PNMT 1
PNMT - GENERAL
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A
PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK
MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORTHAUL RADIO TRANSMISSION NETWORK.
PNMT IS DESIGNED AS AN ONSITE MAINTENANCE
TOOL TO BE USED BY THE FIELD ENGINEERS AND
TECHNICIANS. IT CONNECTS DIRECTLY TO THE LA
PORT OF THE PASOLINK IDU. PNMT CAN BE USED
TO MONITOR LOCAL / REMOTE EQUIPMENTSTATUS AND PROVIDES CONTROL CAPABILITIES
SIMILAR TO THOSE AVAILABLE IN PNMS.
PNMT IS ALSO USED TO DOWN LOAD THE SYSTEM
AND CONFIGURATION FILES TO THE PM CARD AND
UPGRADE THE SOFTWARE IN THE IDU
WHEN CONNECTED TO AN IDU PNMT CANMONITOR NOT ONLY THE LOCAL EQUIPMENT BUT
ANY REMOTE NETWORK ELEMENT UNDER THE
CONTROL OF THE CENTRAL PM CARD.
TO USE THE PNMT, PM CARD SHOULD BE
MOUNTED IN THE IDUs.
7/18/2019 PNMT V4 Modified.ppt
2/41
NECITR-YTC
ART-SEP/03 V02
PNMT 2
FUNCTIONS
MICROSOFT WINDOWS 98/NT/200/XP WORKSTATION GRAPHICAL USER INTERFACE
ONE HOP LINK DISPLAY ON THE PNMT SCREEN
COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE PM CARDS
COMMUNICATE WITH REMOTE PM CARDS ON THE SAME NETWORK
TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE PM CARDS
SEVERAL LEVELS OF LOGIN / LOGOUT
EVENT LOGGING WINDOW
PERFORMANCE MONITORING FUNCTION WINDOW
LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION
LOCAL/REMOTE PM CARD CONFIGURATION MANAGEMENT
LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE
7/18/2019 PNMT V4 Modified.ppt
3/41
NECITR-YTC
ART-SEP/03 V02
PNMT 3
PNMT COMMUNICATION INTERFACECOMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT
LA PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND
CONSISTS OF A DB15 CONNECTOR. LA PORT CONNECT THE
PM CARD IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT
COMMUNICATION PORT OF THE PNMT COMPUTER.
PROPERTIES OF THE LA PORT ARE AS FOLLOWS:
PORT CONFIGURATION RS-232
CONNECTOR TYPE D-SUB 15 (FEMALE)
BITS PER SECOND RATEUP TO 19200
LA PORT
7/18/2019 PNMT V4 Modified.ppt
4/41
NECITR-YTC
ART-SEP/03 V02
PNMT 4
HARDWARE/SOFTWARE CONFIGURATION
RECOMMENDED PNMT MOBILE PC CONFIGURATION
LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)CPU: PENTIUM-400 OR HIGHER
RAM: 128 MB OR MORE
HDD: 2 GB OR MORE
FDD: 3.5INCH
CD-ROM: 8 x OR HIGHER
INTEGRATED SOUND CARD AND SPEAKER
OPERATING SYSTEM
WINDOWS XP (ENGLISH VERSION) WITH SP1 OR HIGHER
WINDOWS 98 (ENGLISH VERSION)WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WITH SP 6.0 OR HIGHER
WINDOWS 2000 (ENGLISH VERSION) WITH SP3 OR HIGHER
ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD-DISK
AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED
WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS
OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM
SOFTWARE CONFIGURATION
APPLICATION PROGRAM
NEC PNMT SOFTWARE
IE 5.0 OR HIGHER
ACROBAT READER
7/18/2019 PNMT V4 Modified.ppt
5/41
NECITR-YTC
ART-SEP/03 V02
PNMT 5
START UP
AFTER CONNECTING TO THE PASOLINK
EQUIPMENT TRIES TO ACQUIRE DATA FROM
THE LOCAL EQUIPMENT AND THE REMOTE
EQUIPMENT TO DISPLAY ON THE LINK
SUMMARY WINDOW
DOUBLE CLICK ON THE PNMT SHORTCUT
ICON ON THE DESKTOP OR CLICK ONSTART>>PROGRAM>>PNMT>>PNMT
PNMT PROGRAM STARTUP AND
TRIES TO GET CONNECTED TO
PASOLINK EQUIPMENT USING THE
DIAL-UP CONNECTION PNMT
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE
From the Control Panel select Phone
and Modem Options. Add a Standard
19200 bps Modem and assign it to theCOM1 port ( or the COM port to be
used)
Create a Dial-up connection using the
above standard modem and name it
as pnmt
PREPARATION
Install the NEC PNMT software
See PNMT Install Manual for details
7/18/2019 PNMT V4 Modified.ppt
6/41
NECITR-YTC
ART-SEP/03 V02
PNMT 6
SHUT DOWN
IN THE DIALOG BOX
THAT OPENS CLICK
YES
TO EXIT THE PNMT PROGRAM
CLICK ON EXIT IN THE SYSTEM
DROPDOWN MENU AND CLICK YES.
THE SCREEN INDICATES NOW PNMT
SHUTDOWN. IT WILL TAKE FEW MINUTES TO
SHUTDOWN
IF YOU HAVE NOT LOGIN FIRST THE
EXIT MENU CANNOT BE SELECTED.
