New Data Center and Transport Tom McDermott Fujitsu Network Communications, Inc. October 30, 2014 New Data Center and Transport Interconnect Technology All Rights Reserved, ©2014 Fujitsu Network Communications
Transcript
Page 1: New Data Center and Transport Interconnect Technology

New Data Center and Transport

Tom McDermottFujitsu Network Communications, Inc.October 30, 2014

New Data Center and Transport Interconnect Technology

All Rights Reserved, ©2014 Fujitsu Network Communications

Page 2: New Data Center and Transport Interconnect Technology

Changing Requirements

� Datacenters are expanding in size.� Continued need for 100m / MMF intra-DC connection.� Growing need for 500m~2km / SMF intra-DC connections.� Interest in breakout / fanout capabilities

� Ethernet WAN / Transport Interconnect.� 2km, 10km, 40km – continued need. SMF

� 100GE.� 100GE.� 2nd generation of devices becoming available.� Smaller size, lower cost, lower power.

� 400GE project started.� Intra-DC, Inter-DC, and Metro reach objectives.

� New class of coherent tunable pluggable T/Rs.� Metro reach & compatible with ROADMs� Optical reach over ROADM still TBD.

1All Rights Reserved, ©2014 Fujitsu Network Communications

Page 3: New Data Center and Transport Interconnect Technology

Some Ethernet PMD Nomenclature

� 100GBASE-SR4

100GEShort Reach(100 m) over

MMF

4 optical lanes

� 100GBASE-LR4 = 10 km over duplex SMF

� ER4 = 30 km (40 km with engineering).

� 100GBASE-CR4 = 4 Copper twin-ax cables (each direction) ~ 5m

� 100GBASE-KR4 & KP4 = 4 Copper backplane diff traces (each direction) ~ 1m

2All Rights Reserved, ©2014 Fujitsu Network Communications

Page 4: New Data Center and Transport Interconnect Technology

Breakout / Fanout

� Growing interest in breakout / fanout functionality� Increase density in top of rack (TOR) switches

• Example: a 40GE 40GBASE-SR4 module could be operated in two modes:• 4 x 10GE – QSFP+ physically smaller than 4 separate 1 x 10GE plugs

• 1 x 40GE – data is striped across the 4 lanes.

• Provides high-density 10GE fanout from TOR switch• Provides high-density 10GE fanout from TOR switch

• Fiber-ribbon to duplex fiber conversion is external.

� Recent discussion: 100GE 4-lane module (4 x 25G VCSEL):• 4 x 25GE - An IEEE 802.3 25GE Study Group is underway.

• 1 x 100GE - 802.3bm currently balloting 100GBASE-SR4

3All Rights Reserved, ©2014 Fujitsu Network Communications

Passive

MMFribbon

Page 5: New Data Center and Transport Interconnect Technology

Density Evolution 10GE � 100GE2002 � 2014

Front-PanelBandwidth

Density(GB per 10

mm)

58.4

73

CFP4

QSFP28

CXP (MMF)37.7

(2014)

(2008-2010)

10G 40G 100G

XFPSFP+

XFP4 xSFP+

4

5.457.30

29.2

Port Bandwidth

4 x

QSFP (MMF) QSFP+ (MMF)

CFP13.7

CFP227.4

CXP (MMF)37.7

CPAK

All Rights Reserved, ©2014 Fujitsu Network Communications

(2002)

(2006) (2013)

(2010)

(2012)

(2012)

(x 4)

(x 4)

Page 6: New Data Center and Transport Interconnect Technology

100GE Package Evolution

CFP

CFP

CFP

CFP

CFP

2C

FP

2C

FP

2C

FP

2

100G

Today: CFP:

10x10MSA,

100GBASE-LR4

100GBASE-ER4

100GBASE-SR10

Future: Digital DWDM

Today: CFP2:

100GBASE-LR4,

100GBASE-ER4

10x10MSA? (v2),

Future: Analog Coherent

DWDM

10 x 10G Digital Electrical I/O +

QSFP

28

QSFP

28

QSFP

28

QSFP

28 C

FP

4C

FP

4C

FP

4C

FP

4

CFP

2C

FP

2C

FP

2C

FP

2

5

Future: Digital DWDM

Coherent

10 x 10G Digital Electrical I/O

10 x 10G Digital Electrical I/O +

4 x 25G Digital Electrical I/O +

4 x 25G Analog I/O

QSFP28: 100GBASE-SR4,

100GBASE-CR4 (copper)

