4
R PAGE 1 OF 4 CALL 1-800-999-3600 SUBJ ECT TO CHANGE W THOUT NOTCE" " ALLDMENSONS AND DESGN CRTERA PROJ ECT I ON T HI RD ANGLE F I LE NO. 177 - 474 REV. 4 ( DI MENSI ONS I N I NCHES) DI MENSI ONS I N MI LL I MET RES L 596 TP-820716-001. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. CONSULT WITH DIEBOLD INSTALLATION/SERVICE PLAN VIEW FRONT ELEVATION SIDE ELEVATION 794 ") 4 1 (31 ") 2 1 ( 13 ") 4 1 (30 768 ") 2 1 ( 13 795 " ) 8 3 ( 4 111 " ) 16 5 ( 31 906 " ) 16 11 ( 35 HEIGHT DEPTH A B E TOP FUNCTION KEY C D ADVANCED FUNCTION DISPENSER HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF BEZEL TOP OF MONITOR RECEIPT PRINTER CARD READER ( 0") 0 ") 16 11 (45 1161mm ") 16 13 (7 198mm CONSUMER ACCESS DIMENSIONS ") 8 3 (42 1077mm ") 4 3 (5 146mm ") 8 3 (4 111mm ") 16 9 (34 878mm ") 16 1 (27 688mm ") 16 9 (34 878mm ") 8 3 (4 111mm fi 794 ") 4 1 (31 324 ") 2 1 (18 470 ") 4 3 (12 ON PAGE 2 OF 4) (SEE "CAUTION" LABEL CODE SCANNER OPTIONAL CONSUMER BAR 1490 " ) 16 11 ( 58 1471 " ) 4 3 ( 19 " ) 16 15 ( 57 0 mm T O 76 mm ( 0 " T O 3 " ) LEVEL I NG 795 ") 8 3 (4 111 ") 16 5 (31 906 ") 16 11 (35 238 ") 16 9 (8 217 ") 8 3 (13 340 ") 8 3 (9 1490 " ) 16 11 ( 58 795 ") 8 3 (4 111 ") 16 5 (31 906 ") 16 11 (35 1490 " ) 16 11 ( 58 0 mm T O 76 mm ( 0 " T O 3 " ) LEVEL I NG 676 " ) 16 5 ( 31 795 " ) 8 5 ( 26 1471 " ) 4 3 ( 19 " ) 16 15 ( 57 794 ") 4 1 (31 A B D E C ") SHORT SAFE 2 1 WITH 13mm ( FRONT LOAD - 4 HIGH OPTEVA 720 ADVANCED FUNCTION LOBBY ATM
Transcript
Page 1: OPTEVA 720 ADVANCED FUNCTION LOBBY ATM ... - Diebold … · opteva 720 advanced function lobby atm. note acceptor) operations. depository module) and ena (enhanced note acceptor)

R

PA

GE 1 O

F 4

CALL 1-800-999-3600

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

PR

OJE

CTIO

N

THIR

D A

NG

LE

FIL

E N

O. 177-4

74 R

EV. 4

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

SL596

TP-820716-001.

PLEASE SEE PLANNING AND SITE PREPARATION GUIDE

BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.

CONSULT WITH DIEBOLD INSTALLATION/SERVICE

PLAN VIEW

FRONT ELEVATIONSIDE ELEVATION

794

")41

(31

")21(

13

")41

(30

768")2

1(

13

795

")8

3(4

111

")16

5(3

1

906

")16

11

(35

HEIGHT DEPTH

A

B

E

TOP FUNCTION KEY

C

D ADVANCED FUNCTION DISPENSER

HEIGHT - FROM BOTTOM OF SAFE

DEPTH - FROM FRONT EDGE OF BEZEL

TOP OF MONITOR

RECEIPT PRINTER

CARD READER

( 0")

0

")1611(45

1161mm

")1613(7

198mm

CONSUMER ACCESS DIMENSIONS

")83(42

1077mm

")43(5

146mm

")83(4

111mm

")169(34

878mm

")161(27

688mm

")169(34

878mm

")83(4

111mm

fi

794

")41

(31

324

")21

(18

470

")43

(12

ON PAGE 2 OF 4)

