PressureControl Valves
Fast, Secure, Inexpensive
TECHNICAL RANGE
MF1 20mm 400KPA PA3.132 MF3 22mm 400KPA PA6.342 MF3 15mm 400KPA PA6.341
MF2 15mm PA4.331400KPA Closy 20mm PA1.1400KPA
0
10
20
30
40
50
60
70
80
90
100
10 20 30 40 50 100 150 200 250 300 350 400
Flow Pressure
L/M
in
FlowPressure
MF1 20mm400KPA PA3.132
MF3 22mm400KPA PA6.342
10
20
30
40
50
100
150
200
250
300
350
400
16
20
24
26
28
38
48
54
60
64
70
74
22
28
32.5
36
38
50
60
68
76
82
88
92.5
MF3 15mm400KPA PA6.341
18
22
24
26
28
38
44
50
56
60
66
70
MF2 15mmPA4.331 400KPA
14
18
20
24
26
36
42
48
52
57
62
66
Closy 20mmPA1.1 400KPA
16
22
26
29
32
44
56
64
74
80
86
92
Pressure Cotrol Valves (PCV)The pressure control valves effectively reduce high mains pressure, resulting in less water delivery at
taps. The expansion relief pressure control functions are all situated on one spindle, so there is no chance
of conflicting settings causing the valve to unnecessarily relieve pressure and thereby waste water.
Description:
Code:
400kPa system pressure with integral expansionrelief valve. Stainless steel seat & strainer.PA1.1
KWIKFLO
Description:
Code:
100kPa system pressure with integral expansionrelief valve and vacuum breaker. Stainless steelseat & strainer.PA1.1L
CLOSY
Description:
Code:
200kPa system pressure with integral expansionrelief valve and vacuum breaker. Stainless steelseat & strainer.PA1.1L+
CLOSY
Description:
Code:
400kPa system pressure with integral expansionrelief valve. Stainless steel seat and strainer(double mesh). ¾” BSP male iron inlet and outletcap and lining couplings.PA3.132
MASTERFLO 1
Description:
Code:
Consisting of 1 x PA3.132, 2 x PB6.302 and1 x ¾” BSP female iron valvecock.PA3.132PK
GEYSER VALVE PACK
SANS198
Description:
Code:
400kPa system pressure with integral expansionrelief valve. 22mm Copper to Copper. Stainlesssteel seat & strainer (double mesh).PA3.332
MASTERFLO 1
Description:
Code:
Consisting of 1 x PA3.332, 2 x PB6.303 and1 x 22mm Copper to Copper inlet & outlet 22mmvalvecock.PA3.332PK
GEYSER VALVE PACK
Description:
Code:
With 1 x PA3.132, ballcock, funnel, box with lid,strainer, 2 x PB6.303 vacuum breakers. ¾” BSPinlet & outlet.PA5.1
MASTER BOX
Description:
Code:
With 1 x PA3.132, ballcock, funnel, box with lid,2 x PB6.303 vacuum breakers. Kent M /H WaterMeter.PA5.1M
3
MASTER METER BOX
Description: 100kPa system pressure with integral expansionrelief valve. 15mm Copper to Copper. Stainlesssteel strainer.
