New Agilent 7900 ICP-MS Product Information Redefining ICP-MS. Again! February 3, 2015 1
Transcript
Page 1: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

New Agilent 7900ICP-MS Product Information

Redefining ICP-MS.Again!

February 3, 2015

1

Page 2: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Why Change the Market-Leading ICP-MS?Agilent 7700 Series already had the best:

Matrix tolerance (HMI)Interference removal (ORS/He mode)Detection limitsDynamic range (9 orders)

February 3, 2015

2

BM

Page 3: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

How to Improve on the Best ICP-MS?

NEW detector technology for unprecedented 11 orders measurement range and Fast TRA Acquisition at 0.1msec dwell time

NEW Interface & Ion Lens for up to 15x Signal to Noise improvement

NEW ORS4 for ultra fast gas switching in less than 3 seconds

NEW Ultra HMI for analysis of up to 25% NaCl brine solutions without dilutions

February 3, 2015

3

Page 4: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Presenting Agilent’s Game-Changing 7900 ICP-MS

We took the world’s best-selling, highest performing quadrupole ICP-MS, and made it 10x better!

February 3, 2015

4

Page 5: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

7900 ICP-MS Performance Highlights

February 3, 2015

5

JPWB002

Page 6: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Agilent 7900 ICP-MS Key Performance HighlightsRewriting the rules of ICP-MS

February 3, 2015

6

10x better signal to noise (S/N) – even lower detection limits - 2x higher sensitivity, 3-5x lower background

10x higher matrix tolerance – handles even tougher samples - Patented HMI is still unique to Agilent. On the Agilent 7900, the optional UHMI

extends capability to matrix levels of up to 25%

10x wider dynamic range – increases upper measurement limit- 7700’s 9 orders was best in class and the 7900 extends this by up to 11 orders total

measurement range, allowing % levels to be quantified - a first for ICP-MS

30x faster detector –faster transient signal measurement (TRA)- 0.1ms integration time means improved single nanoparticle analysis

Improved productivity -- New ultra fast ORS4 with less than 3 seconds switching time between modes- New ISIS-3 for fast unattended start-up, autotune and sample delivery; full EPA-6020

analysis with 2 gas modes for optimum measurement in <1 minute per sample

Page 7: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Agilent 7900; High Sensitivity TuneCeO/Ce<2.5%

CalibrationLevel Conc. Calc Conc. CPS Det. RSD

1 0 0 1 P 86.62 10 9.89 13676 P 0.63 50 49.984 69112 P 0.94 100 100.019 138295 P 0.4

Uranium calibration in No Gas mode:

High sensitivity1.38 GHz/ppm

Ultra-low background:MDL: 1.3ppq; BEC: 0.48ppq;

February 3, 2015

7

Page 8: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Matrix Tolerance Vastly Superior to Any Other ICP-MSAnalysis of Brine (25% NaCl) with UHMI

No maintenance required for cones and lenses after 3.5 hour stability run. This matrix is even too high for some ICP-OES!

50

60

70

80

90

100

110

120

130

140

150

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

25%

NaC

l + 1

00pp

b

9 Be [ no ]27 Al [ no ]51 V [ no ]51 V [ He ]52 Cr [ no ]52 Cr [ He ]55 Mn [ no ]55 Mn [ He ]56 Fe [ He ]59 Co [ no ]59 Co [ He ]60 Ni [ no ]60 Ni [ He ]63 Cu [ He ]66 Zn [ no ]66 Zn [ He ]68 Zn [ no ]68 Zn [ He ]75 As [ He ]78 Se [ He ]107 Ag [ no ]107 Ag [ He ]111 Cd [ no ]111 Cd [ He ]205 Tl [ no ]205 Tl [ He ]208 Pb [ no ]208 Pb [ He ]238 U [ no ]238 U [ He ]

3.5 hrs Quant Recovery(25% NaCl matrix + 100µg/L spike)

