8/11/2019 Nortel Counters Description http://slidepdf.com/reader/full/nortel-counters-description 1/1041 Wireless Service Provider Solutions Observation Counter Dictionary PE/DCL/DD/0125 15.107/EN Standard July 2005 411--9001--125
Transcript
  • 8/11/2019 Nortel Counters Description

    1/1041

    Wireless Service Provider Solutions

    Observation Counter Dictionary

    PE/DCL/DD/0125 15.107/EN Standard July 2005411--9001--125

  • 8/11/2019 Nortel Counters Description

    2/1041

    Copyright 2000--2005 Nortel Networks

  • 8/11/2019 Nortel Counters Description

    3/1041

    < 1 2 5 > : O bs er va ti on C o un te r D i ct i on ar y

    Wireless Service Provider Solutions

    Observation Counter DictionaryDocument number: PE/DCL/DD/0125

    411--9001--125

    Document status: StandardDocument issue: 15.107/ENProduct release: GSM/BSS V15.1Date: July 2005

    Copyright 2000--2005 Nortel Networks, All Rights Reserved

    Originated in France

    NORTEL NETWORKS CONFIDENTIAL:

    The information contained in this document is the property of Nortel Networks. Except as specifically authorized inwriting by Nortel Networks, the holder of this document shall keep the information contained herein confidential andshall protect same in whole or in part from disclosure and dissemination to third parties and use for evaluation,operation and maintenance purposes only.

    You may not reproduce, represent, or download through any means, the information contained herein in any way or inany form without prior written consent of Nortel Networks.

    The following are trademarks of Nortel Networks: *NORTEL NETWORKS, the NORTEL NETWORKS corporate logo,

    the NORTEL Globemark, UNIFIED NETWORKS, S2000, S4000, S8000. GSM is a trademark of France Telecom.

    All other brand and product names are trademarks or registered trademarks of their respective holders.

  • 8/11/2019 Nortel Counters Description

    4/1041

    Copyright 2000--2005 Nortel Networks

  • 8/11/2019 Nortel Counters Description

    5/1041

    Publication HistoryNortel Networks Confidential iii

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    PUBLICATION HISTORY

    System release:GSM/BSS V15.1

    July 2005

    I s s u e 1 5 . 1 0 7 / E N S t a n d a r d

    C R Q 0 1 1 66 0 7 2: m o d i f ie d t h e Q 3 n a m e o f C 1 7 20 t o r a d i oF r a m eU I R e ce i v ed ( f r o mabisTrauFrameUIReceived).

    June 2005

    I s s u e 1 5 . 1 0 6 / E N S t a n d a r d

    U p da t ed t h e d e sc r i pt i on s o f t h e c o un t er s p c uE d ge T dm a 15 1 08 s0 ( 1 51 0 8/ 0 ) a n dp c u E d g e T d m a 1 5 1 0 9 s 0 ( 1 5 1 0 9 / 0 ) i n s e c t i o n 2 . 9 .

    U p da t ed f o r F e at u r e I d 2 9 48 5 V1 5 .1 . 1 n e w c ou n te r s i n tr o du ct i on i n V 1 5. 1 t o a v oi di n t e r f a c e d i s r u p t i o n . T h e c o u n t e r s 1 5 0 8 , 1 9 3 5 , 1 9 3 6 , 1 9 3 7 , 1 9 3 8 , 1 9 3 9 , a n d 2 0 9 6a r e a l l r e s e r v e d f o r f u t u r e u s e . S e e a l s o t h e P u b l i c a t i o n H i s t o r y f o r A p r i l 2 0 0 5 f o rI s s u e 1 5 . 1 0 3 / E N P r e l i m i n a r y o f t h i s d o c u m e n t .

    U p d a t e d f o r F e a t u r e I d 2 8 4 2 2 e M L P P s u p p o r t o n a G S M n e t w o r k .

    C R Q 011 57 43 0: m ov ed t he c ou nt er s 1 08 6, 1 08 7, a nd 1 08 8 f r om s ec ti on 2 .4 t os e c t i o n 2 . 2 .

    June 2005

    I s s u e 1 5 . 1 0 5 / E N S t a n d a r d

    CR Q01125865:

    u p da t ed t h e f o r m u la s f o r t h e s yn t he t ic c o un t er s i n s ec t io n 2 . 6 ( b y a d di n g t h eg r e a t e r p e r c t e r m w h e r e r e q u i r e d ) .

    r e i nt r o du c ed s i x s yn t he t ic c o un t er s i n s ec t io n 2 . 6 ( 8 80 3 , 8 8 13 , 9 5 10 , 9 5 11 , 9 5 12 ,9600)

    R e m o v e d i n f o r m a t i o n o n B S C 6 0 0 0 d u e t o E O L .

    April 2005

    I s s u e 1 5 . 1 0 4 / E N S t a n d a r d

    S y n c h r o n i z e d w i t h 1 5 . 0 . 1 S t a n d a r d .

  • 8/11/2019 Nortel Counters Description

    6/1041

    Publication History Nortel Networks Confidentialiv

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    April 2005

    I s s u e 1 5 . 1 0 3 / E N P r e l i m i n a r y

    C R Q 01 08 16 55 : u pd at ed i nt er -- B SS h an do ve r D at a F lo w D ia gr am i n s ec ti on1 . 2 . 4 . 5, a n d i n t e r -- C E L L i n t r a -- B S S D a t a F l o w D i a gr a m i n s e ct i o n 1 . 2 . 4 .4

    V 1 5 . 1 . 1 c o u n t e r s a d d e d , a n d t h e i r v a l u e i s s e t t o 0 i n V 1 5 . 1 :

    F e a t u r e I d 1 5 3 4 7 N e t w o r k s y n c h r o n i z a t i o n : a d d e d c o u n t e r 2 0 9 6

    F ea t ur e I d 2 26 8 8 A M R b a se d o n t r a ff i c : a d de d c ou n te r s 1 93 5 , 1 9 36 , 1 9 37 , 1 9 38 ,1939

    F ea tu re I d 2 93 12 P ag in g c ap ac it y i nc re as e -- U I m od e -- B SC 3 00 0: a dd edc o u n t e r 1 5 0 8

    Added the following counters: 1828/0, 1828/1, 1829/0, 1934/0, 2002/0, 2002/1,2 0 0 2 / 2 , 2 0 0 3 / 0

    I n t e g r a t e d c o m m e n t s f r o m V 1 5 . 1 D r a f t r e v i e w

    U p d a t e d c o u n t e r c o n f i g u r a t i o n l i s t i n s e c t i o n 1 . 4 . 1

    R e pl a ce d t r a ns ce i ve r Z on e /b t s t o b t s/ t r an sc e iv e rZ o ne i n o b je ct f i e ld o f c ou n te rdescriptions

    Index clean--up (phase 2)

    March 2005

    I s s u e 1 5 . 1 0 2 / E N D r a f t

    S y n c h r o n i z e d w i t h V 1 5 . 1 R S t a n d a r d

    I n t e g r a t e d l a t e r e v i e w c o m m e n t s f r o m V 1 5 . 0 . 1 P r e l i m i n a r y

    Index clean--up (phase 1)

    February 2005

    I s s u e 1 5 . 1 0 1 / E N D r a f t

    S y n c h r o n i z e d w i t h V 1 5 . 0 . 1 P r e l i m i n a r y

    January 2005

    I s s u e 1 5 . 1 0 0 / E N D r a f t

    F e at u re I d 1 3 91 3 A S CI E v ol u ti o ns : u p da t ed c ou n te r s 11 9 3/ 8 , 1 7 22 / 0, 1 7 22 / 1,2 0 5 2 / 0 , 2 0 5 3 / 0

  • 8/11/2019 Nortel Counters Description

    7/1041

  • 8/11/2019 Nortel Counters Description

    8/1041

    Publication History Nortel Networks Confidentialvi

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    F e a t u r e I d 2 0 5 7 1 : a d d e d s e c t i o n 1 . 2 . 1 1 f o r A S C I . A d d e d c o u n t e r 1 1 9 3 / 8 i n s e v e r a l

    places.

    F ea tu re I d 2 30 03 : a dd ed s ec ti on 1 .2 .2 .2 f or O TD I. u pd at ed c ou nt er s 1 72 2/ 0,1 7 2 2 / 1 , 1 7 2 3 , 1 7 2 4 a n d 1 7 2 5

    F e a t u r e I d 2 3 7 1 7 : a d d e d s e c t i o n 1 . 1 . 4 f o r M o b i l i t y C l a s s S e n s i t i v i t y C o u n t e r s

    F e a t u r e I d 2 4 4 6 2 : a d d e d D a t a F l o w D i a g r a m i n s e c t i o n 1 . 2 . 1 1

    F e a t u r e I d 2 6 3 1 0 : u p d a t e d s e c t i o n 1 . 1 . 1 . 3 . A d d e d s e c t i o n 1 . 1 . 1 . 5

    F e a t u r e I d 2 6 4 7 9 : a d d e d s e c t i o n 1 . 1 . 2 . 4 f o r B S C c o u n t e r l i s t s i z e

    C R Q 0 0 8 1 4 6 5 2 : a d d e d c o u n t e r s 1 8 2 1 t o 1 8 2 7 i n s e c t i o n 2 . 2

    C R Q 0 09 3 42 5 4: u p da t ed c o un t er s 1 8 12 , 1 8 13 , 1 0 57 , 1 7 00 , 1 8 10 , 1 611 , 1 7 46 i ns e c t i o n 2 . 2

    U p d a t e d A p p e n d i x f o r V 1 5 . 1 R c o u n t e r e v o l u t i o n s

    R e o r g a n i z e d A p p e n d i x f o r V 1 5 . x e v o l u t i o n s

  • 8/11/2019 Nortel Counters Description

    9/1041

    Publication HistoryNortel Networks Confidential vii

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    SYSTEM RELEASE: GSM/BSS V15.0

    October 2004

    I s su e 1 5 .2 5 /E N S t an d ar d -- C R Q 0 09 5 62 4 4 r e mo v e C o un t er s 3 00 2 , 3 0 03 , 3 0 06 , a n d3 0 0 7 f o r c u s t o m e r c l a r i f i c a t i o n .

    I s s u e 1 5 . 2 4 / E N S t a n d a r d

    Misc cleanups

    September 2004

    I s s u e 1 5 . 2 3 / E N S t a n d a r d

    August 2004

    I s s u e 1 5 . 2 2 / E N P r e l i m i n a r y

    C R Q 0 0 96 4 5 02 -- u p d at e d c o u nt e r s 1 16 4 / 2 8 a n d 1 16 4 / 3 2.

    R e m o v e d p a r e n s f r o m t h r e e c o u n t e r l o c a t o r n a m e s s o W o r l d V i e w w i l l w o r k .

    August 2004

    I s s u e 1 5 . 2 1 / E N P r e l i m i n a r y

    C R Q 0 0 95 6 8 90 -- u p d at e d c o u nt e r 1 8 0 3/ 4 .

    I s s u e 1 5 . 2 0 / E N P r e l i m i n a r y

    C R Q 0 09 56 2 44 -- u p da t ed n o te s ( S t at i ng n ot i m pl e me n te d f o r v 1 4. 3 o r v 1 5) o nc o u n t e r s 3 0 0 2 , 3 0 0 3 , 3 0 0 6 , a n d 3 0 0 7 .

    August 2004

    I s s u e 1 5 . 1 9 / E N P r e l i m i n a r y

    C R Q 0 0 95 3 8 89 -- r e m o ve d c o u nt e r 1 16 3 / 29 .

