Mizuho Vascular Doppler SystemsIntraoperative essentials for neurosurgical and vascular procedures
© Mizuho America DO04 Rev. 7.14.14
Mizuho America, Inc. 30057 Ahern Avenue Union City, CA 94587 800 699 2547 mizuho.com
Ordering Information
8 MHz Doppler Probe (108260)•Packagedfourtoabox•Steriledisposable•55mmworkinglength, 160mm overall•Straightdesign,3mmtip
20 MHz Doppler Probe (07-150-07)•Packagedfourtoabox•Steriledisposable•105mmworkinglength, 275mm overall•Bayoneted,2mmtip
20 MHz Doppler Probe, Slim Handle (07-150-10)•Packagedfourtoabox•Steriledisposable•115mmworkinglength, 233mm overall•Bayoneted,2mmtip
8 MHz Doppler Transceiver with A/C (07-150-08)Size:6.5”x10”x4”(165mmx254mmx101mm),nom.Weight:2.6lbs.,(1.18kg),nom.Frequency: 8 MHzPower:8AAAlkalineBatteriesorA/C to D/C4hours,min.(standbymode,fullvolume)
8 MHz Kelly Endonasal Probe (138210)•Packagedfourtoabox•Steriledisposable•131mmworkinglength, 265mm overall•Bayoneted,2mmtip•Last10mmoftipbentat 10degrees
20 MHz Doppler Micro Probe (07-150-12)•Packagedfourtoabox•Steriledisposable113mmworkinglength, 231mm overall•Bayoneted,0.8mmultrafinetip
8 MHz Doppler Transceiver (108910) Size:4.25”x3.75”x5.35”(105mmx95mmx135mm),nom.Weight:1.4lbs.,(0.6kg),nom.Frequency: 8 MHzPower:8AAAlkalineBatteries10hours,nom.(standbymode, fullvolume)
20 MHz Doppler Transceiver with A/C (07-150-20 )Size:6.5”x10”x4”(165mmx254mmx101mm),nom.Weight:2.6lbs.,(1.18kg),nom.Frequency: 20 MHzPower:8AAAlkalineBatteriesorA/C to D/C4hours,min.(standbymode,fullvolume)
20 MHz Doppler Transceiver (07-150-02) Size:4.25”x3.75”x5.35”(105mmx95mmx135mm),nom.Weight:1.4lbs.,(0.6kg),nom.Frequency: 20MHzPower:8AAAlkalineBatteries10hours,nom.(standbymode,fullvolume)
20 MHz Doppler Micro Probe, Slim Handle (108650)•Packagedfourtoabox•Steriledisposable•74mmworkinglength,200mmoverall•Bayoneted,0.8mmultrafinetip
208Mizuho Vascular Doppler SystemsIntraoperative essentials for neurosurgical and vascular procedures
20 MHz Doppler Transceiver with A/C
Mizuhooffersaportable,easy-to-use,andaccuratemodalityforevaluatingbloodflowintraoperatively.Twosystemsoperatingattwodifferentfrequencies,8MHzand20MHz,provideaudiobloodflowdetectionatdifferentdepthsofpenetration.Eachsystemcomeswithasetoftransceiversandsteriledisposableprobesdesignedforspecificsurgicalprocedures.
8 MHz System2cmdepthpenetrationdependingonthedensityofsurroundingtissueandbone
Indications •Locatescarotidarteryintranssphenoidalprocedures•Allowstechnicalverificationofanastomosesandendarterectomies•Supportsassessmentofflapviability•EvaluatesAVfistulasandEC-ICBypass•Verifiesgraftandshuntpatency
Transceivers•AvailablewithA/CtoD/Cconnectionandbatteryonly
Probes•Packaged4inabox•Sterile,Disposable•StraightandBayonetdesign•2mmor3mmtip
Clinical BenefitQuicklyassessaneurysmclipplacementandconfirmaneurysmocclusionClinical Benefit Minimizetheriskofinternalcarotidarteryinjuryduringtranssphenoidalsurgery
20 MHz System1cmdepthpenetrationdependingonthedensityofsurroundingtissueandbone
Indications •LocatesfeederarteryinAVM•Locatesvesselsnotedonangiogram•Determinescompletenessofaneurysmclipping•Determinespatencyofparentvesselpostaneurysmclipping•Validatespatencyofmicrovascularanastomoses•Confirmspatencyofmajorvenoussinuses
Transceivers•AvailablewithA/CtoD/Cconnectionandbatteryonly
Probes•Packaged4inabox•Sterile,Disposable•Bayonetdesignonly•2mmor0.8mmtip
8 MHz Doppler Transceivers with A/C