Version 8.3 | January 2014 | DOC2739A
Release Notes
RealPresence Collaboration Server RMX 1500 / 1800 / 2000 / 4000
© 2014 Polycom, Inc. All rights reserved.
Polycom, Inc. 6001 America Center Drive San Jose CA 95002 USA
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc. Under the law, reproducing includes translating into another language or format.
As between the parties, Polycom, Inc., retains title to and ownership of all proprietary rights with respect to the software contained within its products. The software is protected by United States copyright laws and international treaty provision. Therefore, you must treat the software like any other copyrighted material (e.g., a book or sound recording).
Every effort has been made to ensure that the information in this manual is accurate. Polycom, Inc., is not responsible for printing or clerical errors. Information in this document is subject to change without notice.
2
Trademark Information POLYCOM® and the names and marks associated with Polycom's products are trademarks and/or service marks of Polycom, Inc., and are registered and/or common law marks in the United States and various other countries.
All other trademarks are the property of their respective owners.
Patent Information The accompanying product may be protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc.
This document provides the latest information for security-conscious users running Version 8.3 software.The information in this document is not intended to imply that DoD or DISA certifies Polycom RMX systems.
End User License Agreement
Use of this software constitutes acceptance of the terms and conditions of the Polycom® RealPresence® Collaboration Server (RMX) 1500/1800/2000/4000 system end-user license agreements (EULA).
The EULA for your version is available on the Polycom Support page for the Polycom® RealPresence® Collaboration Server (RMX®) 1500/1800/2000/4000 system.
This software has not achieved UC APL certification.
RMX Release Notes Version 8.3
Polycom, Inc. 3
Regulatory Notices
Warning
Warning
• No user-serviceable parts inside. Do not open.
• The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device
• This equipment must be earthed. Do not power this equipment if the integrity of themains earthing conductor cannot be verified
• Only trained and qualified personnel should be allowed to install, replace, service or repair this equipment
• To prevent system overheating do not operate in an ambient temperature exceeding 40° C / 104° F
• Installation of this equipment must comply with local and national electrical codes.
Environmental
This product is compliant with the requirements of the recast RoHS Directive 2011/65/EU. Information can be obtained from Polycom Ltd, 270 Bath Road, Slough, Berkshire, SL1 4DX, UK or via: [email protected]
Information on recycling can be found at: www.polycom.com/WEEE
Disposal of this equipment should be carried out in accordance with local environmental guidelines and regulations for waste. For further information please contact: [email protected]
Batteries
Below is a listing of batteries that could be present in the product:
Description:Internal CMOS battery
Type:CR2032 Lithium Coin Cell
Weight:3.3g
Batteries used in this product are in compliance with EU Battery Directive 2006/66/EC.
Batteries in this product are not based on mercury, lead or cadmium technologies.
Batteries in this product are not intended to be replaced or removed by the user
Additional information on the safe use and recycling of batteries can be found at: www.polycom.com/batteries
RMX Release Notes Version 8.3
Polycom, Inc. 4
United States Federal Communication Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Modifications: Any modifications made to this device that are not approved by Polycom, Inc. may void the authority granted to the user by the FCC to operate this equipment.
Industry Canada (IC)
This Class [A] digital apparatus complies with Canadian ICES-003
Cet appareil numerique de la classe [A] est conforme a la norme NMB-003 du Canada
European Economic Area (EEA)
Česky [Czech]: Polycom (UK) Ltd tímto prohlašuje, že tento Polycom RMX je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
Dansk [Danish]: Undertegnede Polycom (UK) Ltd erklærer herved, at følgende udstyr Polycom RMX overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Deutsch [German]: Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät Polycom RMX in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet.
Eesti [Estonian]: Käesolevaga kinnitab Polycom (UK) Ltd seadme Polycom RMX vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
English: Hereby, Polycom (UK) Ltd. Declares that this Polycom RMX is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Español [Spanish]: Por medio de la presente Polycom (UK) Ltd declara que el Polycom RMX cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Ελληνική [Greek]: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Polycom (UK) Ltd ∆ΗΛΩΝΕΙ ΟΤΙ Polycom RMX ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ.
Français [French]: Par la présente Polycom (UK) Ltd déclare que l’appareil Polycom RMX est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
RMX Release Notes Version 8.3
Polycom, Inc. 5
Italiano [Italian]: Con la presente Polycom (UK) Ltd dichiara che questo Polycom RMX è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Íslenska (Icelandic): Hér með lýsir Polycom (UK) Ltd yfir því að Polycom RMX er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC
Latviski [Latvian]: Ar šo Polycom (UK) Ltd deklarē, ka Polycom RMX atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.
Lietuvių [Lithuanian]: Šiuo Polycom (UK) Ltd deklaruoja, kad šis Polycom RMX atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.
Nederlands [Dutch]: Hierbij verklaart Polycom (UK) Ltd dat het toestel Polycom RMX in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
Malti [Maltese]: Hawnhekk, Polycom (UK) Ltd, jiddikjara li dan Polycom RMX jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Magyar [Hungarian]: Alulírott, Polycom (UK) Ltd nyilatkozom, hogy a Polycom RMX megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Norsk [Norwegian]: Polycom (UK) Ltd erklærer herved at utstyret Polycom RMX er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
Polski [Polish]: Niniejszym Polycom (UK) Ltd oświadcza, że Polycom RMX jest zgodne z zasadniczymi wymaganiami oraz innymi stosownymi postanowieniami Dyrektywy 1999/5/WE.
Português [Portuguese]: Polycom (UK) Ltd declara que este Polycom RMX está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
Slovensko [Slovenian]: Polycom (UK) Ltd týmto vyhlasuje, že Polycom RMX spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.
Slovensky [Slovak]: Polycom (UK) Ltd týmto vyhlasuje, že Polycom RMX spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.
Suomi [Finnish]: Polycom (UK) Ltd vakuuttaa täten että Polycom RMX tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Svenska [Swedish]: Härmed intygar Polycom (UK) Ltd att denna Polycom RMX står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
A full copy of the Declaration of Conformity can be obtained from Polycom Ltd, 270 Bath Road, Slough, Berkshire, SL1 4DX, UK.
European Economic Area (EEA)
RMX Release Notes Version 8.3
Polycom, Inc. 6
Taiwan BSMI EMC statement
Japan VCCI EMC statement
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Worldwide EMC statement
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Optional ISDN interface card
If the above is fitted to the system then the following statements also apply;
United States Federal Communication Commission (FCC)
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the ISDN card itself is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The following USOC, FIC and SOC codes are applicable to this equipment;
USOC Jacks: RJ48S
Service Order Code: 6.0N
Facility Interface Code: 04DU9.DN, 04DU9.BN, 04DU9.1KN, 04DU9.1SN
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact Polycom Inc in the U.S.A. 1-888-248-8294. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
Polycom, Inc. 7
Contents
New Hardware - RMX 1800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
New Hardware - MPMRx Media Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Front Panel & LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
NEW RTM LAN - with 4 LAN Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
RTM LAN - 4 LAN Ports LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
New Control (CNTL) Units for RMX 2000/4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
New Power Supply for RMX 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Version 8.3 - New Features List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Version 8.3 - Changes to Existing Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Version 8.3 - Interoperability Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Polycom Solution Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Collaboration Server (RMX) Web Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Windows 7™ Security Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Internet Explorer 8 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Version 8.3 - Upgrade Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Where to Get the Latest Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
RMX 1500/2000/4000 Software Upgrade Procedures . . . . . . . . . . . . . . . . . . . . . 32Upgrade Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Safe Upgrade Paths to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Preparing for the Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Doc Title in Header
Polycom, Inc. 8
Upgrading from Version 7.0 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Upgrading from Version 7.0 to Version 7.0.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Upgrade from Version 7.0.3 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Upgrading from Version 6.0.2 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Intermediate Upgrade from Version 6.0.2 to Version 7.0.3 . . . . . . . . . . . . . . . . . . . . . . . . 40
Upgrade from Version 7.0.3 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Upgrading from Versions 6.0/6.0.1 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Intermediate Upgrade from Version 6.0/6.0.1 to Version 6.0.2 . . . . . . . . . . . . . . . . . . . . . 41
Intermediate Upgrade from Version 6.0.2 to Version 7.0.3 . . . . . . . . . . . . . . . . . . . . . . . . 42
Upgrade from Version 7.0.3 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Upgrading from Version 5.0.2 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Intermediate Upgrade from Version 5.0.2 to Version 7.0.3 . . . . . . . . . . . . . . . . . . . . . . . . 43
Upgrade from Version 7.0.3 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Upgrading from Versions 5.0/5.0.1 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Intermediate Upgrade from Version 5.0/5.0.1 to Version 5.0.2 . . . . . . . . . . . . . . . . . . . . . 44
Intermediate Upgrade from Version 5.0.2 to Version 7.0.3 . . . . . . . . . . . . . . . . . . . . . . . . 44
Upgrade from Version 7.0.3 to Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Additional/Optional System Updates After Upgrading . . . . . . . . . . . . . . . . . . . . 46IVR Services Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Gathering Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SIP Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Media Encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Automatic Muting of Noisy AVC-based Endpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
RealPresence DMA system Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Upgrading the RMX Manager Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Upgrading the RMX 2000/4000 Hardware to MPMRx . . . . . . . . . . . . . . . . . . . . . . 53
Version 8.3 Detailed Description - New Features . . . . . . . . . . . . . . . . . . . . . . . . 54RMX 1800 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
RMX 1800 Feature Changes and Additions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Resource Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Hardware Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Initial Setup Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
RMX 1800 Name in the Banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Network Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Fast Configuration Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
New Features in Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
MPMRx Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Doc Title in Header
Polycom, Inc. 9
MPMRx Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
MPMRx Conferencing Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
MPMRx System Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Operating Mode Selection During Startup / Restart . . . . . . . . . . . . . . . . . . . . . . . . . . 67
MPMRx Resolutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Resolution Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
RMX 2000/ RMX 4000 MPMRx Resource Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
RMX 2000/ RMX 4000 Resource Capacities in Video Switching (VSW) Conferences 68
MPMRx Resource Capacities in Non-Mixed CP and SVC Conferences . . . . . . . . . . 69
MPMRx Resource Capacities in CP and SVC Mixed Conferences . . . . . . . . . . . . . . 70
Total Resource Capacities per MPMRx-D Card in CP & SVC Conferences . . . . . . . 71
Total Resource Capacities per MPMRx-S Card in CP & SVC Conferences . . . . . . . 72
System Information Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Switching to the MPMRx Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
New MPMRx Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MPMRx Hardware Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MPMRx Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
MPMRx Hardware Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
MPMRx Resource Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Port Gauge Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Video/Voice Port Configuration Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Gateway Calls to Remote SIP Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Calling a SIP Endpoint in a Remote Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Version 8.3 Detailed Description - Changes to Existing Features . . . . . . . . . . . 80HD1080p60 Symmetric Resolution Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Guidelines for Using HD1080p60 Video Resolution Symmetrically . . . . . . . . . . . . . . 80
Selecting HD1080p60 Symmetric Video Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . 81
HD1080p30 and HD1080p60 Content Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
HD1080p30 and HD1080p60 Content Support Guidelines . . . . . . . . . . . . . . . . . . . . . . . . 82
Sharing Base and High Profile Content with HD1080p30/60 Resolution . . . . . . . . . . . . . 82
Changes to the Video Quality Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
6Mbps Line Rate Supported on RealPresence Collaboration Server (RMX) 1800 . . . . . 89
Support of 6Mbps Line Rate in AVC-CP Conferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
General Guidelines for Using 6Mbps Line Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Doc Title in Header
Polycom, Inc. 10
Corrections and Known Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Corrections Between Version 8.2 and Version 8.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Version 8.3 Known Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Troubleshooting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Collaboration Server Web Client Installation - Troubleshooting Instructions . . . . . . . . . 118
Procedure 1: Ending all Internet Explorer Sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Procedure 2: Deleting the Temporary Internet Files, RMX Cookie and RMX Object . . . 120
Deleting the Temporary Internet Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Deleting the RMX/Collaboration Server Cookie . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Deleting the RMX/Collaboration Server ActiveX Object . . . . . . . . . . . . . . . . . . . . . . 124
Procedure 3: Managing Add-ons Collisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Procedure 4: Add the Collaboration Server to the Internet Explorer Trusted Sites List . 126
Procedure 5: Browser Hosting Controls (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
RMX Release Notes Version 8.3 New Hardware - RMX 1800
Polycom, Inc. 11
New Hardware - RMX 1800
The Polycom RealPresence Collaboration Server (RMX) 1800 system is the latest Multipoint Control Unit (MCU) in the RMX family. The RMX 1800 system is a high performance, scalable, IP-network (H.323 and Session Initiation Protocol [SIP]) MCU that provides feature-rich and easy-to-use multipoint voice and video conferencing.
RMX Release Notes Version 8.3 New Hardware - MPMRx Media Card
Polycom, Inc. 12
New Hardware - MPMRx Media Card
RMX Version 8.3 supports the latest MPMRx (Media Processing Module) card which increases the RMX’s capacity and capabilities.
The new MPMRx card (Media Processing Module) when installed in RMX running version 8.3 offers:
Increased resource capacity
New Symmetric HD1080p60 fps video resolution
Two types of MPMRx card with different port capacities are available:
MPMx-D (double mezzanine)
MPMx-S (single mezzanine)
For more information on MPMRX card capacities, see The MPMRx card is supported from version 8.3 and above. When this card is installed on any RMX 2000/4000 MCU, software version downgrades are not supported. Mixed modes with other MPM/MPM+/MPMx cards installed on the system are not supported.
MPMRx-D Card
MPMRx-S Card
When MPMRx card is installed, the RMX operates in MPMRx Mode giving the administrator enhanced control and monitoring of Resource Capacity and usage within the system.
Two upgrade kits are provided for the RMX platform:
RMX 2000 - VRMX2000RXUP: this kit includes a new power supply, new control (CNTL 2000) unit and two RTM LAN cards
MPMRx cards are supported only with software version 8.3 and above
RMX2000 systems requires chassis of the type D or E.
RMX2000 systems with MPMRx cards require a new power supply, new control (CNTL 2000) unit and two new RTM LAN cards.
RMX4000 systems with MPMRx cards are supported only with new control (CNTL 4000) unit.
RMX Release Notes Version 8.3 New Hardware - MPMRx Media Card
Polycom, Inc. 13
RMX 4000 - VRMX4000RXUP: this kit includes the new control (CNTL 4000) unit
The following table lists the changes in version 8.3 to support the new MPMRx card:
Front Panel & LEDs
In terms of Look and Feel and LED functionality, the MPMRx front panel is identical to that of the MPMx.
NEW RTM LAN - with 4 LAN PortsThe RTM LAN card routes data between the MPMRx cards and components of the system, and sends media by IP packets and provides connectivity to external IP networks.
The RTM LAN card with four 1 GB ports is required on the RMX 2000 when MPMRx cards are installed on the system. On RMX 4000 systems, RTM LAN cards with either two or four 1 GB ports can be used with the MPMRx card(s). However on systems with ISDN networks, the RTM ISDN can also be used instead of the RTM LAN.
An RTM LAN card must connect directly to an MPMx/MPMRx card. In an RMX with a single MPMx/MPMRx card, the RTM LAN card must be installed in the rear panel slot on the same level as the MPMx/MPMRx card.
On the RMX 2000/4000, LAN 2* is used to connect the LAN cable. For LAN Redundancy and Multiple Services connect to LAN 1*.
New ports on the RTM LAN card are:
Category Feature Name Description
General Card Configuration Mode A new Card Configuration Mode - MPMRx has been added to support the new media card.
General Hardware Monitor The status and properties of the MPMRx card can be viewed and monitored in the Hardware Monitor list pane.
General Video/Voice Port Configuration The Resource slider(s) in the Video/Voice Port Configuration dialog box reflect the MPMRx card capacities.
General Resource Report The resource report reflects the MPMRx card capacities.
General Port Gauges The Video Port gauge shows the MPMRx card capacities.
• An MPMRx card on the front of the RMX must always be seated or connected opposite to either an RTM LAN - 4 ports or RTM ISDN card on the rear of the chassis.
• The RTM LAN card is always required with Multiple Networks and LAN Redundancy configurations.
* MPMx cards are required connect to LAN 4. For LAN Redundancy and Multiple Services connect to LAN 3.
RMX Release Notes Version 8.3 New Hardware - MPMRx Media Card
Polycom, Inc. 14
1 Gb LAN ports No. 3-4, used with MPMx cards (*see note above).
DBG - Debug port, for internal use.
ARM/CM - Switch, for internal use.
RTM LAN - with 4 LAN Ports
RTM LAN - 4 LAN Ports LEDs
The following LEDs appear on the RTM LAN:
New Control (CNTL) Units for RMX 2000/4000 The Control (CNTL) Unit contains the management component and CPU of the RMX. When MPMRx-D card or cards are installed on the RMX 2000 and RMX 4000, each MCU requires a new control unit (CNTL). The CNTL unit manages the software and hardware on the system.New on the Control Unit is a VGA (video) port but this is for internal use only.
The two models are:
CNTL 2000
CNTL 4000
CNTL 2000
Function Name LED Name LED Color Description
LAN 1-4 LEDs 1 Gb Amber ON when 1Gb connection is online, flickers with Packet activity.
LNK Green ON with an active network connection, flickers with Packet activity.
HS LED Blue OFF - Normal.
Flashes - During the startup of a media card and control unit. Also flashes when the RTM LAN card is powered down.
ON - RTM LAN card may be removed.
RMX Release Notes Version 8.3 New Hardware - MPMRx Media Card
Polycom, Inc. 15
CNTL 4000
New Power Supply for RMX 2000The power supply provides electricity to the different components of the RMX 2000.The RMX 2000 system with MPMRx-D cards installed requires a new power supply with a higher power specification. The new power supply has a usage rating of: 4-8 AMPs, 1000 Watts and a BTU of 3412.14 per hour.
RMX Release Notes Version 8.3 Version 8.3 - New Features List
Polycom, Inc. 16
Version 8.3 - New Features List
The following table lists the new features in Version 8.3
.
# CategoryFeature Name Description
Card Mode
MPMx MPMRx
1 Conferencing Mute detection for Polycom SIP endpoints
From Version 8.3, when Polycom SIP endpoints mute themselves, the Mute icon is displayed in the Participants pane of the RMX Web Client/RMX Manager to indicate that they are muted.
2 Microsoft Gateway calls to remote SIP domain.
The RMX’s Gateway functionality can be used to enhance Polycom’s Microsoft Solution, enabling the connection of Legacy endpoints to connect to Lync 2010 endpoints.
3 Resources Resource Reporting
The unit used for reporting video resource usage in the Resource Report is HD720p30 CP. Results are rounded to the nearest integer. The MPM Rx does not support the Fixed Resource Capacity mode.
4 Resources Video/Voice Port Configuration
The Resource slider(s) in the Video/Voice Port Configuration dialog box reflect the MPMRx card capacities.
5 Video System Flag A new System Flag: LIMIT_SD_AND_CIF_BW_MPMRX, when added to system.cfg and set to YES (default), limits the maximum negotiated and opened bit rate for resolutions equal or lower than SD to 1Mbps.
When set to NO no limitation is applicable to SD and CIF bit rates.
RMX Release Notes Version 8.3 Version 8.3 - Changes to Existing Features
Polycom, Inc. 17
Version 8.3 - Changes to Existing Features
The following table lists the changes to existing features in Version 8.3.
Table 1 Version 8.3 - New Features List
# Category Feature Name
Description Card Mode
MPMx MPM Rx
Video HD1080p60 Symmetric
HD1080p60 Resolution is symmetric
Video HD1080p30/60 Content
Content is supported at resolutions of HD1080p30 and HD1080p60 in both Base and High Profiles.
An additional check box H.264 High Profile and an additional Content Rate drop-down menu have been added to the Video Quality dialog box.