    July 2004

    I s s u e 1 5 . 1 8 / E N P r e l i m i n a r y

    C R Q 0 09 5 52 4 6 -- r e mo v ed t h e s t ri n g Tc h f r o m t h e c o un t er n a me s f o r c ou n te r s1 0 6 5 / 1 , 1 0 6 6 / 1 , 1 0 6 7 / 1 , a n d 1 0 6 8 / 1 .

    I s s u e 1 5 . 1 7 / E N P r e l i m i n a r y

    P r e p a r a t i o n f o r H e l m s m a n r e l e a s e

    July 2004

    I s s u e 1 5 . 1 6 / E N P r e l i m i n a r y

    C R Q 0 0 94 1 5 08 -- m u l t i pl e c h a ng e s a n d a d d i ti o n s f r o m c o m me n t s C R .

  • 8/11/2019 Nortel Counters Description

    10/1041

    Publication History Nortel Networks Confidentialviii

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    July 2004

    I s s u e 1 5 . 1 5 / E N P r e l i m i n a r y

    C R Q 0 0 93 7 1 50 -- 0 2 -- I n c o r po r a t ed C R c o m me n t s t o c o r r e ct F o r m ul a s a n d u p d at e dc o u n t e r s i n S e c t i o n 1 t a b l e s .

    I s s u e 1 5 . 1 4 / E N P r e l i m i n a r y

    C R Q 0 0 94 0 9 52 -- I n c o r po r a t e d C R c o m me n t s f o r c o u nt e r n u m be r 1 5 1 93 / 0 .

    I s s u e 1 5 . 1 3 / E N P r e l i m i n a r y

    C R Q 0 08 6 24 2 2 -- A d de d c ou n te r s 3 0 04 / 1 a nd 3 0 04 / 2 i n C h ap t er s 1 a nd 2 . A l sop l a c e d t h e m i n t o t h e a p p r o p r i a t e t a b l e s .

    I s s u e 1 5 . 1 2 / E N P r e l i m i n a r y

    Added counters 1138/2/3/8 in Chapters 1, 2, and Appendix A for Feature 27215

    July 2004

    I s s u e 1 5 . 1 1 / E N P r e l i m i n a r y

    R e v ie w e r r e m a r ks -- a d d in g c o u nt e r s t o A p p en d i x t a b l es .

    June 2004

    I s s u e 1 5 . 1 0 / E N P r e l i m i n a r y

    C R Q 0 0 90 3 3 47 -- r e n a me c o u nt e r s 1 7 6 8 / 0 , / 1 , 1 7 6 9/ 0 , / 1 , 1 7 7 2/ 0 , / 1 , a n d 1 7 7 3 / 0 ,/1, by replacing the word cell with BSS.

    C o r r e c t i n g l o c a t o r t a g s , m i s s i n g c o u n t e r s , a n d s p e l l i n g e r r o r s f r o m s o u r c e a n d l a s tload.

    C R Q 0 09 1 87 4 7 -- R e mo v ed c ou n te r 1 0 52 / 0, 1 0 52 / 1, a n d 1 0 52 / 2, r e pl a ce d w i thc o u n t e r 1 6 1 1 / 0 a n d 1 6 1 1 / 1 .

    June 2004

    I s s u e 1 5 . 0 8 / E N P r e l i m i n a r y

    From reviewers remarks:R em o ve d p ar a 1 . 5. 4 . 1 O RT & I P O s yn t he t ic c ou n te r s a n d t a bl e . I PO s yn t he t icc o u n t e r s n o m o r e e x i s t s i n c e V 1 1 . . . i f s a m e c h a p t e r a l r e a d y e x i s t f o r V 1 4 N T P s , i ti s a m i s t a k e .

  • 8/11/2019 Nortel Counters Description

    11/1041

    Publication HistoryNortel Networks Confidential ix

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    May 2004

    I s s u e 1 5 . 0 7 / E N P r e l i m i n a r y

    I n c o r p o r a t e d C o u n t e r n a m e c h a n g e s 1 7 7 2 / 0 , 1 7 7 2 / 1 , a n d 1 7 7 3 / 0 , 1 7 7 3 / 1 r e c e i v e df r o m e m a i l r e m a r k s .

    I nc or po r at ed C ou nt er d ef i ni t io ns 1 51 32 /0 t hr u 1 51 89 /0 r ec ei ve d f r om e ma ilremarks.

    I n c o r p o r a t e d C R Q 0 0 8 7 3 1 6 1 u p d a t e d c o u n t e r s 1 6 1 1 / 3 , 1 6 1 2 / 0 , a n d 1 6 1 2 / 1 .

    Added Feature 26797 -- Directed Retry Counters

    CR Q00184739 -- 05 -- Counter 1721 name changed f r om

    Erroneous_Frame_Number to ECU_Activation.

    April 2004

    I s s u e 1 5 . 0 6 / E N P r e l i m i n a r y

    I n c o r p o r a t e d S M E r e v i e w c o m m e n t s .

    March 2004

    I s s u e 1 5 . 0 5 / E N P r e l i m i n a r y

    F o r C R Q 0 0 8 3 6 6 6 6 , d e l e t e d c o u n t e r s 3 0 0 0 / 1 , 3 0 0 1 / 1 , 3 0 0 4 / 2 a n d 3 0 0 5 / 1 .

    March 2004

    I s s u e 1 5 . 0 4 / E N P r e l i m i n a r y

    U p d a t e f o r r e v i e w c o m m e n t s .

    F o r C R Q 00 8 35 9 72 -- 0 1 , d e le t ed 1 83 5 c o un t er s c ar d Sy n th L oa d Bs cb < x> a n dcardSynthLoadTscb.

    March 2004

    I s s u e 1 5 . 0 3 / E N P r e l i m i n a r y

    For CR Q00835972 -- 01, deleted inf or mati on concer ni ng the 1835cardSynthLoadBscbMoy/Max counters.

    F o r C R Q 0 07 9 27 5 8, c h an g ed t h e d e sc r ip t io n o f S D CC H a n d c ha n ge d t h e f u nc t io n so f c o u n t e r n u m b e r s 1 6 0 9 / 2 a n d 1 6 1 1 / 2 .

    F o r C R Q 0 0 8 4 1 8 1 2

    Modified features:

    1 5 0 1 5 G P R S T B F e s t a b l i s h m e n t i m p r o v e m e n t : o n e p h a s e a c c e s s

    N e w f e a t u r e s :

    2 0 2 1 9 E D G E l i n k a d a p t a t i o n

  • 8/11/2019 Nortel Counters Description

    12/1041

    Publication History Nortel Networks Confidentialx

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    January 2004

    I s s u e 1 5 . 0 2 / E N D r a f t

    F o r C R Q 0 0 70 7 4 42 -- 0 1 , i n c o r po r a t ed m i n or c h a ng e s.

    December 2003

    I s s u e 1 5 . 0 1 / E N D r a f tM o d i f i e d f e a t u r e s :

    1 9 1 7 4 E D G E D y n a m i c A B I S a n d A G P R S b a c k h a u l

    2 0 2 3 1 E D G E T r a f f i c M a n a g e m e n t

    2 2 4 6 3 W P S B S S 2 G a n d E 3 q u e u i n g m e c h a n i s m e n h a n c e m e n t

    2 2 4 6 4 W P S B S S 2 G a n d E 3 a c c e s s c l a s s b a r r i n g w i t h c l a s s p e r i o d i c r o t a t i o n

    2 2 4 6 5 W P S B S S 2 G a n d E 3 p u b l i c a c c e s s b a n d w i d t h p r o t e c t i o n

    SYSTEM RELEASE: GSM/BSS V14.3

    October 2003

    I s s u e 1 4 . 1 1 / E N S t a n d a r d

    August 2003

    I s s u e 1 4 . 1 0 / E N P r e l i m i n a r y

    Added AMR V14 counters in appendix A.

    Added new BSC 2G V14 counters and BSCe3 V14 counters in Appendix A.

    C h e c k e d t h e A M R a n d e 3 c o u n t e r s .

    Added the following e3 counter description: 3002, 3003, 3006, 3007, 1507/0,1 5 0 7 / 1 , 1 5 0 7 / 2 , 1 5 0 7 / 3 , 1 5 0 7 / 4 .

    Added the following AMR counter description: 1197/2, 1197/3, 1780/1, 1780/2,1 9 0 6 / 0 , 1 9 1 7 / 1 , 1 9 2 9 / 1 .

    M o d i f i e d t h e f o l l o w i n g c o u n t e r d e s c r i p t i o n : 1 7 8 0 / 0 , 1 9 1 7 / 0 , 1 9 2 9 / 0 .

    Added the following V14.3 counter description: 1816/0, 1817/0, 1818/0, 1819/0,1820/0.

    M o di f i ed t h e n a me o f t h e f o ll o wi n g c o un t er s : 1 8 03 / 0, 1 8 03 / 1, 1 8 03 / 2, 1 8 03 / 3,1803/4,

  • 8/11/2019 Nortel Counters Description

    13/1041

  • 8/11/2019 Nortel Counters Description

    14/1041

    Publication History Nortel Networks Confidentialxii

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    December 2002

    I s s u e 1 4 . 0 6 / E N P r e l i m i n a r y

    U p d a t e f o r V 1 4 . 3 s y s t e m r e l e a s e ( B S S )

    I P O c o u n t e r s i n p a r a g r a p h 1 . 5 . 4 . 1 h a v e b e e n r e m o v e d

    M e n t i o n s t o i n s t r u m e n t p a n e l i n p a r a g r a p h 1 . 7 . 1 a n d 1 . 7 . 3 h a v e b e e n r e m o v e d

    O R T h a s b e e n c h a n g e d i n I P O f o r t h e c o u n t e r n o . 9 6 0 0 i n p a r a g r a p h A 3 . 1

    November 2002

    I s s u e 1 4 . 0 4 / E N P r e l i m i n a r y

    U p d a t e f o r V 1 4 . 3 s y s t e m r e l e a s e ( B S S )

    T h e f o l l o w i n g f e a t u r e s h a v e b e e n t a k e n i n t o a c c o u n t :

    B S C e 3 c o u n t e r s ( 2 2 5 2 6 )

    AR 1209--6 BSC e3 observation counters (22673)

    T h e f o l l o w i n g m o d i f i c a t i o n s h a v e b e e n m a d e t o t h e m a n u a l :

    c h a p t e r 1 I n t r o d u c t i o n :

    T h e f o l l o w i ng c o u n t e r s h a v e b e e n a d d ed :

    a l l 1 9x x c ou nt er s ( r ef er t o p ar ag ra ph 1 .5 .2 , 1 .5 .3 a nd 1 .5 .4 .1 -- R awp e r m a n e n t c o u n t e r s s e t t a b l e b y t h e o p e r a t o r ( A M R ) ,

    C h a p t e r 2 C o u n t e r s D e s c r i p t i o n :

    T h e f o l l o w i ng c o u n t e r s h a v e b e e n a d d ed :

    a l l 1 9 x x c o u nt e r s ( r e f e r t o p a r a gr a p h 2 . 2 . 2 -- R a w p e r m an e n t B S S c o u n t e r s(AMR).

