pour exemple : xxxxxxxxxxxxxxx
pour exemple : xxxxxxxxxxxxxxx
232
Plexo boxesplexo boxes and adapter IP55
DLP trunking plate
IP55 box and adaptor with membraneAllows operation of switches without opening coverGrey colour box made from ABSAdaptor material polycarbonate, membrane material PVC
Pack Cat.Nos IP 55 box Plexo 55
Adaptor for flush mounting
20 6806 33 Adaptor for flush mounting - 100 x 122 x 283 module
10 6806 11 Box with adapter - 1 module 76 x 76 x 65
10 6806 12 Box with adapter - 2 module 76 x 76 x 65
10 6806 13 Box with adapter - 3 module 76 x 100 x 65
5 6806 14 Box with adapter - 4 module 76 x 132 x 65
5 6806 19 Box with adapter IP55 - 132 x 132 x 658 module verticle (4+4 modules)
6806 13
6806 336806 19
6806 12
Dimensions (mm)H x W x D
Pack Cat.Nos Supports for mounting wiring accessories
ArteorTM supports
Clip-on supports which can be fitted side by side Supplied with finishing plate
5/50 0109 10 1 modules - for 40 mm cover
20 0109 21 2 modules - for 65 mm cover 0109 22 2 modules - for 85 mm cover
50/50 0109 31 3 modules - for 65 mm cover 0109 32 3 modules - for 85 mm cover
10 0109 41 4 modules - for 65 mm cover 0109 42 4 modules - for 85 mm cover
5 0109 61 6 modules - for 65 mm cover 0109 62 6 modules - for 85 mm cover
5 0109 81 8 modules - for 65 mm cover 0109 82 8 modules - for 85 mm cover
10/100 0109 27 Insulation unit for 2 modules (ArteorTM) can be fitted together to create 4/6/8 module supports
5/50 0109 37 Insulation unit for 3 modules (ArteorTM) supports
Bold catalogue numbers are products normally available with Legrand (India) stockists.Cat. nos. that are not bold - delivery within 4 - 8 weeks from the date of order.
Bold packing quantity is our mandatory packing. Orders to be placed by Legrand (India) stockists in multiples of the same.
0109 41
0109 42
0109 21
351
pour exemple : xxxxxxxxxxxxxxx
pour exemple : xxxxxxxxxxxxxxx
MosaicTM boxesplexo boxes and adapter IP55
Pack Cat. nos. IP 55 box Plexo 55
IP55 box and adaptor with membrane Allows operation of switches without opening cover Grey colour box made from ABS Adaptor material polycarbonate, membrane material
PVC Adaptor for flush mounting
1/20 6806 33 Adaptor for flush mounting - 100 x 122 x 283 module
1/10 6806 11 Box with adapter - 1 module 76 x 76 x 65 1/10 6806 12 Box with adapter - 2 module 76 x 76 x 65 1/10 6806 13 Box with adapter - 3 module 76 x 100 x 65 1/5 6806 14 Box with adapter - 4 module 76 x 132 x 65 1/5 6806 19 Box with adapter IP55 - 132 x 132 x 65
8 module verticle (4+4 modules)
6806 13
6806 336806 19
6806 12
Dimensions (mm)H x W x D
Pack Cat. nos. IP 55 modular Plexo 55
Can accept 2 Mosaic modules Suitable for hotel kitchens, food stores, laboratories, clean rooms.
Adaptor
10/100 0695 80 Grey/white with smoked cover. Fits on box cat. no. 0696 51, 0696 72, 0696 80 IP 55 - IK 07 boxes - grey
10/100 0696 51 Can receive Plexo 55 adaptors with Mosaic using special cable gland which can be cut as per requirement.
5/50 0696 72 2 gang horizontal 2 entries
5/25 0696 80 3 gang horizontal 3 entries
IP 55 - IK 07 boxes - white
10/100 0696 89 Can receive Plexo 55 adaptors with Mosaic using special cable gland which can be cut as per requirement.