POCN TIP Content Beginning with this version, TIP Content can be sent to Legacy Endpoints.
Conferencing Address Book
All users can now add or modify Address Book entries.
DTMF Codes System Flag RFC2833_DTMF System Flag, which controls receipt of in-band or out-of-band DTMF Codes can be accessed and modified by the user.
Video (RMX 1800)
6Mbps supported
The RealPresence Collaboration Server (RMX) 1800 supports AVC-CP conferences at a line rates up to and including 6Mbps.
General System Flag In Collaboration Server (RMX) 1500/2000/4000 systems with MPMx cards, the maximum number of PCM sessions is set by a system flag NUM_OF_PCM_IN_MPMX. The default value of this flag is set according to the SVC license:
• If SVC is enabled in the license the default value (and the only possible value is 1.
• If SVC is disabled in the license, the default value is 4 and the range is between 1 and 4.
To change this flag value you must first add it to the System Configuration.
(Not
required)
RMX Release Notes Version 8.3 Version 8.3 - Changes to Existing Features
Polycom, Inc. 18
General System Flag The support of External IVR Services via the MCCF-IVR package is enabled by default in the Collaboration Server (RMX) systems, by the flag ENABLE_MCCF which is set to YES.
However, in Ultra Secure Mode and in secured environments where the External IVR Services via the MCCF-IVR package is not required and unused ports should be closed, this flag should be set to NO.
To change this flag value from YES to No, you must first add it to the System Configuration.
Table 1 Version 8.3 - New Features List (continued)
# Category Feature Name
Description Card Mode
MPMx MPM Rx
RMX Release Notes Version 8.3 Version 8.3 - Interoperability Table
Polycom, Inc. 19
Version 8.3 - Interoperability Table
DevicesThe following table lists the devices tested with Version 8.3.
Device Version
Gatekeepers/Proxies
Polycom CMA Polycom CMA 6.2.5
Polycom RealPresence Resource Manager (XMA) Polycom XMA 8.0.1
Polycom PathNavigator 7.0.14
Polycom SE200 3.00.07
Polycom RMX Gateway 8.2
Cisco (Tandberg) VCS X7.2.2
Cisco (Tandberg) Gatekeeper N6.3
Microsoft Lync 2010 Server (Microsoft Lync 2010 Server is 4.0.7577.216 (CU8))
Microsoft Lync 2013 Server Microsoft Lync Server 2013- 5.0.8308.0
Broadsoft Proxy AS version Rel_19.sp1_1.574
Polycom RealPresence Access Director (RPAD 3.0
Recorder
Polycom RSS 4000 8.5.1.0-37259
MCUs, Call Managers, Network Devices, and Add Ins
Polycom RealPresence Distributed Media Application (DMA) system 7000
6.0.2.1, RMX 1800 requires version 6.0.3.
Polycom Conferencing Add in for Microsoft Outlook Polycom Conferencing for Outlook (PCO) 1.4.0
Avaya Aura Session Manager 6.3.0.8.5682-6.3.8.1814
Cisco Call Manager 9.1
Cisco (Tandberg) Codian 4505 MCU 4.4(3.49)
IBM WebSphere Application Server 7.0.0.15 (Network Deployment) plus required WebSphere iFixes.
RMX Release Notes Version 8.3 Version 8.3 - Interoperability Table
Polycom, Inc. 20
Siemens Server V7.00.01.ALL.07_PS0030.E06
Acme Packets SBC ACME Net-Net 3800 Firmware SCX6.4.0 MR-3 GA (Build 298)
Endpoints
Polycom HDX Family 3.1.2-35267
Polycom GS Family 4.1.1.1 Ursa
Polycom OTX 3.1.2-35267
Polycom RPX 3.1.2-35267
Polycom VSX and V-Series Family 9.0.6.2
Polycom Viewstation Family 7.5.4 or higher
Polycom Viewstation FX/EX/4000 6.0.5 or higher
Polycom CMA Desktop 5.2.x
Polycom CMA Desktop for MAC 5.2.3
Polycom QDX6000 4.0.3
Polycom RealPresence Mobile Android 3.0
Polycom RealPresence Mobile iPad 3.0
Polycom m100 1.0.6
Polycom VVX1500 4.0.4
Polycom VVX500 4.1.5
Polycom VVX600 4.1.5
SoundPointIP 650 4.0.4
Polycom Sound Point 601 SIP 3.1.7
Polycom PVX 8.0.16
Polycom SoundStation IP4000 SIP 3.1.7
Polycom SoundStation IP7000 4.0.4
Polycom HDX Touch Controller 1.8
Polycom Group Series Touch Controller 4.1.1.1
Avaya Voice Phone S3.171b
Avaya one-X Communicator 6.1.8.06-SP8-40314
Avaya 1000 series endpoint 4.8.3
Avaya Flare Desktop 1.1.3.14
Device Version
RMX Release Notes Version 8.3 Version 8.3 - Interoperability Table
Polycom, Inc. 21
Avaya ADVD 1_1_2_020002
Avaya Flare Mobile (iOS) 1.1.1.0
LifeSize 200 4.7.22(3)
LifeSize Room and Express 4.7.22(3)
LifeSize Desktop Client 2.0.2.191
LifeSize Express 220 4.11.13(1)
LifeSize Team 220 4.11.13(1)
LifeSize Passport 4.11.13(1)
LifeSize SoftPhone 8.1.12
Cisco (Tandberg) EX90 6.2
Cisco (Tandberg) C Series 6.2
Cisco (Tandberg) MXP F-series F9.3.1
Cisco E20 4.1.2
Cisco CTS3010 (Telepresence) 1.10.1
Cisco CTS1300 (Telepresence) 1.10.1
Cisco CTS500 (Telepresence) 6.0.2
Radvision SCOPIA XT1000 endpoint 2.5.416
Radvision Scopia XT5000 3.1.1.37
Sony PCS –1 3.42
Sony PCS –G50 2.72
Sony PCS –TL50 2.42
Sony PCS-G90 2.22
Sony PCS-XG80 2.37
Tandberg 1700 MXP F9.3.1
Tandberg Edge95 MXP F9.3.1
CSS Server 1.1.1
Addon client 1.1.1
Microsoft Lync 2013 client Lync 2013 client 15.0.4517.1504
Microsoft Lync 2010 client Lync 2010 client 4.0.7577.4392)
Siemens Client V7R1.17.0
Device Version
RMX Release Notes Version 8.3 Version 8.3 - Interoperability Table
Polycom, Inc. 22
Siemens OpenStage Desktop Voice V3R1 43
IBM DB2 Database Server 9.7
IBM Domino® Enterprise Server V8.5.2
IBM Notes client V8.5.2
IBM Sametime Media Manager V8.5.2 IFR 1
IBM Sametime System Console V8.5.2 IFR 1
IBM Sametime Community Server V8.5.2 IFR 1
IBM Sametime Proxy Server V8.5.2 IFR 1
IBM Sametime Meeting Server V8.5.2 IFR 1
For more information about partner product interoperability, refer to the partner deployment guides.
Device Version
RMX Release Notes Version 8.3 Polycom Solution Support
Polycom, Inc. 23
Polycom Solution Support
Polycom Implementation and Maintenance services provide support for Polycom solution components only. Additional services for supported third-party Unified Communications (UC) environments integrated with Polycom solutions are available from Polycom Global Services and its certified Partners. These additional services will help customers successfully design, deploy, optimize and manage Polycom visual communications within their UC environments.
Professional Services for Microsoft Integration is mandatory for Polycom Conferencing for Microsoft Outlook and Microsoft Office Communications Server integrations. For additional information and details please see http://www.polycom.com/services/professional_services/index.html or contact your local Polycom representative.
RMX Release Notes Version 8.3 Collaboration Server (RMX) Web Client
Polycom, Inc. 24
Collaboration Server (RMX) Web Client
The following table lists the environments (Web Browsers and Operating Systems) with which the Collaboration Server (RMX) Web Client was tested.
Web Browser Operating System
Internet Explorer 7 Windows Vista™
Windows 7
Internet Explorer 8 Windows 7
Internet Explorer 9 Windows 7 and Windows 8
Internet Explorer 10 Windows 8
It is not recommended to run RMX Web Client and Polycom CMAD applications simultaneously on the same workstation.
RMX Release Notes Version 8.3 Windows 7™ Security Settings
Polycom, Inc. 25
Windows 7™ Security Settings
If Windows 7 is installed on the workstation, Protected Mode must be disabled before downloading the software to the workstation.
To disable Protected Mode:
1 In the Internet Options dialog box, click the Security tab.
The Security tab is displayed.
2 Clear the Enable Protected Mode check box for each of the following tabs:
Internet
Local intranet
Trusted sites
RMX Release Notes Version 8.3 Windows 7™ Security Settings
Polycom, Inc. 26
3 After successful connection to Collaboration Server (RMX), the Enable Protected Mode check boxes can be selected to enable Protected Mode for the following tabs:
Internet
Local intranet
RMX Release Notes Version 8.3 Internet Explorer 8 Configuration
Polycom, Inc. 27
Internet Explorer 8 Configuration
When using Internet Explorer 8 to run the Collaboration Server Web Client or RMX Manager applications, it is important to configure the browser according to the following procedure.
To configure Internet Explorer 8:
1 Close all browsers running on the workstation.
2 Use the Windows Task Manager to verify that no iexplore.exe processes are running on the workstation. If any processes are found, use the End Task button to end them.
3 Open Internet Explorer but do not connect to the MCU.
4 In the Internet Explorer menu bar select Tools >> Internet Options.
The Internet Options dialog box is displayed with General tab open.
5 In the Browsing history section, click the Delete button.
The Delete Browsing History dialog box is displayed.
RMX Release Notes Version 8.3 Internet Explorer 8 Configuration
Polycom, Inc. 28
6 Select the Temporary Internet files and Cookies check boxes.
7 Click the Delete button.
8 The Delete Browsing History dialog box closes and the files are deleted.
9 In the Internet Options dialog box, click the Settings button.
The Temporary Internet Files and History Settings dialog box is displayed.
10 Click the View objects button.
The Downloaded Program Files folder containing the installed Program Files is displayed.
RMX Release Notes Version 8.3 Internet Explorer 8 Configuration
Polycom, Inc. 29
11 Select the EMAClassLoader.dll file and press the Delete key on the workstation or right-click the EMA.ClassLoader.dll file and then click Delete.
12 Close the Downloaded Program Files folder and the Temporary Internet Files and History Settings dialog box.
13 In the Internet Options dialog box, click the OK button to save the changes and close the dialog box.
RMX Release Notes Version 8.3 Version 8.3 - Upgrade Package Contents
Polycom, Inc. 30
Version 8.3 - Upgrade Package Contents
The Version 8.3 upgrade package must be downloaded from the Polycom Resource Center and includes the following items:
lan.cfg file
LanConfigUtility.exe
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Documentation
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Version 8.3 Release Notes
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Hardware Guide
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Quick Installation Booklet
Installation Quick Start Guide for RealPresence Collaboration Server (RMX) 1500/1800/2000/4000
RMX Third Party Licenses
External DB Tools
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 External Database API Programmer’s Guide
Sample Scripts
RMX XML API Kit Version 8.3
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 XML API Version 8.3 Release Notes
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 API Overview
RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 API Schema Reference Guide
MGC to RMX XML API Conferencing Comparison
Polycom XML Tracer User’s Guide
XML Schemas
Polycom XML Tracer application
Translations of RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Version 8.1 Documentation:
Getting Started Guide:
French, German, Japanese, Russian, Simplified Chinese, Hebrew and Portuguese
Hardware Guide:
French, German, Japanese, Korean, Russian, Simplified Chinese, Spanish
RMX Release Notes Version 8.3 Version 8.3 - Upgrade Package Contents
Polycom, Inc. 31
Where to Get the Latest Product Information
To view the latest Polycom product documentation, visit the DOCUMENTS & DOWNLOADS section of the Polycom website at http://support.polycom.com
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 32
RMX 1500/2000/4000 Software Upgrade Procedures
Upgrade Guidelines Ensure that the Control Unit memory size is at least 1024MB. If memory size is 512MB, DO NOT
perform the upgrade procedure. Contact Polycom Support.
To upgrade to 8.3 with the new MPMRx card, perform the following procedures:
1 Upgrade the MCU to software version 8.3 following the specific upgrade procedures for your current version.
2 If the MCU contains MPM or MPM+ cards, make sure that these cards are disabled.
3 Remove the existing cards from the MCU and insert the MPMRx card.
4 In the Hardware Monitor screen, click the reset button to reset the MCU.
5 If required, perform the following additional steps:
IVR Service Update. For more information, see IVR Services Update .
Gathering Settings. For more information, see Gathering Settings .
SIP Registration. For more information, see SIP Registration .
Media Encryption. For more information, see Media Encryption .
Noise Reduction. For more information, see Automatic Muting of Noisy AVC-based Endpoints .
RealPresence DMA System Capabilities. For more information, see RealPresence DMA system Compatibility .
To check the MCU’s memory size:
» In the RMX Web Client/RMX Manager go to Administration > System Information.
• Version 8.3 does not support MPM or MPM+ cards. DO NOT upgrade to Version 8.3 if MPM or /MPM+ cards are installed in the RMX and contact Polycom Support.
• If the upgrade process includes upgrading the Media cards, refer to the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 MPMx Migration Procedure documentation.
• Its is recommend you use Backup Configuration function prior to upgrading your MCU. For more information see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator's Guide, Software Management.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 33
If Windows7™ is installed on the workstation, Protected Mode must be disabled before downloading the RMX software to the workstation. For more information see Windows 7™ Security Settings .
To maximize conferencing performance, especially in high bit rate call environments, a 1 Gb connection is recommended for each LAN connection.
If the default POLYCOM user is defined in the Collaboration Server Web Client, an Active Alarm is created and the MCU status changes to MAJOR until a new Administrator user replaces the default user.
To use the new features such as Exit and Entry Tones the IVR Services must be updated. For more details, see Additional/Optional System Updates After Upgrading .
If upgrading from a version that does not include Gathering Phase, to enable it in the existing Profiles you must modify the Profiles assigned to the conferencing entities. For more details, see Gathering Settings .
To keep the conferencing entities registered with the SIP Server defined in the IP Network Service, registration must be enabled in the Profiles assigned to these entities. For more details, see SIP Registration .
If upgrading from a version that does not include the Auto Mute noisy participants option, to enable it in the existing Profiles you must modify the Profiles assigned to the conferencing entities. For more details, see Automatic Muting of Noisy AVC-based Endpoints .
Safe Upgrade Paths to Version 8.3The RMX includes a safety mechanism to ensure that a viable and safe software version installation is selected on an RMX. It ensures that the current RMX software version and the new software installation are matched to an internal logic table, and enables or rejects the software installation. When an incorrect or non-viable version upgrade/downgrade path is attempted, an alarm and fault are activated on the RMX.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 34
The following table lists the software versions that are approved for upgrade by Safe Upgrade process for version 8.3.
If your RMX version is not listed above, refer to the table below for intermediate and safe upgrade paths to version 8.3.
Software Version RMX 1500X RMX 1500Q RMX 1800RMX 2000
MPMxRMX 4000
MPMx
8.2
8.1.8
8.1.5
8.1
7.8
7.7
7.6/7.6.1
7.5.0J/7.5.1J
7.2/7.2.x
7.1
7.0.x/7.0.2C
7.0
6.x
5.x
4.7.2
If you are upgrading from version 2.x, 3.x or 4.x, DO NOT upgrade to Version 8.3 and contact Polycom Support for the appropriate upgrade paths.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 35
You can disable the safety upgrade mechanism by changing the default setting of the ENFORCE_SAFE_UPGRADE system flag to NO.
Preparing for the Upgrade
To prepare for the upgrade:
1 If the RMX is used with a RealPresence DMA system, disable the RealPresence DMA system functionality:
a Log into the DMA that handles call transfers for the RMX.
b Select Network > MCU > MCUs.
c Select the MCU and choose either Stop Using or Busy Out.
2 Verify that all conferences, including permanent conferences, have been terminated.
3 If upgrading from 7.0.1 or higher:
Current Version
First Intermediate Upgrade
Second Intermediate Upgrade
Third Intermediate Upgrade New Version
Version Key Version Key Version Key Version Key
8.2 N/A N/A N/A 8.2 Yes
8.1 N/A N/A N/A 8.2 Yes
7.8 N/A N/A N/A 8.2 Yes
7.7 N/A N/A N/A 8.2 Yes
7.6/7.6.1 N/A N/A N/A 8.2 Yes
7.5.0J/7.5.1J N/A N/A N/A 8.2 Yes
7.2 / 7.2.1 / 7.2.2 N/A N/A N/A 8.2 Yes
7.0.1 / 7.0.2 / 7.0.3 / 7.1
N/A N/A N/A 8.2 Yes
7.0 7.0.3 No N/A N/A 8.2 Yes
6.0.2 7.0.3 Yes N/A N/A 8.2 Yes
6.0 / 6.0.1 6.0.2 No 7.0.3 Yes N/A 8.2 Yes
5.0.2 7.0.3 Yes N/A N/A 8.2 Yes
5.0 / 5.0.1 5.0.2 No 7.0.3 Yes N/A 8.2 Yes
• After the upgrade is complete, all permanent conferences must be manually rescheduled.
• MPMx cards are not supported from version 8.1
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 36
a Download the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide.
4 If upgrading from 7.0:
a Download the Version 7.0.3 software and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Obtaining the Activation Key.
5 If upgrading from 5.0.2 or 6.0.2:
a Download the Version 7.0.3 software and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 7.0.3 Product Activation Key and the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Obtaining the Activation Key.
6 If upgrading from 6.0 or 6.0.1:
a Download the Version 6.0.2 software, the Version 7.0.3 software, and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 7.0.3 Product Activation Key and the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Obtaining the Activation Key.
7 If upgrading from 5.0 or 5.0.1:
a Download the Version 5.0.2 software, the Version 7.0.3 software, and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 7.0.3 Product Activation Key and the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Obtaining the Activation Key.
8 If upgrading from 4.x:
a Download the Version 5.0.2 software, the Version 7.0.3 software, and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 5.0.2 Product Activation Key, the Version 7.03 Product Activation Key, and the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide Obtaining the Activation Key.
9 If upgrading from 2.x or 3.x:
a Download the Version 4.1.1 software, the Version 5.0.2 software, the Version 7.0.3 software, and the Version 8.3 software from the Polycom Resource Center web site.
b Obtain the Version 4.1.1 software, the Version 7.0.3 Product Activation Key and the Version 8.3 Product Activation Key from the Polycom Resource Center web site. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Obtaining the Activation Key.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 37
10 Backup the configuration file. For more information, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide, Software Management.
Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3
1 Install MCU Software Version 8.3. On the RMX menu, click Administration> Software Management > Software Download.
2 Browse to the Install Path, selecting the Version 8.3.x.x.bin file in the folder where Version 8.3 is saved and click Install.
3 The Install Software information box that the file Copying files is In progress.
At the end of the Copying Files process the system displays an indication that the software copying procedure is Done.
When an incorrect or non viable version upgrade/downgrade is attempted, an alarm and fault are activated on the RMX.
Click OK. The RMX software installation procedure is aborted and a system alert activates in the Faults List as shown below.
During any upgrade or downgrade software version installation when the Safe Software Version Installation warning has been activated your current browser session will block any new installation attempt. This applies to all software versions, except for version 7.6 which will still enable version downgrades. As a workaround close and then re-open a new browser session, which will enable you to start a new software version installation.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 38
4 Click the OK button.
The Install Software information box indicates that Software Loading is in progress.
A series of Active Alarms are displayed indicating the progress of the upgrade process.
The Install Software information box indicates that IPMC Burning is in progress.
