1 Product Innovation Report How Corrosion on the Negative Battery Terminal Destroys ECIMs Test-proven Field Retrofit Solution Offered 27 May 2014 Hood Tech Proprietary 5/27/2014 Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered
Transcript
Page 1: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

1

Product Innovation ReportHow Corrosion on the Negative Battery Terminal Destroys ECIMs

Test-proven Field Retrofit Solution Offered

27 May 2014

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 2: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Applicability

• Mark 4 Commercial Launcher• HTL4.1 (STUAS Launcher)

Hood Tech Proprietary 5/23/2014

Negative Battery Lead Corrosion Destroys ECIMs; Field Retrofit Solution

Offered

2

Page 3: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

3

Problem Report• NSW (T3) reports melted blue wires inside the ECIM and

uncommanded system shut-down following Compressor start attempt.

• Replacing ECIM resulted in melted ECIM wires on the new ECIM.

• Upgrading compressor start circuit at compressor did not help; a third ECIM was destroyed with the same symptoms as the first two.

• The site is located near salt water. Battery terminal corrosion and evidence of arcing reported from the site, which confirms the root cause analysis.

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 4: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Field Failure (photo 1 of 5)

4Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 5: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Field Failure (photo 2 of 5)

5Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 6: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Field Failure (photo 3 of 5)

6Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 7: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Field Failure (photo 4 of 5)

7Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 8: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Field Failure (photo 5 of 5)

8Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 9: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

9

Root cause:•Corrosion build-up prevents compressor start current from returning directly to negative battery terminal. Instead, it passes first through ECIM, returning via trailer chassis and generator negative battery leads.

•Overloaded blue wire shorts with leads carrying +12VDC or +24VDC inside ECIM, which causes internal voltage droop and system shut-down.

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 10: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Hood Tech Re-enactmentCompressor Start Commanded with Wiring Fault (simulated corrosion) as shown in Previous Slide.

>100 amps observed through clamp-on ammeter.

10Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 11: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Compare Damagewith Fielded Launcher. Image taken after 5-seconds of “Compressor-Start” Commanded

11

+24V (orange)Shorted to-12V (blue), causing systemto shut down

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 12: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Compare Damage

12Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Page 13: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

13

Test-proven RemedyArrange negative battery leads as shown and add a 10A fuse to protect

ECIM from large start currents demanded by compressor starter.

Note: HTL4.2 ECIMHas introduced this fuse protection inside the ECIM

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution

Offered

Page 14: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

Retrofit Kit

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

14

Page 15: Product Innovation Report - hoodtechmechanical.comhoodtechmechanical.com/doc/Negative Battery Lead... · 3 Problem Report • NSW (T3) reports melted blue wires inside the ECIM and

As Installed

Hood Tech Proprietary 5/27/2014

Negative Battery Terminal Corrosion Destroys ECIMs; Field Retrofit Solution Offered

Hood Tech Proprietary 15

Stainless steel clamping bolt grounds negative battery terminal to trailer chassis

Isolated and fuse-protected post terminates ECIM –battery lead

ECIM -battery lead(Not included)


Recommended