+ All Categories
Home > Documents > precision PVT viscometer - TECNOVA...

precision PVT viscometer - TECNOVA...

Date post: 01-Nov-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
1
As it is Hydramotion’s policy constantly to develop and improve its products, some information contained in this document may change without notice M04-01-051 Rev2 06/16 continuous PVT tracing one sweep measurement — wide viscosity range high accuracy and repeatability no moving parts — no maintenance SPECIFICATION HyperVisc 100 precision PVT viscometer 0 - 10,000+ cP in one single range 1 second 1% of reading or ±0.1 cP 0.3% of reading or ±0.05 cP –50 - +250 °C, +300 °C or +350 °C * integral thermometer 690, 1380 or 2070 bar (10,000, 20,000 or 30,000 psi) * 4 ml * HiP HF4 * all-welded, crevice-free sensor: alloy C276 (EN 2.4819) measurement cell: alloy C22 (EN 2.4602) or alloy C276 (EN 2.4819) * N6 0.8 μm Ra optional: electropolished, electroplated * type: V-Con 100 ingress protection: IP65 materials: SS316 (EN 1.4401) + aluminium alloy 6082 (EN AW-6082) ViscoLink data viewing and logging package (Windows-based for PC) Viscosity range Measurement time Accuracy Repeatability Temperature range Measured temperature Pressure rating Sample volume Process connection Construction Materials Surface finish Interface Software * Custom variations to specification available to order HV1 transducer in measurement cell 41mm 150mm 100mm 210mm
Transcript
Page 1: precision PVT viscometer - TECNOVA HTtecnovaht.it/wp-content/uploads/2016/10/M04-01-051-Rev2-HyperVis… · M04-01-051 Rev2 06/16 As it is Hydramotion’s policy constantly to develop

As it is Hydramotion’s policy constantly to develop and improve its products, some information contained in this document may change without noticeM04-01-051 Rev2 06/16

continuous PVT tracing

one sweep measurement — wide viscosity range

high accuracy and repeatability

no moving parts — no maintenance

SPECIFICATION

HyperVisc 100 precision PVT viscometer

0 - 10,000+ cP in one single range

1 second

1% of reading or ±0.1 cP

0.3% of reading or ±0.05 cP

–50 - +250 °C, +300 °C or +350 °C *

integral thermometer

690, 1380 or 2070 bar

(10,000, 20,000 or 30,000 psi) *

4 ml *

HiP HF4 *

all-welded, crevice-free

sensor: alloy C276 (EN 2.4819)

measurement cell: alloy C22 (EN 2.4602)

or alloy C276 (EN 2.4819) *

N6 0.8 µm Ra

optional: electropolished, electroplated *

type: V-Con 100

ingress protection: IP65

materials: SS316 (EN 1.4401)

+ aluminium alloy 6082 (EN AW-6082)

ViscoLink data viewing and logging

package (Windows-based for PC)

Viscosity range

Measurement time

Accuracy

Repeatability

Temperature range

Measured temperature

Pressure rating

Sample volume

Process connection

Construction

Materials

Surface finish

Interface

Software

* Custom variations to specification available to order

HV1 Interface Unit

HV750 Readout Unit HV1 Transducer 0 100mm

Heated zone

HV1 transducer in measurement cell

M20cable gland

316 stainless steel process headIP67

24mm

Flange fitting shown as example

41mm

150mm

100mm

210mm

Recommended