A further series of Active Alarms are displayed indicating the progress of the upgrade process.
The upgrade procedure takes approximately 20 minutes.
A system message alert may be displayed, if so then click Next/Cancel.
Sometimes, when updating the Version 8.3 license key, the system displays the active alarm show below:
Ignore this Active Alarm and complete this installation procedure.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 39
Connection to the RMX is terminated and you are prompted to reopen the browser.
5 Approximately 10 minutes after receiving this message, close and reopen the browser.
6 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
If the browser displays a message indicating that it cannot display the requested page, close and reopen the browser and connect to the RMX.
The version number in the Welcome screen has changed to 8.3.
7 In the Collaboration Server Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
To use the new features such as Operator Assistance and Gateway Sessions the IVR Services must be updated. For more details, see Additional/Optional System Updates After Upgrading .
8 If the Collaboration Server (RMX) is used with a RealPresence DMA system, enable the RealPresence DMA system functionality:
9 Log into the RealPresence DMA system that handles call transfers for the Collaboration Server (RMX).
10 Select Network > MCU > MCUs.
11 Select the MCU and choose Start Using.
12 Verify that the version number is updated signifying that the upgrade is complete.
Upgrading from Version 7.0 to Version 8.3This upgrade requires an intermediate upgrade from Version 7.0 to Version 7.0.3.
Upgrading from Version 7.0 to Version 7.0.31 Install MCU Software Version 7.0.3.
On the RMX menu, click Administration> Software Management > Software Download.
If the error “Browser environment error. Please close all the browser sessions” appears, close all the browser sessions, and reconnect to the RMX. If the error message appears again, either run the automatic troubleshooter utility or manually preform the suggested troubleshooting procedures. For more details, see Troubleshooting Instructions .
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 40
2 Browse to the Install Path, selecting the Version 7.0.3.x.bin file in the folder where Version 7.0.3 is saved and click Install.
The Install Software information box indicates that Copying Files is In progress.
The Install Software information box indicates that Software Loading is In progress.
A series of Active Alarms are displayed indicating the progress of the upgrade process.
The Install Software information box indicates that IPMC Burning is In progress.
A further series of Active Alarms are displayed indicating the progress of the upgrade process.
The upgrade procedure takes approximately 20 minutes.
Connection to the RMX is terminated and you are prompted to reopen the browser.
3 Approximately 5 minutes after receiving this message, close and reopen the browser.
4 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
If the browser displays a message indicating that it cannot display the requested page close and re-open the browser and connect to the RMX.
The version number in the Welcome screen has changed to 7.0.3.
5 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
Upgrade from Version 7.0.3 to Version 8.3
» Continue with the upgrade from 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1 / 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7 /7.8 to Version 7.8 as described on Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 .
Upgrading from Version 6.0.2 to Version 8.3This upgrade requires an intermediate upgrade from Version 6.0.2 to Version 7.0.3.
Intermediate Upgrade from Version 6.0.2 to Version 7.0.3
1 Install MCU Software Version 7.0.3. On the RMX menu, click Administration > Software Management > Software Download.
2 Browse to the Install Path, selecting the Version 7.0.3.x.bin file in the folder where Version 7.0.3 is saved and click Install.
The Install Software information box that Copying Files is In progress.
At the end of the installation process the system displays an indication that the software copying procedure is Completed and that a new Activation Key is required.
3 Click the OK button.
4 On the RMX menu, click Setup > Product Activation.
The Product Activation dialog box is displayed with the Serial Number field completed.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 41
5 In the Activation Key field, enter or paste the Product Activation Key obtained earlier and click the OK button.
At the end of the Product Activation process the system displays an indication that the Product Activation Key was successfully installed.
6 Click the OK button.
The Install Software information box indicates that Software Loading is In progress.
A series of Active Alarms are displayed indicating the progress of the upgrade process.
The Install Software information box indicates that IPMC Burning is In progress.
A further series of Active Alarms are displayed indicating the progress of the upgrade process.
After about 30 minutes, close and reopen the browser and connect to the RMX. If the browser was not closed and reopened, the following error message is displayed: Browser environment error. Please reopen the browser. If this occurs, close and re-open the browser and connect to the RMX.
The version number in the Welcome screen has changed to 7.0.3.
7 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
Upgrade from Version 7.0.3 to Version 8.3
» Continue with the upgrade from 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1 / 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7 /7.8/8.1 to Version 8.3 as described on Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 .
Upgrading from Versions 6.0/6.0.1 to Version 8.3This upgrade requires the following intermediate upgrade procedures:
1 Upgrade from Version 6.0./6.0.1 to Version 6.0.2.
2 Upgrade from Version 6.0.2 to Version 7.0.3.
Intermediate Upgrade from Version 6.0/6.0.1 to Version 6.0.2
1 Install MCU Software Version 6.0.2. On the RMX menu, click Administration > Software Management > Software Download.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 42
2 Browse to the Install Path, selecting the Version 6.0.2.x.bin file in the folder where Version 6.0.2 is saved and click Install.
The Install Software information box indicatesthat Copying Files is In progress.
The Install Software information box indicates that Software Loading is In progress.
A series of Active Alarms are displayed indicating the progress of the upgrade process.
The Install Software information box indicates that IPMC Burning is In progress.
A further series of Active Alarms are displayed indicating the progress of the upgrade process.
The upgrade procedure takes approximately 20 minutes.
Connection to the RMX is terminated and you are prompted to reopen the browser.
3 After approximately 5 minutes close and reopen the browser.
4 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
If the browser displays a message indicating that it cannot display the requested page close and re-open the browser and connect to the RMX.
The Login screen is displayed. The version number has changed to 6.0.2.
5 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
Intermediate Upgrade from Version 6.0.2 to Version 7.0.3
» Continue with the upgrade from Version 6.0.2 to Version 7.0.3 as described starting on Intermediate Upgrade from Version 6.0.2 to Version 7.0.3 .
When upgrading from version 6.0.1, if after 20 minutes the system remains in the Loading Software stage:
and sometimes the following Active Alarm is displayed:
Close the Install Software window, access the Hardware Monitor and Reset the RMX.
After reset, the upgrade process continues as described below.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 43
Upgrade from Version 7.0.3 to Version 8.3
» Continue with the upgrade from 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1 / 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8 to Version 8.3 as described on Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 .
Upgrading from Version 5.0.2 to Version 8.3This upgrade requires an intermediate upgrade from Version 5.0.2 to Version 7.0.3.
Intermediate Upgrade from Version 5.0.2 to Version 7.0.3
1 Install MCU Software Version 7.0.3. On the RMX menu, click Administration > Software Management > Software Download.
2 Browse to the Install Path, selecting the Version 7.0.3.x.bin file in the folder where Version 7.0.3. is saved and click Install.
At the end of the installation process the Install Software dialog box indicates that the installed software is being checked. The system then displays an indication that the software was successfully downloaded and that a new activation key is required.
3 On the RMX 2000/4000 menu, click Setup > Product Activation.
The Product Activation dialog box is displayed with the Serial Number field completed.
4 In the Activation Key field, enter or paste the Product Activation Key obtained earlier and click the OK button.
At the end of the Product Activation process the system displays an indication that the Product Activation Key was successfully installed.
5 When prompted whether to reset the RMX, click Yes to reset the RMX
6 When prompted to wait while the RMX resets, click OK.
The upgrade procedure takes approximately 30 minutes.
Connection to the RMX is terminated and you are prompted to reopen the browser.
7 After approximately 30 minutes close and reopen the browser.
8 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
If the browser displays a message indicating that it cannot display the requested page, refresh the browser periodically until connection to the RMX is established and the Login screen is displayed.
You may receive a message stating Browser environment error. Please reopen the browser. If this occurs, close and re-open the browser and connect to the RMX.
9 Optional. Close and reopen the browser.
10 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
The Login screen is displayed. The version number has changed to 7.0.3.
11 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 44
Upgrade from Version 7.0.3 to Version 8.3
» Continue with the upgrade from 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1 / 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 as described on Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 .
Upgrading from Versions 5.0/5.0.1 to Version 8.3
This upgrade requires the following intermediate upgrade procedures:
1 Upgrade from Version 5.0./5.0.1 to Version 5.0.2.
2 Upgrade from Version 5.0.2 to Version 7.0.3.
Intermediate Upgrade from Version 5.0/5.0.1 to Version 5.0.2
1 Install MCU Software Version 5.0.2. On the RMX menu, click Administration> Software Management > Software Download.
2 Browse to the Install Path, selecting the Version 5.0.2.x.bin file in the folder where Version 5.0.2 is saved and click Install.
At the end of the installation process the system displays an indication that the software was successfully downloaded and that a new activation key is required.
3 Click Close to close the Install Software dialog box.
4 When prompted whether to reset the MCU, click Yes to reset the MCU.
At the end of the installation process the system displays an indication that the software was successfully downloaded.
The upgrade procedure takes about 30 minutes during which time an Active Alarm - System Upgrade is displayed.
The RMX resets itself during the upgrade process and connection to the RMX Web Client may be lost. If the workstation is logged in to the RMX Web Client during the resets, the MCU State indicator at the bottom right corner of the RMX Web Client screen indicates STARTUP.
5 After about 30 minutes, close and reopen the browser and connect to the RMX. If the browser was not closed and reopened, the following error message is displayed: Browser environment error. Please reopen the browser.
The version number in the Welcome screen has changed to 5.0.2.
6 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
Intermediate Upgrade from Version 5.0.2 to Version 7.0.3
1 Install MCU Software Version 7.0.3. On the RMX menu, click Administration > Software Management > Software Download.
2 Browse to the Install Path, selecting the Version 7.0.3.x.bin file in the folder where Version 7.0.3. is saved and click Install.
At the end of the installation process the Install Software dialog box indicates that the installed software is being checked. The system then displays an indication that the software was successfully downloaded and that a new activation key is required.
RMX Release Notes Version 8.3 RMX 1500/2000/4000 Software Upgrade Procedures
Polycom, Inc. 45
3 On the RMX 2000/4000 menu, click Setup > Product Activation.
The Product Activation dialog box is displayed with the Serial Number field completed.
4 In the Activation Key field, enter or paste the Product Activation Key obtained earlier and click the OK button.
At the end of the Product Activation process the system displays an indication that the Product Activation Key was successfully installed.
5 When prompted whether to reset the RMX, click Yes to reset the RMX..
6 When prompted to wait while the RMX resets, click OK.
The upgrade procedure takes approximately 30 minutes.
Connection to the RMX is terminated and you are prompted to reopen the browser.
7 After approximately 30 minutes close and reopen the browser.
8 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
The browser displays a message indicating that it cannot display the requested page.
9 Refresh the browser periodically until connection to the RMX is established and the Login screen is displayed.
You may receive a message stating Browser environment error. Please reopen the browser.
10 Optional. Close and reopen the browser.
11 Enter the IP address of the RMX Control Unit in the browser’s address line and press Enter to reconnect to RMX.
The Login screen is displayed. The version number has changed to 7.0.3.
12 In the RMX Web Client – Welcome screen, enter your User Name and Password and click Login.
In the Main Screen an MCU State indicator displays a progress indicator showing the time remaining until the system start-up is complete.
Upgrade from Version 7.0.3 to Version 8.3
» Continue with the upgrade from 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1 / 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 as described on Upgrading from Version 7.0.1 / 7.0.2 / 7.0.3 / 7.1 / 7.2 / 7.2.1/ 7.2.2 / 7.5.0J/7.5.1J/7.6/7.6.1/7.7/7.8/8.1 to Version 8.3 .
Sometimes when upgrading from version 5.0.2 to version 7.0.x the reset process fails. In such a case, you can try to connect to the MCU via the Shelf Management and reset the MCU from the Hardware Monitor or you can “hard” reset the MCU by turning the Power off and on again.
RMX Release Notes Version 8.3 Additional/Optional System Updates After Upgrading
Polycom, Inc. 46
Additional/Optional System Updates After Upgrading
IVR Services UpdateWhen upgrading from version 4.0 and earlier, Operator Assistance and the Gateway calls options require that the IVR Services include specific (new) DTMF Codes and voice messages. These additions are not automatically added to existing IVR Services in order to avoid conflicts with existing DTMF codes. Therefore, to use these options, new Conference and Entry Queue IVR Services must be created.
In Version 6.0, recording can be controlled from the HDX remote control using the designated recording buttons. This is enabled by changing the existing definitions of the DTMF codes of the Roll Call and Recording actions in the Conference IVR Services already defined in the RMX.
In Version 7.x, PCM for ISDN participants is enabled by a DTMF code. The code must be added to the DTMF Codes tab to enable the PCM for ISDN participants. Default value is 1.
In Version 7.6.1, a participant can invite another participant to the conference using a DTMF code. This code must be added manually to the existing Conference IVR Services. In addition, the Invite Participant voice message requesting the participant to enter the destination number must be selected in the General tab.
To modify the Conference IVR Service:
1 In the IVR Services list, double-click the service to modify or right click the service and select Properties.
2 To add the gateway voice messages and dial tones, click the General tab and select the appropriate *.wav files.
3 To modify the DTMF codes, click the DTMF Codes tab.
4 Modify the DTMF codes as follows:
Action Existing DTMF Code New DTMF Code
Enable Roll Call *32 *42
Disable Roll Call #32 #42
Roll Call Review Names *33 *43
Roll Call Stop Review #33 #43
Start/Resume Recording *73 *2
Stop Recording *74 *3
Pause Recording *75 *1
Request Private Assistance *0
RMX Release Notes Version 8.3 Additional/Optional System Updates After Upgrading
Polycom, Inc. 47
5 To add the Operator Assistance Options, click the Operator Assistance tab and select the appropriate options and messages.
For details on modifying the IVR Services, see RMX 2000 Administrator’s Guide, Defining a New Service.
Gathering SettingsWhen upgrading from earlier versions, the Enable Gathering check box in the Profile Properties - Gathering Settings dialog box is not selected by default for existing Profiles.
To set Enable Gathering as default:
1 In the RMX Management pane, click Conference Profiles.
2 In the Conference Profiles pane, double-click the Profile or right-click the Profile, and then click Profile Properties.
The Profile Properties – General dialog box opens.
3 Click Gathering Settings.
4 Select the Enable Gathering check box.
5 Click the OK Button.
For more information, see the RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide, Gathering Phase.
Request Assistance for the conference 00
PCM (for ISDN participants only) ##
Invite Participant *72
Disconnect Last Invited Participant #72
Action Existing DTMF Code New DTMF Code
RMX Release Notes Version 8.3 Additional/Optional System Updates After Upgrading
Polycom, Inc. 48
SIP RegistrationStarting with Version 7.1, enabling the registration of the conferencing entities with the SIP proxy is moved from the IP Network Service to the Conference Profile - Network Services. To ensure that conferencing entities that were registered with the SIP Server remain registered after upgrading to Version 8.3, the appropriate conference Profile must be updated accordingly.
To enable the registration with the SIP Server:
1 Verify which Profile is used by conferencing entities you wish to register with the SIP Server.
2 List the Conference Profiles.
3 Display the Profile Properties by double-clicking it or right-clicking the Profile and then selecting Properties.The Profile Properties - General dialog box opens.
4 Click the Network Services tab.
The Profile - Network Services dialog box is displayed.
The system lists the IP Network Services currently defined in the RMX depending on the system configuration (single Network or Multiple Networks).
5 In the SIP Registration column, click the check box of the Network Service to enable the registration of the conferencing entity to which this profile is assigned with the SIP Server defined in that Network Service.
6 To prevent dial in participants from connecting to a conferencing entity when connecting via a certain Network Service, clear the Accept Calls check box of that Network Service.
7 Click OK.
RMX Release Notes Version 8.3 Additional/Optional System Updates After Upgrading
Polycom, Inc. 49
Media EncryptionWhen upgrading from a version prior to 7.6.1, the ALLOW_NON_ENCRYPT_PARTY_IN_ENCRYPT_CONF System Flag is replaced by a value in the Conference Profile. Therefore, it is essential that the encryption settings of all existing conference Profiles are verified, and if necessary, modified to meet the encryption requirements through the new encryption options according to the table below.
Automatic Muting of Noisy AVC-based EndpointsWhen upgrading from a previous version, the Auto mute noisy endpoints option is not automatically enabled in the existing Profiles and it has to be manually enabled, if required.In new Profiles that are created after the upgrade, the Auto mute noisy endpoints option is automatically enabled.
To enable the automatic muting of noisy endpoints in existing Conference Profiles:
1 Double-click an existing Conference Profile to display its properties.
2 Click the Audio Settings tab.
Encryption Setting
Versions prior to 7.6.1 Version 7.6.1 and Later
Parameter Value Parameter Value
Profile Encryption Setting
YES Profile Encryption Setting Encrypt All
Profile Encryption Setting
NO Profile Encryption Setting No Encryption
System Flag ALLOW_NON_ENCRYPT_PARTY_IN_ENCRYPT_CONF=YES
Profile Encryption Setting Encrypt when possible
RMX Release Notes Version 8.3 Additional/Optional System Updates After Upgrading
Polycom, Inc. 50
In existing profiles (after software upgrade from a version prior to 8.3), the Auto mute noisy endpoints check box is cleared.
3 Click the Auto mute noisy endpoints check box to enable the automatic muting of noisy endpoints.
4 Click OK.
RealPresence DMA system Compatibility In Version 7.7, if a Polycom RealPresence DMA system is installed in your environment, you must change the value of the flag MAX_CONF_PASSWORD_REPEATED_CHAR to 4 to maintain the compatibility between the RMX and the RealPresence DMA system.
For more details, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide, Modifying System Flags.
RMX Release Notes Version 8.3 Upgrading the RMX Manager Application
Polycom, Inc. 51
Upgrading the RMX Manager Application
The RMX Manager application can be downloaded from one of the RMX systems installed in your site or from Polycom web site at http://www.polycom.com/support.
To install RMX Manager (downloading the application from the MCU):
1 Start Internet Explorer and connect to the Collaboration Server (RMX) from which the current RMX Manager version was installed.
The Login screen is displayed.
2 Click the Install RMX Manager link on the upper right corner of the Login screen.
The installer verifies the application’s requirements on the workstation.
• When upgrading the RMX Manager application, it is recommended to backup the MCU list using the Export RMX Manager Configuration option. For more details, see RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide, Software Management .
• When upgrading the RMX Manager from a major version (for example, version 7.0) to a maintenance version of that version (for example, 7.x), the installation must be performed from the same MCU (IP address) from which the major version (for example, version 7.0) was installed. If you are upgrading from another MCU (different IP address), you must first uninstall the RMX Manager application using Control Panel > Add or Remove Programs.
If the following error message is displayed, you are upgrading from an MCU that is other than the one used for the installed version (different IP address). In such a case, first uninstall the RMX Manager application using Control Panel > Add or Remove Programs.
RMX Release Notes Version 8.3 Upgrading the RMX Manager Application
Polycom, Inc. 52
The Install dialog box is displayed.
3 Click the Install button.
The installation proceeds.
The installation completes, the application loads and the RMX Manager - MCUs screen is displayed.
The list includes the previously defined MCUs.
If the MCUs list is empty, import the backed up list using the Import RMX Manager Configuration option. For more details, see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide Import/Export RMX Manager Configuration .
