+ All Categories
Home > Documents > Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Date post: 30-Dec-2016
Category:
Upload: lamnhu
View: 214 times
Download: 1 times
Share this document with a friend
30
Overview of ENERGY STAR for Multifamily High Rise Requirements
Transcript
Page 1: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Overview of ENERGY STAR forMultifamily High Rise

Requirements

Page 2: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Agenda

• Development of the MFHR Requirements• Role of the ENERGY STAR MFHR Developer

Partner• Role of the Licensed Professional• Earning the ENERGY STAR for MFHR Buildings

– Performance Path– Prescriptive Path– Submittal Requirements

2

Page 3: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Development of MFHR Requirements

Page 4: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Multifamily High-Rise vs. Other Residential Buildings

4

Page 5: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

The Reference Standard

ASHRAE 90.1-2007•Minimum requirements for the energy-efficient design of high-rise multifamily buildings

Appendix G•Protocols for generating an energy performance rating for buildings that exceed the requirements of ASHRAE 90.1-2007

Program Standard•LEED Mid-Rise•Enterprise Green Communities

5

Page 6: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Technical Requirements Developed

• Set Energy Performance Target for achieving ENERGY STAR

• Developed modeling guidelines• Developed testing and verification

protocols• Developed tools to facilitate program

participation

6

Page 7: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Piloting ENERGY STAR MFHR Guidelines (2005 – 2011)

Casey Building - 44%

City Row – Projected 11/2010

Las Colinas- 25%Trinity Bluff - 34%

Brookhaven - 25%

Newark Genesis - 28%Parker Hall - 21%

1212 MLK- 20%

Myrtle Avenue - 21%

Intervale Green - 33%

The Cedars- 30%

Atlantic Ave. Apts.- 20%

Atlantic Ave. Residences 1- 22%

The Eltona- 32%

Project Under Development

(1)

(9)(1)

(1)

(2)

(2)

(1)

Atlantic Ave. Residences 2 and 3 - 26%

Page 8: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Participant Roles and Expectations

Page 9: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

9

ENERGY STAR MFHR Developer Partner • Partner with ENERGY STAR• Submit MFHR Project Application for

each building/project• Engage a licensed professional to

validate submitted documents• Commit to benchmarking building in

Portfolio Manager

Page 10: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

10

Role of Licensed Professional

• Work with project design team• Coordinate modeling of Baseline and Proposed

building OR guide design team through Prescriptive Path requirements

• Validate plan review to ensure final design meets requirements and necessary details are included in bid specifications

• Validate on-site inspections during construction to ensure measures are installed as specified

• Submit required documentation to EPA

Page 11: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Earning the ENERGY STAR

Page 12: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Pathways to ENERGY STAR

12

Mandatory Requirements (Prerequisites)

Performance Path Prescriptive Path

Testing and Verification

ENERGY STAR

Benchmarking

Page 13: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Common Requirements for Performance and Prescriptive

Paths

Page 14: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

14

Meeting the Prerequisites

Page 15: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Testing and Verification Protocols

• Mandatory requirements for the inspection, testing and verification of components related to the building’s energy performance.

• The intent of the protocols is to verify that – the construction documents & final building include all

Prerequisites.– measures used to achieve the Performance levels predicted

by the model have been installed and perform as modeled.– all measures specified by the Prescriptive Path have been

installed.

• Changes to the initial design noted during inspections must be reflected in a revised model and submitted as the As-Built model.

15

Page 16: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Testing and Verification Worksheets

• Mandatory Excel-based worksheets that document the results of plan reviews, inspections, verification, and performance testing.– Provide inspection worksheets that can be used in the field

that follow the Testing and Verification Protocols, but are organized for the convenience of the site inspector.

– Provide a central file to store building information relevant to all members of the design team: architect, energy modeler, site inspector, project manager, plan reviewer, etc.

– Must be submitted once prior to construction to document results of the plan review and once after construction is complete, to document the results of testing and verification.

16

Page 17: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Photo Template

• This Word-based template was designed so that pictures used to provide photo-documentation required by the T&V Protocols could be easily formatted and consistently reported.

• Photo documentation must be submitted to EPA at the end of construction as part of the As-Built Submittal

• The Photo Template need only be submitted for the licensed professional’s first three buildings that participate in the Program.

17

Page 18: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Performance Path

Page 19: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Performance Path Requirements

• Meet program Prerequisites

• Meet Performance Target– 15% better than ASHRAE 90.1-

2007 as defined by Appendix G and Simulation Guidelines

• Third-party verification and performance testing throughout construction

• Commit to Benchmarking in Portfolio Manager for at least two years

19

Page 20: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Performance Path Work FlowDesign

Construction

Post Construction

Page 21: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Prescriptive Path

Page 22: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Prescriptive Path Requirements

• Install climate specific prescriptive requirements that meet or exceed Prerequisites– Approximately equivalent to

15% better than ASHRAE 90.1-2007, but no modeling

• Third-party verification and performance testing throughout construction

• Commit to benchmarking in Portfolio Manager for at least two years

22

Page 23: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Prescriptive Path Work FlowDesign

Construction

Post -Construction

Page 24: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Program Submittals

Page 25: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

MFHR Program Submittals

25

Page 26: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

Proposed Building Submittal

• Proposed Building Reporting Summary (Performance Path Only)

• Testing and Verification Worksheets

• MFHR Submittal Validation Form

26

Page 27: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

As-Built Building Submittal

• As-Built Building Reporting Summary (Performance Path Only)

• Testing and Verification Worksheets

• Photo Template

• MFHR Submittal Validation Form

27

Page 28: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

License Professional’s Guide and Submittal Validation Form

• More information on submittals can be found in the Licensed Professional’s Guide to Earning the ENERGY STAR for MFHR Buildings document at www.energystar.gov/mfhr

28

Page 29: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

ENERGY STAR MFHR Webinar Series

• Introduction to Earning the ENERGY STAR for Multifamily High Rise Buildings

• Introduction to the Performance Path• Introduction to the Prescriptive Path• Using the ENERGY STAR Simulation Guidelines • Using the Performance Path Calculator• Introduction to the Testing and Verification

Protocols• Using the T&V Worksheets

29

Page 30: Overview of ENERGY STAR for Multifamily High Rise Buildings ...

More Information

ENERGY STAR for MFHR www.energystar.gov/mfhr

Email question to:[email protected]

30


Recommended