7/18/2019 PNMT V4 Modified.ppt
7/41
NECITR-YTC
ART-SEP/03 V02
PNMT 7
PNMT MAIN SCREEN
PNMT WINDOW
MENU BAR
LINK SUMMARY WINDOW
COMMON TOOL BAR
NE-SPECIFIC MENU ITEMS
NE-SPECIFIC DATA
TAB SELECTION FOR
OTHER EQUIPMENT
VIEWS
BLOCK DIAGRAM
PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
CLICK ON THE ARROW
ICONS IN THE MIDDLE OF
THE SCREEN TO EXPAND
THE LEFT OR RIGHT DATAFIELD. CLICKING ON THE
BLOCK WILL RETURN THE
ORIGINAL SPLIT SCREEN.
7/18/2019 PNMT V4 Modified.ppt
8/41
NECITR-YTC
ART-SEP/03 V02
PNMT 8
PNMT MAIN SCREEN
COMMON MENU BAR
COMMON TOOL BAR
NE SPECIFIC DATA :
NE SPECIFIC MENU ITEMS:
EQUIPMENT CONFIGURATION
LINK PERFORMANCE MONITOR
EVENT LOG
MAINTENANCE
NE BLOCK DIAGRAM:
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK
DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE
DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,
LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP).
THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE
WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN
BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS
WINDOW
LINK SUMMARY WINDOW
COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS
COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEMHAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.
NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE
WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. DATA DISPLAYED DEPENDS
ON THE EQUIPMENT TYPE (PASOLINK +, V3, V4, ETC.)
EQUIPMENT SETUP
TAB SELECTION
DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P
AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.
7/18/2019 PNMT V4 Modified.ppt
9/41
NECITR-YTC
ART-SEP/03 V02
PNMT 9
PNMT WINDOW MENU ITEMS
SYSTEM HELP
LOGIN / LOGOUT
CHANGE PASSWORD
ALARM BUZZER
CONNECT
EXIT
DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT
THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE
USER NAME AND PASSWORD.
THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW
THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND
DEFINE THE BUZZER SOUND
THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN
THE NETWORK
THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM
HELP
ABOUT DISPLAY THE PNMT VERSION NUMBER
REFRESH
THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY
AND TO UPDATE EQUIPMENT INFORMATION
7/18/2019 PNMT V4 Modified.ppt
10/41
NECITR-YTC
ART-SEP/03 V02
PNMT 10
NE SPECIFIC MENU ITEMS
CONFIGURATION EVENT LOG
EQUIPMENT SETUP
MAINTENANCE
MAINT MODE ON/OFF
TX MUTE ON/OFF
CW ON/OFF
THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND
DISPLAY THE INFORMATION IN EVENT LOG WINDOW
THIS FUNCTION OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.
LINK PERFORMANCE MONITOR
BER AIS ON/OFF
SWITCHOVER (1+1)
FREQUENCY SETTING
TX POWER CONT
LAN SETTING
FRAME ID
BER THRESHOLD
AIS SEND ON/OFF
AIS RCVD ON/OFF
SC4 & SC5 SETTING
NE NAME
NOTE
BIT RATE
SYSTEM CONFIG
7/18/2019 PNMT V4 Modified.ppt
11/41
NECITR-YTC
ART-SEP/03 V02
PNMT 11
PNMT LOGIN / LOGOUT & EXIT
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPENTHE LOGIN/LOGOUT WINDOW
ENTER THE USER NAME ACCORDING TO THE
PRIVILEGES AND THE PASSWORD.
CLICK OK TO LOGIN
TO PROTECT THE NETWORK AND NETWORK
MANAGEMENT SYSTEM FROM UNAUTHORIZED
ACCESS OR MODIFICATIONS, FIVE LEVELS OF
USERS ARE DEFINED WITH DIFFERENT
PRIVILEGES. THE FUNCTIONS AVAILABLE
DEPENDS ON THE USER ACCESS LEVEL, (SEE
THE TABLE NEXT PAGE)
TO LOGOUT SELECT LOGOUT IN THE
LOGIN/LOGOUT WINDOW AND CLICK OK.
TO LOGIN SELECT LOGIN IN THE
LOGIN/LOGOUT WINDOW.
7/18/2019 PNMT V4 Modified.ppt
12/41
NECITR-YTC
ART-SEP/03 V02
PNMT 12
USER NAMES & PRIVILEGESCategory Item Monitor(0) User(1) Local(2) Remote(3) Admin(4)
MENU-SYSTEM DATE TIME ALARM BUZZER DOWNLOAD PMC PROGRAM FILE CONNECT (REMOTE LOGIN)
MENU-CONFIGURATION FILE DOWNLOAD FILE/ UPLOAD FILE UPDATE
IDU WS ALARM INHIBIT (OPTION) CH (LB1) / CH(LB2) CH (ALARM INHIBIT)
MAINTENANCE MAINTENANCE MODE TX MUTE CW
BER AIS
SWITCH OVER (1+1) EQUIPMENT CONFIGURATION FREQUENCY PLAN (CH)
TX ATTENUATION BIT RATE FRAME ID BER THRESHOLD AIS RCVD ALARM ON/OFF AIS SEND ALARM ON/OFF SC4 AND SC5
PASOLINK NAME
NOTE
AUX I/O OPTO ITEM TYPE OPTO NAME RELAY NAME RELAY CONTROL
PMON PMON THRESHOLD PMON DATA RESET SAVE TO DISK
LOGGING SAVE TO DISK
PMC RESET
7/18/2019 PNMT V4 Modified.ppt
13/41
NECITR-YTC
ART-SEP/03 V02
PNMT 13
OVERALL WINDOW
CLICK THE OVERALL TAB TO DISPLAY THE OVERALL
WINDOW
OVERALL WINDOW FOR (1+1) CONFIGURATION
OVERALL WINDOW FOR (1+0) CONFIGURATION
TX ATTENUATION USED
TX AND RX FREQUENCIES USED
BIT RATE USED
MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR
CHANGE TO YELLOW.