Mosaic adaptor with box for IP 66
1 6846 38 3 modules with transparent lid
MosaicTM boxesplexo 55
Bold catalogue numbers are products normally available with Legrand (India) stockists. Cat. nos. that are not bold - delivery within 4 - 8 weeks from the date of order.
Bold packing quantity is our mandatory packing. Orders to be placed by Legrand (India) stockists in multiples of the same.
0696 51
0696 726846 38
0695 80
for example xxxxxxxxxxxxxxx
Bold catalogue numbers are products normally available with Legrand (India) stockists. Cat.Nos that are not bold - delivery within 4 - 8 weeks from the date of order.
Bold packing quantity is our mandatory packing. Orders to be placed by Legrand (India) stockists in multiples of the same.
floor boxesselection chart
Solution for Type of Floor box Lid and Trim
Screed floor
ox 0896 44
Floor box for carpet 6896 31
Floor box for tile / marble
Lid and Trim - SS304; 2 cable outlet 6896 52
Lid and Trim - Headband and single cable outlet - Painted Grey RAL 7031
6896 55
Lid and Trim - Headband and single cable outlet - Stainless Steel GI
6896 56
Hea ox
Floor box without cable exit - IP 66 - 8 KN Load
0896 83 + 0896 85
Floor box without cable exit - IP 66 - 20 KN Load
0896 84 + 0896 85
Floor box with cable exit - IP 14 - 8 KN Load
0896 87
+
0896 86
+
0896 83
Floor box with cable exit - IP 14 - 20 KN Load
0896 87 +
0896 86
+
0896 84
Raised floor
ox 0896 44 -
Floor box for carpet 6896 31 -
Access box 0893 07 -
+
+
+
+
+
+
for example xxxxxxxxxxxxxxx
Bold catalogue numbers are products normally available with Legrand (India) stockists. Cat.Nos that are not bold - delivery within 4 - 8 weeks from the date of order.
Bold packing quantity is our mandatory packing. Orders to be placed by Legrand (India) stockists in multiples of the same.
Back box Support plates for power Waved support plate for data Plates for data
0896 49 - - -
6896 34 6896 17 6896 78 6896 62
0896 04 6896 17 6896 78 6896 62
0896 04 6896 17 6896 78 6896 62
0896 04 6896 17 6896 78 6896 62
0896 34 - - -
0896 34 - - -
0896 34 - - -
0896 34
- - - -
6896 38 6896 17 6896 78 6896 62
- - - -
A RacewaysB CouplerC Junction boxD Fixing bracketE Vertical trunking such as DLP
F RiserG Floor box (back-box + lid and
trim) Socket outlets and data socket plates to be ordered separately
System overview
ABD C
G E
F
Backbox Cat.Nos 6896 34 and 0896 04The backbox should be fixed directly on the slab. The backbox has to be equipped with wiring accessory plates and lid & trim. The backbox allows deviation of power and data cable: Adjustable height from 65 to 90mm. Side plates are pierced to suit raceways and are supplied with knockouts to fit conduits (20 or 25mm diameter). Backboxes consist of a base, levelling system and a disposable cover protection
Disposable cover protection
Levelling system
Base
Z
Y X
Dimensions Backbox (mm):
Cat.Nos X Y Z 6896 34 / 0896 04 325 325 90
Cat.Nos W V U6896 34/0896 04 276 264 264
Metal frame (mm):
U
W
V
floor boxes for carpetscreed floor
Installation principleBackboxes are to be used with lid & trim Once the screed is dry, remove disposable cover protection
Lock the frame onto the backbox by pushing down clips onto the threaded rods in each corner.
Connect wiring to accessory plates and them fix to the backbox. Finally, earth the system.
Fit carpet and clip the lid and trim onto the backbox (push and fit principle)
To install the backbox:Lift the frame (A) and retainers will automatically drop out (B).
8 mm15 mm
max.
Bac kboxA B