(SEE "CAUTION" LABEL

CODE SCANNER

OPTIONAL CONSUMER BAR

1490

")16

11

(581471

")4

3 (

19

")16

15

(57

0m

m T

O 7

6m

m (0"

TO 3") L

EV

ELIN

G

795")8

3(4

111

")165

(31

906

")1611

(35

238

")169

(8

217

")83

(13

340

")83

(9

1490

")16

11

(58

795

")83

(4

111")16

5(31

906

")1611

(35

1490

")16

11

(58

0m

m T

O 7

6m

m (0"

TO 3") L

EV

ELIN

G

676

")16

5(3

1795

")8

5(2

61471

")4

3 (

19

")16

15

(57

794

")41

(31

A

B

D

E

C

") SHORT SAFE21 WITH 13mm (

FRONT LOAD - 4 HIGH

OPTEVA 720 ADVANCED FUNCTION LOBBY ATM

Page 2: OPTEVA 720 ADVANCED FUNCTION LOBBY ATM ... - Diebold … · opteva 720 advanced function lobby atm. note acceptor) operations. depository module) and ena (enhanced note acceptor)

NOTE ACCEPTOR) OPERATIONS.

DEPOSITORY MODULE) AND ENA (ENHANCED NOTE ACCEPTOR) OR IDM AND BNA (BULK

RAPID PROCESSING - SYSTEMS CONFIGURED FOR SIMULTANEOUS IDM (INTELLIGENT

1,875 BTU/HR RAPID PROCESSING

2,094 BTU/HR RAPID PROCESSING

TRANSACTION IN PROGRESS

RAPID PROCESSING550 WATTS 614 WATTS

PA

GE 2 O

F 4

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

FIL

E N

O. 177-4

74 R

EV. 4

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

BACK ELEVATION SIDE ELEVATION

1

2

3

4

EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.

NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR

5

NOTE: SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW.

GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY

WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT

THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE.

200-240 VAC (–10%) SERVICE, DISCONNECT AT 10 AMPERES

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES

OR OPTIONAL ELECTRONIC LOCK.

GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY

HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A

12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR

THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,

AND RATE-OF-RISE HEAT SENSOR.

BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH, ALARM SHUNTING SWITCH,

THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE

PHYSICAL SECURITY

ALARM PROTECTION

SIGNAL CABLE RUN CONSTRAINTS

ELECTRICAL EQUIPMENT CABLE RUN.

OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS

AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.

POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE

TYPE OF ELECTRICAL RUN

LIGHTING FIXTURES

FLUORESCENT, NEON OR INCANDESCENT

ELECTRICAL EQUIPMENT

UNSHIELDED POWER LINE OR

CONDUIT

WITH SIGNAL CABLES IN GROUNDED

POWER LINES IN GROUNDED CONDUIT

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

127mm (5") 127mm (5") 127mm (5")

127mm (5") 305mm (1’-0") 610mm (2’-0")

")2164mm (2 152mm (6") 305mm (1’-0")

")16330mm (1 76mm (3") 152mm (6")

SIGNAL CABLE INSTALLATION CONSTRAINTS:

644 kg (1,420 LBS.)

SAFE LOCATION

OPERATING ENVIRONMENT:

20 TO 55% AT 38” C (100” F)

20 TO 80% AT 32” C (90” F),

RELATIVE HUMIDITY (NON-CONDENSING)

10” C TO 38” C (50” F TO 100” F)

WEIGHT OF UNIT:

POWER USAGE:

MACHINE STATUS

IDLE (NO TRANSACTION)

OR BULK NOTE) IN PROGRESS

TRANSACTION (DISPENSE

190 WATTS

285 WATTS

229 WATTS

349 WATTS

1 2

CONFIGURATION:

1

2

1

2

PRINTER, 80mm THERMAL RECEIPT PRINTER, STANDARD DEPOSITORY AND 5 HIGH AFD.

PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL

80mm THERMAL RECEIPT PRINTER, IDM, 5 HIGH AFD, AND BULK NOTE ACCEPTOR.

PROCESSOR, SVD LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL PRINTER,

THE ATM, AND THE TYPE OF TRANSACTION THE ATM IS PERFORMING.

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN

648 BTU/HR IDLE

1,190 BTU/HR BULK NOTE ACCEPTING

971 BTU/HR DISPENSING

781 BTU/HR IDLE

HEAT OUTPUT CONFIGURATION:

POWER REQUIREMENTS:

200-240 VAC (–10%) AT 50 (–1%) Hz, SINGLE-PHASE

200-240 VAC (–10%) AT 50 (–1%) Hz, SINGLE-PHASE

100-127 VAC (+6%, -10%) AT 60 (–1%) Hz, SINGLE-PHASE

100-127 VAC (+6%, -10%) AT 50 (–1%) Hz, SINGLE-PHASE

(OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE

SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT

POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A

GROUNDED CONDUIT

SIGNAL CABLES ENCLOSED IN

ELECTRICAL EQUIPMENT WITH

UNSHIELDED POWER LINES OR

WITH TAMPER SWITCH.

BOX (ALL BY OWNER’S E.C.). DIEBOLD TO PROVIDE FLAT COVER

") DEEP JUNCTI0N 81JUNCTION BOX TO 102mm (4") SQ. X 54mm (2

25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET

CONDUIT AND JUNCTION BOX REQUIREMENTS

") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY.81102mm (4") S.Q. X 54mm (2

") METAL CONDUIT FROM 43CASH DISPENSER, OWNER’S E.C. TO RUN 19mm (

WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO

RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE.

") 43") LIQUID TIGHT FLEX METAL CONDUIT OR 19mm (4

3OWNER’S E.C. TO RUN 19mm (

PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA.

CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE

CAUTION LABEL

(SEE POWER REQUIREMENTS).

MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER’S E.C.)

WITHIN 2210mm (87") OF SIDE CONNECTING PLATE. BOTTOM CONNECTION

") DEEP JUNCTION BOX WITH RECEPTACLE81102mm (4") SQ. X 54mm (2

") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 4319mm (

SEPARATION FROM OTHER CABLES

LENGTH 2184mm (86") FROM SIDE OF UNIT.

SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD

OWNER’S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY

CORD

POWER

1

2

4

1

5

3

4

")21(

13")4

1(30

768

")21(

13

794

")41

(31

0m

m T

O 7

6m

m (0"

TO 3") L

EV

ELIN

G

1490 ")8

5(5

8

1471

")4

3 (

19

")16

15

(57

379

")87

(14

378

")21

(1

38

")1615

(14

795

")165

(31

240

")165

(13

339

")167

(9

906

")1611

(35

")1611

(2

68

")85

(25

651")16

15(2

75

1032 ")8

5(4

0

27

")16

5(5

51405

")2

1(1

39

")16

1(1

THE BACK ELEVATION AS SHOWN

OF THIS OPTEVA MODEL MAY DIFFER FROM

BACK PANEL DESIGN ON EARLIER VERSIONS

NOTE:

Page 3: OPTEVA 720 ADVANCED FUNCTION LOBBY ATM ... - Diebold … · opteva 720 advanced function lobby atm. note acceptor) operations. depository module) and ena (enhanced note acceptor)

R

PA

GE 3 O

F 4

CALL 1-800-999-3600

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-4

74 R

EV. 4

RECOMMENDED SERVICE AREA

MINIMUM SERVICE AREA

MUST ENTER UNIT IN THIS AREA

ALL ELECTRICAL AND DATA CABLES

BUILDING CONDITIONS.

TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL

RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE

IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE

SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO

SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND

NOTE:

PLAN VIEW-SINGLE UNIT

(RECOMMENDED SERVICE AREA)

(MINIMUM SERVICE AREA)

285

")43

(6

171

")41

(31

794

")41

(11

1250

")41

(49

(2")

51

(2")

51321

")16

1(1

7433

(6")

152

")8

5(1

2

")16

9(4

71208

")16

11

(359

06

(2")

51

2165 ")4

1(8

5

(2")

51

(2")

51

285

")43

(6

171

")41

(31

794

")41

(11

1250

")41

(49

321

")16

1(1

7433

(6")

152

")8

5(1

2

")16

9(3

8979

")16

11

(359

06

(2")

51

1936 ")4

1(7

6

(2")

51

(2")

51

321

")16

1(1

7433

(6")

152

")8

5(1

2

")16

9(3

8979

")16

11

(359

06

(2")

51

1936 ")4

1(7

6

285

")43

(6

171

")41

(31

794

")43

(6

171

")41

(31

794

")43

(6

171

")41

(31

794

")41

(11

682

")83

(22

568

(38")

965

(38")

965

")1613

(26

3180

")163

(125

(MINIMUM SERVICE AREA)

PLAN ADJACENT UNITS

PLAN VIEW-SINGLE UNIT

fi

") SHORT SAFE21 WITH 13mm (

FRONT LOAD - 4 HIGH

OPTEVA 720 ADVANCED FUNCTION LOBBY ATM

Page 4: OPTEVA 720 ADVANCED FUNCTION LOBBY ATM ... - Diebold … · opteva 720 advanced function lobby atm. note acceptor) operations. depository module) and ena (enhanced note acceptor)

PA

GE 4 O

F 4

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

FIL

E N

O. 177-4

74 R

EV. 4

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).

")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER’S INSTALLER) 4319mm (

WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)

IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR

") DIA. X 203mm (8" MIN.) DEEP HOLES43OWNER’S INSTALLER TO DRILL (4) 19mm (

(8")

203

MIN.

(4")

102

MIN.

203mm (8")

MINIMUM HOLE DEPTH

102mm (4")

MINIMUM CONCRETE DEPTH

VIEW "A" VIEW "B"

1

22

1

2 2

1 1

327

")163

(1

30

")163

(16

411

")87

(12

220

")8

7(6

175

")4

3(1

5400

")16

11

(8

795

")16

5(3

1

35

")83

(1

35

")21

(27

698

")83

(1

768

")41

(30

378

")16

15

(143

79

")2

1(1

38

")8

7(1

4

")8

3(1

35

") DIA. LEVELING LEG HOLES169(4) 14mm (1-

2-

SA

FE

SAFE

DISPENSER.

OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH

DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE

FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH

SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER

CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE

ENTERING THE CASH DISPENSER PASS THROUGH THE POWER

A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES

ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH

ALARM CABLES (SIDE ENTRY)

") DIA. HOLE FOR8129mm (1

(SIDE ENTRY)

AND DATA CABLES

OPENING FOR POWER CORD

POWER CABLE PLATE

NOTES:FOR ADDED SECURITY:

ANCHORING THE ATM TO CONCRETE FLOORS:

ANCHORING THE ATM TO WOOD FLOORING:

YOUR INSTALLATION.

ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR

IT IS RECOMMENDED THAT THE ATM SAFE BE SECURED TO THE FLOOR WITH

ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.

EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS

ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS

(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.

IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm

") ANCHOR BOLT THAT43WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (

IT IS RECOMMENDED THAT THE ATM BE ANCHORED TO CONCRETE FLOORS

OF CONCRETE FLOORS.

NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT

") THICK. IT IS IMPORTANT TO41STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (

REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL

CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED

THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING

CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT

ATM’S INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODED BEAMS

").21BE AT LEAST 13mm (

PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST

A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO

OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO

METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS

ATM’S INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED

ANCHORING THE ATM TO STEEL FLOORS:

(4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES

PLAN/SECTION SAFE FLOOR

(SEE NOTE)

CABLE ENTRY OPENING

CABLE ENTRY NOTE:98

")16

9(2

3598

")8

7(3


Recommended