4 x 25G Digital Electrical I/O

All Rights Reserved, ©2014 Fujitsu Network Communications

Page 7: New Data Center and Transport Interconnect Technology

CFP / CFP2 / CFP4 Client Devices

10:4Gearbox+ Retime

4 x Driver

4 x Receiver

4 x TOSA+ WDM

WDM +4 x ROSA

Optical I/O

4 x Retime +

10 x

10G

Dig

ital

4 x

25G

Dig

ital

CFP Client~24w

Gen

1

6All Rights Reserved, ©2014 Fujitsu Network Communications

4 x Retime + Driver

4 x Receiver+ Retime

IntegratedMultidevice

TOSA+ROSA+ WDMs

Optical I/O

4 x

25G

Dig

ital

(10x10MSA version is 10 parallel channels at 10G)

CFP2 Client8~12w

4 x

25G

Ana

log

CFP4 or QSFP28 Client

4 x VCSEL4 x PIN

~4.5w

4 x Retime + Driver

4 x Receiver+ Retime

Optical I/O 100m

Gen

2F

utur

e

Page 8: New Data Center and Transport Interconnect Technology

100GBASE-SR10 vs. 100GBASE-SR4Generation 1, CFP form factor : Generation 2, QSFP28 form factor

10 x retime &VCSELdriver

10 E

lect

rical

Inte

rfac

e

10 fiber MMF

MP

O o

ptic

al c

onne

ctor

Generation 1100GBASE-SR10

10G / lane

7All Rights Reserved, ©2014 Fujitsu Network Communications

10 x PINreceive amp

& retime

CA

UI-

10 E

lect

rical

Inte

rfac

e

10 fiber MMF

MP

O o

ptic

al c

onne

ctor

CFP

4 x retime &VCSELdriver

4 x PINreceive amp

& retime

CA

UI-

4 E

lect

rical

Inte

rfac

e

4 fiber MMF

4 fiber MMFM

PO

opt

ical

con

nect

or

QSFP28

10G / lane

Generation 2100GBASE-SR4

25G / lane

Page 9: New Data Center and Transport Interconnect Technology

QSFP28 Client Device

� IEEE 802.3bm considered retimer-less interface for 20m (resulting in ~1.5w QSFP28), but rejected.� 100m MMF requires retimer.� 20m market was too small to develop independent interface

type from 100m.� Might be used in future very short reach applications.

� Proprietary Active Optical Cable interfaces adopted QSFP28 / 1.5w form factor.

8All Rights Reserved, ©2014 Fujitsu Network Communications

Optical I/O

4 x

25G

Ana

log

QSFP28 Client

4 x Driver4 x VCSEL

4 x PIN

4 x Lim Amp~1.5w

Page 10: New Data Center and Transport Interconnect Technology

Package Trends – 100GE Client Optics

� 1st generation: CFP: for MMF and SMF (actual)

� 2nd generation: CFP2, CPAK (actual)

� 3rd generation: CFP4, QSFP28 (forecast, actual)

9All Rights Reserved, ©2014 Fujitsu Network Communications

QSFP28CFP CFP2 CFP4

Page 11: New Data Center and Transport Interconnect Technology

Some 400GE Adopted ObjectivesSome Initial Ideas� Support a BER of better than or equal to 10-13 at the MAC/PLS service

interface (or the frame loss ratio equivalent)� Provide appropriate support for OTN� Specify optional Energy Efficient Ethernet (EEE) capability for 400 Gb/s

PHYs� Provide physical layer specifications which support link distances of:

� At least 100 m over MMF� At least 500 m over SMF� At least 500 m over SMF� At least 2 km over SMF� At least 10 km over SMF

� 25G x 16 VCSEL looks promising for MMF…� Small package (CDFP?), new 16-position MMF MT/MP connector.� Potential for very high density and lower cost.

� Several formats including 4λ-DMT and 8λ-PAM4 being studied for duplex SMF.

10All Rights Reserved, ©2014 Fujitsu Network Communications

Page 12: New Data Center and Transport Interconnect Technology

Form Factor Evolution 400GE Client

CD

P

CD

P2

Ref: oif2012.346.02

Gen 1: CDP Client:400GBASE-???

16 x 25G Digital Electrical I/O

Gen 2: CDP2 Client400GBASE-???

8 x 50G Digital Electrical I/O

16x25Gelectrical

lanes

8x50Gelectrical

lanes

CD

P4

4x100Gelectricallanes ??

11

XAUI = 10GEXLAUI = 40GECAUI = 100GE

CDAUI = 400GE

Far Future: CDP4 Client: 400GBASE-???

Are electrical lanes practical at 100G?

All Rights Reserved, ©2014 Fujitsu Network Communications

Note: originally called CDFP in the OIF presentation. Renamed to CDP.