MCUs Pane
MCUs Toolbar
RMX Release Notes Version 8.3 Upgrading the RMX 2000/4000 Hardware to MPMRx
Polycom, Inc. 53
Upgrading the RMX 2000/4000 Hardware to MPMRx
Two upgrade kits are provided for the RMX platform:
RMX 2000 - VRMX2000RXUP:
CNTL unit
Power Module
2 RTM LAN cards
at least one MPMRx-D/MPMRx-S card
Software Activation Key, for the latest RMX software version
Version 8.3 Documentation
RMX 4000 - VRMX4000RXUP:
CNTL unit
at least one MPMRx-D/ MPMRx-S card
Software Activation Key, for the latest RMX software version
Version 8.3 Documentation
Upgrading the RMX with MPMRx cards involves the following processes:
Process 1: Removing RMX Hardware
Process 2: Installing RMX Hardware
Process 3: Software Upgrade
Process 4: Install MPMRx card(s) on the RMX 2000/4000
For more information on the upgrade process refer to the RMX® 2000/4000 MPMRx Migration Procedure that is included in your upgrade kit documentation set.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 54
Version 8.3 Detailed Description - New Features
RMX 1800 OverviewThe Polycom RealPresence Collaboration Server (RMX) 1800 system is the latest Multipoint Control Unit (MCU) in the RMX family. The RMX 1800 system is a high performance, scalable, IP-network (H.323 and Session Initiation Protocol [SIP]) MCU that provides feature-rich and easy-to-use multipoint voice and video conferencing.
The following figure shows a typical multipoint conferencing system using an RMX1800 system.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 55
Multipoint video conferencing using an RMX 1800 system
RMX 1800 Feature Changes and AdditionsThe RMX1800 system offers the key features included in the Polycom RMX 1500, RMX 2000, and RMX 4000 systems with the additions and changes shown in the following table. These features are described more fully in the sections that follow.
RMX 1800 Additions and Changes
Feature Name Description
1080p 60 content The system receives and sends content with the resolution of up to 1080p 60.
6M bit rate (CP mode) In continuous presence (CP) mode, the system transfers data with a bit rate up to
6 Mbps.
Resource capacity System capacity depends on the video resolution and the number of DSP media cards inserted.
For more information on the system capacity, see Resource Capacity .
New media card The RMX 1800 uses DSP cards as the media cards.
RMX type indication The RMX 1800 model name is shown in the web client banner and on Welcome page headings.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 56
Resource CapacityThe RMX 1800 system allocates port resources in AVC HD720p30 units. The number of unit ports each type of call requires differs for AVC-SVC mixed conferences and non-mixed conferences.Listed are the resource capacities for different system configurations, licenses, and conferencing modes.
Resource Capacity in Non-Mixed Conferences
The port consumption ratios of different calls against that of a HD 720 p30 call are as shown in this table.
for example, to make a1080p60 call, you need four 720p 30 ports; to make a 1080p 30 call, you need two 720p 30 ports; and so forth.
When the required resource is not a whole number, it’s rounded up to the nearest whole number. For example, to make an SVC call requiring1/3 of an HD 720 p30 port. In fact, one port will be allocated.
The following table lists the system capacities for each license in non-mixed conferences when the system has one DSP card.
Fast Configuration Wizard
RMX 1800 is added to the Fast Configuration Wizard. As RMX 1800 system drops the support for PSTN and ISDN, the PSTN- and ISDN-relevant configuration pages are also removed from this wizard.
Network connectivity Media, signaling and management networks can be logically separated on the RMX 1800 system to provide enhanced security.
Symmetric1080p 60 The system receives and sends video up to the resolution of HD1080p 60fps.
Port consumption ratios of different calls
HD1080p60 HD1080p30 HD720p30 AVC SD AVC CIF Audio SVC
4 2 1 0.5 0.5 0.5 0.334
Licensed capacity for systems with three DSP cards, non-mixed mode
Licensed ports HD1080p60 HD1080p30 AVC HD AVC SD AVC CIF Audio SVC
5 1 2 5 10 10 10 15
10 2 5 10 20 20 20 30
15 3 7 15 30 30 30 45
20 5 10 20 40 40 40 60
25 6 12 25 50 50 50 75
30 7 15 30 60 60 60 90
35 8 17 35 70 70 70 105
RMX 1800 Additions and Changes
Feature Name Description
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 57
The following table lists the system capacities for each license in non-mixed conferences when the system has one DSP card.
Resource Capacities in Mixed Conferences
The the port consumption of different calls in mixed conferences are shown in the following table.
Table: Port consumption of different calls, in mixed conferences (Base Ratios)
In other words, to make one 720 p30 call in a mixed conference, you need two license ports; to make one 1080 p30 call, three license ports; and so forth.
When the required resource is not a whole number, it’s rounded up to the nearest whole number. For example, to make an SVC call requiring1/3 of a license port. In fact, one port will be allocated.
40 10 20 40 80 80 80 120
45 11 22 45 90 90 90 135
50 12 25 50 100 100 100 150
55 13 27 55 110 110 110 165
60 15 30 60 120 120 120 180
65 16 32 65 130 130 130 195
70 17 35 70 140 140 140 210
75 18 37 75 150 150 150 225
Licensed capacity for systems with one DSP card, non-mixed mode
Licensed ports HD1080p60 HD1080p30 AVC HD AVC SD AVC CIF Audio SVC
5 1 2 5 10 10 10 15
10 2 5 10 20 20 20 30
15 3 7 15 30 30 30 45
20 5 10 20 40 40 40 60
25 6 12 25 50 50 50 75
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD
AVC CIF Audio SVC
NA 3 1.5 0.75 0.75 0.75 0.333
Licensed capacity for systems with three DSP cards, non-mixed mode
Licensed ports HD1080p60 HD1080p30 AVC HD AVC SD AVC CIF Audio SVC
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 58
The following table lists the system capacities for each license in mixed conferences when the system has 3 DSP cards.
Table: Licensed capacity for systems with three DSP cards, in mixed conferences
The following table lists the system capacities in non-mixed conferences when the system has one DSP card.
Licensed ports
HD1080p30 AVC HD AVC SD AVC CIF Audio SVC
5 1 3 6 6 6 15
10 3 6 13 13 13 30
15 5 10 20 20 20 45
20 6 13 26 26 26 60
25 8 16 33 33 33 75
30 10 20 40 40 40 90
35 11 23 46 46 46 105
40 13 26 53 53 53 120
45 15 30 60 60 60 135
50 16 33 66 66 66 150
55 18 36 73 73 73 150
60 20 40 75 75 75 150
65 21 42 75 75 75 150
70 23 42 75 75 75 150
75 25 42 75 75 75 150
Table: Licensed capacity for systems with one DSP card, in mixed conferences
Licensed ports
HD1080p30 AVC HD AVC SD AVC CIF Audio SVC
5 1 3 6 6 6 15
10 3 6 13 13 13 30
15 5 10 20 20 20 45
20 6 13 26 26 26 52
25 8 14 26 26 26 52
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 59
Hardware Monitor
The Hardware Monitor for RMX 1800 contains DSP media cards. From the Hardware Monitor, you can do
the following:
View DSP media card properties and alarm messages
View the chip information and the port usage of each chip for a DSP media card
Reset a DSP media card
Initial Setup Utility
The RMX 1800 is added to the choices offered in the Initial Setup Utility, which allows you to set up LAN properties for the first time power-up.
Note: About special licenses
For both mixed and non-mixed conferences, special licenses are available to provide up to 100 ports for systems configured with 3 DSP media cards, or up to 35 ports for systems with 1 DSP card.
For more information, please contact your local Polycom representative.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 60
RMX 1800 Name in the Banner
You can view the RMX 1800 model name in the system web client banner and in the Welcome page
.
Network Connectivity
In normal working mode, the RMX 1800 handles system management and IP conferencing on separate LAN ports. System management uses LAN 1; media and signaling processing use LAN 2.
When the LAN redundancy feature is enabled, LAN 1 is used for management, media and signaling network connection; LAN 2 works as the backup of LAN 1.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 61
Fast Configuration Wizard
Because the RMX 1800 system drops support for PSTN and ISDN, the following PSTN- and ISDN-relevant configuration pages are removed from the Fast Configuration Wizard:
ISDN/PSTN
PRI Settings
Span Definition
Phones
Spans
New Features in Version 8.3The RMX 1800 system was first unveiled in the China market (as V8.1.5c and V8.1.8). V8.3 is its first worldwide release.
When compared to previous releases, this release introduces the following new features:
Content to legacy endpoints
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 62
You can now send content to H.323 and SIP endpoints (legacy endpoints) that do not support H.239
content.
H.264 high profile content support
The H.264 High Profile is a new addition to the H.264 video protocol suite. It uses the most efficient
video data compression algorithms to even further reduce bandwidth requirements for video data
streams. Sending content using H.264 High Profile, you can maintain the content quality at bit rates
that are up to 50% lower than previously required.
Multiple content resolutions
You can now send content with more than one resolution to H.263 and H.264 endpoints. This allows
endpoints with different protocols to join or leave the conference without having to restart content
sharing in the middle of a conference.
1080p 30/60 content support
You can now send or receive 1080p 30/60 content.
IPv4, IPv6, and IPv4 & IPv6 mixed IP addressing environments
Version 8.3 adds support to dial in, dial out, and manage the system in the IPv4, IPv6, or IPv6 & IPv4
mixed IP addressing environment.
Support for SVC, and mixed SVC & AVC conferencing.
Version 8.3 adds support for SVC-enabled endpoints. You can also have SVC and AVC endpoints in
the same conference.
Microsoft Interactive Connectivity Establishment (ICE) implementation support
SIP endpoints can now traverse a variety of firewalls between the RMX 1800 system or other
endpoints by using the Microsoft ICE technology.
Microsoft ICE is also the only way for remote Microsoft Office Communicator or Lync users to call
into an enterprise without a VPN.
TIP
TIP is a proprietary protocol created by Cisco for deployment in Cisco Telepresence systems (CTS).
Version 8.3 allows the RMX 1800 system to inter-operate with CTS, ensuring optimum quality
multi-screen and multipoint calls.
DSP media card enabling and disabling
You can now enable or disable a specific DSP media card. This helps to isolate problems in system
troubleshooting.
Gathering phase support for AVC calls
The gathering phase of an AVC (CP only) conference is the time period during which participants
are connecting to a conference. During the gathering phase, you can view the video of connected
endpoints, along with text information about the conference.
Click and view support for AVC calls
You can now select a video layout during a conference from your endpoint.
Polycom Video Clarity™ and auto brightness
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 63
In Version 8.3, the RMX 1800 system adopts video enhancing algorithms to incoming video streams
of resolutions up to and including Standard Definition (SD).
The system can also detect and automatically adjusts the brightness of video windows that are
dimmer than other video windows in the conference layout.
Roll call
Roll call is now supported as part of the conference IVR service. The system can record the
participants’ names for playback when the participants join or leave a conference.
RTV B-frame
This version supports Microsoft RTV B-frame encoder of real-time video experience on Microsoft
Lync clients. This encoder delivers a better quality video picture by splitting a video frame into pixel
segments or slices and by predicting the pixel segments in the next video frame.
RTV FEC
This version supports Microsoft RTV FEC, which controls and corrects packet loss in receiving and
sending video streams using the Microsoft Lync Server 2010.
ITP - Picture in picture (PIP) layout and ITP cropping mode flags
You can preserve the aspect ratio of video for all telepresence modes using the system flag
ITP_CROPPING.
Personal Conference Menu (PCM)
Conference chairmen can use DTMF tone ## to bring out a local system menu on endpoints and
control the conference.
Speaker change threshold setting
You can now configure the amount of time a participant must speak continuously before becoming
the current speaker.
DTLS negotiation for content encryption
The RMX1800 system will first attempt to exchange keys using Datagram Transport Layer Security
(DTLS). If DTLS fails, SIP TLS encrypted with Session Description Protocol Security Descriptions
(SDES) is used to exchange media encryption keys.
Interoperability with Tandberg endpoints
Interoperability is now enhanced by offering the following two features:
Force HD 720p video resolution and a line rate of 2048 kbps for Tandberg endpoints.
Provide the resolution of W448p (768x448 pixels) at 25 fps for Tandberg endpoints.
Network quality indication
You can now view the network quality of either yourself or other participants from the network
indicator shown in the conference video.
Recording indication
When you record a conference, you can now display a recording indicator to all participants,
informing them that the conference is being recorded.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 64
ITP overlay layouts
You can display additional participant endpoints in 1x1 conference video layouts.
These overlay layouts are available in ITP (Telepresence) conferences only when support for
overlay layouts is included in the Polycom Multipoint Layout (MLA) application.
Hot backup
The Hot backup implements a high availability and rapid recovery solution. Two Collaboration
Servers are configured in a Master/Slave relationship: the Master MCU is active while the Slave acts
as a passive, fully redundant Hot backup of the Master MCU. All conferencing activities and
configuration changes that do not require a System Reset are mirrored on the Slave MCU five
seconds after they occur on the Master MCU.
Up to 6 Mbps bit rate.
In continuous presence (CP) mode, the system transfers data with a bit rate up to 6 Mbps.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 65
MPMRx OverviewRMX Version 8.3 supports the latest MPMRx (Media Processing Module) card which increases the RMX’s capacity and capabilities.
MPMRx GuidelinesNew MPMRx-D/MPMRx-S media cards for the RMX 2000/4000. The MPMRx cards are supported from version and 8.3 and above. When this card is installed on any RMX 2000/4000 MCU, software version downgrades are not supported.
Guidelines are:
Mixed modes with other MPM/MPM+/MPMx cards installed on the system are not supported.
ISDN support is the same as for MPMx cards, with a limit of 200 B channels.
MPMRx Fixed Mode is not supported.
Downgrading from version 8.3 with MPMRx cards on the system is not supported.
MPMRx-D Card
MPMRx-S Card
When MPMRx card is installed, the RMX operates in MPMRx Mode giving the administrator enhanced control and monitoring of Resource Capacity and usage within the system.
Two upgrade kits are provided with the RMX platform:
RMX 2000 - VRMX2000RXUP: this kit includes a power supply, control (CNTL 2000) unit and two RTM Lan cards
RMX 4000 - VRMX4000RXUP: this kit includes the new control (CNTL 4000) unit
MPMRx Conferencing CapacitiesThe table below lists the maximum conferencing capacities of RMX 4000 and RMX 2000 when used with MPMRx card(s).
MPMRx cards are supported only with D/E-type chassis and software version 8.3.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 66
System Functions MPMRx RMX 2000 MPMRx RMX 4000
Maximum number of Video participants in a conference 400 800
Maximum number of PSTN participants in a conference 400 400
Maximum number of VOIP participants in a conference 800 800
Maximum number of Audio calls per second 5 5
Maximum number of Video calls per second 2 2
Maximum number of conferences 800 800
Maximum number of Meeting Rooms 2000 2000
Maximum number of Entry Queues 80 80
Maximum number of Profiles 80 80
Maximum number of Conference Templates 200 200
Maximum number of SIP Factories 80 80
Maximum number of IP Services 4 8
Maximum number of ISDN Services 2 2
Maximum number of IVR Services 80 80
Maximum number of Recording Links 20 (default) 20 (default)
Maximum number of IVR Video Slides 150 150
Maximum number of Log Files (1Mb max.) 8000 8000
Maximum number of CDR Files 2000 4000
Maximum number of Fault Files 1000 1000
Number of Participant alerts Unlimited Unlimited
Maximum number of concurrent RealPresence Collaboration Server Web Client connections to the MCU
20 20
Maximum number Address Book entries 4000 4000
Maximum number of Users 100 100
Maximum number of Gateway Profiles 80 80
Maximum number of Reservations (internal Scheduler) 4000 4000
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 67
MPMRx System Mode MPMRx Mode is the mode in which the RMX operates to fully utilize the increased power and
capacity of MPMRx cards. With version 8.3 MPMRx mode is the default mode on startup. However, if the RMX has been set to the MPMx mode and an MPMRx card is inserted, the RX card will be powered down.
Operating Mode Selection During Startup / Restart
When version 8.3 software is installed, the RMX enters the MPMRx Mode by default. However, after upgrade you are required to reset the RMX.
MPMRx Resolutions
The Maximum Resolution of the RMX can be set to one of the following:
HD1080p60
HD1080p30
HD720p60
HD720p30
SD60
SD30
CIF60
CIF30
When MPMx, and MPM+ and MPMcards are installed in the system they cannot be used and must be removed.
The RMX 2000/4000 only operates in the MPMRx mode with MPM-Rx cards.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 68
Resolution ConfigurationThe title for the Detailed Configuration AVC/CP section of the Resolution Configuration section shows that the resource allocation is based on AVC/CP. Explanations as to how many resources are utilized by each resolution are not shown.
RMX 2000/ RMX 4000 MPMRx Resource CapacitiesThe following sections list the resource capacities of the RMX 2000/4000.
RMX 2000/ RMX 4000 Resource Capacities in Video Switching (VSW) Conferences
The table below lists the maximum resource capacities of RMX 2000/RMX 4000 per line rate in VSW conferences (line rate being the deciding factor) when used with MPMRx cards.Resource Capacities in Video Switching (VSW) Conferences
Resource Type and Line Rate Resources with MPMx Resources with MPMRx
VSW 2Mb 160 200
VSW 4Mb 80 100
VSW 6Mb 40 60
ISDN 7 E1 or 9 T1(per RTM ISDN card)
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 69
MPMRx Resource Capacities in Non-Mixed CP and SVC Conferences
The port consumption ratios of different calls against that of a HD720p30 call are as shown in this table.
In other words, to make one1080p60 call, you need 4x 720p 30 ports; to make one 1080p 30 call, 2x 720p 30 ports; and so forth.
When the required resource is not a whole number, the system may round it up to the nearest whole number as in the case of the port Port Gauge. For example, to make an SVC call requiring 1/3 of an HD720p30 port, one port will appear allocated.
MPMRx-D Non-Mixed Port Resource Capacities
The following table lists the system capacities for each license in non-mixed conferences.
Licensed Capacity for Systems with MPMRx-D card, Non-Mixed Conferences
Port consumption ratios of different calls
HD1080p60 HD1080p30 HD720p30 AVC SD AVC CIF Audio SVC
4 2 1 0.5 0.5 0.5 0.334
Licensed ports
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD AVC CIF Audio SVC
5 1 2 5 10 10 10 15
10 2 5 10 20 20 20 30
15 3 7 15 30 30 30 45
20 5 10 20 40 40 40 60
25 6 12 25 50 50 50 75
30 7 15 30 60 60 60 90
35 8 17 35 70 70 70 105
40 10 20 40 80 80 80 120
45 11 22 45 90 90 90 135
50 12 25 50 100 100 100 150
55 13 27 55 110 110 110 165
60 15 30 60 120 120 120 180
65 16 32 65 130 130 130 195
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 70
MPMRx-S Non-Mixed Port Resource Capacities
The following table lists the system capacities for each license in non-mixed conferences.
Licensed Capacity for Systems with MPMRx-S card, Non-Mixed Conferences
MPMRx Resource Capacities in CP and SVC Mixed Conferences
The following table shows the port consumption ratios of different calls against that of an HD720p30 call.
Port Consumption Ratios, in Mixed Conferences
In other words, to make one1080p30 call, you need 3x 720p30 ports; to make one 720p30 call, 1.5x 720p30 ports; and so forth.
When the required resource is not a whole number, the system may round it up to the nearest whole number as in the case of the port Port Gauge. For example, to make an SVC call requiring 1/3 of an HD720p30 port, one port will appear allocated.
MPMRx-D Mixed Port Resource Capacities
The following table lists the system capacities for each license in mixed conferences.
Licensed Capacity for Systems with MPMRx-D card, Mixed Conferences
Licensed ports
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD AVC CIF Audio SVC
5 1 2 5 10 10 10 15
10 2 5 10 20 20 20 30
15 3 7 15 30 30 30 45
20 5 10 20 40 40 40 60
HD1080p60 HD1080p30 HD720p30 AVC SD AVC CIF Audio SVC
NA 3 1.5 0.75 0.75 0.75 0.3333
Licensed ports
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD AVC CIF Audio SVC
5 NA 1 3 6 6 6 15
10 NA 3 6 13 13 13 30
15 NA 5 10 20 20 20 45
20 NA 6 13 26 26 26 60
25 NA 8 16 33 33 33 75
30 NA 10 20 40 40 40 90
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 71
MPMRx-S Mixed Port Resource Capacities
The following table lists the system capacities for each license in mixed conferences.