    SYSTEM RELEASE: GSM/BSS V13

    October 2002

    I s s u e 1 3 . 0 7 / E N S t a n d a r d

    T h e f o l l o w i n g m o d i f i c a t i o n s h a v e b e e n m a d e t o t h e m a n u a l

    Added screenings to the counter 1104 (1104/0 and 1104/1)

    Added screenings to the counter 1106 (1106/2 and 1104/3)

    August 2002

    I s s u e 1 3 . 0 6 / E N S t a n d a r d

  • 8/11/2019 Nortel Counters Description

    15/1041

    Publication HistoryNortel Networks Confidential xiii

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    M i n o r e d i t o r i a l u p d a t e

    I s s u e 1 3 . 0 5 / E N P r e l i m i n a r y

    T h e f o l l o w i n g m o d i f i c a t i o n s h a v e b e e n m a d e t o t h e m a n u a l :

    C h a p t e r 1 I n t r o d u c t i o n

    M o d if i e d t h e f o l l o w i n g P C U S N D a t a F l o w D i a g r a m s ( p a r a gr a p h 1 . 2 . 9 ) :

    B VC f l o w c o n tr o l a nd M S f l o w c o n tr o l m e c h an i sm s

    D i sc ar d o f L L C P D Us

    E st ab li sh me nt o f a n U L T BF i n t wo p ha se s a cc es s w it h f i rs t p ha se i n

    CCCH E s ta b li s hm e nt o f a n U L T B F d u ri n g D L T B F

    N o rm a l U L T B F r e l ea se

    A b no r ma l r e l e as e o f a n U L T B F d u e t o n o n p r o gr e ss i on o f V ( Q )

    A bn or m al r el ea se o f a n U L T BF d ue t o n on p r og re ss io n o f V (Q ) d ur i ng f u lld u p l e x t r a n s f e r i n t h e c a s e t h a t t h e D L T B F i s a l s o r e l e a s e d

    N on r e sp on se f r om t he m ob il e s ta ti on a ft er N 31 01 s ch ed ul ed b lo ck s( m e a n s w i t h U S F s e t i n d o w n l i n k )

    N on r e sp on se f r om t he m ob il e s ta ti on a ft er N 31 01 s ch ed ul ed b lo ck s( m e a n s w i t h U S F s e t i n d o w n l i n k ) d u r i n g f u l l d u p l e x t r a n s f e r , i n t h e c a s et h a t t h e D L T B F i s a l s o r e l e a s e d

    N o n r e sp o ns e f r o m t h e m o b i le a f t er U P _N A SS I GN MA X P a ck e t U p l i nkAssignment messages

    N on p ro gr es si on f r om t he m ob il e a f te r U P_ NA SS IG NM AX P ac ke tU p l i n k A s s i g n m e n t m e s s a g e s d u r i n g f u l l d u p l e x t r a n s f e r , i n t h e c a s e t h a tt h e D L T B F i s a l s o r e l e a s e d

    N o n r e s p on s e f r o m t h e m o b i l e a f t e r N 3 1 03 P a c ke t U p l i n k A c k / N a ck s e n twith FAI=1

    N o n r e s p on s e f r o m t h e m o b i l e a f t e r N 3 1 03 P a c ke t U p l i n k A c k / N a ck s e n twith FAI=1 during full transfer, in the case that the DL TBF is also released

    P a gi n g p r oc ed u re i n it i at e d b y t h e n e tw o rk f o r d o wn l i nk p ac k et t r an sf e rt o w a r d s a M S i n s t a n d b y s t a t e

    D o w n li n k e s t a bl i s h me n t t o w a r d s a m o b i l e i n R e ad y S t a t e a n d P a c ke t I d l eMode

    E s ta b li s hm e nt w i t h P a ck e t D o wn l in k A ss i gn m en t a nd P a ck et Ti m es l otReconfigure

    N o rm a l D L T B F R e l ea se

  • 8/11/2019 Nortel Counters Description

    16/1041

    Publication History Nortel Networks Confidentialxiv

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    A b no r ma l r e l e as e o f a n D L T B F d u e t o n o n p r o gr e ss i on o f V ( A )

    A bn or m al r e le as e o f a n D L T BF d ue t o n on p ro gr es si on o f V ( A) d ur i ng f ul ld u p l e x t r a n s f e r , i n t h e c a s e t h a t t h e U L T B F i s a l s o r e l e a s e d

    N o n r e s po n se f r o m t h e m o bi l e a f t e r N 3 10 5 d o w n li n k d a t a w i t h S / P= 1

    N on r es po ns e f r om t he m ob il e a ft er N 31 05 d ow nl in k d at a w it h S /P =1d u r i n g f u l l d u p l e x t r a n s f e r , i n t h e c a s e t h a t t h e U L T B F i s a l s o r e l e a s e d

    No n r esp on se f ro m t he m ob il e a ft er D N_ NA SS IG NM AX P ac ke tDownlink Assignment messages

    No n r esp on se f ro m t he m ob il e a ft er D N_ NA SS IG NM AX P ac ke tD o wn l in k A ss i gn m en t m e ss ag e s d u ri n g f u l l d u pl e x t r an sf e r, i n t h e c a se

    t h a t t h e D L T B F i s a l s o r e l e a s e d

    N o n r e s p on se f r o m t h e m o b i le a f t er N N 00 0 2 d o w n li n k d a t a b l oc k s s e ntwith FBI=1 and S/P=1

    N o n r e s p on se f r o m t h e m o b i le a f t er N N 00 0 2 d o w n li n k d a t a b l oc k s s e ntwith FBI=1 and S/P=1 during full duplex transfer, in the case that the ULT B F i s a l s o r e l e a s e d

    P r e e mp t i o n o f r a d i o t i m e s l o t s

    C e ll r e se l ec t i on f r o m c e l l A t o c el l B a n d e s ta bl i sh m en t o f a n e w u p li n kT B F i n c e l l B

    C r e at e d n e w p a r ag r a p h 1 -- 6 R a w P e r m an e n t P C U SN O b s er v a t i on C o u nt e r s

    C h a p t e r 2 C o u n t e r D e s c r i p t i o n :

    T h e f o l l o w i ng c o u n t e r s h a v e b e e n m o d i f ie d :

    1056 tchAveragedAvailableMoy/Max/Cum/Ech

    1068 hoSuccessOutgoingInterBss

    1078 hoSuccessOutgoingFirstInter

    1700 tchAveragedAvailableTrZoneMoy/Max/Cum/Ech

    15028/1 upMultiSlotRequest1

    15028/2 upMultiSlotRequest2

    15028/3 upMultiSlotRequest3

    15028/4 upMultiSlotRequest4

    15030/1 dwMultiSlotRequest1

    15030/2 dwMultiSlotRequest2

    15030/3 dwMultiSlotRequest3

    15030/4 dwMultiSlotRequest4

    15031/1 FirstDlUnitDataFrame

  • 8/11/2019 Nortel Counters Description

    17/1041

    Publication HistoryNortel Networks Confidential xv

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    15031/2 dlTBFAllocFailure

    15031/3 dlTBFRadioFailure

    15032/3 ulsecondPhaseAllocFailure

    15034/0 PDANWithUlReq

    15036/0 ulsecondPhaseRadioFailure

    15041/0 upUserdatablocks

    15043/0 RequestedRetransmittedDataBlocksDN

    15058/4 dnPipebetween22and33kbps

    15061/0 upPipeless11kbps

    June 2002

    I s s u e 1 3 . 0 4 / E N D r a f t

    March 2002

    I s s u e 1 3 . 0 3 / E N S t a n d a r d

    C h a ng e d t o S t a n da r d -- m i n or e d i t or i a l u p d at e

    August 2001

    I s s u e 1 3 . 0 2 / E N P r e l i m i n a r y

    V13.1 release update after internal review

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    About this document

    updated Paragraph Applicability

    u p d at e d P a r a g r a ph H o w t h i s d o c u m en t i s o r g an i z e d

    C h a p t e r 1 I n t r o d u c t i o n

    u p d at e d P a r a g r a p h 1 . 1 . 1 . 1 O b s er v a t i on t y p es

    r e m o ve d P a r a gr a p h 1 . 4 I n st r u m e nt p a n el o b se r v a ti o n c o u nt e r s ( V1 0 )

    r e m o ve d P a r a g r a ph 1 . 5 . 2 P CM l i n k s

    r e m o ve d P a r a g r a p h 1 . 5 . 3 H a nd o v er s

    u pd a te d P a ra g ra p h 1 . 6. 2 . 1 R a w p e rm a ne n t c o un t er s s et t ab l e b y t h e o p e r at o r

    c r ea t ed n e w P a r ag r ap h 1 . 6. 3 C or r e sp on d en c e b e tw ee n B S C 2 G a nd B S C e 3Counters

  • 8/11/2019 Nortel Counters Description

    18/1041

    Publication History Nortel Networks Confidentialxvi

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    u p d at e d P a r a g r a p h 1 . 7 . 2 . 1 C o u n te r n u m be r i n g

    u p d at e d P a r a g r a ph 1 . 7 . 3 C o u nt e r d e f i n i t i o n

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    r e m o ve d P a r a g r a p h 2 . 2 R a w i n s t r u m e nt p a n el c o u nt e r s

    r e m o ve d P a r a gr a p h 2 . 4 . 3 Te m p or a r y P C M o b s e r v at i o n

    r e m o ve d P a r a gr a p h 2 . 4 . 4 Te m p or a r y H a n do v e r o b s e r v at i o n

    r em ov ed P ar ag ra ph 2 .6 Sy nt he ti c i ns tr um en t p an el ( IP O a nd O RT )counters

    u p da t ed t h e F u n c ti o n a n d E v en t f i el d s o f t h e c o u nt e r s 1 5 0 57 / 0 t o 1 50 5 7/ 4

    u p da t ed t h e F u n c ti o n a n d E v en t f i el d s o f t h e c o u nt e r s 1 5 0 58 / 0 a n d 1 5 05 8 /1 c r ea t ed t h e n e w c o un t er s 1 5 07 5 /0 t o 1 5 07 5 /4 , a n d 1 5 0 76 / 0 t o 1 5 07 6 /1

    July 2001

    I s s u e 1 3 . 0 1 / E N D r a f t

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 1 I n t r o d u c t i o n

    u p d at e d P a r a g r a ph 1 . 1 . 1. 1 O b se r v a ti o n t y p e s w i t h c o m p l e t i on o f t h e V 1 3

    r e l e a s e c o l u m n

    c r e a te d P a r a g r ap h 1 . 2 . 2 . 3 A b n or m a l C o m p l et i o n s w i t h i n t e gr a t i o n o f t h ef o l l o w i n g d a t a f l o w d i a g r a m s ( D F D s ) :

    n o a v a i l a b le r e s ou r c e ( S D C C H)

    n e g at i v e r e s po n s e f r o m t h e B T S

    no r esponse to CHANNEL ACTIVATE

    t i m e r 3 1 0 1 e x p i r y

    i n c o r r ec t f i r s t L 3 m e s sa g e

    t r af f i c w i t h t h e M S C c l o se d CONNECTION FAILURE indication

    ERROR INDICATION

    r e j ec t io n f r o m t h e M S C

    u p da t ed P a r ag r ap h 1 . 2. 7 .4 w i th i n te g ra t io n o f t h e c o un t er s 3 0 00 / n t o 3 0 08 / n

    r e na m ed P a ra g ra ph 1 . 6. 1 Ra w c ou n te r c o nf i g ur a t io n b y Ra w c o un t erc o n f i g u r a t i o n ( B S C 2 G )

    c re at ed P ar ag ra ph 1 .6 .2 Ra w c ou nt er c on fi gu ra ti on ( BS C e 3) w it hi n t e g r a t i o n o f t h e c o u n t e r s 3 0 0 0 / n t o 3 0 0 8 / n

  • 8/11/2019 Nortel Counters Description

    19/1041

    Publication HistoryNortel Networks Confidential xvii

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    c re at ed P ar ag ra ph 2 .3 Ra w p er ma ne nt B SS c ou nt er s ( BS C e 3) w it hd e s c r i p t i o n o f t h e f o l l o w i n g c o u n t e r s :

