+ All Categories
Home > Documents > Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from...

Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from...

Date post: 01-Mar-2021
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
30
Lil’ a with laser trapped 6 He Peter Müller
Transcript
Page 1: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Lil’ a with laser trapped 6He

Peter Müller

Page 2: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

6He Collaboration

2

P. Mueller, A. Leredde, T.P. O’Connor, K. Bailey Physics Division, Argonne National Laboratory

A. Garcia, M. Sternberg, F. Wauters, D. Zumwalt, R. Hong,

Y. Bagdasarova, D. Storm, H.E. Svanson, G. Harper CENPA, University of Washington

X. Flechard, E. Liennard

LPC Caen

O. Naviliat-Cuncic NSCL, Michigan State University

PhD, Postdoc

$ PM DOE Early Career Research Grant, DOE CENPA, LPC $

Page 3: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Weak Interaction Studies: b-n Angular Correlations

6He

6Li

t1/2=0.808 sec

100% b

0+

1+

Qb=3.510 MeV

-1.0

-0.5

0.0

0.5

1.0

Co

rre

latio

n C

oe

f. a

1.00.80.60.40.20.0

T

A

V

S

-50

-40

-30

-20

-10

0

10

20

a(e

xp

) - a

(SM

)

x1

0-3

1.00.80.60.40.20.0

Fermi fraction

6He n

21Na

32Ar

38mK

21Na

Atom Trap Ion Trap

b

bn

b

b

bnb E

mb

E

paEN )cos(1),(

Page 4: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

4

The Case for 6He

β- decay, pure Gamow-Teller decay to g.s. 6Li

Suitable half-life and Q-value

Produced and transferred with high yield (noble gas)

Simple nuclear and atomic structure

Small branch of ~10-6 for 6He → α+d

Current experiments searching for tensor cpl. in b decay

Page 5: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Beta-Decay Study with Laser Trapped 6He

Recoil time-of-flight spectrum

(MC simulation)

• ~5x109 6He/s production yield • trapping rate ~1x103 6He/s

• ~0.1% statistics in ~8 weeks beam time

Atom trap properties • Highly selective capture • No RF fields or space charge • Low temperature sample (<mK) • Tight spatial confinement (< 100mm)

250 300 350 400 450

a = -1/3

Co

un

ts

Time of Flight, ns

a = +1/3

b-Detector

Trapped 6He

6Li recoil ion detector

Page 6: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Production of 6He @ CENPA

6He produced using the 7Li(d,3He)6He reaction on molten lithium

Deuteron currents up to 10 μA @ 18 MeV using tandem Van de Graaff accelerator at CENPA/UW

6He extracted to vacuum and transported to low background environment

collimator

cooling

electrical

isolation

lithium cup

heating

temperature

sensor

beam current

measurements

David Zumwalt

Page 7: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

6He Production and Transfer

7

A. Knecht et al., NIM A 660, 43 (2011)

Page 8: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Precision 6He Lifetime

8

6He decay curve

6He half-life

ft-value

Compare with ab-initio calculations of |MGT| to obtain gA in nuclear medium

A. Knecht et al., PRL 108, 122502 (2012) A. Knecht et al., PRC 86, 035506 (2012)

Page 9: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

9

Atomic Energy Levels of Helium

2 3S1

1 1S0

389 nm

IS: 43 GHz

1083 nm

IS: 30GHz

2 3P0,1,2

19.8 eV,

e-collision in discharge

3 3P0,1,2

He discharge

metastable

He energy level diagram

3 3S1

706 nm

IS: 600 MHz

Page 10: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

10

Atom Trapping of 6He

Atom Trap Setup

706 nm

1083 nm

@ source 5x109 s-1

Capt. efficiency = 2x10-7

@ trap 1000 s-1

6He Rates

Image

706 nm

23S1

11S0

2 3P2

3 3S1

Trap

1083 nm

He level scheme

Page 11: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Helium MOT

Setup @ CENPA

11

Page 12: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

MOT Imaging

12

• On-line MOT imaging

• 2 cameras for x/y/z control

• Trap diameter < 200 mm

• Trap stability < 10 mm *

Page 13: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

MOT to MOT transfer

13

MOT1 MOT2

• Reduce background from un-trapped 6He through diff. pumping

• Separate MOT functions capture vs. detection

• Optical “push” beam

• Transverse cooling

• ~40% transfer in 15 ms

Page 14: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

14

Beta and Recoil Ion Detectors

MCP

2 kV/cm

electrode structure

Atom cloud

Beryllium window

Proportional counter

Scintillator

Page 15: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Beta Detector System

15

Ran Hong

125 mm thick

Page 16: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Electrode System

16

• Deflect recoil ions (1.4 keV max.) onto 8 cm dia. MCP

• Variable, uniform electric field with 0.05%

relative stability and accuracy

• 1.5 – 2.0 kV/cm -> 80 – 99% coll. eff.

