fluke 435 Logging Power Quality Analyser
Lightweight battery powered hand-held tester
incorporating all Class I and Class II required
Combines the ease of use of earlier software products with
modern Windows presentation standards such as tree and
tabular view, filtering and drag and drop, to make the most
productive of this type of software on the market. The system
is designed to ensure compliance with Health & Safety
legislation whilst keeping administration costs to a minimum.
Uses database technology to hold a register of equipment, a
history of test results and a forward schedule of testing
requirements. A full template for Portable Appliance Testing
(PAT) is included in the software with the added feature of
test records of any other equipment such as ladders, lifting
tackle, cooling towers, emergency lighting, fire extinguishers,
in fact, any equipment that needs regular test.
The Fluke 435 three-phase power quality analyser helps
users to locate, predict, prevent and troubleshoot problems
in three and single phase power distribution systems.
Troubleshooting is faster with on-screen display of trends
and captured events, even while background recording
continues. The new IEC standards for flicker, harmonics and
power quality are built right in to take the guess work out of
power quality.
The Fluke 1735 Power Logger is the ideal electrician or
technician’s tool for conducting energy studies and basic
power quality logging. The 1735 can be set up in seconds
with the included flexible current probes and color display.
The meter is able to log most of the electrical power
parameters, harmonics and captures voltage events as well.
Troubleshoot real-time: Analyse the trends using the
cursors and zoom tools – even while background
recording continues
Highest safety rating in the industry – 600V Cat IV / 1000V
electrical safety tests.
Bluetooth technology enables the wireless connection of bar code
scanners & label printers allowing connection-free testing and data
transfer directly from the tester to a PC-based record keeping systems at
the touch of a button.
Key Features:
On screen graphic display for each reading
Unique screen presentation for assets - assets can be listed, several to a page with all fields shown
in a neat line format
Unique keyboard interface reduces the dependence on mouse operation
Automatic updating of standard tables on data entry
Use of short codes for key data
Generates unlimited ’reader’ systems from the licensed system
Journal system providing the ability to record events such as visits and an asset journal which
complements the test history
Asset tracking - an automatic journal entry is created when an asset is moved from one location to
another
Adaptable to each clients requirements
Prints straight from the screen
Batch input of test results
Group change facility allowing sweeping of asset register updating selected fields with specified
data
Library of downloaded files
Archiving and retrieval routines
Will accept and convert data from the Safety 1st DOS version/Safety 1st plus DOS/Windows version
Compatible with all popular PAT testers including download PAT testers:- Seaward Supernova,
Europa, 2000, 20001, 2000iee, 1000, 1000X, 1000S, SEN60204; Metrohm MicroPAT+; Robin Smart
PAT 5000 and SmartPAT 5500
CAT III
Automatic transient mode captures 200kHz waveform data on all phases simultaneously – up to
6kV
Measure all three phases and neutral with included 4 current probes
AutoTrend: Every measurement seen is always automatically recorded, without any setup
System-Monitor: Up to seven power quality parameters on one screen according to EN50160
In-rush mode for troubleshooting nuisance circuit breaker tripping
Seven hours operating time per charge on NiMH battery pack
View graphs and generate reports with included analysis software
Fully Class A Compliant - conduct tests according to the stringent international IEC 61000-4-30 Class
A standard
Logger function - Configure for any test condition with memory for over 400 parameters at user
defined intervals
Large white backlit graphics display, plus full alphanumeric keypad
Intuitive and fast user interface
Manual and automatic test modes
Programmable soft keys for customised test routines.
User definable and configurable test sequences
Large memory for storing upto 20000 results and test programs
Download / Upload to software
Records asset location and non-electrical test results with customised
System Requirements: IBM PC compatible with 64MB RAM, Pentium II 350MHz processor and high
speed hard disk, CD-ROM drive, Windows 95/98, Windows supported printer. For multi-user
applications it also requires an NT workstation and local area network supporting Windows.
Supplied on CD-ROM.
Record power and associated parameters for up to 45
days
Monitor maximum power demand over user-defined
averaging periods
screen prompts
Large internal memory facilitates the storage of test results for safety audit and traceability
purposes.
In addition to test results, the tester can also record other details and descriptions of the equipment
under test
Prove the benefit of efficiency improvements with energy consumption tests
Measure harmonic distortion caused by electronic loads
Improve reliability by capturing voltage dips and swells from load switching
Easily confirm instrument setup with color display of waveforms and trends
Measure all three phases and neutral with included 4 flexible current probes
View graphs and generate reports with included Power Log software
Compact, rugged design with IP65 case, 600 V CAT III.
View graphs and generate reports with included analysis software
Note: Not all features are available on all testers. Contact technical helpline for further information
Supplied with:
Stock no. Price per OM S$ S$ S$
423-9448 unit 1+ 1570·00
Supplied with:
Hard carrying case with rollers
4 Flex current probes (i430-flex)
5 Test leads and clips
Battery charger
Optical USB cable
Color localization set
Printed getting started manual
User manual CD
FlukeView software
Power Log software
Associated accessories available separately:
Stock Nos:470-2261, 456-1256, 475-1409, 409-9341, 409-9329, 613-1295, 613-1302, 613-1318, 613-1346,
497-498, 445-3846, 450-5969, 514-4824, 513-7056, 399-634, 513-7090 & 513-7078.
Supplied with: Test lead, mains lead, 110V socket adaptor, USB/Bluetooth adaptor with driver
software on CD-ROM, 6 off rechargeable NiMH AA batteries, mains battery charger, 30-day PATGuard
evaluation disk, reference guide, instruction manual on CD-ROM, carry case.
Soft carrying case
4 flexible current probes (15 A/150 A/3000 A)
Power Log software
Voltage leads and clips
Color localization set
PC interface cable
Universal AC adapter
Printed English manual
Multi-language manual CD
Contact RS for calibration requirements
Earth Bond Test Differential Leakage
Output Current (Load 2) : ± 200mA DC Test Voltage: 230V +10%, -15% Test Voltage (o/c): > 4VDC Maximum Load current: 13A rms Test Duration: Programmable within a
maximum limit Test Duration: Programmable within a
maximum limit Measuring Range: 0.01Ω - 19.99Ω Measurement Range: 0.25 - 19.99mA Operating Error: ±5% + 2 counts Measurement Resolution: 0.01mA Measurement Resolution: 0.01Ω Operating Error: ±5% of rdg +2 digits Pass Value: User defined Pass Value: User defined Insulation Test Touch Leakage
Test Voltages: 500VDC @ 1mA nominal Test Voltage: 230V +10%, -15% Test current: >1mA into 500k.; < 2mA into
s/c Maximum load current: 13A rms
Test Duration: Programmable within amaximum limit
Test Duration: Programmable within amaximum limit
Measurement Range: 0.10 MΩ - 40MΩ Measurement Range: 0.10 - 3.50mA Operating Error: ±5% +2 digits Measurement Resolution: 0.01mA Measurement Resolution: 0.01MΩ (Max) Operating Error: ±10% of rdg +2 digits Pass Value: User defined Pass Value: User defined
Stock no. Price per OM S$ S$ S$
627-5727 unit 1+ 14501·00
Contact RS for calibration requirements
Description Stock no. Price per OM S$ S$ S$
Hawk 5000 436-471 unit 1+ 6150·00
200A ac CT 436-516 unit 1+ 245·00
RCD Test Test Current: 30mA rms sinusoidal Test Voltage: 230V +10 %, -15 % Test Current Accuracy: +10, -0 %
Stock no. Price per OM S$ S$ S$
627-5711 unit 1+ 5508·00
2262
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
Supernova Xe 240V Computerised PAT
Dual Voltage Computerised PAT
PrimeTest 350 (UK)
The Seaward Supernova XE Portable Appliance
Tester is a powerful, lightweight tool, to assist in
the analysis of the safety of 240V portable
A powerful instrument designed to test 240V
and 110V appliances (from a 240V supply),
incorporating the new industrial design the
Lightweight battery powered PAT tester
incorporating all Class I and Class II required
instrument features a flip down keypad and lead storage,
with full graphics display that offers HELP screens and in
built training guidance, a full QWERTY keypad and softkeys
for instant test selection. Tests can be carries out on both
automatic or manual mode on both 240V and 110V, class 1
and class 11 appliances, including business and IT
equipment.
electrical and electronic equipment. A range of tests are provided,
with innovative features to aid difficult test situations, which allow
testing of a wide variety of equipment.
electrical safety tests.Bluetooth technology enables the wireless connection
of bar code scanners & label printers allowing fast, efficient testing and
results recording.,The PrimeTest 350 can complete alternative leakage test,
250V insulation test (for use when suppressors or other components
prevent a 500V insulation test) and load measurement. During the
protective conductor and touch current tests, the load is measured and
displayed as both a power and current measurement.The PrimeTest 350
PAT tester is a ’facilities management tool’ because through
data logging and capture, it also records the location of the assets – helping
to meet requirements of health and safety standards.
IEC lead test, safety earth test, earth screen test, earth
continuity test, insulation test, subsititue leakage test,
flash test, touch voltage, load test, leakage test and visual
Stores up to 2400 results including, appliances, location, site,
date and time in non-volatile flash memory
Accurate earth bond and leakage measurement even when
multiple earth paths exist
Full QWERTY keyboard with fast keys
Full graphics display, real-time clock
Connects to PC, barcode reader and printer
Software adjusts the user interface to differing levels of
Large white backlit graphics display & full alphanumeric keypad
Intuitive and fast user interface with manual and automatic test modes
Programmable soft keys for customised test routines.
inspection log
Unique earth bond and leakage test, that means accurate earth bond and leakage measurements
Boot up in less than 3 seconds with a full memory check
1,200 test integral memory, storing the history of appliances with technical notes, storing data by
customer, location and site. Stores test codes by appliance type and name
Automatic test code generation
Automatic or user defined pass/fail settings
Control using the most versatile user interface on the market, featuring ’learn mode’ software that
can adjust the interface to suit users of differing levels of expertise
Real time clock
Remote control earth and insulation test probe with pass/fail indication
Flash memory, that means the end of battery backup
Serial and parallel printer output for bar codes, test certificates and test reports
Test results may be downloaded to a PC running Safety 1st or Safety 1st Plus software
expertise
Auto testcode generation
Fast start-up less than 8 seconds
Superfast download up to 10 times quicker than existing testers
Compatible with the Seaward BrainCell equipment tagging system and Test N’ Tag label printer
Test results may be downloaded to a PC running, PATGuard, Safety 1st or Safety 1st Express
Rechargeable batteries with 4 hour recharge time via charging port eliminates the reliance on
mains supply, reduces downtime between tests and makes the instrument practical and portable to
use anywhere.
User definable pass / fail limits and configurable test sequences
Tests performed: Earth continuity, insulation resistance, substitute leakage, power socket wiring
check, protective earth (PE) conductor current, touch current & RCD trip time.
Memory for storing typically 8500 records
Download / Upload to Seaward PATGuard software (available separately)
Large internal memory facilitates the storage of test results for safety audit and traceability
purposes.
In addition to standard electrical safety tests, test records for items such as fire extinguishers,
emergency lighting & microwave ovens can be created and stored. The records can be
downloaded to PATGuard Software for complete traceability
Software utility supplied to upload Company logos from a PC to the tester to incorporate in test
label printout
Compatible with :
Seaward Test N Tag Elite Bluetooth Printer stock no. 461-076
Seaward bluetooth barcode scanner stock no. 461-098
Seaward PatGuard software stock nos. 613-1295, 613-1302, 613-1318 and 613-1346
Note: Compatible with Test ’N’ Tag printer stock number 456-1256
More associated accessories available separately see
Stock Nos: 497-498, 445-3846, 450-5969, 514-4824, 513-7056, 513-7090 & 513-7078.
Note: Options of instrument with UK power lead, or Aus/Nz lead.
Earth Continuity Output currents into 0.1 0hm 100mA, 4A, 10A, 25A ac
Test voltage 6V rms o/c
Ranges 0-2 Ohms, 0-20 Ohms
Accuracy +/-5% of reading +/-2 digits
Resolution 0.01 Ohms selectable (continuity variable)
Pass range Selectable (continuously variable)
Misc 4-wire measurement, floating earth
Insulation test Measuring range 50K-300M Ohms
Test voltage 250V, 500V, DC (0%, +20%)
Accuracy +/-5% reading +/-2 digits
Resolution 0.01M Ohms (>10M Ohms)
Subsititute Leakage Voltage 40V ac nominal at 230/115V supply
Range 100uA-20mA
Resolution 0.01 mA
Accuracy +/-5% reading +/- 2 digits
Pass range Selectable
Flash test Voltage class I 1500V
Class II 3000V +/-10% at 1mA at 230/115V supply
Load test Voltage measurement 90V-300V
Current 0.16A ms
Leakage Range 100uA-10mA
Resolution 0.01mA
Accuracy +/-5% reading +/-2 digits
Pass range Selectable
IEC lead test Test performed Earth continuity, Insulation
Polarity check Yes
Operating voltage Voltage range 103V - 126V, 207V-253V
Frequency 45Hz-65Hz
Test voltage/currents are nominal at 230/115v supply
For a complete kit with a saving over buying the options separately see PrimeTest 350PAT solution package RS stock no. 461-086
Supplied with: Operating manual, earth & insulation test probe, mains lead with UK 13A mains plug
or Aus/Nz depending on model.
Description Stock no. Price
per
OM S$ S$ S$
Seaward SuperNova 2000 342-8805 unit 1+ 3690·00
Supplied with: Carry case, mains lead,1.2m test lead and crocodile clip, IEC test lead, battery charger,
6 LR6 NiMH rechargeable batteries, instruction manual, utilities CD-ROM,RS232 to PC cable, RS232 to
USB adaptor, & 110V/230V socket adaptor, 30-day PATGuard evaluation disk. Earth Bond Test Test Voltage* 6V nominal (no load)
Test Current* 4A, 10A, 25A selectable (into s/c load)
Range 40mΩ - 19.99Ω
Resolution 0.01Ω
Accuracy ± 5% of reading,± 2 digits
Pass Levels Selectable
Misc 4-wire measurement, floating earth
DC Earth Bond Test Test Voltage* 4V nominal (no load)
Test Current* -200mA, +200mA selectable (into s/c load)
Range 40mΩ - 19.99Ω
Resolution 0.01Ω
Accuracy ± 5% of reading,± 2 digits
Pass Levels Selectable
Misc 4-wire measurement, floating earth
Earth Screen Test Test Voltage* 100mV nominal (no load)
Test Current* 100mA (into s/c load)
Range 40mΩ - 19.99Ω
Resolution 0.01Ω
Accuracy ± 5% of reading,± digits upto 5.00Ω
Pass Level Selectable
Misc 4-wire measurement, floating earth
Insulation Test Short Circuit Current 2mA dc maximum
Measuring Range 100kΩ - 100 MΩ
Resolution 0.01 MΩ
Test Voltage* 500V dc or 250V dc nominal (0.5MΩ load)
Accuracy ± 5% of reading, ± 2 digits (100kΩ - 20MΩ)
Pass Levels 0.5MΩ, 1.0MΩ, 2.0MΩ, 4.0MΩ, 7.0MΩ
Leakage Range 0.1mA - 10.0mA
Resolution 0.01mA
Accuracy ± 5% of reading, ± 2 digits
Pass Levels 0.25, 0.5, 0.75, 1.5, 2.25, 2.5, 3.0, 3.5 & 9.9mA
Load Test Voltage Measurement 90 - 300V Indication only
Current 0 - 4kVA Indication only
IEC Lead Test Test Voltage* 40V ac
Detects Open, Short, Good, Reverse
* Test stimulus based on mains supply of 230V, varies with supply voltage.
Test Current Phase: 0°/180° auto switched onalternate cycles
Measurement Resolution: 0.1Ω (Max)
Test Duration: 2000 ms maximum if RCDdoes not trip
Lead Test
Measuring Range: 10ms - 2000ms Test voltage: 9 VDC Operating Error: ±10 % Test Duration: 2s Measurement Resolution: 1ms Test: Live / Neutral Checks for
o/c, s/c and crossed Earth Loop Resistance Test Power Socket Test
Test Voltage: 230V +10 %, -15 % Input voltage range: 230V +10 %, -15 % AC Test Current: Such that it will not trip at
30mA RCD Indicators: phase to earth voltage
phase to neutral voltageneutral to earth
Measuring Range: 1Ω - 199Ω Dimensions 208 x 110 x 60 mm Operating Error: ±10 % +2 digits Weight 1.52 kg
Stock no. Price per OM S$ S$ S$
717-3647S unit 1+ 2722·00
Description Stock no. Price per OM S$ S$ S$
PrimeTest 300, Aus/NZ 163-851 unit 1+ 3900·00
2263
www.nguyenxuong.com
Seaward PAT Tester Accessories
Fluke Portable Appliance Testers
Megger Portable Appliance Testers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Test n Tag K3100 Bluetooth Adaptor
Seaward CCD Barcode Scanner
Test ’n’ Tag PAT Label printer
6200 Manual PAT Tester
PAT4DV & PAT4DVF Dual VoltageTesters
PAC3760 Plus Aus/NZ
Aust/NZ PAT - Seaward PAC3760
Compact and light weight portable appliance tester suitable for
testing both 230V and 110 V Class I and II appliances. Ideal for
manual testing and low volume applications.