    3 0 0 0/ n t o 3 0 0 8 / n

    Appendix A V13 Release Counters

    c r e at e d P a r a g r a ph A . 1 V 1 3 r e l e as e c o u n t er s

    c r ea t ed P a ra gr a ph A . 1. 1 N ew V 1 3 c ou n te r s w i th i n te g ra t io n o f t h e c o un t er s3 0 0 0 / n t o 3 0 0 8 / n

    System release: GSM/BSS V12

    July 2001

    I s s u e 1 2 . 0 9 / E N S t a n d a r d

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 1 I n t r o d u c t i o n

    i n t e gr a t e d t h e f o l l o w i n g d a t a f l o w d i a g r a m s ( D F D s) :

    I m m e di a t e a s s i g nm e n t : p a g i n g ( n o r m a l c o m p l e t i on ) , P a r a g ra p h 1 .2.2.2 D e d ic a t ed c h an n e l a s s i gn m e nt : m o d e m o d i f y, P a r a gr a p h 1 .2.3.2

    I n t r a -- b t s h a n do v e r ( n o r m al c o m pl e t i o n) , P a r a gr a p h 1 . 2 . 4 . 3

    I n t e r -- b s s h a n do v e r ( n o r m al c o m pl e t i o n) , P a r a gr a p h 1 . 2 . 4 .5

    D i r e ct r e t r y h a n d o ve r, P a r a gr a p h 1 . 2 . 4 . 6

    R ad i o c ha nn e l r e l ea se ( D EA C TI VAT E S A CC H A C K r e ce i ve d b ef o r eR E L E A S E I N D I C A T I O N ) , P a r a g r a p h 1 . 2 . 5 . 1

    R ad io c ha nn el r el ea se ( RE LE AS E I ND I CAT I ON r ec ei ve d b ef or e

    D E A C T I V A T E S A C C H A C K ) , P a r a g r a p h 1 . 2 . 5 . 1 C on ne ct ion c lear ing r equ ir ed b y t he BS C ( nor mal com pl et ion ),

    P a r a g r a p h 1 . 2 . 5 . 2

    S M S s e r vi c e , P a r a gr a p h 1 . 2 . 6

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    A n sw e r t o t h e S e r v i ce R e q u e st :

    HB10400 ( SR 30361193) : r enamed count ersccpResourceFailureBscFailure by sccpResourceFailureBscRefusal

    u p d at e d P a r a g r ap h 2 . 8 . 2 :

  • 8/11/2019 Nortel Counters Description

    20/1041

    Publication History Nortel Networks Confidentialxviii

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    r e mo v ed a l l t h e f i e l ds ( Q 3 n am e , O b je c t, F u nc t io n, E v en t , e t c .) o f P CU

    c o u n t e r s r e s e r v e d f o r t h e m a n u f a c t u r e r u p da t ed t h e E v e nt f i e ld o f t h e c o u nt e r 1 5 0 32 / 0

    r e n u mb e r e d t h e c o u nt e r 1 5 0 4 4 b y 1 5 0 4 4 / 0

    u p da t ed t h e F u n ct i on a n d E v e nt f i el d s o f t h e c o u nt e r 1 5 0 4 8/ 1

    u p da t ed t h e E v e nt f i e ld o f t h e c o u nt e r 1 5 0 50 / 0

    u p da t ed t h e E v e nt f i e ld o f t h e c o u nt e r 1 5 0 51 / 0

    c h a ng e d t h e c o u n t er 1 5 0 52 b y 1 5 0 52 / 0

    u p da t ed t h e F u nc t io n f i e l d o f c o un t er s 1 5 0 54 / 0 t o 1 5 05 4 /4

    c h an ge d t h e t i tl e o f t h e c o u nt e r 1 5 0 58 / 0 u p da t ed t h e N o t e f i e l d o f t h e c o un t er 1 5 06 6 /0

    May 2001

    I s s u e 1 2 . 0 8 / E N P r e l i m i n a r y

    V 1 2 . 4 r e l e a s e u p d a t e a f t e r i n t e r n a l r e v i e w

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 1 I n t r o d u c t i o n

    c r e at e d P a r a g r a ph 1 . 3 . 3 P D T C H r e s o ur c e s

    i n t e gr a t e d t h e f o l l o w i n g d a t a f l o w d i a g r a m s ( D F D s) :

    i m m e di a t e a s s i g nm e n t ( n o r m a l c o m pl e t i o n) , P a r a gr a p h 1 . 2 . 2 . 1

    q ue ui ng i n t he assi gn me nt pr oced ur e ( suc cessf ul com pl et ion ),P a r a g r a p h 1 . 2 . 2 . 3

    d e d ic a t e d c h a n n el a s si g n m en t ( n o r m al c o m pl e t i on ) , P a r a gr a p h 1 . 2 . 3. 1

    d e d ic a t ed c h an n e l a s s i g nm e n t ( n o r e s ou r c e a v a i l a bl e ) , P a r a gr a p h 1 . 2 . 3 . 3

    i n t e r -- c e l l i n t r a -- b s s h a n do v e r ( n o r m al c o m pl e t i o n w i t h c o m m un i c a ti o n o nT R A F F I C p h a s e ) , P a r a g r a p h 1 . 2 . 4 . 4

    con nec ti on cl ear in g r eq ui red by t he MS C ( no rm al co mpl et io n) ,P a r a g r a p h 1 . 2 . 5 . 2

    G P R S p r o c e d ur e ( n o r m al c o m pl e t i on ) , P a r a gr a p h 1 . 2 . 7 . 1

    G PR S p ro ce du re ( no r eso ur ce a va il ab le f or P DT CH p re em pt io n) ,P a r a g r a p h 1 . 2 . 7 . 2

    G P RS p r oc ed u re ( n eg a ti v e a c kn o wl e dg e me nt b y t h e P C U a f t e r t h e B S Cat tempted t o pr eempt a PDT CH to make a T CH channel) ,P a r a g r a p h 1 . 2 . 7 . 3

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    u p d at e d e x i s t i ng D a ta f l o w s f i e l d s a n d c r e a t e d n e w o n e s

  • 8/11/2019 Nortel Counters Description

    21/1041

    Publication HistoryNortel Networks Confidential xix

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    April 2001

    I s s u e 1 2 . 0 7 / E N D r a f t

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 1 I n t r o d u c t i o n

    c r e at e d P a ra gr a ph 1 . 2. 7 G PR S a n d a dd ed t h r ee d at a f l o w d i ag r am s ( D FD s) :

    G P R S p r o c e du r e ( n o r m a l c o m p l e t i on )

    G P R S p r o c e du r e ( n o r e s ou r c e a v a i l ab l e f o r P D T CH p r e e mp t i o n)

    G P RS p r o c ed u re ( n eg a ti v e a c kn o wl e dg e me n t b y t h e P C U a f t er a P D TC Hpreemption)

    g a ve t h e l i s t o f t h e 1 9 3 c ou n te r s i m p a ct e d b y t h e c i r c ui t /p a ck e t a s p ec t

    c r e at e d n e w D F Ds :

    d e d ic a t ed c h a nn e l a s si g n m en t ( n o r e s ou r c e a v a i l a b l e)

    q u e ui n g i n t h e a s s i g nm e n t p r o c e d ur e ( n o r m al c o m pl e t i o n)

    u p d at e d e x i s ti n g D F D s :

    i m m e di a t e a s s i g nm e n t ( n o r m a l c o m pl e t i o n)

    d e d ic a t e d c h a n n el a s si g n m en t ( n o r m al c o m pl e t i o n)

    i n t e r ce l l h a n d o v er ( n o r m al c o m pl e t i o n)

    c o n ne c t i on c l e ar i n g r e q u i r e d b y t h e M S C ( n o r m al c o m pl e t i o n)

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    A n sw e r t o S e r v i ce R e q u e st s :

    NK10370: cor r ected count er number f or counter s 15053/0nbSamplesUpQuality and 15053/1 nbSamplesDnQuality

    NK10371: cor r ected count er number f or counter s 15058/2dnTbfImmediateAssignment and 15058/1 upTbfImmAssigRejectNoPdch

    N K 1 02 3 1 : u p d a te d d e f i n i t i on o f c o u n t e r 1 0 5 7

    E E 1 0 11 3 : u p d a t e d d e f i n i t io n o f c o u nt e r 1 0 5 7 N K 10 2 45 : a dd e d D F Ds f o r t h e f o ll o wi n g c o un t er s : 1 0 39 , 1 0 52 , 1 05 7 ,

    1 6 0 9 , 1 6 1 1 , 1 8 1 2 , 1 8 1 3 , 1 8 1 4 , 1 8 1 5

    N K 1 02 0 0 : u p d a te d d e f i n i t i on o f c o u n t e r s 1 8 1 2 a n d 1 8 1 3

    S R 3 0 3 4 9 6 41 ( m a s te r S R 3 0 3 1 8 3 53 ) : u p d a t e d d e f i n i ti o n o f c o u nt e r 1 8 1 2

    H K 1 05 2 2 : u p d a t e d d e f i n i t i on o f c o u nt e r s 1 6 0 9 / 0 , 1 6 0 9 / 2 , 1 6 1 1 / 0, 1 6 11 / 2

    E R 1 00 1 3 : u p d a t ed d e f i n i t i o n o f c o u nt e r 1 7 0 0

    u pd at ed t he d ef in it io n o f a ll t he c ou nt er s c on ce rn ed b y T CH /F R a ndp r e e m p t e d P D T C H

  • 8/11/2019 Nortel Counters Description

    22/1041

    Publication History Nortel Networks Confidentialxx

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    u p d at e d t h e a v a i l a b i li t y d a t e o f P C U SN c o u n t e r s ( P a r a gr a p h 2 . 8 )

    March 2001

    I s s u e 1 2 . 0 6 / E N D r a f t

    V12.4 release update after internal review

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    u pd at ed t he d es cr i pt i on o f t he t r ig ge ri ng e ve nt o f C 15 02 9/ 1, C 15 02 9/ 2,C 1 5 0 2 9 / 3 , C 1 5 0 2 9 / 4 , C 1 5 0 3 1 / 1 , C 1 5 0 3 1 / 2 , C 1 5 0 3 1 / 3 , C 1 5 0 3 1 / 4

    u p da t ed t h e d e sc r i pt i on o f t h e f u nc t io n o f C 15 0 39 , C 1 50 4 0/ 0 , C 1 50 4 2/ 0 ,C15042/2, C15044

    January 2001

    I s s u e 1 2 . 0 5 / E N D r a f t

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    A n sw e r t o S e r v i ce R e q u e st s :

    S R 3 0 3 30 3 9 5 ( 3 0 4 3 0 4 23 ) : r e m o ve d C 1 5 05 7 / 5 l o s s O f C om N T 1 00 1

    S R E E 0 0 5 2 6 ( 3 0 3 40 2 5 4) : a d d e d t oC9500 bscSdcchAveragedUsedMoy/Max/Ech/Cum and toC9501 bscTchFrAveragedUsedMoy/Max/Ech/Cum, Paragraph 2.5

    c o m pl e t e d t h e d e s c r i pt i o n o f P C U SN c o u n t e r s, P a r ag r a p h 2 . 8

    a dd ed d at a f l ow d ia gr a ms t o t he d es cr i pt io n o f c ou nt er s C 18 12 , C 18 13 ,C 1 8 1 4 , a n d C 1 8 1 5 , P a r a g r a p h 2 . 1

    September 2000

    I s s u e 1 2 . 0 4 / E N S t a n d a r d

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    A n sw e r t o S e r v i ce R e q u e st s :

