www.flexiforce.com manual pass doors switch kit INSTALLATION / MAINTENANCE © All rights reserved. FlexiForce®, 2010 OSE-PDSK-IND/RES GB
Transcript
Page 1: OSE PDSK IND/RES

www.flexiforce.com

manual

pass doors switch kitINSTALLATION / MAINTENANCE © All rights reserved. FlexiForce®, 2010

OSE-PDSK-IND/RES

GB

Page 2: OSE PDSK IND/RES

www.flexiforce.com

manualATTENTION! GENERAL WARNINGS!

To install, use and maintain this pass doors switch kit safely, a number of precautions must be taken. For the safety of all concerned pay heed to the warnings and instructions given below! If in doubt, contact your supplier.

99 This manual has been written for use by experienced fitters and as such is not suitable for d.i.y. purposes or for use by trainee fitters.

99 This manual describes the installation of certain hardware set components. Be sure to supplement this manual if needed with instructions for any additional components not described in this manual.

99 Before starting, read this manual carefully!99 Certain components may be sharp or have jagged edges. As such you are advised to wear safety gloves.99 During tensioning, springs can exert large forces. Work carefully. Use the proper equipment. Ensure that you are standing in a steady position.

99 Ensure that there is sufficient light during installation. Remove obstacles and dirt. Make sure that there is no one else present other than the fitters. Other people (children!) may get in the way or endanger themselves during the installation.

TERMS AND CONDITIONSThe general terms and conditions of delivery and payment issued by the Metaalunie and designated as METAALUNIE CONDITIONS are fully applicable to all our quotations, contracts and their implementation. We expressly reject all other terms and conditions. On request we will send you a copy of these terms and conditions free of charge. A copy may also be downloaded from our website www.flexiforce.nl.

CONTACTFlexiForce Group B.V.P.O. Box 373770 AA BarneveldThe NetherlandsTel. +31-(0)[email protected]

GB

FF-MANUAL OSE-PDSK-IND/RES

Page 3: OSE PDSK IND/RES

www.flexiforce.com

manual

OSE-SCB1OSE-SCB1

Drill 6.5 mmDrill 19.0 mm

(-)(+)

13 mm

13 mm

CONTENT OF PACKAGING

GB

FF-MANUAL OSE-PDSK-IND/RES

FF-MANUAL OSE-PDSK-IND

FF-MANUAL OSE-PDSK-RES

TOOLS REQUIRED FOR CORRECT AND RAPID ASSEMBLY

1,5 m

200 mm200 mm

1 m

1 m (x4)

750 mm (x4)

OSE-SCB1OSE-MPDS (5 m) OSE-LAD2

OSE-1113926

OSE-1113704W

OSE-MPDS (5 m) 5 mOSE-LAD1

Page 4: OSE PDSK IND/RES

www.flexiforce.com

manualFig. a

Fig. 4Fig. 3

Fig. 5 Fig. 6

Fig. 2Fig. 1

Ø 19mm

Ø 19mm

GB

ASSEMBLY of OSE-PDSK-IND/RES

FF-MANUAL OSE-PDSK-IND/RES

Page 5: OSE PDSK IND/RES

manual

www.flexiforce.comFF-MANUAL OSE-PDSK-IND/RES

Fig. 7 Fig. 8

Fig. 10

Fig. 11

Fig. 9

Fig. 12FF-MANUAL OSE-PDSK-RES FF-MANUAL OSE-PDSK-RES

www.flexiforce.com

GB

ASSEMBLY of OSE-PDSK-IND/RES

FF-MANUAL OSE-PDSK-IND

1006B

1062M

Page 6: OSE PDSK IND/RES

manual

www.flexiforce.comwww.flexiforce.com

Fig. 13

Remarks:

GB

FF-MANUAL OSE-PDSK-IND/RES

FF-MANUAL OSE-PDSK-RES

Page 7: OSE PDSK IND/RES

manualw

www.flexiforce.comFF-MANUAL OSE-PDSK-IND/RES

Wiring instructions to most common CDO controls by brand

GB

Mtec

MFZ

control unit UST2 L

Terminal block X5 connector J6 (remove bridge)

control unit CS300

Terminal block X3 connectors 1 & 2 (remove bridge)

control unit UST1 KL

Terminal block K2 connector J10 (remove bridge)

control unit CS100

Terminal block X13 connectors 1 & 2 (remove bridge)

control unit AS100

Terminal block X3 connectors 4 & 5 (remove bridge)

control unit AS210B

Terminal block X3 connectors 14 & 15 (remove bridge)

Dalmaticmini std. V7E

Long terminal strip connectors 28 & 29

GAROGAS210

Long terminal strip connectors 16 & 17

GfATS970

Terminal block X3 connectors 3.1 & 3.2


Recommended