+ All Categories
Home > Technology > Presentación del sistema Power View para los estudios de calidad de energía

Presentación del sistema Power View para los estudios de calidad de energía

Date post: 25-Jul-2015
Category:
Upload: innovacion-energetica-inga
View: 117 times
Download: 1 times
Share this document with a friend
Popular Tags:
12
Power Quality Analysis Power, Energy, Voltage, Power Factor and EN 50160 Analysis MEASURING INSTRUMENTS AND TESTERS MI 2792 PowerQ4 Plus
Transcript

1. MI 2792 PowerQ4 Plus Power, Energy, Voltage, Power Factor and EN 50160 AnalysisPower Quality AnalysisMEASURING INSTRUMENTS AND TESTERS 2. Power Quality AnalysisMI 2792 PowerQ4 Plus The MI 2792 PowerQ4 Plus is a power quality analyser specially designed for troubleshooting of power systems and devices. Rugged design, long battery autonomy (up to 15 hours), powerful recorders, events and alarms capture, flex current clamps as standard accessory, remote instrument control via optional GPRS modem, ability to synchronize instruments via GPS make this instrument unique troubleshooting tool. Advanced PC SW package PowerView2 enables detailed analysis of recorded data and automatic creation of professional test report. Excellent price / performance ratio, small size, advanced measurement methods and loggers are undoubted highlights of the MI 2792.MEASURING FUNCTIONS: Voltage: TRMS, peak, crest factor (4-channel); Current: TRMS, peak, crest factor (4-channel); Power (active, reactive, apparent); Power factor, cos ; Unbalance, flicker measurement; Harmonic and interharmonic analysis up to 50th harmonics, THD measurement; Energy (active, reactive, generated, consumed); Capturing and recording of power supply events (shutdowns, interruptions, swells, dips); Inrush currents monitoring and recording; Waveform displaying, snapshot and recording; Transients recording; Power quality analysis according to EN 50160; Recording up to 10 adjustable alarms; Temperature measurement.KEY FEATURES: 4 voltage channels with wide measurement range: 0 ... 1000 Vrms (CAT III / 1000 V). 4 current channels with support for automatic clamp recognition and on instrument range selection. Compliance with power quality standard IEC 61000-4-30 Class S/A. Power measurements compliance with IEC261557-12 and IEEE 1448 standards. Complete power quality analysis according to EN 50160 including signalling and interharmonics. Capture of voltage events and user defined alarms. 4-quadrant measurements (generator and load with capacitive or inductive character). Up to 524 parameters can be monitored or recorded simultaneously. 8 MB of internal memory space allows recording over 4 weeks. Powerful troubleshooting tools: transient, inrush / fast and waveform recording. On-screen displaying of trends and captured events and simultaneous recording in the background. Temperature probe for measurement of the temperature of the tested transformer, capacitor bank, etc. Possibility of remote control of the instrument or group of them via GPRS modem. Flexible clamps (without additional power supply) are included in the standard set. 15 hours of autonomous (battery) supply. Powerful PC SW PowerView2 enables downloading, view, analysis of recorded data and professional report creation. 3. Power Quality AnalysisMI 2792 PowerQ4 Plus Current clamps (I1, I2, I3, IN ) input terminals. External power socket; RS232 / GPS serial connector; USB / GPRS connector. LCD graphic display with LED backlight, 320 x 200 pixels.F1 F4 function keys. Voltage (L1, L2, L3, N, GND) input terminals.ENTER and ARROW keys move cursor and select parameters. ESC key exits any procedure or submenu.ON/OFF key turns on/off the instrument.LIGHT key turns LCD backlight on/off.5 4. Power Quality AnalysisMI 2792 PowerQ4 Plus HOW TO MANIPULATE THE INSTRUMENT:1. 2.Turn on the backlight by pressing LIGHT key,3.Scroll the instruments main menu with UP and DOWN keys,4.Enter the measurements menu by pressing ENTER key,5.Enter U,I,f menu by pressing ENTER key,6.Change view to different phase by pressing function key F3,7.Change view to scope by pressing function key F4,8.