SELECTED TX AND RX CHANNEL IN (1+1) HOT STANDBY CONFIGURATION
FRAME ID USED
OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:
ODU TYPE USED V3 OR V4
TX POWER CONTROL USED
7/18/2019 PNMT V4 Modified.ppt
14/41
NECITR-YTC
ART-SEP/03 V02
PNMT 14
ODU WINDOWCLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU
WINDOW TO VIEW THE ODU DETAILS
ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION
CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
7/18/2019 PNMT V4 Modified.ppt
15/41
NECITR-YTC
ART-SEP/03 V02
PNMT 15
ODU DETAIL
STATUS COLORS
GREEN NORMAL
RED ALARM
(1+1) CONFIGURATION SELECTED/NOT SELECTED STATUS
GREEN SELECTED
WHITE NOT SELECTED
IF INPUT IF INPUT LEVEL IN THE ODU FALLS BELOW (APPROXIMATELY) -63 dB
TX APC ODU TX SIDE SYNTHESIZER IS UNLOCKEDTX POWER TRANSMIT POWER DECREASED BY 3 TO 5 dB
TX ATTENUATION INDICATES THE ATTENUATION VALUE USED IN MTPC MODE
TX POWER INDICATES THE ODU TRANSMIT POWER AS DETECTOR VOLTAGE AND IN dBm
ALARMS
STATUS AND MONITORING
RX LEVEL ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL
RX APC ODU RX SIDE SYNTHESIZER IS UNLOCKED
ALARMS
RX LEVEL INDICATES THE ODU RX LEVEL AS THE AGC VOLTAGE AND IN dBm
STATUS AND MONITORING
ODU-IDU LINK INDICATES THE STATUS OF THE COMMUNICATION BETWEEN IDU AND ODU
ALARMS
ODU TYPE INDICATES THE TYPE OF ODU CONNECTED TO THE V4 PASOLINK
STATUS AND MONITORING
TX SIDE ALARMS AND STATUS /MONITORING
RX SIDE ALARMS AND STATUS /MONITORING
COMMON ALARMS AND STATUS /MONITORING
7/18/2019 PNMT V4 Modified.ppt
16/41
NECITR-YTC
ART-SEP/03 V02
PNMT 16
IDU WINDOW
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
IDU WINDOW FOR (1+1) CONFIGURATIONIDU WINDOW FOR (1+0) CONFIGURATION
CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
7/18/2019 PNMT V4 Modified.ppt
17/41
NECITR-YTC
ART-SEP/03 V02
PNMT 17
IDU DETAIL
(1+1) CONFIGURATION ON LINE SELECTED/NOT SELECTED STATUS
GREEN SELECTED
WHITE NOT SELECTED
MOD MODULATOR 850 MHz PLL OSCILLATOR UNLOCK ALARM
TX DPU LOSS OF TX SIDE CLOCK
TX SIDE IDU ALARMS
STATUS COLORS
GREEN NORMAL
RED ALARM
DEM RX CARRIER NOT SYNCHRONIZED OR LOST
LOW BER WHEN THE RECEIVE BER IS > 10-6
HIGH BER WHEN THE RECEIVE BER IS >10-3
RX SIDE IDU ALARMS
BER ALARM ALARM TRIGGER POINT SELECTABLE (10-3,10-4,10-5 AND 10-6)
FRAME ASYNC LOSS OF RX FRAME SYNCHRONIZATION AT THE RX DPU
ODU-IDU LINK STATUS OF THE ODU-IDU IF LINK
IDU COMMON ALARMS
CPU STATUS OF THE IDU CPU
INPUT LOSS OF WS INPUT SIGNAL IN THE WS INTFC CARD
WAY SIDE( OPTION) ALARMS
BP OUTPUT RX WS SIGNAL LOSS FROM DEMODULATOR (WS INTFC CARD)AIS SEND STATUS AIS SENT OUT FORM THE WS INTFC CARD
AIS RECEIVED AIS DETECTED IN WS INPUT SIGNAL
ALARM INHIBIT WHEN WS SIGNAL IS NOT USED ALARM INHIBIT STATUS
PINK MINOR ALARM
RX CLK LOSS LOSS OF RX SIDE CLOCK
LAN INTFC LAN INTERFACE OPTION CARD IS NORMAL OR FAULTY
LAN INTFC (OPTION) ALARMS
LAN LINK LAN PORT 1 & 2 LINK STATUS NORMAL OR ALARMNormal
Normal
Normal
Normal
Normal
Port 1 Port 2
LAN COLLISION COLLISION STATUS OF THE LAN PORT 1 & 2
7/18/2019 PNMT V4 Modified.ppt
18/41
NECITR-YTC
ART-SEP/03 V02
PNMT 18
IDU DETAIL
INPUT LOSS OF 2MB INPUT SIGNAL
2MB CH STATUS AND ALARMS
BP OUTPUT RX 2MB SIGNAL LOSS DETECTED FROM DEMODULATOR