    E E0 05 25 C 18 39 /n a nd C 18 40 /n l oc at io n i s n ot o n b ts o bj ec t, b ut o nadjacentCellHandOver object

    c o m pl e t e d t h e d e s c r i p t io n o f C 11 6 1 / 5, a n d C 1 6 2 9 /0

    a d d ed t h r e e s y n t h e ti c G S M -- R s p ec i f i c c o u n t e r s: C 8 9 12 , C 8 91 3 , a n d C 8 9 1 9

  • 8/11/2019 Nortel Counters Description

    23/1041

    Publication HistoryNortel Networks Confidential xxi

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    June 2000

    I s s u e 1 2 . 0 3 / E N P r e l i m i n a r y

    V12.4 release update after internal review

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    U p da t ed 1 0 c ou n te r s ( 1 02 8 , 1 0 29 , 1 0 30 , 1 0 31 , 11 6 3/ 1 6, 11 6 3/ 1 7, 11 6 4/ 1 6,1 1 6 4 / 1 7 , 1 6 0 4 , 1 6 0 5 )

    Answer to Service Requests:

    H T 9 02 8 9 : a d d ed c o u n t e r 1 7 3 0

    E E 9 0 23 5 : a d d e d c o u n te r s 8 7 2 3 , 8 7 2 4 , 8 7 2 5 , 8 7 3 6

    3 0 09 2 37 1 : n o te d t h at c ou n te r s 1 7 66 / 0, 1 7 66 / 1, 1 7 67 / 0 a nd 1 7 67 / 1 a r e V 1 1specific counters

    3 0 11 2 3 59 : u p d at e d c o u n t er s 1 8 0 3/ 0 t o 1 8 0 3 / 4

    3 0 11 4 0 15 : a d d ed c o u nt e r 1 8 4 1 / 1

    3 0 1 24 2 9 2: c o u nt e r 1 10 6 b e c am e c o un t e r 1 1 0 6 /0 a n d c o u n t e r 1 1 0 6/ 1

    3 0 1 25 5 6 1: a d d ed c o u n t e r 1 7 0 0 i n O RT l i s t

    3 01 2 74 17 : c o un t er s 1 6 00 a nd 1 6 03 , 1 6 23 a nd 1 6 24 , 1 6 25 a nd 1 62 6 c r ea t edf o r t r a n s c e i v e r Z o n e o b j e c t

    3 0 1 27 4 1 8: c o u nt e r s 1 0 5 7 a n d 1 0 6 0 a r e c r e a t e d f o r t r a n sc e i v er Z o n e o b j e ct

    3 0 1 35 1 2 6: a d d ed c o u nt e r 8 0 4 0 ( s y n t he t i c p e r m a n en t )

    March 2000

    I s s u e 1 2 . 0 2 / E N D r a f t

    V 1 2 . 4 r e l e a s e u p d a t e

    T h e f o l l o w i n g c h a n g e s w e r e m a d e i n i n d i v i d u a l c h a p t e r s :

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n

    a d d ed G P R S c o u n te r s

    a d d ed c o u n t e r s r e l a t ed t o f e a t u re T F 9 9 5 A u t o m a t ic c e l l t i e r i n g

    January 2000

    I s s u e 1 2 . 0 1 / E N D r a f t

    Creation:

    C ha pt er 1 In tr od uc ti on c on ta in s t he f or m er C ha pt er 4 BS S o bs er va ti onp r i n c i p l e s w h i c h w a s r e m o v e d f r o m M a n u a l < 0 7 > .

    C h a p t e r 2 C o u n t e r d e s c r i p t i o n c o n t a i n s t h e f o r m e r C h a p t e r 5 D i c t i o n a r y o f o b s e r v a t i o n c o u n t e r s w h i c h w a s r e m o v e d f r o m M a n u a l < 0 7 > .

  • 8/11/2019 Nortel Counters Description

    24/1041

    Publication History Nortel Networks Confidentialxxii

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    P A G E I N T E N T I O N A L L Y L E F T B L A N K

  • 8/11/2019 Nortel Counters Description

    25/1041

    Table of contentsNortel Networks Confidential xxiii

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    About this document 0--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Applicability 0--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Precautionary message 0--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Audience 0--2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Prerequisites 0--2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    How this document is organized 0--2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Vocabulary conventions 0--2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1 Introduction 1--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1 BSS observations 1--3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1.1 Observation management principles 1--3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1.2 Observation counters 1--4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1.3 Observation classes 1--9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.1.4 Mobility Class Sensitivity Counters 1--9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2 Observation counter incrementation principles and data flow diagram (DFD) 1--10. . . .

    1.2.1 Radio resource allocation 1--10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.2 Call setup 1--12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.3 Dedicated channel assignment 1--49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.4 Handovers 1--66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2.5 Resource release 1--93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.6 SMS service 1--113. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.7 GPRS 1--117. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.8 GPRS/EDGE Suspend and Resume 1--142. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.9 BSC equipment 1--152. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.10 PCUSN 1--153. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.2.11 Advanced Speech Call Items (GSM--R) 1--211. . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3 Permanent bsc observation counters 1--215. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.1 Counter classes 1--215. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.2 Common control channel monitoring 1--215. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.3 Radio resource allocation 1--215. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.4 Interferences 1--218. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.5 Call setup 1--220. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.6 Dedicated channel assignment 1--220. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.7 Directed retry handovers 1--222. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.8 Handovers 1--223. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.9 Radio resource release 1--228. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 8/11/2019 Nortel Counters Description

    26/1041

    Table of contents Nortel Networks Confidentialxxiv

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1.3.10 SMS service 1--231. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.11 Layer 1 management 1--232. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.12 A interface 1--232. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.13 Abis interface 1--233. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.14 BSS/OMC--R link 1--233. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.15 PCM links 1--233. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.16 BSC equipment 1--234. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.17 GPRS 1--235. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.18 GPRS / EDGE Suspend and Resume 1--237. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.3.19 ASCI (GSM--R V12, V15) 1--237. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.4 Raw permanent BSS counters configuration 1--239. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.4.1 Raw counters configuration (all BSC) 1--239. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.4.2 Correspondence between BSC2G and BSC 3000 counters 1--268. . . . . . . . .

    1.5 Synthetic permanent BSS counters configuration 1--270. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.6 Temporary observation counters (BSC 2G) 1--274. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.6.1 SS7 links 1--274. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.6.2 Abis interface 1--275. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.7 Raw Permanent PCUSN Observation Counters 1--276. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.7.1 PCUSN Observation Classes 1--276. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.7.2 PCUSN Observation Types 1--278. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    1.7.3 Throughput Counters and Satisfaction Rate Counters 1-- 285. . . . . . . . . . . . . .

    2 Counter description 2--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1 Dictionary presentation 2--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1.1 Dictionary contents 2--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1.2 Observation counter references 2--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1.3 Counter definition 2--2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.1.4 Basic definitions 2--4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.2 Raw permanent BSS counters (BSC 2G) 2--7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.3 Raw permanent BSS counters (BSC 3000, AMR) 2--28. . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.3.1 Raw permanent BSS counters (BSC 3000) 2--28. . . . . . . . . . . . . . . . . . . . . . .

    2.3.2 Raw permanent BSS counters (AMR) 2--53. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.4 Raw permanent BSS counters (common to BSC 2G, BSC 3000, and AMR) 2--102. . . .

    2.5 Raw temporary counters (odiag excluded) 2--460. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.5.1 Temporary Interference observation 2--460. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.5.2 Temporary SS7 link observation 2--460. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 8/11/2019 Nortel Counters Description

    27/1041

    Table of contentsNortel Networks Confidential xxv

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    2.5.3 Temporary Abis interface observation 2--463. . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.6 Synthetic permanent BSS counters 2--472. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.7 Raw permanent md counters 2--529. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.7.1 SYBASE counters 2--529. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.7.2 SCSE counters 2--533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.7.3 UNIX counters 2--534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.7.4 Q3 counters 2--539. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.8 Raw permanent manager counters 2--552. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.8.1 SYBASE counters 2--552. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.8.2 X.25 counters 2--556. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.8.3 UNIX counters 2--557. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.9 Raw permanent PCUSN counters 2--561. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Appendix A Release counters 3--1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 8/11/2019 Nortel Counters Description

    28/1041

    List of figures Nortel Networks Confidentialxxvi

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    Figure 1--1 Guidelines for locating a BSS observation counter 1--2. . . . . . . . . . . . . . . . . . . . . .

    Figure 1--2 Observation Classes 1--277. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 8/11/2019 Nortel Counters Description

    29/1041

    About this documentNortel Networks Confidential 0--1

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    ABOUT THIS DOCUMENT

    T h is O b se r va t io n C ou n te r D i ct i on a ry i s a r e f er e nc e g u id e d e sc r ib i ng a l l G S M B S Sn e t wo r k o b se r v a ti o n c o u nt e r s m a n ag e d t h r o ug h t h e O M C -- R .

    Applicability

    T h i s d o c u m e n t a p p l i e s t o t h e V 1 5 . 1 B S S s y s t e m r e l e a s e .

    T h i s d o c u me n t i s p a r t o f t h e B S S N o r t e l N e t w o r k s Te c h ni c a l P u b l i c at i o n s ( N T P s) .

    I t i s c l o s e l y a s s o c i a t e d w i t h t h e f o l l o w i n g m a n u a l s :

    T h e B S S O p er a t in g P r i nc i pl e s m a nu a l ( N T P < 0 7 > ) d es cr i be s g en e ra l o p er a ti n gp r i nc i pl e s a nd e xp l ai n s t h e m e ch a ni s ms t h at e na b le M a n- Ma ch i ne i n te r f ac ecommands.

    T h e B S S P a r a m e t e r D i c t i o n a r y ( N T P < 1 2 4 > ) c o n t a i n s a l l t h e p a r a m e t e r s u s e din OMC--R commands.

    T he OMC -- R User Manual ( NTPs < 128 >, < 129 > and < 130 >) is au s e r - o r i e n t e d g u i d e t o p e r f o r m i n g H u m a n - M a c h i n e i n t e r f a c e c o m m a n d s .

    T he B SS O pe ra ti ng P ro ce du re s M an ua l ( NT P < 34 >) d es cr ib es v ar io usp r o c e d u r e s t h a t h e l p u s e r s o p e r a t e o r r e c o n f i g u r e a B S S .

    Precautionary message

    T h e f o l l o w i n g m e s s a g e :

    CAUTION

    GSM--R specific

    Indicates that specific equipment and specific software (such asspecific software in the BSC) dedicated to Railway application isused and that the feature is therefore not available for all standardGSM users.

    S o m e G S M -- R s p ec i f i c c o u nt e r s l i s t ed i n t h i s d i c t i on a r y c o n t ai n ( G S M -- R V 1 2 ) i n t h e F e a t u r e f i e l d b e c a u s e t h e y w e r e i n t r o d u c e d i n V 1 2 .