These microprocessor controlled instruments are designed
for maximum flexibility coupled with ease of use. They carry
out routine safety tests on both 110V and 230V portable
appliances and extension leads. The LCD display shows full
details of clients and appliances which have been uploaded
from data storage and which can be downloaded
subsequently to a PC for certification and storage.
Dedicated key for each test for ’one-touch’ testing
Pre-set pass/fail levels to save time
Large backlit display for easy reading
Internal memory to store 100 tests
Separate IEC socket for easy mains/extension lead testing
Detachable test leads for quick field replacement
The Test ’n’ Tag PAT label system prints durable
synthetic tags immediately after the Portable
Appliance test. It replaces the need for
The PAC3760 is a next-generation PAT tester
designed specifically for standards AS/NZS
3760:2003
Connects to the Seaward Test ’N’ Tag model
K3100 printer to enable wireless Bluetooth
communication with the Seaward PrimeTest 300
Non-contact CCD barcode scanner for rapid
entry of appliance number, test codes and
asset ID details .
Circuit test checks appliance is not open circuit or short
circuit
Earth Continuity test in accordance with EEA
recommendations for IT Equipment
Simple Pass/Fail indication and automatically conducts a sequence of tests
Unique 3 button operation, class I, class II and leakage
Automatically detects if the unit under test is switched on
Auto-sense of IEC leads and extension cords
and Primetest 350 handheld PAT tester.
Earth bond low (low/high current)
Insulation 500 V
Leakage (PE current, touch current, substitute current)
Can test 110 V appliances (earth bond, insulation) via the 110 V adapter (Fluke TA700 rs 512-5766)
240V equipment load test
Supplied in a protective hard carrying case with extra storage space for accessories and other tools.
RS-232 port for printing test results
9 Way D type connector
Directly compatible with Seaward PATS :- Supernova
Plus, Supernova Plus Xe, Supernova, Europa Plus,
PAT,Europa Plus PAT, PAT2000i, PAT2000iee
Compatible with the Seaward PrimeTest 300 via Barcode
Scanner Bluetooth Adaptor (stock No. 513-7078)
Popular and easy-to-use appliance tester now
upgraded with more features.
handwriting any test labels and saves time by fully
automating the PAT testing process.
Designed to work with the Seaward Europa Plus, Supernova
Plus and Supernova Xe PAT testers.
Insulation test at 500V d.c., into 0.5MΩ load or greater with user settable pass bands
Earth Leakage test measures earth leakage via differential method to cover multiple earth paths
Fuse Test to check for blown fuses
Flash test (ON DVF ONLY)
Visual checks
Stores up to 1000 test results with full client and asset details including descriptions for download
to a PC
Full details can be uploaded from PC storage for on site history during retest
Alphanumeric keypad
Serial connection for PC and serial printer
Parallel printer connection
Compact thermal transfer printer
Portable and lightweight
Security and accuracy of information is assured as test
details are direct from the tester’s memory
Stock no. Price per OM S$ S$ S$
500-2865 unit 1+ 1350·00
Class I & II appliances, Class I leads and powerboards
Leakage test for Class I and Class II appliances
10mA & 30mA RCD trip-time test
3 phase insulation & leakage testing with optional adaptors
Battery or mains power operation
Full readings displayed with Pass/Fail indication
Bluetooth communication range up to 10m
Power on and Bluetooth LED indicators
Bluetooth connection LED indication
RJ11 communication interface to printer
DC power supply lead to derive power from the Test ’N’ Tag
printer
Unit is a Bluetooth server module
For a complete Fluke 6200 manual PAT tester solution with a saving over buying the options
separately, a 6200 kit is available comprising:
Stock no. Price per OM S$ S$ S$
514-4824 unit 1+ 680·00
6200 tester with standard accessories and hard case
EXT100, Extension lead test adaptor
560 appliance pass labels
100 appliance fail labels
Register for PAT (Log Book)
Description Stock no. Price per OM S$ S$ S$
PAT4DV AU 163-980 unit 1+ 3080·00
PAT4DVF AU 163-996 unit 1+ 3670·00
Supplied with: Carry Case, Earth Bond Lead, Mains Supply Test Lead, IEC Lead &
Training DVD.
Own company name can be customised onto the labels.
Label design includes a barcode, asset number, test date and next test date
Label size approx. 6cm long and 2cm wide
Industrial tape cartridges 25.4mm wide by 12m long are available separately
Dimensions (LxWxH): 152 x 95 x 100
For Compatible black on yellow tape cartridge, RS Stock No. 475-1409, black on white RS Stock No.
539-0998
Stock no. Price per OM S$ S$ S$
399-634 unit 1+ 375·00
Associated accessories
Display Backlit LCD grahics
Indication Pass/Fail, Measurement Value
Enclosure rating IP40
Overvoltage Category CAT II 300V
Electrical Safety IEC61010-1:2001, IEC61326:2005
Dimensions 265 x 110 x 55mm
Weight 800g
Supplied with: Seaward serial port lead and 14Vdc 1.6A mains adaptor
Type PAT Tester Download No Supply Voltage 230 V ac Flash Test No Test Type Class I and II
SP1000, EXT100 & TA700 (see the ’6500 Auto-Test PAT Tester’ for details)
Note: Options of printer with UK or Aus/Nz mains lead
Type Stock no. Price per OM S$ S$ S$
PAT Tester 712-6020a unit 1+ 1128·00
Supplied with: Hard carry case with test lead, test probe, crocodile clip, UK 230V mains lead and
instruction manual.
Description Stock no. Price per OM S$ S$ S$
Test ’N’ Tag Printer BS1363 456-1256 unit 1+ 790·00
Test ’N’ Tag kit, black onyellow cartridge
475-1409 unit 1+ 91·00 3+ 87·50
Test N Tag cartridge blackon white
539-0998 unit 1+ 86·00 3+ 82·50
Description Stock no. Price per OM S$ S$ S$
Supernova Xe (Aus/NZ) 537-2625 unit 1+ 4090·00
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
712-5976S unit 1+ 2147·00
2264
www.nguyenxuong.com
Port.Appliance Checkers
Kyoritsu Portable Appliance Tester
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
Seaward PrimeTest 100 (UK)
Kyoritsu Kew 6201A
Contractor PAT & ElectricalCertification Software
PAT400 Series DownloadingPortable Appliance Testers
PAT300 Series Portable ApplianceTesters
Powersuite Professional Contractor offers all the features of PowerSuite
Lite with the addition of a data based client, assets and results
management database for managing 17th Edition electrical and Portable
Appliance test results. All records and downloaded data is allocated to the
appropriate customer on which a number of reports can be run
Performs 4 test functions to ensure safety of Class I
and Class II appliances
Readings displayed on large, clear LCD with pass or
Portable desktop appliance testers providing manual or
automatic electrical equipment safety testing in accordance
with DIN VDE 0701-0702.
Easy to use handheld tester with the
functionality of a PAT checker, an IEC lead and
fail indication
Available in Australia/New Zealand and Singapore versions
Large 5.7in. ¼ VGA backlit colour
screen for clear & easily
understandable results
5 user defined soft-keys for direct
access to frequently used functions
Full QWERTY keypad for easy and
precise data entry.
10,000 record memory for
interruption-free testing.
USB port for quick download to a
memory stick eliminating the need
to take the tester back to the office
every night, data is directly
compatible with Megger PowerSuite
Work in real certificates and forms
Client and results database manages links between customers and their
test results
Download test results from Megger downloading PAT testers, Megger
downloading electrical installation testers and third party test equipment
or direct data entry to certificates
Real time results transfer via Bluetooth with Megger MFT1553 electrical
installation tester
Import company logo and add header page to customise certificates for
250V and 500V insulation tests & 200mA continuity test
Differential, substitute & touch current tests with 10 μA
resolution
High resolution backlit colour screen with all test details
displayed before, during and after testing
Tests standard, RCD protected and anti-surge extension
leads
Instant re-start for faster testing across multiple rooms
Pre-defined test sequences
Adjustable test pass limits and adjustable test duration
times
Standards: IEC 61010-1 CAT III 300V pollution degree2, IEC61326-1, AS/NZS 3760
software.
2 USB ports for optional barcode reader & printer
Selectable PASS/FAIL limits provide instant indication of a faulty asset
200 mA continuity test
250 V and 500 V insulation tests prevents damage to sensitive electronics
Instant re-start for fast testing across multiple rooms
Tests for standard, RCD-protected and anti-surge extension leads
Interrupt-time tests for portable or plug-in RCDs
Adjustable test times allow faster testing for increased productivity
Differential, Substitute or Touch leakage current tests
Operational test with VA display
a professional appearance
Print on plain paper or pre-printed forms
Extensive range of certificate formats and supports IEE, NICEIC, ECA, SELECT and ELECSA and BS
electrical test certificates
Full range of PAT testing certificates including repairs cerificates
Reports module generates a wide range of reports for electrical installation testing and PAT testing.
Project billing certificates and reports
Digital imaging module allows picture import for increased clarity in reports
Organiser module for scheduling workload, site work and retesting etc. with graphical diary
Extended forms offer alternative and extra certificate formats including filling stations and security
systems, ensuring there is a certificate to meet your requirements
Push-button operation for test groups or individual test functions
Test results are marked as a PASS or FAIL, and compared to the pass/fail limits for each test
indicating a good or marginal result
Selectable PASS/FAIL limits
Direct testing of IEC power cords with no adapter
Supplied with: Power cord, 7129 test leads, 7101 flat test bar, 7140
adapter, probe case, shoulder strap & manual
PAT320 only:
PAT410 Features:
Note: System Requirements: Pentium IV PC running XP or Vista operating system; 128MB RAM
(Min); 100MB hard disk space; CD-ROM drive; COM1 RS232 port (or USB port with USB to RS232
adaptor) for use with downloading PAT testers; Bluetooth for use with Megger MFT1553
Light weight, low current Portable Appliance Tester, configurable for fast testing and high
productivity.
230V operation & testing
Conductor Resistance Test Measuring current 2.5mA dc or less Measuring Range 0 - 15.00 Ω Accuracy ± (2% rdg +3 dgt) Resolution of measurement 10 MΩ Leakage Current Test
Open circuit voltage <12 Vac Measuring Range AC 0.1 - 19.99 mA Measuring current 10 Aac nominal value Resolution of measurement 0.01 mA Accuracy ± (3% rdg +5 dgt) Examination time Max 15s Insulation Resistance Test Accuracy ± (3% rdg +5 dgt) Rating 250 V / 20 MΩ Mains Voltage Check
Measuring Range 0 - 19.99 MΩ Measuring Range 207 - 264 Vac Resolution of measurement 10KΩ Resolution of measurement 1 V Output voltage 25 0Vdc (+20% / -10%) @ 1MΩ Accuracy ± (2% rdg +3 dgt)
Stock no. Price per OM S$ S$ S$
667-8359 unit 1+ 1090·00
10A & 25A High current test capability
Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document
wallet, bond/continuity test lead with croc-clip and probe.
Description Stock no. Price per OM S$ S$ S$
Kew 6201A Aus/NZ 410-703 unit 1+ 1100·00
Kew 6201A SG ver 543-273 unit 1+ 880·00
PAT420 Features:
Bond Test (PAT320 only) Touch Current Test
Test voltage 9Vac nominal Test Voltage Mains 115/230Vac,50/60Hz
10A Test 10A rms ±20% nominal Display Range 0 → 5mA
26A Test 26A rms ± 5% nominal Accuracy ±5% ± 30μA
Display Range 0 → 1.99Ω Resolution 10μA
Accuracy ±5% nominal Operational Test
Resolution 1mΩ , 10mΩ Test Voltage Mains 115/230Vac
Continuity Test Display Range 0 → 4KVA.
Test Voltage +4.5Vdc ± 10% Accuracy ±5% nominal
Test Current ±200mA ± 10% Resolution 1VA � 10VA
Display Range 0 → 19.99Ω Displays Load VA, voltage and current
Accuracy ±5% nominal Extension Lead Test
Resolution 1mΩ, 10mΩ Tests Insulation and Bond tests
Insulation Test Polarity Test Lead OK; LN S/C;
Test Voltage 250Vdc, 500Vdc nominal LN Reversed; L/N O/C
Display Range 0 → 100MΩ Portable RCD test
Accuracy ±2% , ±5% nominal Test Current Accuracy -8% to –2% (½ x I)
Resolution 10KΩ, 50KΩ +2% to +8% (1 x I, 5 x I)
Substitute Leakage Test Trip Time Display Range 0 → 1999ms (½ x I)
Test Voltage 40Vac ±5%, 50/60Hz 0 → 300ms (1 x I)
Display Range 0 → 19.99mA 0 → 40ms (5 x I)
Accuracy ±5% ± 100μA Accuracy ±1% ± 5 digits
Resolution 10μA Resolution 100μs
Differential Leakage Current Fuse Test
Test Voltage 115/230Vac, 50/60Hz Display OK, Open Circuit
Display Range 0 → 19.99mA
Accuracy ±5% ± 100μA
Resolution 10μA
Dual 230V and 110V operation and testing for industrial, commercial and residential applications
10A and 25A bond test with high duty cycle and no overheating on repetitive tests
Description Stock no. Price per OM S$ S$ S$
PAT320 BS1363 712-5755S unit 1+ 1952·00
PAT450 Features:Dual 230V and 110V operation and testing for industrial, commercial and residential applications
10A and 25A bond test with high duty cycle and no overheating on repetitive tests
Flash test at 1.5kV and 3kV, ideal for industrial, tool hire and service workshops
Accessories
Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document
wallet, IEC C6 to C13 plug adaptor, bond/continuity test lead with croc-clip and probe, High Voltage
probe(PAT450 only)
Description Stock no. Price
per
OM S$ S$ S$
415V 5-pin to BS1363 AdaptorLead
666-6081 unit 1+ 98·00
415V 4-pin to BS1363 AdaptorLead
666-6088 unit 1+ 98·00
Description Stock no. Price per OM S$ S$ S$
PAT 410 Aus/NZ 721-2461a unit 1+ 2908·00
PAT 420 Aus/NZ 721-2465a unit 1+ 3283·00
2265
www.nguyenxuong.com
Flash/Hi-Pot Insulation Testers
Appliance Servicing Tester
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Fluke 1550, 1555 5kV and 10kV InsulationTester
MIT510/2 & MIT520/2 5kVInsulation Testers
My Account
www.rssingapore.com
MT204-S Machine TesterTests to the requirements of European standard IEC/EN 60204 and
the German standard DIN VDE 0113 part 1.
Earth bond resistance measurement, test current 10 A or 0,2 A
Loop-/ Line impedance measurement up to 440 V with display of
prospective short circuit current PSC
Insulation resistance measurement with 250 V or 500 V
Residual voltage test, display of discharge voltage or discharge time
Integrated high voltage test with 1000Vac can be deactivated via key
switch
Measurement memory for approx. 2000 values
Integrated interface (USB 2.0) for transferring measurements to PC
Separate interface (USB 2.0) for connecting a barcode scanner, USB
keyboard or USB key
Graphical LCD for measured values, limit values and parameters
Easy to use by rotary switch and START/STOP button
5kV insulation resistance testers in a rugged IP65 case to
enable simple safety checks on insulation and also a range
of predictive tests for preventative maintenance.
Safety features include automatic discharge of capacitive
energy, test inhibit if >50V detected at test leads and timed
start button to prevent inadvertent operation if button is
jammed etc.
High voltage insulation tester ideal
for testing high voltage equipment
including switchgear, motors,
generators and cables.
Meets requirements of IEEE 43-2000
Capacitance and leakage current
measurement
Resistance measurements up to 2TΩ
(Fluke 1555)
Ramp function for breakdown
testing
Voltage breakdown detection alerts
and voltage reading up to 600 V ac or
dc for increased user safety
extension lead tester and a power socket polarity checker.
One pair of sockets for all measurement tasks
EN61010 safety rating CAT IV 300V, CAT III 600V
Easy data entry barcode scanner (RS 700-7803) and USB keyboard (RS 704-7390) are available as
optional accessories.