* To watch the video content click on the picture above (internet connection needed).Turn on the instrument by pressing ON/OFF key,Turn off the instrument by pressing ON/OFF key for 2 seconds.6 5. Power Quality AnalysisMI 2792 PowerQ4 Plus TYPICAL APPLICATIONS, TROUBLESHOOTING OF POWER SYSTEMS AND DEVICES:7 6. Power Quality AnalysisMI 2792 PowerQ4 Plus TYPICAL APPLICATIONS, TROUBLESHOOTING OF POWER SYSTEMS AND DEVICES:8 7. Power Quality AnalysisMI 2792 PowerQ4 Plus GPS: Typical Applications - Observing on two or more points on network By using two ore more synchronized PowerQ4 Plus instruments by means of GPS Unit, user can perform simultaneous measurement on the different network points. GPS unit assures that instruments are synchronized during EN 5010 survey, for example. Additionally the same configuration can be used for troubleshooting, for example to estimate disturbance impact on network or susceptible load. Instruments placement in that case: motor - source of disturbance (aggressor), server room - victim of disturbance, transformer - path of disturbance spreading into network. By using PowerQ4 Plus recorders (transient, inrush and waveform) user can observe disturbance spreading over the network and estimate impact under various conditions.11 8. Power Quality AnalysisMI 2792 PowerQ4 Plus GPRS: Typical Applications Modem data transfer enables remote handling of the instrument and its data. When the instrument has to be located on distant or hardly accessible place, the modem is the only practical solution for fast access to the instrument. Metrel recommend to prepare test system for verification and training before performing actual measurements at the remote place. GPRS standard set include: GPRS Modem Telit 863-PY, USB / RS232 cable, Stub Antenna, 54 mm, 12 V power supply adapter. *Optional 5 m antenna cable can be provided upon request. Requirements for remote measurements Measurement (remote) site: PowerQ4 Plus Instrument, Instrument power supply, GPRS Modem, SIM card with activated data transfer, PS/2-USB interface cable, Modem power supply, Antenna. Office (local) site: PowerView v2.0, Internet connection (http web access), Open incoming port on office router.12 9. Power Quality AnalysisMI 2792 PowerQ4 Plus POWERVIEW: PowerView software is a powerful platform for downloading, analysing recorded data and creation of power quality test reports. PC Software contains a package of functionalities needed for profound evaluation of power quality phenomena, data comparison and creation of complex test reports. It works in conjunction with Metrel new generation power quality analysers. For the instruments equipped with GPRS functionality PowerView enables remote control of the instrument as well.KEY FEATURES: User friendly interface: wide range of quick buttons, possibility to customize the environment by dragging, docking and resizing the window tabs. Structure: downloaded data is organizedinto Windows Explorer-like tree structure. Drag and drop: downloaded data can be easily organized into multiple sites and sub-site locations. Data filtering: data in a structure can be grouped by quantity or by phase. Views: depending on selected record type, different views are available (Record Information view, Trend Chart view, Table view, Waveform Scope view, Voltage Quality view, etc.) EN 50160 analysis: automatic voltage quality analysis in compliance with custom or predefined EN 50160 Power Quality criteria and quick report printing. Chart zoom: chart can be zoomed depending on selected in a table value range. Remore control: via GPRS communication remote handling of the instrument and its data can be executed. GPS synchronization: simultaneous13measurement on the different network points by using 2 or more synchronized instruments. On-line monitoring: when instrument is connected with PC, real-time observing of signals and parameters is possible via PowerView while instrument is measuring / recording in the background. Export of test results: test results can be exported to other programs (MS Excel, MS Word). Reports: automatic generation of test reports from the selected views and data with attached graphs. SW update: PowerView checks for new versions of the application and downloads updates from the Internet if necessary. 10. Power Quality AnalysisMI 2792 PowerQ4 Plus VIDEO PRESENTATION OF PC SOFTWARE:* To watch the video content click on the picture above (internet connection needed).14 11. Power Quality AnalysisMI 2792 PowerQ4 Plus EXAMPLE OF TEST REPORT: 15 12. Power Quality AnalysisMI 2792 PowerQ4 Plus STANDARD SET: MI 2792 Instrument PowerQ4 Plus 1-phase flexible current clamps 3000 / 300 / 30 A (A 1227), 4 pcs Test probe, red, 2 pcs Test probe (CAT II), red, 3 pcs Test probe (CAT II), black Crocodile clip, black Crocodile clip, green Crocodile clip, red, 3 pcs Voltage measurement lead, red, 3 pcs Voltage measurement lead, black Voltage measurement lead, green Temperature probe PC SW PowerView2 RS232 and USB cables Power supply adapter 1.2 V NiMH rechargeable battery, 6 pcs Soft carrying bag Instruction manual Calibration certificate16


Recommended