Page 13: New Data Center and Transport Interconnect Technology

CDFP MSA (for 400GE) March 10, 2014 MSA Rev 1.0

� Provides 16 x 25G electrical interface.

� Optimized for 16-wide VCSEL based MMF. TIA concurrently working on standard for 2 x 16 MMF fiber ribbon and MTO/MTP MMF connector.

� Could be called 400GBASE-SR16 if IEEE standardized in 2017.� Desire by some in IEEE to have a 4 x 100GBASE-SR4 breakout mode of operation.

� Card cage is small, but cage + plug in roughly the same size as 4 x QSFP28

12All Rights Reserved, ©2014 Fujitsu Network Communications

Page 14: New Data Center and Transport Interconnect Technology

1 Terabit Ethernet

� IEEE elected to work on 400GE as opposed to 1TE due to significant technical issues.� Very small size, low power, low cost and high production volume are

key requirements for intra-datacenter optics (TOR Ethernet switch interconnect).

� Extrapolating current technology: 40 channels x 25G VCSEL. � Would require 40-wide MMF fiber ribbon x 2 (80 total fibers).� Electrical interconnect to the package would be massive.� Electrical interconnect to the package would be massive.

� Faster electrical signaling speeds and multi-level modulation may be possibilities.� Not ready for the IEEE application.

� Proposals for DMT and PAM-4 technology for 400GE.� 500m – 10km duplex SMF.� Future: Might form basis for 1TE Duplex SMF Ethernet client

interconnect.

13All Rights Reserved, ©2014 Fujitsu Network Communications

Page 15: New Data Center and Transport Interconnect Technology

Coherent DWDM PackagingNetwork Optics

� DWDM Coherent 100G optics moving towards CFP2 form factor.

� Two approaches:� Digital Interface to Optics

• Places DSP inside the optics package.• Pros: well-quantified optical performance.• Pros: well-quantified optical performance.• Cons: DSP power consumption makes thermal issues extremely

challenging.

� Analog Interface to Optics.• DSP is outside the optics package.• Pros: multivendor optical sourcing, low cost, thermal management fits

CFP2 package well. CFP4 may become practical later.• Cons: PC board layout and DSP placement may impact optical span

performance in strong or weak ways (unknown at this time).

14All Rights Reserved, ©2014 Fujitsu Network Communications

Page 16: New Data Center and Transport Interconnect Technology

CFP2 Analog DWDM Coherent Module

4 x Driver

4 x TIA PBS + Coherent QuadCombiner + 8 x PIN

DWDMCoherent

Optical I/O

LaserLocal Osc

DP-QPSKModulator + PBC

CFP2 Optical Package

DSPASIC

15All Rights Reserved, ©2014 Fujitsu Network Communications

4 x ~32G Analog

• Analog interface and copper traces between DSP and CFP2 optics will impact the span reach and optical performance.

• Skew, reflection, attenuation, crosstalk.• Quantification of the impact requires actual DSP, PC Board, and

optical CFP2 modules, and characterization.

Page 17: New Data Center and Transport Interconnect Technology

CFP2 Digital DWDM Coherent Module

4 x Driver

4 x TIA PBS + Coherent QuadCombiner + 8 x PIN

DWDMCoherent

Optical I/O

CA

UI-

4 In

terf

ace

LaserLocal Osc

DP-QPSKModulator + PBC

CFP Optical Package

DSPASIC

16All Rights Reserved, ©2014 Fujitsu Network Communications

• Standard CAUI-4 interface and copper traces between Host and Module.• Optical span performance not dependent on host.

• CFP package currently required due to high power dissipation.

Page 18: New Data Center and Transport Interconnect Technology

Analog CFP2 IssuesDigital CFP Issues� Interface to Analog CFP2 DWDM Coherent transceiver.

� DSP is external to the optics package.� Copper traces connect analog I/O from DSP to Optics.� Signaling rate is about 32 Gbps. Digitizing rate of DSP ADC is about 64

Gsps.� Future generations (class 2, 3) planned to additionally support 16QAM.

� Analog interface, DSP, copper traces, optical module all have an impact on the optical span performance.impact on the optical span performance.� Too early to tell how tightly constrained the optical performance will be.

• Performance may be weakly or strongly impacted by PCB motherboard, DSP, copper traces, and/or optics module changes.

• Might be addressable with conservative design rules.• Might be addressable by complete chain characterization (but this can get

complex). • Optics + DSP + PCB motherboard to determine performance.

� Digital module is large due to high power DSP inside optical envelope.

� Limited supply base for digital version.

17All Rights Reserved, ©2014 Fujitsu Network Communications