Licensed Capacity for Systems with MPMRx-S card, Mixed Conferences
Total Resource Capacities per MPMRx-D Card in CP & SVC Conferences
The RMX system allocates port resources in AVC HD720p30 units. The number of ports used for each types of calls differs between AVC-SVC mixed conferences and non-mixed conferences.
The table below lists the maximum resource capacities of RMX 4000 and RMX 2000 per resolution in CP Conferencing and SVC modes when used with MPMRx-D card.
Total Resource Capacities per MPMRx-D Card
35 NA 11 23 46 46 46 105
40 NA 13 26 53 53 53 120
45 NA 15 30 60 60 60 135
50 NA 16 33 66 66 66 150
55 NA 18 36 73 73 73 150
60 NA 20 40 75 75 75 150
65 NA 21 42 75 75 75* 150
Licensed ports
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD AVC CIF Audio SVC
5 NA 1 3 6 6 6 15
10 NA 3 6 13 13 13 30
15 NA 5 10 20 20 20 45
20 NA 6 12 22 22 22 45*
25 NA 8 12* 22* 22* 22* 45*
Resolutions Non-Mixed Endpoints Mixed Endpoints
Audio 130 75
AVC SD 130 75
AVC CIF 130 75
SVC 195 150
HD720p30 65 42
Licensed ports
AVC HD1080p60
AVC HD1080p30
AVC HD720p30
AVC SD AVC CIF Audio SVC
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 72
Total Resource Capacities per MPMRx-S Card in CP & SVC Conferences
The RMX system allocates port resources in AVC HD720p30 units. The number of ports used for each types of calls differs between AVC-SVC mixed conferences and non-mixed conferences.
The table below lists the maximum resource capacities of RMX 4000 and RMX 2000 per resolution in CP Conferencing and SVC modes when used with MPMRx-S card.
Total Resource Capacities per MPMRx-S Card
HD720p TIP 65 42
HD720p RTV 65 42
HD1080p30 32 21
HD1080p60 16 NA
Resolutions Non-Mixed Endpoints Mixed Endpoints
Audio 40 22
AVC SD 40 22
AVC CIF 40 22
SVC 60 45
HD720p30 20 12
HD720p TIP 20 12
HD720p RTV 20 12
HD1080p30 10 6
HD1080p60 5 NA
Resolutions Non-Mixed Endpoints Mixed Endpoints
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 73
System Information Change
The number of CP licenses are reported as HD720p30 ports. When a license is upgraded, it is converted to HD720p30 ports at a ratio of 3 CIF CP ports to 1 HD720p30 port.
Switching to the MPMRx Configuration Mode
Prior to switching card configuration modes you must first perform a software upgrade to RMX version 8.3.x.
Example 1:
Current status
An RMX has two MPM+ cards installed.
The Card Configuration Mode is MPM+.
Both MPM+ cards are enabled.
Action
» Upgrade the RMX software version to 8.3.x, remove the MPM+ cards and insert an MPMRx card(s).
Result
The Card Configuration Mode remains MPM+. The inserted MPMRx card is disabled.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 74
After System Reset
The Card Configuration Mode is MPMRx.
The inserted MPMRx card is enabled.
Example 2:
Current status
An RMX has one MPMx card installed.
The Card Configuration Mode is MPMx and the MPMx card is enabled.
Action
» Upgrade the RMX software version to 8.3.x, remove the MPMx card and insert an MPMRx card.
Result
The Card Configuration Mode remains MPMx.
The inserted MPMRx card is enabled.
After System Reset
The Card Configuration Mode is MPMRx.
The inserted MPMRx card is enabled.
Example 3:
Current status
An RMX has MPMx card installed.
The Card Configuration Mode is MPMx and the MPMx card is enabled.
Action
» Upgrade the RMX software version to 8.3.x, remove the MPM+ card and insert an MPMRx card.
Result
The Card Configuration Mode remains MPMx.
The inserted MPMRx card is enabled.
After System Reset
The Card Configuration Mode is MPMRx
The inserted MPMRx card is enabled.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 75
New MPMRx FlagA new MPM-Rx only flag has been added to the RMX. The following System Flag must be added to system.cfg - MCMS user section if the value is to be modified:
LIMIT_SD_AND_CIF_BW_MPMRX - Limits the maximum negotiated and opened bit rate for resolutions equal or lower than SD to 1Mbps. When set to NO, there is NO limitation on SD and CIF bit rates.
a Default: YES.
b Range: YES/NO.
MPMRx Hardware MonitoringThe status and properties of the MPMRx Card can be viewed and monitored in the Hardware Monitor list pane. The Hardware monitor pane displays the number of MPMRx card installed on the RMX 2000/4000. For more information, see the RMX 1500/1800/2000/4000 Administrator’s Guide, RMX Hardware Monitoring.
MPMRx Properties
To View the Supporting Hardware Components Properties:
In the Hardware Monitor pane, either double-click or right-click and select properties for the desired supporting hardware component.
The component’s properties dialog box will appear with the tabs displayed.
The UI above displays the RMX 4000.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 76
MPMRx General Info tab
MPMRx Event Log tab
MPMRx Active Alarms tab
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 77
MPMRx Hardware Diagnostics
Diagnostics can be performed on the MPMRx card(s) when the MCU is in Diagnostics mode.
To Monitor the MPMRx Card:
In the Hardware Monitor pane select the MPMRx card and click Diagnostics from the drop-down menu. For more information, see the RMX 1500/1800/2000/4000 Administrator’s Guide, Diagnostic Mode (RealPresence Collaboration Server (RMX) 1500/2000/4000).
MPMRx Resource ReportThe basic unit used for reporting video resource usage in the Resource Report is HD720p30 CP. Results are rounded to the nearest integer. The MPM-Rx does not support the Fixed Resource Capacity mode.
For more details about Resource Report, see the RMX 1500/1800/2000/4000 Administrator’s Guide, "Resource Report” on page 21-16.
Port Gauge ChangeThe basic unit used for reporting resource usage in the Port Gauges is HD720p30 CP. Results are rounded to the nearest integer.
Video/Voice Port Configuration ChangeFixed Resource Capacity mode has been disabled in the Video/Voice Port Configuration. If Fixed Resource Capacity mode is being used at the time of the upgrade, Flexible Resource Capacity mode will automatically be used. The settings from the last time Flexible Resource Capacity mode was used on the RealPresence Collaboration Server will be implemented when the upgrade is complete.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 78
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - New Features
Polycom, Inc. 79
Gateway Calls to Remote SIP DomainThe RMX’s Gateway functionality has been enhanced, enabling the connection of H.323 and SIP endpoints residing in a domain, to SIP endpoints residing in a remote domain.
Guidelines The calling endpoint may be H.323 or SIP.
The destination endpoint must be SIP.
RMX 1800 is not supported as it does not yet support Gateway functionality.
Calling a SIP Endpoint in a Remote DomainThe dial string from the calling endpoint to the RMX includes the gateway dial-out number of the SIP endpoint that is located in the remote domain.
By definition, a dial-in string cannot contain two domains and it is therefore necessary that the dial string be of the following format:
mcu-meeting-room*dest%40dest-domain@mcu-domain
Where:
The domain of the gateway call is mcu-domain
The remote destination domain is dest%40dest-domain.
The “%40” is replaced with an “@” when the gateway call is dialed to the remote SIP destination.
Limitation DTMF tones and Caller-id are not passed end-to-end.
In order to support RTV, the SIP Server Type must be defined as Microsoft.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 80
Version 8.3 Detailed Description - Changes to Existing Features
HD1080p60 Symmetric Resolution SupportFrom Version 8.3, the Collaboration Server supports HD1080p60 video resolution symmetrically; both receiving and sending HD1080p60 video resolution.
Guidelines for Using HD1080p60 Video Resolution Symmetrically
HD1080p60 video resolution is supported symmetrically:
On MPMRx media cards only.
With H.264 video protocol.
For conference profiles with Video Quality set to Motion.
For H.323 and SIP participants.
At line rates up to 4Mbps.
HD1080p60 video resolution is not supported symmetrically:
In 1X1 layouts, including 1X1 layouts in Telepresence Mode. Instead, the Collaboration Server transmits the current speaker endpoint’s video resolution and frames per second.
In TIP environments.
For ISDN participants.
For Content sharing.
With RTV video protocol.
Video Switching (VSW) mode is unchanged supporting HD1080p60 Symmetric Resolution at line rates up to 6Mbps.
For information about resources consumed by HD1080p60 resolution see Resource Capacity. There are 65 video resources per MPMRx card, with four ports consumed per participant connected at HD1080p60 video resolution. A total of 25 HD1080p60 connections are supported per MPMRx card.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 81
Selecting HD1080p60 Symmetric Video Resolution
HD1080p60 video resolution is selected in the Motion tab of the Resolution Configuration dialog box.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 82
HD1080p30 and HD1080p60 Content SupportBeginning with Version 8.3, Content is supported at resolutions of HD1080p30 and HD1080p60 in both Base and High Profiles.
HD1080p30 and HD1080p60 Content Support GuidelinesHD1080p30 Content is supported:
On Realpresence Collaboration Server model 1800.
On Realpresence Collaboration Server models 2000 and 4000, with MPMRx cards installed.
At a maximum content rate of 2048 kbps on Realpresence Collaboration Server models 1800, 2000 and 4000.
4096 kbps is the maximum content rate for 1080p60.
HD1080p30 and HD1080p60 Content are supported:
On the Realpresence Collaboration Server 1800.
In the normal (switched) Content mode.
In AVC-CP conferencing mode only.
With SIP and H.323 endpoints
With the H.263 and H.264 Auto Selection, H.264 HD and H.264 Cascade and SVC Optimized. Content protocol options.
With Customized Content Rates.
In (H.323) Cascaded conferences.
On Legacy Endpoints when the Send Content to Legacy Endpoints option is selected.
Content is shared using the video channel.
HD1080p30 and HD1080p60 Content are not supported:
By MCUs containing MPMx cards.
With RealPresence® Content Sharing Suite for Microsoft® Lync® endpoints.
By ISDN endpoints.
When TIP compatibility is set to Prefer TIP or Video and Content.
TIP Content is shared at XGA Resolution at 5 frames per second.
By H.263 Content Protocol.
In Content Transcoding mode.
If the Content was defined as High Profile, endpoints which support only Base Profile Content will not be able to receive Content using the Content channel. If the Send Content to Legacy Endpoints option is selected they can receive Content shared using the video channel.
Sharing Base and High Profile Content with HD1080p30/60 ResolutionIn Base Profile, Content sharing at the new 1080p30 and 1080p60 rates will behave as in previous versions:
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 83
In non-Cascaded environments Content Video Switching mode, Content sharing rate, resolution and frame rate is negotiated according to the capabilities of highest common capabilities of all endpoints connected to the conference. Endpoints which do not support High Profile will not receive content through the Content channel.
In Cascaded environments Content sharing rate, resolution and frame rate must be pre-defined and endpoints which do not support these capabilities will not receive content though the Content channel.
For more information see the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Administrator’s Guide, Multiple Content Resolutions.
Changes to the Video Quality Dialog BoxAn additional check box H.264 High Profile and an additional Content Rate drop-down menu have been added to the Video Quality dialog box.
The H.264 High Profile check box is un-checked by default and is displayed next to the Content Protocol drop-down menu if all the following conditions are met:
The MCU is a Realpresence Collaboration Server 1800, or 2000/4000 containing MPMRx cards.
The selected Conferencing Mode is AVC-CP.
Multiple Resolutions (Content Transcoding) is not selected.
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 84
The selected Content Protocol is H.264 HD, H.264 Cascade and SVC Optimized or H.263 and H.264 Auto Selection.
If H.264 HD, H.264 Cascade and SVC Optimized is selected, the Content Resolution is set according to the line rate.
If H.263 and H.264 Auto Selection is selected, the Content Resolution is automatically set according to the line rate and the H.264 High Profile check box is automatically unchecked and disabled.
TIP Compatibility (in the Profile - Advanced dialog box) is selected as None or Video Only.
The conference Line Rate is sufficient to support HD1080p30/60 content.
For more information about conference line rates and allocated content rates, see the following tables and the RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide, Content Sharing.
The Content Rate drop-down menu is displayed next to the Content Resolution drop-down menu when:
H.264 Cascade and SVC Optimized is the selected Content Protocol
and
CustomizedContentRate is the selected Content Setting.
The Content Rate is dependent on the MCU type (Realpresence Collaboration Server with MPMRx or Realpresence Collaboration Server 1800) and can be up to 66% of the conference line rate. In MCUs with MPMRx cards the Content Rate is limited to 2048 kbps, while when used with the Realpresence Collaboration Server 1800 the Content Rate is limited to 4096 kbps.
Conference Line Rate and Content Allocation Rate for Base Profile
Bit Rate Allocated to ContentChannel (Kbps)
Content
Maximum Resolution Frames/Second
64-512 H.264 HD720 5
512-768 H.264 HD720 30
768-1536 H.264 HD1080 15
1536-2048 / 3072 (Realpresence Collaboration Server 1800)
H.264 HD1080 30
3072-4096 H.264 HD1080 60
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 85
Highest Common Content Bit Rate Allocation for Base Profile
* 2560 (Realpresence Collaboration Server 1800)
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 86
Bit Rate Allocation to Content Channel per Conference Line Rate for H.264 Cascade and SVC Optimizedfor Base Profile
*3072, ‡2560 (Realpresence Collaboration Server 1800)
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 87
Conference Line Rate and Content Allocation Rate for High Profile
Highest Common Content Bit Rate Allocation for High Profile
Bit Rate Allocated to ContentChannel (Kbps)
Content
Maximum Resolution Frames/Second
64-384 H.264 HD720 5
384-512 H.264 HD720 30
512-768 H.264 HD1080 15
768-2048 H.264 HD1080 30
2048-4096 H.264 HD1080 60
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 88
Bit Rate Allocation to Content Channel per Conference Line Rate for H.264 Cascade and SVC Optimizedfor High Profile
RMX Release Notes Version 8.3 Version 8.3 Detailed Description - Changes to Existing Features
Polycom, Inc. 89
6Mbps Line Rate Supported on RealPresence Collaboration Server (RMX) 1800
Support of 6Mbps Line Rate in AVC-CP ConferencesFrom Version 8.3, the RealPresence Collaboration Server (RMX) 1800 supports AVC-CP conferences at line rates up to and including 6Mbps. In previous versions, a 6Mbps line rate was only supported in Video Switching (VSW) conferences. (VSW is not supported by RMX 1800).
General Guidelines for Using 6Mbps Line Rate
Support is for Dial-in calls only.
The 6Mbps line rate is used for HD1080p30/60 and HD720p60 resolutions.
To prevent excessive bandwidth usage and resource consumption, the system will ignore a Line Rate of 6Mbps defined in the Profile, substituting line rates appropriate to the Maximum Resolution defined.
If the Conferencing Mode is changed from AVC-CP to SVC Only or CP and SVC conferencing mode, the line rate should also be changed to 1920Kbps, which is the default line rate for this conferencing mode.
If a the selected conference Line Rate and Conferencing Mode are not compatible an error message is displayed:
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 90
Corrections and Known Limitations
Corrections Between Version 8.2 and Version 8.3
Issue ID Category Description Found in
BRIDGE-10767
Video CLONE - FIELD - Video Layout shows only video from a single participant in a conference with multiple participants
V7.8.0
BRIDGE-1307
RMX Web Client Connection to RMX is lost due to Internal MCU resetMcmsDaemon reset resulting from Mcms request: No connection with Switch.
V7.8.0
BRIDGE-1491
RMX Web Client In Entry Queue IVR Service Video Services dialog box, the Delete Slide button is displayed in English in the Russian User Interface.
V7.8.0
BRIDGE-1493
General In the IVR Services, Video Services tab, the Invite Participant section is not translated.
V7.8.0
BRIDGE-1574
General After a participant connects to the conference, when accessing the participant's properties in the Advanced tab, Endpoint Type and Call bit Rate fields are not translated.
V7.8.0
BRIDGE-1576
Multilingual When using the RMX Manager or Web Client in Turkish, "FECC Token" in the Channel Status tab of the properties of a participant is not translated into Turkish.
V7.8.0
BRIDGE-1579
Multilingual When using the RMX Manager or Web Client in Turkish, the "Use Entry Tone" option in the Roll Call/Notifications tab of a New Conference IVR Service is not translated into Turkish.
V7.8.0
BRIDGE-1597
Multilingual When using the RMX Manager or Web Client in Russian, the "Conference Mode", Vertical Position", and "Background Transparency" fields of the Message Overlay tab of a new profile are not translated into Russian.
V7.8.0
BRIDGE-1602
RMX Web Client Conferencing Mode field and Note texts are displayed in English in Profiles Skins dialog box in Russian User Interface.
V7.8.0
BRIDGE-1604
RMX Web Client In the Administration, Tools menu some fields are displayed in English in the Russian User Interface.
V7.8.0
BRIDGE-1605
Multilingual When creating a profile while using the RMX Manager or Web Client in Russian, the, "Conferencing Mode" and, Video Clarity" fields of the Video Quality tab are not translated. In addition, in the Video Settings tab the, "Same Layout" and, "TelePresense Layout Mode" fields are cut off.
V7.8.0
BRIDGE-1607
RMX Web Client GMT Time is displayed in Hebrew in Administration >CDR list in Russian User Interface.
V7.8.0
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 91
BRIDGE-1610
Multilingual When hovering over the, "Import Conference Templates" and, "Export Conference Templates" buttons in the RMX Manager or Web Client while using the RMX Manager or Web Client in Russian, the tool tips are displayed in English.
V7.8.0
BRIDGE-1611
RMX Web Client In the SNMP Properties, Security tab, the Security Level and Authentication Protocol fields are not translated.
V7.8.0
BRIDGE-1616
General In the Notification Settings pane, New Connection, Conference not Full, New Conference Created, Active Alarms Update, Welcome Message, and Fault List Updated fields are not translated.
V7.8.0
BRIDGE-1617
General In the Directory Services window, the field: Administrator - Read Only is not translated.
V7.8.0
BRIDGE-2205
Security When the MAX_PASSWORD_REPEATED_CHAR is changed the MCU needs to be reset.
V7.8.0
BRIDGE-242
SIP When the "auto connection" check box is unchecked in the SIP factory's properties and endpoints dial into a SIP Factory, multiple conferences are started but the endpoints never connect.
V7.8.0
BRIDGE-246
Interoperability A Sony PCS-G50 endpoint stops sending video when the Sony PCS-XG80 sends content while both endpoints are connected via H.323 to the conference.
V7.8.0
BRIDGE-287
Interoperability CTS Gathering slide is pixelated and of poor quality when connected to conference on RMX registered to RealPresence DMA system.
V7.8.0
BRIDGE-3062
Audio In the New Profile – Audio Settings tab, the Echo Suppression field still appears in the UI, when it should not.
V8.1
BRIDGE-320
General When forbidden characters are used in the conference name, when retrieving the CDR file an error message will appear "Invalid Directory or path".
V7.8.0
BRIDGE-322
RMX Manager Active Directory user cannot open the Hardware Monitor section in the RMX Manager.
V7.8.0
BRIDGE-360
Interoperability When an Sametime Unified Telephony client connects to an RMX 2000 conference using SIP or H.323, after entering the conference ID only the lobby video is shown if the Sametime Unified Telephony client is the only participant.
V7.8.0
BRIDGE-401
Software Version User Customization of Audible Alarms for Awaiting Operator Assistance function returns "value is out of range" message when both the number of repetitions and repetitions interval in seconds parameters are modified.