5kV dc test voltage, 3mA short circuit current
Automatic IR test
15TΩ resistance range
Guard terminal for enhanced accuracy (guard test lead
supplied)
99 measurements storage and recall and PC interface
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)
Timer settings up to 99 minutes for timed tests
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large LCD display with analogue bargraph
Long life lead acid battery with over 750 tests between charges
EN 61010 safety rating CAT IV 1000 V, CAT III 1000 V
Battery powered with mains supply for power or battery recharge
Operating temperature range -20°C to +50°C
Digital/Analogue backlit display
Voltage, leakage current, capacitance, time constant display
99 minute count up timer
Complies with EN61010-1 Cat IV 600V
Quick reference guide inside the lid
Supplied with: Compact carry case, mains lead, 2 x 2m safety test leads, 2 x 10m extension test leads,
2 crocodile clips,1 interface cable and user manual
Two electrical safety checks in one tester
6 automated test sequences
Checks appliance safety and socket safety
Simple pushbutton test sequence giving for Class I, Class II, Leakage
and Lead tests
LCD display giving clear PASS/FAIL indication
Tests Class I and II equipment including IT and business equipment
Differential Leakage test
Extension and IEC lead tests
Power socket polarity
Detects load of appliance under test to check for power switches
which are off and/or appliances which may draw excessive current
Supplied with: Test cables & crocodile clips, infrared USB adaptor, AC power cord, 12V lead acid
battery (fitted), FlukeView Forms Basic Software, user manual on CD-ROM, soft carrying case (Fluke
1555 only)
Fluke 1550 & 1555 kits include: IP67 hard case, NIST traceable certificate of calibration and
additional ruggedized crocodile clips
Display Graphical LCD, 128 x 64pixels
Insulation resistance 0.00 → 100.0 MΩ, 0.01MΩ, 0.1 MΩ
Protective earth resistance(10A)
0.00 → 20.00 Ω/0.01 Ω Test voltage /current 250 → 500 V (in 10V steps)>1 mA DC
Max. test current/voltage > 10 A / > 4 V AC Residual voltage measurementrange
0.0 → 400 V AC/DC
Protective earth resistance(0.2A)
0.00 → 4.00 Ω/0.01 Ω High voltage test voltage/current
1000V / 50mA AC
Test Current/Voltage > 0.2 A / > 4 V AC Trip current 5, 10, 25, 50mA (adjustable) Loop/Line Impedance 0.00 → 20.00 Ω/0.01 Ω Power Supply 230V +10%/-15% 50 Hz, max.
100 VA Test current 20 A (10ms) @ 230V Dimensions & weight 340 x 310 x 170 mm: 7kg
Supplied with: Test leads, carry case and comprehensive user
MIT520/2 additional features
instructions.
Stock no. Price per OM S$ S$ S$
700-7806S unit 1+ 3610·00
Pre-programmed tests: PI, DAR, SV(Step voltage),
Dielectric Discharge (DD) test for multilayer insulation, ideal for detecting cavities in generator &
motor armature windings
Selectable audible alarm points indicates when required insulation level is attained – saving test
time in production & repetitive testing applications.
Selectable breakdown or burn mode
Real time data output-RS232 and USB
32kB data storage
Download software using Megger Download Manager (supplied)
Variable test voltage and time intervals
Note: Please contact RS for calibration requirements
Earth Continuity Load Current 13A maximum Test Current ±200mA DC Test Duration 30s maximum user controlled Test Duration 60ms nominal Pass Value 3.5mA ± 0.2mA Class I
0.25mA ± 0.05mA Class II Pass Value 0.2Ω IEC Lead Test
Insulation Resistance Test Voltage 7V nominal Test Voltage 500Vdc Test Duration 2s nominal Test Current 1mA into 500kΩ 2mA short circuit Test Earth Continuity
Insulation ResistanceLive, Neutral Continuity and Polarity
Test Duration 2s nominal Power Socket Test
Pass Value 2 MΩ Input Voltage Range 230V ±10% - 15% AC Differential Leakage Voltage Indication Phase to Earth Voltage
Phase to Neutral VoltageNeutral Earth
Test Voltage 230V ± 10%
Accessories
Supplied with: 3m test lead set, USB & RS232 download leads (MIT520/2 only) and Download
Manager software (MIT520/2 only) user guide.
Test Voltages dc 250V, 500V, 1kV, 2.5kV, 5kV and 10kV (Fluke 1555 only)-0%, +10% at 1mA load current
Resistance measurement 200kΩ → 100 GΩ: ± 5%,(Fluke 1550)200kΩ → 200 GΩ: ± 5%,(Fluke 1555) 200GΩ → 1TΩ: ± 20% (Fluke 1550)200GΩ → 2TΩ: ± 20% (Fluke 1555)
Bargraph range 0 → 1 TΩ
Leakage current measurement 1 nA to 2 mA ±(5% + 2 nA)
Capacitance Measurement 0.01 μF to 15.00 μF ±(15% rdg + 0.03μF
Voltage input range 95-240 V ±10% rms 50/60 Hz and DC Capacitancemeasurement
10nF to 50μF (dependant onmeasurement voltage); ±5% ±5nF
Battery life 8 hours continuous testing at 5kV Voltage outputaccuracy (0°C to 30°C)
±4% ±10V of nominal test voltage at1GΩ load;±25V for test voltages less than 500V
Test voltages 50 to 1Kv in 10V steps1Kv to 5kV in 25V steps
Current measurementrange
±0.01nA to ±5mA ; ±5% ±0.2nA
Accuracy (23°C) ±5% to 1TΩ; ±20% to 10TΩ Display Analogue/Digital 3 digits Guard 2% error guarding 500kΩ leakage
with 100MΩ load Interference rejection 2mA rms @ 200VB and above
Display range Digital display 10kΩ to 15TΩ;Analogue display 100kΩ to 1TΩ
Timer range Counts up to 99 minutes from startof test
Short circuit/chargecurrent
3mA Dimensions 305 x 194 x 360 mm
Capacitor charge time ≤5 seconds per μF at 3mA Weight 7.1 kg Capacitor dischargetime
<120ms seconds per μF todischarge from 5000V to 50V
Stock no. Price per OM S$ S$ S$
717-3653S unit 1+ 947·00
Description Stock no. Price per OM S$ S$ S$
Barcode Scanner, USB 700-7803 unit 1+ 580·00
Keyboard, USB, UK 704-7390 unit 1+ 90·00
Description Stock no. Price per OM S$ S$ S$
MIT510 712-5761S unit 1+ 5012·00
MIT520 712-5765S unit 1+ 6394·00
2266
www.nguyenxuong.com
Cable Tracers/Fuse FindersCable Fault Locators
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Fluke 2042 Kit
Lexxi T810, Cable Fault Locator
Lexxi T810
MIT1020 10kV Insulation Tester10kV insulation resistance tester in a rugged IP65 case to
enable simple safety checks on insulation and also a range
of predictive tests for preventative maintenance. IEEE 43-
2000 recommends the use of 10kV for motor windings rated
above 12kV.,Safety features include automatic discharge of
capacitive energy, test inhibit if >50V detected at test leads
and timed start button to prevent inadvertent operation if
button is jammed etc.
Cable locating set comprising a transmitter and receiver in a hard
carrying case. The transmitter connects to the cable / metal pipe to
be traced and sends a carrier signal containing a user-selected
code. The non-contact receiver detects the signal and displays the
code. Additional transmitters are available to allow multiple cables
/ pipes to be traced and identified. Both live and dead circuits can
be located.
H.260, W.110D.75, Wt.750g
Automatic cable attenuation compensation simplifies use
Narrow pulses give high resolution trace image
Automatic default pvf, impedance and gain algorithm set by cable selection
Traces cable & metal water/heating pipes in walls and
underground
Locates fuses and assignment to circuits
Locates concealed sockets and distribution boxes
Locates interruptions and short-circuits in unshielded electrical
cables & underfloor heating
Tracing depth up to 2.5m dependant on material (concrete etc.)
Mains voltage location up to 0.4m
Large, high resolution display
Tactile push buttons
Wide operating temperature range for field use
10kV dc test voltage, 3mA short circuit current
Automatic IR test
35TΩ resistance range
Guard terminal for enhanced accuracy (guard test lead
supplied)
Ranges from 10m to 3000m
Automatic cable attenuation compensation simplifies use
Narrow pulses give high resolution trace image
Select one or more test leads to suit your application:
Transmitter LCD display for transmission level, transmitting code and external voltage
Receiver with LCD display of received signal level, code and live voltage indication
Torch lamp function
Battery powered with mains supply for power or battery recharge
Rugged polypropylene case
IP65 ingress protection (lid closed)
Operating temperature -20°C → +50°C
Digital/Analogue backlit display
Voltage, leakage current, capacitance, time constant display
Pre-programmed tests: PI, DAR, SV(Step voltage),
Dielectric Discharge (DD) test for multilayer insulation, ideal for detecting cavities in generator &
motor armature windings
Selectable audible alarm points indicates when required insulation level is attained – saving test
time in production & repetitive testing applications.
Selectable breakdown or burn mode
99 minute count up timer
Complies with EN61010-1 Cat IV 600V
Quick reference guide inside the lid
Real time data output-RS232 and USB
32kB data storage
Download software using Megger Download Manager (supplied)
Variable test voltage and time intervals
Automatic default pvf, impedance and gain algorithm set by cable selection
Large, high resolution display
Tactile push buttons
Wide operating temperature range for field
MIT1020 10kV Insulation Testers
L810/3/PWR - LV power cable see RS stock no. 315-8332
L810/3/75 - Coax CATV, 75Ω see RS stock no. 339-8287
L810/3/100 - telecoms and data comms 100Ω twisted pair cable, see RS stock no.
339-8300
L810/3/BNC - F-BNC & BNC to F outlet adaptor see RS stock no. 339-8322
Supplied with: carry bag, operating manual and batteries.
Supplied with: Carry Bag, operating manual and batteries.
Supplied with: 3m test lead set, USB & RS232 download leads and Download Manager software user
guide
Select the instrument T810, then select one or more test leads to suit your application.
Charging Rate for capacitive load 5 seconds per μF
Discharge rate for capacitive load 1.55 seconds per μF
Live circuit warning 30 V → 660V ac/dc 50/60Hz ±(15% + 2 V)
Power 12V Lead-acid rechargeable battery: internal mains powered charger
Dimensions & Weight 269 x 277 x 160mm : 3.7kg
Voltage input range 95-240 V ±10% rms 50/60 Hz and DC Capacitancemeasurement
10nF to 50μF (dependant onmeasurement voltage); ±5% ±5nF
Battery life 4 hours continuous testing at 10kV Voltage outputaccuracy (0°C →30°C)
+4% ±10V of nominal test voltage at1GΩ load;±25V for test voltages less than500V
Test voltages 50 → 1kV in 25V steps, 1kV → 10kVin 25V steps
Current measurementrange
±0.01nA → ±5mA ; ±5% ±0.2nA
Accuracy (23°C) ±5% → 1TΩ; ±20% → 20TΩ Display Analogue/Digital 3 digits Guard 2% error guarding 500kΩ leakage
with 100MΩ load Interference rejection 2mA rms @200V and above
Display range Digital display 10kΩ to 35TΩ;Analogue display 100kΩ to 1TΩ
Timer range Counts up to 99 minutes from startof test
Short circuit/chargecurrent
3mA Dimensions 305 x 194 x 360 mm
Capacitor charge time ≤5 seconds per μF at 3mA Weight 7.1 kg Capacitor dischargetime
≤250ms per μF to discharge from10000V → 50V
Pulse characteristics
Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impedance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250V a.c. rms 50/60Hz to the input.
For safety reasons, however, it should NOT be operated under these conditions. For safe useon cable carrying hazardous live voltages, the blocking filter test lead must be used.
Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes
Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen contrast,with automatic temperature compensation Units - meters or feet pvf adjustment
Power 6AA size LR6 batteries Operating temperature -20 to +55°C Dimensions 250 x 100 x 95 mm Weight 0.6 kg
Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen)
L810/3/PWR - LV power cable
L810/3/50- Coax LAN cable, cellular, TV & satellite antennae, 50Ω
L810/3/75 - Coax CATV, 75Ω
L810/3/100-telecoms and data comms twisted pair cable,100Ω
L810/3/BNC- F-BNC & BNC to F outlet adaptor
Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen) Pulse characteristics Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impendance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250VAC rms 50/60Hz to the
input. For safety reasons, however, it should NOT be operated under these conditions.For safe use on cable carrying hazardous live voltages, the blocking filter test leadmust be used.
Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen
contrast, with automatic temperature compensation Units - metres or feet pvfadjustment
Power 6AA size LR6 batteries Operating temperature -20°C to +55°C
Type Insulation Resistance Tester Safety EN 61010 safety rating CAT IV 1000 V, CAT III 1000 V Display Type LCD with analogue bargraph
Stock no. Price per OM S$ S$ S$
712-5774 unit 1+ 8095·00
Stock no. Price per OM S$ S$ S$
669-9552 unit 1+ 2250·00
Manu. Part No. Stock no. Price per OM S$ S$ S$
10/L810/3/50 339-8293 unit 1+ 73·50
Description Stock no. Price per OM S$ S$ S$
Fluke 1550 5kV Tester 705-1957S unit 1+ 5124·00
Fluke 1550 5 kV Tester Kit 705-1951S unit 1+ 5773·00
Fluke 1555 10kV Tester 705-1960Sa unit 1+ 6353·00
Fluke 1555 10 kV Tester Kit 705-1963S unit 1+ 7074·00
Accessories
Description Stock no. Price
per
OM S$ S$ S$
L810/3/PWR test lead for powercable
339-8287 unit 1+ 370·00
L810/3/75 test lead for 75Ωcoax
315-8332 unit 1+ 86·50
L810/3/100 test lead for 100Ω t/pair
339-8300 unit 1+ 86·50
L810/3/BNC-F BNC to F Adaptor 339-8322 unit 1+ 73·50
2267
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Meterman ECB50
Amprobe ECB50A
Elite Professional Fuse Finder KitMartindale FD650
Ideal 61-954 & 61-958 SureTest CableTracer Kits
61-958
The transmitter module generates a coded signal that is injected
into a powered AC line, and the receiver wand uses this signal to
The multi-purpose version of the popular FD550. Supplied in
a robust case complete with transmitter and receiver,
additional features include a 13A plug top lead for sockets
and fused test lead set with crocodile clips for junction boxes,
terminals and lighting circuits.
The ECB50 is offered in 100 to 250V configuration. The transmitter
reject noise and correctly identify the correct circuit breaker or fuse wire.
module generates a coded signal that is injected into a powered AC line. The receiver wand
uses this encoded signal to reject noise and correctly identify the right circuit breaker wire.
Supplied with: 13A plug in transmitter, Elite receiver &
instructions, rugged hard carry case, TL93 leads with
crocodile clips, 13A mains adaptor.
Includes 2042 receiver, 2042T transmitter, 4 test leads, 2 crocodile clips and 2 test probes
Three testers in one:-
Three testers in one:
61-954
Stock no. Price per OM S$ S$ S$
719-0908S unit 1+ 253·00
Note: Additional transmitters are available separately for extension or to distinguish between several
signals
Identify circuit breaker to electrical sockets
Trace AC cables in walls
Identify AC wires in a bundle
2 troubleshooting test tool kits for
finding circuit breakers and
hidden wire problems in electrical
wiring installations. These tracers
work on energized and de-
energized circuits. They identify
circuit breakers, find open and
shorts circuits and trace wires
behind walls and underground.
Identify circuit breaker to electrical socket:
Trace AC cables in walls
Sort AC wires in a bundle
Supplied with: Hard carry case, instructions, PP3 battery and 6xAA alkaline batteries
Identifies breakers & fuses
Pinpoints open & short circuits
in unshielded electrical cables
Traces wires behind walls
Locates cables, conduit or
metal pipe underground to a
depth of 4.5m
Additional features:
Additional features:-
Technical data
Transmitter: Dimensions 190 x 85 x 50 mm Display LCD with bargraph for external
voltage detection Weight approx. 450g
Voltage Receiver:
Measurement Range 12 to 400V (12V, 50V, 120V, 230V, 400V)Display 3½ digit LCD with bargraph for signalintensity
Frequency Range 0 to 60Hz Tracing Depth
Output signal 125kHz Cable Location Up to 2.5m wall/underground cables Max. Voltage up to 400Vac/dc Main voltage
detection Up to 0.4m
Measurementcategory
CAT III / 300V Power Supply 9V Battery (IEC 6LR61)
Pollution Degree 2 Dimensions 250 x 65 x 45mm Power Supply 6 x 1.5V Batteries (IEC LR6) Weight approx. 360g
TR-958 Transmitter
Microprocessor controlled
Coded transmission
Audible and visual indicators
Includes sensitivity adjustment
Cable tracing length to 150 meters (500 ft) nominal
Cable tracing depth to 40 cm (15 inches) nominall
Microprocessor controller
Coded transmission allows easy differentiation of transmitter signal
Audible and visual indicators
Includes sensitivity adjustment
Cable tracing depth to 400mm (15 inches) norminal
Receiver Tracing depth for fuse identification to 100mm (4 in) norminal
Standards: CAT lll 300V, Pollution Degree 2, Protection Class: IP20
Can be used on de-energized /energized circuits from 0-600V AC/DC
Live cable tracing without tripping RCDs
Indicates presence of AC/DC voltage
Meets EN61010 CAT III 1000V safety rating
Supplied with 3 AA alkaline batteries
Standards: EMC: EN 50081-1 and EN 50082-1, EN61010-1:2001
Description Stock no. Price per OM S$ S$ S$
2042 Cable Locator Kit 513-1799 unit 1+ 1357·00
2042T Additional Transmitter 513-1812 unit 1+ 662·00
Supplied with: Carry case & 9V battery
RC-954 receiver
Specifications Voltage range: 100 V to 250 V for ECB50-E
Power consumption: Approx 1 W
Transmitter Frequency range: 50 to 60 Hz for ECB50-E
Transmission frequency: Approx 8 kHz
Receiver Transmitter frequency: Approx 10 Hz
Tracing depth Approx 0 to 10 cm
for fuse identification: (4 in) depending on local conditions.