  • 8/11/2019 Nortel Counters Description

    30/1041

    About this document Nortel Networks Confidential0--2

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    Audience

    T h i s d o c u m e n t i s i n t e n d e d f o r :

    OMC--R administrators

    OMC--R maintenance attendants

    G S M n e t w o r k e n g i n e e r s

    u se r s w h o w a nt t o k n ow m o re a b ou t O MC -- R

    Prerequisites

    U s e r s m u s t b e f a m i l i a r w i t h n e t w o r k i n g p r i n c i p l e s .T h e y m u s t a l s o b e f a m i l i a r w i t h t h e f o l l o w i n g m a n u a l s :

    < 0 0 > : B SS P ro du ct D oc um en ta ti on O ve rv ie w

    < 01 > : BSS Over vi ew

    < 0 6 > : O MC -- R A r ch it ec tu r e an d Re fe re nc e Ma nu al

    < 07 > : B SS Oper at in g P ri nci pl es

    < 3 2 > : O MC -- R P r ev en ti ve a n d C or r ec ti ve M a in te na nc e M an ua l

    < 34 > : B SS Op er at ing pr oc edur es

    < 1 24 > : B SS P ar am et er D i ct io na ry< 1 28 > : O MC -- R U s er M an ua l -- Vo lu me 1 o f 3 : O bj ec t a n d F a ul t m e nu s

    < 1 2 9 > : O M C -- R U se r M a n ua l -- Vo l um e 2 o f 3 : C o nf i g ur a t io n , P e r f or m an c e,a n d M a i n t e n a n c e m e n u s

    < 1 3 0 > : O M C -- R U s er M an u al -- Vo l um e 3 o f 3 : S e cu r it y, A d mi n is tr a t io n ,S M S -- C B , a n d H e l p m e n us

    How this document is organized

    T h i s d o c u m e n t i s o r g a n i z e d i n t o t w o m a i n c h a p t e r s :C h ap t e r 1 I n t r o du c t i on c o n t ai n s g e n er a l i n f o r m at i o n o n o b se r v a t io n c o u nt e r s .

    C h ap t e r 2 C o un t e r d e s cr i p t i on d e sc r i b es a l l t h e o b se r v a ti o n c o u n t e r s l i s t e d b yf a m i l i e s , a n d e x p l a i n s t h e i r u s e .

    Appendix A V15 release counters highlights the differences between V15,V 1 4 , V 1 3 , a n d V 1 2 r e l e a s e o b s e r v a t i o n c o u n t e r s .

    Vocabulary conventions

    T h e g l o s s a r y i s p r e s e n t e d i n M a n u a l < 0 0 > .

  • 8/11/2019 Nortel Counters Description

    31/1041

    IntroductionNortel Networks Confidential 1--1

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1 INTRODUCTION

    T h i s c h a p t e r c o n t a i n s t h e f o l l o w i n g i n f o r m a t i o n :

    After a brief reminder of the principles underlying BSS observations detailed inN T P < 0 7 > , t h e s t r u c t u r e a n d c o n t e n t s o f t h e B S S o b s e r v a t i o n c o u n t e r s , w i t ht h e i r a c co u n t i ng a l g or i t h m s, a r e d e sc r i b ed a n d t h e o b s er v a t i on c l a ss e s d e f i n e d( s e e P a r a g r a p h 1 . 1 ) .

    T he n t he v ar io us d ia gr am s i ll us tr at e t he p ri nc ip le s u nd er ly in g c ou nt eri n cr e me n ts b a se d o n t h e t r a ff i c m a na ge m en t p r oc e du r es e x ec ut e d b y t h e B S C( s e e P a r a g r a p h 1 . 2 ) .

    T h e f o l l o w i n g p a r a g r a p h s l i s t : t h e r a w p e r m an e n t B S S o b s e r v a ti o n c o u n t er s ( s e e P a r a g r ap h 1 . 3 )

    t e m po r a r y o b s e r v at i o n c o u n t er s a p p ea r i n g i n V 1 2 B S S o b se r v a ti o n r e p o r t s( s e e P a r a g r a p h 1 . 6 ) a n d B S C V 1 5 2 G

    C o un t er s a r e l i st e d a cc o rd i ng t o t h ei r c l as s a n d a r e i d en t if i e d b y t h ei r n u mb e r a ndQ 3 n a m e . T h e t y p e i s a l s o i n d i c a t e d .

    T he f o ur o bs er v at io n t yp es ( O RT, O FS , O GS , a nd O DI AG ) a va il ab le w it hp e r m a n e n t o b s e r v a t i o n c o u n t e r s a r e d e s c r i b e d i n P a r a g r a p h 1 . 4 .

    T h e s t r u c t u r e o f t h e D i c t i o n a r y i s p r e s e n t e d i n P a r a g r a p h 2 . 1 .

    The f ol lo wi ng f ig ur e p ro vi de s t he u se r w it h g ui de li ne s f or l oc at in g a B SSo b s e r v a t i o n c o u n t e r i n t h e d i c t i o n a r y o f c o u n t e r s , s t a r t i n g f r o m d i f f e r e n t p o i n t s .

  • 8/11/2019 Nortel Counters Description

    32/1041

    Introduction Nortel Networks Confidential1--2

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    Starting point

    See Paragraphs1.3 to 1.4

    See the index ofcounters at the end

    of the manual

    The type and class ofthe counter are known

    (for example:permanent/handover)

    The Q3 name of thecounter is known

    (for example: assign-Failure)

    The number of thecounter is known(for example: 1055)

    Search for the counter in the Dictionary of counters(numerical lists in Chapter 2)

    Figure 1--1 Guidelines for locating a BSS observation counter

  • 8/11/2019 Nortel Counters Description

    33/1041

    IntroductionNortel Networks Confidential 1--3

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1.1 BSS observations

    1.1.1 Observation management principles

    1.1.1.1 Observation types

    B S S o b s e r v a t i o n s c o v e r s t h e f o l l o w i n g :

    B S S p e r m a n e n t o b s e r v a t i o n

    G en e ra l s t a t is t ic o b se r va t io n ( O G S ) ( a p r ev i ew o f t h e r e p or t i s v i s i bl e i n t h ep e r f o rm a n ce w i n do w a t t h e O M C -- R )

    F a st s t at i st i c o b se r va t io n ( O FS ) ( v i si b le i n t h e R e po r t w i nd o w a t t h e O M C -- R )

    R ea l t im e o bs er va ti on ( ORT ) ( a p re vi ew o f t he r ep or t i s v isi bl e i n t heP e r f o r ma n c e w i n d ow o f t h e O M C -- R )

    Diagnostic observation (ODIAG)

    Temporary Observation

    Interference temporary observation

    A b i s I n t e r f ac e t e m p o r a r y o b s er v a t i on

    S S 7 l i n k t e m p o r ar y o b s e r v at i o n

    T h e B S S o b s e r v a t i o n s a p p l y t o t h e f o l l o w i n g B S C t y p e s :

    BSC typeObservation type

    BSC 2G BSC 3000

    OGS X X

    OFS X X

    ORT X X

    Temporary Interference X

    Temporary Abis Interface X

    Temporary SS7 Link X

    ODIAG X X

    1.1.1.2 Observation management

    BS S ob se rvat ions ar e act ivat ed b y cr eat ing m dS can ner o bj ect s wh osemdGranularityPeriod a t tr i bu te d ef i ne s t he p er i od s a t w hi ch t he o bs er va ti onc o u nt e r s a r e r e a d a n d t r a n sf e r r e d t o t h e O M C -- R a g e nt .

    W h e n a B S S o b s e r v a t i o n i s a c t i v a t e d , a l l t h e r e l a t e d c o u n t e r s s t a r t c o u n t i n g . W h e nt he o bs er va ti on i s d ea ct i va te d, t he c ou nt er s s to p c ou nt in g; t he y a re n o l on ge rcollected.

  • 8/11/2019 Nortel Counters Description

    34/1041

    Introduction Nortel Networks Confidential1--4

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1.1.1.3 Observed entities

    T h e o b s e r v e d e n t i t i e s a r e s h a r e d b e t w e e n t h r e e m a i n g r o u p s :

    R a d i o r e s o u r c e s , i n c l u d i n g r a d i o c h a n n e l s , s e r v i n g c e l l s , a n d n e i g h b o r c e l l s

    D a t a l i n k s , i n c l u d i n g A a n d A b i s i n t e r f a c e s

    E q ui p me n t, i n cl u di n g B S C e q ui p me n t, P CU S N e qu i pm e nt , P CM l i nk s, a ndBSS/OMC --R link

    1.1.1.4 Observation domains

    T he e va lu at io n o f n et wo rk p er fo rm an ce b ase d o n t he r es ul ts o f r ad io e nt it y

    o b s e r v a t i o n c o v e r s f o u r d o m a i n s :t r a f f i c l o a d

    q u a l i t y o f s e r v i c e

    resource availability

    n e t w o r k c o n f i g u r a t i o n c o n t r o l

    1.1.1.5 Observations and alarms

    O b s e r v a t i o n s c a n h a v e a n a s s o c i a t e d t h r e s h o l d .

    P e r f o r m a n c e m a n a g e m e n t c a n g e n e r a t e a n a l a r m w h e n a t h r e s h o l d i s c r o s s e d o n ag i v e n o b s e r v a t i o n . T h i s m e c h a n i s m a p p l i e s t o :

    B S S G S M o b s e r v a t i o n s

    B S S P C U ( G P R S ) o b s e r v a t i o n s ( s y n t h e t i c c o u n t e r s )

    1.1.2 Observation counters

    1.1.2.1 Counter types

    T h e r e a r e t h r e e t y p e s o f o b s e r v a t i o n c o u n t e r :totalizer

    value

    load

  • 8/11/2019 Nortel Counters Description

    35/1041

    IntroductionNortel Networks Confidential 1--5

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1.1.2.2 Counter contents

    Header

    E a c h o b s e r v a t i o n c o u n t e r h a s a h e a d e r c o n t a i n i n g t h e f o l l o w i n g t h r e e f i e l d s :

    COUNTER TYPE

    COUNTER IDENTIFIER

    SCREENING CRITERIA

    COUNTER TYPE i d e n t i f i e s t h e t y p e o f t h e c o u n t e r ( t o t a l i z e r , v a l u e , l o a d )

    COUNTER IDENTIFIER i d e n t i f i e s t h e o b s e r v a t i o n c o u n t e r . T h i s i d e n t i f i e r i s r e l a t e dt o t h e c o u n t i n g f u n c t i o n

    SCREENING CRITERIA i s u se d w he n a n e ve nt o cc ur s w hi ch c an b e e xp an de d t o g iv em o r e i n f o r m a t i on , a n d a c o u nt e r i s r e q ui r e d t o b e m a i nt a i n ed f o r e a c h s u b -- c l a ss o f information.

    Cumulative counters

    T h i s t y p e o f c o u n t e r p r o v i d e s a r a w c o u n t . I t c o n t a i n s a n a d d i t i o n a l f i e l d :

    CUMULATED VALUE

    T h e a c c o u n t i n g a l g o r i t h m i s a s f o l l o w s :

    initialization:CUMULATED VALUE = 0

    e v e n t : a d d N t o CUMULATED VALUE

    collect:

    readCUMULATED VALUE

    reset CUMULATED VALUE = 0

    Value counters

    T h i s t y p e o f c o u n t e r p r o v i d e s a v e r a g e v a l u e s f r o m r a w c o u n t s o b t a i n e d b y i n t e r n a ls a m p l i n g ( t h e t i m e i n t e r v a l b e t w e e n t w o e v e n t s i s v a r i a b l e a n d i s n o t a c c e s s i b l e t ou s e r s ) . I t c a n a l s o p r o v i d e a m a x i m u m v a l u e .

    I t c o n t a i n s t h r e e a d d i t i o n a l f i e l d s :

    CUMULATED VALUE

    NUMBER OF SAMPLES

    MAX VALUE (if required)

  • 8/11/2019 Nortel Counters Description

    36/1041

    Introduction Nortel Networks Confidential1--6

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    T h e a c c o u n t i n g a l g o r i t h m i s a s f o l l o w s :

    initialization:

    CUMULATED VALUE = 0

    NUMBER OF SAMPLES = 0

    MAX v a l u e = r e f e r e n c e t h r e s h o l d ( i f r e q u i r e d )

    event:

    addN to CUMULATED VALUE

    add1 to NUMBER OF SAMPLES

    ifN > MAX VALUE, t h e n MAX VALUE =N ( i f r e q u i r e d )

    collect:

    read CUMULATED VALUE

    read NUMBER OF SAMPLES

    read MAX VALUE

    resetCUMULATED VALUE = 0

    resetNUMBER OF SAMPLES = 0

    resetMAX VALUE = r e f e r e n c e t h r e s h o l d

    Load counters

    T h i s t y p e o f c o u n t e r p r o v i d e s a v e r a g e v a l u e s f r o m r a w c o u n t s o b t a i n e d b y i n t e r n a ls a m p l i n g ( t h e t i m e i n t e r v a l b e t w e e n t w o e v e n t s i s v a r i a b l e a n d i s n o t a c c e s s i b l e t ou s e r s ) . I t c a n a l s o p r o v i d e a m a x i m u m v a l u e .

