Tel: 1.716.684.4500 • USA Toll Free: 1.800.223.2389 • Email: [email protected] • Website: www.conaxtechnologies.com
Process Analyzer Sample Probe Assembly (SPA)with Conax Packing Gland (PG) Compression Seal Fitting
For Unique Applications...• Process analyzing • Flare stack emissions• Chemical injection quills• Waste water analysis• Potable water quality sampling• Hot tapping liquid or gas streams
Features & Options...• Plasma welded stop collar• Optional Retaining Chain Kit• Wake frequency calculations• Various probe ends and valve
types available
Sample Probe AssemblyThe Conax Technologies’ Sample Probe Assembly (SPA) is used to hot-tap a probe into a process through a process isolation valve.
Temperature and Pressure RatingsRefer to the appropriate sections of Conax Catalog 5001C for temperature and pressure ratings for static conditions. Pressure ratings are reduced when the sealing gland cap is loosened to allow for the insertion or extraction of the Sample Probe.
Material Options• Optional materials for the Sample Probe Assembly
and the Conax Technologies’ Packing Gland (PG) body (wetted components) are available. Available options include 316L SST, 316 NACE SST, 316L CRN, Monel 405, Hastelloy C276 and Inconel 600.
• Sample Probe Assemblies and/or PG Gland bodies can be supplied with a Silcolloy™ 1000 (Silcosteel®-CR) or SilcoNert™ 2000 (Siltek®/Sulfinert®)coating.
• Standard Sealants are Teflon®, PEEK™, and Grafoil®. Other sealants are available for special applications.
Conax Packing Gland (PG)
Optional Retaining Chain Kit
Conax Sample Probe Assembly with Plasma Welded Stop Collar
Bonda Relief Counterbore
SAMPLE PROBE DIA. / TUBING (mm) SAMPLE PROBE DIA. / PIPE (mm)
Model NPT Size
0.250(6.35)
0.375(9.53)
0.500(12.70)
0.625(15.88)
0.750(19.05)
1.000(25.40)
1/8".405" OD(10.29)
1/4".54" OD(13.72)
3/8".675" OD(17.15)
1/2".84" OD(21.34)
3/4"1.05" OD(26.67)
1"1.315" OD(33.40)
1.25"1.66" OD(42.16)
1.50"1.90" OD(48.25)
PG2 1/4" XPG4
1/2”X X X
PG5(PTM4) X X X X XPG5 3/4" X X X X X X X X
PG5(PTM6)1”
X X X X X X X XPG6 X X XPG7 1-1/4" X X XPG8 1-1/2" XPG9 2" X X
How to Configure the Model Number of an SPA Assembly
OD (mm)
WALL (mm) ID (mm) MATERIAL
.250”(6.35)
.025” (.64) .200” (5.08) S304
.035” (.89) .180” (4.57) S304
.025” (.64) .200” (5.08) S316
.035” (.89) .180” (4.57) S316
.035” (.89) .180” (4.57) MONEL 400
.035” (.89) .180” (4.57) HAST C276
.375”(9.53)
.040” (1.02) .295” (7.49) S304
.065” (1.65) .245” (6.22) S304
.040” (1.02) .295” (7.49) S316
.058” (1.47) .259” (6.58) S316
.065” (1.65) .245” (6.22) MONEL 400
.035” (.89) .305” (7.75) HAST C276
.065” (1.65) .245” (6.22) HAST C276
OD (mm)
WALL (mm) ID (mm) MATERIAL
.500”(12.70)
.035” (.89) .430” (10.92) S304
.049” (1.25) .402” (10.21) S304
.065” (1.65) .375” (9.53) S304
.120” (3.05) .260” (6.60) S304
.049” (1.25) .402” (10.21) S316
.065” (1.65) .370” (9.40) MONEL 400
.049” (1.25) .402” (10.21) HAST C276
.625”(15.88) .065” (1.65) .495” (12.53)
S304
S316
.750”(19.05)
.095” (2.41) .560” (14.22) S316
.065” (1.65) .620” (15.75) MONEL 400
1.000”(25.40) .120” (3.05) .760” (19.30) S316
Tubing is seamless or welded and annealed.
Standard Conax Packing Gland (PG) Compression Seal Fitting model numbers and configurations apply. Compression seal fittings are supplied loose unless otherwise indicated. Example model number: SPA/PG5-500-A-T/500X120W(S304)-45-1-36
Standard Tube Sizes
Optional Retaining Chain Kit
Example:
— “C
” Con
nect
ion
Thre
ad S
ize
— S
ampl
e Pr
obe
Diam
eter
18–0005–025N–25–12
— C
hain
Len
gth
— D
rawi
ng P
refix
The Conax Retaining Chain Kit is constructed from 300 series SST and is specifically designed to function with the Conax Process Analyzer Sample Probe Assembly (SPA) utilizing a Conax Packing (PG) Compression Seal Fitting.