Tracing depth for Approx 0 to 40 cm
cable location: (15 in) depending on local conditions
Transmitter General Specifications
Operating temperature range: -10 °C to 40 °C max 80 % R.H.
Dimensions: 70 x 55 x 86 mm
Weight: Approx 65 g
Receiver General Specifications
Sensitivity setting Using On/Off control
Low battery indication 7.5 V
Switching fuse/cable Manually using Fuse-Line switch
Operating -10 °C to 40 °C
temperature range max 80 % R.H.
Dimensions: 22 x 162 x 34 mm
Weight: Approx 100 g
Power supply 9 V battery, IEC 6LR61, Alkaline only
Applicable directives EMC: EN 50081-1 and EN 50082-1 and standards
Transmitter: Low battery indication 7.5V Operating temperature range-10 to 40°C at max. 80% RH Switching fuse/cable manually using Fuse-Line
switch Overvoltage category CAT III 150 V Operating temperature range-10 to 40°C at max 80% RH Pollution degree 2, Protection Class: IP20 Overvoltage category CAT III 300 V Size and weight 70 x 55 x 86 mm, 65g Pollution degree 2, Protection Class: IP20 Receiver: Power Supply 9 V battery, IEC 6LR61, Alkaline
only Sensitivity setting Using On/Off control Size and weight 22 x 162 x 34 mm, 100g
Red LED display
Selectable receiver sensitivity modes: Search High, Search low, Trace mode & breaker mode
0-99 Numeric value display of signal strength & audible indication (pitch/tone) for easy to
understand tracing
Peak detecting bar graph display for detecting instantaneous changes in signal strength
Displays % of battery life remaining
Supplied with 4 AA alkaline batteries & connection lead set
Stock no. Price per OM S$ S$ S$
627-5755 unit 1+ 124·00
Stock no. Price per OM S$ S$ S$
543-879 unit 1+ 127·00
RC-958 ReceiverSuperbright OLED display
Rotating display for easy readout in all receiver orientations
Selectable receiver sensitivity modes: Search High, Search low, Trace mode & breaker mode
0-99 Numeric value display of signal strength & audible indication (pitch/tone) for easy to
understand tracing
Peak detecting bar graph display for detecting instantaneous changes in signal strength
Displays % of battery life remaining
Supplied with 4 AA alkaline batteries & connection lead set
Inductive Clamp with battery holder (IC-958)Connects to the TR-958 transmitter via 1.8m lead to induce a signal onto the circuit
25mm cable diameter clamp
Battery Pack holder with magnetic hanging strap (requires 6 type C cells not supplied)
61-958 currently not available
Contents
61-954 61-958
Transmitter TR-958 TR-958 Receiver RC-954 RC-958 Inductive clamp N/A IC-958 Carry case Yes Yes Test Lead Set Yes Yes
Transmitter Safety Complies with EN61010 Cat III, 1000V Operating frequency32kHzfixed amplitude, time modulated Receiver
Signal outputcurrent
200mA p-pmax into 50Ω Sensing Magnetic
Signal outputvoltage
30V nominal (2 Watts) Maximum Range 4.5m underground
Operating voltage 0- 600V ac/dc Signal response Numeric display and audible beep Battery Life 40 hours open circuit testing/25 hours
short circuit testing Battery life 20 hours
Indicators On/Off, Line Energized, Low Battery
Description Stock no. Price per OM S$ S$ S$
61-954 Cable Tracer Kit 613-1548 unit 1+ 1000·00
61-958 Cable Tracer Kit 613-1554 unit 1+ 1540·00
2268
www.nguyenxuong.com
BS1363A Mains Socket Testers
Cable, Metal And Stud Detectors
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
Cable and Metal DetectorMartindale TEK600
StudSensor i65 One Step
Wallscanner D-tect 150
Intellisensor� Stud Sensor
E-Ze Check Xtra MartindaleEZ150
Classic Check Plug MartindaleCP501
MT 6 Electronic Metal Locator
MultiScanner i700 One Step
MultiScanner i500 Zircon
Zircon
Zircon
Zircon
Scan through most non-metallic construction material including solid concrete,
tiles and marble (Not Wood or PVC pipes). A large LCD display pinpoints the
location of metallic targets to the nearest 2.54cm (1in.), and depth of the nearest
1.27cm (1/2in.).
A fast and easy way to test 13A sockets to BS 1363. When plugged
StudSensorTM i65 OneStep� quickly and easily locates studs behind non
metallic walls, floors and ceilings.
Patented CenterVision� technology finds the centre of studs in a single pass.
LCD display screen indicates direction, edge, and centre of studs
Signal strength indicator distinguishes between shallow and deep targets.
Find the centre of wood or metal studs or joists up to 38 mm (1-1/2 in.) deep
WireWarning� Alert provides continuous detection of unshielded energised
electrical conductors between 90 to 250V AC to a typical depth of 50mm (2
inches) for safety
ACT� (Auto Correcting Technology) corrects common user errors
automatically, such as when scanning begins over a stud.
Patented SpotLite� Pointing System shines a bright beam of light over target
centre
Rapid detection SCAN and precision LOCATE modes
Patented CenterVision� technology locates the centre and edges of wood or
metal studs behind non metallic walls, floors, or ceilings in one pass
Ideal detection tool to help to install cabinets, add electrical outlets, mount flat-
panel televisions on the wall, and other remodelling projects.
ACT�(Auto Correcting Technology) corrects common user errors
automatically, such as when scanning begins over a stud.
Backlit LCD screen with easy-to-understand on-screen graphics and audio
signal indicate target
The unique floating head design keeps the scanning head flat on rough surfaces
even if the handle is rocked or tilted.
Dual-sensitivity scanning—Normal mode up to 19mm (3⁄4 in.) or DeepScan� up
to 38mm (1 1⁄2 in.)
Finds copper pipes and other non ferrous metal up to 38mm (1 1⁄2 in.) deep
Finds rebar (ferrous metal) in concrete up to 76mm (3 inches) deep
Metal Detection Depth 150 mm Cable Detection Depth 150 mmStud Detection Depth 150 mm
Patented technology locates the centre and edges of wood or metal studs behind
non metallic walls, floors, or ceilings
CenterVision� Technology finds the stud centre in one pass
Backlit LCD screen with easy-to-understand on-screen graphics and audio signal
indicate target
Dual-sensitivity scanning—Normal mode up to 19mm ( 3/4 in.) or DeepScan� up
to 38mm (1 1/2 in.)
Finds copper pipes and other non ferrous metal up to 38mm (1 1/2 in.) deep
Finds rebar (ferrous metal) in concrete up to 76mm (3 inches) deep
Turn off wood and metal-scan to trace unshielded energised electrical
conductors, even in plastic conduit
Patented SpotLite� Pointing System shines a bright beam of light over target
Locates the edges of studs or joists through drywall and other
common wall materials to a maximum depth of 3/4" (19mm)
Audio and visual indication of stud edge detection
Automatic calibration switch
Durable ABS case
Automatic shut-off for longer battery life
Pocket size for easy storage
± 1/8" (3mm) wood stud centre detection accuracy
With Non-Trip Loop Impedance Check
Finds metal pipes and grids/bars, conduit or metal studs/joists up to 15cm (6in.)
deep
Pinpoints the location and depth of metal rebar and pipes
Readings in inches and centimetres
Automatic differentiation between steel and copper pipe (or any magnetic vs
non-magnetic metal)
Dual display LCD
One touch operation
Requires 9V PP3 battery (stock no. 394-9059)
The only safe solution for socket testing, as it varifies that the earth is
connected and indicates the quality of the earth connection. The T-Safe�
technology gives earth loop impedance checking without tripping 30mA
rated RCDs
13A mains socket tester
3 red/green LEDs indicate 6 loop impedance ranges (±10%): 0 - 1.7Ω, 1.7 -
5Ω; 5 - 10Ω; 10 - 100Ω; 100 - 200Ω; 200 - 500Ω
3 red/green LEDs indicates wiring good plus wiring fault conditions: P-N
reverse, P-E reverse, P fault, N open, E open
±1/4" (6mm) metal stud centre detection accuracy
Batteries are not included
Pinpoint accuracy provided by automatic sensitivity and conical sensor
housing
Detects even through damp plaster or foil backed plaster board
Compensates against extraneous influences such as metal-work in close
proximity or stray electromagnetic fields
Headphone socket provided for use in high noise environments
Requires 1 x PP3 9V battery (stock No. 394-9059)
centre
Continuous AC detection of unshielded energised electrical conductors between 90 to 250V to a
typical depth of 50mm (2 inches) for safety
Stock no. Price per OM S$ S$ S$
687-6162a unit 1+ 1244·00
Requires one 9V PP3 battery (typical stock no. 394-9059) not supplied
into a live socket, three neons lit up indicate correct wiring, whilst
one or more neons failing to light indicate wiring errors.
Select AC-SCAN to locate & trace unshielded energised electrical conductors, even in plastic
conduit
Patented SpotLite� Pointing System shines a bright beam of light over target centre
Integrated, erasable marker allows for one-handed operation.
Continuous AC detection of unshielded energised electrical conductors between 90 to 250V to a
typical depth of 50mm (2 inches) for safety
Requires one 9V PP3 battery (typical stock no. 394-9059) not supplied
Also indicates undervoltage (<195V) and overvoltage (>270V) conditions
Overvoltage Category: CAT II, 300 V
Ideal for testing 13A sockets
Three neons show wiring status
Flame retardant ABS casing
Metal Detection Depth 150 mm Width (mm) 109 Automatic Calibration Yes Depth (mm) 63 Height (mm) 251 Weight 286 g
Manu. Part No. Stock no. Price per OM S$ S$ S$
77-110 516-9429 unit 1+ 24·80
Metal Detection Depth 76 mm Cable Detection Depth 50 mmStud Detection Depth 38 mm Live ac Conductor Indication Yes
Metal Detection Depth 38 mm Cable Detection Depth 50 mmStud Detection Depth 38 mm Live ac Conductor Indication Yes
Supplied with: full instructions.
Metal Detection Depth 38 mm Stud Detection Depth 38 mmCable Detection Depth 50 mm
Stock no. Price per OM S$ S$ S$
418-369 unit 1+ 107·50
Voltage 240 V ac Earth Loop Impedance Test No Wiring Checked Yes
Stock no. Price per OM S$ S$ S$
418-363 unit 1+ 76·00
Stock no. Price per OM S$ S$ S$
418-379 unit 1+ 154·00
Twin and Earth cable detection depth 1.0 - 2.5 mm2
4.0 - 10 mm2
16 mm2
12 mm typ.25 mm typ.25 mm
Telephone & computer cable detection depth To a depth of 16 mm or better Operating temperature -5 °C → +40 °C Dimensions 50 x 64 x 30 mm Weight 190 g
Note: High sensitivity RCDs or excessive earth leakage currents may cause inadvertent tripping of the
circuit. Always check prior to use where loss of supply may be hazardous or unacceptable.
This unit is an indicator only and is not designed to provide readings for completing certificates
Stock no. Price per OM S$ S$ S$
418-353 unit 1+ 380·00
Stock no. Price per OM S$ S$ S$
255-676 unit 1+ 187·00
Voltage 230 V ac Earth Loop Impedance Test Yes Wiring Checked Yes Audible Tone No
Stock no. Price per OM S$ S$ S$
719-0885S unit 1+ 37·70
Stock no. Price per OM S$ S$ S$
719-0901S unit 1+ 154·00
2269
www.nguyenxuong.com
Aus/NZ Socket Testers
Phase Rotation Testers
Voltage Level Indicators
BS4343 Mains Socket Testers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
SOK 40 (2P & E)
Safety Plugs
Fluke 9040
Fluke 9062
Phase Rotation & ContinuityIndicator Martindale PC15250
3-phase industrial check plugwith Martindale phase rotationPC101
A range of voltage testers each available in versions suitable for electronic or electrical applications.
Buzz-IT Check Plug with SounderMartindale BZ101
16A Industrial Check PlugsMartindale CP201 & CP301
SOK 36
16A BS 4343 3 pin (2P+E) socket tester for testing 240V systems.
Manufactured from clear impact resistant PVC, the RS Australian and
New Zealand plug-in mains socket tester is designed to ensure
personal and equipment safety.
Motor rotation and rotary field indicator with contact-free detection
Indication of the three phases via LCD
Indication of the phase rotation direction via LCD
Swift determination of the phase sequence in three-phase networks
Voltage and frequency range suitable for industrial systems
LC-display with good visibility in bright areas (i.e. outdoor)
Fused test probes (500mA 1000V fast acting)
Logical green for go indication shows good wiring status - 3 green
LEDs indicate good wiring status
Detects 18 faulty wiring condition
Continuous audible tone indicates correct wiring
Strong warbling tone indicates incorrect wiring
Audible fuse finding facility
This indicator will prove continuity, or identify fault condition, of all
Socket TesterThe green neon will light if the socket tested is wired correctly. The
For 3-phase socket outlets, this indicator will instantly verify connection,
or identify non-connection, of all three lines and shows the sequence of
phase rotation. To ensure the correct and safe operation of 3-phase plant
with motors turning in the expected direction, it is fitted with a red 16 A, 4-
pin, 3-phase and earth BS4343 plug.
As with the Martindale classic check plug, this is a fast and easy way
to test 13A sockets. Also incorporates audible indication of correct
wiring for hard-to-locate sockets and can be used as a basic fuse
finder.
Rotary field Indicator – indication of the three phases via LED
Motor rotation Indicator - display of motor rotation direction
Contact free determination of the rotation direction of running motors
Swift determination of the rotary field as for conventional rotary field indicators
Magnetic field detection to detect AC solenoid valve
Contact-free determination of rotation direction of running motors.
Ideal if motor shafts are not visible or difficult to access. (i.e. circulating pumps)
Voltage free and safe detection of three phase motor connectors .
Indicates the motor rotation before starting the motor
Fused test probes are 500mA 1000V fast acting
three lines and shows the sequence of phase rotation. It’s a fast, effective
method of identifying worn or unmarked cables and ensures 3-phase outlets and
machines are wired correctly.The retractable GS38 probe shields give a choice of
long, exposed tips for inaccessible contacts or safer, shorter lengths for
increased safety.
Fast and safe indication of socket wiring
Three neons show wiring status
Incorporates audible indication of correct wiring
Fuse and trip finding, located when buzzer stops
Flame retardant ABS housing
The simplest, safest and most efficient
method of checking 16A 2P+E BS4343
sockets
Intended for use on industrial 240V
sockets whilst the 110V check plug will
check centre tapped 110V supplies
Both the 110V and the 240V Check
Plug are fitted with a standard BS4343
orange neon will light if there is a fault, i.e. missing earth or reversed polarity.
Contact RS for calibration requirements
With Non-Trip Earth Loop Impedance, Polarity
& RCD check
Indications include:
Supplied with: key/belt ring.
Voltage 240 V ac Earth Loop Impedance Test No Wiring Checked Yes Audible Tone Yes
16A plug
Fault conditions displayed on three neons on the 240V checker and on three LEDs on the 110V unit
Both Check Plugs list fault conditions and their associated indications on the face of the unit
Supplied with: 4-pin 16 A plug, instructions
Live - earth reverse
Live - neutral reverse
Faulty, neutral, earth and live
Missing live
Weight 200 g
Operational check of 30mA RCDs
Supplied with: 3 fused test probes, 3 crocodile clips, instruction
manual.
Overvoltage Cat. CAT III 600V Voltage Range 100 to 600 VFrequency Range 40 to 60Hz
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
719-0891S unit 1+ 48·90
Tests for total supply system polarity safety
Bright LED’s indicators with logical Green for Go LED Indication
Detects good plus 17 wiring fault conditions
Clear indication of where the actual fault is - Live, Earth or
Neutral
Continuous or strong warbling tone gives positive quick
indication of good or faulty wiring
Colour LED read out shows earth loop impedance result as
Good, Check or Urgent Check; Good when less than 1.8Ω
Built-in self check
Approvals: Australian Standards Approval number CS900020.