Yelena Bagdasarova

Page 17: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Electrode, MCP and HV Supply

17

• Stacked HV supplies • Control each electrode separately • Enable variable field geometries

Page 18: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Recoil Ion Detector

18

Xavier Flechard, Etienne Liennard

MCPs (micro channel plates)

Delay line anodes

On test flange with calibration mask

Digital readout of signals, FPGA processing (LPC FASTER DAQ system)

Page 19: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Recoil Ion Detector

19

Position calibration with mask, Na+ beam

• DAQ system for beta and recoil detectors works

• MCP efficiency 52 % (70%) • MCP uniformity 95.5 – 99.8% • Timing resolution ~100 ps • Position resolution ~100 mm • Position reconstruction ~ 1 mm

Need to do • In situ calibration with 6He BG • Timing calibration with 4He

Photo-ions (337 nm pulsed N2 laser)

Page 20: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

4He trap diagnostics with MCP

20

He* + X -> He + X+ + e-

He* + He* -> He + He+ + e-

t (ms)

ms

dtx (ns)

dt y

(ns)

Page 21: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

MCP Image of Trapped 6He

21

dtx (ns)

dt y

(ns)

8 cm MCP diameter

Page 22: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Results: First coincidences

DAMOP | Madison, WI | 06/05/2014

22

• 75 6He/s in MOT 2

• ~0.15 Hz trapped 6He

• ~0.15 Hz background (untrapped 6He)

Page 23: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Systematic Uncertainties

23

• Detailed MC simulation • Geant4 for beta tracking and detector response • COMSOL for E-field calculation, recoil ion tracking

Page 24: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Outlook

Short term

Install recirculating discharge source and guide beam

Aim for initial ~1% statistics (300k coincidences)

– 1 Hz coincidence rate, ~ 1 week

Compare with numerical simulations

Medium term

Upgrade trap / detector

– Improve discharge, recirculation, trap and transfer efficiency

– Multilayer MWPC for tracking

High statistics (0.1%) runs

– 10 Hz coincidence rate, ~ 8 weeks

Longer term

- Lil’ b at 10-3: beta spectrometer (PxR, CRES, traps, …)

- Lil’ a at 10-4: shake-off electrons, dipole traps, large MCPs, …

24

Page 25: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

6He Collaboration

25

P. Mueller, A. Leredde, T.P. O’Connor, K. Bailey Physics Division, Argonne National Laboratory

A. Garcia, M. Sternberg, F. Wauters, D. Zumwalt, R. Hong,

Y. Bagdasarova, D. Storm, H.E. Svanson, G. Harper CENPA, University of Washington

X. Flechard, E. Liennard

LPC Caen

O. Naviliat-Cuncic NSCL, Michigan State University

PhD, Postdoc

$ PM DOE Early Career Research Grant, DOE CENPA, LPC $

Page 26: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Limits with 0.1% 6He Experiment

26

90% C.L.

Page 27: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

The “Classic” 6He Experiment

27

C.H. Johnson, F. Pleasonton, T.A. Carlson, Phys.Rev. 1963

a = - 0.3308(30)

Measure 6Li recoil energy spectrum

with radiative correction from F. Glueck, Nucl. Phys A, 628, 493 (1998)

Page 28: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Systematic Uncertainty Estimates

da x 10-3

Trap position stability 10 mm 0.15

Electric field stability 4x10-4 0.15

MCP timing resolution 100 ps (200 ns) 0.15

MCP efficiency calibration rel. 0.04%

30 mm 0.15

Beta detector calibration 0.30

0.42 (0.13%)

Need more detailed simulations on E-field distortions, beta detector response and beta backscattering

– Calibration with 6He background gas

– Photoionization of 4He

Study different range for beta scattering parameters in GEANT4

– Few % backscattering events, need to understand to rel. ~ 5%

– Tracking in MWPC for fiducial cuts

28

Page 29: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

Beta Detector System

29

Scintillator energy calibration, 207Bi

9% dE/E

• MWPC 94% efficiency • New double-layer frames for position

resolution + angle under construction • Be window leads to 150 keV loss +

large angle straggling • Explore other window materials

Page 30: Peter Müller - Solvay InstitutesMOT to MOT transfer 13 MOT1 MOT2 • Reduce background from un-trapped 6He through diff. pumping • Separate MOT functions capture vs. detection •

First coincidence signals

30

October 2013


Recommended