V7.8.0
Issue ID Category Description Found in
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 92
BRIDGE-404
Content In a conference with Send content to Legacy Endpoint enabled, an RPM endpoint cannot receive content but does see video. When content is stopped and then restated the RPM endpoint does view content.
V7.8.0
BRIDGE-430
General In a 512kbps CP conference without encryption with several dial-in endpoints some of the endpoints use the personal layout and not the conference layout.
V7.8.0
BRIDGE-444
IP After setting an RMX 2000 with an MPM+ card to use both IPv4 and IPv6 and attempting to use the Web Client using IPv6 addresses, the following error message is displayed: "Browser environment error. Please reopen the browser
V7.8.0
BRIDGE-515
Upgrade Process When initiating a downgrade from version 7.6 to 7.5.0/ 7.5.1 on the RMX 1500Q, the Safe Software Version Installation alarm message is not generated warning that you cannot perform the downgrade.
V7.8.0
BRIDGE-578
Upgrade Process After adding the Activation key and the upgrade process continues to run, the active alarm does is not deleted and the message "A matching activation key is required" remains.
V7.8.0
BRIDGE-677
Video An HDX 9004 connecting at a maximum of 786k to an RMX 2000 with MPMx card may display green splotches on the Welcome slide.
V7.8.0
BRIDGE-734
General During a conference with H.264, when starting Click&View from a Legacy endpoint, after pressing "0" repeatedly, different layouts appear each with or without content.
V7.8.0
BRIDGE-846
General On a desktop with 64 bit Windows 7 and Internet Explorer 8 installed, when viewing conference participants and selecting View Participant Sent Video" from the participant right-click menu, an exception occurs.
V7.8.0
Issue ID Category Description Found in
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 93
Version 8.3 Known Limitations
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
BRIDGE-10055
CLONE - On a Lync hosted conference, a Lync client dials a RMX Lync address which launches a conf in a pre-defined RMX mtg room and a dial-in participant is c
V8.1.7
BRIDGE-10060
Content NGB >> Content >> V8.3.0.96 >> HP content >> After rate downgraded for content an H.323 GS get CIF@60FPS video instead of 30FPS
V8.3
BRIDGE-10067
Ninja WW >> Performance >> 8.3.0.108 >> some DSP possible be died in long time connectivity test.(auto recovery successful)
V8.3
BRIDGE-1012
Multilingual The presence status of Meeting Rooms connected to the Microsoft Lync Server might be set to "Offline" instead of "Available" when the Lync Server is reset.
V7.8.0
BRIDGE-10123
Audio CESC / Q4 2013 Pretest / Siemens / RMX : No audio in RMX encrypted dial-out call for Siemens End points(OpenStage & ODC)
V8.3
BRIDGE-10123
Interoperability In a conference, if a Lync participant and a RealPresence Group participant hold their call simultaneously and then resume the call several minutes later, it takes around two minutes before the Lync participant can receive the video again.
BRIDGE-10268
IVR CLONE_FIELD - When systems call into a conference with IVR enabled with Roll call. If the sites presses the # sign after stating their name they enter the conferenc
V7.8.0
BRIDGE-1027
General CS baseline in the Comlog problems during RMX startup.
V7.8.0
BRIDGE-1028
Interoperability A V500 endpoint connects as secondary when dialing-out from an RMX in a H.264/CIF Video Switching conference at 128Kbps.
V7.8.0
BRIDGE-10299
Interoperability CESC / Q4 2013 TestPass1 / IBM / RMX - RMX Controls (Suspend/Resume Video) not working properly for IBM Sametime Clients
V8.3
BRIDGE-1033
Encryption Non-encrypted H.323 endpoint cannot connect to conference with profile set to "Encrypt when possible".
V7.8.0
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 94
BRIDGE-10331
Content During a conference with Multiple Content Resolutions, H.263, and H.264 enabled, if H.263 and H.264 endpoints send content alternatively, the content switch is not smooth sometimes.
BRIDGE-10345
Interoperability CLONE - RMX sends wrong SDP after Reinvite V7.8.0
BRIDGE-10349
NGB >> V8.3.0.137>> RL: AVC [CP] Mode: Clients Failed to re-connect to conf
V8.3
BRIDGE-10377
General CLONE_FIELD - ELITE - RMX 7.8.0.246.055 rebooted during the night after High CPU usage alarm
V7.8.0
BRIDGE-10400
General CLONE - FIELD core dump file created in the morning when unit was out of load.
V7.7
BRIDGE-10403
General CLONE - FIELD RMX2000 is auto reboot twice on Nov 21.
V7.8.0
BRIDGE-10439
Resource Capacity
Performance >> CloudAxis >> AVC capacity test >> 8.3.1.23/8.3.0.139 >> after loading on MCU some EP connecting with "waiting for dial in" status
V8.3, V8.3.1
BRIDGE-10473
Video [Android]There is one bright border on the bottom of video window when rpm android join in the mixed conference with avc
V8.3
BRIDGE-10513
Partners - Microsoft
CLONE - AA: Lync clients seeing 'red bars' when connected to RMX because of high reported jitter rates incorrectly reported by RMX-
V8.1.7
BRIDGE-10515
General CLONE - FIELD RMX crashed spontaneously, root cause requested-
V7.8.0
BRIDGE-10516
General CLONE - FIELD RMX v7.8.0.246 uses guid value as a conference ID parameter in IRR which causes HCNET 3rd party GK to send DRQ to RMX and RMX disconnects EPs.
V7.8.0
BRIDGE-10519
Interoperability CESC / Q4 2013 Testpass1 / Avaya/ RMX - RMX(NGB) calls not working.
V8.3
BRIDGE-10586
ISDN [verify v8.4]CLONE - CESC / IntraOp / Q4 2013 TestPass1 / NGB ISDN - RMX stops sending video to endpoint after a short time in ISDN calls.
V8.3
BRIDGE-10628
Interoperability NGB >> TIP 720p Video >> V8.3.0.159 >> Fall back HDX gets 720p60 although conf is Sharpness
V8.3
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 95
BRIDGE-10650
Interoperability AT&T SP Lab MR / CTS 3010/ TX9000 gets disconnected from the conference
V8.3
BRIDGE-10655
Gateway CLONE - CESC / Q4 2013 TestPass1 / IBM - Voice call fails to escalate to Video over RMX Gateway Profile.
V8.3
BRIDGE-10684
Interoperability [verify v8.4]CESC / InterOp / Q4 2013 TestPass1 / Q4 2013 TestPass2 / SIP TLS / RadVision XT5000 - RV disconnects after a short time when the call is with SIP TLS.
V8.3
BRIDGE-10722
Cascading CLONE - PROJECT - Barco - DMA cascade for bandwidth creates 2 cascaded conferences, but the dtmf (chair) does not seem to function correctly over the cascade
V8.1.7
BRIDGE-10765
Video IPv6 SVC >> 8.4.0.1 >> Can see only the speaker on Groups during IPv6 SVC Only conference
V8.3, V8.3.1, V8.4
BRIDGE-10772
Partners - Microsoft
CLONE - FIELD - RMX 7.8.0.246.061-Lync 2010 stops routing calls to RMX after 2 or 3 weeks.A reboot of the RMX resolved the Lync routing issues.
V7.8.0 Restart the RealPresense Collaboration Server
BRIDGE-10783
ISDN CLONE FIELD - RCA - Bridge fails to accept incoming calls.. " phone device stuck into the entry queue - VTC endpoint receive busy tone
V7.8.0
BRIDGE-10788
Content CLONE - CESC / IntraOp / Q4 2013 TestPass2 / RMX1800 Content - When SIP HDX transmits Content in RMX 4Mb call, H.323 HDX receive it deformed.
V8.3
BRIDGE-10808
Audio Performance >> CloudAxis >> audio only test >> 8.3.1.60/8.3.0.170 >> HDX SIP dial in rate of 64K reaching to the conference and disconnect immediately
V8.3, V8.3.1
BRIDGE-10809
Video NGB >> TIP Video + Content >> 8.3.0.171 >> After Going back from TIP to normal layout the Border is distorted
V8.3
BRIDGE-10815
Content CESC / Q4 2013 TestPass2 / MSM - Content was not received in GS when it was sent from GS connecting AS SIP to RMX conference
V8.3
BRIDGE-10902
IVR CLONE - CESC / Q4 2013 TestPass2 / MSM - SIP call through DMA VEQ didn't connect when 'External IVR Control' EQ in RMX was selected, IVR was not heard
V8.3
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 96
BRIDGE-10956
Interoperability CESC / Q4 2013 Testpass2 / Siemens / RMX: Call resume from openstage is not successful in a RMX dial-in call.
V8.3
BRIDGE-10970
Interoperability CLONE - GA - 8.3.1 >> Lync 2013 >> External client not open video in when esclation to video happens
V8.3
BRIDGE-10974
Interoperability Content sharing from H.320 client causes issues V8.1.4
BRIDGE-11090
Video CLONE - Performance >> CloudAxis \ RX>> Soak \ SVC Load smoke >> 8.4.0.1/8.3.0.191>> RPD getting layout of 1*1 after moving from ad hoc EQ to conference
V8.3
BRIDGE-11193
Interoperability CLONE - field CSS Plug in for Lync Add on is not getting connected to the conference with out passcode. Hence not able to share the content from Lync in conferences
V8.1.7
BRIDGE-11211
Video AT&T SP Lab MR / ISDN HDX connected to RS conference sees CP layout (sees all participants)
V8.3
BRIDGE-1123
Interoperability HDX video not recorded by manually started recording of an ongoing conference. VVX video is recorded. Recording, started automatically at conference start records correctly. Components include: RSS registered to RealPresence DMA system; DMA configured with Broadsoft as external SIP peer; VMRs configured on DMA; RMX configured with DMA; Recording links on RMX; HDX and VVX directly registered to Broadsoft.
V7.8.0
BRIDGE-1128
General On a Desktop with Windows 7 and Internet Explorer 9.0 installed, the RMX Client does not load due to Browser Error. Workaround: Install certificates using Internet Explorer in the certificate popup page.
V7.8.0
BRIDGE-11294
Content JAPANTESTLAB / RMX2000 Series / 8.3 release / In a conference of 120 participants, content keep showing on HDX monitor even after sending content has been stopped.
V8.3
BRIDGE-11301
Video CLONE - MRC SVC - The layout keeps changing when limit the downlink bandwidth in the SVC conference
V8.3
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 97
BRIDGE-11350
RTM- When system in ULTAR Secure mode the following alerts appear :Invalid Sysytem Configuration "
V8.1.4 Manually modify the flag value.
BRIDGE-1139
Multilingual When using the RMX Manager or Web Client in any language other than English, the Send Certificate Button in the Certificate Repository window is not translated into any language.
V7.8.0
BRIDGE-11395
Audio Performance >> CloudAxis >> Soak mix >> 8.3.0.207/202 >>after soak AVC EPs get noisy sound from SVC percipients
V8.3
BRIDGE-11399
CESC / IntraOp / Q4 2013 RRI / H.323 Token Wars - Cannot steal Content between two H.323 parties. (REGRESSION)
V8.3
BRIDGE-11403
Content 8.3.0.219>>NGB&Ninja cascading+content transcoding>> Wrong content out resolution in NGB&Ninja cascading+content transcoding environment.
V8.3
BRIDGE-11406
Video CLONE FIELD - As RMX does not send the updated SAR to each destination HDX, so the HDX keeps displaying 4:3 video instead of 16:9 even though the source of HDX send
V7.8.0
BRIDGE-11410
HD Performance >> CloudAxis >> Soak AVC>> 8.3.0.202/7 >>after soak any H323 EPs freeze or getting very low bit rate
V8.3
BRIDGE-11461
Multilingual RMX1800 >> EMA >> 8.3.0.228 >> the EMA alert 'SSH is enbled' does not transleted into Chinese correctly
V8.3
BRIDGE-11469
CLONE - V8.1.4.95 Pre RTM secure mode - unsuitable Bios for JITC
V8.1.4
BRIDGE-1166
Interoperability During an H.323 to H.320 gateway call to an RMX meeting room, a Tandberg Edge95 MXP endpoint does not receive content from a Cisco C20 endpoint.
V7.8.0
BRIDGE-1167
General After upgrading the RMX 4000 to version 7.7 and installing certificates they do not appear in the Certification Repository page. An RMX reset is required to update the Certification Repository page.
V7.8.0
BRIDGE-1170
Video HDX 4000/8000 connects at 720p instead of 1080p to 2.5Mb, TIP: Video & Content, RMX Multi-POCN conference.
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 98
BRIDGE-1176
Video QCIF resolution option is not listed in the Profiles, Video Quality, Maximum Resolution menu.
V7.8.0
BRIDGE-1229
Interoperability OTX layout changes in a Telepresence Enabled conference when a H.323 EP starts sharing Content. OTX displays Content on all three screens.
V7.8.0
BRIDGE-1378
General When using all the video resources while connecting participants simultaneously at a resolution of H.264 HD720p and H.263 CIF, if the HD720p participant is the last participant to connect, the actual connection resolution will be H.263 CIF and not H.264 HD 720p.
V7.8.0 Connect the H.264 HD 720p participants first and then connect the H.263 CIF participants.
BRIDGE-1488
RMX Web Client
In the Profile Properties Video Settings dialog box, some field descriptions are incomplete in the Russian User Interface.
V7.8.0
BRIDGE-1490
RMX Web Client
In Hardware Monitor, Location Header and Card Location data are displayed in English in the Russian User Interface.
V7.8.0
BRIDGE-1518
Software Version
Virtual Meeting Room call from SIP RealPresence Mobile or Desktop is set up with Subscribe/Notify Message due to “isfocus" in "200 OK" Message returned by RMX. Conference Mode: AVC only.
V7.8.0
BRIDGE-1529
Partners - Microsoft
HDX endpoints disconnected from the conference after 10 to 20 minutes, when the RMX is configured with FQDN address and the Lync server is working with load balancing and holds more than one address. To ensure that endpoints such as HDX remain connected to the conference for its duration when the RMX is configured with FQDN address and the Lync server is working with load balancing and holds more than one address, the following two flags must be manually added and set to: * MS_KEEP_ALIVE_ENABLE = YES * SIP_TCP_PORT_ADDR_STRATEGY = 1 (default setting)
V7.8.0
BRIDGE-1538
Video Zoomed-in video received by endpoints in H.323 Video Switching, H.264 SD 30 conference.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 99
BRIDGE-1543
General When attempting to create a 64kbps AVC only conference profile the following message is always displayed: The selected Conference Line Rate is too low to support the selected Content LIne Rate. Click Cancel and reconfigure either of the Line Rates or click OK to return to the default Content Setting.
V7.8.0
BRIDGE-1560
Partners - Microsoft
When a Lync client dials in using TCP only the Channel Status - Advanced tab in the participant properties window shows it is connecting using UDP instead, even though it is really connecting using TCP.
V7.8.0
BRIDGE-1581
Resource Capacity
In a 4096k confernece on an RMX 4000 with and MPMx card, a dial-out HDX connecting with 1080p uses 8 ports from the resource pool instead of 6 ports as was the case in RMV Version 7.7.
V7.8.0
BRIDGE-1593
RMX Web Client
In the Profile Gathering Settings dialog box, some fields are displayed in English in the Russian User Interface.
V7.8.0
BRIDGE-1598
RMX Web Client
Destination field names are incorrect in the Administration, Tools, Logger Configuration dialog box in the Russian User Interface.
V7.8.0
BRIDGE-1601
Multilingual When using the RMX Manager or Web Client in Russian, the right-click menu on a group in the address group shows several items not translated into Russian.
V7.8.0
BRIDGE-1608
Multilingual The, "Import System Flags" and, "Export System Flags" windows in the RMX Manager and the Web Client are not translated into Russian.
V7.8.0
BRIDGE-1609
RMX Web Client
Information Collector, when interrupted, displays Collection Info Status message in English in the Russian User Interface.
V7.8.0
BRIDGE-1710
Content A RealPresence Desktop endpoint connected at a line rate of 128kbps to SVC conference cannot receive video after sending content.
V7.8.0
BRIDGE-1813
Partners - Microsoft
When the CAC_ENABLE flag is set to "YES", only13 endpoints can connect to the conference.
V7.8.0
BRIDGE-1952
Video Image distortion develops in static scene after several minutes in 3Mb, 1080p, Sharpness call on HDX to RMX using MPMx. LPR, AES are off.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 100
BRIDGE-1977
Interoperability When an RMX dials out to an Aethra X7 endpoint, the Aethra requires 20 seconds to receive audio and video.
V7.8.0
BRIDGE-2003
Cascading An ISDN Cascading Link cannot be connected to cascading conferences.
V7.8.0
BRIDGE-2029
General In a Hot Backup configuration, an AVC call is present in a restored SVC conference on the Slave MCU following a 5 minute freeze after the Master MCU is rebooted.
V7.8.0 SVC endpoints should dial-in to the SVC-based conference after a Hot Backup event.
BRIDGE-2044
Security When using the White List for IP addresses access is allowed to the Shelf Management page from an IP not on the white list.
V7.8.0
BRIDGE-2069
Content An ISDN endpoint connected to a conference via RMX gateway call, does not receive content that is sent from an IP endpoint that is using the People+Content protocol.
V7.8.0
BRIDGE-2071
Gateway When a VSX 7000A ISDN endpoint connects via gateway to a conference running on RMX 2000 with an MPMx card, the video frame rate is very low.
V7.8.0
BRIDGE-2089
General In the Management Network Properties, Whitelist tab, when the Enable Whitelist field is selected and then switching from IPv4 to IPv6, you cannot Login to the RMX.
V7.8.0
BRIDGE-2098
FECC In a 1920Kbps conference with three dial-out 1080p60Mars endpoints, when using FECC to control Speaker's camera, the Far button with arrows and Zoom In/Out do not function.
V7.8.0
BRIDGE-2101
FECC In a 1920Kbps conference with three dial out 1080p60Mars endpoints, when using FECC to control Speaker's camera, the Far button with arrows and Zoom In/Out do not function.
V7.8.0
BRIDGE-2107
SIP An RMX 2000 with 32 TCP and 16 UDP fixed ports configured, a second SIP endpoint fails to connect after the first SIP endpoint connected (each SIP endpoint requires a minimum of 2 TCP and 8 UDP ports) as there are not enough resources for the additional BFCP port that is required.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 101
BRIDGE-2165
RMX Web Client
When changing the participant's Role using "Change to Regular Participant" or "Change to Chairperson", the change in role icon display in the RMX Web Client may take up to 2 minutes.
V7.8.0
BRIDGE-2197
General In a conference with one participant with recording enabled on an RMX 2000 with an MPM+ card the participant cannot hear the welcome music.
V7.8.0
BRIDGE-2198
IVR When the first participant connects to a conference running on an RMX 2000 with an MPM+ card with roll call enabled and records his/her name, when that participant disconnects from the conference, other participants that are also connected hear a cut off message ("left the conference") without the first participant's recorded name.
V7.8.0
BRIDGE-2201
Partners - Microsoft
Call Admission Control (CAC) calls from HDX get disconnected after approximately 1 hour when both SIP_TCP_PORT_ADDR_STRATEGY and MS_KEEP_ALIVE_ENABLE System Flags are set to NO.
V7.8.0 Set both flags SIP_TCP_PORT_ADDR_STRATEGY and MS_KEEP_ALIVE_ENABLE to YES.
BRIDGE-2253
Partners - Microsoft
When an HDX or Lync 2010 client using RTV connect to an unecrypted conference with a bit rate of 384K the video lags behind the audio.
V7.8.0
BRIDGE-2297
General When the TERMINATE_CONF_AFTER_CHAIR_DROPPED flag is set to yes, in a conference with 2 participants, if one is changed to chairperson and is disconnected the other participant remains connected to the conference although the conference should have been terminated after the chairperson disconnected.