Supplied with: One fused crocodile clip, two fused prods with retractable GS38
shrouds, instructions
Voltage Range 40 to 700 V Measurementcategory
CAT III, 600 V / CAT IV,300V
CurrentConsumption
approx. 1 mA @ 700 V Safety Complyingwith
IEC61010 / EN61010,IEC61557-7 / EN61557-7
Frequency Range 15 to 400 Hz
SOK ADP40 Converts S0K40/16 into a 32A tester
16A socket to 32A plug
Stock no. Price per OM S$ S$ S$
254-308S unit 1+ 165·00
Note: High sensitivity RCDs or excessive earth leakage currents may
cause inadvertent tripping of the circuit during loop check. Always
Stock no. Price per OM S$ S$ S$
467-4964 unit 1+ 80·00
Stock no. Price per OM S$ S$ S$
424-585S unit 1+ 220·00
Stock no. Price per OM S$ S$ S$
780-059 unit 1+ 35·90
Pins 3 Wiring Checked Yes Audible Tone No
Description Stock no. Price per OM S$ S$ S$
Fluke 9040 513-1828S unit 1+ 467·00
1000V 500 mA Fuse 388-4132 unit 3+ 5·30
check prior to use where loss of supply may be hazardous or unacceptable.
This unit is an indicator only and is not designed to provide readings for completing certificates
Supplied with: 3 Fused test probes, 3 pc Crocodile clips,3 pc Test leads 9 V PP3 battery, Protective
Holster and Instruction manual
Description Stock no. Price per OM S$ S$ S$
240V - Blue plug CP201 253-535S unit 1+ 53·50
110V - Yellow plug CP301 253-541S unit 1+ 72·00
Voltage 230V
Wiring Checked Yes
Earth Loop Impedance Test Yes
30mA RCD test Yes
Polarity Test Yes
Audible Tone Yes
Voltage Range 1400 Vac Measurement category CAT III / 300 V Phase Display 120 - 440 Vac Protection Degree IP 40 Frequency range 2400 Hz Safety Complying with IEC61010 / EN61010, IEC61557-7 / EN61557-7 Test Currents < 3.5 mA
Description Stock no. Price per OM S$ S$ S$
Fluke 9062 513-1834S unit 1+ 340·00
1000V 500 mA Fuse 388-4132 unit 3+ 5·30
Description Stock no. Price per OM S$ S$ S$
SOK 36 704-7747a unit 1+ 126·00
2270
www.nguyenxuong.com
Dig. Readout Volt Level Indicator
Mains Voltage Indicators- Contact
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
Fluke T100 Series Voltage and ContinuityTesters
Combicheck 1.3 6-690V AC/DC
240V Proving Unit for Neon VoltageIndicators
Digicheck 3.2
Fluke T120 & T140 LCD Display,12 to 690VAC/DC
Filament Test Lamps Drummond MTL7and MTL9C
Safety Voltage IndicatorMartindale VI13700
Mastercheck 3.2 6-400V AC/DC
Voltage testers with or without resistance measurement facility
An essential safety aid that is widely specified by training
LED voltage Indication
Illuminated test probe
Continuity testing with audible buzzer for continuity and voltage
Phase sequence testing
>90Vac Single Phase Test
Line powered LED indicates 50V-120Vac/dc even without batteries
Supplied with 2 x AAA batteries 591-657 (upto 1500 hours operation)
IP50 enclosure
Safety approved in accordance to EN61243-3 and VDE 0682 Part 401
A handheld, battery powered proving unit able to provide a nominal 240Vdc,
2mA source to prove the integrity of neon type test voltage indicators
For safety, voltage indicators should be checked for correct operation from
this known voltage source before and after every use
The unit is housed in a compact ABS plastic case and fitted with a belt clip for
convenience
An LED is used to indicate battery condition
Digi check 3.2 with AC/DC range and continuity test on a 2000 count LCD
display, with back light.
2-pole tester with LED
12 to 690V a.c./d.c voltage indication range
Diode/ Continuity test with visual and acoustical indication
Integrated single pole test for phase detection
Rotary field indication
IP65-water-jet and dust-tight protection for outdoor use
Electrical torch function for working in dark environments
Automatic, internal load for tripping out 30mA RCD’s
Quick response time (<0.1s) for fast voltage tests
Battery test function
Probe-tip protection permanently attached to lead
Complies with GS38 with regard to probe tip construction (less than 2mm of exposed
metal tip)
Fully operational voltage indication even when batteries are discharged or when no
Two filament test lamps giving safe indication of voltages
between 150V and 500Vac/dc. Their robust design meets the
recommendations of the Health and Safety Executive in
their guidance notes on electrician’s test lamps (GS38)
LED voltage Indication
Line powered LED indicates 50 to 120Vac/dc even without batteries
2 pole tester with LED and 3½ digit LCD 1999 count display
12 to 690V ac/dc voltage indication range
Diode/continuity test with visual and acoustic indication
Integrated single pole test for phase detection
Rotary field indication
IP65 protection for outdoor use
Integral torch
Automatic, internal load for tripping out 30mA RCDs
Quick response time (<0.1s) for fast voltage tests
Battery test function
Probe-tip protection permanently attached to lead
Stock no. Price per OM S$ S$ S$
481-2116 unit 1+ 83·50
0 to 100Hz (ac >2Hz) frequency range
IP50 enclosure
Safety approved in accordance to EN61243-3 & VDE 0682 Part 401
Supplied with 2 x AAA batteries (upto 1500 hours operation), see RS Stock
no. 591-657)
Automatic range selection
Illuminated measuring probes
Audible buzzer on continuity test
Display hold function
Polarity (+/-) check
Single pole phase testing
Transistor check
Battery Low indicator
Battery and function test
batteries are fitted
Complies with EN61243-3 and EN61010-1
Input protection to EN61010-1 CAT IV 600V
Note: This product will only work with test voltage indicators that have an input
impedance of greater than 120kΩ.
organisations, utilities and large contractors. This GS38 compliant voltage indicator
rapidly and safely checks if a circuit is live, its voltage range and AC and DC voltages
from 50V to 600V.
Tough, moulded case
Double insulated leads
Probe tip contains finger guard and lockable, retractable prod sheath
Probe incorporates a 500mA HRC fuse
Stock no. Price per OM S$ S$ S$
242-4111S unit 1+ 146·50
Automatic on/off to save battery life
Norm: VDE 0682 part 401 / EN/IEC 61234-3
Electrical version complies to HSE GS38 recommendation with less
Complies with GS38 with regard to probe tip construction (less than 2mm of exposed metal tip)
Fully operational voltage indication even when batteries are discharged or when no batteries are
fitted
Complies with EN61243-3 and EN61010-1
Input protection to EN61010-1 CAT IV 600V
Resistance measurement up to 1999Ω (T140 only)
Backlight (T140 only)
Contact RS for calibration requirements
Input Current Is <2.5mA at 690V Input Impedance ≥300 kΩVoltage Surge Proof 6kV Continuity Check Yes Voltage Range 6 → 690 Vac/Vdc Frequency Range 0 → 100 Display Type LED
than 4mm of exposed metal tip
Standard version has probes with 15mm exposed tips
Powered by 2 x AAA batteries (not supplied)
Surge proof to 6kV
Contact RS for calibration requirements
Input current Is <2.5mA at 400V Input Impedance 265 kΩVoltage surge proof 4kV Continuity Check Yes Voltage Range 6 → 400 Vac/dc Resistance RangesDisplay Type LED Frequency Range 0 → 100 Hz
Supplied with: Instruction leaflet & batteries.
Stock no. Price per OM S$ S$ S$
621-1155S unit 1+ 116·00
Supplied with: Instruction leaflet & batteries
Supplied with: Instruction manual.
Stock no. Price per OM S$ S$ S$
410-0104S unit 1+ 66·50
Display 12, 24, 50, 120, 230, 400, 690V LED bargraph Continuity range 0 → 400kΩVoltage range accuracy ±(3% rdg +3 digit) Power supply 2 x AAA (IEC LR03) supplied Continuity/ Diode test Optical (LED) / acoustical Operating Frequency 0 - 400 Hz
Supplied with: Operating instructions.
Description Stock no. Price per OM S$ S$ S$
T100 502-5694S unit 1+ 564·00
T100, Aus version 516-6290 unit 1+ 110·50
Voltage Range 0 to 600 V Continuity Check No Display Type LED
Voltage Range 5 to 690 Vac/dc Continuity Range 0 to 500 Input Impedance >600 kΩ Display Type LCD
Display 3½ digit LCD , 1999 count and 12, 24, 50, 120, 230, 400, 690V LED bargraph Voltage range accuracy ±(3% rdg +3 digit) Operating frequency 0 to 400Hz Resistance Measurement Up to 1999Ω (T140 only) Continuity/ Diode test Optical (LED) /acoustic Continuity range 0 to 400kΩPower supply 2 x AAA (IEC LR03) supplied
Accessories
Stock no. Price per OM S$ S$ S$
719-0882S unit 1+ 118·00
Stock no. Price per OM S$ S$ S$
493-4200 unit 1+ 230·00
Description Stock no. Price per OM S$ S$ S$
T120 502-5701S unit 1+ 172·00
T120 516-6307 unit 1+ 195·50
T140 721-5385S unit 1+ 240·00
T140 516-6313 unit 1+ 224·00
C33 Carry Case 502-5723 unit 1+ 49·90
Description Stock no. Price per OM S$ S$ S$
C33 Carry Case 502-5723 unit 1+ 49·90
TP38 Slender Probes 384-8265 unit 1+ 28·80
AC285 Large Alligator Clips 451-1431 unit 1+ 36·40
AC220 Alligator Clips 449-9915 unit 1+ 61·40
2271
www.nguyenxuong.com
Voltsticks- Non Contact
Mains Test Screwdrivers
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
Mains Test Screwdriver
VDE Insulated
Volt-Stick AC Indicator
Volt-Stick AC Indicator, Intrinsically-Safe
Volt-Stick PRO Selective AC Indicator
Volt-Stick SOUND AC Indicator with audible alarm
EPF 30 Professional Easy PhaseFinder 50-400Vac 50/60Hz
Proving Unit Martindale PD690
The Volt Stick SOUND is a pen style non contact AC voltage
indicator for safely checking the presence of an AC voltage in
cables, wall sockets, fuses junction boxes etc. No current flow
A single pole voltage detector that does not require the user
to operate touch pads or any direct contact device. The EPF30
overcomes the limitation of non contact phase-live detectors
whereby under OPEN CIRCUIT parallel conductor conditions
conventional testers may give false indication of a live
The Volt Stick PRO, is a pen style non contact AC voltage
indicator for safely checking the presence of an AC voltage in
cables, junction boxes etc. The patented forked tip design has
unsurpassed selectivity. This is because the maximum
sensitivity is between the two prongs of the fork. Outside the
is needed for correct operation.
Ingenious pocket devices for determining the presence of
50Hz AC voltages. They are battery powered pen style units
with nylon tips that glow red when a voltage is detected.
There is no necessity for contact or for current to be flowing
in order to activate the unit. Ideal for finding breaks in power
cables, checking plug wiring, checking fuses, distinguishing
between live and neutral wires, determining live cables in
junction boxes, finding faulty switches, locating the faulty
lamp in a series, and many more.
Battery powered proving unit, essential for safe use of voltage
indicators and test lamps.
High quality VDE mains testing screwdriver manufactured to
DIN57860 Part 6 and VDE0680/6, suitable for use on
150V-250V. Screwdriver incorporates a neon indicator and is
sealed to prevent tampering. Blade tips are hardened and
blackened chrome-vanadium steel.
conductor.
Overall Length 146 mmBlade Dimensions 60 x 3 mm
fork the sensitivity is low, so external interference fields have small effect.
230V: range 220 to 400Vac (with respect to ground
potential). The sensitivity is optimised for detecting 230V
50Hz mains voltages.
Approved for use in hazardous areas, the
intrinsically safe Volt stick has all the features of
the standard 230V version with voltage
measuring range 230 to 1000V 50Hz (with
respect to ground potential).,Applications for
the volt stick include finding breaks in power
cables, checking plug wiring, checking fuses,
Test voltage indicators with ranges above 240V
690V (nominal) @ 0.5mA high output voltage source
Designed for use with Drummond and other similar lower resistance test
lamps, having sufficient output to cause illumination
Neon indicates battery condition
Single probe operation, allows for non-contact voltage tester proving
(access 5mm)
Operates test voltage indicators that have greater than 4kΩ internal
resistance
6 x AA batteries (required, see stock no. 591-225), maintain output
voltage for extended testing.
143 x 83 x 50mm, (H x W x D) Wt. 300g
Tip glows red and the audible sounder activates when a voltage is detected.
Locates breaks in cables
Detects blown fuses inside plugs or fuse holders
Distinguish between live and neutral wires in both single and three-phase supplies
Identifies voltage-carrying cables in junction boxes
Identifies faulty in-line switches
Locates faulty lamps in series connections
Complies with IEC 61010-1 CAT III 1000V
Mains tester/screwdrivers with internal neon and
series resistor to enable use on 220-250Vac mains.
Clear plastic moulding with extension over chrome-
vanadium screwdriver shaft. Smaller version is fitted
with metal pocket clip. Conductive plastic finger
Powerful red light in the tip glows when a voltage is detected
High selectivity reduces the risk of spurious indications for better indication of live cables in
crowded cable runs
Slide in tip adapter is supplied to reduce the selectivity where larger cables and fuses need to be
checked
Live cables can easily be detected in equipment cabinets, fuse boxes etc
Extremely safe when measuring in junction boxes
Fully insulated for safe use
Supplied with clip in shunt for use as conventional low selectivity indicator
Complies with IEC 61010-1 CAT III 1000V
Stock no. Price per OM S$ S$ S$
719-0894S unit 1+ 232·00
Stock no. Price per OM S$ S$ S$
828-022 unit 1+ 10·50
contact.
True phase locator scanning technology determines the strongest true voltage and eliminates false
signal indication
Can identify the true live phase conductor amongst a bundle of open circuit conductors
Bright LEDs plus continuous audible tone gives clear indication from dim to bright conditions
50 to 400Vac 50/60Hz operating range
Rugged construction with finger guard configuration for safe operation
Drop proof from 2 metres
Built in self test to indicate correct operation
Powered by PP3 battery (not supplied, see stock no. 394-9059)
3 minute auto power offdistinguishing between live and neutral wires, determining live cables in junction boxes, finding faulty
switches, locating the faulty lamp in a series, and many more. This handy instrument will prove
invaluable in saving time when troubleshooting.
110V: range 90 to 400Vac (with respect to ground potential). The sensitivity is optimised for detecting
110V 50Hz voltages as found in factory and other industrial applications.
Supplied with: 2 AAA batteries & instructions
Description Overall Length (mm) Blade Dimensions (mm) Stock no.
Small Test Screwdriver 134 60 x 3 544-853
Large Test Screwdriver 196 108 x 3.5 549-448
Supplied with: Nylon carry case with belt loop and instructions.
Note: Will NOT detect cables behind buried plaster, buried trunking etc. and will not detect output
from safety isolation transformers with earthed secondary centre tap. The unit should be checked for
correct operation using a known voltage before use.
Supplied with: 2 x AAA batteries and instructions.
Group & Category: II 2 G EEx ib IIC T4
Stock no. Price per OM S$ S$ S$
719-3017S unit 1+ 84·00
Description Stock no. Price per OM S$ S$ S$
Small Test Screwdriver 544-853 unit 1+ 1·50
Large Test Screwdriver 549-448 unit 1+ 1·90
110V model 230V model
Power supply 2 x 1.5V AAA alkaline batteries (supplied)
Sensitivity (50Hz) 230 VAC Operating temp: -10 °C → +50 °C Power supply: 2 x AAA (LR03) batteries Dimensions & weight 146 mm x Ø max 22mm : 40g
Sensitivity (50Hz∼) illuminate at 4mm from wire 90V 220V Temperature -20 → +50 °C Response Instantaneous
Forked tip cable capacity 4.5mm diameter Operating temperature -20 °C → +50 °C Operating frequency 50Hz Over-voltage CAT III 1000V Power Two AAA (LR03) batteries (supplied)
Power supply 2 x 1.5V AAA alkaline batteries (supplied) Sensitivity (50Hz∼) illuminate at 4mm from wire 220V Operating temperature -20 → +50 °C Response instantaneous
Description Stock no. Price per OM S$ S$ S$
Volt-Stick Indicator 230V 214-467 unit 1+ 42·90
Volt-Stick Indicator 110V 238-3571 unit 1+ 42·90
Stock no. Price per OM S$ S$ S$
167-645 unit 1+ 39·30
Voltage Range (V(ac)) Stock no. Price per OM S$ S$ S$
110 – 1000 166-816 unit 1+ 58·50
230 – 1000 166-838 unit 1+ 58·50
Description Stock no. Price
per
OM S$ S$ S$
Intrinsically Safe Volt-Stick(ATEX)
457-8327 unit 1+ 98·00
Intrinsically Safe Volt-Stick(IECex)
166-822 unit 1+ 72·00
2272
www.nguyenxuong.com
Automotive Voltage Indicators
Magnet Sticks Non-Contact
Cable Tracing
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Car Voltage Tester
Non-Contact Voltage andMagnetic Indicator MartindaleTEK200
Unitest MAGNO-VOLTfix
Magnetic Field Indicator / Solenoid Tester
Intrinsically-Safe Magnetic Field Indicator
PTS100/200 - Pair Tracing Kit
LVD2 Volt Light
Non-contact AC voltage detector and LEDflashlight
Fluke 1AC Voltage Detector
Tester for automobile electric and electronic circuits. Its low
power consumption of 1.5mA is suitable for locating faults
in electronic components where conventional lamp testers
may cause damage. It has a crocodile clip on one end, and a
tester with LED display and probe tip. The bright LED display
indicates voltage and polarity. Particularly suitable for
trouble shooting in wiring harnesses with catch hook to
reach any wire and a pricking needle to probe through the
insulation.