MASTERFLO II
SANS198
Description:
Code:
200kPa system pressure with integral expansionrelief valve. 15mm Copper to Copper. Stainlesssteel strainer.PA4.321
MASTERFLO II
Description:
Code:
400kPa system pressure with integral expansionrelief valve. 15mm Copper to Copper. Stainlesssteel strainer.PA4.331
MASTERFLO II
Description:
Code:
Consisting of 1 x PA4.331, 2 x PB6.301 and1 x 15mm valvecock.PA4.331PK
Copper to Copper
GEYSER VALVE PACK
Description:
Code:
400kPa system pressure with integral expansionrelief valve. Stainless steel seat & strainer (doublemesh). 22mm Copper to Copper.PA4.332
MASTERFLO II
Description:
Code:
Consisting of 1 x PA4.332, 2 x PB6.303 and1 x 22mm valvecock. Acetyl valveseat.PA4.332PK
Copper to Copper
GEYSER VALVE PACK
SANS198
Description:
Code:
100kPa system pressure with integral expansionrelief valve. 22mm + 2 X PB6.303.Stainless steel strainer. Acetyl valve seat.PA4.712
Copper to Copper
MASTERFLO II
Description:
Code:
Consisting of 1 x PA4.712, 2 x PB6.303 and1 x 22mm valvecock. Acetyl valveseat.PA4.712PK
Copper to Copper
GEYSER VALVE PACK
Description:
Code:
200kPa system pressure with integral expansionrelief valve. 2 X PB6.303. 22mm Copper to Copper.Stainless steel strainer.PA4.722
MASTERFLO II
Description:
Code:
300kPa system pressure with integral expansionrelief valve. Stainless steel strainer, acetyl valveseat. 2 X PB6.303. 22mm Copper to Copper.PA4.732
MASTERFLO II
SANS198
Description:Code:
400kPa Pressure control valve cartridge spare part.C-PA6.832
SPARE CARTRIDGE 400KPA
MF3 15mm 400kPa MF3 22mm 400kPa
Flow Pressure
100
200
300
400
500
600
MF3 15mm 400kPa
32
46
58
68
76
82
MF3 22mm 400kPa
44
64
78
90
100
108
Flow Pressure
0
20
40
60
80
100
120
100 200 300 400 500 600
L/m
in
15MM 400KPA PA6.341/ 22MM 400KPA PA6.342
Features and Benefits:
400kPa system pressure with integral expansion relief valve.Copper to Copper SANS 198
MASTERFLO III
Available in 400kPa and 600kPa pressure ratings.Connection size: 15mm and 22mm for copper tube systems to facilitate ease and lowcost installation.
Complete with expansion relief valve.Operating cartridge and expansion relief valve can easily be removed from the body.Hand removable working cartridge, no special tools required to service the valve.
Excellent flow rates.
SANS198
Non-corrosive valve seat.No additional expansionrelief valve required.Cannot use MLP or SLP foroutside applications.This is applicable toPB6.341 (15mm) & PB6.342I.T.O outlet.Integral expansion relief valve.Stainless steel strainer.
Copper to Copper inlet and outlet,15mm & 22mm respectively.No special tools required toreplace the cartridge.PPSU (polyphenylsulfone)valve seat.DZR brass die cast.Ø15mm Copper to Copperexpansion outlet.System pressure: 400kPa.Maximum inlet pressure: 2500kPa.
Includes:
Masterflo III pressurecontrol valve.Integral expansion relief valve.400kPa cartridge withstainless steel strainer.
Replaceable cartridge C-PA6.832.Cap nut 64XS-22.Compression ring D-65XS-22.
Spares:
600kPa system pressure with integral expansion relief valve.Copper to Copper. SANS 198.
MF3 15mm 600kPA MF3 22mm 600kPa
Description:Code:
600kPa Pressure control valve cartridge spare part.C-PA6.862
SPARE CARTRIDGE 600KPA
52
66
78
90
100
110
100
200
300
400
500
600
40
54
64
74
82
88
Flow Pressure MF3 15mm 600kPa MF3 22mm 600kPa
Flow Pressure
L/m
in
0
20
40
60
80
100
120
100 200 300 400 500 600
15MM 600KPA PA6.361/ 22MM 600KPA PA6.362
Includes:
Masterflo III pressure control valve.Integral expansion relief valve.600kPa cartridge with stainless steel strainer.
Features and Benefits:
Replaceable cartridge C- PA6.862.Cap nut 64XS-22.Compression ring D-65XS-22.
Spares:
SANS198
Non-corrosive valve seat.No additional expansion relief valve required.Cannot use MLP or SLP for outside applications.This is applicable to PB6.341 (15mm) & PB6.342 I.T.O outlet.Integral expansion relief valve.Stainless steel strainer.Copper to Copper inlet and outlet, 15mm & 22mm respectively.No special tools required to replace the cartridge.PPSU (polyphenylsulfone) valve seat.DZR brass die cast.Ø15mm Copper to Copper expansion outlet.System pressure: 600kPa.Maximum inlet pressure: 2500kPa.
PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS
CAUTION / WARNING:All installations of products and systems must be in accordance with the applicable
SANS regulations, specifications and standards.
Installations, servicing and maintenance should be done by accredited serviceproviders only.
CAUTION:The pressure control valve must be compatible with the pressure rating of thehot water cylinder and the temperature and pressure relief valve (safety valve)
Hot and Cold water pressure must be balanced (equal pressure) to all mixers, mixing points,showers and hand showers. This is achieved by taking the cold water supply from thedownstream side of the pressure valve.
A. Balanced Pressure
B. Valve Identification
100kPa valve (Blue cap)200kPa valve (Black cap)400kPa valve (Red cap)600kPa valve (Green cap)
C. Expansion Relief Drain Pipe
Be piped in such a manner to drain downwardsNot be interconnected with the safety valve (T&P) drain pipeNot to discharge in the hot water cylinder drip trayDischarge where flow is visibleBe protected against frostHave minimal bends/ fittings
D. General Requirements
All pipes must be flushed clean before putting the system into operation.Waterflow must be in the direction of the arrow marked on the valve body.The valve must be easily accessible for maintenance/ servicing.The relief drain connection must allow for the relief drain pipe to be pulled to one side whenremoving the cartridge. Allow a minimum distance of ±100mm for cartridge removal.Do not install a stop-cock or non-return valve between the hot water cylinder and the pressurecontrol valve.Do not install a stop-cock between the hot water cylinder and the vacuum breakers on the hotand cold sides.Supply pipes adequately sized.Please ensure to make use of copper tube with the installation.Max inlet pressure 2,500kPa.System pressure according to the rating of the hot water cylinder, i.e. only use a 400kPa PCV witha 400kPa rated hot water cylinder and a 600kPa PCV with a 600kPa rated hot water cylinder.
PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS
INSTALLATION OF VALVE AT THE INLET OF THE HOUSE
E. Valve
Valve is pre-set by the factory and does not require any additional adjustments and settings
Integral expansion relief valve
Integral stainless steel strainer
Non-corrosive valve seat
F. Connection TypesPlease take note that PCV ranges consist of a variety of connection types and sizes:
15mm22mm3/4"BSP Female connection end
Copper to CopperCopper to Copper
CLEANING AND MAINTENANCE
Q. When to service?
Insufficient flow rateContinuous drip through the expansion drainFlush the cartridge if any dirt or particles are stuckReplace the cartridge if requiredTighten with your hands or a suitable plumbing tool - DO NOT OVERTIGHTEN THE CAP
PRESSURE CONTROLG VALVES - BASIC INSTALLATION REQUIREMENTS
WARRANTY STATEMENT
All Cobra products are backed by a guarantee against defective materials and workmanship duringthe manufacturing process. Our products are backed by a Service Department and, most importantly,a full range of replacement parts is available from plumber's merchants.
The same commitment that goes into designing and manufacturing a quality product also goes intoensuring the quality of the service back-up at every stage of design and installation.
FAULT FINDER AND PROBLEM SOLVING
COMPLAINT POTENTIAL FAULT WHAT TO DO
Excessive water flow atexpansion drain (hot water)
Unbalanced pressure Balanced pressure
Excessive leak /continuous drip
Geyser thermostat faulty;Foreign matter on valve seat;Valve seat damaged
Clean cartridge / valve;Replace cartridge;Check for correct flow indirection of the arrow
Water hammer duringvalve opening / closing
Loose piping;Air-lock;System pressure drop;Excessive water velocity
Secure piping;Ensure correct pipe sizing;
Vibration in system Faulty cartridge;Pipe undersized;Faulty washer in taps/ mixers
Replace cartridge;Ensure correct pipe sizing;Locate and replace washers
THE WARRANTY WILL BE APPLICABLE FOR A PERIOD OF
2 YEARS AGAINST COBRA FACTORY FAULTS.