PERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www.intertek.com This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program Client Homedics USA, LLC 3000 North Ponac Trail Commerce Township, MI 48390-2720 Project No. G103639641 Sample Product Air Purifier Model Purifier Unit AP-T40 w/ Filter AP-T40FL Identification No. COL1809181136-001 Date Received September 18, 2018 Condition New/Good Production or Prototype Production Procedural Engineer Nicholas Unger Reviewer Lee Moomaw Dates Tested 09/24/2018 to 10/12/2018 Report Date 10/12/2018 Test Temperature and Relative Humidity 19-21°C & 10-25% RH Standard Non-standardized Test Method: Microbial Reduction Rate Test Test Method Summary: The test unit was placed in a test chamber and a microbial suspension was aspirated into the chamber. The test unit was turned on high setting. Air samples were taken from the test chamber once the unit was turned on, and then at 15-minute intervals over a period of 2 hours. The process was then repeated without the test unit in the chamber to provide the natural decay results. Summary of Results: Test Parameter Mold Fungus Bacteria Virus Test Parameter Aspergillus niger (ATCC 6275) Penicillium citrinum (ATCC 9849) Escherichia coli (ATCC 11229) Coliphage φX174 (Item # 124425) Filter w/ UV Reduction 99.9% 99.9% 99.9% 99.9% UV only Reduction 94% 97% 99% 98% Test Performed by: Report Approved by: Nicholas Unger Lee Moomaw Project Engineer Project Engineer Columbus Office Columbus Office
Transcript
Page 1: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

PERFORMANCE TEST REPORT

103639641COL-002

1717 Arlingate Lane Columbus, OH 43228

Telephone: 614-279-8090 Facsimile: 614-279-4642

www.intertek.com

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program

Client Homedics USA, LLC

3000 North Pontiac Trail Commerce Township, MI 48390-2720

Project No. G103639641 Sample Product Air Purifier

Model Purifier Unit AP-T40 w/ Filter AP-T40FL Identification No. COL1809181136-001 Date Received September 18, 2018

Condition New/Good Production or

Prototype Production

Procedural Engineer Nicholas Unger Reviewer Lee Moomaw

Dates Tested 09/24/2018 to 10/12/2018 Report Date 10/12/2018

Test Temperature and Relative Humidity 19-21°C & 10-25% RH

Standard Non-standardized Test Method: Microbial Reduction Rate Test Test Method Summary: The test unit was placed in a test chamber and a microbial suspension was aspirated into the chamber. The test unit was turned on high setting. Air samples were taken from the test chamber once the unit was turned on, and then at 15-minute intervals over a period of 2 hours. The process was then repeated without the test unit in the chamber to provide the natural decay results. Summary of Results:

Test Parameter

Mold Fungus Bacteria Virus Test

Parameter Aspergillus niger

(ATCC 6275) Penicillium citrinum

(ATCC 9849) Escherichia coli (ATCC 11229)

Coliphage φX174 (Item # 124425)

Filter w/ UV Reduction 99.9% 99.9% 99.9% 99.9%

UV only Reduction 94% 97% 99% 98%

Test Performed by: Report Approved by:

Nicholas Unger Lee Moomaw Project Engineer Project Engineer Columbus Office Columbus Office

Page 2: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

September 12, 2018 Deepa Mani HoMedics USA, LLC 3000 North Pontiac Trail Commerce Township, MI 48390-2720 USA Dear Ms. Mani: We appreciate the opportunity to be of service to you. Please find enclosed one copy of Intertek Report No. 103639734CRT-001 covering AHAM AC-1 and EPA Energy Star program, tests performed on your behalf. Model(s) Tested: AP-T40 If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact me. Sincerely,

Mike Podoliak Technician I Energy Efficiency Group

Page 3: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

An independent organization testing for safety, performance, and certification.

This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

PVT-AC-005, 5/06/02

Test Report

3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Project No. G103639734 Date: September 12, 2018

REPORT NO. 103639734CRT-001

RENDERED TO:

HoMedics USA, LLC 3000 North Pontiac Trail

Commerce Township, MI 48390-2720

Report Scope: This testing is for AHAM AC-1 and EPA Energy Star program for

Room Air Cleaners. Limitation Statement: The test data and results contained in this report are provided for

client information and evaluation. Authorization: The tests were authorized by signed Quote No. QU-00911540

dated August 22, 2018. Standards Used: ANSI/AHAM AC-1-2015 entitled, "Association of Home Appliance

Manufacturers Method for Measuring Performance of Portable Household Electric Room Air Cleaners" and IEC 62301 Ed. 2 entitled, “Household Electrical Appliances – Measurement of Standby Power”

Sample Description: One proto-type unit of model AP-T40 was supplied by the client

and received on August 23, 2018. The filters were supplied by the client and received on September 7, 2018.