Fluke VoltAlert� - Suitable for non contact detection of AC
voltage from 90 to 1000Vac.
The next generation VoltAlert� AC non-contact voltage
testers from Fluke are easy to use — just touch the tip to a
The tip of the Magnet Stick lights up when in the presence of
a magnetic field. It responds to all kinds of magnetic fields
from alternating current to direct current and permanent
strong magnets.,A small test magnet is housed in the cap of
the Magnet Stick to check that it is working correctly.
Contact-free, optic and acoustic detection of AC voltages
Magnetic field detection
Precise detection of line interruptions in open installed
cables
Compact, pen style construction
H.140 W.24 D.20mm Wt. 50g
Bright white flashlight illuminates working area
Blue indicator means you’re close
Red indicator means you’re at the source
Detects voltage from 40Vac to 300Vac upwards
Comes with versatile clip to secure light to a pocket, hat or even a
panel door
Operating temperature 0 °C → +50 °C
Ultra bright white LED with 100000 hour bulb life
AAA battery included"
Non-contact AC voltage detector and LED flashlight
combined into one easy to use pen-style design. The LVD2
is a CAT IV 600 V rated non-contact detector that is suitable
for commercial and industrial applications. The LVD2
includes dual sensitivity indication, showing blue when 1”
to 5” (2.54 cm to 12.7 cm) from the source and turning red
when at the source.
The PTS Pair Tracing System comprises the PTS 200 Tone
Generator and the PTS 100 Probe in a woven polyester
carrying pouch. The System is designed to provide an easy
to use and cost effective means of tracing wire pairs
A non-contact voltage indicator with the additional ability to
detect magnetic fields.,Suitable for indicating the operation
of solenoid valves in pneumatic and hydraulic control
equipment, and testing relays or solenoids in a wide range
of vehicle and machine controls.
Input voltage 3-48Vac/dc Voltage display 2 LEDs
Standards: CAT IV 600 V
Approved for use in hazardous areas
The tip of the intrinsically safe magnet stick
lights up in the presence of a magnetic field
Responds to all kinds of magnetic field from
alternating current and direct current and
permanent strong magnets
Fast, Accurate Wire Identification
Sends Tone to Identify Wires
Polarity Indication
Continuity Test
Adjustable Volume Control
Easy to Operate
2-Line Modular Test Lead
Note: This unit uses a magnetic read switch sensor. For applications requiring more sensitivity we
recommend stock No. 254-099 which uses a Hall Effect sensor.
terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s
voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test
for energized circuits in the workplace or at home.
Display 2 LEDs Safety IEC 1010, EN 61010 Voltage Range 50 to 600Vac Overvoltage Cat. CAT III/600V Frequency Range 50 to 500Hz Pollution Degree 2Magnetic Sensitivity >25mT Power Supply 2 x AAA (IEC LR03) supplied
Stock no. Price per OM S$ S$ S$
225-3335 unit 1+ 32·40
Avoids the need for a separate proving unit
Tests relays, contactors and solenoids without
Stock no. Price per OM S$ S$ S$
493-3241 unit 1+ 43·40
Supplied with: AAA battery
Supplied with: Batteries fitted and an instruction leaflet.
Stock no. Price per OM S$ S$ S$
374-1849 unit 1+ 122·50
Supplied with: 2 x AAA alkaline batteries (stock No. 591-657) and integral test magnet.
Rugged Industrial design
Water Resistant
disconnecting them from circuit
Senses AC voltages from 100 to 600V by detecting the electrical field
Determines and displays polarity of magnetic fields
Self test facility ensures correct functioning
The self test circuit transmits a 50 Hz signal to the voltage or magnetic sensor to fully test the
integrity of the internal circuitry
Powered by PP3 battery (stock No. 394-9059)
Tip glows red when a voltage is detected
Pocket sized
Batteries included
Description Stock no. Price per OM
Fluke 1AC Voltage Detector 462-8545 unit 1+ 48·00
Fluke 1AC-II Voltage Detector 255-073 unit 1+ 48·30
PTS 200 Tone Generator:
Voltage Range 100V to 600Vac 3 mm at 110Vac 50Hz Voltage SensitivityDistance from a flat PVC 1 mm<sup>2</
sup>
twin and earth cable suspended in freespace:
23 mm at 240Vac 50Hz
Voltage IndicationRed LED and audible tone (3 kHz) in thepresence of an AC voltageGreen LED internal battery condition
Green LED south pole
Frequency Range 50Hz to 50kHz (voltage) Frequency Range 0 to 50kHz (magnetic) MagneticSensitivity
±10 mT Operating Temp. -5 → +40 °C
MagneticIndication
Red LED north pole Case Material ABS
Group & Category: II 2 G EEx ib IIC T4
Stock no. Price per OM S$ S$ S$
255-061 unit 1+ 60·90
Stock no. Price per OM S$ S$ S$
375-5422 unit 1+ 62·50
Stock no. Price per OM S$ S$ S$
719-0876S unit 1+ 117·00
Description Stock no. Price per OM S$ S$ S$
Magnetic field indicator, ATEX 457-8311 unit 1+ 101·50
Magnetic field indicator, IECEx 166-800 unit 1+ 96·00
The PTS 200 may be connected via the modular plug or the crocodile clips to the pair under test.
Depending on the switch position the Tone Generator will test Polarity continuity or short circuits.
The PTS 200 can be used on twisted pair wiring (Telecom, Datacom, security / alarm, audio and
electrical), single conductors, coaxial cables, de-energized AC wiring and just about any other
wiring you can think of.
PTS 100 Probe:The PTS 100 Probe has a built-in loudspeaker to make it easy to hear the tracing signals and a near/
far sensitivity Adjustment to allow both broad searches and pinpoint identification of wires. To
operate just press the button on the top and adjust the sensitivity control to hear the tone
generated by the PTS 200
Note: Only for use on non-powered cables, powered by PP3 batteries (not supplied).
Image for illustration purposes only
Description Stock no. Price
per
OM S$ S$ S$
PTS100/200 Pair Tracing Kit,BTPlug
268-357 unit 1+ 152·00
PTS100/200 Pair Tracing Kit, RJ11Plug
331-5226 unit 1+ 129·00
2273
www.nguyenxuong.com
Cable Fault Finders
LAN Test Equipment
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
Pro3000 Analog Tone andProbe Kit
701k Classic Tone and Probe Kit
Fluke TS90 & TS100
IntelliTone Probes
TES-48
540 Tone Generator and InductiveSpeaker Probe
IntelliTone Kits
The Model 701K is recognised by technicians as the industry
standard for wire and cable identification. The kit is used for
the identification of single conductors or cables within a
bundle, at a cross connect point or at remote ends. Supplied
in a sturdy woven polyester carrying case the 701K kit
comprises the 77HP High Power Tone Generator and the 200
EP Inductive Amplifier
IntelliTone� digital signal locating technology is the smarter,
faster way to locate all hidden and hard-to-find cables. LED and
Designed to make cable identification and connector tracing easier.
Rugged, battery operated, handheld LAN tester to identify cable failures
UTP, FTP and coax cabling tests
Category 5 cabling
End to end EIA/TIA 568 verification
Detects opens, shorts, mis-wires, crossed pairs, reversals and split pairs
Distance to fault location
Measures cabling length
One button test mode
Easy to read LCD display
Low battery and auto power off
99 data set memory
Identifies up to 8 different cables with cable identifiers
Can be used for cables between 1m and 350m
Faults detected: opens, shorts, reversed, crossed and split pair
Breakthrough IntelliTone� digital signal technology finds
cables other toners/probes can’t. Speeds cable location with
For toning and tracing wire on non-active networks and
specifically for identifying individual pairs with SmartTone�
technology. Angled bed-of-nails clips allow easy access to
individual wires and the RJ11 connector is ideal for use on
telephone jacks. The large loud speaker on the probe allows
you to hear through drywall, wood or other enclosures to find
wires quickly and easily. Tone signal can be sent up to 10
miles on most cables. External switch on generator allows
selection of solid or alternating tone options, indicated with
solid or flashing LEDs. Probe has adjustable volume dial
control and "quick-twist" tip for easy replacement.,Free spare
tip with "Pro3000 Tone and Probe Kit".
Fast, Accurate Wire Identification
Sends Tone to Identify Wires
Two Distinct Tone Signatures
Stock no. Price per OM S$ S$ S$
462-9267 unit 1+ 500·00
These easy-to-use testers are the
equivalent of a three-in-one tool
kit: a fault locator, a cable and
wire manager and a tone
generator with SmartTone�
technology.
advanced sensing modes. Simplified signal interpretation with smart LED
and audio indicators.
audio indicators simplify cable isolation. Works with all industry-standard tone generators.
Frequency 1000 HzTone Yes
Polarity Indication
Continuity Test
Talk Battery supply
Adjustable Volume Control
Visual and Signal Strength Indication
Large Speaker for Noisy Environments
Facility for Headset/Buttset connection
Choice of Metallic or Plastic Probe Tip
2-Line Modular Test Lead
3-Colour LED identifies AC Ring Voltage
Rugged Industrial Design
The tone Generator includes:
Rejects noise and false signals
Identifies and diagnoses POTS with multi-line Telco detect, polarity and
ring indication
Audible and visual signal indication simplifies cable location in noisy
environments
Diagnoses essential cable information with polarity, continuity, and talk
battery
Safely and effectively tones active networks
Additional probes can be ordered separately
Accessories
Rejects noise and false signals using IntelliTone� digital signal technology (with
Intellitone Toner)
Locates hard-to-find cables, even on active networks
Speeds cable isolation with thumbwheel controlled sensing modes
Simplifies signal interpretation with smart audio and LED signal indicators
Extended battery life with auto power-off
Description Stock no. Price per OM S$ S$ S$
Pro3000 Tone and Probe Kit 503-568 unit 1+ 150·50
Gain 26 dB Voltage Protection (continuity mode) 52V d.c. @ 600ΩTransmitter Power 7dB @ 600Ω Talk Battery 4.5V d.c @ 600ΩWeight Including Battery 170/140 g
Works on any multiple core
(2+) cable up to 760m (TS90)
or 914m (TS100)
Instantly measures distance to
open-circuit or any fault from
one end of any cable pair
Patented SmartTone� tone
generator positively identifies
RJ11 connector, RJ45 jack and pair of alligator clips
pair
Measures cable distance on reel
Displays distance reading rather than waveform
Large LED screen
High voltage detection
Moisture-proof
One-button operation
Auto power-off after 5 minute disconnection
Validates twisted-pair installation with visual end-to-end cablemap (Intellitone 200 only
with toner)
The probe is directly compatible with Wavetek LT8000 Series LAN cable
tester’s tone generator function.
Stock no. Price per OM S$ S$ S$
370-5247 unit 1+ 235·00
In addition the IntelliTone 200 identifies, diagnoses, and troubleshoots
datacom/telecom services
The IntelliTone 200 also validates twisted-pair installation with visual
end-to-end cablemap
Supplied with: BNC to alligator clips adaptor
Description Stock no. Price
per
OM S$ S$ S$
IntelliTone 100Probe
513-6261 unit 1+ 155·00
IntelliTone 200Probe
513-6463 unit 1+ 196·00
For additional or replacement Intellitone Probes see 513-6261 & 513-6463
Traces end-to-end connections
Identifies and locates voice and data wiring and terminations
Sends and detects standard signals and checks continuity
LEDs provide visual indication of correct wire
Adjustable volume on probe
Rubber tipped probe will not break or crack
Standards: CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No. 1010.1-92, CSA-C22.2 No.1010.1B-97, UL/ANSI 3111-1
Description Stock no. Price per OM S$ S$ S$
IntelliTone 100 kit 513-6457 unit 1+ 275·00
IntelliTone 200 kit 513-6479 unit 1+ 375·00
Supplied with: PP3 9V batteries installed.
Input Protection 250 V rms ac, continuous or intermittent Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Maximum cable length TS90 2500 feet (760m), TS100 3000 feet (915m) Minimum length Minimum non-zero reading is 2 feet (0.6m) Representative maximum cable lengths 2500 feet: CAT-5 Twisted Pair
2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet (150m): RG-174/U Coax
Length Accuracy ±2 ft for cables < 10ft, ±5 ft for cables > 10 ft and < 200 ft, ± (3% rdg + 5 ft) for cables > 200 feet
High Voltage Detection Warning occurs for AC voltage > 5Vrms Measurement Rate Maximum of 4 complete measurements per second Measurement Technology Time Domain Reflectometry (TDR)
50 Ω drive impedance, 6 V maximum pulse height. VOP (Velocity of propogation) Adjustable from -20- to -99-, retained during power off.
Default to -66- when batteries are changed. Tone Injection Typically 1 kHz at an amplitude of 80% of battery voltage. Cable Type Virtually all two or more conductor cables Power 4 x AA alkaline battery, reverse polarity protected Low battery warning Indicator flashes when battery voltage falls below 4.1V Temperature Range - Operating 0 to 55°C (32 to 131°F) Temperature Range - Storage -40 to 70°C (-40 to 158°F) Size and Weight 188 x 70 x 38 mm, 450 g
Stock no. Price
per
OM S$ S$ S$
326-7694 unit 1+ 189·00
Description Stock no. Price per OM S$ S$ S$
Fluke TS90 543-352 unit 1+ 350·00
Fluke TS100 543-358 unit 1+ 540·00
2274
www.nguyenxuong.com
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Visit our website for additional price information and exciting promotions
CableIQ Residential Qualifier
LinkRunner NetworkMultimeter
LinkRunner Pro NetworkMultimeter
LinkRunner Duo NetworkMultimeter
NetTool VoIP
MicroScanner2 Professional Kit
CableIQ Qualification Tester
LinkRunner Duo enables technicians to resolve a broader range
CableIQ Tester with remote adapter is a qualification tool
designed for network technicians who need to troubleshoot
connectivity problems and qualify cabling bandwidth.
LinkRunner Pro enables technicians to resolve a broader range
CableIQ is the first qualification tester designed for residential
installers who need to document that cabling systems are
installed properly and will perform reliably. It quickly qualifies
residential cabling systems to support voice, VoIP, 10/100/
1000 Ethernet and CATV and presents results in the form of
professional test reports. Designed especially with the
residential installer in mind, CableIQ is versatile and intuitive
enough to replace multiple tools for testing, ID-tagging and
troubleshooting all voice, data, video, audio and security
cabling.
Has all of the test capability of the MS2-100, but includes all
accessories in a single, preconfigured carry case.
Solve PC-to-network connectivity problems faster with NetTool.
See inline between the PC and network to quickly verify
Contents
connection speed, duplex, utilization, link configuration, health information
and network resources. View services offered, name, IP address and subnet.
Problem log alerts, duplicate IPs, unanswered DNS queries, TCP/IP
connection failures and more.
of today’s connectivity problems. Unlike traditional 10/100 link
testers, LinkRunner Pro verifies Gigabit link – increasingly important
for today’s high-performance networks. It also pings up to 10 key
devices, detects Power over Ethernet (PoE), resolves 802.1X security
conflicts, verifies cable wiremap, and identifies the nearest switch
port with Cisco, Extreme and IEEE Link Layer Discovery Protocols
(CDP/EDP/LLDP). Built-in IntelliTone digital toning precisely locates
cables at patch panels and switches. Link status reports can be
uploaded from USB port and routed with trouble tickets to expedite
problem resolution.
of today’s copper and fibre link connectivity problems. Unlike traditional 10/100
link testers, verifies Gigabit link – increasingly important for today’s high-
performance networks. It also pings up to 10 key devices, detects Power over
Ethernet (PoE), resolves 802.1X security conflicts, verifies cable wiremap, and
identifies the nearest switch port with Cisco, Extreme and IEEE Link Layer
Discovery Protocols (CDP/EDP/LLDP). Built-in IntelliTone digital toning precisely
locates cables at patch panels and switches. Link status reports can be uploaded
from USB port and routed with trouble tickets to expedite problem resolution.