AIS SEND AIS SENT OUT STATUS FORM THE 2MB INTFC CARD
AIS RECEIVED
AIS DETECTED STATUS IN 2MB INPUT SIGNALLB-1 UNDER MAINTENANCE MODE NEAR END LOOPBACK STATUS
NORMAL/SEND
NORMAL/RECEIVED
ON/OFF
NORMAL/ALARMNORMAL/ALARM/INHIBIT
ON/OFF
ON/OFF
LB-2 UNDER MAINTENANCE MODE, TO FAR END LOOPBACK STATUS
ALARM INHIBIT ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS
CLICK THE CH BUTTON TO OPEN THE CHANNEL
CONTROL WINDOW
STATUS COLORS
GREEN NORMAL
RED ALARM
YELLOW MAINTENANCE
LOOPBACK 2 CONTROLLOOPBACK 1 CONTROL
CH ALARM INHIBIT CONTROL
BP OUTPUT RX 2MB SIGNAL LOSSDETECTED FROM DEMODULATOR
ALARM INHIBITOFFWS
WS CH STATUS AND ALARMS
INPUT LOSS OF 2MB WS INPUT SIGNAL
BP OUTPUT RX 2MB WS SIGNAL LOSS DETECTED FROM DEMODULATOR
AIS SEND AIS SENT OUT STATUS FORM THE WS INTFC CARD
AIS RECEIVED AIS DETECTED STATUS IN WS INPUT SIGNAL
ALARM INHIBIT ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS
7/18/2019 PNMT V4 Modified.ppt
19/41
NECITR-YTC
ART-SEP/03 V02
PNMT 19
CHANNEL CONTROL
LB1 TAB PROVIDES NEAR END LOOPBACK.SELECT ON OR OFF AND CLICK ON
EXECUTE TO ENABLE NEAR END
LOOPBACK ON THE SELECTED CHANNEL.
BEFORE ENABLING LOOPBACK SELECT
MAINTENANCE MODE ON. OTHERWISE AN
ERROR MESSAGE. IS DISPLAYED
IN THE IDU WINDOW CLICK ON
THE CH # TO BE CONTROLLED.
SELECTED CHANNEL CONTROLWINDOW OPENS
LB2 TAB PROVIDES FAR END
LOOPBACK. SELECT ON OR OFF AND
CLICK ON EXECUTE TO ENABLE FAR
END LOOPBACK ON THE SELECTED
CHANNEL..
ALARM TAB PROVIDES INHIBIT OF ALARM
ON THE SELECTED CHANNEL. USED TO
INHIBIT ALARMS FROM THE UNUSED 2 MB
CHANNELS.
ON INHIBIT ALARMS
OFF - ENABLE ALARMS
CLICK EXECUTE TO SELECT THE CHANGE
INDICATE LOOPBACK ON, YELLOW BACKGROUNDINDICATE MAINTENANCE MODE
INDICATE CHANNEL ALARMS INHIBIT ON
INDICATE CHANNEL ALARMS INHIBIT ON
7/18/2019 PNMT V4 Modified.ppt
20/41
NECITR-YTC
ART-SEP/03 V02
PNMT 20
CHANGE PASSWORD
ENTER THE NEW PASSWORD
CLICK OK TO CHANGE THE
PASSWORD.
CLICK ON CHANGE PASSWORD IN THE SYSTEM
DROPDOWN MENU TO OPEN THE CHANGE PASS WORD
WINDOW.
ENTER THE OLD PASSWORD
RE-ENTER THE NEW PASSWORD TO CONFIRM
CLICK CANCEL TO EXIT WITHOUT
CHANGING PASSWORD
7/18/2019 PNMT V4 Modified.ppt
21/41
NECITR-YTC
ART-SEP/03 V02
PNMT 21
ALARM BUZZERCLICK ON ALARM BUZZER ON
THE SYSTEM DROP DOWN
MENU TO OPEN THE ALARMBUZZER SETTING WINDOW.
SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER
SOUND CAN BE CHANGED BY SELECTING A DIFFERENT
WAV FILE. USE BROWSE TO LOCATE THE PATH TOTHE WAV FILE.
SELECT NO SOUND TO DISABLE THE BUZZER
CLICK HERE TO TEST THE BUZZER SOUND
BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES
AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL
FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED
BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.
SELECT BEEP TO ENABLE THE
BUZZER WITH BEEP FREQUENCIES
INSTEAD OF WAVE FILE SOUND
CLICK OK TO IMPLEMENT THE
OPTION SELECTED OR CLICK
CANCEL TO EXIT WITHOUTCHANGING THE SETTINGS.
7/18/2019 PNMT V4 Modified.ppt
22/41
NECITR-YTC
ART-SEP/03 V02
PNMT 22
SEARCH / CONNECT TO NETWORK ELEMENT
CLICK THE SEARCH FOR NETWORK ELEMENT TO
SEARCH AND LIST THE OTHER NEs IN THE
NETWORK
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.
TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT ANDHIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK
ELEMENT FROM THE LIST DROP DOWN MENU. SELECTYES FROM THE
DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE
DISPLAYED IN THE LINK SUMMARY WINDOW.
SEARCH FOR NETWORK ELEMENT
CONNECT TO NETWORK ELEMENT
TOOL BAR ITEMS
LIST MENU
7/18/2019 PNMT V4 Modified.ppt
23/41
NECITR-YTC
ART-SEP/03 V02
PNMT 23
HELP FUNCTION
OPEN THE LOGIN/LOGOUT WINDOW
CONNECT - OPEN THE NE LIST WINDOW
BUZZER STOP ICON IS ACTIVE ONLY WHENTHE, THE ALARMED EQUIPMENT DISPLAY
WINDOW IS SELECTED FROM THE TABs OR
FROM THE BLOCK DIAGRAM SYMBOLS.DISPLAY THE PNMT SOFTWARE VERSION INFORMATION
PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN
PDF FILE FORMAT. IF THE ACROBAT READER ISINSTALLED IN THE PNMT PC, CLICKING HELP AND
SELECTING THE RELEVANT PNMT FILE WILL OPEN THE
PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.
REFRESH REFRESH METERING ITEMS
7/18/2019 PNMT V4 Modified.ppt
24/41
NECITR-YTC
ART-SEP/03 V02
PNMT 24
EQUIPMENT CONFIGURATION WINDOW
SHOW THE TYPE AND NUMBEROF OPTIONAL INTERFACE
CARDS MOUNTED
INDICATES THE ODU
FREQUENCY BAND
INFORMATION AND TX/RX
FREQUENCIES
SHOW THE LAN SIGNAL
STATUS FOR PORT1 AND
PORT2, WHEN MAIN LANINTFC OPTION IS USED
SHOW THE CURRENT IDU
CONFIGURATION
INDICATES THE TXPOWER CONTROL MODE
AND TX ATT
SHOW THE
SERVICE CHANNEL
INFORMATION
SHOW IP ADDRESS AND NAME OF
THE SELECTED NE
SHOW THE WS
CHANNELINFORMATION
7/18/2019 PNMT V4 Modified.ppt
25/41
NECITR-YTC
ART-SEP/03 V02
PNMT 25
FREQUENCY AND POWER SETTING
CLICK ON THE FREQUENCY PLAN BUTTON TO SELECT
THE ODU TX AND RX FREQUENCIES.
CLICK THE EXECUTE BUTTON TO CHANGE THE FREQUENCIES.
THIS OPERATION WILL INTERRUPT THE TRAFFIC
REFER TO THE RADIO FREQUENCY ASSIGNMENT TABLES TO
SELECT THE CHANNEL NUMBER CORRESPONDING TO THE
REQUIRED TRANSMIT AND RECEIVE FREQUENCIES.
SELECT THE CHANNEL NUMBER AND THE CORRESPONDING TX
AND RX FREQUENCIES FOR THE SELECTED CHANNEL. ARE
DISPLAYED
CLICK THE CLOSE BUTTON TO EXIT THE FREQUENCY PLAN
WINDOW.
CLICK ON THE TX ATTENUATION
BUTTON TO SET THE TX ATTENUATION
FOR MTPC.
SELECT THE AMOUNT OF ATTENUATION
REQUIRED AND CLICK THE EXECUTE BUTTON.
THE TX ATTENUATION RANGE OF ODU IS 0 TO
30 dB
CLICK CLOSE TO EXIT THE TX ATTENUATION
SETTING WINDOW.
INFORMATION ABOUT THE ODU FREQUENCY BAND ARE
DISPLAYED
ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE
CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING.
IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs.
This information may include :
TX frequency used is High band or Low band
Frequency Sub band used A, B, C, or D.
Default Channel and TX frequency set in the ODU.
CH Separation
shift frequency
7/18/2019 PNMT V4 Modified.ppt
26/41
7/18/2019 PNMT V4 Modified.ppt
27/41
NECITR-YTC
ART-SEP/03 V02
PNMT 27
IDU SETTINGIDU SECTION OF THE EQUIPMENT SETUP WINDOW FOR
THE SELECTED PASOLINK HAS CONTROL SETTINGS FOR
THE MAIN SIGNAL.
CLICK BIT RATE BUTTON TO OPEN THE BIT RATE SETTING
WINDOW. THIS FUNCTION APPLIES TO THE VARIABLE BIT RATE
IDUs. SELECT THE BIT RATE AND CLICK THE EXECUTE BUTTON
TO CHANGE THE BIT RATE SETTING..
CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY
CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED
CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE
REDUNDANCY CONFIGURATION.
MAKE SURE THAT BOTH NEs IN THE
HOP HAVE THE SAME FRAME ID VALUE.
CLICK BER THRESHOLD BUTTON TO OPEN THE BER
THRESHOLD SETTING WINDOW. SELECT THE DESIRED
VALUE FOR THE BER THRESHOLD. CLICK ON THE
EXECUTE BUTTON TO SET THE BER THRESHOLD VALUE.
