Slide 2 Energy Automation
Siemens Pipeline Control
Pipelines – Lifelines for our Supply of Raw Materials
The entire global economy depends on a safe and reliable supply of oil & gas. Extracted resources must be transported over long distances. Pipelines are the most economical way. Pipelines are the best solution in terms of reliability of supply. High safety against environmental pollution.
Slide 3 Energy Automation
Siemens Pipeline Control
The Way of Oil & Gas
Gas Oil
Exploration
Production
Processing
Transport
Transport/
Distribution
Storage
Transport
Refinery
Transport / Storage
Scope of Siemens
Pipeline Control Storage
Slide 4 Energy Automation
Siemens Pipeline Control
Customers Expectations
Pipeline operators have clear expectations of
pipeline-automations systems:
System-wide, reliable monitoring and control
Support for the dispatcher in controlling the pipeline
system
Increased system availability
Increased system safety
Open for future expansions
Integration into the existing system landscape
Utilization of existing communications media and
pathways.
Connection to pipeline integrity management
system
Reduction in operating and maintenance costs
Slide 5 Energy Automation
Siemens Pipeline Control
Requirements of Pipeline Automation Systems
Compressor control
Pump and valve control
Temperature, pressure and flow-rate measurements
Measurements of the quality of the transported media
Powerful SCADA functionality
Leak detection and localization
Energy management
Forecasting functions
Remote configuration and maintenance (remote control)
Open, object-oriented data model
Open architecture
Safety functions
Integration of existing systems
Slide 6 Energy Automation
Siemens Pipeline Control
Typical Structure of a Pipeline Automation System
Slide 7 Energy Automation
Siemens Pipeline Control
The Complete Solution from Siemens
Characteristics:
Use of standard components Scalability: from entry-level to complex pipeline system Pipeline object database Utilization of different communications media Support of standard protocols Availability of many protocols Redundancy capability Comprehensive functions for monitoring and controlling Remote configuration and maintenance Energy data management for forecasting, procurement and optimization Open for expanded applications
Slide 9 Energy Automation
Power System control centers Spectrum PowerCC
SICAM 200
SINAUT Spectrum
Spectrum Power TG
Station control & automation SICAM PAS
SICAM 1703
Protection/Power Quality / Bay Control SIPROTEC
Reyrolle
BC 1703 ACP
AM 1703
SIMEAS
Communications & networking SAT 100
Modems
PLC
RTU’s SICAM 1703 SICAM eRTU / miniRTU TG 805 / TG 5700
Tools DIGSI
SICAM Toolbox ll
IMM
Energy Market Mgmt. EMM
FDWH
Prophet
AMIS
Siemens Pipeline Control
Siemens Strong Products and Brands at all Levels
Slide 10 Energy Automation
Siemens Pipeline Control
Our Portfolio of Solutions
The following functions support you in the
operation of your pipeline:
Complete utilization range from local
operation to a central control station
Complete SCADA functionality
Archiving
Automatic log and report generation
Web functionality
Communications and data interchange with
partners, such as other market participants
Advanced systems management functions
such as leak detection and localization
Slide 11 Energy Automation
Safety and availability
Long-term safety and economy
Turnkey or step-by-step installation
Uniformity
Expert consultancy based on extensive process
experience
Autonomous, scalable functional areas
Reduced maintenance costs through remote
diagnostic functions
Concrete benefits for you:
Siemens Pipeline Control
One System - Many Advantages
Slide 13 Energy Automation
Siemens Pipeline Control
References: Adria Vienna Pipeline (AWP)
LEGEND: TAZ = TAL Terminal Station
PS = Pump Station
RS = Pressure Control Station
AZ1 = Terminal Station Lannach
US1 = Terminal Station Schwechat
WZ01 = Maintenance Centre Klagenfurt
WZ02 = Maintenance Centre Klagenfurt
Geographical Information
Slide 14 Energy Automation
Type
Crude oil pipeline from
Würmlach to Schwechat
Technical Data
Ø 18"
Length: 420 km
Flow rate max. 1.650 m³/h
Tasks
Telecontrol and automation
Communication
Protection
Local MMI
Data Range
approx. 40.000 DP
Used Systems
69 SK 1703
28 AK 1703
1 AM 1703
16 MMK 220
59 DRS-Light
Technical Information
Siemens Pipeline Control
References: Adria Vienna Pipeline (AWP)
Slide 15 Energy Automation
Integrated system:
protection
automation
telecontrol
communication
Security redundancy
No additional failsafe system
Back-up communication over ISDN
remote maintenance system
Siemens Pipeline Control
References: Adria Vienna Pipeline (AWP)
Special Features
Slide 16 Energy Automation
Control Centre Würmlach
Control Centre Vendor: Pichler Engineering
Ethernet-TCP/IP
AK 1703
TG, PS1
SATNET-LAN
SK 1703
SAT 250
TS2
SATNET-LAN
SK 1703
SAT 250
PS2 PS11
Radio
12 Pump Stations
2 Pressure Control Stations
2 Terminal Stations
1 Valve Station
Siemens Pipeline Control
References: Adria Vienna Pipeline (AWP)
Overview
Slide 17 Energy Automation
SK 1703
SK 1703 SK 1703 AK 1703
AM 1703 AM 1703 AM 1703 ELIN DRS-Light
Protection
FO-Bus Protection
FO-Bus AM 1703
HART
SK 1703
SAT-LAN
Pressure Controllers
H&B/Protronic PS
Main
Pump 1
Tank Gauging
Rosemount
to Frontend A to Frontend B
ELIN DRS-Light
Protection
AM 1703
Main
Pump 2
MMI
SAT 250
Details of a Pump Station
Siemens Pipeline Control
References: Adria Vienna Pipeline (AWP)
Slide 18 Energy Automation
Geographical Information
Siemens Pipeline Control
References: Telecontrol System for OMV
Slide 19 Energy Automation
Type
Gas Pipelines
Gas Storage
Technical Data
Ø 200 … 1050 mm
Total length in Austria: 1.450
km
Tasks
Tele control and automation
Communication
Back-up Control Centre
Service & Maintenance
Data Range
8.000 DP
Used Systems, approx.