Troubleshoots why existing cabling plant can’t support
the desired network bandwidth
Discovers what’s at the end of any cable and displays
device configuration (speed/duplex/pairing)
Frees-up switch ports and identifies unused links
Graphically maps wiring configuration and shows
distance to faults with Intelligent Wiremap
Tests all copper cabling media: twisted-pair, coax, and
audio cabling
Locates and traces cable with IntelliTone� digital
Documents that residential cabling systems are defect-free and TIA-570B compliant
Qualifies residential cabling systems to support voice, VoIP, 10/100/1000 Ethernet and CATV
Graphically maps wiring systems and shows distance to faults with built-in TDR
Tests and troubleshoots all low voltage residential wiring: coax cables, telephone wire, security
wire and speaker wire
Locates and traces cables with IntelliToneTM digital signalling technology (IntelliToneTM probe
available separately (stock no. 513-6261 or 513-6463)
Link at 10/100/Gig – identify device capabilities and confirm actual speed/
duplex status
Ping key devices – measure response of DHCP, router, DNS, and other
devices or URLs
Verify 802.1X settings – authenticate with EAP type, user name, certificates,
and password
Supplied with: CableIQ main unit (CQI 100), RJ45 patch cord (2), RJ11 patch cord (2), USB cable, bare
wire adaptor, speaker wire adaptor, coax cable, coax BNC adaptor, coax RCA adaptor, ’Qualified’ labels
(50), CD ROM user manual, getting started guide, AA batteries (4), soft carrying case.
Quickly solve PC-to-network connectivity problems on networks which
are active
Verify network drops; link connectivity, speed, duplex settings, finds
faults and cable length
Identify PC network configuration devices used and problems
Identify available network resources and services offered
Ping network devices using IP or DHCP
Download and print reports
Watch VoIP phones boot
Monitor VoIP phone and system performance
Validate QoS configuration
Log call control
Monitor call quality metrics
Detects opens, shorts and split pairs
LinkRunner�, the essential personal tool which lets
you quickly verify and troubleshoot network drops.
Identifies 10BASE-T, 100BASE-TX FDX/HDX, Token
Ring, Telco, Cable ID, un-powered PC or hub, Auto-
MDIX port. Cable tests: length, open, short, splits,
wiremap, crossed, straight through, plus tone.
Auto-negotiation and link verification via static IP
signaling technology
Link at 10/100/Gig – identify device capabilities and confirm actual
speed/duplex status
Ping key devices – measure response of DHCP, router, DNS, and
other devices or URLs
MicroScanner2 with main wiremap adapter
Remote identifiers #2-7
IntelliTone Pro 200 probe
Shielded twisted-pair RJ45 patch cord
RJ11 patch cord
Clip-set - RJ45 to 8 alligator clip test lead
Bare wire adapter
F Coax push on patch cord
Accessory soft pouch
2 x AA alkaline batteries
1 x 9V alkaline battery
Getting Started Guides
Owners CDs
Packaged in a deluxe Fluke Networks carry case.
Description Stock no. Price per OM S$ S$ S$
Cable identifiers 2,3,4 425-0798 unit 1+ 48·50
Description Stock no. Price per OM S$ S$ S$
NetTool VoIP 540-8285 unit 1+ 3730·00
Kit includes Cable IQ tester with remote adapter, IntelliTone 200 Probe, six remote IDs and rugged
carrying case
Detect PoE service – verify voltage level, and pairs to IEEE 802.3af specifications
Identify switch port – supports Cisco, Extreme, and IEEE Link Layer Discovery Protocols
Test cable wiremap – measure length; detect miswires, shorts, split pairs or opens
Locate and ID cable – use IntelliTone or optional IDs to locate cables at patch panels
Document results – upload link status reports with USB port for faster problem resolution
Verify 802.1X settings – authenticate with EAP type, user name, certificates, and password
Detect PoE service – verify voltage level, and pairs to IEEE 802.3af specifications
Identify switch port – supports Cisco, Extreme, and IEEE Link Layer Discovery Protocols
Test cable wiremap – measure length; detect miswires, shorts, split pairs or opens
Locate and ID cable – use IntelliTone or optional IDs to locate cables at patch panels
Document results – upload link status reports with USB port for faster problem resolution
address or DHCP. Includes LinkRunner� Wiremap Adaptor.
Stock no. Price per OM S$ S$ S$
369-554 1 kit 1+ 1750·00
UTP Yes STP Yes
Supplied with: LinkRunner Duo, Wireview Cable ID #1, LinkRunner Connect Software CD, USB cable,
RJ45 coupler, LinkRunner Duo getting started guide, four (4) AA alkaline batteries.
Description Stock no. Price
per
OM S$ S$ S$
Cable IQ tester withpouch
513-6435 unit 1+ 2150·00
Cable IQ Kit 513-6441 unit 1+ 2900·00
Description Stock no. Price
per
OM S$ S$ S$
LinkRunner Pro NetworkMultimeter
134-443 unit 1+ 1870·00
LinkRunner Pro Extended TestKit
134-419 1 kit 1+ 2820·00
Cable tests: length, open, short, splits, wiremap, crossed, straight
through
View Link, Length, Ping for each drop
Link: Check PC drops for connectivity, speed and duplex settings
Length: Checks cable configurations, finds faults and length
Ping: Verifies connectivity to key network resources and PC NIC
response
Stock no. Price per OM S$ S$ S$
624-7441 unit 1+ 2320·00
Manu. Part No. Stock no. Price per OM S$ S$ S$
LR DUO 672-7559 unit 1+ 2450·00
Description Stock no. Price per OM S$ S$ S$
Link Runner 513-6334 unit 1+ 840·00
Link Runner Test Kit 513-6340a unit 1+ 2055·00
RJ45 UTP 340-9624 unit 1+ 11·80 15+ 11·00 25+ 10·50
Accessories
Description Stock no. Price
per
OM S$ S$ S$
MS-SX Fibre SFP Trans.Module
672-7552 unit 1+ 325·00
MS-LX Fibre SFP Trans.Module
672-7556 unit 1+ 620·00
MS-FX Fibre SFP Trans.Module
672-7565 unit 1+ 800·00
2275
www.nguyenxuong.com
IDC Cable Tester
Wiring Testers
PC Cable Checker
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple ➤ Indicates more pricing available online a New product to range
IDC Cable Tester
Network Cable Tester
Linkmaster
Shielded Type II
LAN Tester & Remote
RJ45/RJ11 Continuity
NetTool Series II
PC Cable Checker
A compact microprocessor controlled cable tester enabling
quick and reliable wiring configuration checks of cables
terminated with the most popular sizes of IDC connectors,
ranging from 10 way up to 64 way. This versatile cable tester
allows the user to identify a correctly made standard ribbon
cable or to carry out a rapid comparison test with a known
"good" custom made cable.
Data wiring tester consisting of master and remote units,
designed to check the integrity of 2, 3 and 4 pair voice and
data channels with a loop distance of up to 3048 metres.
Three jack sockets are incorporated into each half to enable
8 way RJ45 USOC, 568A and 568B sequences to be checked.
Sockets are fully shielded enabling the testing of both UTP
and STP/FTP wiring systems.
A compact and portable, versatile cable tester that quickly and reliably
checks PC cables using any combination of many of the most popular
computer connectors.
Two piece tester includes main unit and remote with test results at
both ends.
Small hand-held tester with one remote, allowing one-person testing
Quickly tests twisted pair cable
Checks continuity and configuration
Debug mode for fault and pair identification
Tests all common data wiring configurations
Faults detected: shorts, opens, miswires, reversals and split pairs
Accepts most centre polarised and unpolarised IDC sockets,
with any combination of 10, 14, 16, 20, 26, 34, 40, 50, 60or 64 way housings, terminated at either end of the ribbon
Conveniently checks the continuity of screened/unscreened
telephone and computer link cabling systems (up to
1000ft/0.3km). The tester accommodates RJ11/RJ45, and DEC
type plug interfaces. An immediate, simple, visual LED
indication is provided of line continuity, by depressing a
conveniently located push-button switch to initiate a test cycle.
This basic level network tester will comprehensively test
each twisted pair through RJ45 or RJ11 connectors and
comes with remote end terminator for testing link and patch
cords. An easy red and green light system will notify you of
which pairs are fully functional and which are faulty.
One button, simple testing (PASS/FAIL or fault find)
Traces wires with tone & remote lights
Quick fault analysis on coax & data cables
Cat 5, Cat 5e or Cat 6 (UTP/STP) cable testing (may not be
compatible with Cat 6 flat or oval cable, or bonded cable)
Detects opens, shorts, crossed wires and split pairs
Compact & lightweight
Easy to read LEDs with immediate pass/fail indication
Maps both cable ends instantly
Identifies continuity, opens, shorts and cross connected wires
Checks RG58, 59, 62 BNC connectors
Checks RJ11 and RJ45 connectors
Checks 9, 15 and 25 way D connectors
Checks 15 way HD connector
Checks 36 way Centronics
Checks shield continuity
9V PP3 battery included
NetTool Series II combines powerful
NetProve diagnostics, inline Gigabit
vision, digital IntelliTone technology
Continuously sequenced LED display provides immediate
diagnosis of standard wiring faults
Fully testable shield continuity
Master and remote units snap and lock together for easy
carriage and storage
Faults detected: shorts, opens, miswires, reversals and
Tests for: open, shorted, crossed, reversed, transposed, split,
non-pair wiring
cable.
Remote terminator to test links and patch cords
Test for faults such as mis-wiring, short or reversed
wires or broken connections
For use on RJ45 connectors
Adapters included for RJ11 connectors
Supplied with: 1x6V PX2SL battery
split pairs
Supplied with: 9V PP3 battery
Kit Contents
and network, IP Phone and PC configuration testing in one
palm-sized tool. Solve PC-to-network connectivity
problems faster with NetTool. See inline between the PC
and network to quickly verify connection speed, duplex,
utilization, link configuration, health information and
network resources. View services offered, name, IP address
and subnet. Problem log alerts, duplicate IPs, unanswered
DNS queries, TCP/IP connection failures and more.
Bright LEDs clearly indicate PASS, FAIL, OPEN and SHORT conditions
Includes MEMORY facility to reduce test time
LED self test and "power down" facility to conserve battery life, supplied with comprehensive
instruction manual
Accepts 4 x AAA batteries (alkaline or zinc chloride) which should be ordered separately
Stock no. Price per OM S$ S$ S$
328-7856 unit 1+ 188·50
Stock no. Price per OM S$ S$ S$
629-5226 unit 1+ 360·00 5+ 320·00 10+ 315·00
Contents
Port interface RJ11, RJ45 or DEC Position access time 1 second I/O current 5mA (max.) Power consumption 35 m W
Network Tester
Remote End Terminator
2 x RJ11 adapters
Stock no. Price per OM S$ S$ S$
301-9697 unit 1+ 790·00 5+ 710·00
Main & Remote
2 RJ45 patch cords
2 Belt clips
The tester requires a PP3 9V battery.
NetProve� diagnostics – isolate device and application
Type UTP/STP Application Tests all common data wiring configurations Short Circuit Yes Coax Yes Open Circuit Yes STP Yes Split Pair Yes UTP Yes
Instructions manual
connectivity issues in seconds
Inline Gigabit vision - quickly troubleshoot network problems with powerful inline vision into 10/
100/Gig traffic between switches, PCs, IP phones and other devices
PoE Measurements - verify readiness of PoE systems and troubleshoot PoE device problems
Spot available network resources – See MAC and IP addresses, subnet and services offered by
active servers, routers and printers
IntelliTone digital signaling - quickly and safely locate cables on active network
Quickly solve PC-to-network connectivity problems
Verify network drops; link connectivity, speed, duplex settings, finds faults and cable length
Identify PC network configuration devices used and problems
Identify available network resources and services offered
Ping network devices using IP or DHCP
Download and print reports
Short Circuit Yes UTP Yes Open Circuit Yes STP Yes Miswire Yes Coax No Split Pair Yes
Stock no. Price per OM S$ S$ S$
233-8919 unit 1+ 295·00 3+ 275·00
Stock no. Price per OM S$ S$ S$
387-928 1 kit 1+ 230·00 6+ 215·00
Note: Does not include 9V battery (required).
Description Stock no. Price per OM S$ S$ S$
NetTool Series II Pro 134-415a unit 1+ 5130·00
NetTool Series II VOIP 134-409a unit 1+ 6163·00
Stock no. Price per OM S$ S$ S$
215-6391 unit 1+ 225·00 3+ 210·00
Type Cable Tester Miswire Yes Short Circuit Yes Application Pair testing of RJ11/RJ45 connections Open Circuit Yes Coax No
Stock no. Price per OM S$ S$ S$
557-414 unit 1+ 76·50 3+ 71·00
2276
www.nguyenxuong.com
Fibre Optic Test Equipment
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
New products available online every week
Visifault
Visual Fault Finder
FibreMASTER�
SIGNALTEK� - FO
Fibre Inspector PRO�
MicroMapper� WiremapChecker
VDV Pro Cable Tester
IENet Pro Tester
Quickly and easily verify the integrity of an Ethernet twisted-pair
The laser-powered Visifault locates fibres, verifies continuity
and polarity, and helps find breaks in cables, connectors and
Dirt, dust and other contaminants are the enemies of high-
speed data transmission over optical fiber. Today’s network
Easy-to-use cable tester for 2 pair and 4 pair industrial ethernet cabling. Shielded
2 pair, M12 and RJ45 ports ensure compatibility with most Industrial Ethernet
The VFF5 visual Fault Finder is a light source used to locate breaks
and bad connections in fibre optic cables. It is ideal to verify
continuity, test and find breaks in LAN’s, fibre data links and
loops.
Cable testing and verification device that quickly tests all wiring requirements in
residential and commercial environments. Dockable remote with RJ11/RJ12, RJ45
and coax interfaces, stores securely in base of main unit making it easily available
and ready for fast cable testing.
Offers capabilities such as Gigabit Ethernet Qualification,
test storage and reporting, and active link testing and adds
the powerful capability of fiber optic Qualification.
Voice - tests 3 pair USOC and 6-position RJ11/RJ12 jacks
Data - tests shielded and unshielded cable to T568A/B standard
Video - tests coax cable for opens, shorts and length with F-connector interface
Blinks network link LED for visual cable tracing
Multi-tone support for cable tracing and fault isolation
cabling installation with MicroMapper�, a compact, handheld cable tester designed
for network professionals. One button test looks for opens, shorts, crossed, reversed
and split pairs. Separate remote unit for easy, one-person testing of installed cabling
or patch cords is included.
Finds breaks, faulty splices and crimps, poor components or
connections
Slim, pocket sized and battery powered
Can be used for both single-mode and multimode cable with a
4km range
Continuous (CW) or Modulated (MOD; 1Hz Pulse) modes
Accepts ST, SC and FC connectors
Requires 2 x AA batteries (stock no. 591-225)
splices.
cabling.
A fibre optic power meter and light source.
applications require more bandwidth, making loss budgets tighter than ever. It is
critical that all optical connections are clean and free of contaminants to ensure
application success. The Fluke Networks FiberInspector Pro� video microscope
puts the solution to contaminated end-faces right before your eyes. This portable
video microscope works ten times faster than traditional scopes.
Wave Lengths 650 ±10 nm
Bright red visible laser light source
Accelerates end-to-end fibre continuity checks
Speeds fibre tracing and identification
Simplifies fibre polarity verification
Aids in location of fibre faults including tight bends, breaks and bad
connectors
Features continuous and flashing modes
Rugged case helps protect against accidental damage caused by
impact or vibration
Over 80 hours of battery life with 2 AA batteries
Handy lanyard attachment and carrying case
Features - Power Meter
Tests twisted-pair cables automatically for continuity and all major miswires
Speeds troubleshooting with easy-to-read pair-based LED fault indicators
Identifies hidden cables clearly with powerful inductive tone generator
Enables one-person testing of installed cables with separate remote unit
Tests twisted-pair cables for opens, shorts, crossed pairs, split pairs or any
miswires.
Description Stock no. Price
per
OM S$ S$ S$
VDV Pro 1 remote 702-3974 unit 1+ 410·00
VDV Pro 8 remotes 702-3978 unit 1+ 600·00
VDV Pro 1 remote and probe 702-3984 unit 1+ 440·00
Dual-magnification probe allows quick changes between 250x and 400x
Large 3.5" (9cm) display provides crisp, clear images of microscopic debris and
end-face damage
Troubleshooting is 10 times faster than with traditional scopes
Various probe adapter tips allow for inspection through many different
connector port types
Rugged carrying case and protective boot prevent damage
Simple selection between voice, 2 and 4 pair data and coax testing functions
Tests for opens, shorts, miswires, reversals, split pair and length
Indicates correct wiremap to T568A/B standards for shielded and unshielded
Identifies presence of voltage on cables
Tone generator supports four different tones making fault isolation easier
Integrated RJ45 (UTP/STP) and shielded M12 interfaces on top of unit
Detachable remote with RJ45 and shielded M12 coax interfaces
Can support additional remotes making it efficient for one person testing
Blinks network link LED for visual cable tracing
Numerical indication for UTP "No Shield" and STP "Shield"
Traditional power meter/light source kits only measure the attenuation of fiber
optic links. As Gigabit Ethernet is becoming the standard for backbone and zone
fiber optic cabling, attenuation tests alone may not be enough to guarantee
error-free performance. SIGNALTEK-FO’s Bit Error Rate testing, adds assurance
that fiber optic links can actually support high-speed data in accordance with
IEEE 802.3ab standards.