BIT RATE SETTING
REDUNDANCY BER THRESHOLD SETTING
AT THIS BER THRESHOLD VALUE AIS SIGNAL IS INSERTED
TO THE 2MB STREAMS
FRAME ID
CLICK FRAME ID BUTTON TO OPEN THE
FRAME ID SETTING WINDOW.
SELECT THE FRAME ID AND CLICK ON
THE EXECUTE BUTTON TO SET IT.
7/18/2019 PNMT V4 Modified.ppt
28/41
NECITR-YTC
ART-SEP/03 V02
PNMT 28
AIS SEND / RCVD SETTINGIN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION
CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE
DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT.
SELECT AIS RECEIVED CONDITION AS AN
ALARM CONDITION OR STATUS
CONDITION.
CLICK EXECUTE TO CARRY OUT THE
SETTING.
CLICK CLOSE TO EXIT
SELECT AIS SEND CONDITION AS AN
ALARM CONDITION OR STATUS
CONDITION.
CLICK EXECUTE TO CARRY OUT THE
SETTING.
CLICK CLOSE TO EXIT
CLICK AIS RCVD BUTTON TO OPEN THE
AIS RCVD SETTING WINDOW.CLICK AIS SEND BUTTON TO OPEN THEAIS SEND SETTING WINDOW.
7/18/2019 PNMT V4 Modified.ppt
29/41
NECITR-YTC
ART-SEP/03 V02
PNMT 29
SERVICE CHANNEL SETTING
OVERHEAD SERVICE CHANNELS
SC1 EOW Analog
SC2 DSC3 Analog ASC INTFC or
DSC INTFCOption
SC3 DSC4 Digital Option
SC4 DSC1 Digital 9.6Kbps RS 232C or
64Kbps with G703/V11 card Option
SC5 DSC2 Digital 9.6Kbps RS232C / RS422 / RS485
SC6 NMS
64K V.11 64K G703 9.6K RS-232
SC4
SC4
SC4 AS A DEFAULT USE A 9.6K RS232 INTERFACE. IF THE
OPTIONAL 64K INTERFACE CARDS ARE MOUNTED. THEN THE
SC4 BUTTON IS ACTIVE TO SELECT EITHER 9.6 OR 64K.
INTERFACE
SERVICE CHANNELS USED IN THE PASOLINK IS SHOWN ON
THE TABLE. SC2 AND 3 NEEDS OPTIONAL ANALOG OR
DIGITAL SERVICE CHANNEL INTERFACE CARD.
WHEN OPTIONAL 64K INTERFACE IS MOUNTED THIS BUTTON
IS ACTIVE.. CLICK ON SC4 BUTTON TO OPEN THE SC4
SETTING WINDOW.
SELECT THE REQUIRED OPTION AND CLICK EXECUTE.
CLICK ON SC5 BUTTON TO OPEN THE SC5 SETTING WINDOW.
CLICK CLOSE TO EXIT THE WINDOW
OPTION PANEL STATUS SHOWS THE OPTION CARDSMOUNTED IN THE IDU.
7/18/2019 PNMT V4 Modified.ppt
30/41
NECITR-YTC
ART-SEP/03 V02
PNMT 30
PMC CARD SETTINGTHE NAME ENTERED TO IDENTIFY THE NETWORK
ELEMENT CAN BE CHANGED FORM THIS WINDOW. A
MAXIMUM OF 32 CHARACTERS CAN BE USED.
A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE
ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS
CAN BE USED IN THIS FIELD
FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE
NAME BUTTON TO OPEN THE NE NAME SETTING
WINDOW.
CLICK THE NOTE BUTTON TO OPEN THE
NOTE WINDOW.
ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE
NOTE IN THE EQUIPMENT SETUP WINDOW.
ENTER THE NAME AND CLICK EXECUTE TO SHOW THENAME IN THE EQUIPMENT SETUP WINDOW.
7/18/2019 PNMT V4 Modified.ppt
31/41
NECITR-YTC
ART-SEP/03 V02
PNMT 31
MAINTENANCECLICK MAINTENANCE, ON THE,
CONFIGURATION DROP DOWN
MENU TO OPEN THE
MAINTENANCE WINDOW
TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO
MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE
WINDOW TO OPEN MAINTENANCE MODE SELECTION WINDOW. SELECT
MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE
SELECTION
THIS CONTROL MUTE THE OUTPUT
POWER OF THE SELECTED PASOLINKCHANNEL .
CLICK THE TX MUTE BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THETX MUTE CONTROL WINDOW. CLICK
ON/OFF AND EXECUTE TO IMPLEMENT
THE CONTROL.
THIS CONTROL TRANSMIT AN UN-
MODULATED CARRIER FOR
MEASUREMENT PURPOSE.
CLICK THE CW BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THE
CW CONTROL WINDOW. CLICK ON/OFF
AND EXECUTE TO IMPLEMENT THE
CONTROL.
THIS CONTROL INHIBIT INSERTION OFAIS DURING BER ALARM CONDITION
FOR MEASUREMENT PURPOSE.
CLICK THE BER AIS BUTTON ON THEMAINTENANCE WINDOW TO OPEN THE
BER AIS CONTROL WINDOW. CLICK
ON/OFF AND EXECUTE TO IMPLEMENT
THE CONTROL.
THESE CONTROL AREAVAILABLE FOR (1+1)
CONFIGURATION.
PROVIDES MANUAL
SWITCH OVER OF
PASOLINK CHANNEL
FOR NORMAL OPERATION
SELECT AUTO FOR AUTO
REDUNDANCYSWITCHING..
TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO
NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST.
7/18/2019 PNMT V4 Modified.ppt
32/41
7/18/2019 PNMT V4 Modified.ppt
33/41
NECITR-YTC
ART-SEP/03 V02
PNMT 33
PMC & VERSION WINDOWSCLICK THE PMC SYMBOL ON THE BLOCK DIAGRAM OR
THE PMC TAB TO DISPLAY THE PMC WINDOW FOR THE
SELECTED NE.
VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE ,SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER
ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED
NETWORK ELEMENT.
CONFIGURATION AND SETTING OF THE PASOLINK
MANAGEMENT CARD IS PROVIDED IN THIS WINDOW.
CLICK THE VERSION TAB TO DISPLAY THE VERSION
INFORMATION WINDOW FOR THE SELECTED NE.
7/18/2019 PNMT V4 Modified.ppt
34/41
NECITR-YTC
ART-SEP/03 V02
PNMT 34
DATE TIME SETTINGDATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
CLICK DATE/TIME
BUTTON IN THE PMC
WINDOW TO OPEN THE
DATE/TIME SETTING
CONTROL WINDOW
TO DISPLAY THE CURRENT DATE/TIME
STORED IN THE PM CARD, SELECTGET DATE/TIME AND CLICK EXECUTE.
THE CURRENT DATE/TIME STORED IN
THE PM CARD, IS DISPLAYED.
TO DISPLAY AND SET THE DATE/TIME SET IN THEPNMT PC TO THE PM CARD, SELECT DISPLAY PC
TIME BOX AND CLICK THE EXECUTE BUTTON.
CHANGE THE DATE /TIME SETTING AS REQUIRED,
CLICK THE EXECUTE BUTTON.
TO CHANGE THE PM CARD DATE TIME SETTING,
SELECT SET DATE/TIME.
TO CHANGE THE PM CARD DATE TIME SETTING,
SELECT SET DATE/TIME.
[PMC WINDOW]
7/18/2019 PNMT V4 Modified.ppt
35/41
NECITR-YTC
ART-SEP/03 V02
PNMT 35
DOWN LOAD CONFIGURATION FILESTHIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE
NETWORK CONFIG TOOL TO THE PM CARD IN THE SELECTED NETWORK ELEMENT.
THERE ARE TWO FILES CREATED FOR EACH NE, SYSTEM.CFG CONTAINS THE IP
ADDRESS OF THE PM CARD AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION.
THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK
NETWORK WHERE THE PM CARD IS LOCATED.
CLICK THE CONFIGURATION FILE BUTTON UNDER THE
DOWNLOAD (PC>>PMC) IN THE PMC WINDOW, TO OPEN THE
DOWNLOAD CONFIGURATION FILE WINDOW.
SELECT EACH CONFIG FILE ONE BY ONE FROM
THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO
THE FILE SELECTED IN THE TYPE WINDOW.
CLICK EXECUTE BUTTON TO DOWN LOAD THE
SELECTED CONFIG FILE..
MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWNLOADED TO THE PM CARD IN THE CORRECT NE. INCORRECT
CONFIGURATION FILE WILL LEAD TO PM CARD OR NETWORK
FAILURE
WARNING
REPEAT THE DOWNLOAD PROCEDURE FOR THE
OTHER CONFIG FILE..
A MESSAGE WINDOW INDICATE THE STATUS OF
THE DOWNLOAD OPERATION AND IT WILL CLOSEAUTOMATICALLY ONCE THE OPERATION IS OVER
AFTER THE SUCCESSFUL DOWN LOAD OFTHE CONFIGURATION FILES. CLICK
UPDATE BUTTON. UPDATE
CONFIGURATION FILE WINDOW OPENS.
SELECT THE APPROPRIATE BOX FOR THETYPE OF CONFIGURATION FILE(S) THAT
WILL BE UPDATED.
System Config
Network ConfigME Config
With ROM (PMC Program ) Switching
PPP Config
Execute
CLICK OK BUTTON TO START THE UPDATE
OPERATION..
WHEN UPDATING SYSTEM.CFG FILE , PMC TO
PMC COMMUNICATION WILL BE LOST WHEN PM
CARD INITIALIZES TO THE NEW SYSTEM
CONFIGURATION. DURING THIS TIME PNMTCONNECTION TO THE PASOLINK WILL BE LOST
BUT WILL AUTOMATICALLY BE RECONNECTED
AFTER THE PMC RESETS
MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED
THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE
THE PM CARD WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE
PM CARD FAILURE.
CLICK CLOSE BUTTON WHEN DONE
UPDATE
DOWN LOAD
[PMC WINDOW]
7/18/2019 PNMT V4 Modified.ppt
36/41
NECITR-YTC
ART-SEP/03 V02
PNMT 36
DOWN LOAD PROGRAM FILE
A:\pm.pof
THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE PM
CARD. THIS OPERATION AFFECTS THE ONLY THE PMC TO PMC COMMUNICATION.
AND WILL NOT DISRUPT THE RADIO LINK.
CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE
PMC WINDOW.
ENTER THE PATH TO THE
PROGRAM FILE TO BEDOWNLOADED OR CLICK BROWSE
TO LOCATE THE PROGRAM FILE.