    I t c o n t a i n s f o u r a d d i t i o n a l f i e l d s :

    CUMULATED VALUE

    NUMBER OF SAMPLES

    MAX VALUE (if required)

    MIN/MAX FLAG

    T h e a c c o u n t i n g a l g o r i t h m i s a s f o l l o w s :

    initialization:

    C U M UL AT E D VA L U E = 0

    N UM BE R O F S A MP L ES = 0

    M IN o r M AX F L AG = 1

    E X TE R NA L S A M P LI N G P E R I OD = T 1

  • 8/11/2019 Nortel Counters Description

    37/1041

    IntroductionNortel Networks Confidential 1--7

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    event:

    a dd o r s ub tr a ct 1 t o/ f ro m VA LU E ( de pe nd in g o n m ax im um o r m in im umcount)

    o n e x t e r n a l s a m p l i n g p e r i o d T 1 e l a p s e :

    a dd 1 t o N U M BE R O F S A M PL E S

    collect:

    read CUMULATED VALUE

    r e a d N UM B E R O F S A MP L E S

    r e a d M A X VA L U E

    r e s et C U M UL AT E D VA L U E = 0 r e se t N U MB E R O F S A MP L E S = 0

    r e s et M A X VA L U E = r e f e r en c e t h r e s ho l d

    1.1.2.3 Counter names

    O n t op o f i t s Q 3 n am e, y ou c an a ss ig n a c us to mi ze d n am e t o a ny o bs er va ti on c ou nt era t t h e S D O l e v e l . T h i s c u s t o m i z e d n a m e i s d e f i n e d a t t h e S D O l e v e l a n d i s k e p tt h r o u g h S D O u p g r a d e s .

    All counters added to the SDO counter list during an upgrade can get a customized

    n am e a t u pg r ad e t im e. T he u pg ra de p r oc ed ur e g et s c us to mi ze d n am es f r om ad e d ic a t e d c o n f ig u r a ti o n f i l e ( / S D O /b a s e/ i n st a l l / c on f i g / sd o _ cn t r s _l i s t _F T. c f g )p r o v i d e d b y N o r t e l .

    T h i s f i l e i s a s e t o f l i n e s ( o n e p e r Q 3 n a m e t o c u s t o m i z e ) s h a r i n g t h e s a m e f o r m a t :< c ou nt e r Q 3 n a me > # < co un t er i d > < c ou n te r s ub i d> < o cc ur r e nc e i d > < t yp e o f counter>

    T o e n a b l e t h i s f e a t u r e :

    1 Click the Data Format tab on the SDO MMI

    2 Set the Counter name field to custom

    1.1.2.4 Number of counters

    A BSC can make a limited number of observations. Refer to the following table tok n o w a b o u t t h i s l i m i t a t i o n s p e r B S C t y p e a n d v e r s i o n .

    BSC type BSC version Number of distinctcounters Ids observed

    BSC memory threshold

    V12 200 900BSC 2G

    V15 350 1000

  • 8/11/2019 Nortel Counters Description

    38/1041

    Introduction Nortel Networks Confidential1--8

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    BSC type BSC memory thresholdNumber of distinctcounters Ids observed

    BSC version

    V14.3 300 1500BSC 3000

    V15 350 1500

    T w o m a j o r c o n s t r a i n t s m u s t b e t a k e n i n t o a c c o u n t w h e n r u n n i n g o b s e r v a t i o n s :

    t h e n u m b e r o f c o u n t e r I d s p e r o b s e r v a t i o n t y p e ,

    a t h r e s h o l d r e l a t e d t o t h e u s e o f B S C m e m o r y .

    Number of counter Ids per observation type

    F or e ac h o bs er va ti on t yp e ( ORT, O FS , O GS , O DI A G) , a m ax im um n um be r o f d i s t i n c t c o u n t e r I d s ( s c r e e n i n g s a r e i g n o r e d ) i s a l l o w e d .

    Use of BSC memory

    To e ns ur e c o rr e ct p e rf o r ma nc e , B S C m e mo r y u se m u st n o t e x c ee d a l i m it g i ve n b yt h e f o l l o w i n g f o r m u l a :

    C EL L_ OF S + C EL L_ OG S + ( NE IG H_ OG S + N EI GH _O FS )* nb _n ei gh +( TD MA cl a_ OG S + T DM Ac la _O FS )* nb _T DM A_ cl ass es < B SC m em or y

    THRESHOLDI f B S C m e m o r y u s e i s g r e a t e r t h a n t h i s t h r e s h o l d , a w a r n i n g m e s s a g e w i l l a s k y o ut o r e m o v e s o m e c o u n t e r s i n t h e b s c c o u n t e r l i s t .

    Name Meaning

    CE LL _O FS nu mber of cou nt er scr ee ni ngs ( co up le i d: su bi d) p er cel lo n O F S o b s e r v a t i o n

    CE LL _O GS nu mber of cou nt er scr ee ni ngs ( co up le i d: su bi d) p er cel lo n O G S o b s e r v a t i o n

    N EI GH _O FS n um be r o f c ou nt er sc re en in gs ( co up le i d: su bi d) p ern e i g h b o r i n g c e l l o n O F S o b s e r v a t i o n

    N EI GH _O GS n um be r o f c ou nt er sc re en in gs ( co up le i d: su bi d) p ern e i g h b o r i n g c e l l o n O G S o b s e r v a t i o n

    nb_neigh number of neighbor ing cell s per cell ( =32)

    T DM Ac la _O FS n um be r o f c ou nt er s cr e en in gs ( co up le i d: su bi d) p ert d m a o n O F S o b s e r v a t i o n

    T DM Ac la _O GS n um be r o f c ou nt er s cr e en in gs ( co up le i d: su bi d) p ert d m a o n O G S o b s e r v a t i o n

    n b_ TD MA_c lasses 2

  • 8/11/2019 Nortel Counters Description

    39/1041

    IntroductionNortel Networks Confidential 1--9

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1.1.3 Observation classes

    B S S o b s e r v a t i o n c o u n t e r s a r e c l a s s i f i e d a s f o l l o w s ( i n a l p h a b e t i c a l o r d e r ) :

    A interface

    Abis interface

    a l l o c a t i o n ( o f r a d i o r e s o u r c e s )

    a s s i g n m e n t ( o f d e d i c a t e d c h a n n e l s )

    ASCI (GSM--R feature)

    B S C e q u i p m e n t

    BSS/OMC--R linkhandover

    interference

    L a y e r 1 m a n a g e m e n t ( L 1 M )

    m o n i t o r i n g ( o f c o m m o n c o n t r o l c h a n n e l s )

    P C M l i n k

    r e l e a s e ( o f r e s o u r c e s )

    s e t u p ( o f c a l l s )

    S M S s e r v i c e

    1.1.4 Mobility Class Sensitivity CountersO n s o m e c o u n t e r s , t h i s f a c i l i t y p r o v i d e s t h e o p e r a t o r w i t h s t a t i s t i c s i n d e x e d b y t h eM S p o w e r c l a s s ( 2 W , 8 W o r 2 W a n d 8 W ) . T h i s m e a s u r e t h e Q o S b y t y p e o f a p p l ic a t i on ( t r a i n c o n t r o l , s h u n t ) . T h e o p e r at o r c a n t o g g l e b e t we e n i g n o r i n g / ta k i ngi n t o a c c o u n t t h e p o w e r c l a s s c r i t e r i u m a t t h e O M C - R . T o g e t s i g n i f i c a n t m e a s u r e s ,i t i s r e c o m m e n d e d t o :

    3 stop observation counters.

    4 toggle the power class criterium.

    5 start observation counters again.

  • 8/11/2019 Nortel Counters Description

    40/1041

    Introduction Nortel Networks Confidential1--10

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1.2 Observation counter incrementation principles and data

    flow diagram (DFD)

    1.2.1 Radio resource allocation

    1.2.1.1 SDCCH allocation request

    SDCCH allocation request

    SDCCH resource

    No

    No handover in--progressand TCH resource

    No

    sdcchRessourceFailure

    Yes sdcchAllocatedsdcchAveragedUsedallSdcchAllocatedTime (possibly)

    Yes tchFrAllocated (cause = Overflow)

    tchFrAveragedUsed (cause = Overflow)allTchFrAllocatedTime (possibly)

    available

    available

    1.2.1.2 TCH allocation request in primo-allocation

    TCH allocation request in primo--allocation

    TCH resource

    No

    SDCCH resource

    No

    tchFrRessourceFailure

    Yes

    Yes

    tchFrAllocated (cause = Primo--allocation)tchFrAveragedUsed (cause = Primo--allocation)

    allTchFrAllocatedTime (possibly)

    sdcchAllocatedsdcchAveragedUsedallSdcchAllocatedTime (possibly)

    available

    available

  • 8/11/2019 Nortel Counters Description

    41/1041

    IntroductionNortel Networks Confidential 1--11

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1.2.1.3 TCH allocation request for traffic

    Attempt of allocation

    TCH resourceavailable

    No

    Yes tchFr/HrAllocated (cause = TCH channel)tchFr/HrAveragedUsed (cause = TCH channel)allTchFrAllocatedTime (possibly)

    of a TCH

    Request can be queued

    No

    tchFr/HrResourceFailure

    YestchAverageQueueLength (cause highest priority or internal

    priority)

    Each time a queueingrequest is served

    (set from a queueto the TCH pool)

    tchFr/HrAllocated (cause = TCHchannel)

    tchFr/HrAveragedUsed (cause =TCH channel)

    allTchFrAllocatedTime (possibly)

    tchQueueingDuration

    tchAverageQueueLength (cause =

    highest priority or internal priority)

    tchQueueingExpiration (cause =highest priority or internal priority)tchAverageQueueLength (cause =highest priority or internal priority)tchQueueingDuration

    Each time a queueingrequest is extracted

    from a queue on timerexpiration

  • 8/11/2019 Nortel Counters Description

    42/1041

    Introduction Nortel Networks Confidential1--12

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1.2.2 Call setup

    C a l l s e t u p i s i n i t i a t e d b y t h e m o b i l e s ( M o b i l e O r i g i n a t i n g C a l l s e t u p ) o r t h e M S C( M o b i l e T e r m i n a t i n g C a l l s e t u p ) .

    I n t he s ec on d c as e, a p ag in g p r oc ed ur e p r ec ed es t he i mm ed ia te a ss ig nm en tprocedure.