Multimode and single mode capability
Measure cable attenuation with a dynamic range of up to 20dB
Guarantee link operation at 1Gbps within IEEE error tolerances
Supplied with: FT650 Fiber Probe, FT630 Fiber Display, AC adapter/battery
charger, probe adapter tips (ST, SC, FC and universal 2.5mm patch cord tip) and
hard carrying case
Description Stock no. Price per OM S$ S$ S$
IENet Pro with 1 Remote 702-3987 unit 1+ 630·00
IENet Pro with 8 Remote 702-3980 unit 1+ 880·00
Wave Lengths 650 nm
Stock no. Price per OM S$ S$ S$
324-9416 unit 1+ 910·00
Stock no. Price per OM S$ S$ S$
513-6485 unit 1+ 230·00
850, 1300/1310, 1490 and 1550 wavelength measurement
FT630 Display
Display type 3.5 in (9 cm) TFT, active matrix
Display resolution 320 x 240 pixels
Video output NTSC
Power source Lithium Ion or AC power
Battery life 2 hours continuous use
Size and Weight 100 x 53 x 220 mm, 400 g
FT650 Fibre Probe
Magnification Low: 250 x
High: 400 x
Camera type 0.33 in (8.38 mm) CCD with adjustable focus
Light Source LED
Lighting technique Coaxial
Size and Weight 45.7 x 43.2 x 140 mm, 180 g
Stock no. Price per OM S$ S$ S$
540-8308 unit 1+ 540·00
capability
Power measurement in dBm and mW, loss display in dB
Auto Power Off
Includes universal adapter
Operates on standard 3xAAA batteries
Kit Contents
Features - Light Source
1 SIGNALTEK fiber ready near-end and 1 remote-end handset
Carrying case
Copper cable accessory kit with interfaces to RJ45, RJ11, Coax F-Type
cables, and alligator clips
Fiber optic cable accessory kit: 2 duplex LC-SC 50/125μm (2m/7ft) cables, 2
duplex LC-SC 62.5/125μm (2m/7ft) cables, 1 duplex SC-SC adapter.
8 AA alkaline batteries
2 AC power adapters with international plugs
USB interface cable
1 CD-ROM User Manual
1 Training DVD
Stock no. Price per OM S$ S$ S$
543-891 unit 1+ 6243·00
850 nm light source
Includes ST, SC and FC adapters
Power LED – lights green when light source is active
Docks in the bottom of the power meter for easy storage
Operates on standard 3xAAA batteries
Low battery indication
Wave Lengths 850 nmCable Type Data, Coax, Fibre Optic
Operating Range (dB) -60 → +3 Cable Type Single Mode and Multimode Wave Lengths 850, 1300/1310, 1490, 1550 nm
Stock no. Price per OM S$ S$ S$
563-980a unit 1+ 3551·00
Stock no. Price per OM S$ S$ S$
563-986a unit 1+ 1020·00
2277
www.nguyenxuong.com
Wi-Fi Test Equipment
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple a New product to range
FTK1000/2000 SimpliFiber ProBasic Verification Kit
FTK1300 SimpliFiber ProVerification Kit with FT120
FTK1350 SimpliFiber ProVerification Kit with FT500
FTK1450 SimpliFiber ProComplete Verification Kit
SimpliFiber Pro Cord Sets
AirCheck� Wi-Fi Tester
SimpliFiber Pro Power Meter
SimpliFiber Pro SinglemodeSource
Handheld wireless tester for 802.11a/b/g/n supported networks.
Integrates all Wi-Fi technologies plus interference detection,
Full-featured verification kit with FibreInspector Mini
Optical power meter with the ability to save a reference power
level, allowing direct display of fibre loss.
Starter kits for contractors and network technicians who install
Provides optical power at 1310nm and 1550nm. The source is
Full-featured verification kit with FibreViewer
and maintain fibre links. Available in singlemode or multimode
configurations, quickly verify optical loss and power levels at 850
and 1300nm or 1310 and 1550nm. Add additional sources,
microscopes, and VFL options as needed.
Kit Contents
Fibre optic test reference cord sets
Calibrated for accuracy at 6 different wavelengths (850, 1300, 1310, 1490, 1550,
1625)
Intuitive four button panel
Large LCD screen
USB serial port
channel scanning and connectivity tests. Troubleshoots the most common
Wi-Fi pain points, including;
used with SimpliFiber Pro optical power meter for testing singlemode fibre optic
cable.
Kit Contents
Complete fibre verification kit with
FibreInspector Mini
Kit Contents
Description Stock no. Price per OM S$ S$ S$
62.5 uM SC/ST cord set 1m 661-9063a unit 1+ 176·00
Supplied with: SC adapter and carrying pouch.
Dual 1310/1500 FP laser emitter
Fixed SC optical connector
Kit Contents
Coverage problems
Overloaded networks or channels
Interference
Connectivity problems
Failed access points
Rogue access points
Security settings
Client problems
SimpliFiber Pro optical power meter
850/1300nm source (SC port)
FindFibre Remote ID source
FT120 FibreViewer optical microscope
VisiFault VFL
LC and ST adapters
Carrying case
SimpliFiber Pro optical power meter
850/1300nm source (SC port)
FindFibre Remote ID source
FT500 FibreInspector Mini video microscope
VisiFault VFL
LC and ST adapters
Carrying case
Supplied with: AirCheck tester, USB cable, soft case, Getting started
guide, AirCheck Manager software CD and user manual.
SimpliFiber Pro optical power meter
Supplied with: 2xAA batteries and instruction sheet.
Resolution (dB) 0.01 Wave Lengths 850, 1300, 1310, 1490, 1550, 1625
SimpliFiber Pro optical power meter
Source
SC power-meter adapter
Carrying case
Wave Lengths 850, 1300 nmCable Type Multimode
Wave Lengths 850, 1300 nmCable Type Multimode
Cable Type Stock no. Price per OM S$ S$ S$
Multimode 661-9045 unit 1+ 5540·00
Manu.
Part No.
Wave
Lengths
(nm)
Cable Type Stock no. Price
per
OM S$ S$ S$
FTK1000 850, 1300 Multimode 661-9048 unit 1+ 4140·00
FTK2000 1310, 1550 Singlemode 661-9041 unit 1+ 4930·00
Stock no. Price per OM S$ S$ S$
702-6850 unit 1+ 4590·00
Stock no. Price per OM S$ S$ S$
661-9054 unit 1+ 10800·00
850/1300nm source (SC port)
1310/1500nm source (SC port)
2 x FindFibre Remote ID source
FT500 FibreInspector Mini video microscope
VisiFault VFL
LC and ST adapters
NFC-KIT-BOX cleaning equipment
Carrying case
Wave Lengths 1310, 1500 nmCable Type Singlemode
Stock no. Price per OM S$ S$ S$
661-9023 unit 1+ 1630·00
Accessories
Wave Lengths 850, 1300, 1310, 1500 nmCable Type Multimode and Singlemode
Accessories
Accessories
Accessories
Stock no. Price per OM S$ S$ S$
661-9032 unit 1+ 2990·00
Stock no. Price per OM S$ S$ S$
661-9057a unit 1+ 11121·00
Description Stock no. Price per OM S$ S$ S$
FT-120 Viewer 200x 389-3423 unit 1+ 880·00
FT-140 Viewer 400x 389-3439 unit 1+ 860·00
Description Stock no. Price per OM S$ S$ S$
FT-120 Viewer 200x 389-3423 unit 1+ 880·00
FT-140 Viewer 400x 389-3439 unit 1+ 860·00
Description Stock no. Price per OM S$ S$ S$
FT-120 Viewer 200x 389-3423 unit 1+ 880·00
FT-140 Viewer 400x 389-3439 unit 1+ 860·00
Description Stock no. Price per OM S$ S$ S$
Antenna 702-6863 unit 1+ 445·00
Li-On Repl. Battery 702-6866 unit 1+ 560·00
Auto Charger 702-6860 unit 1+ 84·50
AC Charger 702-6879 unit 1+ 197·00
2278
www.nguyenxuong.com
Line Monitors
Test Telephones
Breakout Boxes
Line Monitors
Network, Cable & Electrical TestingORDERLINE65 6865 3433
93
Many more leading brands from over 2,500 suppliers available online
Mini RS-232 Monitor
www.rssingapore.com
Oscar 250
All the telephones in this range have a high impedance passive monitor, last number redial, tone-pulse
dialling and time-break recall.
Dual Standard – DSTS 2 with DSP
www.rssingapore.com
Comtest 100C
Breakout boxes designed for rapid
checking and trouble shooting of
computer interfaces especially EIA
RS-232C (V24). The LEDs are
illuminated when signals are
present and the user may break
the signal lines by means of the
front panel dip switches and send
these signals to other lines via the
jumper wires supplied. This is
typically the method used when
pins 2 and 3 need to be cross-
wired for null modem
operation.,This break-out box
displays signals that conform to
Line monitors designed for
rapid checking and trouble
shooting of computer
interfaces especially EIA
RS-232C (V24)
Conforms to RS-232 and
discriminates against out of
tolerance signals
The LEDs on the front panels
of the testers are generally on
the signal originating side of
the unit, allowing the signal to
be broken yet remain
monitored
Separate RED and GREEN
LEDs ensure unambiguous monitoring
RS-232 and discriminates against out of tolerance signals.,The LEDs on the front panels of the testers
are generally on the signal originating side of the unit, allowing the signal to be broken yet remain
monitored. Separate RED and GREEN LEDs ensure unambiguous monitoring. RED - MARK condition
(1); GREEN - SPACE condition (0); RED and GREEN - Pulse train; Both OFF - no (or out of spec) signal.
Complete RS-232 troubleshooting tester for both DB9 and
DB25 connections
Breaks and redirects all 25 lines
102 high efficiency LED indicators
Four-state monitor on all signal lines on both DTE and
DCE
Four level bi-directional Current Loop test (4, 10, 20 and
60mA)
Ground Potential Difference test
Two DB9/25 adaptors
Oscillator and auto-ranging dB meter
suitable for any use involving the distribution
The DSTS 2 first introduced in 1988 has remained a favourite
with many telephone administrations around the world
because of its reliability and ease of use. Since its
introduction, the design has evolved in line with changes in
the technology and services deployed in the telephone
network to its present form incorporating DSP
technology.,Digital Services Protection (DSP) Test Telephones
are designed to operate safely in situations where telephone
wiring may be carrying Digital traffic, Voltage feed to remote
electronics or Hazardous voltages that result from fault
conditions or misuse of the cable
18 LEDs (9 Green, 9 Red)
Pins monitored are 2 (TXD), 3 (RXD), 4(RTS), 5 (CTS)
(DSR), 8 (CD), 20 (DTR), 11 (HS), 19(HS)
All lines are wired pin to pin
The unit has a 25-way ’D’ connector M-F line installation
500 mating cycles
30V operating voltage
30mA, 15 mΩ contact rating
Dimensions: W. 53mm D. 53mm H. 16mm.
Conversion pin-out table on rear of unit
Jumper cable set and detachable 300mm ribbon cable
Easy operation
Compact and lightweight
Battery powered (requires 1x9V PP3 battery, eg. stock no. 394-9059)
Stock no. Price per OM S$ S$ S$
202-537 unit 1+ 49·30 3+ 45·80
Digital circuit safety
Excessive voltage alarm
Automatic lock-out
No Battery Required
Tone/ pulse
Last Number Redial
High Impedance Monitor at normal listening levels
or broadcasting of audio level signals
Can be used for fault location and lining up of data/speech networks
Independent operation
Calibration in dBM
True r.m.s. reading
+10 to -50dB range
Provides a d.c. patch for control signals and line hold in telecom
applications
Built-in switchable 600Ω termination
Switchable tone source built-in
Stock no. Price per OM S$ S$ S$
360-1476 unit 1+ 390·00 3+ 365·00
3-Digit Receiver Send Frequency 800Kz to 1600Hz Resolution 0-01dB Output Impedance 600Ω with d.c. path Frequency Range 100Hz to 100Hz Power Supply 9V PP3 battery supplied Receiver Terminations (1) through – 17kΩ
High monitor level
High impact resistance
High chemical resistance
Easy non slip shoulder placement
Tone/Pulse operation
Redial in Tone and Pulse
Timed Break Recall (Flash)
Polarity Check
Ground Start/ Earth Calling
Full operation at 10mA
Protection against direct battery connection
Belt clip/hanging loop
Stock no. Price per OM S$ S$ S$
252-756 unit 1+ 630·00
Crocodile Clips (not included, order separately)300mm long lead terminated by 608A UK socket and 3 crocodile clips (earth lead is 430mm).
Krone LSA Plug (not included, order separately)235mm long lead terminated by 608A UK socket and a Krone LSA plug with an earth crocodile clip.
DC Parameters 50V, 200Ω Transmission Auto gain controlMax. o/p limitation 1.4V rms.4dB octaveRoll, off above 4KHz
Max Line Resistance 4KΩ Reception Acoustic shock protectedDynamic receiver
Current Range 10mA - >90mA Cordage CW1311 cordage with 431A plug Impedance (ReturnLoss)
>16dB 300-3.4KHz Safety Cord - case insulation. >50MΩ
Protected against 50V raw batteryindefinitely Lighting inductionprotection
Monitor >10K 0-8KHz Standards BS 6317, BS 6305, BS 2011 Dialling Loop disconnect, DTMF, LNR Approvals BABT
Description Stock no. Price per OM S$ S$ S$
DSTS 2 Test Telephone 801-522 unit 1+ 260·00
DSTS 2 - Crocodile Clip 341-3550 unit 1+ 37·70
DSTS2 - Krone LSA Plug 341-3566 unit 1+ 68·50
2279
www.nguyenxuong.com
Network, Cable & Electrical Testing ON-LINEwww.rssingapore.com
93
OM = Order Multiple
Fluke TS42DLX
www.rssingapore.com 65 6865 3433
Fluke TS25DData lockout and data lockout override
DSL/POTS filtering technology allows user to safely draw
The TS42 test set combines rugged DropSafe� and best-in-
class DataSafe� protection with waterproof durability, and
dial tone from a pair that is carrying voice and ADSL without
downing the ADSL service
Built-in analog tone generator for tracing and identifying
wires with a probe
DTMF digit-grabbing capability
Talk battery to supply power to non-powered (dry) pairs to
carry voice conversation
Row/column tones for single tone dialing
High voltage Lockout/Low voltage Lockout
Continual data detection in monitor mode
Amplified speaker for hands-free monitoring
Programmable phonebook stored in non-volatile memory
Speed dial (10 memories, 23 digits each)
Selectable flash and pause duration
Battery level indicator
provides powerful and versatile testing capabilities.
Superior high-impedance monitoring protects data lines
2-way hands-free speakerphone capability
Passive monitor
Over-voltage & current protection
Rugged, ergonomically designed waterproof case design for severe
weather conditions, exceeds US Mil Spec MIL-STD-810E
DropSafe� 20ft onto concrete
Top or bottom mountable, with extra large steel locking belt clip
Line-cord strain relief
Mute & polarity indication
Tone & pulse dialing
Last number redial & Speed dialing
PBX pause button
Audible ringer & Amplified speaker
Volume control levels
Hearing-aid compatible
Line and battery powered, with low battery warning
Note: This product has been safety certified for indoor use only.
Standards: Conforms to relevant European Union directives.
Electrical Current Range (Off-Hook) 10 mA to100 mA
Tone Level –3 dBm combined(typical)
DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2dB ± 2 dB
On-Hook >3 MΩ Memory Capacity 10 speed dial plus one last numberredial memory
AC Impedance 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4
seconds Rotary Dial (pulse)output
Pulsing Rate 10 pps ±1 pps Hook Flash Duration User programmable, default 600 ms Break/Make Ratio 60 / 40 Automatic Speaker
Shut Off Duration User programmable, default 2minutes
Inter-digit >300 ms Battery 9V alkaline or lithium battery Interval Resistance during Break>100 kΩ
Size and Weight 254 x 96 x 107 mm, 680 g
DTMF (tone) output Tone Frequency Error ±1.5 %maximum
Electrical Return Loss >14 dB (ref 600 Ω) Tone Level –1 dBm combined (typical) DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2 dB ± 2
dB On-Hook >1 MΩ Memory
Capacity 10 speed-dial plus one last number redialmemory
AC Impedance Off-Hook 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4 seconds
Rotary DialOutput
Pulsing Rate 10 pps ±1 pps Hook FlashDuration
User programmable, default 600 ms
Break/Make Ratio 60 / 40 AutomaticSpeaker ShutOff Duration
User programmable, default 5 minutes
Interdigit >300 ms Battery 9V alkaline or lithium battery Interval Resistance During Break >100 kΩ Size and Weight 200 x 68 x 40 mm, 284 g
DTMF Output Tone Frequency Error ±1.5 % maximum
Stock no. Price per OM S$ S$ S$
543-908 unit 1+ 550·00
Stock no. Price per OM S$ S$ S$
543-897 unit 1+ 465·00
2280
www.nguyenxuong.com