CLICK THE EXECUTE BUTTON TO
START DOWNLOAD OPERATION
A MESSAGE WINDOW APPEARS
TO SHOW THE STATUS OF THE
DOWNLOAD OPERATION, AND
WILL CLOSE AUTOMATICALLYONCE THE DOWNLOAD IS
COMPLETED.
MAKE SURE THAT THE CORRECTPROGRAM FILE IS DOWNLOADED
TO THE PM CARD. INCORRECT
PROGRAM FILE WILL LEAD TO PM
CARD FAILURE.
WARNING
CLICK ON THE PMC RESET
BUTTON TO SWITCH TO THE NEW
PROGRAM FILE
SELECT WITH ROM (PMC PROGRAM)
SWITCHING OPTION IF YOU WANT TO SWITCH
TO A NEWLY DOWNLOADED PMC PROGRAMFILE RESETTING THE PMC WILL NOT A FFECT THE
TRAFFIC. THE CONNECTION TO THE
SELECTED PASOLINK WILL B E LOST FOR FEW
MINUTES AND WILL B E RECONNECTED
AUTOMATICALLY.
PM CARD CAN BE RESET
USING THIS FUNCTION
CLICK THE PMC RESET
BUTTON ON THE PMC
WINDOW.
CLICK EXECUTE BUTTON TO RESET THE PM
CARD.
[PMC WINDOW]
7/18/2019 PNMT V4 Modified.ppt
37/41
NECITR-YTC
ART-SEP/03 V02
PNMT 37
UPLOAD CONFIGURATION FILE
SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE
WINDOW., SYSTEM CONFIG OR NETWORK CONFIG.
THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM
THE PM CARD OF THE SELECTED NE TO THE PNMT PC.
ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE
WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION,
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..
AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE
THE WINDOW.
CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (PM>>PC) TO OPEN
THE UPLOAD CONFIGURATION FILE WINDOW.
[PMC WINDOW]
7/18/2019 PNMT V4 Modified.ppt
38/41
NECITR-YTC
ART-SEP/03 V02
PNMT 38
EVENT LOG
CLICK ON THE EVEN LOG IN
THE NE SPECIFIC MENU BAR
TO UPLOAD THE EVEN LOG
ITEMS FROM THE SELECTED
NE.
A MESSAGE WINDOW
SHOWS THE PROGRESS OFTHE UPLOAD
EVENT LOG VIEW WINDOW SHOWS
ALARM EVENTS, COMMAND EVENTS
AND STATUS CHANGES.
DIFFERENT COLORS SHOWS THE
TYPE OF EVENT.
EVENT LOG IS PRESENTED IN A TABLE
FORM SHOWING THE DATE OF THE
EVENT , THE ITEM THAT TRIGGERED
THE EVENT AND THE STATUSCHANGE.
CLICK FILE-UPLOAD TO REFRESH THE EVENT
LOG DISPLAY
CLICK FILE-SAVE AS TO SAVE THE EVENT
LOG TO
CLICK FILE-PRINT TO PRINT THE EVENT
LOG INFORMATION
NE SPECIFIC MENU BAR
7/18/2019 PNMT V4 Modified.ppt
39/41
NECITR-YTC
ART-SEP/03 V02
PNMT 39
LINK PERFORMANCE MONITOR
THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED
ACCORDING TO THE G.826 RECOMMENDATIONS.
NE SPECIFIC MENU BAR
SES SEVERELY ERROR SECONDS
UAS UNAVAILABLE SECONDS
BBE BACKGROUND BLOCK ERRORS
THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW
INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS
EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUESCAN BE SET IN THRESHOLD WINDOW. ALL DATA CAN BE RESET BY
USING ALL DATA RESET BUTTON. ( MAKE SURE THAT THE
CURRENT DATA HAS BEEN SAVED AS THIS OPERATION WILL
DELETE AL L THE PERFORMANCE DATA IN THE CURRENT WEEK.)
CLICK ON THE LINK PERFORMANCE MONITOR IN THE NESPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF
THE PASOLINK TO BE MONITORED.ES ERROR SECONDS
SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE
TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN
THE ALARM RECOVER IN THE APPROPRIATE FIELD.
AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TOACTIVATE THE NEW SETTING.
CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..
THRESHOLD VALUE SETTING
CLICK THE THRESHOLD(%) BUTTON TO OPEN THE THRESHOLD SETTING
WINDOW.
CURRENT BER VALUE IS SHOWN IN THIS FIELD
7/18/2019 PNMT V4 Modified.ppt
40/41
NECITR-YTC
ART-SEP/03 V02
PNMT 40
LINK PERFORMANCE MONITOR
THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THEDETAILED 15MIN PERFORMANCE DATA
CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE
MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL
WINDOW.
THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF
THE LAST .8 DAYS.
THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE
TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY
DATA FOR THAT SPECIFIC DATE..
CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA
WINDOW FOR THE SELECTED DATE
CLICK FILE SAVE AS TO SAVE THE DATA IN TEXT FORMAT
CLICK FILE - UPLOAD TO REFRESH THE DATA
7/18/2019 PNMT V4 Modified.ppt
41/41
NECITR-YTC
ART-SEP/03 V02
NEC International Training, Ltd.Yokohama Training Center
PASOLINK V4 SOFTWARE