V7.8.0
BRIDGE-232
Video When the camera of a 1080p 60-enabled endpoint connected at a resolution of 1080p60 is quickly moved, the top half of the video is sometimes not synced with the bottom half.
V7.8.0
BRIDGE-2347
Resource Capacity
When the system flag SEND_SIP_BUSY_UPONRESOURCE_THRESHOLD is enabled, and Port Gauge is 80% after many audio endpoints dial-in, a notification that the audio threshold has been exceeded is not sent.
V8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 102
BRIDGE-241
Partners - Microsoft
When a Lync endpoint that is connected to a Meeting Room running on the RMX escalates the call from audio to video and back to audio many times within a short period, all the Lync participants disconnect from the conference.
V7.8.0
BRIDGE-2556
General When creating a new conference Profile, after selecting SVC only and accessing the line rate drop down list includes the unsupported line rates of 68 & 96 Kbps.
V8.0
BRIDGE-295
Video Participants in Telepresence conference configured with Auto Layout, Gathering and Telepresence Mode set to Auto receive Gathering slide followed by 1+4 layout with black background as soon as ITP room connects.
V7.8.0
BRIDGE-300
Multilingual When using the RMX Manager or Web Client in German, the text next to the drop down for encryption options in the advanced tab of Conference Profile properties uses two lines. The second line is cut off. .
V7.8.0
BRIDGE-3212
H.323 The RMX does not support SirenLPR when the conference rate is set to 128kbps during an H.323 call.
V8.1
BRIDGE-327
Interoperability RSS 2000 Connection H.323 Link Status pane, E.164 column displays RMX Conference ID instead of E.164 data when recording RMX conference that is enabled to start recording immediately.
V7.8.0
BRIDGE-329
IVR When DTMF codes have been entered by the participants, the volume of the IVR Message may be suppressed or the message may be cut.
V7.8.0
BRIDGE-336
Interoperability During a CP conference after a VVX 15000 endpoint registered to a FED14 Lync FE server is muted and then unmuted, the endpoint cannot receive audio or video.
V7.8.0
BRIDGE-3374
General During conference on RMX 2000 with 40 or more connected participants, the following ASSERT may occur: File:MccfRxSocket.cpp Line:169 Code:1
V8.1.1
BRIDGE-3388
RMX Web Client
After setting the SESSION_TIMOUT_IN_MINUTES flag to 5 minutes, the system in ultra secure mode does not log you out as would expected using the new time value.
V8.1
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 103
BRIDGE-341
FECC It is possible to choose an empty layout cell for far camera control.
V7.8.0
BRIDGE-3684
General Sometimes RMX doesn't forward the content stream to the content receivers.
V8.1.7, V8.3
BRIDGE-369
General RMX does not detect non standard DTMF tones from Panasonic KX-TS2565RU phones.
V7.8.0
BRIDGE-3699
Interoperability A CTS could not be put on hold and resume when music from the CUCM was on hold.
V8.1.1
BRIDGE-387
IVR In the IVR Services when replacing/changing a music file and clicking on Play, the music file does not start.
V7.8.0
BRIDGE-400
General In Multiple Networks Configuration, Recording Links use the default Network Service to connect to conferences, therefore the recording system must be defined on the default network Service to enable the recording.
V7.8.0
BRIDGE-408
General A Lync endpoint can call and connect to a meeting room that is available in his buddy list even though the meeting room is unavailable/offline and has SIP registration disabled in the Conference Profile.
V7.8.0
BRIDGE-410
Software Version
VVX dial in participant's IPAddress/Phone field in Participants List field is listed as 0.0.0.0 instead of the VVX's actual IP Address or phone number.
V7.8.0
BRIDGE-4113
Interoperability In a conference with 2 CTS systems with music provided by CUCM, when one of the CTS systems was put on hold and then resumed, it was disconnected from the conference.
V8.1.1
BRIDGE-418
General When upgrading the RMX and changing from Event Mode to CP mode, a conference template which is a mismatch for CP mode can be scheduled as a reservation, even though it cannot be used to start a conference immediately.
V7.8.0
BRIDGE-4212
General When the SIP_ENCRYPTION_KEY_EXCHANGE_MODE flag is set to SDES, endpoints that attempt to hold and then resume are disconnected.
V8.1.1
BRIDGE-4296
General In a conference with 1 HDX connecting using SIP and 1 CTS using TIP, when the HDX was the chairperson the *5 DTMF code (mute all except me) did not mute the CTS.
V8.1.1
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 104
BRIDGE-433
Interoperability When the RMX and HDX endpoints are registered with a CMA, after dialing out from an HDX endpoint a numerical error message appears.
V7.8.0
BRIDGE-440
Video Auto Scan does not work when Same Layout is active.
V7.8.0
BRIDGE-442
Cascading During a Cascaded conference, the cascaded link sometimes send a "need help" message to participants.
V7.8.0
BRIDGE-443
General After changing the conference name and the Profile to the SIP Registration profile and then clicking OK, the changes do not take affect nor are they registered.
V7.8.0
BRIDGE-447
Resource Capacity
Two VSW conferences each with participants are all located on one MPMx card, when it is expected that each conference and its participants should be located on separate MPMx cards.
V7.8.0
BRIDGE-450
Diagnostics When the RMX is in a Diagnostic mode, in the Hardware Monitor, Loop Tests fail on the ISDN card.
V7.8.0
BRIDGE-458
Diagnostics When the RMX is in Hardware Monitor - Diagnostic mode, Loop Tests fail on the ISDN card.
V7.8.0
BRIDGE-4651
MPM Card After a call started, network traffic meant for the MPMx card is sent to all network ports on the subnet.
V8.1.4
BRIDGE-467
Upgrade Process
After upgrading from version 7.6.1.136 to 7.7.0.41, an activation key is not requested.
V7.8.0
BRIDGE-4674
General When two participants simultaneously attempt to enter an Entry Queue with the same PIN are rejected.
V8.1.1
BRIDGE-478
General When there are more than one conferences configured to Video Quality Optimized" or H.323 running simultaneously, some dial-out participants will not connect to a conference, receiving a "resource deficiency - 0" in the Call Disconnection Cause field in the endpoint Properties box.
V7.8.0
BRIDGE-4845
Interoperability A GS300 endpoint view pixelated video and encounters audio loss on a WAN network with considerable packet loss.
V8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 105
BRIDGE-486
Video When running a conference set to Same Layout, Auto layout and Polycom skin on the RMX whose resolution configuration for SD is set to 128Kbps, one of the layout cells displayed on some of the endpoints is distorted.
V7.8.0
BRIDGE-4930
Interoperability When an OTX 300 endpoint dials into a Virtual Meeting Room, there are problems with the OTX video layout.
V8.1.1
BRIDGE-4959
Partners - Microsoft
When the Network Service is configured to both IPv4 and IPv6, a dial-in Lync 2013 Client cannot connect to conferences. Note: the RMX does not support Lync 2013 clients with IPv6.
V8.1.4
BRIDGE-498
Audio During a video conference call with IBM ST clients, when 2 clients are placed on hold and reconnect, they cannot hear audio.
V7.8.0
BRIDGE-501
RMX Manager RMX Manager failed to install from login page.The request is aborted with the message: "Could not create SSL/TLS secure channel".
V7.8.0 1. Install RMX Manager before initiating Secured Communications Mode. 2. Install from a network 3. Install locally from RMX Manager folder
BRIDGE-503
General When configuring the RMX with Multiple Network Services and defining the DNS for each Network Service, after RMX reset the Lync client cannot connect to the RMX as it cannot resolve the RMX address using the configured DNS.
V8.2
BRIDGE-505
Partners - Microsoft
The aspect ratio of the video display on the Lync client running on a MAC workstation is always 4:3 and does not change according to the actual screen aspect ration (16:9), after changing the Video layout from a big screen to a smaller screen.
V7.8.0
BRIDGE-512
RMX Manager In a video Switching conference, when forcing a participant to the main window, whenever the active speaker changes, the forcing indication in the RMX web client/RMX Manager is canceled and replaced by the "Auto" indication.
V7.8.0
BRIDGE-516
Video Gathering phase slide is displayed at 50% transparency (instead of solid background) on ITP endpoints.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 106
BRIDGE-524
SIP When multiple Network Services are configured on RMX with an MPM+ card, each of which is registered with a SIP registrar, and one of those SIP registrars has a problem, an alarm will be raised but it will not specify the network service or the SIP registrar.
V7.8.0
BRIDGE-5252
Resource Capacity
During a mixed mode (AVC&SVC) conference when an endpoint switches from audio to video and then back again, additional ART resources are used, but later when reverting to audio these video resources remain occupied.
V8.1.4
BRIDGE-5280
Video In a CP conference with a Lync client connected, the client's video jumps between HD and QCIF VGA.
V7.6.1
BRIDGE-531
Gateway In Gateway Calls, a call is disconnected and a ‘call failed’ message is displayed when dialing a wrong number. An IVR message to redial the number is not played.
V7.8.0
BRIDGE-5325
Interoperability Green screen is displayed for 2 - 3 seconds when connecting HDX 9000 endpoint to RMX using DTLS Encryption with AES 128 SHA1_80. Call then proceeds normally.
V8.1
BRIDGE-538
Interoperability A Sony PCS-G90 is unable to connect over H.323 to an encrypted conference running on RMX 1500.
V7.8.0
BRIDGE-5396
Interoperability CTS3010 endpoint disconnects after Hold and Resume when Music on Hold is enabled in CUCM.
V8.1.1 Configure SIP trunks from CUCM to Polycom system components with Music on Hold disabled.
BRIDGE-544
Video During a TelePresence conference with OTX systems, after dragging and dropping an OTX 300 endpoint into the conference, the layouts did not display properly.
V7.8.0
BRIDGE-554
ISDN ISDN participants cannot connect to Meeting Rooms running at a line rate of 512, 768, 1024, 1472, or 1920 kbps if they are connected simultaneously or if the interval between the connections is less than 20 seconds.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 107
BRIDGE-556
Interoperability When the RMX is registered with the Broadsoft server, a SIP to H.323 gateway call fails when dialing directly to the destination endpoint.
V7.8.0 Use the Gateway IVR routing method.
BRIDGE-559
Content During a CP conference with dial-in HDX endpoints, after sending content from a desktop, the content displays in a single cell of the CP layout.
V7.8.0
BRIDGE-560
Interoperability On an RMX registered with the RealPresence DMA system (SIP), after an Avaya 10xx endpoints connect with good audio and video, the endpoints suddenly disconnects.
V7.8.0 Not an RMX issue
BRIDGE-563
Content During a TelePresence conference with CTS and HDX conferences, when an HDX sends content the CTS endpoint disconnects and the conference therefore becomes non TelePresence, however the Skin and borders of the previous layout still appear.
V7.8.0
BRIDGE-567
General In an Event Mode conference, after selecting an HDX to be the chairperson, nothing happened when using a PCM remote control to Mute& Block audio / suspend video of the chairperson.
V7.8.0
BRIDGE-590
Interoperability Telepresence server cannot connect to 4mbps, TIP: Video & Content conference on RMX configured as legacy endpoint that doesn't declare TIP compatibility.
V7.8.0
BRIDGE-591
General When selecting one of the last three colors from the Message Overlay color drop down menu, the color selection is not implemented during the conference.
V7.8.0
BRIDGE-593
Video An HDX that connects to a Video Switching High Profile 720p60 will get a frame rate of 25 fps instead of 50/60 fps.
V7.8.0
BRIDGE-5937
UCAPL / JITC / CESC / Q4 2013 - SIP registration failed when RMX in auto configuration for IPv6, OCSP on, IPv6 global responder URL specified.
V8.1.4, V8.3
BRIDGE-594
Interoperability A Telepresene server cannot connect to a 4mb TIP: Video + Content conference on an RMX 1500 with an MPMx card.
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 108
BRIDGE-6017
Software Version
The SAN field, DNS Name (FQDN) in the Create Certificate Request dialog box is not used for Machine Account validation. For example, the RealPresence DMA system will not validate the RMX unless the FQDN field in the User Properties dialog box is correctly filled in.
V8.1.4
BRIDGE-603
Resource Capacity
On an RMX with an MPM+ card set to maximum resolution of HD720, only 19 parties can connect.
V7.8.0
BRIDGE-6037
Software Version
On IPv6 configured RMX, when changing IPv6 Configuration Method from Manual to Auto (Stateless) for IPv6 only RMX, RMX the Internal System Configuration during Startup alarm is displayed with a duration of 10 minutes or longer after system start up.
V8.1.4 Use Manual IPv6 Configuration Method with IPv6.
BRIDGE-606
General Due to the activation of the Information Collector, an RMX 2000 with an MPMx card encounters High CPU usage, and as a result a CP conference with a line rate of 512 Kbps views artifacts in the layout.
V7.8.0
BRIDGE-6176
Video During an H.261/H.263 Protocols enabled Dial-out conference, video fails due to internal MCU errors.
V8.1.6
BRIDGE-626
General When trying to control the conference using PCM via a virtual remote control, some of the PCM options cannot be selected.
V7.8.0
BRIDGE-6275
Interoperability When an RMX dials–out to a Viewstation endpoint, the Viewstation cannot receive content.
V8.1.6
BRIDGE-6345
Audio AVC participant Content audio is also muted by microphone mute setting when dialing into SVC/AVC Mixed mode conference.
V8.1
BRIDGE-643
General When an RMX 4000 with 4 MPMx cards connects to two HDX 7000's using SIP in a 1024 kbps conference set for 1080p they instead connect as 4SIF, but if they connect using H.323 they connect as 1080p.
V7.8.0
BRIDGE-644
Multilingual A number of fields in the RMX Manager and Web Client are not translated into Traditional Chinese
V7.8.0
BRIDGE-6442
Interoperability A VVX 1500 endpoint registered with the RealPresence DMA system does not see video after the RMX dials out to the endpoint.
V7.7
BRIDGE-6448
Video When the VMR profile is set to prefer TIP and LPR enabled, after connecting to the conference, a SIP RPX has video problems.
V8.1.1
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 109
BRIDGE-645
General RMX 4000 prompts for an extra reset during "Restore Factory Defaults" procedure (after insertion of the Activation Key). Reset should only be performed after the Fast Configuration Wizard has completed.
V7.8.0
BRIDGE-6467
General After Lync Clients or GS endpoints dial-in into a conference, the call reaches the RMX but a core dump is created and the RMX MPMx card crashes.
V8.1.7
BRIDGE-647
General After adding an activation key on the RMX 1500, an error stating: "expired" appeared, when it should have stated "incompatible key".
V7.8.0
BRIDGE-6483
General When PCM is enabled, after entering DTMF code *78, the PCM Password screen does not appear.
V8.1.7
BRIDGE-649
Interoperability When the RMX is used as ISDN-Gateway (H.320) with OpenScapeVoice (Siemens SoftMCU), after connecting Tandberg MXP6000 & Tandberg Edge95 ISDN endpoints, Sip endpoints hear only audio and cannot view the Welcome screen.
V7.8.0
BRIDGE-6490
General Create an ISDN/PSTN Entry Queue enabled conference in the conference properties, after conference start ISDN/PSTN is not enabled.
V8.1.6
BRIDGE-6492
Interoperability When the RMX is used as ISDN-Gateway (H.320) with OpenScapeVoice (Siemens server), after connecting Tandberg MXP6000 & Tandberg Edge95 ISDN endpoints, Sip endpoints hear only audio and cannot view the Welcome screen.
V7.8.0
BRIDGE-6492
Interoperability CLONE -RMX as ISDN Gateway - No StartScreen shown in ISDN to SIP transit scenario
V7.8.0
BRIDGE-650
General After moving participants between conferences with different default line-rates, the participant's line-rate does not match that of the destination conference. The result is that content cannot be send to the new conference.
V7.8.0
BRIDGE-651
Content Shared H.263 Content is received slowly on RealPresence Mobile client.
V7.8.0
BRIDGE-6511
Video After Lync Clients dial-in into a meeting room, if there is inadequate network bandwidth the RMX MPMx card crashes and a core dump is created.
V8.1.7
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 110
BRIDGE-6511
Video CESC / Microsoft / Q3 2013 / RRI / Lync 2010 - RMX CAC - Core dump and media card crash on a dial in to RMX meeting room when sufficient bandwidth is unavailable
V8.1.7
BRIDGE-6518
Content A CSS client cannot share and receive content while LPR is enabled in the conference running on an RMX.
V8.1.7
BRIDGE-6519
Content On a conference set to LPR and content, the CSS clients sends content to the RPD endpoint at 380Kbps, however the RPD negotiated content line rate settings should be set to 192 Kbps.
V8.1.7
BRIDGE-6560
Interoperability ITP endpoint’s Slave endpoints do not connect in RMX dial out call.
V7.8.0
BRIDGE-6579
Content When an RPD is sharing content and applications, VVX endpoints failed to receive content.
V8.1.7
BRIDGE-6600
Content RPD/RPM endpoints cannot view content due to minimum H.264 content rates as defined in three flags: H264_HD_GRAPHICS_MIN_CONTENT_RATE; H264_HD_HIGHRES_MIN_CONTENT_RATE, H264_HD_LIVEVIDEO_MIN_CONTENT_RATE.
V8.1.7 Change the flags _MIN _CONTENT_RATE settings to 0.
BRIDGE-6605
General Rarely, HDX endpoint with TIP enabled is connecting with problem and transmitting video at a resolution of 1080p instead of 720p.
V8.1.6
BRIDGE-6651
Interoperability In dial-out Virtual Meeting Room with RPD and ITP endpoints connected, the ITP room only views video on its center screen.
V8.1.1
BRIDGE-6686
General Ongoing conference cannot be deleted or users cannot be removed from the conference. Frequency: Rare.
V7.6.1
BRIDGE-670
Software Version
Manual connection can take up to 30 seconds to begin in 2048kbps conference, with manual dial out to over 80 participants.
V7.8.0
BRIDGE-677
Video An HDX 9004 connecting at a maximum of 786k to an RMX 2000 with MPMx card may display green splotches on the Welcome slide.
V7.8.0
BRIDGE-6786
Video A Cisco SX20 endpoint version 5.1.x registered with the Cisco CUCM receives "No Incoming Video" when connecting to a Conference via the RealPresence DMA system.
V8.1.7 Upgrade the endpoint to version 6.1.x.
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 111
BRIDGE-6788
IVR When using an External Control IVR service for an AT&T RealPresence DMA system VEQ callflow on the RMX, the MCCF playCollect dialog-starts the collect timer at the start of the play rather than at the completion of the play.
V8.1.1
BRIDGE-6809
Interoperability With TIP enabled, calls connect, then immediately disconnect on Group Series endpoint registered to VCS Expressway SIP Registrar Server. When TIP is disabled, calls connect as expected.
V8.1.6
BRIDGE-683
Interoperability When connecting an endpoint to a 768 Kbps CP conference using HD720p (High Profile H.264 disabled on endpoint), the endpoint still connects using H.264.
V7.8.0
BRIDGE-6854
Interoperability When HDX with TIP enabled and registered to CUCM connects at a low line rate (768kbps) so it is forced to use SIP, it cannot receive content.
V8.1.6
BRIDGE-6862
Interoperability Lifesize endpoint registered to the RealPresence DMA system cannot connect to a secure conference.
V8.1.6
BRIDGE-6890
Software Version
C60 may be connected with a problem or disconnected from the Encrypted conference when performing hold and resume when connected to the conference using the last free video resource.
V8.1.6
BRIDGE-6891
PCM PCM is not supported in this version. V8.1
BRIDGE-7056
Interoperability CTS endpoint disconnects from the conference after the performing hold and resume while the conference was locked/ secured by the conference chairperson.