75 SK 1703
4 AK 1703
220 MK 1703
7 AMC 1703
20 PCM
2 DMS 120
58 WT 101
1 SAT 250 SCALA
Technical Information
Siemens Pipeline Control
References: Telecontrol System for OMV
Slide 20 Energy Automation
Redundant communication over ISDN
Decentralised front-ends (redundant)
IEC 60870-5-104
Remote Maintenance
Coupling to station control systems (vendors:
Bernecker&Rainer, Siemens, Entronic, ABB, Bopp&Reuther,
Instromet) with modbus protocol
Priorisation of station data
Siemens Pipeline Control
References: Telecontrol System for OMV
Special Features
Slide 21 Energy Automation
RADIO
30x SK
1703
TAG
Ethernet-TCP/IP
Baumgarten
AK 1703 AK 1703
10x SK 1703,
200x µK 1703
HAG
WT
PCM
WAG,
Penta
West
3x SK 1703 Sierndorf
WT/
PCM
WT
Control Centre
Floridotower Control Centre
PSI
SAT 250 SCALA
Back-up System
10x SK 1703,
4x AMC 1703
Schoenkirchen/
Reyersdorf Zentralgasstation
Auersthal
AK 1703 AK 1703
Schoenkirchen
-Reyersdorf
OMV I OMV II NORD S-GAS
9x SK 1703
5x µK 1703
2x AMC 1703 3x SK 1703
3x SK 1703
1x AMC 1703 4x SK 1703
Gas Storage
Thann
Overview
Siemens Pipeline Control
References: Telecontrol System for OMV
Slide 22 Energy Automation
ISDN
Ethernet-TCP/IP
ZGST
Auersthal Baumgarten
AK 1703 AK 1703
Control Centre Floridotower/Vienna SAT 250 SCALA
Back-up System
Penta West 2
PCM PCM PCM PCM PCM PCM
SK 1703 AMC 1703 AMC 1703 AMC 1703 SK 1703 SK 1703
Oberkappel Kopfing Andorf Wippenham Mauerkirchen Ueberackern
ISDN-
Modem
Enzesfeld
Rapottenstein
Rainbach
WAG Oberkappel
Kirchberg
Großgoetfritz
Anreit
AMC 1703
Bad Leonfelden
ISDN ISDN-
Modem
ISDN-
Modem
ISDN-
Modem
PSI PSI
WAG - West Austria Gas Pipeline
Siemens Pipeline Control
References: Telecontrol System for OMV
Slide 23 Energy Automation
SK 1703 SK 1703
PCM
Front-Ends
Entronic Entronic
Entronic
~
µK 1703 µK 1703
approx. 110 gas storage wells StationControl
System
µK 1703 µK 1703
11. TH
Modem
16x µK 1703
copper wire
Gas storage Schönkirchen-Reyersdorf
Siemens Pipeline Control
References: Telecontrol System for OMV
Slide 25 Energy Automation
Automation &
HMI
Protection
Telecontrol
Energy-
management
SCADA
Data
Communication
Siemens Pipeline Control
Tasks
Slide 26 Energy Automation
Pump stations - Compressor stations - Valve stations - Terminal
stations - Gas storages
SICAM 1703 SICAM 200
+
++ redundant configurations ++ high reliable ++
modular ++ user friendly ++ IEC61131 ++ remote
management ++ scaleable +++ cutting edge-HMI ++
connectivity
Siemens Pipeline Control
Automations & Human Machine Interface
Slide 27 Energy Automation
Gas stations – Valve stations – Gas distribution network –
Frontends
SICAM 1703
++ flexible communication ++ redundant
configurations ++ high reliable ++ modular ++ user
friendly ++ IEC61131 ++ remote management ++
IEC60870-5-10x ++
D
P
Siemens Pipeline Control
Telecontrol
Slide 28 Energy Automation
Dispatching and control centers for gas transport and distribution
networks
RU
SCADA-Server SCADA-Client
SICAM 200
++ redundancy ++ extremly scaleable ++
Windows&Unix ++ cutting-edge, userfriendly HMI ++
powerful SCADA functions ++ connectivity ++ web
technology ++ Oracle/SQL-interface ++ TASE.2 ++
video surveillance
Additionals: leak detection, batch tracking, simulation
Siemens Pipeline Control
SCADA Systems
Slide 29 Energy Automation
Oil& Gas stations and pipelines
++ Solutions for every automation and communication
demand ++ network managment ++ redundancy ++
integration to SCADA
SAT 120 DMS
Digital Multiplexing System
Radiolink systems Video Surveillance
Network Management
Networking
PDH/SDH systems
GSM/UMTS
Siemens Pipeline Control
Communication