February 3, 2015

8

UHMI DilutionPort

Page 9: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Far Wider Measurement Range Than Any Other ICP-MS11 orders - low and high level calibrations in a single run

Cd (1ppt - 1ppb) and Na (100ppb - 10,000ppm (1%)) in the same run

Concentration range (11 orders) and upper measurement limit (>1%) are at least 10x better than any other ICP-MS

Both calibrations are linear.Total concentration range covered from Cd blank (BEC of <0.1ppt) to Na top standard (1%) is 11 orders

February 3, 2015

9

Page 10: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

7700 H2: 6.0 à 0 mL/min10 sec.

New ICP-MS H2: 6.0à 0 mL/minLess than 2 sec.

Fast Cell Gas Switching – ORS4

February 3, 2015

10

Page 11: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Faster TRA mode for Transient Signal AnalysisRequired for Single Nanoparticle analysisMinimum dwell time is shortened from 3 msec on the 7700 Series to 0.1 msec to allow faster sampling of transient signals.

30 nm Au NP

February 3, 2015

11

Page 12: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

New 7900 ICP-MS; New Technology

February 3, 2015

12

Page 13: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

New Integrated Sample Introduction System (ISIS 3)Fully compliant multi-mode EPA 6020 analysis in <1 minute

7 portvalve (incl. online ISTD port)

Piston pump

3-way valve

February 3, 2015

13

New features in ISIS 3• Close-coupled valve – very

short tube length so minimal stabilization/rinse delay

• Piston pump for faster sample uptake

• 3-way valve to switch between on-line ISTD or tune solution

• ISIS is now compatible with Startup auto-optimization functions and full autotune

Page 14: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

New Agilent 7900 ICP-MS

New UHMIEnables analysis of 25% brine

New Orthogonal Detector system• Higher Sensitivity• Lower Back ground• Extended Upper limitORS4

<3 sec. cell gas switching

New Processor card New Firmware0.1msec dwell time for fast transient and single nanoparticle analysis

PLUSü New Humidifierü Improved Usabilityü 2 Days Installationü Operating Video toolü Remote Advisorü Less MaintenanceNew Productivity option (ISIS 3)

Faster and Fully automated from Start-up

New Plasma interface & Vacuum designEnables higher Sensitivity

New MassHunter 4.1• Improved User Experience• Method automation• New reporting engine

February 3, 2015

14

JPWB002

Page 15: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

New ICP-MS MassHunter Platform

February 3, 2015

15

Page 16: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

MassHunter 4.1: Simpler and More Powerful SoftwareDashboard with Gadgets replaces old mixed UI concept

Gadget icons are “live”; show current status• Hardware on or offline• Plasma on or off• Queue status: idle, paused, running• Most hardware properties and adjustments

grouped under “Settings” menu item

Instrument status monitor (right) can be displayed on top of DA window, to show status and access top level functions without the need to open entire Top Level Application.

February 3, 2015

16

Page 17: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Software so Powerful it Can Write Your Methods!A new era in simple method setup and ease of use

Method Wizard – Develops a complete method in three steps!1. Select pre-set method template and choose matrix level

2. Confirm analytes and internal standards

3. Choose whether to optimize method for speed or DLs

February 3, 2015

17

Page 18: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Remote Monitor App (iOS and Android devices)View instrument status and perform basic system control

An Industry First!

February 3, 2015

18

Page 19: New Agilent 7900 ICP-MS Product Information Redefining ICP … · 2016. 9. 4. · Matrix Tolerance Vastly Superior to Any Other ICP-MS Analysis of Brine (25% NaCl) with UHMINo maintenance

Summary – New Agilent 7900 ICP-MSBetter customer experienceBetter Analytical performance experience§ Ultra high matrix tolerance§ Superior sensitivity and lower background noise§Wider dynamic range§ New Productivity Option (ISIS 3)§ Ultra fast scan speed for Single Nanoparticle analysis