V8.1.6
BRIDGE-706
General An unclear message "No utilizable unit for audio controller" is displayed when removing all Media cards from the RMX.
V7.8.0
BRIDGE-7105
Real time problems above 9 SD EPs in a single Netra DSP
V8.1.8 To enable 12 CIF/SD ports per Netra unit add the following flag: Flag name: LIMIT_CIF_SD_PORTS_PER_NETRA_UNIT Value: 'NO' Non visible
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 112
BRIDGE-711
Upgrade Process
On the RMX 2000/4000 with an ISDN card installed, after configuring the IP Fast Configuration Wizard, the system requests a reset and not to configure the ISDN Service.
V7.8.0
BRIDGE-7125
Interoperability C60 endpoint does not receive content when ICE is enabled.
V8.1.6
BRIDGE-7202
Software Version
After Hold/Resume, EX90 endpoint does not continue receiving content. Problem occurs after successfully negotiating encryption and connecting to an EWP or Encrypt All VMR directly, or via VEQ.
V8.1.6
BRIDGE-7232
General When a chairperson or participant accessing a password enabled Virtual Entry Queue and Virtual Meeting Room enters the conference, when placing the CTS endpoint’s video on hold and resume, the CTS endpoint disconnects.
V8.1.6
BRIDGE-7265
Video A Lync endpoint encountered video freezes due to Video DSP crashes.
V8.1.6
BRIDGE-7271
Software Version
Content is not received by HDX System connected to unsecured, CP conference in Prefer TIP, VMR.
V8.1.6
BRIDGE-7284
Software Version
OTX System has frozen video, then drops but does not disconnect. Occurs after connecting with problems using UDP trunk to secured, CP conference in Prefer TIP, VMR.
V8.1.6
BRIDGE-7296
Software Version
LifeSize220 cannot move from VEQ to VMR. LifeSize220 endpoint registered with RealPresence DMA system using TLS, when manually dialing into unsecure VEQ, experiences dropped call after entering the conference ID for the unsecured VMR.
V8.1.6
BRIDGE-7299
General During an audio only conference with two participants an assert occurred.
V8.1.6
BRIDGE-7348
General A conference is set for participants to wait for the chairperson to enter/activate using the chairperson password, however a CTS endpoint manages to gain access to the conference without the chairperson being present.
V8.1.6
BRIDGE-7367
Interoperability When a CTX or TX endpoint registered to CUCM is connected to a TIP-enabled conference with Content places the call on Hold, it sees a blank screen while the other endpoints see their self-view.
V8.1.7
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 113
BRIDGE-7421
Video During a conference with content, after initiating a Hold/Resume video on a TX9000 endpoint, the TX9000 reconnected to the conference as SIP participant and all its screens showed up black.
V8.1.6
BRIDGE-7425
Interoperability When an RPD endpoint sends content, only a black screen can be viewed.
V8.1.6
BRIDGE-7426
Interoperability When an RPD endpoint send content, a CTS500 endpoint cannot view the content.
V8.1.6
BRIDGE-7444
Video During a Virtual Meeting Room, after 20 times of Video Hold/Resume being initiated, the CTS 1300 disconnected.
V8.1.6
BRIDGE-7450
General When using WinSCP to connect to the RMX, a Core Dump generated MFA and conference participant files.
V8.1.6
BRIDGE-753
Resource Capacity
On an RMX 2000 running a 384 Kbps conference with a large number of CIF participants, the system registered a high system CPU usage assert.
V7.8.0
BRIDGE-7538
Interoperability With endpoints registered with the RealPresence DMA system, FECC is unavailable on H.323/SIP HDX 8000 endpoints.
V8.1.6
BRIDGE-7540
Diagnostics Diagnostic doesn't work when the system is not in Ultra Secure Mode. (By design, Diagnostics Mode does not function when the RMX is in Ultra Secure Mode.)
V8.2
BRIDGE-7540
Diagnostics 8.2.0.35/44 >> rescue fialed V8.2
BRIDGE-7549
Security System Rescue procedure using the Standby button fails when the system is in Ultra Secure Mode resulting in the RMX remaining in Startup mode.
V8.1.4 Workaround: Reset the RMX to Factory Defaults to disable ULTRA_SECURE MODE before performing the System Rescue procedure.
BRIDGE-7558
SIP During Room-Switched Conferences, the RMX should use uses CNAME and not SIP user name to define the video layout order.
V8.1.6
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 114
BRIDGE-7568
Interoperability When TIP Compatibility: "Prefer TIP" is enabled in the Profile - Advanced tab and Send Content to Legacy endpoints is disabled for the conference, dial-in Lync Clients cannot view content.
V8.1.6
BRIDGE-7575
IVR After a chairperson hears the IVR prompt "please wait for chairperson” and he/she enters the DTMF code *78, the entered DTMF code is ignored and the prompt "please wait for chairperson” is repeated once again. The DTMF code *78 should be recognized and the IVR prompt "for chairperson services, enter the # key" should be played.
V8.1.6
BRIDGE-7604
General An error message saying, "Failure Status" is sometimes shown when attempting to save a conference template.
V8.2 Reset the RMX.
BRIDGE-764
Software Version
Gathering slide is not displayed on OTX Room System when dialing into RMX MPMx conference.
V7.8.0
BRIDGE-7738
Resource Capacity
The RMX 2000 upgrade procedure from Version 8.2.0.25 to 8.2.0.66 fails because of insufficient MCU memory.
V8.2
BRIDGE-775
RMX Web Client
When a Lync endpoint using SIP is muted during a CP conference, there is no indication in RMX Web Client that the endpoint is muted.
V7.8.0
BRIDGE-7779
RMX Web Client
Beginning with version 8.1 the functionality of the MS_KEEP_ALIVE_ENABLE System Flag has been replaced with the following System Flags: SIP_TCP_KEEP_ALIVE_TYPE and SIP_TCP_KEEP_ALIVE_BEHAVIOR
V8.2
BRIDGE-7797
Audio When a H.323 Group Series endpoint dials out to a SIP HDX endpoint via an RMX with a Gateway Profile set to 'encrypt when available', the HDX endpoint does not receive audio.
V8.2
BRIDGE-7869
General Polycom CMAD and the Telepresence M100 endpoints fail to share content with Group Series endpoints after dialing in over SIP to a mixed CP and SVC conference.
V8.2
BRIDGE-7884
Interoperability During a CP conference, Radvision Scopia XT1000 & XT5000 endpoints registered to the RealPresence DMA system and connected via SIP share content via the video channel and not the content channel.
V8.2
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 115
BRIDGE-7885
Interoperability During a CP conference running at a line rate of 4MB, Tandberg 1700 (MXP) endpoints registered to a RealPresence DMA system fail to receive content from a Tandberg Edge95 (MXP) endpoint.
V8.2
BRIDGE-7915
General Intermittently, lip-sync occurs when content is shared in a mixed CP and SVC conference.
V8.2
BRIDGE-793
Interoperability When CTS 3000 connects as dial in through RealPresence DMA system, the Gathering Slide on CTS 3000 endpoint flickers and displays artifacts. Conference is CP, gathering enabled, TIP; Video &Content at 2560kbps, 1080p resolution with No Encryption.
V7.8.0
BRIDGE-7958
Interoperability Group Series endpoints registered to a Siemens server fail to receive content when connected over SIP to an encrypted conference.
V8.2
BRIDGE-7959
Interoperability Content cannot be seen on a VVX endpoint when connected to an encrypted conference running on an RMX that is registered with the Siemens server.
V8.2
BRIDGE-8037
Video CESC / Microsoft / Q4 2013 / SoftRPP / Lync connects with problem on a dial out from softmcu
V8.2
BRIDGE-8039
General CESC / Microsoft / Q4 2013 / SoftRPP / SoftMCU – RMX disconnecting the call while dialing out to CX500 and CX600 endpoints
V8.2
BRIDGE-8134
Partners - Microsoft
A beep is heard at 10 second intervals on Lync endpoint connected to Meeting Room with Recording Link enabled. RMX has ICE enabled. Conference line rate is 3074K. Encryption is ON.
V8.2
BRIDGE-82
SIP In a SIP over UDP conference with 2 RealPresence Mobile endpoints and 3 RealPresense Desktop endpoints, the first RealPresense Mobile and RealPresense Desktop endpoints connected with 10% packet loss both uplink and downlink. They also displayed a 1x1 layout, even though all the other endpoints displayed the correct layout. When those endpoints disconnected and reconnected using SIP over TCP the layout was displayed correctly.
V7.8.0 Use TCP for SIP instead of UDP.
BRIDGE-8222
Interoperability CTS 3010 endpoints sharing content during a TIP-enabled conference experience 'smoky' video for 1-2 minutes.
V8.2
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 116
BRIDGE-8229
Video Frequent layout changes in one conference can cause video jitter in another conference hosted on the same MCU.
V8.2
BRIDGE-8244
CLONE - CLONE - Conference rate 256, max receive call speed 128 on GS, call failed
V8.1
BRIDGE-8352
ProdSec/MSM UCAPL: PSO – Hold/Resume from Nortel 1140 with 'Music on Hold' enabled results in one way audio – then conference drops
V8.1.4
BRIDGE-8393
CLONE - CESC / CISCO / Q4 2013 - HDX is disconnecting from RMX Conference with 256 bit rate.
V8.2
BRIDGE-8396
CESC / Q4 2013 Pretest / Q4 2013 TestPass1 / Cisco POCN / NGB Pretests / RMX4000 / RMX1800 Poor Video seen in V+C CP call with CTS3010 and TX9000
V8.3
BRIDGE-841
IP When IPv6 only is enabled in the Management Network Services - IP tab, the RMX Web Client displays the "Browser environment error. Please close and reopen all browser sessions". .
V7.8.0 Reset the RMX
BRIDGE-842
SIP When muting a SIP participant during an ongoing conference, the mute participant icon does not appear in the Participants pane of the RMX Client/RMX Manager.
V7.8.0
BRIDGE-847
SIP SIP Registration status is listed as Not Configured although SIP Registration is enabled in the conference profile. SIP endpoints do connect.
V7.8.0
BRIDGE-86
General In an SVC dial-in conference with 8 endpoints using SIP over UDP some endpoints may not update the layout in bad network connections.
V7.8.0 Use SIP over TCP instead of UDP.
BRIDGE-925
Video When the Telepresence Mode is enabled in the Conference Profile, conferences are able to start even though the flag: "ITP_CERTIFICATION" is set to NO. This flag should disable Telepresence features in the Conference Profile.
V7.8.0
BRIDGE-948
Multilingual The RMX Time menu option was not properly translated in Russian. The user interface in Russian displays the menu item for RMX Time, which does not contain the word, "RMX", although it is included for other languages,
V7.8.0
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Corrections and Known Limitations
Polycom, Inc. 117
BRIDGE-9513
Video If a Lync participant dials in to a conference using a low line rate (such as 256 kbps) from a quad-core laptop, the resolution of far-end video may change sometimes.
V8.2 Dial in using a line rate higher than 256 kbps.
BRIDGE-964
General In the Network Traffic Capture (Administration-->Tool-->Network Traffic Capture) pane select Start Network Traffic Capture. No network traffic capture file of Central Signaling (CS) created.
V7.8.0
BRIDGE-976
IVR When two Avaya 1XC Softphone endpoints join a conference, the IVR Service "first to join conference" music continues to play as if there is just one person in the conference.
V7.8.0
BRIDGE-9870
Content In a conference with the following content settings:
H.264 Cascade
SVC Optimized
H.264 High Profile
1080P30 High Profile
While a Polycom RealPresence Group system is sharing content, if another RealPresence Group system starts content sharing also, endpoints without H.264 High Profile Capacity (such as Polycom HDX systems) may wait several seconds before they can display content smoothly.
BRIDGE-9871
Hardware Performance >> NGB >> SVC load test >> 8.3.0.71 >> not able to see video after recovery in SVC encrypted call
V8.3
BRIDGE-9695
Video During a conference (hosted by a Polycom RMX 1800 system) among two Lync participants and a Polycom RealPresence Group participant, if one Lync participant mutes local video, his/her video layout shows one video cell, instead of two.
BRIDGE-9997
Interoperability GA - 8.3 >>Lync 2013>> First Lync participants see artifacts when connecting to conference
V8.3
BRIDGE-4756/
BRIDGE-4754
General An HDX connecting using TIP via a RealPresence DMA system was unable to move from an Entry Queue to a Meeting Room.
V8.1.1 Not RMX issue, Endpoint Issue
VSGNINJA-1214
Video In a CP & SVC mixed conference, if you dial in with a Polycom VSX system using SIP protocol, sometimes, you cannot receive smooth video.
Dial in using H.323 protocol.
Version 8.3 Known Limitations
Issue ID Category DescriptionFound
in Version
Workaround
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 118
Troubleshooting Instructions
Collaboration Server Web Client Installation - Troubleshooting InstructionsIf a Browser Environment Error occurs, close all the Internet Explorer sessions and reconnect to the MCU.
If the problem persists, you can run the Automatic Troubleshooting Utility or perform the Troubleshooting Procedures manually.
The Manual Troubleshooting Procedures include several procedures that can be performed in order to solve the connection error. At the end of each procedure, check if you can connect to the MCU and if the problem persists, perform the next procedure.
The following troubleshooting procedures can be performed manually:
Procedure 1: Ending all Internet Explorer Sessions
Procedure 2: Deleting the Temporary Internet Files, Collaboration Server Cookie and Collaboration Server Object
Procedure 3: Managing Add-ons Collisions
In Secured Mode (https://), the DNS name specified in the RMX’s Certificate must correspond with that of the DNS Server used by the Client that is connecting to the RMX.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 119
Procedure 4: Add the Collaboration Server to the Internet Explorer Trusted Sites List
Procedure 5: Browser Hosting Controls (Optional)
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 120
Procedure 1: Ending all Internet Explorer Sessions
In some cases, although all the Internet Explorer sessions were closed, the system did not end one or several IE processes. These processes must be ended manually.
To end all Internet Explorer sessions:
Start the Task Manager and click the Processes tab.
1 Select an iexplore process and click the End Process button.
2 Repeat this process for all iexplore processes that are currently active.
3 Close the Windows Task Manager dialog box.
4 Open the Internet Explorer and connect to the MCU.
5 If the problem persists, continue with Procedure 2.
Procedure 2: Deleting the Temporary Internet Files, RMX Cookie and RMX Object
If at the end of Procedure 1 the error message is still displayed, and you cannot connect to the MCU, perform the following operations:
Delete the Temporary Internet files
Delete the RMX/Collaboration Server Cookie
Delete the RMX/RMX ActiveX Object
Deleting the Temporary Internet Files
To delete the Temporary files:
1 In the Internet Explorer, click Tools > Internet Options.The Internet Options dialog box opens.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 121
2 In the Browsing history pane, click the Delete button.
The Delete Browsing History dialog box opens.
3 It is recommended to delete only the Temporary Internet files. By default, the Cookies option is also selected. Clear it if you do not want to clear the cookies from your computer.
4 Click the Delete button.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 122
5 When the process is complete, the system return to the Internet Options dialog box.
Deleting the RMX/Collaboration Server Cookie
To delete the RMX Cookie:
1 In the Internet Options dialog box - Browsing History pane, click the Settings button.
The Temporary Internet Files and History Settings dialog box is displayed.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 123
2 Click the View files button.
The Windows Explorer screen opens, listing Windows Temporary Internet Files.
3 Browse to the RMX/ RMX cookie. The cookie is listed in the format: cookie:user name@RMX/RMX IP address. For example: cookie:[email protected].
4 Right-click the RMX cookie and click Delete.
The system prompts for confirmation.
5 Click Yes.The cookie is deleted.
6 Close the Windows Explorer screen.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 124
Deleting the RMX/Collaboration Server ActiveX Object
To delete the RMX/RMX ActiveX Object:
1 In the Temporary Internet Files and History Settings dialog box, click the View objects button.
The Windows Explorer screen opens, listing the Windows Downloaded Program Files.
2 Right-click the EMA.ClassLoader.dll and then click Delete.
The system prompts for confirmation.
3 Click Yes.The RMX object is deleted.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 125
4 Close the Windows Explorer screen.
5 In the Temporary Internet Files and History Settings dialog box, click OK.
6 In the Internet Options dialog box, click OK to close it.
7 Close the Internet Explorer session and reopen it.
8 Connect to the RMX.
If the problem persists, continue with Procedure 3.
Procedure 3: Managing Add-ons Collisions
In some cases, previously installed add-ons, such as anti virus programs can create collisions between applications and prevent the installation of a new add on. Disabling these add-ons may be required in order to install the RMX Web Client.
To disable an add-on:
1 In the Internet Explorer, click Tools > Manage Add-ons.The Manage Add-ons - Toolbars and Extensions dialog box opens.
2 Scroll to the add-on to disable (for example, the anti virus add-on), right-click it and then click Disable.
Alternatively, select the add-on and click the Disable button.
3 Click the Close button to close this dialog box.
4 Connect to the RMX.
If the problem persists, continue with the Procedure 4.
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 126
Procedure 4: Add the Collaboration Server to the Internet Explorer Trusted Sites List
In some cases, local security settings may prevent Internet Explorer from accessing the RMX.
To add the RMX to the Internet Explorer Trusted Sites list:
1 In the Internet Options dialog box, click the Security tab.
The Security tab is displayed.
2 Click the Trusted Sites tab.
3 Click the Sites button.
The Trusted sites dialog is displayed.
4 If the Collaboration Server (RMX) is using Secure Mode:
a In the Add this website to the zone: field, enter, “https://” followed by the IP address or the DNS name of the Collaboration Server (RMX).
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 127
b Click the Add button.
c Click the Close button.
5 If the Collaboration Server (RMX) is using Standard Security Mode:
a In the Add this website to the zone: field, enter, “https://” followed by the IP address or the DNS name of the Collaboration Server (RMX).
b Click the Add button.
c Clear the Require server verification (https:) for all sites in this zone checkbox.
d Click the Close button.
Procedure 5: Browser Hosting Controls (Optional)
If the Collaboration Server (RMX) Web Client does not load and run after Procedures 1-4 have been performed, the reason may be that .NET Framework 4 or higher is running on the workstation with Managed Browser Hosting Controls disabled.
Managed Browser Hosting Controls is an Internet Explorer operating mode required by the Collaboration Server (RMX) Web Client. By default, .NET Framework 4 and higher are not enabled to support Managed Browser Hosting Controls.
Perform Procedure 5 to:
Determine whether .NET Framework 4 or higher is running on the workstation.
Determine whether a 32-bit or 64-bit version of Windows is running on the workstation.
Enable Managed Browser Hosting Controls if .NET Framework 4 or higher is running on the workstation.
To enable Managed Browser Hosting Controls:
1 Determine whether .NET Framework 4 or higher is running on the workstation.
a On the Windows Desktop, click Start.
b In the Start Menu, click Control Panel.
c In the Control Panel, click Programs and Features.
d Inspect the Programs and Features list for the version of Microsoft .NET Framework Client Profile that is installed.
2 Determine whether a 32-bit or 64-bit version of Windows is running on the workstation:
a On the Windows Desktop, click Start.
b In the Start Menu, click Computer.
c In the Computer Menu, System properties and inspect the value of the System type field in the System section
3 Enable Managed Browser Hosting Controls if .NET Framework 4 or higher is running on the workstation.
a Open the Registry.
b Navigate to the Subkey:
32-bit System: HKEY_LOCAL_MACHINE\SOFTWARE\MICROSOFT\.NETFramework
64-bit System: HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Microsoft\.NETFramework
RMX Release Notes Version 8.3 Troubleshooting Instructions
Polycom, Inc. 128
c Add the Dword Value: EnableIEHosting
d Set value of EnableIEHosting to 1.
e Close the Registry.