Catalog Numbering System
Drawing Prefix
025N = .25 NPT
038N = .38 NPT
050N = .50 NPT
075N = .75 NPT
100N = 1.00 NPT
“C” Connection Thread Size (2 decimal places NPT)
N
25 = .250” (6.35 mm)
38 = .375” (9.53 mm)
50 = .500” (12.70 mm)
63 = .625” (15.88 mm)
75 = .750” (19.05 mm)
10 = 1.000” (25.40 mm)
Sample Probe Diameter
Chain Length (in whole inches)
18 0005
Chemical Injection • Online Retraction/Insertion • Water Quality Sampling
Installation Instructions for the Conax Retaining Chain KitTo Adjust Safety Chain
1. Unscrew threaded connector link at process side of probe.
2. Take up all extra links and loop over the threaded connector.
3. Screw threaded connector back together and wrench tighten. 5 in-lbs recommended (.56 Nm)
To Install Shaft Collars:
1. Loosen collar screws2. Place collars and back retaining washer over probe as
shown3. Tighten collar screws.
• For 1/4” probe tighten - 8 in-lbs recommended (6.35 mm probe tighten - .90 Nm)
• For 3/8” probe tighten - 15 in-lbs recommended (9.52 mm probe tighten - 1.70 Nm)
• For 1/2” probe tighten - 28 in-lbs recommended (12.7 mm probe tighten - 3.16 Nm)
• For 5/8” probe tighten (45 in-lbs recommended (15.875 mm probe tighten - 5.08 Nm)
*See below and page 18 of the Conax Compression
Seal Fitting Catalog 5001C for more information.
To Request a quote, please email [email protected] or call 1.800.223.2389 or see page four to download the SPA quote request form.
Hot Tapping Liquid or Gas Streams • Flare Stack Emission Sampling
Other sizes and materials available on request. All Conax PG glands are available with an optional welded or threaded ASME/ANSI Raised Face Flange mount.
Conax PG Compression Seal Fittings
Product Name
Compression Seal Fitting Used *
if none indicate “X”TubeOD
TubeWall
Tube Material(S304, S316,
M405, HC276, I600)
“A”Tube End Angle
(90°, 60°, 45°, 30°)
“B” Dimension
(1/4” increments 1=1/4”)
“L” Overall Tube Length
(inches)SPA PG5-500-A-T 500 120W (S304) 45 1 36
Standard diameter for the welded stop collar is .125” larger than the sample probe. Specials available upon request.
© 2010 Conax Technologies Bulletin 6066 04/10
User Cautions
2300 Walden AvenueBuffalo, New York 14225, USA
Toll free in the USA at 1-800-223-2389Fax: 716-684-7433 • Phone: 716-684-4500
E-mail: [email protected]: www.conaxtechnologies.com
www.conaxtechnologies.comCatalog 5001C, Complete Guide to Compression Seal Fittings
www.conaxtechnologies.com
Silcosteel-CR and Sulfinert coating are registered trademarks of SilcoTek Corporation. • PEEK is a trademark of Victrex. Teflon is a registered trademark of E.I. DuPont de Nemours Company. • Grafoil is a registered trademark of UCAR International, Inc.
Sample Probe Assembly • The end user must take the necessary safety precautions when loosening the cap of the Conax sealing gland when inserting
or extracting the Sample Probe into pressurized environments. • The end user is responsible to control any leakage of process that may occur during insertion or extraction of the Sample
Probe. • The end user is responsible for determining the appropriate Sample Probe material, diameter and wall thickness for the
process environment and flow rates. • Conax Technologies is not responsible for the operation of the Conax Packing Gland (PG) assembly once the cap is
loosened to allow for the insertion or extraction of the Sample Probe. • Typically, when properly installed, the angled Sample Probe tip should have the long side upstream. This reduces the
particulates entering the Sample Probe and into the process analyzer filter. • The Sample Probe immersion length should be designed to obtain a process sample close to the center third of the pipe.• It is suggested that the end user mark the Sample Probe end with an indelible ink marker relative to the angled end for
proper orientation into the process.
Retaining Chain Kit• Retaining chain assembly is not intended to assist or control the insertion/extraction of the sample probe. The operator is
responsible for restraint of the sample probe at all times. • Chain must be kept as short as possible to function properly. Some minor slack in the chain will be present when sample
probe is inserted. The retaining chain kit is not intended for impact loads. If it is subject to an impact load, all parts must be inspected/replaced as required.
• Periodically inspect restraint system. Re-torque probe collar and threaded connector. Replace parts as necessary. • Maximum design pressure for the retaining chain kit is 500 psig. (≤ .500” (12.70mm) Sample Probe diameter.)• Prior to installing the SPA gland into the process valve port, install the front retaining washer over the PG gland pipe thread.
Watch our Sample Probe Animation!
Please visit our website to download literature, request a quote or even watch a video for our Sample Probe Assembly.
You can also find information on other compression seal fittings, temperature sensors and mineral insulated cable products.
Request a quote using the Sample Probe Quote Request Form - Bulletin 6066DS