  • 8/11/2019 Nortel Counters Description

    43/1041

    IntroductionNortel Networks Confidential 1--13

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    1.2.2.1 Immediate assignment procedure (normal completion)

    D a t a F l o w D i a g r a m : i m m e d i a t e a s s i g n m e n t p r o c e d u r e ( n o r m a l c o m p l e t i o n )

    Set timer TchnAck

    Reset timer TchnAck

    Set timer T3101

    Reset timer T3101

    MS BTS BSC MSCCHANNEL_REQUEST CHANNEL_REQUIRED

    1748

    1702

    1191/n (1)

    1730 (1)

    1606

    1607

    1744 (2)

    1746 (2)

    1609/2 (2)

    1611/2 (2)

    CHANNEL_ACTIVATE

    1749

    1192/n

    1629/0CHANNEL_ACTIVATE_ACK

    IMMEDIATE_ASSIGNMENT_COMMAND

    ESTABLISH_INDICATION

    1750

    1193/n1195 or 1196

    1108

    1502

    IMMEDIATE_ASSIGNMENT

    SABM(CM_SERVICE REQUEST)

    CONNECTION_REQUEST(L3_INFORMATION

    CM_SERVICE_REQUEST)

    CONNECTION_CONFIRM

    11051104/0START_MEASUREMENT_REQUEST

    START_MEASUREMENT_REQ_ACK

    DTAP (CM_SERVICE_ACCEPT)

    11071501DTAP (CM_SERVICE_ACCEPT)

    CM_SERVICE_ACCEPT

    ALERTING

    DTAP (ALERTING)

    DTAP (ALERTING)

    11081500

    (1) T h e f o l l o w i n g c o u n t e r s a r e i n c r e m e n t e d d e p e n d i n g o n t h e c a u s e v a l u e i n t h eC H A N N E L R E Q U I R E D m e s s a g e :

    1 1 9 1 c a u s e 0 0 0

  • 8/11/2019 Nortel Counters Description

    44/1041

    Introduction Nortel Networks Confidential1--14

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1 1 9 1 / 1 a n d 1 7 3 0 f o r c a u s e 0 0 1

    1 1 9 1 / 2 f o r c a u s e 0 1 0

    1 1 9 1 / 3 f o r c a u s e 0 1 1

    1 1 9 1 / 4 a n d 1 7 3 0 f o r c a u s e 1 0 0

    1 1 9 1 / 5 f o r c a u s e 1 0 1

    1 1 9 1 / 6 f o r c a u s e 1 1 0

    1 1 9 1 / 7 f o r c a u s e 1 1 1

    (2) S i n c e V 9 r e l e a s e s , t h e f o l l o w i n g m o d i f i c a t i o n s h a v e b e e n p e r f o r m e d :

    1606 i n s t e a d o f 1034

    1607 i n s t e a d o f 10351609 i n s t e a d o f 1051

    1611 i n s t e a d o f 1052

    (3) I f n o S DC CH i s a va il ab le , t h e B SC m ay t r y t o a ll oc at e a T CH i n s ig na li n g m od e.I n t h i s c a s e , t h e f o l l o w i n g c o u n t e r s a r e i n c r e m e n t e d :

    1744 , 1746, 1609/2, 1611/2

    L i s t o f t h e c o u n t e r s i n c r e m e n t e d d u r i n g t h i s p r o c e d u r e :

    Counternumber

    Counter name Function

    1104/0 sccpAllocated number of SCCP connections forSSN BSSMAP in the BSC

    1105 sccpAveragedUsedMoy/Max/Cum/Ech

    average number of SCCPconnections established

    1107 aInputMessage number of BSSAP messagesreceived by the BSC

    1108 aOutputMessage number of BSSAP messages sent bythe BSC

    1191/n[n= 0 to 7]

    channelRequestCauseXxx number of channel allocationrequests: Cause xxx

    1192/n[n= 0 to 7]

    immediateAssignmentSuccessCauseXxx

    number of successful immediateassignments: Cause xxx

    1193/n[n= 0 to 3]

    estabIndicSignallingCauseXxx

    number of ESTABLISH INDICATIONmessages in establishment phasereceived for mobile originating calls:Cause Xxx

    1195 estabIndicSigPhaseI number of ESTABLISH INDICATIONmessages in establishment phasereceived for Phase I mobiles

  • 8/11/2019 Nortel Counters Description

    45/1041

    IntroductionNortel Networks Confidential 1--15

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    Counternumber

    FunctionCounter name

    1196 estabIndicSigPhaseII number of ESTABLISH INDICATIONmessages in establishment phasereceived for Phase II mobiles

    1500 aTransparentUp number of DTAP messages sent bythe BSC to the MSC

    1501 aTransparentDown number of DTAP messages received

    1502 aNonTransparentUp number of BSSMAP messages sentby the BSC

    1606 sdcchAllocatedTrZone number of SDCCH allocated in thezone (concentric cell)

    1607 sdcchAveragedUsedTrZoneMoy/Max/Cum/Ech

    average number of SDCCHs used inthe inner or outer zone of the cell

    1609/2 tchFrAllocatedOverflowAllocationTrZone

    number of TCH/FR allocated in theinner or outer zone of the cellbecause of SDCCH unavailability

    1611/2 tchFrAveragedUsedOverflowAllocationTrZone

    Moy/Max/Cum/Ech

    average and maximum number ofTCH/FR used in the inner or outerzone of the cell because of SDCCH

    unavailability

    1629/0 channelActivateSignallingFullRate

    number of Full Rate channelsactivated for signaling

    1702 channelRequestExtended number of receipt of CHANNELREQUIRED message with a timingadvance greater than 63

    1730 pagingResponse number of responses to pagingrequests in the cell

    1744 tchFrAllocated

    ortchFrAllocatedTrZone

    number of TCH/FR or preempted

    PDTCH allocated in the cellornumber of TCH/FR or preemptedPDTCH allocated in the inneror outer zone of the concentric cell

    1746 tchFrAveragedUsedMoy/Max/Cum/EchortchFrAveragedUsedTrZoneMoy

    /Max/Cum/Ech

    average number of TCH/FR orpreempted PDTCH used in the celloraverage number of TCH/FR orpreempted PDTCH used in the inneror outer zone of the cell

  • 8/11/2019 Nortel Counters Description

    46/1041

    Introduction Nortel Networks Confidential1--16

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    Counternumber

    FunctionCounter name

    1748 channelRequest number of channel allocation requests

    1749 immediateAssignmentSuccess

    number of successful immediateassignments

    1750 estabIndicSignalling number of ESTABLISH INDICATIONmessages in establishment phasereceived

    1.2.2.2 Immediate assignment procedure with OTDI (normal completion)

    T h i s p r o c e d u r e u s e d t o e s t a b l i s h g r o u p c a l l s ( V C S o r V G C S ) i n c l u d e s O r i g i n a t o rT o D i s p a t c h e r I n f o r m a t i o n ( O T D I ) i n t h e s e t u p m e s s a g e .

  • 8/11/2019 Nortel Counters Description

    47/1041

    IntroductionNortel Networks Confidential 1--17

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    Set timer TchnAck

    Reset timer TchnAck

    Set timer T3101

    Reset timer T3101

    MS BTS BSC MSCCHANNEL_REQUEST CHANNEL_REQUIRED

    1748

    1702

    1191/n (1)

    1730 (1)

    1606

    1607

    1744 (2)

    1746 (2)

    1609/2 (2)

    1611/2 (2)

    CHANNEL_ACTIVATE

    1749

    1192/n

    1629/0CHANNEL_ACTIVATE_ACK

    IMMEDIATE_ASSIGNMENT_COMMAND

    est_ind(immediate_setup2(call Id,OTDI))

    1750

    1193/n

    1195 or 119611081502

    1722

    IMMEDIATE_ASSIGNMENT

    SABM(immediate_setup2(call ID,OTDI))

    CONNECTION_REQUEST(immediate_setup2, call Id,

    OTDI)

    CONNECTION_CONFIRM

    11051104/0START_MEASUREMENT_REQUEST

    START_MEASUREMENT_REQ_ACK

    DTAP (CM_SERVICE_ACCEPT)

    11071501DTAP (CM_SERVICE_ACCEPT)

    CM_SERVICE_ACCEPT

    ALERTING

    DTAP (ALERTING)

    DTAP (ALERTING)

    11081500

  • 8/11/2019 Nortel Counters Description

    48/1041

    Introduction Nortel Networks Confidential1--18

    PE/DCL/DD/0125411--9001--125

    Standard 15.107/EN July 2005 Copyright 2000--2005 Nortel Networks

    1.2.2.3 Paging procedure

    D at a F lo w D ia gr am : i mm ed ia te a ssi gn me nt : p ag in g p ro ce du re ( no rm alcompletion)

    MS BTS BSC MSCPAGING_REQUEST

    1108

    1502

    CONNECTION_REQUEST(PAGING_RESPONSE)

    Set timer TchnAck

    Reset timer TchnAck

    PAGING_COMMAND

    Set timer T3101

    Reset timer T3101

    CHANNEL_REQUIRED

    CHANNEL_ACTIVATE

    1629/0

    CHANNEL_ACTIVATE_ACK

    IMMEDIATE_ASSIGNMENT_COMMAND

    1749

    1192/n

    1107

    1503PAGING_COMMAND

    CHANNEL_REQUIRED

    174817021191/n (1)1730 (1)160616071744 (2)1746 (2)1609/2 (2)1611/2 (2)

    IMMEDIAT_ASSIGNMENT

    SABM (PAGING_RESPONSE)

    ESTABLISH_INDICATION

    CONNECTION_CONFIRM

    11051104START_MEASUREMENT_REQUEST

    START_MEASUREMENT_REQ_ACK

    DTAP (SETUP)

    11071501

    DTAP (SETUP)

    DTAP (ALARTING)

    SETUP

    ALERTING

    DTAP (ALARTING)

    11081500

    17501193/n1195 or 1196

  • 8/11/2019 Nortel Counters Description

    49/1041

    IntroductionNortel Networks Confidential 1--19

    Observation Counter DictionaryCopyright 2000--2005 Nortel Networks

    (1) T h e f o l l o w i n g c o u n t e r s a r e i n c r e m e n t e d d e p e n d i n g o n t h e c a u s e v a l u e i n t h e

    C H A N N E L R E Q U I R E D m e s s a g e :1 1 9 1 / 0 f o r c a u s e 0 0 0

    1 1 9 1 / 1 a n d 1 7 3 0 f o r c a u s e 0 0 1

    1 1 9 1 / 2 f o r c a u s e 0 1 0

    1 1 9 1 / 3 f o r c a u s e 0 1 1

    1 1 9 1 / 4 a n d 1 7 3 0 f o r c a u s e 1 0 0

    1 1 9 1 / 5 f o r c a u s e 1 0 1

    1 1 9 1 / 6 f o r c a u s e 1 1 0

    1 1 9 1 / 7 f o r c a u s e 1 1 1

    (2) S i n c e V 9 r e l e a s e s , t h e f o l l o w i n g m o d i f i c a t i o n s h a v e b e e n p e r f o r m e d :

    1606 i n s t e a d o f 1034

    1607 i n s t e a d o f 1035

    1609 i n s t e a d o f 1051

    1611 i n s t e a d o f 1052

    (3) I f n o S DC CH i s a va il ab le , t he B SC m ay t r y t o a ll oc at e a T CH i n s ig na li ng m od e.I n t h i s c a s e , t h e f o l l o w i n g c o u n t e r s a r e i n c r e m e n t e d :

    1744, 1746, 1609/2, 1611/2

    L i s t o f t h e c o u n t e r s i n c r e m e n t e d d u r i n g t h i s p r o c e d u r e :

    Counternumber

    Counter name Function

    1104/0 sccpAllocated number of SCCP connections forSSN BSSMAP in the BSC

    1105 sccpAveragedUsedMoy/Max/Cum/Ech

    average number of SCCPconnections established

    1107 aInputMessage number of BSSAP messagesreceived by the BSC

    1108 aOutputMessage number of BSSAP messages sent bythe BSC

    1191/n[n= 0 to 7]

    channelRequestCauseXxx number of channel allocationrequests: Cause xxx

    1192/n[n= 0 to 7]

    immediateAssignmentSucces


Recommended