Quick Start Guide
Version: 1.0
Date: Nov. 2018
ProRF
Overview
1
LED indicator
Reset Button
Name Description
LED indicator
� Green flashes once in a second: verifying, enrollment or deletion status.
� Green glows continuously for 2 seconds: Authentication success
� Red glows continuously for 2 seconds: Authentication failure
Reset � Reboot the device: press the reset button and hold it for 3 seconds.
Magnetic Tamper
Switch
� Restore factory setting
� Tamper Switch: keep the magnetic tamper switch on back plate, or it will
trigger the tamper alarm.
Magnetic tamper
switch
Cables and connectors
48
5B
48
5A
GN
DT
XD
RX
DG
ND
Wd
1
BE
EP
GL
ED
RL
ED
1W
D1
1W
D0
GN
D
12
VO
UT
GN
D
Wd
0
+1
2V
RJ4
5-6
RJ4
5-3
RJ4
5-2
RJ4
5-1
AU
X
BE
L-
BE
LL
+
GN
D
BU
TN
OC
OM
NC
AL
-
SE
N
AL
+
GN
D
Input: DC12V 3A
Operating Temperature: 20 ~65℃ ℃
Waterproof: IP65
Made in China
2
DESCRIPTION WIRE
RJ45 6-
RJ45 3-
RJ45 2-
RJ45 1-
AUX
GND
BELL-
BELL+
SEN Yellow
Black
Brown
Green
Orange
Blue
PIN
A1
A2
A3
A4
B1
B2
B3
B4
B5
B6
B7
GND
BUT
Black
Orange+White
Green White+
Green White+
Orange+White
NO
COM
NC
AL-
AL+
485B
485A
GND
TXD
Yellow
White
Gray
Black
Pur lep
Green
Orange
Blue
B8
B9
B10
B11
B12
C1
C2
C3
C4
C5
C6
RXD
GND Black
Gray
Pur lep
WD1
WD0
WhiteC7
C8 Green
DESCRIPTION WIRE
BEEP
GLED
RLED
IWD1
IWD0
GND
12VOUT
Gray
Black
Pur lep
Green
Blue
PIN
D1
D2
D3
D4
D5
D6
D7
E1
E2
GND
+12V
Black
White
Red
Red
1 42 3
A B
1 42 3 5 6 7 8
C D E
10 11 121 42 3 5 6 7 8 9
1 42 3 5 6 7 1 2
3
Installation
①
②
1) Paste the mounting template
sticker on the wall, and drill holes
according to the mounting paper.
2) Fix the back plate on the wall using
wall mounting screws.
3) Attach the device to the back plate. 4) Fix the device to the back plate
with a security screw.
4
Power Connection
12V AdaptorDC
Recommended power supply
1)12V ± 10%, at least 500mA.
2)To share the power with other devices, use a power supply with higher current ratings.
E2
E1GND
+12V DC
E2
E1GND
+12V DC
5
Ethernet Connection
Ethernet Cable
Network Cable Adaptor
1) The device connects to the computer over an Ethernet through a switch.
2) The device directly connects to the computer.
876
RJ 45 54321
Default IP address: 192.168.1.201
Subnet mask: 255.255.255.0
Ethernet Cable
Lock Relay Connection
6
Device not sharing power with the lock
The system supports Normally Opened Lock and Normally Closed Lock.
T Normally Closed Lock below:ake as an example
Normally Closed Lock
+12VDC
GND
! Maximum 30V 2A input.
NC
COM
FR107 Diode
-+
B10
B9
7
Lock Relay Connection
Device sharing power with the lock
Normally Closed Lock+12VDC
! Maximum 12V 2A input.
FR107 Diode
-+
NC
GND
COM
B10
B6
B9
E2
Notes:
1.The system supp The NO LOCK (normallyorts Normally Opened Lock and Normally Closed Lock.
opened at power on) is connected with ‘NO’ and ‘COM’ terminals, and the NC LOCK (normally closed at
power on) is connected with ‘NC’ and ‘COM’ terminals.
2. When electrical lock is connected to the Access Control System, you must add one FR107 diode in
parallel equipped in the package) to prevent the self-inductance EMF from affecting the system.(
Door Sensor, Exit Button, Bell & Alarm Connection
8
Door Sensor
SEN
GND
BUT
GNDB6
B5
B6
B7
Bell+-
GND +12V
B4
B3BELL-
BELL+
Alarm
Alarm's power switch
- ++-
B12
B11AL-
AL+
Exit Button
R 232 CS onnection(optional)R 232 CS onnection(optional)
9
Rs232 CableSerial Printer
C5
C4
C6
TXD
RXD
GND
RS485 Connection
C1
C2485B
485A
RS485 Reader
C3GND
Power supply
Lock
+
+-
-
C8
E1GND
E2
C7W 0D
W 1D
Wiegand Output Connection
Security Relay Box
10
After a successful verification, the device will send Wiegand signals to the SRB access controller,
then the SRB will output relay signals to trigger the relay to unlock the door.
+12V12V
W 0D
W 1D
COM
NC
GND
GNDNO
BUT
D5
E1GND
E2
D4I 0WD
I 1WD
+12V
Wiegand Reader
Wiegand Input Connection
Exit Button
Alarm
Doorbell
Smokedetector
11
Lock TCP/IP
Exit Button
Door Sensor
Card Reader
Standalone Installation
Quick Start Operations
12
Suppose the device is connected with PC and the software (ZKBiosecuty 3.1.5.0) is installed.
Double-click the ZKBiosecuty icon on the desktop to open.
Click [Access Device] > [Device] > [New], enter device
name and IP Address of the device and click [OK]. The
following interface will be shown:
Add Device
13
Add Personnel1. Click [Personnel] > [Personnel] > [New] to add persennel information and set access levels .
Note:
1. IP addresses of the server (PC) and the device must be in the same network segment. The
default IP Address of the device is 192.168.1.201.
2. Please set the device type to standalone device.
3. Once IP address and communication password missing, please refer Reset function.
14
Sync All Data to Device
The system will synchronize the data to the device, including door information, access control
levels (personnel information, access control time zones), and so on. Select device, click
[Synchronize All Data to devices] and click [OK] to complete synchronization.
User can set Access Control Time Zones, Access Control Holiday, Door Settings, Access Levels,
Personnel Access Levels and so on in Access Control interface. For more details, please refer
the user manual and the software instruction.
Access Control Setting
Forgot the password/IP address?
Trigger the magnetic tamper switch three times quickly
within 30-60 seconds of the device start-up. (After
operation successfully, beep sound continue and
device reboot automatically.)
This process restores factory settings, such as device
password, IP address, etc.
Tips
www.zkteco.eu
© . . .Copyright 2018 ZKTeco Inc ZKTeco Logo is a registered trademark of ZKTeco or a related company All other product and company names mentioned are used for
. . .identification purposes only and may be the trademarks of their respective owners All specifications are subject to change without notice All rights reserved