Date of Tests: September 11, 2018

Page 4: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

Report No. 103639734CRT-001 September 12, 2018 Page 3 of 6

Test Method: Tests were performed in accordance with ANSI/AHAM AC-1-2015 entitled ""Association of Home Appliance Manufacturers Method for Measuring Performance of Portable Household Electric Room Air Cleaners". This standard method has defined limits of measurability. The practical limits of measurability are: Dust 10 to 400 CADR, Tobacco smoke 10 to 450 CADR and Pollen 25 to 450 CADR. The statistical validity of test results outside of the stated practical limits is questionable and unevaluated. Clean Air Delivery Rates (CADR's) were determined using Tobacco Smoke, AC Fine Test Dust, and Paper Mulberry Pollen. Additional requirements for energy taken from IEC 62301 Ed. 2 entitled, “Household Electrical Appliances – Measurement of Standby Power”. Monitored particle size ranges for the three particulates were as follows: Smoke - 0.10-1.0 microns; Dust - 0.5-3 microns; Pollen - 5-11 microns. Test Equipment List:

Equipment Used Model Number Intertek Control # Cal. Due Date Date Cal. Performed

Laser Aerosol Spectrometer 3340 D708 10/12/18 10/12/17

Aerodynamic Particle Sizer 3321 A-261 10/10/18 10/10/17

Fluidized Bed Aerosol Generator 3400 --

Temperature/Humidity Sensor HMW30YB T680 10/04/18 10/04/17

Power Analyzer WT210 G065 10/04/18 10/04/17

Page 5: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

Report No. 103639734CRT-001 September 12, 2018 Page 4 of 6

Device Under Test Description The device tested for this report was Model Number AP-T40 Air Cleaner. The following device settings were used during testing: Speed 3 Highest, UV light ON, Ionizer ON

AP-T40

AP-T40 Nameplate

Control Panel Results of Performance Tests:

Model/Configuration Test

Particulate Natural

Decay Rate CADR

(FT3/Min) CADR STDEV.

Power (Watts)

AP-T40, Unit 1, 1808231040-001, Speed 3 Highest, UV Light ON, Ionizer ON, 120 Volts, 60 Hertz

Smoke 0.00263 159.2 0.5 79.0

Dust 0.00678 162.0 0.5 79.8

Pollen 0.11370 166.7 7.9 78.8

Conclusion: The results reported are within the limits of measurability of the ANSI/AHAM AC-1-2015 "Association of Home Appliance Manufacturers Method for Measuring Performance of Portable Household Electric Room Air Cleaners" Test Method.

Page 6: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

Report No. 103639734CRT-001 September 12, 2018 Page 5 of 6

Operating Power Testing: Test Sample Information Manufacturer/Organization

Name Model

Number Serial Number Nameplate Voltage

Nameplate Frequency

Hz Nameplate

Watts

HoMedics USA, LLC AP-T40 NA 120 60 72

Test Criteria

Test Voltage Test Frequency

Ambient Test Temperature

°F

Ambient Humidity

%RH 120v +/- 1 60Hz +/- 1Hz 70°F +/- 5°F 40% +/- 5%

Test Results

Test Sample Test Voltage

Test Frequency

Ambient Test

Temperature °F

Ambient Humidity

%RH Dust

CADR Watts Dust

CADR/Watt

1 119.9 60 69 41 162.0 79.8 2.0 Conclusion: Qualifying air cleaners must have a minimum 50 CADR (Dust) and CADR/watts must be ≥ 2 (Dust). These results illustrate that this sample does meet the Energy Star Program performance requirements.

Page 7: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

Report No. 103639734CRT-001 September 12, 2018 Page 6 of 6

Standby Power Testing: Test Criteria – IEC 62301

Test Voltage Test Frequency

Total Harmonic Distortion of the Electricity Supply

System

Ambient Test Temperature

°F 115v +/- 1% 60Hz +/- 1% ≤ 2% 73.4°F +/- 9°F

Test Results

Test Sample Test Voltage

Test Frequency

Total Harmonic Distortion of the Electricity Supply

System

Ambient Test Temperature

°F

Standby Power Watts

1 115.2 60 0.20% 70.1 0.7 Conclusion: Minimum Standby Power Requirement is < 2 Watts. The results illustrated in the Standby Power Data shows that this unit meets the criteria.

Report Reviewed By: Report Completed By:

Sural Labha Engineer Energy Efficiency Group

Michael T. Podoliak Technician I Energy Efficiency

Page 8: PERFORMANCE TEST REPORTPERFORMANCE TEST REPORT 103639641COL-002 1717 Arlingate Lane Columbus, OH 43228 Telephone: 614-279-8090 Facsimile: 614-279-4642 www .intertek com This report

LMS TECHNOLOGIES, INC. 6423 Cecilia Circle, Bloomington, MN 55439

(952) 918-9060, Fax: (952) 918-9061

Test Date: Requested by: HoMedics, IncModel No.: AP-T40 Version 2 HoMedics, IncTest Type: Fractional EfficiencyTest Aerosol : KCl, Neutralized 5212

Unit

Velocity Low (56 cfm)

Medium (114 cm)

High (145 cfm)

�P ("H2O) 0.081 0.208 0.296

Size Range (�m)

0.3-0.5 99.981 99.975 99.9710.5-0.7 99.985 99.979 99.9760.7-1.0 99.987 99.985 99.9841.0-2.0 99.993 99.993 99.9942.0-3.0 99.996 99.996 99.9973.0-5.0 99.999 99.998 99.9995.0-10.0 100.000 100.000 100.000

F eff = Fractional EfficiencyC up = Particle Concentration Upstream of FilterC down =Particle Concentration Downstream of Filter

September 6, 2018

Fractional Efficiency(%)

AP-T40

Manufactured by:

LMS #:Description: Minipleated HEPA

0

20

40

60

80

100

0.1 1 10

)%( ycneiciffE lanoitcarF

Particle Diameter (�m)

Fractional Efficiency versus Particle Diameter

TEST SUPERVISOREMILE TADROS

ENGINEERING APPROVALK. C. KWOK, PH. D. ______ F-011